1.
J Appl Clin Med Phys ; 16(2): 4774, 2015 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-26103165

RESUMO

 The objective of this study was to improve the visibility of anatomical details by applying off-line postimage processing in chest computed radiography (CR). Four spatial domain-based external image processing techniques were developed by using MATLAB software version 7.0.0.19920 (R14) and image processing tools. The developed techniques were implemented to sample images and their visual appearances confirmed by two consultant radiologists to be clinically adequate. The techniques were then applied to 200 chest clinical images and randomized with other 100 images previously processed online. These 300 images were presented to three experienced radiologists for image quality assessment using standard quality criteria. The mean and ranges of the average scores for three radiologists were characterized for each of the developed technique and imaging system. The Mann-Whitney U-test was used to test the difference of details visibility between the images processed using each of the developed techniques and the corresponding images processed using default algorithms. The results show that the visibility of anatomical features improved significantly (0.005 ≤ p ≤ 0.02) with combinations of intensity values adjustment and/or spatial linear filtering techniques for images acquired using 60 ≤ kVp ≤ 70. However, there was no improvement for images acquired using 102 ≤ kVp ≤ 107 (0.127 ≤ p ≤ 0.48). In conclusion, the use of external image processing for optimization can be effective in chest CR, but should be implemented in consultations with the radiologists.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/economia , Processamento de Imagem Assistida por Computador/normas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Intensificação de Imagem Radiográfica
2.
Afr Health Sci ; 22(2): 621-628, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36407382

RESUMO

Background: Projection diagnostic X-ray images are inherently affected by the masking effects of transmitted scatter. Spatially distributed transmitted scatter degrades image quality engendering need for effective scatter correction protocol. Objectives: To investigate origin of scatter components transmitted through anti-scatter grids to the detector of digital radiography system using Monte Carlo simulation. Methods: Over 107 photons were exposed through the reconstructed MC simulation phantom. Transmitted photons (primary and scatter) were scored as fluence, dose and deposited energy. Scatter components were investigated analytically over varying phantom thickness, tube kV and grid characteristics. Test disks were exposed as ROI embedded in phantom to evaluate the potential contrast improvement in image quality with the proposed technique. Results: Simulated and experimental results were comparable and in agreement with literature. SPR and SF mean values of 10.5, 0.314 and 7.96, 0.242 through grids of ratio 10:1 and 16:1 respectively was observed. Analysis of scatter components generation in object, grid's assembly, and fluorescent yields gave mean values of 0.815, 0.167 and 0.017, respectively. Image contrast was observed to increase with tube voltage and grid ratio. Conclusion: Achieving better image contrast, reduced patient dose and low scatter transmission while maintaining superior image quality, using grids with high grid ratio and selectivity is recommended.


Assuntos
Método de Monte Carlo , Humanos , Espalhamento de Radiação , Raios X , Imagens de Fantasmas
3.
J Appl Clin Med Phys ; 7(3): 80-94, 2006 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-17533338

RESUMO

Although the use of computed tomography (CT) in medical diagnosis delivers relatively higher radiation doses to patients than other radiological procedures, lack of optimized protocols could be an additional source of increased dose in developing countries. The aim of this study was to determine the magnitude of radiation doses received by selected radiosensitive organs of patients from CT examinations. The study was further carried out in order to assess the influence of existing CT scanning protocols on patient organ doses. In order to achieve these objectives, patient organ doses from five common CT examinations were obtained from eight hospitals in Tanzania. The patient organ doses were estimated using measurements of CTDI, exposure-related parameters and the NRPB conversion factors. Large variation of mean organ doses among hospitals was observed for similar CT examinations. These variations were largely originated from different CT scanning protocols employed in different hospitals and scanner type. The mean organ doses in this study for the lens of the eyes (for head), thyroid (for chest), breast (for chest), stomach (for abdomen), and ovary (for pelvis), were 63.9 mGy, 12.3 mGy, 26.1 mGy, 35.6 mGy, and 24.0 mGy, respectively. These values were mostly comparable and slightly higher than the values of organ doses reported from literature for the UK, Japan, Germany, Norway and the Netherlands. It was concluded that patient organ doses could substantially minimized through careful selection of scanning parameters based on clinical indications of study, patient size, and body region being examined. Additional dose reduction to superficial organs would require the use of shielding materials.


Assuntos
Fracionamento da Dose de Radiação , Neoplasias/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Radiometria , Reprodutibilidade dos Testes , Tanzânia
4.
J Med Phys ; 36(1): 22-8, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21430855

RESUMO

The aim of this study was to develop a homemade phantom for quantitative quality control in chest computed radiography (CR). The phantom was constructed from copper, aluminium, and polymenthylmethacrylate (PMMA) plates as well as Styrofoam materials. Depending on combinations, the literature suggests that these materials can simulate the attenuation and scattering characteristics of lung, heart, and mediastinum. The lung, heart, and mediastinum regions were simulated by 10 mm x 10 mm x 0.5 mm, 10 mm x 10 mm x 0.5 mm and 10 mm x 10 mm x 1 mm copper plates, respectively. A test object of 100 mm x 100 mm and 0.2 mm thick copper was positioned to each region for CNR measurements. The phantom was exposed to x-rays generated by different tube potentials that covered settings in clinical use: 110-120 kVp (HVL=4.26-4.66 mm Al) at a source image distance (SID) of 180 cm. An approach similar to the recommended method in digital mammography was applied to determine the CNR values of phantom images produced by a Kodak CR 850A system with post-processing turned off. Subjective contrast-detail studies were also carried out by using images of Leeds TOR CDR test object acquired under similar exposure conditions as during CNR measurements. For clinical kVp conditions relevant to chest radiography, the CNR was highest over 90-100 kVp range. The CNR data correlated with the results of contrast detail observations. The values of clinical tube potentials at which CNR is the highest are regarded to be optimal kVp settings. The simplicity in phantom construction can offer easy implementation of related quality control program.

5.
J Med Phys ; 36(3): 138-46, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21897559

RESUMO

The performances of three clinical computed radiography (CR) systems, (Agfa CR 75 (with CRMD 4.0 image plates), Kodak CR 850 (with Kodak GP plates) and Kodak CR 850A (with Kodak GP plates)) were evaluated using six tests recommended in American Association of Physicists in Medicine Report 93. The results indicated variable performances with majority being within acceptable limits. The variations were mainly attributed to differences in detector formulations, plate readers' characteristics, and aging effects. The differences of the mean low contrast scores between the imaging systems for three observers were statistically significant for Agfa and Kodak CR 850A (P=0.009) and for Kodak CR systems (P=0.006) probably because of the differences in ages. However, the differences were not statistically significant between Agfa and Kodak CR 850 (P=0.284) suggesting similar perceived image quality. The study demonstrates the need to implement quality control program regularly.