Diabetes Obes Metab ; 24(9): 1762-1769, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35546449

RESUMO

AIM: To investigate whether an increased bolus: basal insulin ratio (BBR) with liver-targeted bolus insulin (BoI) would increase BoI use and decrease hypoglycaemic events (HEv). PATIENT POPULATION AND METHODS: We enrolled 52 persons (HbA1c 6.9% ± 0.12%, mean ± SEM) with type 1 diabetes using multiple daily injections. Hepatic-directed vesicle (HDV) was used to deliver 1% of peripheral injected BoI to the liver. A 90-day run-in period was used to introduce subjects to unblinded continuous glucose monitoring and optimize standard basal insulin (BaI) (degludec) and BoI (lispro) dosing. At 90 days, BoI was changed to HDV-insulin lispro and subjects were randomized to an immediate 10% or 40% decrease in BaI dose. RESULTS: At 90 days postrandomization, total insulin dosing was increased by ~7% in both cohorts. The -10% and -40% BaI cohorts were on 7.7% and 13% greater BoI with 6.9% and 30% (P = .02) increases in BBR, respectively. Compared with baseline at randomization, nocturnal level 2 HEv were reduced by 21% and 43%, with 54% and 59% reductions in patient-reported HEv in the -10% and -40% BaI cohorts, respectively. CONCLUSIONS: Our study shows that liver-targeted BoI safely decreases HEv and symptoms without compromising glucose control. We further show that with initiation of liver-targeted BoI, the BBR can be safely increased by significantly lowering BaI dosing, leading to greater BoI usage.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Hipoglicemia , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemia/epidemiologia , Hipoglicemia/prevenção & controle , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos , Insulina Glargina , Insulina Lispro/uso terapêutico , Insulina de Ação Prolongada , Insulina Regular Humana , Fígado/química
2.
Diabetes Obes Metab ; 24(6): 1143-1149, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35257468

RESUMO

AIM: To assess the feasibility of a prototype insulin infusion set (IIS) for extended wear in adults with type 1 diabetes. MATERIALS AND METHODS: The prototype Capillary Biomedical investigational extended-wear IIS (CBX IIS) incorporates a soft, flexible, reinforced kink-resistant angled nylon-derivative cannula with one distal and three proximal ports to optimize insulin delivery. Twenty adult participants with type 1 diabetes established on insulin pump therapy used the CBX IIS for two 7-day test periods while wearing a Dexcom G5 continuous glucose monitor. RESULTS: Participants were able to wear the CBX IIS for an average of 6.6 ± 1.4 days. Eighty-eight percent (36 of 41) of sets were worn for 7 days. No serious adverse events were reported. Five infusion sets failed prematurely because of: unresolvable hyperglycaemia (three); hyperglycaemia with elevated ketones (one); or infection (one). Median time in range (3.9-10.0 mmol/L) was 62% (54-76). Average glucose levels per day of infusion set wear showed a statistically significant increase over time (p < .001). CONCLUSIONS: Our preliminary observations confirm the tolerability of the prototype CBX IIS for extended wear, albeit with a deterioration in glucose control after the third day.


Assuntos
Diabetes Mellitus Tipo 1 , Hiperglicemia , Adulto , Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Estudos de Viabilidade , Humanos , Hiperglicemia/prevenção & controle , Hipoglicemiantes/uso terapêutico , Insulina/efeitos adversos , Sistemas de Infusão de Insulina/efeitos adversos
3.
Diabetes Metab Res Rev ; 33(5)2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28054743

RESUMO

Hypoglycemia complicating diabetes therapy is well recognized to be an ever-present threat to patients, their families, providers, payers, and regulators. Despite this being widely acknowledged, the regulatory stance on hypoglycemia as an endpoint in clinical trials to support new product registration has not evolved in any meaningful way since the publication of a position paper by an American Diabetes Association (ADA) Workgroup in 2005. As the impact of hypoglycemia on persons affected by diabetes is of major importance when assessing new treatments, the historical position of regulatory agencies on hypoglycemia is reviewed with respect to product approvals. The purpose of this article is to present proposals for facilitating development of therapies that reduce hypoglycemia risk through (1) development of composite measures of benefit for regulatory endpoints and (2) facilitation of the fulfillment of an unmet clinical need for reducing hypoglycemia. In view of greater comprehension of the effects of hypoglycemia, coupled with improved methodology to assess its frequency, the authors recommend: (1) a numerical cut point of <54 mg/dl (<3.0 mmol/L) as a clinically relevant level with which to define meaningful hypoglycemia for trials of diabetes therapies; (2) utilization in clinical trials of mature glucose monitoring technologies for purposes of regulatory evaluation and clinical decision-making; and (3) development of primary efficacy endpoint composites that include hypoglycemia rates and glycemic control.


Assuntos
Diabetes Mellitus Tipo 2/complicações , Hipoglicemia/induzido quimicamente , Hipoglicemiantes/efeitos adversos , Glicemia/metabolismo , Humanos , Hipoglicemia/metabolismo
4.
J Diabetes Sci Technol ; 18(1): 215-239, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37811866

RESUMO

The Fifth Artificial Pancreas Workshop: Enabling Fully Automation, Access, and Adoption was held at the National Institutes of Health (NIH) Campus in Bethesda, Maryland on May 1 to 2, 2023. The organizing Committee included representatives of NIH, the US Food and Drug Administration (FDA), Diabetes Technology Society, Juvenile Diabetes Research Foundation (JDRF), and the Leona M. and Harry B. Helmsley Charitable Trust. In previous years, the NIH Division of Diabetes, Endocrinology, and Metabolic Diseases along with other diabetes organizations had organized periodic workshops, and it had been seven years since the NIH hosted the Fourth Artificial Pancreas in July 2016. Since then, significant improvements in insulin delivery have occurred. Several automated insulin delivery (AID) systems are now commercially available. The workshop featured sessions on: (1) Lessons Learned from Recent Advanced Clinical Trials and Real-World Data Analysis, (2) Interoperability, Data Management, Integration of Systems, and Cybersecurity, Challenges and Regulatory Considerations, (3) Adaptation of Systems Through the Lifespan and Special Populations: Are Specific Algorithms Needed, (4) Development of Adaptive Algorithms for Insulin Only and for Multihormonal Systems or Combination with Adjuvant Therapies and Drugs: Clinical Expected Outcomes and Public Health Impact, (5) Novel Artificial Intelligence Strategies to Develop Smarter, More Automated, Personalized Diabetes Management Systems, (6) Novel Sensing Strategies, Hormone Formulations and Delivery to Optimize Close-loop Systems, (7) Special Topic: Clinical and Real-world Viability of IP-IP Systems. "Fully automated closed-loop insulin delivery using the IP route," (8) Round-table Panel: Closed-loop performance: What to Expect and What are the Best Metrics to Assess it, and (9) Round-table Discussion: What is Needed for More Adaptable, Accessible, and Usable Future Generation of Systems? How to Promote Equitable Innovation? This article summarizes the discussions of the Workshop.


Assuntos
Diabetes Mellitus Tipo 1 , Pâncreas Artificial , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina/uso terapêutico , Glicemia , Inteligência Artificial , Sistemas de Infusão de Insulina , Insulina Regular Humana/uso terapêutico , Automação , Hipoglicemiantes/uso terapêutico
5.
J Diabetes Sci Technol ; : 19322968241235205, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38528741

RESUMO

Diabetes Technology Society hosted its annual Diabetes Technology Meeting from November 1 to November 4, 2023. Meeting topics included digital health; metrics of glycemia; the integration of glucose and insulin data into the electronic health record; technologies for insulin pumps, blood glucose monitors, and continuous glucose monitors; diabetes drugs and analytes; skin physiology; regulation of diabetes devices and drugs; and data science, artificial intelligence, and machine learning. A live demonstration of a personalized carbohydrate dispenser for people with diabetes was presented.

6.
Diabetes Technol Ther ; 25(2): 143-147, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36342853

RESUMO

Insulin exposure varies over 3 days of insulin infusion set (IIS) wear making day-to-day insulin dosing challenging for people with diabetes (PWD). Here we report insulin pharmacodynamic (PD) and pharmacokinetic (PK) data extending these observations to 7 days of IIS wear. PWD (A1C ≤8.5%, C-peptide <0.6 nmol/L, ≥6 months pump use) were enrolled in a crossover euglycemic clamp pilot study comparing conventional Teflon angled IISs with an investigational extended-wear IIS. PK/PD data from six participants were obtained for 5 h postbolus. Although PD data were unstable, PK profiles (pooled data from both groups) of insulin lispro (0.15 U/kg bolus) showed statistically significant progressive decreases from days 0 to 7 for tmax (P < 0.001), Cmax (P < 0.05), and mean residence time (P < 0.0001). Area under the insulin concentration curve (AUC0-300) declined by ∼24% from days 0 to 7 (P < 0.05). These results confirm/extend previous observations showing progressive acceleration of insulin exposure over IIS wear time. This may have implications for PWD and designers of closed-loop algorithms, although larger studies are necessary to confirm this. The study was registered in clinicaltrials.gov (NCT04398030).


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus , Humanos , Insulina , Hipoglicemiantes , Projetos Piloto , Insulina Lispro , Insulina Regular Humana/uso terapêutico , Técnica Clamp de Glucose , Estudos Cross-Over , Diabetes Mellitus Tipo 1/tratamento farmacológico , Sistemas de Infusão de Insulina , Glicemia
7.
Diabetes Technol Ther ; 11(6): 345-52, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19459762

RESUMO

BACKGROUND: This phase 1 study investigated the pharmacokinetics (PK) and glucodynamics of insulin lispro (Humalog; Eli Lilly and Co., Indianapolis, IN) or regular human insulin (Humulin R; Eli Lilly and Co.) administered with or without (+/-) recombinant human hyaluronidase (rHuPH20). METHODS: Healthy male volunteers (n = 26), 18-55 years old with body mass index 18-28 kg/m(2), weight >70 kg, and normal fasting glucose, were randomized to a crossover sequence of two subcutaneous injections, each followed by a 6-h euglycemic clamp targeting glucose 90-110 mg/dL: Cohort 1 received 20 U of Humalog +/- 300 U of rHuPH20 (11.3 microg/mL), whereas Cohort 2 received 20 U of Humulin R +/- 240 U of rHuPH20 (10 microg/mL). Pharmacokinetic parameters included peak serum insulin concentration (C(max)), time to C(max) (t(max)), and area under the curve (AUC) of serum concentration versus time. Glucodynamic parameters included time to maximal glucose infusion rate (tGIR(max)) and area under the GIR-versus-time curve (G). RESULTS: For Humalog and Humulin R, respectively, rHuPH20 co-administration reduced t(max) by 51% (P = 0.0006) and 58% (P = 0.0002), increased C(max) by 90% (P = 0.0003) and 142% (P < 0.0001), increased early exposure (AUC(0-2h)) by 85% (P < 0.0001) and 211% (P < 0.0001), and reduced late exposure (AUC(4-6h)) by 41% (P < 0.0001) and 48% (P < 0.0001). Similarly, rHuPH20 reduced tGIR(max) by 41% (P = 0.006) and 35% (P = 0.01), increased early metabolism (G(0-2h)) by 52% (P = 0.001) and 127% (P < 0.0001), and reduced late metabolism (G(4-6h)) by 29% (P = 0.002) and 26% (P = 0.03) for Humalog and Humulin R, respectively. Injections were well tolerated. CONCLUSIONS: Co-administration of rHuPH20 accelerated the PK and glucodynamics of both insulin formulations. Additional studies are necessary to evaluate the clinical relevance of these findings in patients with diabetes.


Assuntos
Glicemia/metabolismo , Hialuronoglucosaminidase/farmacologia , Insulina/análogos & derivados , Insulina/sangue , Adolescente , Adulto , Glicemia/efeitos dos fármacos , Estudos Cross-Over , Humanos , Hipoglicemiantes/farmacocinética , Hipoglicemiantes/farmacologia , Insulina/farmacocinética , Insulina/farmacologia , Insulina Lispro , Masculino , Pessoa de Meia-Idade , Proteínas Recombinantes/farmacologia , Valores de Referência , Adulto Jovem
8.
Diabetes Care ; 42(11): 2154-2157, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31551249

RESUMO

OBJECTIVE: Hepatic-directed vesicle insulin (HDV) uses a hepatocyte-targeting moiety passively attaching free insulin, improving subcutaneous insulin's hepatic biodistribution. We assessed HDV-insulin lispro (HDV-L) versus insulin lispro (LIS) in type 1 diabetes (T1D). RESEARCH DESIGN AND METHODS: Insulin Liver Effect (ISLE-1) was a 26-week, phase 2b, multicenter, randomized, double-blind, noninferiority trial. RESULTS: Among 176 randomized participants (HDV-L n = 118, LIS n = 58), the difference in change from baseline A1C was 0.09% (95% CI -0.18% to 0.35%), confirming noninferiority (prespecified margin ≤0.4%). Overall, there were no statistically significant differences between treatments for hypoglycemia or insulin dosing. However, baseline A1C modified the treatment group effect (interaction P < 0.001) on clinically apparent hypoglycemia designated by treatment-blinded investigators as severe. Thus, at higher baseline A1C, there was less hypoglycemia and lower insulin dosing with similar A1C outcomes during HDV-L versus LIS, whereas greater risk of hypoglycemia despite similar A1C outcomes and insulin doses was observed with lower baseline A1C. Among poorly controlled participants (A1C ≥8.5%), incidence rates of severe hypoglycemia in the HDV-L and LIS arms were 69 and 97 events/100 person-years, respectively (P = 0.03), whereas with A1C <8.5%, respective rates were 191 and 21 events/100 person-years (P = 0.001). Similar A1C-dependent trends in hypoglycemia were seen with continuous glucose monitoring. Among poorly controlled participants, bolus insulin doses at end point were ∼25% lower with HDV-L (P = 0.02), despite similar A1C outcomes; in better-controlled participants, insulin doses and A1Cs were stable over time in both subgroups. No safety signals were identified. CONCLUSIONS: Hepatic biodistribution of HDV-L appears to potentiate insulin effect in T1D, with divergent clinical outcomes in hypoglycemia dependent on baseline A1C.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/efeitos dos fármacos , Hipoglicemiantes/farmacocinética , Insulina Lispro/farmacocinética , Insulina/farmacocinética , Adulto , Glicemia/efeitos dos fármacos , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/complicações , Relação Dose-Resposta a Droga , Método Duplo-Cego , Feminino , Humanos , Hipoglicemia/tratamento farmacológico , Hipoglicemia/etiologia , Fígado/metabolismo , Masculino , Refeições , Pessoa de Meia-Idade , Período Pós-Prandial/efeitos dos fármacos , Distribuição Tecidual , Resultado do Tratamento
9.
Br J Clin Pharmacol ; 65(4): 480-7, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17922880

RESUMO

WHAT IS ALREADY KNOWN ABOUT THIS SUBJECT: * Only one other study (Becker et al.) has reported on the influence of smoking cessation and smoking resumption on inhaled insulin pharmacokinetics and glucodynamics, concluding that the rapid changes associated with smoking resumption carry the risk for hypoglycaemia and thus should not be used by active smokers. WHAT THIS STUDY ADDS: * This is the first euglycaemic clamp study on the impact of smoking cessation, acute smoking re-exposure and nicotine replacement on AIR((R)) inhaled insulin pharmacokinetics and glucodynamics. * We demonstrate clinically and statistically significant shifts in glucodynamic response to acute re-exposure to a single cigarette, leading us to conclude that active smokers should be advised against inhaled insulin therapy until smoking abstinence is stable. * Additionally, these results are also the first to demonstrate an apparent independent effect of nicotine replacement therapy on insulin exposure and glucodynamic response. AIMS: To explore the effects of smoking cessation and acute smoking re-exposure on the pharmacokinetic (PK) and glucodynamic (GD) profiles of AIR inhaled insulin (AIR Insulin) with or without nicotine replacement therapy (NRT). METHODS: Nondiabetic smokers (n = 24) with normal pulmonary function completed a two-phase (four-period), open-label, randomized euglycaemic clamp study. During the initial study phase, subjects underwent glucose clamps following AIR Insulin dosing, shortly after smoking, 8-12 h after smoking, or following subcutaneous insulin lispro shortly after smoking. AIR Insulin PK and GD were again assessed during and after a 4-week smoking-cessation period with or without NRT. In the last study period, subjects smoked one cigarette shortly before final AIR Insulin dosing and glucose clamp, to study the effect of acute smoking re-exposure on inhaled insulin PK and GD. RESULTS: Compared with the preceding active smoking phase, the administration of AIR Insulin in nondiabetic subjects undergoing a 4-week period of smoking abstinence resulted in a decrease in PK and GD of approximately 25% (P = 0.008 for both), an effect which was greater in subjects using NRT. Following rechallenge with a single cigarette (without NRT), GD response to AIR Insulin increased significantly (P = 0.006) towards precessation levels, relative to smoking abstinence. In subjects using NRT, however, the increase in GD was less pronounced. CONCLUSION: Smoking, smoking cessation and acute re-exposure with a single cigarette are associated with clinically significant alterations in AIR Insulin pharmacokinetics and glucodynamics. AIR Insulin should not be used by smokers or those at risk for recidivism.


Assuntos
Glicemia/metabolismo , Hipoglicemiantes/farmacocinética , Insulina/farmacocinética , Fumar/sangue , Absorção/fisiologia , Administração por Inalação , Adulto , Métodos Epidemiológicos , Feminino , Técnica Clamp de Glucose/métodos , Humanos , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Masculino , Pessoa de Meia-Idade , Abandono do Hábito de Fumar , Resultado do Tratamento
10.
J Diabetes Sci Technol ; 12(1): 152-154, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29291651

RESUMO

Recently approved in Europe, Canada, and the United States, fast-acting insulin aspart (FIASP®) is a new rapid acting insulin. Approved for subcutaneous or IV injection use, there is little data available regarding the clinical utility of FIASP in insulin pumps. The article by Zijlstra and colleagues in this issue begins to close this gap by testing pump compatibility of FIASP in the clinic. Reporting on a small (37 subjects) and short (6 weeks) study looking at aspects of infusion set propensity for clogging and malfunction, no cases of infusion set plugging in either FIASP (25 subjects) or insulin aspart (12 subjects) were seen. Unexplained hyperglycemia and premature infusion set changes were more common with FIASP than with insulin aspart. This study demonstrated sufficient safety and efficacy of FIASP in the pump setting to pave the way for longer, larger and more definitive clinical trials.


Assuntos
Diabetes Mellitus Tipo 1 , Glicemia , Canadá , Europa (Continente) , Humanos , Hipoglicemiantes , Insulina , Insulina Aspart
11.
BioDrugs ; 32(1): 83-89, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29442293

RESUMO

BACKGROUND: Recombinant human PH20 (rHuPH20) is used to depolymerize hyaluronan in the subcutaneous space, increasing the dispersion and absorption of co-administered drugs. While ~ 5 to 10% of rHuPH20 treatment-naïve healthy volunteers have demonstrated rHuPH20-reactive antibodies, associations with age, sex, fertility, and immune disorders remain unknown. OBJECTIVES: Using demographically diverse healthy volunteers, we assessed the prevalence of rHuPH20-reactive antibodies in the general population and potential associations with fertility and autoimmunity diseases. METHODS: In total, 896 subjects aged ≥ 12 years (767 adults; 129 children) without prior exposure to rHuPH20 were enrolled. A demographic and limited medical history review was performed, and K3-EDTA-anticoagulated plasma was analyzed for rHuPH20-reactive antibodies using a bridging immunoassay. RESULTS: Adult and pediatric positivity rates for rHuPH20-reactive antibodies were 5.2% (40/767) and 1.6% (2/129), respectively. Titers ranged from 5 to 2560 (median 30). In five antibody-positive subjects from whom repeated samples were available, antibody titers remained unchanged or decreased fourfold over periods up to 590 days. The prevalence of rHuPH20-reactive antibodies significantly increased with age (p = 0.0006) and was significantly higher in males than in females (p = 0.0010). Men who had fathered children had a significantly increased prevalence of rHuPH20-reactive antibodies than men who had not (p = 0.0036), whereas the rate of childbearing was not significantly different between rHuPH20 antibody-positive and -negative women. The prevalence between racial/ethnic groups was not significantly different, nor was the presence/absence of an autoimmune disorder. CONCLUSIONS: Approximately 1/20 of the adult population had rHuPH20-reactive antibodies. The reason remains unknown; however, no evidence for a negative effect on fertility or association with autoimmune disease was demonstrated.


Assuntos
Anticorpos/sangue , Moléculas de Adesão Celular/imunologia , Hialuronoglucosaminidase/imunologia , Proteínas Recombinantes/imunologia , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Criança , Pai , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Fatores Sexuais , Adulto Jovem
12.
Diabetes Technol Ther ; 9 Suppl 1: S41-7, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17563303

RESUMO

The diabetes epidemic and lack of adequate glycemic control in patients with diabetes emphasize the need for alternative diabetes treatment strategies. Although many new compounds have been developed, insulin remains the most potent agent for controlling glycemia. Inhaled insulin systems have been developed to alleviate the fear of insulin injections and to improve the convenience of insulin administration. The AIR Inhaled Insulin System being developed by Eli Lilly (Indianapolis, IN) and Alkermes (Cambridge, MA) uses AIR particle technology to deliver dry powder insulin to the deep lung. Pharmacokinetic and glucodynamic data in Phase 1 clinical trials have demonstrated that AIR Insulin is rapidly absorbed with prolonged insulin exposure and action compared to insulin lispro. AIR Insulin has also been shown to have dose equivalence and dose reproducibility across a range of doses, and it has been shown that three inhalations of the 2 U-equivalent dose can be interchanged with one 6 U-equivalent dose. A Phase 2 study demonstrated preference for AIR Insulin over subcutaneous injectable insulins, and a recent study reported that the system is easy to teach and use. Several Phase 3 studies are currently underway to further investigate the safety and efficacy and to evaluate the system's intention to meet provider and patient expectations.


Assuntos
Administração por Inalação , Aerossóis , Insulina/farmacocinética , Insulina/uso terapêutico , Glicemia/efeitos dos fármacos , Glicemia/metabolismo , Desenho de Equipamento , Humanos , Insulina/administração & dosagem , Insulina/análogos & derivados , Insulina Lispro , Nebulizadores e Vaporizadores
13.
Diabetes Technol Ther ; 9(1): 80-8, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17316102

RESUMO

BACKGROUND: The Lilly/Alkermes human insulin inhalation powder (HIIP) delivery system [AIR (a registered trademark of Alkermes, Inc., Cambridge, MA) Inhaled Insulin System] was designed to be easy to use. Training methods were compared in insulin-naive patients with type 2 diabetes. METHODS: Patients (n = 102) were randomized to standard or intensive training. With standard training, patients learned how to use the HIIP delivery system by reading directions for use (DFU) and trying on their own. Intensive training included orientation to the HIIP delivery system with individual coaching and inspiratory flow rate training. Both groups received preprandial HIIP + metformin with or without a thiazolidinedione for 4 weeks. Overall 2-h postprandial blood glucose (PPBG) excursion was the primary measure. Noninferiority was defined as the upper limit of the two-sided 95% confidence interval of the mean difference between groups being 1.2 < or = mmol/L. RESULTS: Overall 2-h PPBG excursions (least squares mean +/- SE) at endpoint were -0.11 +/- 0.38 (standard training) and 0.23 +/- 0.36 (intensive training) mmol/L. The mean difference (standard minus intensive training) and two-sided 95% confidence interval were -0.35 (-1.02, 0.33) mmol/L. No statistically or clinically significant differences were observed between training methods in premeal, postmeal, or bedtime blood glucose values, HIIP doses at endpoint, or blood glucose values after a test meal. No discontinuations occurred because of difficulty of use or dislike of the HIIP system. DFU compliance was >90% in both training groups. There were no significant differences between training methods in safety measures. CONCLUSIONS: The HIIP delivery system is easy to use, and most patients can learn to use it by reading the DFU without assistance from health care professionals.


Assuntos
Diabetes Mellitus Tipo 2/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Educação de Pacientes como Assunto/métodos , Administração por Inalação , Idoso , Peso Corporal , Diabetes Mellitus Tipo 2/sangue , Feminino , Humanos , Hipoglicemia/etiologia , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/farmacocinética , Insulina/efeitos adversos , Insulina/farmacocinética , Masculino , Pessoa de Meia-Idade , Radiografia Torácica , Distribuição Aleatória , Testes de Função Respiratória , Método Simples-Cego , Resultado do Tratamento
14.
Vasc Health Risk Manag ; 3(6): 947-58, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18200813

RESUMO

Diabetes mellitus is a significant worldwide health problem, with the incidence of type 2 diabetes increasing at alarming rates. Insulin resistance and dysregulated blood glucose control are established risk factors for microvascular complications and cardiovascular disease. Despite the recognition of diabetes as a major health issue and the availability of a growing number of medications designed to counteract its detrimental effects, real and perceived barriers remain that prevent patients from achieving optimal blood glucose control. The development and utilization of inhaled insulin as a novel insulin delivery system may positively influence patient treatment adherence and optimal glycemic control, potentially leading to a reduction in cardiovascular complications in patients with diabetes.


Assuntos
Diabetes Mellitus/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Administração por Inalação , Doenças Cardiovasculares/fisiopatologia , Contraindicações , Diabetes Mellitus/fisiopatologia , Sistemas de Liberação de Medicamentos , Hemoglobinas Glicadas/análise , Humanos , Educação de Pacientes como Assunto , Satisfação do Paciente , Período Pós-Prandial
15.
J Diabetes Sci Technol ; 11(1): 157-159, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-28264172

RESUMO

Considerable progress in treatment of diabetes has been made in the nearly 100 years following the discovery of insulin, and advances in insulin therapy have improved convenience, quality of life, overall glycemic control (A1C), and risk of hypoglycemia. An unmet need remains for a mealtime insulin that can faithfully reproduce the metabolic profile that ensues following meal ingestion in healthy persons. A number of "ultra-fast" insulin programs have been initiated, and Afrezza® (insulin human; Inhalation Powder, MannKind Corporation, Danbury, CT) stands as the first such product to be approved by the US FDA. Afrezza is unique as an "ultra-ultra" fast insulin, faster than any other entrant except IV insulin. The benefits and limitations of the Afrezza profile are discussed in this analysis.


Assuntos
Diabetes Mellitus/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Administração por Inalação , Humanos
17.
Diabetes Care ; 28(10): 2400-5, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16186270

RESUMO

OBJECTIVE: To determine the pharmacokinetic (PK) and glucodynamic (GD) dose response of human insulin inhalation powder (HIIP) delivered via AIR particle technology and dose equivalence to subcutaneous (SC) insulin lispro. RESEARCH DESIGN AND METHODS: Twenty healthy, nonsmoking, male or female subjects (aged 29.6 +/- 6.9 years, BMI 23.2 +/- 2.3 kg/m2, means +/- SD) with normal forced vital capacity and forced expiratory volume were enrolled in an open-label, randomized, seven-period, euglycemic glucose clamp, cross-over trial. Each subject received up to four single doses of HIIP (2.6, 3.6, 5.2, or 7.8 mg) and three doses of SC lispro (6, 12, or 18 units) from 5 to 18 days apart. RESULTS: HIIP demonstrated a similar rapid onset but an extended time exposure and a prolonged duration of effect (late t(50%) 412 vs. 236 min, P < 0.001) compared with SC lispro. The HIIP versus SC lispro doses of 2.6 mg vs. 6 units, 5.2 mg vs. 12 units, and 7.8 mg vs. 18 units achieved similar PK area under the serum immunoreactive insulin (IRI) concentration-versus-time curve from time zero until the serum IRI concentrations returned to the predose baseline value [AUC(0-t')] and GD (G(tot)) responses. The median insulin (t(max)) was not different between HIIP and SC lispro (45 min for both), although the median time of return to baseline for PK was apparently longer for HIIP compared with SC lispro (480 vs. 360 min). Relative bioavailability and relative biopotency of HIIP were consistent across doses (8 and 9%). CONCLUSIONS: While the time-action profile was longer for HIIP than for SC lispro, both treatments showed rapid initial absorption and similar overall PK exposure and GD effect. HIIP was as well tolerated as SC lispro, thereby offering a promising alternative to injectable insulin therapy.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Insulina/análogos & derivados , Insulina/administração & dosagem , Administração por Inalação , Adulto , Estudos Cross-Over , Feminino , Técnica Clamp de Glucose , Humanos , Hipoglicemiantes/farmacocinética , Injeções Subcutâneas , Insulina/farmacocinética , Insulina Lispro , Masculino , Inaladores Dosimetrados , Pós , Resultado do Tratamento
18.
AAPS J ; 17(5): 1144-56, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25967925

RESUMO

Recombinant human PH20 hyaluronidase (rHuPH20) is used to facilitate dispersion of subcutaneously delivered fluids and drugs. This report summarizes rHuPH20 immunogenicity findings from clinical trials where rHuPH20 was co-administered with SC human immunoglobulin, trastuzumab, rituximab, or insulin. Plasma samples were obtained from evaluable subjects participating in ten different clinical trials as well as from healthy plasma donors. A bridging immunoassay and a modified hyaluronidase activity assay were used to determine rHuPH20-reactive antibody titers and neutralizing antibodies, respectively. rHuPH20-binding antibody populations from selected subjects with positive titers were affinity-purified and subjected to further characterization such as cross-reactivity with endogenous PH20. Among individual trials, the prevalence of pre-existing rHuPH20-reactive antibodies varied between 3 and 12%, excepting the primary immunodeficiency (PID) studies. Incidence of treatment-induced rHuPH20 antibodies was 2 to 18%, with the highest titers (81,920) observed in PID. No neutralizing antibodies were observed. Within most trials, the kinetics of antibody responses were comparable between pre-existing and treatment-induced antibody responses, although responses classified as persistent were more common in subjects with pre-existing titers. There was no association between antibody positivity and either local or systemic adverse events. Pre-existing and treatment-induced antibody populations were of similar immunoglobulin isotypes and cross-reacted to endogenous PH20 to similar extents. No cross-reactivity to PH20 paralogs was detected. rHuPH20 induces only modest immunogenicity which has no association with adverse events. In addition, antibodies purified from baseline-positive individuals are qualitatively similar to those purified from individuals developing rHuPH20-reactive antibodies following exposure to the enzyme.


Assuntos
Anticorpos Neutralizantes/sangue , Anticorpos/sangue , Hialuronoglucosaminidase/administração & dosagem , Proteínas Recombinantes/administração & dosagem , Ensaios Clínicos como Assunto , Humanos , Hialuronoglucosaminidase/imunologia , Injeções Subcutâneas , Insulina/administração & dosagem , Proteínas Recombinantes/imunologia , Rituximab/administração & dosagem , Trastuzumab/administração & dosagem
19.
Diabetes Care ; 36(2): 273-5, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23043164

RESUMO

OBJECTIVE: To compare the pharmacokinetics and glucodynamics of three rapid-acting insulin analogs (aspart, glulisine, and lispro) injected subcutaneously with or without recombinant human hyaluronidase (rHuPH20). RESEARCH DESIGN AND METHODS: This double-blind six-way crossover euglycemic glucose clamp study was conducted in 14 healthy volunteers. Each analog was injected subcutaneously (0.15 units/kg) with or without rHuPH20. RESULTS: The commercial formulations had comparable insulin time-exposure and time-action profiles as follows: 50% exposure at 123-131 min and 50% total glucose infused at 183-186 min. With rHuPH20, the analogs had faster yet still comparable profiles: 50% exposure at 71-79 min and 50% glucose infused at 127-140 min. The accelerated absorption with rHuPH20 led to twice the exposure in the first hour and half the exposure beyond 2 h, which resulted in 13- to 25-min faster onset and 40- to 49-min shorter mean duration of insulin action. CONCLUSIONS: Coinjection of rHuPH20 with rapid-acting analogs accelerated insulin exposure, producing an ultra-rapid time-action profile with a faster onset and shorter duration of insulin action.


Assuntos
Hialuronoglucosaminidase/farmacocinética , Hipoglicemiantes/farmacocinética , Insulina de Ação Curta/farmacocinética , Insulina/análogos & derivados , Insulina/farmacocinética , Adulto , Estudos Cross-Over , Método Duplo-Cego , Interações Medicamentosas , Feminino , Humanos , Hialuronoglucosaminidase/administração & dosagem , Hipoglicemiantes/administração & dosagem , Injeções Subcutâneas , Insulina/administração & dosagem , Insulina de Ação Curta/administração & dosagem , Masculino
20.
J Diabetes Sci Technol ; 6(4): 728-42, 2012 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-22920797

RESUMO

Optimal coverage of prandial insulin requirements remains an elusive goal. The invention of rapid-acting insulin analogs (RAIAs) was a big step forward in reducing postprandial glycemic excursions in patients with diabetes in comparison with using regular human insulin; however, even with these, the physiological situation cannot be adequately mimicked. Developing ultrafast-acting insulins (UFIs)-showing an even more rapid onset of action and a shorter duration of action after subcutaneous (SC) administration-is another step forward in achieving this goal. The need for UFIs has been gradually recognized over the years, and subsequently, a number of different approaches to cover this need are in clinical development. A rapid increase in circulating insulin levels can be achieved by different measures: modification of the primary structure of insulin molecule (as we know from RAIAs), addition of excipients that enhance the appearance in the monomeric state post-injection, or addition of enzymes that enable more free spreading of the insulin molecules in the SC tissue. Other measures to increase the insulin absorption rate increase the local blood flow nearby the insulin depot in the SC tissue, injecting the insulin intradermally or applying via another route, e.g., the lung. The development of these approaches is in different stages, from quite early stages to nearing market authorization. In time, daily practice will show if the introduction of UFIs will fulfill their clinical promise. In this review, the basic idea for UFIs will be presented and the different approaches will be briefly characterized.


Assuntos
Diabetes Mellitus/tratamento farmacológico , Sistemas de Liberação de Medicamentos , Insulina de Ação Curta/administração & dosagem , Absorção , Química Farmacêutica/métodos , Formas de Dosagem , Sistemas de Liberação de Medicamentos/instrumentação , Sistemas de Liberação de Medicamentos/métodos , Sistemas de Liberação de Medicamentos/normas , Humanos , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/farmacocinética , Infusões Subcutâneas , Sistemas de Infusão de Insulina/normas , Insulina de Ação Curta/farmacocinética , Padrão de Cuidado , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA