Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
Eur Radiol ; 2023 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-37979008

RESUMO

INTRODUCTION: This study investigated the use of dual-energy spectral detector computed tomography (CT) and virtual monoenergetic imaging (VMI) reconstructions in pre-interventional transcatheter aortic valve replacement (TAVR) planning. We aimed to determine the minimum required contrast medium (CM) amount to maintain diagnostic CT imaging quality for TAVR planning. METHODS: In this prospective clinical trial, TAVR candidates received a standardized dual-layer spectral detector CT protocol. The CM amount (Iohexol 350 mg iodine/mL, standardized flow rate 3 mL/s) was reduced systematically after 15 patients by 10 mL, starting at 60 mL (institutional standard). We evaluated standard, and 40- and 60-keV VMI reconstructions. For image quality, we measured signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and diameters in multiple vessel sections (i.e., aortic annulus: diameter, perimeter, area; aorta/arteries: minimal diameter). Mixed regression models (MRM), including interaction terms and clinical characteristics, were used for comparison. RESULTS: Sixty consecutive patients (mean age, 79.4 ± 7.5 years; 28 females, 46.7%) were included. In pre-TAVR CT, the CM reduction to 40 mL is possible without affecting the image quality (MRM: SNR: -1.1, p = 0.726; CNR: 0.0, p = 0.999). VMI 40-keV reconstructions showed better results than standard reconstructions with significantly higher SNR (+ 6.04, p < 0.001). Reduction to 30 mL CM resulted in a significant loss of quality (MRM: SNR: -12.9, p < 0.001; CNR: -13.9, p < 0.001), regardless of the reconstruction. Across the reconstructions, we observed no differences in the metric evaluation (p > 0.914). CONCLUSION: Among TAVR candidates undergoing pre-interventional CT at a dual-layer spectral detector system, applying 40 mL CM is sufficient to maintain diagnostic image quality. VMI 40-keV reconstructions improve the vessel attenuation and are recommended for evaluation. CLINICAL RELEVANCE STATEMENT: Contrast medium reduction to 40 mL in pre-interventional transcatheter aortic valve replacement CT using dual-energy CT maintains image quality, while 40-keV virtual monoenergetic imaging reconstructions enhance vessel attenuation. These results offer valuable recommendations for interventional transcatheter aortic valve replacement evaluation and potentially improve nephroprotection in patients with compromised renal function. KEY POINTS: • Patients undergoing transcatheter aortic valve replacement (TAVR), requiring pre-interventional CT, are often multimorbid with impaired renal function. • Using a spectral detector dual-layer CT, contrast medium reduction to 40 mL is feasible, maintaining diagnostic image quality. • The additional application of virtual monoenergetic image reconstructions with 40 keV improves vessel attenuation significantly in clinical practice.

2.
J Cardiovasc Magn Reson ; 22(1): 89, 2020 12 17.
Artigo em Inglês | MEDLINE | ID: mdl-33327958

RESUMO

BACKGROUND: Late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) represents the gold standard for assessment of myocardial viability. The purpose of this study was to investigate the clinical potential of Compressed SENSE (factor 5) accelerated free-breathing three-dimensional (3D) whole heart LGE with high isotropic spatial resolution (1.4 mm3 acquired voxel size) compared to standard breath-hold LGE imaging. METHODS: This was a retrospective, single-center study of 70 consecutive patients (45.8 ± 18.1 years, 27 females; February-November 2019), who were referred for assessment of left ventricular myocardial viability and received free-breathing and breath-hold LGE sequences at 1.5 T in clinical routine. Two radiologists independently evaluated global and segmental LGE in terms of localization and transmural extent. Readers scored scans regarding image quality (IQ), artifacts, and diagnostic confidence (DC) using 5-point scales (1 non-diagnostic-5 excellent/none). Effects of heart rate and body mass index (BMI) on IQ, artifacts, and DC were evaluated with ordinal logistic regression analysis. RESULTS: Global LGE (n = 33) was identical for both techniques. Using free-breathing LGE (average scan time: 04:33 ± 01:17 min), readers detected more hyperenhanced lesions (28.2% vs. 23.5%, P < .05) compared to breath-hold LGE (05:15 ± 01:23 min, P = .0104), pronounced at subepicardial localization and for 1-50% of transmural extent. For free-breathing LGE, readers graded scans with good/excellent IQ in 80.0%, with low-impact/no artifacts in 78.6%, and with good/high DC in 82.1% of cases. Elevated BMI was associated with increased artifacts (P = .0012) and decreased IQ (P = .0237). Increased heart rate negatively influenced artifacts (P = .0013) and DC (P = .0479) whereas IQ (P = .3025) was unimpaired. CONCLUSIONS: In a clinical setting, free-breathing Compressed SENSE accelerated 3D high isotropic spatial resolution whole heart LGE provides good to excellent image quality in 80% of scans independent of heart rate while enabling improved depiction of small and particularly non-ischemic hyperenhanced lesions in a shorter scan time than standard breath-hold LGE.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Meios de Contraste , Ventrículos do Coração/diagnóstico por imagem , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética , Miocárdio/patologia , Compostos Organometálicos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cardiomiopatias/patologia , Bases de Dados Factuais , Feminino , Ventrículos do Coração/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sobrevivência de Tecidos , Adulto Jovem
3.
J Cardiovasc Magn Reson ; 22(1): 16, 2020 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-32085782

RESUMO

The original publication of this article [1], contained graphical errors in Figs. 1 and 2. This does not impact the display of the mean differences of the Bland-Altman plots. The updated figures (Fig. 1 and Fig. 2) are published in this correction article.

4.
J Cardiovasc Magn Reson ; 22(1): 8, 2020 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-31969137

RESUMO

BACKGROUND: Patients with Congenital heart disease (CHD) require repetitive imaging of the pulmonary vasculature throughout their life. In this study, we compared a novel Compressed SENSE accelerated (factor 9) electrocardiogram (ECG)- and respiratory-triggered 3D modified Relaxation-Enhanced Angiography without Contrast and Triggering (modified REACT-non-contrast-enhanced magnetic resonance angiography (modified REACT-non-CE-MRA)) with standard non-ECG-triggered time-resolved 4D CE-MRA for imaging of the pulmonary arteries and veins in patients with CHD. METHODS: This retrospective analysis of 25 patients (June 2018-April 2019) with known or suspected CHD was independently conducted by two radiologists executing measurements on modified REACT-non-CE-MRA and 4D CE-MRA on seven dedicated points (inner edge): Main pulmonary artery (MPA), right and left pulmonary artery, right superior and inferior pulmonary vein, left superior (LSPV) and inferior pulmonary vein. Image quality for arteries and veins was evaluated on a four-point scale in consensus. RESULTS: Twenty-three of the 25 included patients presented a CHD. There was a high interobserver agreement for both methods of imaging at the pulmonary arteries (ICC ≥ 0.96); at the pulmonary veins, modified REACT-non-CE-MRA showed a slightly higher agreement, pronounced at LSPV (ICC 0.946 vs. 0.895). Measurements in 4D CE-MRA showed higher diameter values compared to modified REACT-non-CE-MRA, at the pulmonary arteries reaching significant difference (e.g. MPA: mean 0.408 mm, p = 0.002). Modified REACT-non-CE-MRA (average acquisition time 07:01 ± 02:44 min) showed significant better image quality than 4D CE-MRA at the pulmonary arteries (3.84 vs. 3.32, p < 0.001) and veins (3.32 vs. 2.72, p = 0.015). CONCLUSIONS: Compressed SENSE accelerated (factor 9) ECG- and respiratory-triggered 3D modified REACT-non-CE-MRA allows for reliable and fast imaging of the pulmonary arteries and veins with higher image quality and slightly higher interobserver agreement than 4D CE-MRA without contrast agent and associated disadvantages. Therefore, it represents a clinically suitable technique for patients requiring repetitive imaging of the pulmonary vasculature, e.g. patients with CHD.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Cardiopatias Congênitas/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Angiografia por Ressonância Magnética , Artéria Pulmonar/diagnóstico por imagem , Veias Pulmonares/diagnóstico por imagem , Adulto , Bases de Dados Factuais , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
5.
Thorac Cardiovasc Surg ; 67(2): 86-91, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-29080557

RESUMO

BACKGROUND: Temporary transmyocardial pacing leads (TTPLs) represent an absolute contraindication to magnetic resonance imaging (MRI). The purpose of this study was to evaluate the safety and feasibility of MRI at 1.5 Tesla (T) using a transmit/receive (T/R) head coil in patients with TTPL. METHODS: TTPLs (220 cm, Osypka TME, Dr. Osypka GmbH, Rheinfelden, Germany) were implanted in a phantom and exposed to conditions of a 1.5 T brain examination using a T/R head coil. Temperature changes at the lead tip were continuously recorded. A total of 28 patients with TTPL and an urgent indication for a brain MRI underwent MRI at 1.5 T with vital sign monitoring. A T/R head coil was used to minimize radiofrequency exposure of the TTPL. Before and immediately after the MRI scan, TTPL lead impedance, pacing capture threshold (PCT), signal slope, and sensing were measured. Serum troponin I was determined before and after MRI to detect thermal myocardial injury. RESULTS: In vitro, the maximum temperature increase from radiofrequency-induced heating of the TTPL tip was < 1°C. In vivo, no complications, such as heating sensations, dizziness, unexpected changes in heart rate or rhythm, or other unusual signs or symptoms were observed. No significant changes in the lead impedance, PCT, signal slope, or sensing were recorded. There were no increases of serum troponin I after the MRI examination. CONCLUSIONS: MRI of the brain may be performed safely at 1.5 T using a T/R head coil in case of an urgent clinical need in patients with TTPL and may be considered a feasible and safe procedure when appropriate precautionary measures are taken.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Marca-Passo Artificial , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Imagem de Difusão por Ressonância Magnética/efeitos adversos , Imagem de Difusão por Ressonância Magnética/instrumentação , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Segurança do Paciente , Imagens de Fantasmas , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco , Troponina I/sangue
6.
Catheter Cardiovasc Interv ; 91(4): 774-782, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28547872

RESUMO

OBJECTIVES: To investigate the impact of aortic valve calcification and brain morphology on acute peri-procedural cerebrovascular events (CVEs) in patients undergoing transcatheter aortic valve implantation (TAVI). BACKGROUND: Aortic valve calcification and stenosis can be assessed with echocardiography. Cerebral magnetic resonance imaging (MRI) depicts and quantifies morphological signs of hypoperfusion and vascular embolism, which is of special interest in patients with severe aortic stenosis. Furthermore, subjects who undergo TAVI are prone to suffer of clinically silent peri-procedural CVEs. METHODS: A total of 119 patients referred to TAVI were investigated for aortic valve calcification using trans-esophageal echocardiography. Cerebral MRI prior to and immediate after implantation was performed in all patients using a dedicated scan protocol. Prior to TAVI, brain morphology was characterized. Post TAVI, brains were investigated for the onset of acute peri-procedural CVEs using diffusion weighted imaging (DWI). RESULTS: Seventy-eight patients (65.5%) revealed acute peri-procedural CVEs on MRI after TAVI with a favor of the left hemisphere (57.5%). The degree of valve calcification was associated with peri-procedural CVEs. Patients with a high WML burden had an increased risk for CVEs ((OR) 2.36 (95% CI: 1.09-5.15; P = 0.037)), especially when distributed periventricular ((OR: 3.27; 95% CI: 1.47-7.26; P = 0.0038)). CONCLUSION: In patients undergoing TAVI, the degree of aortic valve calcification and periventricular WML burden were correlated with acute peri-procedural CVEs. Future studies are needed to evaluate their independent value for the long-term clinical outcome.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Calcinose/cirurgia , Transtornos Cerebrovasculares/etiologia , Leucoencefalopatias/complicações , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Doenças Assintomáticas , Calcinose/complicações , Calcinose/diagnóstico por imagem , Calcinose/fisiopatologia , Transtornos Cerebrovasculares/diagnóstico por imagem , Transtornos Cerebrovasculares/fisiopatologia , Imagem de Difusão por Ressonância Magnética , Ecocardiografia Transesofagiana , Feminino , Hemodinâmica , Humanos , Leucoencefalopatias/diagnóstico por imagem , Masculino , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
7.
Eur Radiol ; 27(11): 4661-4671, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28500369

RESUMO

OBJECTIVES: To investigate the diagnostic value of cardiac magnetic resonance (CMR) feature-tracking (FT) myocardial strain analysis in patients with suspected acute myocarditis and its association with myocardial oedema. METHODS: Forty-eight patients with suspected acute myocarditis and 35 control subjects underwent CMR. FT CMR analysis of systolic longitudinal (LS), circumferential (CS) and radial strain (RS) was performed. Additionally, the protocol allowed for the assessment of T1 and T2 relaxation times. RESULTS: When compared with healthy controls, myocarditis patients demonstrated reduced LS, CS and RS values (LS: -19.5 ± 4.4% vs. -23.6 ± 3.1%, CS: -23.0 ± 5.8% vs. -27.4 ± 3.4%, RS: 28.9 ± 8.5% vs. 32.4 ± 7.4%; P < 0.05, respectively). LS (T1: r = 0.462, P < 0.001; T2: r = 0.436, P < 0.001) and CS (T1: r = 0.429, P < 0.001; T2: r = 0.467, P < 0.001) showed the strongest correlations with T1 and T2 relaxations times. Area under the curve of LS (0.79) was higher compared with those of CS (0.75; P = 0.478) and RS (0.62; P = 0.008). CONCLUSIONS: FT CMR myocardial strain analysis might serve as a new tool for assessment of myocardial dysfunction in the diagnostic work-up of patients suspected of having acute myocarditis. Especially, LS and CS show a sufficient diagnostic performance and were most closely correlated with CMR parameters of myocardial oedema. KEY POINTS: • Myocardial strain measures are considerably reduced in patients with suspected myocarditis. • Myocardial strain measures can sufficiently discriminate between diseased and healthy patients. • Myocardial strain measures show basic associations with the extent of myocardial oedema/inflammation.


Assuntos
Edema Cardíaco/diagnóstico por imagem , Miocardite/diagnóstico por imagem , Doença Aguda , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Edema Cardíaco/fisiopatologia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Miocardite/fisiopatologia , Estudos Prospectivos , Volume Sistólico/fisiologia , Sístole , Adulto Jovem
8.
J Comput Assist Tomogr ; 41(4): 572-577, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28240633

RESUMO

OBJECTIVE: To evaluate the effectiveness and clinical utility of a metal artifact reduction (MAR) image reconstruction algorithm for the reduction of high-attenuation object (HAO)-related image artifacts. METHODS: Images were quantitatively evaluated for image noise (noiseSD and noiserange) and qualitatively for artifact severity, gray-white-matter delineation, and diagnostic confidence with conventional reconstruction and after applying a MAR algorithm. RESULTS: Metal artifact reduction reduces noiseSD and noiserange (median [interquartile range]) at the level of HAO in 1-cm distance compared with conventional reconstruction (noiseSD: 60.0 [71.4] vs 12.8 [16.1] and noiserange: 262.0 [236.8] vs 72.0 [28.3]; P < 0.0001). Artifact severity (reader 1 [mean ± SD]: 1.1 ± 0.6 vs 2.4 ± 0.5, reader 2: 0.8 ± 0.6 vs 2.0 ± 0.4) at level of HAO and diagnostic confidence (reader 1: 1.6 ± 0.7 vs 2.6 ± 0.5, reader 2: 1.0 ± 0.6 vs 2.3 ± 0.7) significantly improved with MAR (P < 0.0001). Metal artifact reduction did not affect gray-white-matter delineation. CONCLUSIONS: Metal artifact reduction effectively reduces image artifacts caused by HAO and significantly improves diagnostic confidence without worsening gray-white-matter delineation.


Assuntos
Algoritmos , Artefatos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
9.
J Vasc Surg ; 61(5): 1312-20, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-24418637

RESUMO

OBJECTIVE: Noninvasive measurement of peripheral muscle microperfusion could potentially improve diagnosis, management, and treatment of peripheral arterial disease (PAD) and thus improve patient care. Contrast-enhanced ultrasound (CEUS) as a noninvasive diagnostic tool allows quantification of muscle perfusion. Increasing data on bolus technique CEUS reflecting microperfusion are becoming available, but only limited data on steady-state CEUS for assessment of muscle microperfusion are available. Therefore, the aim of this study was to evaluate steady-state CEUS for assessment of peripheral muscle microperfusion in a PAD animal model. METHODS: In a porcine animal model, peripheral muscle microperfusion was quantified by steady-state CEUS replenishment kinetics (mean transit time [mTT] and wash-in rate [WiR]) of the biceps femoris muscle during intravenous steady-state infusion of INN-sulfur hexafluoride (SonoVue; Bracco, Geneva, Switzerland). In addition, macroperfusion was quantified at the external femoral artery with a Doppler flow probe. Peripheral muscle microperfusion and Doppler flow measurements were performed bilaterally at rest and under adenosine stress (70 µg/kg body weight) before and after unilateral creation of a moderate external iliac artery stenosis. RESULTS: All measurements could be performed completely in 10 pigs. Compared with baseline measurements, peripheral muscle microperfusion decreased significantly during adenosine stress (rest vs adenosine stress: mTT, 7.8 ± 3.3 vs 21.2 ± 17.8 s, P = .0006; WiR, 58.4 ± 38.1 vs 25.3 ± 15.6 arbitrary units [a.u.]/s, P < .0001; Doppler flow, 122.3 ± 31.4 vs 83.6 ± 28.1 mL/min, P = .0067) and after stenosis creation (no stenosis vs stenosis: mTT, 8.1 ± 3.1 vs 29.2 ± 18.0 s, P = .0469; WiR, 53.0 ± 22.7 vs 13.6 ± 8.4 a.u./s, P = .0156; Doppler flow, 124.2 ± 41.8 vs 65.9 ± 40.0 mL/min, P = .0313). After stenosis creation, adenosine stress led to a further significant decrease of peripheral muscle microperfusion but had no effect on macroperfusion (mTT, 29.2 ± 18.0 vs 56.3 ± 38.7 s, P = .0078; WiR, 13.6 ± 8.4 vs 6.0 ± 4.1 a.u./s, P = .0078; Doppler flow, 65.9 ± 40.0 vs 79.2 ± 29.6 mL/min, P = .8125). Receiver operating characteristic curves for the presence of inflow stenosis showed an excellent area under the curve of 0.93 for mTT at rest and 0.86 for Doppler flow. CONCLUSIONS: Peripheral muscle microperfusion measurement by steady-state CEUS with replenishment kinetics is feasible and allows detection of muscle microperfusion changes caused by vasodilative stress alone or in combination with a moderate inflow stenosis. Steady-state CEUS offers superior diagnostic performance compared with Doppler flow measurements. Therefore, steady-state CEUS may prove to be a useful tool in diagnosis of PAD and for evaluation of new therapies.


Assuntos
Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/fisiopatologia , Velocidade do Fluxo Sanguíneo/fisiologia , Meios de Contraste , Modelos Animais de Doenças , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/fisiopatologia , Isquemia/diagnóstico por imagem , Isquemia/fisiopatologia , Microcirculação/fisiologia , Músculo Esquelético/irrigação sanguínea , Fosfolipídeos , Hexafluoreto de Enxofre , Adenosina , Animais , Pressão Sanguínea/fisiologia , Feminino , Frequência Cardíaca/fisiologia , Masculino , Suínos , Ultrassonografia
10.
J Vasc Interv Radiol ; 26(9): 1396-402.e2, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26190189

RESUMO

PURPOSE: To determine the effects of catheter-based peripheral sympathetic denervation (CPSD) on peripheral artery sympathetic tone and peripheral microperfusion (PMP). MATERIALS AND METHODS: The effects of bilateral CPSD in common iliac arteries on PMP of the biceps femoris were determined in pigs using contrast-enhanced ultrasound, and mean transit time (mTT) and wash-in rate (WiR) were calculated during steady-state infusion of INN-sulfur-hexafluoride. Measurements were performed bilaterally at rest and during infusion of adenosine 70 µg/kg/min after unilateral moderate left external iliac artery stenosis. RESULTS: Before CPSD, PMP decreased significantly (P < .05) under adenosine stress compared with resting conditions, with right mTT of 7.5 seconds ± 3.6 versus 16.9 seconds ± 11.9 and WiR of 63.1 arbitrary units (AU) ± 49.0 versus 25.0 AU ± 17.5 and left mTT of 29.2 seconds ± 18.0 versus 56.3 seconds ± 38.7 and WiR of 13.6 AU ± 8.4 versus 6.0 AU ± 4.1. After CPSD, PMP did not differ significantly (P > .05) between conditions of adenosine stress and rest, with right mTT of 19.9 seconds ± 24.7 versus 23.2 seconds ± 21.0 and WiR of 16.2 AU ± 25.0 versus 20.5 AU ± 19.7 and left mTT of 23.3 seconds ± 23.1 versus 25.8 seconds ± 21.7 and WiR of 12.5 AU ± 6.2 versus 20.0 AU ± 12.1. CONCLUSIONS: CPSD reduced peripheral artery sympathetic tone and may be an alternative to surgical or computed tomography-guided sympathectomy for the treatment of end-stage peripheral artery disease and Raynaud phenomenon.


Assuntos
Músculo Esquelético/irrigação sanguínea , Músculo Esquelético/fisiopatologia , Doença Arterial Periférica/fisiopatologia , Doença Arterial Periférica/cirurgia , Simpatectomia/métodos , Animais , Velocidade do Fluxo Sanguíneo , Meios de Contraste , Músculo Esquelético/diagnóstico por imagem , Suínos , Resultado do Tratamento , Ultrassonografia Doppler
11.
J Cardiovasc Magn Reson ; 17: 12, 2015 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-25885268

RESUMO

BACKGROUND: Quantitative Cardiovascular Magnetic Resonance (CMR) techniques have gained high interest in CMR research. Myocardial T2 mapping is thought to be helpful in diagnosis of acute myocardial conditions associated with myocardial edema. In this study we aimed to establish a technique for myocardial T2 mapping based on gradient-spin-echo (GraSE) imaging. METHODS: The local ethics committee approved this prospective study. Written informed consent was obtained from all subjects prior to CMR. A modified GraSE sequence allowing for myocardial T2 mapping in a single breath-hold per slice using ECG-triggered acquisition of a black blood multi-echo series was developed at 1.5 Tesla. Myocardial T2 relaxation time (T2-RT) was determined by maximum likelihood estimation from magnitude phased-array multi-echo data. Four GraSE sequence variants with varying number of acquired echoes and resolution were evaluated in-vitro and in 20 healthy volunteers. Inter-study reproducibility was assessed in a subset of five volunteers. The sequence with the best overall performance was further evaluated by assessment of intra- and inter-observer agreement in all volunteers, and then implemented into the clinical CMR protocol of five patients with acute myocardial injury (myocarditis, takotsubo cardiomyopathy and myocardial infarction). RESULTS: In-vitro studies revealed the need for well defined sequence settings to obtain accurate T2-RT measurements with GraSE. An optimized 6-echo GraSE sequence yielded an excellent agreement with the gold standard Carr-Purcell-Meiboom-Gill sequence. Global myocardial T2 relaxation times in healthy volunteers was 52.2 ± 2.0 ms (mean ± standard deviation). Mean difference between repeated examinations (n = 5) was -0.02 ms with 95% limits of agreement (LoA) of [-4.7; 4.7] ms. Intra-reader and inter-reader agreement was excellent with mean differences of -0.1 ms, 95% LoA = [-1.3; 1.2] ms and 0.1 ms, 95% LoA = [-1.5; 1.6] ms, respectively (n = 20). In patients with acute myocardial injury global myocardial T2-RTs were prolonged (mean: 61.3 ± 6.7 ms). CONCLUSION: Using an optimized GraSE sequence CMR allows for robust, reliable, fast myocardial T2 mapping and quantitative tissue characterization. Clinically, the GraSE-based T2-mapping has the potential to complement qualitative CMR in patients with acute myocardial injuries.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Contração Miocárdica , Infarto do Miocárdio/diagnóstico , Miocardite/diagnóstico , Cardiomiopatia de Takotsubo/diagnóstico , Adolescente , Adulto , Idoso , Feminino , Voluntários Saudáveis , Humanos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Miocardite/fisiopatologia , Variações Dependentes do Observador , Imagens de Fantasmas , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Cardiomiopatia de Takotsubo/fisiopatologia , Adulto Jovem
12.
Radiology ; 273(2): 383-92, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24910904

RESUMO

PURPOSE: To evaluate the diagnostic value of cardiac magnetic resonance (MR) imaging at 3 T in patients suspected of having acute myocarditis by using a multiparametric cardiac MR imaging approach including T1 relaxation time as an additional tool for tissue characterization. MATERIALS AND METHODS: Ethics commission approval was obtained for this prospective study, and written informed consent was obtained from all subjects. Twenty four patients with acute myocarditis (mean age ± standard deviation, 34.7 years ± 15.1; 75% men) and 42 control subjects (mean age, 38.7 years ± 10.2; 64% men) were included. Cardiac MR imaging approaches included relative T2 short tau inversion-recovery signal intensity ratio (T2 ratio), early gadolinium enhancement ratio, late gadolinium enhancement, native T1 relaxation times, and extracellular volume fraction. Receiver operating characteristic analysis was performed to compare diagnostic performance. The reference standard was the clinical evidence for acute myocarditis. RESULTS: Native T1 relaxation times were significantly longer in patients with acute myocarditis than in control subjects (1185.3 msec ± 49.3 vs 1089.1 msec ± 44.9, respectively; P < .001). Areas under the curve of native T1 relaxation times (0.94) were higher compared with those of other cardiac MR parameters (late gadolinium enhancement, 0.90; T2 ratio, 0.79; extracellular volume fraction, 0.71; early gadolinium enhancement ratio, 0.63; P = .390, .018, .002, and < .001, respectively). Sensitivity (92%), specificity (91%), and diagnostic accuracy (91%) for native T1 relaxation times (cutoff, 1140 msec) were equivalent compared with those of the established combined Lake Louise criteria (sensitivity, 92%; specificity, 80%; diagnostic accuracy, 85%). CONCLUSION: Diagnostic performance with native T1 mapping was superior to that with T2 ratio and early gadolinium enhancement ratio, and specificity was higher with native T1 mapping than that with Lake Louise criteria. This study underlines the potential of native T1 relaxation times to complement current cardiac MR approaches in patients suspected of having acute myocarditis.


Assuntos
Imageamento por Ressonância Magnética/métodos , Miocardite/diagnóstico , Doença Aguda , Adulto , Idoso , Biomarcadores/sangue , Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste , Diagnóstico Diferencial , Ecocardiografia , Eletrocardiografia , Teste de Esforço , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
13.
J Vasc Interv Radiol ; 24(5): 698-702, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23622041

RESUMO

PURPOSE: To retrospectively evaluate the safety and effectiveness of the EXOSEAL vascular closure device (VCD) for first or repeated closure after retrograde percutaneous femoral arterial access. MATERIALS AND METHODS: A retrospective analysis of 417 patients (271 men; mean age, 64.1 y±12.8; age range, 22-94 y) who had undergone arterial closure with the EXOSEAL VCD was performed. Procedures with retrograde femoral access and closure with the 5-F, 6-F, or 7-F EXOSEAL VCD according to the manufacturer's instructions were included. The clinical indications included the full procedural portfolio of a radiologic department with a focus on transarterial hepatic procedures. After EXOSEAL VCD closure, patients were restricted to bed rest for 4 hours. RESULTS: From August 2010 to March 2012, a total of 682 EXOSEAL VCDs (5-F, n = 276; 6-F, n = 394; 7-F, n = 12) were used in 659 procedures with a total of 404 repeated closures. The EXOSEAL VCD was used successfully in 676 of 682 procedures (99.1%). Hemostasis was achieved in 651 of 682 procedures (95.5%). No major complications were encountered. There were eight cases (1.17%) of minor complications despite a successful vascular closure procedure, none requiring further therapy. There were no complications in any of the 404 cases of repeated vascular closure. CONCLUSIONS: The results of this study suggest that the EXOSEAL VCD is safe and effective in single and repeated closure of retrograde percutaneous femoral arterial access in interventional radiology cases.


Assuntos
Artéria Femoral/cirurgia , Hemostasia Cirúrgica/instrumentação , Técnicas Hemostáticas/instrumentação , Complicações Pós-Operatórias/epidemiologia , Punções/instrumentação , Radiografia Intervencionista/instrumentação , Dispositivos de Acesso Vascular/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Artéria Femoral/diagnóstico por imagem , Alemanha/epidemiologia , Hemostasia Cirúrgica/estatística & dados numéricos , Técnicas Hemostáticas/estatística & dados numéricos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Punções/estatística & dados numéricos , Radiografia Intervencionista/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Adulto Jovem
14.
Rofo ; 195(2): 115-134, 2023 02.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-36634682

RESUMO

This position paper is a joint statement of the German Radiological Society (DRG) and the Professional Association of German Radiologists (BDR), which reflects the current state of knowledge about coronary computed tomography. It is based on preclinical and clinical studies that have investigated the clinical relevance as well as the technical requirements and fundamentals of cardiac computed tomography. CITATION FORMAT: · Langenbach MC, Sandstede J, Sieren M et al. DRG and BDR Position Paper on Coronary CT: Clinical Evidence and Quality of Patient Care in Chronic Coronary Syndrome. Fortschr Röntgenstr 2023; 195: 115 - 133.


Assuntos
Radiologia , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Coração , Radiologistas , Assistência ao Paciente
15.
Front Cardiovasc Med ; 10: 1305649, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38099228

RESUMO

Aim: The purpose of this study was to investigate the clinical application of Compressed SENSE accelerated single-breath-hold LGE with 3D isotropic resolution compared to conventional LGE imaging acquired in multiple breath-holds. Material & Methods: This was a retrospective, single-center study including 105 examinations of 101 patients (48.2 ± 16.8 years, 47 females). All patients underwent conventional breath-hold and 3D single-breath-hold (0.96 × 0.96 × 1.1 mm3 reconstructed voxel size, Compressed SENSE factor 6.5) LGE sequences at 1.5 T in clinical routine for the evaluation of ischemic or non-ischemic cardiomyopathies. Two radiologists independently evaluated the left ventricle (LV) for the presence of hyperenhancing lesions in each sequence, including localization and transmural extent, while assessing their scar edge sharpness (SES). Confidence of LGE assessment, image quality (IQ), and artifacts were also rated. The impact of LV ejection fraction (LVEF), heart rate, body mass index (BMI), and gender as possible confounders on IQ, artifacts, and confidence of LGE assessment was evaluated employing ordinal logistic regression analysis. Results: Using 3D single-breath-hold LGE readers detected more hyperenhancing lesions compared to conventional breath-hold LGE (n = 246 vs. n = 216 of 1,785 analyzed segments, 13.8% vs. 12.1%; p < 0.0001), pronounced at subendocardial, midmyocardial, and subepicardial localizations and for 1%-50% of transmural extent. SES was rated superior in 3D single-breath-hold LGE (4.1 ± 0.8 vs. 3.3 ± 0.8; p < 0.001). 3D single-breath-hold LGE yielded more artifacts (3.8 ± 1.0 vs. 4.0 ± 3.8; p = 0.002) whereas IQ (4.1 ± 1.0 vs. 4.2 ± 0.9; p = 0.122) and confidence of LGE assessment (4.3 ± 0.9 vs. 4.3 ± 0.8; p = 0.374) were comparable between both techniques. Female gender negatively influenced artifacts in 3D single-breath-hold LGE (p = 0.0028) while increased heart rate led to decreased IQ in conventional breath-hold LGE (p = 0.0029). Conclusions: In clinical routine, Compressed SENSE accelerated 3D single-breath-hold LGE yields image quality and confidence of LGE assessment comparable to conventional breath-hold LGE while providing improved delineation of smaller LGE lesions with superior scar edge sharpness. Given the fast acquisition of 3D single-breath-hold LGE, the technique holds potential to drastically reduce the examination time of CMR.

16.
Radiology ; 263(1): 77-85, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22371610

RESUMO

PURPOSE: To evaluate the effect of dual-source parallel radiofrequency (RF) transmission with patient-adaptive local RF shimming on image quality, image contrast, and diagnostic confidence at routine clinical cardiac magnetic resonance (MR) imaging with use of a 3.0-T dual-channel transmit whole-body MR system. MATERIALS AND METHODS: Written informed consent was obtained from all patients, and the study protocol was approved by the local institutional review board. Cardiac MR imaging was performed in 28 patients by using a 3.0-T MR unit equipped with a dual-source RF transmission system. The effect of conventional versus dual-source RF transmission on steady-state free precession (SSFP) cine sequences and turbo spin-echo (TSE) black-blood (BB) sequences was evaluated. The homogeneity of the B1 field and contrast-to-noise ratios (CNRs) were measured and tested for statistical significance with the paired t test. Images were analyzed qualitatively for homogeneity, the presence of off-resonance artifacts, and diagnostic confidence independently by two readers. Statistical significance was assessed with the Wilcoxon signed rank test. Inter- and intraobserver agreement was assessed with κ statistics. RESULTS: Quantitative image analysis revealed that B1 homogeneity and CNR were significantly improved for images acquired with dual-source RF transmission compared with conventional RF transmission (P = .005). The quality of SSFP and TSE BB images of the left and the right ventricles showed a significant improvement with respect to image homogeneity and diagnostic confidence as evaluated by the readers (P = .0001, κ > 0.74). As a side effect, off-resonance artifacts were significantly reduced on SSFP images (P = .0001, κ > 0.76). CONCLUSION: Dual-source parallel RF transmission significantly improves image homogeneity, image contrast, and diagnostic confidence compared with conventional RF transmission of cardiac SSFP and TSE BB sequences.


Assuntos
Cardiomiopatias/diagnóstico , Doença das Coronárias/diagnóstico , Imagem Cinética por Ressonância Magnética/métodos , Adulto , Idoso , Análise de Variância , Artefatos , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Ondas de Rádio , Estatísticas não Paramétricas
17.
J Cardiovasc Magn Reson ; 14: 75, 2012 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-23107424

RESUMO

BACKGROUND: Using first-pass MRA (FP-MRA) spatial resolution is limited by breath-hold duration. In addition, image quality may be hampered by respiratory and cardiac motion artefacts. In order to overcome these limitations an ECG- and navigator-gated high-resolution-MRA sequence (HR-MRA) with slow infusion of extracellular contrast agent was implemented at 3 Tesla for the assessment of congenital heart disease and compared to standard first-pass-MRA (FP-MRA). METHODS: 34 patients (median age: 13 years) with congenital heart disease (CHD) were prospectively examined on a 3 Tesla system. The CMR-protocol comprised functional imaging, FP- and HR-MRA, and viability imaging. After the acquisition of the FP-MRA sequence using a single dose of extracellular contrast agent the motion compensated HR-MRA sequence with isotropic resolution was acquired while injecting the second single dose, utilizing the timeframe before viability imaging. Qualitative scores for image quality (two independent reviewers) as well as quantitative measurements of vessel sharpness and relative contrast were compared using the Wilcoxon signed-rank test. Quantitative measurements of vessel diameters were compared using the Bland-Altman test. RESULTS: The mean image quality score revealed significantly better image quality of the HR-MRA sequence compared to the FP-MRA sequence in all vessels of interest (ascending aorta (AA), left pulmonary artery (LPA), left superior pulmonary vein (LSPV), coronary sinus (CS), and coronary ostia (CO); all p < 0.0001). In comparison to FP-MRA, HR-MRA revealed significantly better vessel sharpness for all considered vessels (AA, LSPV and LPA; all p < 0.0001). The relative contrast of the HR-MRA sequence was less compared to the FP-MRA sequence (AA: p <0.028, main pulmonary artery: p <0.004, LSPV: p <0.005). Both, the results of the intra- and interobserver measurements of the vessel diameters revealed closer correlation and closer 95 % limits of agreement for the HR-MRA. HR-MRA revealed one additional clinical finding, missed by FP-MRA. CONCLUSIONS: An ECG- and navigator-gated HR-MRA-protocol with infusion of extracellular contrast agent at 3 Tesla is feasible. HR-MRA delivers significantly better image quality and vessel sharpness compared to FP-MRA. It may be integrated into a standard CMR-protocol for patients with CHD without the need for additional contrast agent injection and without any additional examination time.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste , Cardiopatias Congênitas/diagnóstico , Angiografia por Ressonância Magnética , Compostos Organometálicos , Adolescente , Artefatos , Suspensão da Respiração , Criança , Meios de Contraste/administração & dosagem , Eletrocardiografia , Feminino , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/cirurgia , Frequência Cardíaca , Humanos , Lactente , Infusões Intravenosas , Masculino , Variações Dependentes do Observador , Compostos Organometálicos/administração & dosagem , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Respiração , Fatores de Tempo
18.
Rofo ; 194(2): 181-191, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34384112

RESUMO

PURPOSE: In the light of the increasing importance of cardiovascular cross-sectional imaging in current guidelines, the goal of this study is to provide a comprehensive overview of cardiovascular imaging (CVI) offered by radiological institutions across Germany. MATERIALS AND METHODS: Data were extracted from the national certification program database of the German Roentgen Society (DRG) from 2015-2021. A nationwide online survey among radiology institutes (university hospitals, non-university hospitals, and private practices) was conducted for 2019, and data was extracted from the European Society of Cardiovascular Radiology (ESCR) registry. The data collection's key points included the number of centers and individuals certified for CVI, the number of cardiac CT and MRI examinations performed, the reporting habits, and the participation in the ESCR registry. RESULTS: 71 centers and 1278 persons, both with a substantial increase since 2015, were registered and certified by the DRG to perform CVI. According to the survey, a total of 69,286 CT and 64,281 MRI examinations were performed annually. Data from the survey and the ESCR registry indicated that reporting was mostly done solely by radiologists or, to a lesser degree, in joint consensus meetings with non-radiologists. The overall participation rate in the ESCR registry was 48 % among the survey's participants. CONCLUSION: This comprehensive analysis demonstrates that high-quality CVI by radiologists is available nationwide. The current challenges are to provide the best medical and technical quality of CVI by radiology for patient care and to ensure economic sustainability in the German health care system to accommodate the predicted substantial need for CVI in the future. KEY POINTS: · High-quality advanced CVI service by radiologists is available nationwide.. · Highly qualified specialist knowledge is widely represented from university to private practices.. · Certification programs successfully contribute to the dissemination & deepening of CVI expertise.. · The ESCR registry is an established international tool for the documentation of CVI.. CITATION FORMAT: · Sieren M, Maintz D, Gutberlet M et al. Current Status of Cardiovascular Imaging in Germany: Structured Data from the National Certification Program, ESCR Registry, and Survey among Radiologists. Fortschr Röntgenstr 2022; 194: 181 - 191.


Assuntos
Radiologia , Certificação , Alemanha , Humanos , Imageamento por Ressonância Magnética/métodos , Radiologistas , Sistema de Registros
19.
Am Heart J ; 161(6): 1096-105, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21641356

RESUMO

BACKGROUND: Recent studies suggest that magnetic resonance (MR) imaging of the brain and spine may safely be performed in patients with pacemakers (PMs) and implantable cardioverter/defibrillators (ICDs), when taking adequate precautions. The aim of this study was to investigate safety, feasibility, and diagnostic value (DV) of MR imaging in cardiac applications (cardiac MR [CMR]) in patients with PMs and ICDs for the first time. METHODS: Thirty-two PM/ICD patients with a clinical need for CMR were examined. The specific absorption rate was limited to 1.5 W/kg. Devices were reprogrammed pre-CMR to minimize interference with the electromagnetic fields. Devices were interrogated pre-CMR and post-CMR and after 3 months. Troponin I levels were measured pre-CMR and post-CMR; image quality (IQ) and DV of CMR were assessed. RESULTS: All devices could be reprogrammed normally post-CMR. No significant changes of pacing capture threshold, lead impedance, and troponin I were observed. Image quality in patients with right-sided devices (RSD) was better compared with that in patients with left-sided devices (LSD) (P < .05), and less myocardial segments were affected by device-related artefacts (P < .05). Diagnostic value was rated as sufficiently high, allowing for diagnosis, or better in 12 (100%) of 12 patients with RSD, and only in 7 (35%) of 20 patients with LSD. CONCLUSIONS: Cardiac MR may be performed safely when limiting specific absorption rate, appropriately monitoring patients, and following device reprogramming. Cardiac MR delivers good IQ and DV in patients with RSD. Cardiac MR in patients with RSD may therefore be performed with an acceptable risk/benefit ratio, whereas the risk/benefit ratio is rather unfavorable in patients with LSD.


Assuntos
Desfibriladores Implantáveis , Imageamento por Ressonância Magnética , Marca-Passo Artificial , Troponina I/sangue , Adulto , Idoso , Artefatos , Estimulação Cardíaca Artificial , Contraindicações , Técnicas de Imagem por Elasticidade , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio , Adulto Jovem
20.
Pacing Clin Electrophysiol ; 34(6): 684-9, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21303390

RESUMO

BACKGROUND: Little is known about the prevalence of upper extremity vein obstruction or anomalies in patients before first implantation of implantable cardioverter defibrillator (ICD). It remains unclear in which patients contrast venography is warranted before implantation procedure. METHODS: Results of clinical data and contrast venography of 302 consecutive patients scheduled for first ICD implantation were analyzed. RESULTS: Prevalence of upper vein obstruction was 6.6% (20/302 patients) in a typical patient population undergoing first ICD implantation. Age, left ventricular ejection fraction, underlying heart disease, prior open-heart surgery, or cardiopulmonary resuscitation were not predictors of obstruction. Patients with previous cardiac pacemaker implantation had a higher rate of obstruction, though this was not statistically significant (20% vs 15.7%, P = 0.54). Persistent left vena cava was found in 0.7%. CONCLUSION: There is no clinical parameter sufficient enough to predict upper extremity venous obstruction. Contrast venography may be considered in patients with previous pacemaker placement but should not be a routine diagnostic tool in unselected patients prior to first ICD-implantation procedure.


Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Falha de Prótese , Implantação de Prótese/estatística & dados numéricos , Extremidade Superior/irrigação sanguínea , Insuficiência Venosa/epidemiologia , Feminino , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Medição de Risco , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA