1.
J Cardiovasc Electrophysiol ; 35(7): 1382-1392, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38725252

RESUMO

INTRODUCTION: Reports of comparison with procedural outcomes for implantable cardioverter defibrillator (ICD) and pacemaker (PM) transvenous lead extraction (TLE) are old and limited. We sought to compare the safety, efficacy, and procedural properties of ICD and PM TLE and assess the impact of lead age. METHODS: The study cohort included all consecutive patients with ICD and PM TLE in the Cleveland Clinic Prospective TLE Registry between 2013 and 2022. Extraction success, complications, and failure employed the definitions described in the HRS 2017 TLE guidelines. RESULTS: A total of 885 ICD leads, a median implant duration of 8 (5-11) years in 810 patients, and 1352 PM leads of 7 (3-13) years in 807 patients were included. Procedural success rates in ICD patients were superior to those of PM in >20 years leads but similar in ≤20 years leads. In the PM group, the complete success rate of TLE decreased significantly according to the increase of lead age, but not in the ICD group. ICD TLE required more extraction tools compared with PM TLE but cases with older leads required non-laser sheath extraction tools in both groups. The most common injury site in major complication cases differed between ICD and PM TLE, although major complication rates showed no difference in both groups (2.7% vs. 1.6%, p = .12). CONCLUSION: The procedural success rate by TLE is greater for ICD patients than PM patients with leads >20 years old but requires more extraction tools. Common vascular complication sites and the impact of lead age on procedural outcomes and required tools differed between ICD and PM TLE.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo , Marca-Passo Artificial , Sistema de Registros , Humanos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Remoção de Dispositivo/efeitos adversos , Resultado do Tratamento , Fatores de Tempo , Fatores de Risco , Ohio , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Hospitais com Alto Volume de Atendimentos , Idoso de 80 Anos ou mais , Medição de Risco
2.
Europace ; 26(7)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-39031021

RESUMO

AIMS: Ventricular tachycardia (VT) non-inducibility in response to programmed ventricular stimulation (PVS) is a widely used procedural endpoint for VT ablation despite inconclusive evidence with respect to clinical outcomes in high-risk patients. The aim is to determine the utility of acute post-ablation VT inducibility as a predictor of VT recurrence, mortality, or mortality equivalent in high-risk patients. METHODS AND RESULTS: We conducted a retrospective analysis of high-risk patients (defined as PAINESD > 17) who underwent scar-related VT ablation at our institution between July 2010 and July 2022. Patients' response to PVS (post-procedure) was categorized into three groups: Group A, no clinical VT or VT with cycle length > 240 ms inducible; Group B, only non-clinical VT with cycle length > 240 ms induced; and Group C, all other outcomes (including cases where no PVS was performed). The combined primary endpoint included death, durable left ventricular assist device placement, and cardiac transplant (Cox analysis). Ventricular tachycardia recurrence was considered a secondary endpoint (competing risk analysis). Of the 1677 VT ablation cases, 123 cases met the inclusion criteria for analysis. During a 19-month median follow-up time (interquartile range 4-43 months), 82 (66.7%) patients experienced the composite primary endpoint. There was no difference between Groups A and C with respect to the primary [hazard ratio (HR) = 1.21 (0.94-1.57), P = 0.145] or secondary [HR = 1.18 (0.91-1.54), P = 0.210] outcomes. These findings persisted after multivariate adjustments. The size of Group B (n = 13) did not permit meaningful statistical analysis. CONCLUSION: The results of post-ablation PVS do not significantly correlate with long-term outcomes in high-risk (PAINESD > 17) VT ablation patients.


Assuntos
Ablação por Cateter , Cicatriz , Recidiva , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/diagnóstico , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Cicatriz/fisiopatologia , Cicatriz/etiologia , Idoso , Medição de Risco , Resultado do Tratamento , Fatores de Risco
3.
Europace ; 26(7)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-39082723

RESUMO

AIMS: Ventricular tachycardia (VT) non-inducibility in response to programmed ventricular stimulation (PVS) is a widely used procedural endpoint for VT ablation despite inconclusive evidence with respect to clinical outcomes in high-risk patients. The aim is to determine the utility of acute post-ablation VT inducibility as a predictor of VT recurrence, mortality, or mortality equivalent in high-risk patients. METHODS AND RESULTS: We conducted a retrospective analysis of high-risk patients (defined as PAINESD > 17) who underwent scar-related VT ablation at our institution between July 2010 and July 2022. Patients' response to PVS (post-procedure) was categorized into three groups: Group A, no clinical VT or VT with cycle length > 240 ms inducible; Group B, only non-clinical VT with cycle length > 240 ms induced; and Group C, all other outcomes (including cases where no PVS was performed). The combined primary endpoint included death, durable left ventricular assist device placement, and cardiac transplant (Cox analysis). Ventricular tachycardia recurrence was considered a secondary endpoint (competing risk analysis). Of the 1677 VT ablation cases, 123 cases met the inclusion criteria for analysis. During a 19-month median follow-up time (interquartile range 4-43 months), 82 (66.7%) patients experienced the composite primary endpoint. There was no difference between Groups A and C with respect to the primary [hazard ratio (HR) = 1.21 (0.94-1.57), P = 0.145] or secondary [HR = 1.18 (0.91-1.54), P = 0.210] outcomes. These findings persisted after multivariate adjustments. The size of Group B (n = 13) did not permit meaningful statistical analysis. CONCLUSION: The results of post-ablation PVS do not significantly correlate with long-term outcomes in high-risk (PAINESD > 17) VT ablation patients.


Assuntos
Ablação por Cateter , Cicatriz , Recidiva , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/diagnóstico , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Cicatriz/fisiopatologia , Cicatriz/etiologia , Idoso , Medição de Risco , Resultado do Tratamento , Fatores de Risco
4.
J Cardiovasc Electrophysiol ; 34(2): 465-467, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36640434

RESUMO

We aimed to evaluate trends and disparities in mortality from ventricular tachycardia in patients with underlying cardiovascular disease. We performed cross-sectional analyses using publicly available data from the Center for Disease Control and Prevention Wide-Ranging Online Data for Epidemiologic Research database. We identified a total of 7025 deaths from ventricular tachycardia between the years 2007 and 2020. Overall, age-adjusted mortality rates increased from 0.22 in 1999 to 0.32 in 2020 (p < .05). Black female and male adults had higher age-adjusted mortality rates compared to White female and male adults, respectively (p < .05). Disproportionate age-adjusted mortality rates among male populations and Southern residents were also observed. This study demonstrated an increase in deaths related to ventricular tachycardia since 2007. Significant differences in mortality exist across racial, gender, and geographic subgroups.


Assuntos
Disparidades nos Níveis de Saúde , Taquicardia Ventricular , Adulto , Feminino , Humanos , Masculino , Negro ou Afro-Americano , Estudos Transversais , Grupos Raciais , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidade , Estados Unidos/epidemiologia , Brancos
5.
J Cardiovasc Electrophysiol ; 34(8): 1648-1657, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37493505

RESUMO

INTRODUCTION: Obesity is a well-known risk factor for atrial fibrillation (AF). We aim to evaluate the effect of baseline obesity on procedural complications, AF recurrence, and symptoms following catheter ablation (CA). METHODS: All consecutive patients undergoing AF ablation (2013-2021) at our center were enrolled in a prospective registry. The study included all consecutive patients with available data on body mass index (BMI). Primary endpoint was AF recurrence based on electrocardiographic documentation. Patients were categorized into five groups according to their baseline BMI. Patients survey at baseline and at follow-up were used to calculate AF symptom severity score (AFSS) as well as AF burden (mean of AF duration score and AF frequency score; scale 0: no AF to 10: continuous and 9 frequencies/durations in between). Patients were scheduled for follow-up visits with 12-lead electrocardiogram at 3, 6, and 12 months after ablation, and every 6 months thereafter. RESULTS: A total of 5841 patients were included (17% normal weight, 34% overweight, 27% Class I, 13% Class II, and 9% Class III obesity). Major procedural complications were low (1.5%) among all BMI subgroups. At 3 years AF recurrence was the highest in Class III obesity patients (48%) followed by Class II (43%), whereas Class I, normal, and overweight had similar results with lower recurrence (35%). In multivariable analyses, Class III obesity (BMI ≥ 40) was independently associated with increased risk for AF recurrence (hazard ratio, 1.30; confidence interval, 1.06-1.60; p = .01), whereas other groups had similar risk in comparison to normal weight. Baseline AFSS was lowest in normal weight, and highest in Obesity-III, median (interquartile range) 10 (5-16) versus 15 (10-21). In all groups, CA resulted in a significant improvement in their AFSS with a similar magnitude among the groups. At follow-up, AF burden was minimal and did not differ significantly between the groups. CONCLUSION: AF ablation is safe with a low complication rate across all BMI groups. Morbid obesity (BMI ≥ 40) was significantly associated with reduced AF ablation success. However, ablation resulted in improvement in QoL including reduction of the AFSS, and AF burden regardless of BMI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Qualidade de Vida , Sobrepeso/diagnóstico , Recidiva , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Obesidade/complicações , Obesidade/diagnóstico , Resultado do Tratamento
6.
Europace ; 25(12)2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-38000893

RESUMO

AIMS: Transvenous lead extraction (TLE) of implantable cardioverter-defibrillator (ICD) leads is considered challenging. The structure of each ICD leads is variable between manufacturer and model families. The net impact of lead family on the safety and effectiveness of TLE is poorly characterized. We assessed the safety and efficacy of ICD TLE and the impact of manufacturer ICD model family on the outcomes. METHODS AND RESULTS: The study cohort included all consecutive patients with ICD who underwent TLE between 2013 and 2022 and are enrolled in the Cleveland Clinic Prospective TLE Registry. A total of 885 ICD leads (median implant duration 8 years) in 810 patients were included. Complete ICD TLE success was achieved in 97.2% of the leads (n = 860) and in 98.0% of the patients (n = 794). Major complications occurred in 22 patients (2.7%). Complete procedural success rate varied by manufacturer and lead family; Medtronic 98.9%, Abbott 95.9%, Boston Scientific 95.0%, Biotronik 91.2%, P = 0.03, and Linox family leads had the lowest, 89.7% P = 0.02. Multivariable predictors of incomplete ICD lead removal included ICD lead age > 10 years and Linox family lead. Multivariable predictors of major complications included ICD lead age > 15 years and longer lead extraction time, and predictors of all-cause mortality within 30 days included lead extraction for infection, end-stage renal disease, and higher New York Heart Association functional class. CONCLUSION: Complete and safe ICD lead removal rate by TLE is extremely high but varied by manufacturer and lead family. Linox family lead and >10 years lead age were independent predictors of incomplete lead removal.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Criança , Adolescente , Desfibriladores Implantáveis/efeitos adversos , Estudos Prospectivos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Estudos Retrospectivos , Resultado do Tratamento
7.
Pacing Clin Electrophysiol ; 41(10): 1341-1344, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30132950

RESUMO

BACKGROUND: Subcutaneous shocking coils (SQC) have been used to lower defibrillation thresholds in certain patient populations. There are limited data regarding the extraction complexity of these leads. The goal of this study is to describe our SQC extraction experience and identify challenges that may be of importance with the increase in utilization and extraction of fully subcutaneous defibrillator systems. METHODS: We studied consecutive patients who underwent lead removal at our institution during which a Medtronic 6996SQ (Medtronic plc, Minneapolis, MN, USA) was removed RESULTS: Twenty-one patients (54.5 ± 14 years, 85.7% male) underwent procedures where at least one lead removed was a SQC. Mean ejection fraction was 27.7% and 11 patients had prior ventricular arrhythmia. Median SQC age was 177 days and the age of the oldest SQC removed was 3,041 days. Infection was the indication for removal in 14 patients. One removal was performed surgically and 20 were completed percutaneously. Three procedures required additional incisions beyond the device pocket and tie-down sleeve to complete the SQC lead removal due to dense adhesions. One removal procedure required the use of a laser sheath to relieve fibrosis. Complications in this group did not appear related to SQC removal. CONCLUSIONS: Drawing from our SQC removal experience, there may be a need for additional incisions and extra tools to complete removal of older subcutaneous implantable cardioverter defibrillator leads.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Eletrodos Implantados/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
8.
JACC Case Rep ; 29(4): 102185, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38379643

RESUMO

Hypervagotonic sinus node dysfunction (SND) is a form of SND with sinus bradycardia caused by enhanced vagal tone. Indirect proof of hypervagotonia as the mechanism can be inferred from resolution of bradycardia following atropine infusion. In symptomatic patients, pacemaker implantation is recommended. We describe cardioneuroablation as a treatment for hypervagotonic SND.

9.
JACC Clin Electrophysiol ; 10(2): 222-234, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37978965

RESUMO

BACKGROUND: The efficacy of pulsed field ablation (PFA) for redo procedures is unknown. OBJECTIVES: In this study, the authors aimed to evaluate the effectiveness of PFA when performing PFA over chronic RFA (redo environment). METHODS: This was a 3-step in vivo study. In step 1 (creation of redo environment), 6 swine underwent radiofrequency ablation (RFA) with a local impedance measuring catheter and a contact force-enabled catheter in 3 different sites: the right atrium (RA) (intercaval line with intentional gaps), the left atrium (LA) (pulmonary vein isolation [PVI] with intentional gaps and superficial posterior wall ablations), and the left ventricle (LV) (short RFA applications [chronic RFA]). In step 2 (re-ablation), following a survival period of ≈5 weeks, animals were retreated as follows: in the RA, a focal PFA catheter over the prior intercaval line; in the LA, PVI using a pentaspline PFA catheter; and in the LV, animals were randomized to focal PFA or RFA. In each arm, 2 types of lesions were performed: acute or acute over chronic. In step 3 (remapping and euthanization), following an additional 3 to 5 days, all animals were remapped and sacrificed. RESULTS: In the RA, re-ablation with PFA resulted in a complete intercaval block in all animals, expanding and homogenizing the disparate chronic RFA lesions from a width of 4 to 7 mm (chronic RFA) to a width of 16 to 28 mm (PFA over chronic RFA). In the LA, re-ablation with PFA resulted in complete PVI and transmural ablation of the PW. In the LV, the mean depth for acute RFA (post 2-5 days survival) was 7.6 ± 1.3 mm vs 3.9 ± 1.6 mm in the acute over chronic RFA lesions (P < 0.01). In contrast, the mean depth for acute PFA was 7.0 ± 1.6 mm, similar to when ablating with PFA over RFA (7.1 ± 1.3 mm; P = 0.94). CONCLUSIONS: PFA is highly efficient for ablation following prior RFA, which may be beneficial in patients presenting for redo procedures. In the ventricle, PFA resulted in lesions that are deeper than RFA when ablating over chronic superficial RFA lesions.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Humanos , Animais , Suínos , Átrios do Coração/cirurgia , Ventrículos do Coração/cirurgia , Catéteres , Impedância Elétrica
10.
Circ Arrhythm Electrophysiol ; : e012814, 2024 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-39051118

RESUMO

BACKGROUND: During pulsed field ablation (PFA), relationships between ablation parameters (contact force [CF], number of burst pulses, impedance decrease, and electrode temperature) and lesion size in beating hearts have not been well validated. METHODS: A 7F-catheter with a 3.5-mm ablation electrode and CF sensor (ThermoCool SmartTouch SF-Dual-Energy, Biosense Webster, Inc, Irwindale, CA) was connected to a PFA system (TRUPULSE2, Biosense Webster, Inc). In 11 closed-chest swine, biphasic PFA current was delivered between the ablation electrode and the skin patch at 219 sites in left ventricle and right ventricle using 12, 18, and 24 burst pulses with 4 different levels of CF: (1) low (n=57; CF, 4-15g; median, 10g); (2) moderate (n=60; CF, 16-30g; median, 22.5g); (3) high (n=68; CF, 32-65g; median, 40g); and (4) no electrode contact (n=34), 2 mm away from the endocardium. Swine were euthanized 2 hours after ablation, and lesion size was measured using triphenyl tetrazolium chloride staining. RESULTS: All PFA lesions with electrode-myocardium contact were well demarcated with triphenyl tetrazolium chloride staining, demonstrating (1) pale central zone (contraction band necrosis with minimal coagulation necrosis), (2) dark brown zone (contraction band necrosis with hemorrhage), and (3) hyperstained red zone by triphenyl tetrazolium chloride (unaffected normal myocardium with preserved mitochondrial activity, consistent with reversible zone). Lesion depth increased significantly with increasing CF and the number of PFA burst pulses. An exponential/logarithmic formula combined with CF and the number of PFA burst pulses correlated lesion depth with high accuracy: R=0.809, P<0.0001, ±1.0-mm accuracy in 128 of 163 (79%) lesions, and ±1.5-mm accuracy in 153 of 163 (94%) lesions. Impedance decrease and electrode temperature were poor predictors of lesion size. There were no detectable lesions resulting from ablation without electrode contact. CONCLUSIONS: Acute PFA ventricular lesions demonstrate irreversible and reversible lesion boundaries. Electrode-tissue contact is required for effective lesion formation. Lesion depth increases significantly with increasing CF and PFA burst pulses. A new exponential/logarithmic formula combined with CF and the number of PFA burst pulses correlates lesion depth with high accuracy.

11.
Circ Arrhythm Electrophysiol ; 17(1): e012026, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38152949

RESUMO

BACKGROUND: Effects of contact force (CF) on lesion formation during pulsed field ablation (PFA) have not been well validated. The purpose of this study was to determine the relationship between average CF and lesion size during PFA using a swine-beating heart model. METHODS: A 7F catheter with a 3.5-mm ablation electrode and CF sensor (TactiCath SE, Abbott) was connected to a PFA system (CENTAURI, Galvanize Therapeutics). In 5 closed-chest swine, biphasic PFA current was delivered between the ablation electrode and a skin patch at 40 separate sites in right ventricle (28 Amp) and 55 separate sites in left ventricle (35 Amp) with 4 different levels of CF: (1) low (CF range of 4-13 g; median, 9.5 g); (2) moderate (15-30 g; median, 21.5 g); (3) high (34-55 g; median, 40 g); and (4) no electrode contact, 2 mm away from the endocardium. Swine were sacrificed at 2 hours after ablation, and lesion size was measured using triphenyl tetrazolium chloride staining. In 1 additional swine, COX (cytochrome c oxidase) staining was performed to examine mitochondrial activity to delineate reversible and irreversible lesion boundaries. Histological examination was performed with hematoxylin and eosin and Masson trichrome staining. RESULTS: Ablation lesions were well demarcated with triphenyl tetrazolium chloride staining, showing (1) a dark central zone (contraction band necrosis and hemorrhage); (2) a pale zone (no mitochondrial activity and nuclear pyknosis, indicating apoptosis zone); and a hyperstained zone by triphenyl tetrazolium chloride and COX staining (unaffected normal myocardium with preserved mitochondrial activity, consistent with reversible zone). At constant PFA current intensity, lesion depth increased significantly with increasing CF. There were no detectable lesions resulting from ablation without electrode contact. CONCLUSIONS: Acute PFA ventricular lesions show irreversible and reversible lesion boundaries by triphenyl tetrazolium chloride staining. Electrode-tissue contact is required for effective lesion formation during PFA. At the same PFA dose, lesion depth increases significantly with increasing CF.


Assuntos
Ablação por Cateter , Ventrículos do Coração , Suínos , Animais , Ventrículos do Coração/cirurgia , Ventrículos do Coração/patologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Cloretos , Coração , Catéteres
12.
Circ Arrhythm Electrophysiol ; 17(6): e012723, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38690671

RESUMO

BACKGROUND: Conventional focal radiofrequency catheters may be modified to enable multiple energy modalities (radiofrequency or pulsed field [PF]) with the benefit of contact force (CF) feedback, providing greater flexibility in the treatment of arrhythmias. Information on the impact of CF on lesion formation in PF ablations remains limited. METHODS: An in vivo study was performed with 8 swine using an investigational dual-energy CF focal catheter with local impedance. Experiment I: To evaluate atrial lesion formation, contiguity, and width, a point-by-point approach was used to create an intercaval line. The distance between the points was prespecified at 4±1 mm. Half of the line was created with radiofrequency energy, whereas the other half utilized PF (single 2.0 kV application with a proprietary waveform). Experiment II: To evaluate single application lesion dimensions with a proprietary waveform, discrete ventricular lesions were performed with PFA (single 2.0 kV application) with targeted levels of CF: low, 5 to 15 g; medium, 20 to 30 g; and high, 35 to 45 g. Following 1 week of survival, animals underwent endocardial/epicardial remapping, and euthanasia to enable histopathologic examination. RESULTS: Experiment I: Both energy modalities resulted in a complete intercaval line of transmural ablation. PF resulted in significantly wider lines than radiofrequency: minimum width, 14.9±2.3 versus 5.0±1.6 mm; maximum width, 21.8±3.4 versus 7.3±2.1 mm, respectively; P<0.01 for each. Histology confirmed transmural lesions with both modalities. Experiment II: With PF, lesion depth, width, and volume were larger with higher degrees of CF (depth: r=0.82, P<0.001; width: r=0.26, P=0.052; and volume: r=0.55, P<0.001), with depth increasing at a faster rate than width. The mean depths were as follows: low (n=17), 4.3±1.0 mm; medium (n=26), 6.4±1.2 mm; and high (n=14), 9.1±1.4 mm. CONCLUSIONS: Using the same focal point CF-sensing catheter, a novel PF ablation waveform with a single application resulted in transmural atrial lesions that were significantly wider than radiofrequency. Lesion depth showed a significant positive correlation with CF with depths of 6.4 mm at moderate CF.


Assuntos
Cateteres Cardíacos , Ablação por Cateter , Desenho de Equipamento , Animais , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Suínos , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Modelos Animais , Sus scrofa , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia
13.
Artigo em Inglês | MEDLINE | ID: mdl-38878017

RESUMO

BACKGROUND: Comparative efficacy and safety data on radiofrequency ablation (RFA) versus pulsed field ablation (PFA) for common idiopathic left ventricular arrhythmia (LV-VAs) locations are lacking. OBJECTIVES: This study sough to compare RFA with PFA of common idiopathic LV-VAs locations. METHODS: Ten swine were randomized to PFA or RFA of LV interventricular septum, papillary muscle, LV summit via distal coronary sinus, and LV epicardium via subxiphoid approach. Ablations were delivered using an investigational dual-energy (RFA/PFA) contact force (CF) and local impedance-sensing catheter. After 1-week survival, animals were euthanized for lesion assessment. RESULTS: A total of 55 PFA (4 applications/site of 2.0 KV, target CF ≥10 g) and 36 RFA (CF ≥10 g, 25-50 W targeting ≥50 Ω local impedance drop, 60-second duration) were performed. LV interventricular septum: average PFA depth 7.8 mm vs RFA 7.9 mm (P = 0.78) and no adverse events. Papillary muscle: average PFA depth 8.1 mm vs RFA 4.5 mm (P < 0.01). Left ventricular summit: average PFA depth 5.6 mm vs RFA 2.7 mm (P < 0.01). Steam-pop and/or ventricular fibrillation in 4 of 12 RFA vs 0 of 12 PFA (P < 0.01), no ST-segment changes observed. Epicardium: average PFA depth 6.4 mm vs RFA 3.3 mm (P < 0.01). Transient ST-segment elevations/depressions occurred in 4 of 5 swine in the PFA arm vs 0 of 5 in the RFA arm (P < 0.01). Angiography acutely and at 7 days showed normal coronaries in all cases. CONCLUSIONS: In this swine study, compared with RFA, PFA of common idiopathic LV-VAs locations produced deeper lesions with fewer steam pops. However, PFA was associated with higher rates of transient ST-segment elevations and depressions with direct epicardium ablation.

14.
J Am Heart Assoc ; 13(3): e032760, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38293932

RESUMO

BACKGROUND: Data regarding permanent pacemaker (PPM) implantation following tricuspid valve surgery (TVS) are limited. We sought to evaluate its incidence, risk factors, and outcomes. METHODS AND RESULTS: Medicare beneficiaries who underwent TVS from 2013 to 2020 were identified. Patients who underwent TVS for endocarditis were excluded. The primary exposure of interest was new PPM after TVS. Outcomes included all-cause mortality and readmission with endocarditis or heart failure on follow-up. Among the 13 294 patients who underwent TVS, 2518 (18.9%) required PPM placement. Risk factors included female sex (relative risk [RR], 1.26 [95% CI, 1.17-1.36], P<0.0001), prior sternotomy (RR, 1.12 [95% CI, 1.02-1.23], P=0.02), preoperative second-degree heart block (RR, 2.20 [95% CI, 1.81-2.69], P<0.0001), right bundle-branch block (RR, 1.21 [95% CI, 1.03-1.41], P=0.019), bifascicular block (RR, 1.43 [95% CI, 1.06-1.93], P=0.02), and prior malignancy (RR, 1.23 [95% CI, 1.01-1.49], P=0.04). Tricuspid valve (TV) replacement was associated with a significantly higher risk of PPM implantation when compared with TV repair (RR, 3.20 [95% CI, 2.16-4.75], P<0.0001). After a median follow-up of 3.1 years, mortality was not different in patients who received PPM compared with patients who did not (hazard ratio [HR], 1.02 [95% CI, 0.93-1.12], P=0.7). PPM placement was not associated with a higher risk of endocarditis but was associated with a higher risk of heart failure readmission (HR, 1.28 [95% CI, 1.14-1.43], P<0.001). CONCLUSIONS: PPM implantation frequently occurs after TVS, notably in female patients and patients undergoing TV replacement. Although mortality is not increased, it is associated with higher rates of heart failure rehospitalization.


Assuntos
Estenose da Valva Aórtica , Endocardite , Insuficiência Cardíaca , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Estados Unidos/epidemiologia , Estenose da Valva Aórtica/cirurgia , Estimulação Cardíaca Artificial/efeitos adversos , Incidência , Valva Tricúspide/cirurgia , Resultado do Tratamento , Medicare , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Bloqueio de Ramo/terapia , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/complicações , Endocardite/cirurgia , Valva Aórtica/cirurgia , Estudos Retrospectivos
15.
Heart Rhythm ; 2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39084586

RESUMO

BACKGROUND: Risk for ventricular arrhythmias (VA) following cardiac resynchronization therapy (CRT) has been associated with ischemic disease/scar, sex, and possibly left ventricular mass (LVM). OBJECTIVE: To evaluate sex differences and baseline/post-implant change [Δ] of LVM on VA risk after CRT implant among patients with non-ischemic cardiomyopathy (NICM) and left bundle branch block. METHODS: Among patients meeting the criteria, baseline and follow-up echocardiographic images were obtained for LVM assessment. VA events were reported from device diagnostics and therapies. VA risk was stratified by ROC (Youden-index cut-point) for baseline LVM and ΔLVM, and baseline patient characteristics using a multivariable Cox regression model. RESULTS: 118 patients (71[60.2%] female, age 60.5 ±11.3 years, LVEF 19.2 ±7.0%, QRS 165.6 ±20 ms, LVM 313.9 ±108.8 g) were enrolled and followed for median 90 (IQR 44-158) months. Thirty-five (29.6%) patients received appropriate shocks or anti-tachycardia pacing at a median of 73.5 (IQR 25-130) months post-implant. Males had a higher VA incidence (male 18/47 [38.3%] vs. female 17/71 [23.9%], P=0.02). Baseline LVM >308.9g separated patients with higher VA risk (P=0.001). Less than a 20% decrease in LVM increased VA risk (P<0.001). Baseline LVM was the only baseline characteristic predicting VA events in the Cox regression model (Hazard ratio 1.01 [95%CI, 1.001-1.009], Log-rank P=0.003). Sex differences in VA risk were eliminated by the baseline LVM parameters. CONCLUSION: VA risk after CRT in NICM was associated with baseline LV >308.9g and a decrease in LVM ≤ 20%, without sex differences.

16.
Heart Rhythm ; 20(6): 872-878, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36933853

RESUMO

BACKGROUND: Reports of coronary sinus (CS) lead removal include small studies with short implant durations. Procedural outcomes for mature CS leads removed with long duration implantation are unavailable. OBJECTIVE: The purpose of this study was to examine the safety, efficacy, and clinical predictors of incomplete CS lead removal by transvenous lead extraction (TLE) in a large long implant duration cardiac resynchronization therapy patient cohort. METHODS: Consecutive patients with cardiac resynchronization therapy devices in the Cleveland Clinic Prospective TLE Registry who had TLE between 2013 and 2022 were included in the analysis. RESULTS: CS leads (N = 231; implant duration 6.1 ± 4.0 years) removed from 226 patients were included, using powered sheaths for 137 leads (59.3%). Complete CS lead extraction success was achieved in 95.2% of leads (n = 220) and in 95.6% of patients (n = 216). Major complications occurred in 5 patients (2.2%). Patients who had the CS lead extracted first had significantly higher incomplete removal rates than when the other leads were first removed. Multivariable analysis showed that older CS lead age (odds ratio 1.35; 95% confidence interval 1.01-1.82; P = .03) and removal of the first CS lead (odds ratio 7.48; 95% confidence interval 1.02-54.95; P = .045) were independent predictors of incomplete CS lead removal. CONCLUSION: The complete and safe lead removal rate of long implant duration CS leads by TLE was 95%. However, CS lead age and the order in which leads were extracted were the independent predictors of incomplete CS lead removal. Therefore, before the CS lead is extracted, physicians should first extract the leads from the other chambers and use powered sheaths.


Assuntos
Terapia de Ressincronização Cardíaca , Seio Coronário , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Estudos Prospectivos , Seio Coronário/cirurgia , Remoção de Dispositivo/efeitos adversos , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos
17.
Struct Heart ; 7(5): 100188, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37745676

RESUMO

•Cardiac computed tomography (CCT) can be used as a useful complementary tool in preprocedural planning of left atrial appendage closure.•CCT planning includes assessing exclusion criteria, device sizing, sheath selection, anticipating challenging anatomies, and transseptal puncture planning.•Procedural 3D intracardiac echocardiography (3D-ICE) is increasingly being used instead of transesophageal echocardiography. In this setting, preprocedural CCT is useful to compensate for 3D ICE's reduced resolution.

18.
Heliyon ; 9(11): e22178, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38045193

RESUMO

Background: Atrial fibrillation (AF) catheter ablation has become an increasingly effective and safe strategy for the management of AF. With increased safety of catheter ablation, same-day discharge (SDD) is a potential way to minimize health care resource utilization and improve patient experience. Objective: To evaluate the safety and patient satisfaction of SDD after contemporary AF ablation. Methods: Consecutive patient undergoing AF ablation at our institution between 1/2020 and 10/2021 were enrolled in registry for clinical, quality, procedural and outcomes data. Patients were considered for SDD per physician discretion and patients' preference based upon clinical evaluation. Adjudicated ninety-day major complications, thirty-day adverse events, and thirty-day re-admissions were collected in a prospective registry for all patients. Results: A total of 2142 consecutive patients underwent elective AF ablation during the study period. After excluding cases with missing data, 1830 patients were included in the analysis. Of those, 350 (19 %) patients were discharged the same day (SDD group) and 1480 (81 %) stayed overnight. Patients in the SDD group compared to overnight stay group were younger, more likely to be male, White patients, lower CHA2DS2-VASc score and to be on lower rates of warfarin as an anticoagulation strategy. After propensity score matching, SDD was associated with lower rate of major complications and higher patient satisfaction. The majority of life-treating complications occurred interprocedurally or within 6 h of procedure termination. Conclusion: The present study demonstrated that SDD after contemporary AF ablation is feasible, safe and associated with higher patient satisfaction using a proposed SDD pathway and criteria.

19.
JACC Clin Electrophysiol ; 9(9): 1890-1899, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37542488

RESUMO

BACKGROUND: Monomorphic ventricular tachycardia (VT) electrical storm (ES) in patients with coronary artery disease is dependent on scarred myocardium. The role of routine ischemic or coronary evaluations before ablation in patients presenting with monomorphic VT storm, without acute coronary syndrome (ACS), remains unknown. OBJECTIVES: This study sought to assess the impact of ischemic or coronary evaluations on procedural outcomes and post-ablation mortality in monomorphic VT storm patients. METHODS: All patients undergoing VT ablation at the Cleveland Clinic from 2014 to 2020 after presenting with monomorphic VT storm were enrolled in a prospectively maintained registry. The associations among ischemic or coronary evaluations and short-term procedural efficacy, acute outcomes, and mortality during follow-up were assessed. RESULTS: A total of 97 consecutive patients with monomorphic VT storm in the absence of ACS underwent VT ablations. This cohort was characterized by severe LV systolic dysfunction (mean left ventricular ejection fraction 30.3%, 67% with known ischemic cardiomyopathy) with moderately severe heart failure (median NYHA functional class II); 45% of patients underwent ischemic or coronary evaluations via coronary angiography (10%), noninvasive myocardial perfusion (26%), or both (9%). The yield of these evaluations was low: No acute coronary occlusions were identified. There was no association between ischemic evaluation and acute ablation outcomes or mortality during follow-up. Similarly, in a secondary analysis, the yield of ischemic or coronary evaluations in patients with monomorphic VT storm and known coronary disease (regardless of ablation status) was found to be low. CONCLUSIONS: Ischemic evaluations in patients with monomorphic VT storm without ACS may not improve procedural outcomes or mortality after ablation.


Assuntos
Síndrome Coronariana Aguda , Ablação por Cateter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Resultado do Tratamento , Volume Sistólico , Função Ventricular Esquerda , Isquemia Miocárdica/complicações , Isquemia Miocárdica/cirurgia , Síndrome Coronariana Aguda/complicações , Ablação por Cateter/efeitos adversos
20.
Heart Rhythm O2 ; 3(3): 248-251, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35734298

RESUMO

Background: Little is known about the incidence and risk factors for the development of acute pericarditis after ablation for atrial fibrillation (AF). Objective: The purpose of this retrospective cohort study was to describe the occurrence of and associations with suspected acute pericarditis after AF ablation. Methods: All patients undergoing AF ablation in our center were enrolled in a prospectively maintained registry. Suspected acute pericarditis was defined as pericardial chest pain treated with disease specific anti-inflammatories within 3 months of AF ablation. Results: Among 2215 patients with AF ablations between January 1, 2018, and December 31, 2019, 226 (10.2%) had suspected acute pericarditis. Treatments included colchicine in 149 patients (65.9%), prednisone in 66 (29.2%), and high-dose ibuprofen in 43 (19.0%). Multiple anti-inflammatory therapies were used in 57 patients (25%). At baseline, a lower CHADS2VASc score and a higher body mass index were associated with pericarditis, whereas older patients were less likely to have pericarditis. With multivariable adjustment, age was associated with suspected acute pericarditis (odds ratio 0.95; 95% confidence interval 0.94-0.97; P <.0001). Among patients with suspected pericarditis, postprocedure pericardial effusion was present in 9.3% and pericarditis electrocardiographic changes in 19.5%. Conclusion: Suspected acute pericarditis is common after AF ablation and is associated with a younger age. Systematic assessments for acute pericarditis after AF ablation should be considered.