Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 145
Filtrar
1.
Circulation ; 143(2): 104-116, 2021 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-32975133

RESUMO

BACKGROUND: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining midterm outcomes after mitral ViV and ViR. METHODS: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry. Cases were performed between March 2006 and March 2020. Clinical endpoints are reported according to the Mitral Valve Academic Research Consortium (MVARC) definitions. Significant residual mitral stenosis (MS) was defined as mean gradient ≥10 mm Hg and significant residual mitral regurgitation (MR) as ≥ moderate. RESULTS: A total of 1079 patients (857 ViV, 222 ViR; mean age 73.5±12.5 years; 40.8% male) from 90 centers were included. Median STS-PROM score 8.6%; median clinical follow-up 492 days (interquartile range, 76-996); median echocardiographic follow-up for patients that survived 1 year was 772.5 days (interquartile range, 510-1211.75). Four-year Kaplan-Meier survival rate was 62.5% in ViV versus 49.5% for ViR (P<0.001). Mean gradient across the mitral valve postprocedure was 5.7±2.8 mm Hg (≥5 mm Hg; 61.4% of patients). Significant residual MS occurred in 8.2% of the ViV and 12.0% of the ViR patients (P=0.09). Significant residual MR was more common in ViR patients (16.6% versus 3.1%; P<0.001) and was associated with lower survival at 4 years (35.1% versus 61.6%; P=0.02). The rates of Mitral Valve Academic Research Consortium-defined device success were low for both procedures (39.4% total; 32.0% ViR versus 41.3% ViV; P=0.01), mostly related to having postprocedural mean gradient ≥5 mm Hg. Correlates for residual MS were smaller true internal diameter, younger age, and larger body mass index. The only correlate for residual MR was ViR. Significant residual MS (subhazard ratio, 4.67; 95% CI, 1.74-12.56; P=0.002) and significant residual MR (subhazard ratio, 7.88; 95% CI, 2.88-21.53; P<0.001) were both independently associated with repeat mitral valve replacement. CONCLUSIONS: Significant residual MS and/or MR were not infrequent after mitral ViV and ViR procedures and were both associated with a need for repeat valve replacement. Strategies to improve postprocedural hemodynamics in mitral ViV and ViR should be further explored.


Assuntos
Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas/normas , Valva Mitral/cirurgia , Sistema de Registros , Reoperação/normas , Substituição da Valva Aórtica Transcateter/normas , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Próteses Valvulares Cardíacas/tendências , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/tendências , Humanos , Internacionalidade , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Reoperação/tendências , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/tendências
2.
Eur Heart J ; 41(29): 2731-2742, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32592401

RESUMO

AIMS: Due to bioprosthetic valve degeneration, aortic valve-in-valve (ViV) procedures are increasingly performed. There are no data on long-term outcomes after aortic ViV. Our aim was to perform a large-scale assessment of long-term survival and reintervention after aortic ViV. METHODS AND RESULTS: A total of 1006 aortic ViV procedures performed more than 5 years ago [mean age 77.7 ± 9.7 years; 58.8% male; median STS-PROM score 7.3% (4.2-12.0)] were included in the analysis. Patients were treated with Medtronic self-expandable valves (CoreValve/Evolut, Medtronic Inc., Minneapolis, MN, USA) (n = 523, 52.0%), Edwards balloon-expandable valves (EBEV, SAPIEN/SAPIEN XT/SAPIEN 3, Edwards Lifesciences, Irvine, CA, USA) (n = 435, 43.2%), and other devices (n = 48, 4.8%). Survival was lower at 8 years in patients with small-failed bioprostheses [internal diameter (ID) ≤ 20 mm] compared with those with large-failed bioprostheses (ID > 20 mm) (33.2% vs. 40.5%, P = 0.01). Independent correlates for mortality included smaller-failed bioprosthetic valves [hazard ratio (HR) 1.07 (95% confidence interval (CI) 1.02-1.13)], age [HR 1.21 (95% CI 1.01-1.45)], and non-transfemoral access [HR 1.43 (95% CI 1.11-1.84)]. There were 40 reinterventions after ViV. Independent correlates for all-cause reintervention included pre-existing severe prosthesis-patient mismatch [subhazard ratio (SHR) 4.34 (95% CI 1.31-14.39)], device malposition [SHR 3.75 (95% CI 1.36-10.35)], EBEV [SHR 3.34 (95% CI 1.26-8.85)], and age [SHR 0.59 (95% CI 0.44-0.78)]. CONCLUSIONS: The size of the original failed valve may influence long-term mortality, and the type of the transcatheter valve may influence the need for reintervention after aortic ViV.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento
3.
Monaldi Arch Chest Dis ; 90(1)2020 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-32162894

RESUMO

Left ventricular pseudoaneurysms (LVP) are rare but may arise after myocardial infarction, trauma or cardiac surgery, tending to expand and rupture over the time. We show the case of a 75-year-old patient with a recurrent giant ventricular pseudoaneurysm, who presented to the emergency department with sustained ventricular tachycardia. Pseudoaneurysmatic lesion was investigated through echocardiography, angiography and Cardiac Computed Tomography, in order to evaluate the size and spatial orientation of the pseudoaneurysm and to set a tailored treatment. At emergency department, sustained ventricular tachycardia may be the first and unique clinical presentation of ventricular pseudoaneurysm late recurrence, whose management requires a multimodality imaging approach to guide surgical correction.


Assuntos
Falso Aneurisma , Ventrículos do Coração , Taquicardia Ventricular/etiologia , Idoso , Falso Aneurisma/complicações , Falso Aneurisma/diagnóstico por imagem , Angiografia , Procedimentos Cirúrgicos Cardíacos , Ecocardiografia , Aneurisma Cardíaco , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Recidiva , Tomografia Computadorizada por Raios X
4.
Catheter Cardiovasc Interv ; 94(5): 746-752, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30821116

RESUMO

OBJECTIVES: The aim of this study was to explore the time course of survival advantage of TAVR over SAVR as function of the patients' risk and sex. BACKGROUND: Women have been reported to have better survival than men undergoing transcatheter aortic valve replacement (TAVR). However, scant data on the sex-based survival benefit of TAVR over surgical aortic valve replacement (SAVR) are available. METHODS: A systematic review of studies reporting clinical outcomes of men and women undergoing TAVR or SAVR was performed. Studies were divided into two groups according to average patient's risk score and the interplay of surgical risk and sex on outcomes were analyzed. RESULTS: Eight studies involving 6,596 women and 7,204 men patients were extracted. Unlike mens, women patients had survival advantage from TAVR over SAVR that became substantial at 1 year from index procedure and persisted at 2-year of follow-up. Moreover, this sex-based TAVR survival advantage was mainly observed in higher surgical risk patients. Men showed a significantly lower rate of residual paravalvular leak after SAVR. CONCLUSIONS: Women patients had a selective mortality benefit from TAVR compared to SAVR. This sex-based TAVR benefit was mainly observed in high surgical risk patients beyond 1 year from procedure.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Medição de Risco , Fatores de Risco , Fatores Sexuais , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
5.
Eur Heart J ; 39(8): 687-695, 2018 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-29020413

RESUMO

Aims: There are limited data on coronary obstruction following transcatheter valve-in-valve (ViV) implantation inside failed aortic bioprostheses. The objectives of this study were to determine the incidence, predictors, and clinical outcomes of coronary obstruction in transcatheter ViV procedures. Methods and results: A total of 1612 aortic procedures from the Valve-in-Valve International Data (VIVID) Registry were evaluated. Data were subject to centralized blinded corelab computed tomography (CT) analysis in a subset of patients. The virtual transcatheter valve to coronary ostium distance (VTC) was determined. A total of 37 patients (2.3%) had clinically evident coronary obstruction. Baseline clinical characteristics in the coronary obstruction patients were similar to controls. Coronary obstruction was more common in stented bioprostheses with externally mounted leaflets or stentless bioprostheses than in stented with internally mounted leaflets bioprostheses (6.1% vs. 3.7% vs. 0.8%, respectively; P < 0.001). CT measurements were obtained in 20 (54%) and 90 (5.4%) of patients with and without coronary obstruction, respectively. VTC distance was shorter in coronary obstruction patients in relation to controls (3.24 ± 2.22 vs. 6.30 ± 2.34, respectively; P < 0.001). Using multivariable analysis, the use of a stentless or stented bioprosthesis with externally mounted leaflets [odds ratio (OR): 7.67; 95% confidence interval (CI): 3.14-18.7; P < 0.001] associated with coronary obstruction for the global population. In a second model with CT data, a shorter VTC distance predicted this complication (OR: 0.22 per 1 mm increase; 95% CI: 0.09-0.51; P < 0.001), with an optimal cut-off level of 4 mm (area under the curve: 0.943; P < 0.001). Coronary obstruction was associated with a high 30-day mortality (52.9% vs. 3.9% in the controls, respectively; P < 0.001). Conclusion: Coronary obstruction following aortic ViV procedures is a life-threatening complication that occurred more frequently in patients with prior stentless or stented bioprostheses with externally mounted leaflets and in those with a short VTC.


Assuntos
Oclusão Coronária/epidemiologia , Tomografia Computadorizada Multidetectores/métodos , Falha de Prótese/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/etiologia , Feminino , Próteses Valvulares Cardíacas , Humanos , Incidência , Masculino , Análise Multivariada , Sistema de Registros , Fatores de Risco
6.
Catheter Cardiovasc Interv ; 92(3): E159-E167, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-30019825

RESUMO

BACKGROUND: Previous implantation of a permanent pacemaker (PPM) is common among patients undergoing transcatheter aortic valve implantation (TAVI). Moreover, onset of conduction disturbances needing new PPM implantation after TAVI is frequent. The interplay of pre-existing and new-PPM on mortality after TAVI remains controversial. METHODS: We performed a systematic review and study-level meta-analysis on the influence of PPM on mortality after TAVI. Patients were divided into 3 groups: pre-existing PPM, new-PPM (implantation within 30 days after TAVI) and no-PPM (without PPM up to 30 days after TAVI). Outcomes were compared using pairwise and network meta-analysis. RESULTS: A total of 28 studies including 40,016 subjects were eligible. Patients of the no-PPM group had a lower mortality outcome compared to the rest of the study population (relative risk [RR] 0.76, 95% confidence interval [CI] 0.68-0.85, P < 0.0001) at median follow up of 16.3 months. In particular, patients with a pre-existing PPM (RR 1.43, 95% CI 1.26-1.62, P < 0.0001), but not those with a newly implanted PPM (RR 1.08, 95% CI 0.99-1.18, P = 0.10), had a significantly higher mortality compared to patients of the no-PPM group. Moreover, meta-regression analysis showed that the transapical approach rate had a detrimental interaction with pre-existing PPM on mortality (P = 0.03). CONCLUSION: Compared to patients without PPM, those with a pre-existing PPM before TAVI had higher mortality, in particular if treated by the transapical approach. New-PPM implantation did not have a negative relation on mid-term outcome.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial/mortalidade , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Estimulação Cardíaca Artificial/efeitos adversos , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento
7.
Scand J Clin Lab Invest ; 78(4): 281-286, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29575927

RESUMO

Dual antiplatelet therapy is recommended in patients undergoing primary percutaneous coronary intervention (p-PCI) for ST-segment elevation myocardial infarction (STEMI). Pre-analytical variables may influence platelet function analysis results. Our aim was to evaluate the on-treatment platelet reactivity in peripheral artery vs coronary blood in patients with STEMI. We enrolled one hundred and nine patients who consecutively underwent p-PCI at Cardiology Unit of Padua University Hospital between June 2014 and June 2015. Before the procedure, all patients received intravenous aspirin 250 mg and either of the thienopyridines; clopidogrel 600 mg, prasugrel 60 mg or ticagrelor 180 mg. ASPI-test and ADP-test using multiple electrode aggregometry (MEA) were performed in samples collected from both a peripheral artery and the culprit coronary artery. 'Low responders' were patients with an ASPI-test or ADP-test value greater than or equal to a pre-established normal range. No significant differences were observed in ASPI-test values between peripheral (19 (median) [3-49 (10-90 percentiles)] U) vs coronary (12 [1-40] U, p = .06) blood and in ADP-test (40 [14-82] U vs 33 [7-79] U, p =.68) blood. In peripheral blood, fifteen (14%) patients were 'low aspirin' and forty-one (38%) 'low thienopyridines' responders. The prevalence of 'low clopidogrel' responders was higher (45%) than prasugrel (36%) and ticagrelor (33%). Similar results were observed in coronary blood. In patients undergoing p-PCI for STEMI, MEA platelet function observed in coronary arteries was consistent with peripheral artery blood's independently of the antiplatelet drug used. The clinical significance of peripheral and coronary on-aspirin/thienopyridines platelet reactivity needs further clarification.


Assuntos
Plaquetas/patologia , Vasos Coronários/patologia , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/sangue , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Difosfato de Adenosina/farmacologia , Ácido Araquidônico/farmacologia , Aspirina/uso terapêutico , Demografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Agregação Plaquetária/efeitos dos fármacos , Inibidores da Agregação Plaquetária/uso terapêutico , Piridinas/farmacologia , Piridinas/uso terapêutico , Infarto do Miocárdio com Supradesnível do Segmento ST/tratamento farmacológico
8.
Echocardiography ; 34(2): 267-278, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28052455

RESUMO

The use of transcatheter aortic valve replacement (TAVR) for high-risk patients with aortic stenosis has rapidly increased during the past years. Accordingly, more and more patients are referred for a follow-up echocardiographic study after TAVR. However, the echocardiographic evaluation of patients who underwent TAVR places specific demands on echocardiographers. Furthermore, TAVR may be associated with new types of complications, which are frequently unrecognized or underestimated due to lack of familiarity with the normal and pathological appearance of TAVR. Therefore, this review summarizes the echocardiographic parameters describing the structural and functional status of bioprostheses used in TAVR, procedures taking into account their peculiar hemodynamics. We also describe the strengths and the limitations of echocardiography and of other imaging modalities in detecting long-term complications of TAVR (eg, infective endocarditis, thrombosis). The aim of this review was to serve as a guide for a structured echocardiographic follow-up of TAVR patients, as well as for the echocardiographic diagnosis of the procedure-associated complications.


Assuntos
Ecocardiografia/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Medição de Risco , Taxa de Sobrevida , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 87(2): 332-8, 2016 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-26010724

RESUMO

OBJECTIVES: To compare the outcomes of trans-subclavian (TS) and transapical (TA) access for transcatheter aortic valve implantation (TAVI). BACKGROUND: A considerable proportion of patients undergoing TAVI are not eligible for transfemoral approach. To date, there are few data to guide the choice between alternative vascular access routes. METHODS: Among 874 consecutive patients who underwent TAVI, 202 procedures were performed through TA (n = 142, 70.3%) or TS (n = 60, 29.7%) access. Medtronic Corevalve (CV, Medtronic, Minneapolis, MN) was implanted in 17.3% of the patients, the Edwards-Sapien (ES, Edwards Lifesciences Inc., Irvine, CA) in 81.2% and other prostheses in 0.1%. In-hospital and long-term outcome were assessed using the Valve Academic Research Consortium (VARC)-2 definitions. RESULTS: Mean age was 82 ± 6 years, STS score 9.3 ± 7.9%. The 2 groups showed a relevant imbalance in baseline characteristics. In hospital mortality was 6.4% (1.7% TS vs. 8.4% TA, P = 0.06), stroke 2.0%, acute myocardial infarction 1.0%, acute kidney injury 39.4%, sepsis 4.0% with no significant differences between groups, while bleeding was more frequent in TA patients (53.5% vs. 11.7% TS, P < 0.001). One- and 2-year survival was 85.2% and 73.2% in TS patients, and 83.9% and 74.9% in TA patients (P = ns for both). Access site was not an independent predictor of mortality at multivariable analysis. CONCLUSION: Transapical compared with trans-subclavian access for TAVI was associated with a nonsignificant trend to increased periprocedural events. However, 1- and 2-year survival appears similar.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica , Cateterismo Cardíaco/métodos , Cateterismo Periférico/métodos , Implante de Prótese de Valva Cardíaca/métodos , Artéria Subclávia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Cateterismo Periférico/efeitos adversos , Distribuição de Qui-Quadrado , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Itália , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Modelos de Riscos Proporcionais , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
10.
Circulation ; 127(12): 1300-7, 2013 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-23443735

RESUMO

BACKGROUND: Conduction disturbances are relatively common after transcatheter aortic valve implantation. Previous data demonstrated an adverse impact of persistent left bundle-branch block (LBBB) after surgical aortic valve replacement. It is unclear whether new-onset LBBB may also impact the prognosis of patients after transcatheter aortic valve implantation. METHODS AND RESULTS: Among 1060 patients treated with a CoreValve Revalving System transcatheter aortic valve implantation between October 2007 and April 2011 in high-volume centers in Italy, we analyzed those without LBBB or pacemaker at admission (879 patients [82.9%]). We further excluded those who underwent permanent pacemaker implantation within 48 hours after the procedure (61 patients [7%]), for a final study population of 818 patients. Among them, 224 patients (group A; 27.4%) developed a persistent LBBB and the remaining 594 (group B; 72.6%) did not. Clinical characteristics were similar between groups. A low implantation was significantly more frequent in group A (15% versus 9.8%, P=0.02). No patients were censored before 1 year (median follow-up period 438 days, interquartile range 174-798 days). Survival analyses and inherent log-rank tests showed that LBBB was not associated with higher all-cause mortality, cardiac mortality, or hospitalization for heart failure at 30 days or 1 year. At 30 days, but not at 1 year, group A had a significantly higher rate of pacemaker implantation. CONCLUSIONS: In this registry of high-volume centers, persistent LBBB after CoreValve Revalving System transcatheter aortic valve implantation showed no effect on hard end points. On the other hand, LBBB was associated with a higher short-term rate of pacemaker implantation.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bloqueio de Ramo/complicações , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Bloqueio de Ramo/terapia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Marca-Passo Artificial , Prognóstico , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida , Resultado do Tratamento
11.
Circulation ; 128(3): 244-53, 2013 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-23748467

RESUMO

BACKGROUND: Aortic root rupture is a major concern with balloon-expandable transcatheter aortic valve replacement (TAVR). We sought to identify predictors of aortic root rupture during balloon-expandable TAVR by using multidetector computed tomography. METHODS AND RESULTS: Thirty-one consecutive patients who experienced left ventricular outflow tract (LVOT)/annular/aortic contained/noncontained rupture during TAVR were collected from 16 centers. A caliper-matched sample of 31 consecutive patients without annular rupture, who underwent pre-TAVR multidetector computed tomography served as a control group. Multidetector computed tomography assessment included short- and long-axis diameters and cross-sectional area of the sinotubular junction, annulus, and LVOT, and the presence, location, and extent of calcification of the LVOT, as well. There were no significant differences between the 2 groups in any preoperative clinical and echocardiographic variables. Aortic root rupture was identified in 20 patients and periaortic hematoma in 11. Patients with root rupture had a higher degree of subannular/LVOT calcification quantified by the Agatston score (181.2±211.0 versus 22.5±37.6, P<0.001), and a higher frequency of ≥20% annular area oversizing (79.4% versus 29.0%, P<0.001) and balloon postdilatation (22.6% versus 0.0%, P=0.005). In conditional logistic regression analysis for the matched data, moderate/severe LVOT/subannular calcifications (odds ratio, 10.92; 95% confidence interval, 3.23-36.91; P<0.001) and prosthesis oversizing ≥20% (odds ratio, 8.38; 95% confidence interval, 2.67-26.33; P<0.001) were associated with aortic root contained/noncontained rupture. CONCLUSIONS: This study demonstrates that LVOT calcification and aggressive annular area oversizing are associated with an increased risk of aortic root rupture during TAVR with balloon-expandable prostheses. Larger studies are warranted to confirm these findings.


Assuntos
Angioplastia com Balão/efeitos adversos , Ruptura Aórtica/etiologia , Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/epidemiologia , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/epidemiologia , Calcinose/complicações , Calcinose/diagnóstico por imagem , Calcinose/epidemiologia , Estudos de Coortes , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Modelos Logísticos , Masculino , Valor Preditivo dos Testes , Fatores de Risco , Tomografia Computadorizada por Raios X
12.
Am Heart J ; 168(5): 798-806, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25440810

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an effective therapeutic option for patients with severe aortic stenosis at high risk for surgery. Identification of causes of death after TAVR may help improve patient selection and outcome. METHODS: We enrolled 874 consecutive patients who underwent TAVR at 3 centers using all approved bioprostheses and different access routes. Clinical outcomes during follow-up were defined according to the Valve Academic Research Consortium 2 definitions. Causes of deaths were carefully investigated. RESULTS: Mean logistic European System for Cardiac Operative Risk Evaluation was 23.5% ± 15.3%; Society of Thoracic Surgery score, 9.0% ± 8.2%. The Corevalve (Medtronic, Minneapolis, MN) was used in 41.3%; the Edwards Sapien (Edwards Lifesciences Inc., Irvine, CA) in 57.3%. Vascular access was transfemoral in 75.7%. In-hospital mortality was 5.0%. Cumulative mortality rates at 1 to 3 years were 12.4%, 23.4%, and 31.5%, respectively. Landmark analysis showed a significantly higher incidence of cardiovascular (CV) death in the first 6 months of follow-up and a significantly higher incidence of non-CV death thereafter. At Cox regression analysis, the independent predictors of in-hospital mortality were acute kidney injury grades 2 to 3 (hazard ratio [HR] 3.41) life-threatening bleeding (HR 4.26), major bleeding (HR 4.61), and myocardial infarction (HR 3.89). The independent predictors of postdischarge mortality were chronic obstructive pulmonary disease (HR 1.48), left ventricular ejection fraction at discharge (HR 0.98), and glomerular filtration rate <30 mL/min per 1.73 m(2) (HR 1.64). CONCLUSIONS: Around a third of patients treated with TAVR in daily practice die within the first 3 years of follow-up. Early mortality is predominantly CV, whereas late mortality is mainly non-CV, and it is often due to preexisting comorbidity.


Assuntos
Estenose da Valva Aórtica/cirurgia , Doenças Cardiovasculares/mortalidade , Substituição da Valva Aórtica Transcateter/métodos , Injúria Renal Aguda/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Causas de Morte , Estudos de Coortes , Comorbidade , Feminino , Seguimentos , Taxa de Filtração Glomerular , Hemorragia/epidemiologia , Mortalidade Hospitalar , Humanos , Masculino , Infarto do Miocárdio/epidemiologia , Seleção de Pacientes , Modelos de Riscos Proporcionais , Fatores de Risco , Volume Sistólico , Fatores de Tempo
14.
Ren Fail ; 36(4): 627-30, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24502603

RESUMO

Acute myocardial infarction (AMI) in dialysis patients is associated with high mortality rate. Large randomized controlled trials documenting the benefits of revascularization in the general population have excluded chronic dialysis patients. Few observational data suggest that revascularization may provide a survival benefit compared with medical treatment alone also in these patients. We report a case of a dialysis patient who survived five documented AMIs, underwent five coronary angiographies in 11 years, had several episodes of angina pectoris and underwent percutaneous transluminal coronary angioplasty (PTCA) with stenting and heart surgery for coronary bypassing. It represents a highly unusual therapeutic approach and might contribute to support also in dialysis patients the use of revascularization to improve survival.


Assuntos
Infarto do Miocárdio/terapia , Diálise Renal , Angina Pectoris/complicações , Angioplastia Coronária com Balão , Angiografia Coronária , Ponte de Artéria Coronária , Nefropatias Diabéticas/complicações , Nefropatias Diabéticas/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico por imagem , Recidiva , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/terapia , Stents
15.
JAMA ; 312(2): 162-70, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25005653

RESUMO

IMPORTANCE: Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING, AND PARTICIPANTS: Correlates for survival were evaluated using a multinational valve-in-valve registry that included 459 patients with degenerated bioprosthetic valves undergoing valve-in-valve implantation between 2007 and May 2013 in 55 centers (mean age, 77.6 [SD, 9.8] years; 56% men; median Society of Thoracic Surgeons mortality prediction score, 9.8% [interquartile range, 7.7%-16%]). Surgical valves were classified as small (≤21 mm; 29.7%), intermediate (>21 and <25 mm; 39.3%), and large (≥25 mm; 31%). Implanted devices included both balloon- and self-expandable valves. MAIN OUTCOMES AND MEASURES: Survival, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83.2% (95% CI, 80.8%-84.7%; 62 death events; 228 survivors). Patients in the stenosis group had worse 1-year survival (76.6%; 95% CI, 68.9%-83.1%; 34 deaths; 86 survivors) in comparison with the regurgitation group (91.2%; 95% CI, 85.7%-96.7%; 10 deaths; 76 survivors) and the combined group (83.9%; 95% CI, 76.8%-91%; 18 deaths; 66 survivors) (P = .01). Similarly, patients with small valves had worse 1-year survival (74.8% [95% CI, 66.2%-83.4%]; 27 deaths; 57 survivors) vs with intermediate-sized valves (81.8%; 95% CI, 75.3%-88.3%; 26 deaths; 92 survivors) and with large valves (93.3%; 95% CI, 85.7%-96.7%; 7 deaths; 73 survivors) (P = .001). Factors associated with mortality within 1 year included having small surgical bioprosthesis (≤21 mm; hazard ratio, 2.04; 95% CI, 1.14-3.67; P = .02) and baseline stenosis (vs regurgitation; hazard ratio, 3.07; 95% CI, 1.33-7.08; P = .008). CONCLUSIONS AND RELEVANCE: In this registry of patients who underwent transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic valves, overall 1-year survival was 83.2%. Survival was lower among patients with small bioprostheses and those with predominant surgical valve stenosis.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Sistema de Registros , Análise de Sobrevida , Resultado do Tratamento
16.
Eur J Heart Fail ; 26(5): 1175-1185, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38629741

RESUMO

AIMS: Standardized immunosuppressive therapy (IS) had been previously investigated in biopsy-proven (BP) lymphocytic myocarditis with heart failure (HF). This study evaluated efficacy and safety of tailored IS in BP immune-mediated myocarditis, irrespective of histology and clinical presentation. METHODS AND RESULTS: Consecutive BP myocarditis patients treated with long-term tailored IS on top of optimal medical therapy (OMT), were compared with OMT non-IS controls using propensity-score weighting. The primary outcome was a composite of death or heart transplant, the secondary outcome was a composite of biventricular function, New York Heart Association (NYHA) class variation, and relapse. IS was managed by a multidisciplinary Cardioimmunology Team, involved a safety checklist and active patients' education. Ninety-one IS patients were compared with 267 non-IS patients. IS patients more frequently had systemic immune-mediated diseases (35% vs. 9.7%), lower baseline echocardiographic left ventricular ejection fraction (35% vs. 43%), lower right ventricular fractional area change (34% vs. 41%) and higher frequency of active lymphocytic, eosinophilic and giant cell myocarditis (71% vs. 58%, 12% vs. 1.1%, and 6.6% vs. 1.5%, respectively). At 5-year follow up, no difference was observed in the primary outcome (survival rate 93% in IS vs. 87% in non-IS), but IS patients had a higher relapse rate. Thus, IS patients, with a lower biventricular function and a higher risk profile at baseline, presented similar biventricular function and NYHA class to non-IS patients at follow-up. Minor adverse drug reactions occurred in 13% of patients, all resolved with therapy switch. CONCLUSIONS: Prolonged tailored IS is effective and safe in BP immune-mediated myocarditis irrespective of histology and clinical presentation.


Assuntos
Imunossupressores , Miocardite , Pontuação de Propensão , Humanos , Miocardite/tratamento farmacológico , Masculino , Feminino , Pessoa de Meia-Idade , Imunossupressores/uso terapêutico , Biópsia/métodos , Adulto , Resultado do Tratamento , Estudos Retrospectivos , Miocárdio/patologia , Seguimentos , Ecocardiografia/métodos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/tratamento farmacológico , Volume Sistólico/fisiologia
17.
Circulation ; 126(19): 2335-44, 2012 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-23052028

RESUMO

BACKGROUND: Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry. METHODS AND RESULTS: The Global Valve-in-Valve Registry included 202 patients with degenerated bioprosthetic valves (aged 77.7±10.4 years; 52.5% men) from 38 cardiac centers. Bioprosthesis mode of failure was stenosis (n=85; 42%), regurgitation (n=68; 34%), or combined stenosis and regurgitation (n=49; 24%). Implanted devices included CoreValve (n=124) and Edwards SAPIEN (n=78). Procedural success was achieved in 93.1% of cases. Adverse procedural outcomes included initial device malposition in 15.3% of cases and ostial coronary obstruction in 3.5%. After the procedure, valve maximum/mean gradients were 28.4±14.1/15.9±8.6 mm Hg, and 95% of patients had ≤+1 degree of aortic regurgitation. At 30-day follow-up, all-cause mortality was 8.4%, and 84.1% of patients were at New York Heart Association functional class I/II. One-year follow-up was obtained in 87 patients, with 85.8% survival of treated patients. CONCLUSIONS: The valve-in-valve procedure is clinically effective in the vast majority of patients with degenerated bioprosthetic valves. Safety and efficacy concerns include device malposition, ostial coronary obstruction, and high gradients after the procedure.


Assuntos
Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Falha de Equipamento/estatística & dados numéricos , Saúde Global/estatística & dados numéricos , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Sistema de Registros , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/epidemiologia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Incidência , Masculino , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
18.
Catheter Cardiovasc Interv ; 81(7): 1217-23, 2013 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-23456893

RESUMO

The presence of periprocedural conduction disorders (CDs) and the need for permanent pacemaker (PPM) after transcatheter aortic valve implantation (TAVI) are frequent findings in clinical practice. Notwithstanding, robust information on the prognostic and therapeutic implications of these complications are lacking. The newly occurrence of CD after TAVI seems related to the trauma of the conduction system during procedure. On the contrary, major predictors for PPM implantation after TAVI seem to be the use of CoreValve prosthesis (Medtronic, Minneapolis, MN) and the presence of CD before TAVI. An accurate pre-TAVI screening, careful valve implantation, as well as post-TAVI monitoring must be pursued to prevent avoidable PPM implantation. The aim of this report is to analyze the available data on this field and to propose some practical clinical tips to prevent or to manage these complications.


Assuntos
Estenose da Valva Aórtica/terapia , Arritmias Cardíacas/etiologia , Cateterismo Cardíaco/efeitos adversos , Sistema de Condução Cardíaco/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/terapia , Cateterismo Cardíaco/instrumentação , Estimulação Cardíaca Artificial , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Desenho de Prótese , Fatores de Risco , Resultado do Tratamento
19.
Catheter Cardiovasc Interv ; 82(4): E626-9, 2013 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-23613380

RESUMO

We describe the technical aspects and the possible advantages of a modified anchoring-based technique for the implantation of multiple Amplatzer devices, in a case of large anteroseptal mitral paravalvular leak causing massive regurgitation, which was manaed by antegrade transseptal, single-stage, percutaneous approach. Real-time three-dimensional transesophageal echocardiographic guidance was crucial to ensure successful recrossings of the target defect and the optimal anatomical closure.


Assuntos
Cateterismo Cardíaco/métodos , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca/efeitos adversos , Insuficiência da Valva Mitral/terapia , Falha de Prótese , Ultrassonografia de Intervenção/métodos , Idoso de 80 Anos ou mais , Bioprótese , Cateterismo Cardíaco/instrumentação , Ecocardiografia Doppler em Cores , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Valor Preditivo dos Testes , Desenho de Prótese , Radiografia Intervencionista , Resultado do Tratamento
20.
Catheter Cardiovasc Interv ; 81(2): 376-83, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22461314

RESUMO

OBJECTIVES: We assessed the safety and effectiveness of a selective percutaneous revascularization strategy before TAVI in a single-center prospective registry. BACKGROUND: Management of Coronary Artery Disease (CAD) before Transcatheter Aortic Valve Implantation (TAVI) is not yet established. METHODS: Percutaneous Coronary Intervention (PCI) was scheduled in proximal-to-mid coronary segment lesions on major coronary branches. TAVI was performed by percutaneous trans-femoral, trans-subclavian or trans-apical approach, using either the self-expandable III generation CoreValve (Medtronic, Minneapolis, Minnesota USA) or the Edwards SAPIEN(™) /SAPIEN XT balloon-expandable prosthesis (Edwards Lifesciences Irvine, CA). Clinical and echocardiographic follow-up was collected at 30-day, 3,6,12-month and yearly thereafter. RESULTS: Out of 191 patients who underwent TAVI, 113 (59.2%) had CAD. Mean age was 80.5 ± 6.9 years (57.6% female), logistic EuroSCORE was 21.4% ± 13.4. Twenty-seven (14.1%) patients had previous percutaneous and 29 (15.2%) surgical revascularization. PCI was performed as scheduled before TAVI in 39 (20.4%) patients, without adverse events. Complete anatomical revascularization was obtained in 38 of 113 CAD patients (33.6%). After TAVI, 30-day mortality was 4.2%, and was comparable between CAD and no-CAD patients (P = ns), while 30-day myocardial infarction incidence was 2.6% and occurred only in the CAD group (4.4%, P = 0.06). Overall mortality at follow-up (12.9 ± 9.5 months) was 14.8%, without difference between groups (P = 0.88). At follow-up, five patients underwent coronary revascularization. CONCLUSIONS: In this study, the incidence of CAD is high in patients referred for TAVI. A selective, clinical based, coronary revascularization before TAVI seemed to be safe, and was associated with an outcome similar to those observed in no-CAD TAVI patients.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco , Estenose Coronária/terapia , Implante de Prótese de Valva Cardíaca/métodos , Intervenção Coronária Percutânea , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Estenose Coronária/complicações , Estenose Coronária/mortalidade , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Itália , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Razão de Chances , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA