RESUMO
BACKGROUND: A growing number of clinical trials use various sensors and smartphone applications to collect data outside of the clinic or hospital, raising the question to what extent patients comply with the unique requirements of remote study protocols. Compliance is particularly important in conditions where patients are motorically and cognitively impaired. Here, we sought to understand patient compliance in digital trials of two such pathologies, Parkinson's disease (PD) and Huntington disease (HD). METHODS: Patient compliance was assessed in two remote, six-month clinical trials of PD (n = 51, Clinician Input Study funded by the Michael J. Fox Foundation for Parkinson's Research) and HD (n = 17, sponsored by Teva Pharmaceuticals). We monitored four compliance metrics specific to remote studies: smartphone app-based medication reporting, app-based symptoms reporting, the duration of smartwatch data streaming except while charging, and the performance of structured motor tasks at home. RESULTS: While compliance over time differed between the PD and HD studies, both studies maintained high compliance levels for their entire six month duration. None (- 1%) to a 30% reduction in compliance rate was registered for HD patients, and a reduction of 34 to 53% was registered for the PD study. Both studies exhibited marked changes in compliance rates during the initial days of enrollment. Interestingly, daily smartwatch data streaming patterns were similar, peaking around noon, dropping sharply in the late evening hours around 8 pm, and having a mean of 8.6 daily streaming hours for the PD study and 10.5 h for the HD study. Individual patients tended to have either high or low compliance across all compliance metrics as measured by pairwise correlation. Encouragingly, predefined schedules and app-based reminders fulfilled their intended effect on the timing of medication intake reporting and performance of structured motor tasks at home. CONCLUSIONS: Our findings suggest that maintaining compliance over long durations is feasible, promote the use of predefined app-based reminders, and highlight the importance of patient selection as highly compliant patients typically have a higher adherence rate across the different aspects of the protocol. Overall, these data can serve as a reference point for the design of upcoming remote digital studies. TRIAL REGISTRATION: Trials described in this study include a sub-study of the Open PRIDE-HD Huntington's disease study (TV7820-CNS-20016), which was registered on July 7th, 2015, sponsored by Teva Pharmaceuticals Ltd., and registered on Clinicaltrials.gov as NCT02494778 and EudraCT as 2015-000904-24 .
Assuntos
Doença de Huntington/psicologia , Aplicativos Móveis , Doença de Parkinson/psicologia , Cooperação do Paciente , Smartphone , Idoso , Estudos Clínicos como Assunto , Feminino , Humanos , Doença de Huntington/diagnóstico , Doença de Huntington/terapia , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/diagnóstico , Doença de Parkinson/terapia , Projetos de Pesquisa , Fatores de TempoRESUMO
Previous studies have demonstrated the feasibility and promise of wearable sensors as objective measures of motor impairment in Parkinson disease and essential tremor. However, there are few published studies that have examined such an application in Huntington disease (HD). This report provides an evaluation of the potential to objectively quantify chorea in HD patients using wearable sensor data. Data were derived from a substudy of the phase 2 Open-PRIDE-HD study, where 17 patients were screened and 15 patients enrolled in the substudy and ultimately 10 patients provided sufficient wearable sensor data. The substudy was designed to provide high-resolution data to inform design of predictive algorithms for chorea quantification. During the entire course of the 6-month study, in addition to chorea ratings from 18 in-clinic assessments, 890 home assessments, and 1,388 responses to daily reminders, 33,000 h of high-resolution accelerometer data were captured continuously from wearable smartwatches and smartphones. Despite its limited sample size, our study demonstrates that arm chorea can be characterized using accelerometer data during static assessments. Nonetheless, the small sample size limits the generalizability of the model. The sensor-based model can quantify the chorea level with high correlation to the chorea severity reported by both clinicians and patients. In addition, our analysis shows that the chorea digital signature varies between patients. This work suggests that digital wearable sensors have the potential to support clinical development of medications in patients with movement disorders, such as chorea. However, additional data would be needed from a larger number of HD patients with a full range of chorea severity (none to severe) with and without intervention to validate this potentially predictive technology.
RESUMO
The RGK family of small G-proteins, including Rad, Gem, Rem1, and Rem2, is inducibly expressed in various mammalian tissues and interacts with voltage-dependent calcium channels and Rho kinase. Many questions remain regarding their physiological roles and molecular mechanism. Previous crystallographic studies reported RGK G-domain:guanosine di-phosphate structures. To test whether RGK proteins undergo a nucleotide-induced conformational change, we determined the crystallographic structures of Rad:GppNHp and Rem2:GppNHp to 1.7 and 1.8 Å resolutions, respectively. Also, we characterized the nucleotide-binding properties and conformations for Gem, Rad, and several structure-based mutants using fluorescence spectroscopy. The results suggest that RGK G-proteins may not behave as Ras-like canonical nucleotide-induced molecular switches. Further, the RGK proteins have differing structures and nucleotide-binding properties, which may have implications for their varied action on effectors.
Assuntos
Guanosina Difosfato/química , Guanosina Difosfato/metabolismo , Proteínas Monoméricas de Ligação ao GTP/química , Proteínas Monoméricas de Ligação ao GTP/metabolismo , Proteínas ras/química , Proteínas ras/metabolismo , Animais , Sítios de Ligação , Domínio Catalítico , Cristalografia por Raios X , Transferência Ressonante de Energia de Fluorescência , Fluorimunoensaio , Humanos , Camundongos , Modelos Químicos , Modelos Moleculares , Proteínas Monoméricas de Ligação ao GTP/genética , Mutagênese Sítio-Dirigida , Mutação/genética , Ligação Proteica , Conformação Proteica , Proteínas ras/genéticaRESUMO
Antibody-genes undergo molecular events that produce unique binding-sites that recognize specific epitopes, thus, leading to B-cell clonal variation. As a result, different binding-site structures (paratope internal images) are produced even when two distinct B-cells bind one and the same epitope. Paratope structural variation can be exploited to enable one to evaluate antibody-diversity in a single polyclonal serum sample. This is accomplished through the selection of antibody-specific peptides isolated from combinatorial phage displayed peptide libraries. As an example, we demonstrate the analysis of macaque sera containing passively administered antibodies, given as a therapeutic vaccine and antibodies actively produced by the virus-infected monkeys.