RESUMO
OBJECTIVE: Firefighters are occupationally exposed to per- and polyfluoroalkyl substances (PFAS). This study objective was to compare serum PFAS concentrations in incumbent and recruit firefighters and evaluate temporal trends among recruits. METHODS: Serum PFAS concentrations were measured in 99 incumbent and 55 recruit firefighters at enrollment in 2015-2016, with follow-up 20 to 37 months later for recruits. Linear and logistic regression and linear mixed-effects models were used for analyses. Fireground exposure impact on PFAS concentrations was investigated using adjusted linear and logistic regression models. RESULTS: Incumbents had lower n-PFOA and PFNA than recruits and most PFAS significantly decreased over time among male recruits. No significant links were found between cumulative fireground exposures and PFAS concentrations. CONCLUSIONS: Serum PFAS concentrations were not increased in incumbent firefighters compared with recruits and were not associated with cumulative fireground exposures.