Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 128
Filtrar
1.
Cardiovasc Diabetol ; 23(1): 223, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38943140

RESUMO

BACKGROUND: Sodium-glucose cotransporter 2 inhibitors (SGLT-2i) are glucose-lowering agents used for the treatment of type 2 diabetes mellitus, which also improve heart failure and decrease the risk of cardiovascular complications. Epicardial adipose tissue (EAT) dysfunction was suggested to contribute to the development of heart failure. We aimed to elucidate a possible role of changes in EAT metabolic and inflammatory profile in the beneficial cardioprotective effects of SGLT-2i in subjects with severe heart failure. METHODS: 26 subjects with severe heart failure, with reduced ejection fraction, treated with SGLT-2i versus 26 subjects without treatment, matched for age (54.0 ± 2.1 vs. 55.3 ± 2.1 years, n.s.), body mass index (27.8 ± 0.9 vs. 28.8 ± 1.0 kg/m2, n.s.) and left ventricular ejection fraction (20.7 ± 0.5 vs. 23.2 ± 1.7%, n.s.), who were scheduled for heart transplantation or mechanical support implantation, were included in the study. A complex metabolomic and gene expression analysis of EAT obtained during surgery was performed. RESULTS: SGLT-2i ameliorated inflammation, as evidenced by the improved gene expression profile of pro-inflammatory genes in adipose tissue and decreased infiltration of immune cells into EAT. Enrichment of ether lipids with oleic acid noted on metabolomic analysis suggests a reduced disposition to ferroptosis, potentially further contributing to decreased oxidative stress in EAT of SGLT-2i treated subjects. CONCLUSIONS: Our results show decreased inflammation in EAT of patients with severe heart failure treated by SGLT-2i, as compared to patients with heart failure without this therapy. Modulation of EAT inflammatory and metabolic status could represent a novel mechanism behind SGLT-2i-associated cardioprotective effects in patients with heart failure.


Assuntos
Tecido Adiposo , Insuficiência Cardíaca , Mediadores da Inflamação , Pericárdio , Índice de Gravidade de Doença , Inibidores do Transportador 2 de Sódio-Glicose , Humanos , Inibidores do Transportador 2 de Sódio-Glicose/uso terapêutico , Inibidores do Transportador 2 de Sódio-Glicose/farmacologia , Inibidores do Transportador 2 de Sódio-Glicose/efeitos adversos , Insuficiência Cardíaca/metabolismo , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/tratamento farmacológico , Pessoa de Meia-Idade , Masculino , Feminino , Pericárdio/metabolismo , Pericárdio/efeitos dos fármacos , Tecido Adiposo/efeitos dos fármacos , Tecido Adiposo/metabolismo , Resultado do Tratamento , Mediadores da Inflamação/metabolismo , Volume Sistólico/efeitos dos fármacos , Anti-Inflamatórios/uso terapêutico , Anti-Inflamatórios/farmacologia , Função Ventricular Esquerda/efeitos dos fármacos , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Mellitus Tipo 2/metabolismo , Diabetes Mellitus Tipo 2/diagnóstico , Metabolômica , Biomarcadores/sangue , Tecido Adiposo Epicárdico
2.
Pediatr Transplant ; 28(1): e14626, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37853942

RESUMO

BACKGROUND: Heart transplantation (HTx) is an established therapeutic option for children with end-stage heart failure. Comprehensive pediatric nationwide HTx program was introduced in 2014 in the Czech Republic. The aim of this study was to evaluate its mid-term characteristics and outcomes and to compare them with international data. METHODS: Retrospective observational study, including all patients who underwent HTx from June 2014 till December 2022. Data from the institutional database were used for descriptive statistics and survival analyses. RESULTS: A total of 30 HTx were performed in 29 patients with congenital heart disease (CHD, N = 15, single ventricular physiology in 10 patients) and cardiomyopathy (CMP, N = 14). Ten patients were bridged to HTx by durable left ventricular assist devices (LVADs) for a mean duration of 104 (SD 89) days. There was one early and one late death during median follow-up of 3.3 (IQR 1.3-6.1) years. Survival probability at 5 years after HTx was 93%. Two patients underwent re-transplantation (one of them in an adult center). Significant rejection-free survival at 1, 3, and 6 years after HTx was 76%, 63%, and 63%, respectively. CONCLUSIONS: The introduced pediatric HTx program reflects the complexity of the treated population, with half of the patients having complex CHD and one-third being bridged to HTx by LVADs. Mid-term results are comparable to worldwide data. The data confirm the possibility of establishing a successful nationwide pediatric HTx program in a relatively small population country with well-developed pediatric cardiovascular care and other transplantation programs.


Assuntos
Cardiomiopatias , Cardiopatias Congênitas , Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Adulto , Humanos , Criança , Insuficiência Cardíaca/cirurgia , República Tcheca , Estudos Retrospectivos , Resultado do Tratamento
3.
Artif Organs ; 48(10): 1168-1179, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38803239

RESUMO

BACKGROUND: Stroke after durable left ventricular assist device (d-LVAD) implantation portends high mortality. The incidence of ischemic and hemorrhagic stroke and the impact on stroke outcomes of temporary mechanical circulatory support (tMCS) management among patients requiring bridge to d-LVAD with micro-axial flow-pump (mAFP, Abiomed) is unsettled. METHODS: Consecutive patients, who underwent d-LVAD implantation after being bridged with mAFP at 19 institutions, were retrospectively included. The incidence of early ischemic and hemorrhagic stroke after d-LVAD implantation (<60 days) and association of pre-d-LVAD characteristics and peri-procedural management with a specific focus on tMCS strategies were studied. RESULTS: Among 341 patients, who underwent d-LVAD implantation after mAFP implantation (male gender 83.6%, age 58 [48-65] years, mAFP 5.0/5.5 72.4%), the early ischemic stroke incidence was 10.8% and early hemorrhagic stroke 2.9%. The tMCS characteristics (type of mAFP device and access, support duration, upgrade from intra-aortic balloon pump, ECMELLA, ECMELLA at d-LVAD implantation, hemolysis, and bleeding) were not associated with ischemic stroke after d-LVAD implant. Conversely, the device model (mAFP 2.5/CP vs. mAFP 5.0/5.5: HR 5.6, 95%CI 1.4-22.7, p = 0.015), hemolysis on mAFP support (HR 10.5, 95% CI 1.3-85.3, p = 0.028) and ECMELLA at d-LVAD implantation (HR 5.0, 95% CI 1.4-18.7, p = 0.016) were associated with increased risk of hemorrhagic stroke after d-LVAD implantation. Both early ischemic (HR 2.7, 95% CI 1.9-4.5, p < 0.001) and hemorrhagic (HR 3.43, 95% CI 1.49-7.88, p = 0.004) stroke were associated with increased 1-year mortality. CONCLUSIONS: Among patients undergoing d-LVAD implantation following mAFP support, tMCS characteristics do not impact ischemic stroke occurrence, while several factors are associated with hemorrhagic stroke suggesting a proactive treatment target to reduce this complication.


Assuntos
Coração Auxiliar , Sistema de Registros , Humanos , Coração Auxiliar/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Incidência , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/epidemiologia , Insuficiência Cardíaca/terapia , AVC Isquêmico/etiologia , AVC Isquêmico/epidemiologia , Resultado do Tratamento , Acidente Vascular Cerebral Hemorrágico/etiologia , Acidente Vascular Cerebral Hemorrágico/epidemiologia
4.
Arterioscler Thromb Vasc Biol ; 42(4): 470-480, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35139659

RESUMO

BACKGROUND: Carmat bioprosthetic total artificial heart (Aeson; A-TAH) is a pulsatile and autoregulated device. The aim of this study is to evaluate level of hemolysis potential acquired von Willebrand syndrome after A-TAH implantation. METHODS: We examined the presence of hemolysis and acquired von Willebrand syndrome in adult patients receiving A-TAH support (n=10) during their whole clinical follow-up in comparison with control subjects and adult patients receiving Heartmate II or Heartmate III support. We also performed a fluid structure interaction model coupled with computational fluid dynamics simulation to evaluate the A-TAH resulting shear stress and its distribution in the blood volume. RESULTS: The cumulative duration of A-TAH support was 2087 days. A-TAH implantation did not affect plasma free hemoglobin over time, and there was no association between plasma free hemoglobin and cardiac output or beat rate. For VWF (von Willebrand factor) evaluation, A-TAH implantation did not modify multimers profile of VWF in contrast to Heartmate II and Heartmate III. Furthermore, fluid structure interaction coupled with computational fluid dynamics showed a gradually increase of blood damage according to increase of cardiac output (P<0.01), however, the blood volume fraction that endured significant shear stresses was always inferior to 0.03% of the volume for both ventricles in all regimens tested. An inverse association between cardiac output, beat rate, and high-molecular weight multimers ratio was found. CONCLUSIONS: We demonstrated that A-TAH does not cause hemolysis or AWVS. However, relationship between HMWM and cardiac output depending flow confirms relevance of VWF as a biological sensor of blood flow, even in normal range.


Assuntos
Coração Artificial , Doenças de von Willebrand , Adulto , Coração Artificial/efeitos adversos , Hemoglobinas , Hemólise , Humanos , Fator de von Willebrand
5.
JAMA ; 330(22): 2171-2181, 2023 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-37950897

RESUMO

IMPORTANCE: Left ventricular assist devices (LVADs) enhance quality and duration of life in advanced heart failure. The burden of nonsurgical bleeding events is a leading morbidity. Aspirin as an antiplatelet agent is mandated along with vitamin K antagonists (VKAs) with continuous-flow LVADs without conclusive evidence of efficacy and safety. OBJECTIVE: To determine whether excluding aspirin as part of the antithrombotic regimen with a fully magnetically levitated LVAD is safe and decreases bleeding. DESIGN, SETTING, and PARTICIPANTS: This international, randomized, double-blind, placebo-controlled study of aspirin (100 mg/d) vs placebo with VKA therapy in patients with advanced heart failure with an LVAD was conducted across 51 centers with expertise in treating patients with advanced heart failure across 9 countries. The randomized population included 628 patients with advanced heart failure implanted with a fully magnetically levitated LVAD (314 in the placebo group and 314 in the aspirin group), of whom 296 patients in the placebo group and 293 in the aspirin group were in the primary analysis population, which informed the primary end point analysis. The study enrolled patients from July 2020 to September 2022; median follow-up was 14 months. Intervention: Patients were randomized in a 1:1 ratio to receive aspirin (100 mg/d) or placebo in addition to an antithrombotic regimen. MAIN OUTCOMES AND MEASURES: The composite primary end point, assessed for noninferiority (-10% margin) of placebo, was survival free of a major nonsurgical (>14 days after implant) hemocompatibility-related adverse events (including stroke, pump thrombosis, major bleeding, or arterial peripheral thromboembolism) at 12 months. The principal secondary end point was nonsurgical bleeding events. RESULTS: Of the 589 analyzed patients, 77% were men; one-third were Black and 61% were White. More patients were alive and free of hemocompatibility events at 12 months in the placebo group (74%) vs those taking aspirin (68%). Noninferiority of placebo was demonstrated (absolute between-group difference, 6.0% improvement in event-free survival with placebo [lower 1-sided 97.5% CI, -1.6%]; P < .001). Aspirin avoidance was associated with reduced nonsurgical bleeding events (relative risk, 0.66 [95% confidence limit, 0.51-0.85]; P = .002) with no increase in stroke or other thromboembolic events, a finding consistent among diverse subgroups of patient characteristics. CONCLUSIONS AND RELEVANCE: In patients with advanced heart failure treated with a fully magnetically levitated LVAD, avoidance of aspirin as part of an antithrombotic regimen, which includes VKA, is not inferior to a regimen containing aspirin, does not increase thromboembolism risk, and is associated with a reduction in bleeding events. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04069156.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral , Tromboembolia , Masculino , Humanos , Feminino , Aspirina/efeitos adversos , Coração Auxiliar/efeitos adversos , Fibrinolíticos/efeitos adversos , Método Duplo-Cego , Insuficiência Cardíaca/fisiopatologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/tratamento farmacológico , Inibidores da Agregação Plaquetária/efeitos adversos , Hemorragia/etiologia , Tromboembolia/etiologia , Tromboembolia/prevenção & controle
6.
J Appl Biomed ; 21(4): 174-179, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38112456

RESUMO

INTRODUCTION: False aneurysms in the thoracic aorta are dangerous complications that can occur after cardiac surgery. They often result in high mortality rates. These aneurysms are caused by damage to all layers of the aortic wall. This study aimed to pinpoint the area of the experimental specimen (native vessel, anastomosis, or prosthetic graft) with the greatest deformation, to determine whether a false aneurysm is likely to develop in the anastomotic portion. METHODS: We conducted the inflation-extension test by performing eight cycles ranging from 0 to 20. The pressure sampling frequency was 100 Hz, and each cycle lasted approximately 34 seconds, resulting in a loading frequency of 0.03 Hz. During the experiment, each camera captured 3,000 frames. Based on the data collected, we evaluated and compared the loading stages of cycle 1 and cycle 8. RESULTS AND DISCUSSION: During loading, the native vessel experienced a dominant deformation of approximately 7% in the circumferential direction. The prosthetic graft, which had a longitudinal construction, deformed by approximately 8% in the axial direction. The prosthetic graft, on the other hand, only experienced a deformation of up to 1.5% in the circumferential direction, which was about 5 times smaller than the deformation of the native vessel. The anastomosis area was very stiff and showed minimal deformation. Additionally, there was little difference in the mechanical response between the first C1 and the eighth C8 cycle. CONCLUSION: Based on the available evidence, it can be inferred that aortic false aneurysms are more likely to form just behind the suture lines in the native aorta, which is more elastic compared to stiff sections of anastomosis and prosthetic graft. Numerous pulsations of the native vessel will likely cause the impairment of the aorta at the margin of the anastomosis. This will lead to disruption of the aortic wall and false aneurysm formation in the native vessel near the area of anastomosis.


Assuntos
Falso Aneurisma , Aneurisma Aórtico , Humanos , Aorta Torácica/cirurgia , Falso Aneurisma/diagnóstico , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Aneurisma Aórtico/complicações , Anastomose Cirúrgica/efeitos adversos
7.
Artif Organs ; 46(5): 813-826, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34904255

RESUMO

BACKGROUND: We investigated the clinical outcomes after cardiac valvular surgery procedures concomitant (CCPs) with left ventricular assist device (LVAD) implantation compared to propensity score (PS) matched controls using the European Registry for Patients with Mechanical Circulatory Support (EUROMACS) data. METHODS: Between 2006 and 2018, 2760 continuous-flow LVAD patients were identified. Of these, 533 underwent a CCP during the LVAD implant. RESULTS: Cardiopulmonary bypass time (p < 0.001) and time for implant (p < 0.001) were both significantly longer in the LVAD+CCP group. Hospital mortality was comparable between the two groups from the unmatched population (15.7% vs. 14.1%, p = 0.073). Similarly, short-to-mid-term survival was similar in both groups, with 1-year, 3-year, and 5-year survival rates of 67.9%, 48.2%, and 27.7% versus 66.4%, 46.1%, and 26%, respectively (log-rank, p = 0.25). The results were similar in the PS-matched population. Hospital mortality was comparable between the two groups (18.9% vs. 17.4%, p = 0.074). The short-to-mid-term Kaplan-Meier survival analysis was similar for both groups, with 1-year, 3-year, and 5-year survival rates of 63.4%, 49.2%, and 24.7% versus 66.5%, 46%, and 25.1%, respectively (log-rank, p = 0.81). In the unmatched population, LVAD+CCP patients had longer intensive care unit (ICU) stays (p < 0.0001), longer mechanical ventilation time (p = 0.001), a higher rate of temporary right ventricular assist device (RVAD) support (p = 0.033), and a higher rate of renal replacement therapy (n = 35, 6.6% vs. n = 89, 4.0%, p = 0.014). In the PS-matched population, the LVAD+CCP patients had longer ICU stays (p = 0.019) and longer mechanical ventilation time (p = 0.002). CONCLUSIONS: The effect of additive valvular procedures (CCPs) does not seem to affect short-term survival, significantly, based on our registry data analysis. However, the decision to perform CCPs should be balanced with the projected type of surgery and preoperative characteristics. LVAD+CCP patients remain a delicate population and adverse device-related events should be strictly monitored and managed.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
8.
Int J Mol Sci ; 23(17)2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36077376

RESUMO

(1) Background: C1q TNF-related protein 3 (CTRP3) is an adipokine with anti-inflammatory and cardioprotective properties. In our study, we explored changes in serum CTRP3 and its gene expression in epicardial (EAT) and subcutaneous (SAT) adipose tissue in patients with and without coronary artery disease (CAD) and type 2 diabetes mellitus (T2DM) undergoing elective cardiac surgery. (2) Methods: SAT, EAT, and blood samples were collected at the start and end of surgery from 34 patients: (i) 11 without CAD or T2DM, (ii) 14 with CAD and without T2DM, and (iii) 9 with both CAD and T2DM. mRNA levels of CTRP3 were assessed by quantitative reverse transcription PCR. Circulating levels of CTRP3 and other factors were measured using ELISA and Luminex Multiplex commercial kits. (3) Results: Baseline plasma levels of TNF-α and IL6 did not differ among the groups and increased at the end of surgery. Baseline circulating levels of CTRP3 did not differ among the groups and decreased after surgery. In contrast, baseline CTRP3 mRNA levels in EAT were significantly decreased in CAD/T2DM group, while no differences were found for TNF-α and IL6 gene expression. (4) Conclusions: Our data suggest that decreased EAT mRNA levels of CTRP3 could contribute to higher risk of atherosclerosis in patients with CAD and T2DM.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Doença da Artéria Coronariana , Diabetes Mellitus Tipo 2 , Tecido Adiposo/metabolismo , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/genética , Doença da Artéria Coronariana/cirurgia , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/genética , Diabetes Mellitus Tipo 2/cirurgia , Humanos , Interleucina-6/metabolismo , Pericárdio/metabolismo , RNA Mensageiro/metabolismo , Fator de Necrose Tumoral alfa/genética , Fator de Necrose Tumoral alfa/metabolismo
9.
J Card Surg ; 36(10): 3944-3947, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34296475

RESUMO

Ventricular septal defect (VSD) is a severe complication of myocardial infarction (MI) with a high mortality rate. We report a case of a large post-MI VSD treated with percutaneous venoarterial extracorporeal membrane oxygenation (VA-ECMO) to restore hemodynamic stability and to avoid surgery in the acute setting. VSD closure with endoventricular patch and implantation of biventricular assist device (BiVAD) was arranged sixteen days after MI. Because of no signs of myocardial recovery, implantation of durable left ventricular assist device (LVAD) as a bridge to transplant was provided, leaving right ventricular assist device (RVAD) to right ventricle recovery. RVAD was explanted 18 days after durable LVAD placement and the patient was discharged home two months after MI. The use of durable LVAD is a unique solution that can be applied in selected patients with MI-VSD and heart failure.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Comunicação Interventricular , Coração Auxiliar , Infarto do Miocárdio , Insuficiência Cardíaca/terapia , Comunicação Interventricular/cirurgia , Humanos , Infarto do Miocárdio/complicações , Resultado do Tratamento
10.
Int J Mol Sci ; 22(14)2021 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-34299034

RESUMO

Studying the long-term impact of continuous-flow left ventricular assist device (CF-LVAD) offers an opportunity for a complex understanding of the pathophysiology of vascular changes in aortic tissue in response to a nonphysiological blood flow pattern. Our study aimed to analyze aortic mRNA/miRNA expression changes in response to long-term LVAD support. Paired aortic samples obtained at the time of LVAD implantation and at the time of heart transplantation were examined for mRNA/miRNA profiling. The number of differentially expressed genes (Pcorr < 0.05) shared between samples before and after LVAD support was 277. The whole miRNome profile revealed 69 differentially expressed miRNAs (Pcorr < 0.05). Gene ontology (GO) analysis identified that LVAD predominantly influenced genes involved in the extracellular matrix and collagen fibril organization. Integrated mRNA/miRNA analysis revealed that potential targets of miRNAs dysregulated in explanted samples are mainly involved in GO biological process terms related to dendritic spine organization, neuron projection organization, and cell junction assembly and organization. We found differentially expressed genes participating in vascular tissue engineering as a consequence of LVAD duration. Changes in aortic miRNA levels demonstrated an effect on molecular processes involved in angiogenesis.


Assuntos
Valvopatia Aórtica/patologia , Regulação da Expressão Gênica , Insuficiência Cardíaca/cirurgia , Transplante de Coração/efeitos adversos , Coração Auxiliar/efeitos adversos , MicroRNAs/genética , RNA Mensageiro/metabolismo , Adolescente , Adulto , Idoso , Valvopatia Aórtica/etiologia , Valvopatia Aórtica/metabolismo , Feminino , Perfilação da Expressão Gênica , Insuficiência Cardíaca/patologia , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , RNA Mensageiro/genética , Adulto Jovem
11.
Int J Mol Sci ; 22(9)2021 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-33926122

RESUMO

The aim of our study was to analyze mitochondrial and endoplasmic reticulum (ER) gene expression profiles in subcutaneous (SAT) and epicardial (EAT) adipose tissue, skeletal muscle, and myocardium in patients with and without CAD undergoing elective cardiac surgery. Thirty-eight patients, 27 with (CAD group) and 11 without CAD (noCAD group), undergoing coronary artery bypass grafting and/or valvular surgery were included in the study. EAT, SAT, intercostal skeletal muscle, and right atrium tissue and blood samples were collected at the start and end of surgery; mRNA expression of selected mitochondrial and ER stress genes was assessed using qRT-PCR. The presence of CAD was associated with decreased mRNA expression of most of the investigated mitochondrial respiratory chain genes in EAT, while no such changes were seen in SAT or other tissues. In contrast, the expression of ER stress genes did not differ between the CAD and noCAD groups in almost any tissue. Cardiac surgery further augmented mitochondrial dysfunction in EAT. In our study, CAD was associated with decreased expression of mitochondrial, but not endoplasmic reticulum stress genes in EAT. These changes may contribute to the acceleration of coronary atherosclerosis.


Assuntos
Doença da Artéria Coronariana/genética , Estresse do Retículo Endoplasmático/genética , Transcriptoma/genética , Tecido Adiposo/metabolismo , Idoso , Doença da Artéria Coronariana/fisiopatologia , Retículo Endoplasmático/genética , Retículo Endoplasmático/metabolismo , Estresse do Retículo Endoplasmático/fisiologia , Feminino , Expressão Gênica/genética , Perfilação da Expressão Gênica/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Mitocôndrias/genética , Mitocôndrias/metabolismo , Músculo Esquelético/metabolismo , Miocárdio/metabolismo , Pericárdio/metabolismo , RNA Mensageiro/genética , Gordura Subcutânea/metabolismo
12.
J Proteome Res ; 19(10): 3993-4003, 2020 10 02.
Artigo em Inglês | MEDLINE | ID: mdl-32830500

RESUMO

Coronary artery disease is one of the most frequent causes of morbidity and mortality worldwide. It is even more prevalent in patients with type 2 diabetes mellitus who suffer from obesity and increased accumulation of epicardial fat with a possible contributing role in the development of coronary artery disease. We performed an MS-based lipidomic analysis of subcutaneous and epicardial adipose tissue in 23 patients with coronary artery disease stratified for the presence/absence of type 2 diabetes mellitus and a control group of 13 subjects aiming at identification of factors from epicardial fat contributing to the development of coronary artery disease. The samples of adipose tissues were obtained during elective cardiac surgery. They were extracted and analyzed with and without previous triacylglycerols separation by high-pressure liquid chromatography-mass spectrometry (HPLC-MS). Multivariate and univariate analyses were performed. Lipidomics data were correlated with biochemical parameters. We identified multiple changes in monoacylglycerols, diacylglycerols, triacylglycerols, glycerophosphatidylserines, glycerophosphatidylethanolamines, glycerophosphatidylcholines, ceramides, sphingomyelins, and derivatives of cholesterol. Observed changes included molecules with fatty acids with odd (15:0, 15:1, 17:0, 17:1) and even (10:0, 12:0, 14:0, 16:0, 16:1, 18:0, 18:1, 18:2, 20:4, 20:1, 22:0) fatty acids in both types of adipose tissue. More pronounced changes were detected in epicardial adipose tissue compared to subcutaneous adipose tissue of patients with coronary artery disease and type 2 diabetes. Lipidomic analysis of subcutaneous and epicardial adipose tissue revealed different profiles for patients with coronary artery disease and type 2 diabetes, which might be related to coronary artery disease and the presence of type 2 diabetes.


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus Tipo 2 , Tecido Adiposo , Humanos , Lipídeos , Pericárdio , Gordura Subcutânea
14.
J Card Fail ; 26(7): 580-587, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32417377

RESUMO

BACKGROUND: In patients with a continuous-flow left ventricular assist device, preimplant predictors of poor physical performance are not well-described. We aimed to identify predictors of inability to walk more than 300 m on 6-minute walk test (6MWT) 6 months after HeartMate 3 implantation. METHODS AND RESULTS: Using data from the European Registry of Patients Implanted With a Full Magnetically Levitated LVAD, patients with available 6MWT at 6 months after implantation were included (N = 194) and grouped according to 6MWT distance (6MWD) of >300 m (n = 150) or 6MWD of <300 m (n = 44). Patients walking <300 m were older (60 ± 10 vs 52 ± 12 years; P < .001), more often New York Heart Association functional class IV (63% vs 42%; P = .03), and more often had type 2 diabetes (43% vs 17%; P < .001) at implantation. Atrial fibrillation was seen in 57% in those with a 6MWT of <300 m vs 31% in those walking longer (P < .002). Further, hemoglobin and estimated glomerular filtration rate was lower in those walking <300 m (both P < .01). In multivariable regression analysis, independent predictors of a 6MWD of <300 m were: atrial fibrillation (odds ratio [OR], 3.22; 95% confidence interval [CI], 1.12-8.67), older age (OR for 10-year increment, 2.81; 95% CI, 1.55-5.07), New York Heart Association functional class IV (OR, 3.37; 95% CI, 1.27-8.98), and Interagency Registry for Mechanically Assisted Circulatory Support profile 1 or 2 (OR, 6.53; 95% CI, 1.92-22.19). CONCLUSIONS: Six months after HeartMate 3 implantation, 77% of patients walked >300 meters in 6 minutes. Apart from age and measures of heart failure severity, atrial fibrillation at implantation is an independent predictor of low 6MWD at 6 months after implantation.


Assuntos
Diabetes Mellitus Tipo 2 , Insuficiência Cardíaca , Coração Auxiliar , Idoso , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Humanos , Sistema de Registros , Resultado do Tratamento
15.
Scand Cardiovasc J ; 54(5): 306-314, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32552049

RESUMO

Objectives: Development of right ventricular failure (RVF) after left ventricular assist device (LVAD) implantation remains a leading cause of perioperative morbidity, end-organ dysfunction and mortality. The objective of this study was to investigate whether the etiology of HF (ischemic HF versus non-ischemic HF) affects the risk of RVF within admission for LVAD implantation and during long-term follow-up. Methods: Between January 2011 and June 27, 2018, 3536 patients were prospectively enrolled into EUROMACS registry. Adult patients (>18 years) who received a first time LVAD were included. When excluding patients with congenital, restrictive, hypertrophic, valvular cardiomyopathies, and myocarditis the total population consisted of 2404 patients. Results: The total cohort consists of 2404 patients. Mean age were 55 years and predominantly male sex [2024 (84.2%)]. At the time of LVAD implantation 1355 (56.4%) patients had ischemic HF and 1049 (43.6%) patients had non-ischemic HF. The incidence of RVF was significantly increased in the non-ischemic HF group in the adjusted model (p = .026). The relative risk difference for RVF in patients with non-ischemic HF was in the adjusted model increased by an absolute value of 5.1% (95% CI: 0.61-9.6). In the ischemic HF group 76 patients (13.4%) developed late RVF and 62 patients (14.8%) in the non-ischemic HF group (p = .56). No differences in occurrence of RVF between HF etiology was observed after 2 and 4 years of follow-up, respectively (crude: p = .25, adjusted (sex and age) p = .2 and crude: p = .59, adjusted (sex and age) p = .44). Conclusions: Patients with non-ischemic HF undergoing LVAD had an increased incidence of early RVF compared to patients with ischemic HF in a large European population. During follow-up after discharge 14% patients developed RVF. We recommend HF etiology to be considered in identifying patients who are at risk for postoperative RVF after LVAD implantation.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Disfunção Ventricular Direita/epidemiologia , Função Ventricular Esquerda , Função Ventricular Direita , Adulto , Europa (Continente)/epidemiologia , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/fisiopatologia
17.
J Card Fail ; 25(1): 36-43, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30472281

RESUMO

BACKGROUND: The Heartmate 3 (HM3) is a Conformiteé Européenne mark-approved left ventricular (LV) assist device (LVAD) with fully magnetically levitated rotor and features consisting of a wide range operational speeds, wide flow paths, and artificial pulse. We performed a hemodynamic-echocardiographic speed optimization evaluation in HM3-implanted patients to achieve optimal LV- and right ventricular (RV) shape. METHODS AND RESULTS: Sixteen HM3 patients underwent pump speed ramp tests with right heart catheterization. Three-dimensional echocardiographic (3DE) LV and RV datasets (Philips) were acquired, and volumetric (Tomtec) and shape (custom software) analyses were performed (LV: sphericity, conicity; RV: septal and free-wall curvatures). Data were recorded at up to 13 speed settings. Speed changes were in 100-rpm steps, starting at 4600 rpm and ramping up to 6200 rpm. 3DE was feasible in 50% of the patients. Mean original speed was 5306 ± 148 rpm. LV end-diastolic (ED) diameter (-0.15 ± 0.09 cm/100 rpm) and volumes (ED: 269 ± 109 mL to 175 ± 90 mL; end-systolic [ES]: 234 ± 111 mL to 146 ± 81 mL) progressively decreased as the shape became less spherical and more conical; RV volumes initially remained stable, but at higher speeds increased (ED: from 148 ± 64 mL to 181 ± 92 mL; ES: 113 ± 63 mL to 130 ± 69 mL). On average, the RV septum became less convex (bulging toward the LV) at the highest speeds. CONCLUSIONS: LV and RV shape changes were noted in HM3-supported patients. Although a LV volumetric decrease and shape improvement was consistently noted, RV volumes grew in response to increase in speed above a certain point. A next concern would be whether understanding of morphologic and function changes in LV and RV during LVAD speed change assessed with the use of 3DE helps to optimize LVAD speed settings and improve clinical outcomes.


Assuntos
Ecocardiografia Tridimensional/tendências , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Coração Auxiliar/tendências , Magnetoterapia/tendências , Idoso , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/tendências , Feminino , Ventrículos do Coração/cirurgia , Humanos , Magnetoterapia/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
18.
Mediators Inflamm ; 2019: 5481725, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31210749

RESUMO

Dendritic cells (DCs) are professional antigen-presenting cells contributing to regulation of lymphocyte immune response. DCs are divided into two subtypes: CD11c-positive conventional or myeloid (cDCs) and CD123-positive plasmacytoid (pDCs) DCs. The aim of the study was to assess DCs (HLA-DR+ lineage-) and their subtypes by flow cytometry in peripheral blood and subcutaneous (SAT) and epicardial (EAT) adipose tissue in subjects with (T2DM, n = 12) and without (non-T2DM, n = 17) type 2 diabetes mellitus undergoing elective cardiac surgery. Subjects with T2DM had higher fasting glycemia (8.6 ± 0.7 vs. 5.8 ± 0.2 mmol/l, p < 0.001) and glycated hemoglobin (52.0 ± 3.4 vs. 36.9 ± 1.0 mmol/mol, p < 0.001) and tended to have more pronounced inflammation (hsCRP: 9.8 ± 3.1 vs. 5.1 ± 1.9 mg/ml, p = 0.177) compared with subjects without T2DM. T2DM was associated with reduced total DCs in SAT (1.57 ± 0.65 vs. 4.45 ± 1.56% for T2DM vs. non-T2DM, p = 0.041) with a similar, albeit insignificant, trend in EAT (0.996 ± 0.33 vs. 2.46 ± 0.78% for T2DM vs. non-T2DM, p = 0.171). When analyzing DC subsets, no difference in cDCs was seen between any of the studied groups or adipose tissue pools. In contrast, pDCs were increased in both SAT (13.5 ± 2.0 vs. 4.6 ± 1.9% of DC cells, p = 0.005) and EAT (29.1 ± 8.7 vs. 8.4 ± 2.4% of DC, p = 0.045) of T2DM relative to non-T2DM subjects as well as in EAT of the T2DM group compared with corresponding SAT (29.1 ± 8.7 vs. 13.5 ± 2.0% of DC, p = 0.020). Neither obesity nor coronary artery disease (CAD) significantly influenced the number of total, cDC, or pDC in SAT or EAT according to multiple regression analysis. In summary, T2DM decreased the amount of total dendritic cells in subcutaneous adipose tissue and increased plasmacytoid dendritic cells in subcutaneous and even more in epicardial adipose tissue. These findings suggest a potential role of pDCs in the development of T2DM-associated adipose tissue low-grade inflammation.


Assuntos
Tecido Adiposo/metabolismo , Doença da Artéria Coronariana/metabolismo , Células Dendríticas/metabolismo , Diabetes Mellitus Tipo 2/metabolismo , Obesidade/metabolismo , Tecido Adiposo/imunologia , Idoso , Doença da Artéria Coronariana/imunologia , Diabetes Mellitus Tipo 2/imunologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/imunologia , Pericárdio/imunologia , Pericárdio/metabolismo , Gordura Subcutânea/imunologia , Gordura Subcutânea/metabolismo
19.
Clin Transplant ; 32(10): e13390, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30144327

RESUMO

The study objective is to quantify the impact of donor and recipient variables on heart transplant survival in recipients with a significant proportion of implanted continuous-flow left ventricular assist devices (LVADs). This is a prospective cohort study of International Society for Heart and Lung Transplantation (ISHLT) Registry that includes all primary heart-alone transplants in adult recipients (January 2005 and June 2013, N = 15 532, 27% LVADs). Donor and recipient characteristics were assessed for association with death or graft failure within 90 days and between 90 days and 5 years after transplantation. On Cox proportional hazard model donor cause of death other than head trauma (hazard ratio [HR] 1.985, P < 0.0001), recipient congenital (HR 2.7555, P < 0.0001) and ischemic (HR 1.165, P = 0.0383) vs dilated etiology and female donor heart transplanted into male recipient (HR 1.207, P = 0.0354) were predictors of death or graft failure within 90 days. Between 90 days and 5 years, donor cigarette use (HR 1.232, P = 0.0001), recipient cigarette use (HR 1.193, P = 0.0003), diabetes (HR 1.159, P = 0.0050), arterial hypertension (HR 1.129, P = 0.0115), and ischemic vs dilative cardiomyopathy had an increased probability of death or graft failure.


Assuntos
Rejeição de Enxerto/mortalidade , Transplante de Coração/mortalidade , Coração Auxiliar/estatística & dados numéricos , Complicações Pós-Operatórias/mortalidade , Medição de Risco/métodos , Doadores de Tecidos/provisão & distribuição , Transplantados/estatística & dados numéricos , Adulto , Análise Fatorial , Feminino , Seguimentos , Sobrevivência de Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Fatores de Risco , Taxa de Sobrevida , Adulto Jovem
20.
Vnitr Lek ; 64(1): 66-71, 2018.
Artigo em Tcheco | MEDLINE | ID: mdl-29498878

RESUMO

Ventricular assist devices are an important therapeutic modality in advanced surgical therapy of end-stage heart failure. Previously most frequently used devices generated mainly non-pulsatile blood flow. Despite indisputable clinical success of this therapy, we encounter complications specific to the devices generating continuous flow. Complications are mainly attributed to changes in shear stress and subsequent changes of the blood vessel characteristics, mainly of endothelium. Effect of continuous flow on the vasculature and blood elements, therefore, became a subject of intense recent research. Effect of continuous flow on the vascular bed is subject of intensive research. Widespread methods used in angiology measuring the state of vasculature are based mainly on imaging modalities and on the presence of pulsatile flow; therefore, under circumstances of non-pulsatile flow their use is limited and the attention is shifted also to laboratory methods, namely to detection of circulating indicators of vascular damage. Therefore, in our recent studies of the effect of mechanical ventricular assist devices on the blood flow we exploit combination of imaging and laboratory methods, including measurements of circulating microparticles and endothelial progenitor cells. Based on these studies interesting data were obtained studying the effect of implantation of mechanical cardiac support on the dynamics of vascular changes taking into account also response to changes of blood flow characteristics. In this paper we summarize our observations.Key words: continuous flow - endothelial progenitor cells - mechanical circulatory support - microparticles - vascular damage.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Fluxo Pulsátil
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA