Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Arch Psychiatry Clin Neurosci ; 274(3): 685-696, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37668723

RESUMO

Treatment-resistant depression is a severe form of major depressive disorder and deep brain stimulation is currently an investigational treatment. The stimulation's therapeutic effect may be explained through the functional and structural connectivities between the stimulated area and other brain regions, or to depression-associated networks. In this longitudinal, retrospective study, four female patients with treatment-resistant depression were implanted for stimulation in the nucleus accumbens area at our center. We analyzed the structural and functional connectivity of the stimulation area: the structural connectivity was investigated with probabilistic tractography; the functional connectivity was estimated by combining patient-specific stimulation volumes and a normative functional connectome. These structural and functional connectivity profiles were then related to four clinical outcome scores. At 1-year follow-up, the remission rate was 66%. We observed a consistent structural connectivity to Brodmann area 25 in the patient with the longest remission phase. The functional connectivity analysis resulted in patient-specific R-maps describing brain areas significantly correlated with symptom improvement in this patient, notably the prefrontal cortex. But the connectivity analysis was mixed across patients, calling for confirmation in a larger cohort and over longer time periods.


Assuntos
Estimulação Encefálica Profunda , Transtorno Depressivo Maior , Humanos , Feminino , Transtorno Depressivo Maior/diagnóstico por imagem , Transtorno Depressivo Maior/terapia , Estudos Retrospectivos , Núcleo Accumbens/diagnóstico por imagem , Estimulação Encefálica Profunda/métodos , Depressão , Imageamento por Ressonância Magnética
2.
Neuroimage ; 268: 119862, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36610682

RESUMO

Following its introduction in 2014 and with support of a broad international community, the open-source toolbox Lead-DBS has evolved into a comprehensive neuroimaging platform dedicated to localizing, reconstructing, and visualizing electrodes implanted in the human brain, in the context of deep brain stimulation (DBS) and epilepsy monitoring. Expanding clinical indications for DBS, increasing availability of related research tools, and a growing community of clinician-scientist researchers, however, have led to an ongoing need to maintain, update, and standardize the codebase of Lead-DBS. Major development efforts of the platform in recent years have now yielded an end-to-end solution for DBS-based neuroimaging analysis allowing comprehensive image preprocessing, lead localization, stimulation volume modeling, and statistical analysis within a single tool. The aim of the present manuscript is to introduce fundamental additions to the Lead-DBS pipeline including a deformation warpfield editor and novel algorithms for electrode localization. Furthermore, we introduce a total of three comprehensive tools to map DBS effects to local, tract- and brain network-levels. These updates are demonstrated using a single patient example (for subject-level analysis), as well as a retrospective cohort of 51 Parkinson's disease patients who underwent DBS of the subthalamic nucleus (for group-level analysis). Their applicability is further demonstrated by comparing the various methodological choices and the amount of explained variance in clinical outcomes across analysis streams. Finally, based on an increasing need to standardize folder and file naming specifications across research groups in neuroscience, we introduce the brain imaging data structure (BIDS) derivative standard for Lead-DBS. Thus, this multi-institutional collaborative effort represents an important stage in the evolution of a comprehensive, open-source pipeline for DBS imaging and connectomics.


Assuntos
Estimulação Encefálica Profunda , Doença de Parkinson , Núcleo Subtalâmico , Humanos , Estimulação Encefálica Profunda/métodos , Doença de Parkinson/terapia , Estudos Retrospectivos , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
3.
Hum Brain Mapp ; 44(12): 4439-4451, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37318767

RESUMO

Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is an effective treatment for advanced Parkinson's disease. Stimulation of the hyperdirect pathway (HDP) may mediate the beneficial effects, whereas stimulation of the corticospinal tract (CST) mediates capsular side effects. The study's objective was to suggest stimulation parameters based on the activation of the HDP and CST. This retrospective study included 20 Parkinson's disease patients with bilateral STN DBS. Patient-specific whole-brain probabilistic tractography was performed to extract the HDP and CST. Stimulation parameters from monopolar reviews were used to estimate volumes of tissue activated and to determine the streamlines of the pathways inside these volumes. The activated streamlines were related to the clinical observations. Two models were computed, one for the HDP to estimate effect thresholds and one for the CST to estimate capsular side effect thresholds. In a leave-one-subject-out cross-validation, the models were used to suggest stimulation parameters. The models indicated an activation of 50% of the HDP at effect threshold, and 4% of the CST at capsular side effect threshold. The suggestions for best and worst levels were significantly better than random suggestions. Finally, we compared the suggested stimulation thresholds with those from the monopolar reviews. The median suggestion errors for the effect threshold and side effect threshold were 1 and 1.5 mA, respectively. Our stimulation models of the HDP and CST suggested STN DBS settings. Prospective clinical studies are warranted to optimize tract-guided DBS programming. Together with other modalities, these may allow for assisted STN DBS programming.


Assuntos
Estimulação Encefálica Profunda , Doença de Parkinson , Núcleo Subtalâmico , Humanos , Núcleo Subtalâmico/diagnóstico por imagem , Núcleo Subtalâmico/fisiologia , Doença de Parkinson/diagnóstico por imagem , Doença de Parkinson/terapia , Tratos Piramidais/diagnóstico por imagem , Estudos Prospectivos , Estudos Retrospectivos
4.
Ann Neurol ; 91(5): 602-612, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35150172

RESUMO

OBJECTIVE: The objective of this study was to obtain individual clinical and neuroimaging data of patients undergoing deep brain stimulation (DBS) for essential tremor (ET) from 5 different European centers to identify predictors of outcome and to identify an optimal stimulation site. METHODS: We analyzed retrospectively baseline covariates, pre- and postoperative clinical tremor scores (for 12 months) as well as individual imaging data from 119 patients to obtain individual electrode positions and stimulation volumes. Individual imaging and clinical data were used to calculate a probabilistic stimulation map in normalized space using voxel-wise statistical analysis. Finally, we used this map to train a classifier to predict tremor improvement. RESULTS: Probabilistic mapping of stimulation effects yielded a statistically significant cluster that was associated with a tremor improvement >50%. This cluster of optimal stimulation extended from the posterior subthalamic area to the ventralis intermedius nucleus and coincided with a normative structural connectivity-based cerebellothalamic tract (CTT). The combined features "distance between the stimulation volume and the significant cluster" and "CTT activation" were used as a predictor of tremor improvement. This correctly classified a >50% tremor improvement with a sensitivity of 89% and a specificity of 57%. INTERPRETATION: Our multicenter ET probabilistic stimulation map identified an area of optimal stimulation along the course of the CTT. The results of this study are mainly descriptive until confirmed in independent datasets, ideally through prospective testing. This target will be made openly available and may be used to guide surgical planning and for computer-assisted programming of DBS in the future. ANN NEUROL 2022;91:602-612.


Assuntos
Estimulação Encefálica Profunda , Tremor Essencial , Estimulação Encefálica Profunda/métodos , Tremor Essencial/terapia , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento , Tremor/terapia
5.
Brain ; 143(2): 582-596, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32040563

RESUMO

Whilst exaggerated bursts of beta frequency band oscillatory synchronization in the subthalamic nucleus have been associated with motor impairment in Parkinson's disease, a plausible mechanism linking the two phenomena has been lacking. Here we test the hypothesis that increased synchronization denoted by beta bursting might compromise information coding capacity in basal ganglia networks. To this end we recorded local field potential activity in the subthalamic nucleus of 18 patients with Parkinson's disease as they executed cued upper and lower limb movements. We used the accuracy of local field potential-based classification of the limb to be moved on each trial as an index of the information held by the system with respect to intended action. Machine learning using the naïve Bayes conditional probability model was used for classification. Local field potential dynamics allowed accurate prediction of intended movements well ahead of their execution, with an area under the receiver operator characteristic curve of 0.80 ± 0.04 before imperative cues when the demanded action was known ahead of time. The presence of bursts of local field potential activity in the alpha, and even more so, in the beta frequency band significantly compromised the prediction of the limb to be moved. We conclude that low frequency bursts, particularly those in the beta band, restrict the capacity of the basal ganglia system to encode physiologically relevant information about intended actions. The current findings are also important as they suggest that local subthalamic activity may potentially be decoded to enable effector selection, in addition to force control in restorative brain-machine interface applications.


Assuntos
Extremidades/fisiopatologia , Movimento/fisiologia , Doença de Parkinson/terapia , Núcleo Subtalâmico/fisiopatologia , Potenciais de Ação/fisiologia , Gânglios da Base/fisiopatologia , Ritmo beta/fisiologia , Estimulação Encefálica Profunda/métodos , Feminino , Humanos , Masculino , Córtex Motor/fisiopatologia , Núcleo Subtalâmico/fisiologia
6.
Neuromodulation ; 24(2): 392-399, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33389771

RESUMO

BACKGROUND: Different deep brain stimulation (DBS) targets have been suggested as treatment for patients with pharmacologically refractory Holmes tremor (HT). We report the clinical and quality of life (QoL) long-term (up to nine years) outcome in four patients with HT treated with DBS (in thalamic ventral intermediate nucleus-VIM or in dentato-rubro-thalamic tract-DRTT). MATERIALS AND METHODS: The patients underwent routine clinical evaluations before and after DBS (typically annually). Tremor severity and activities of daily living (ADL) were quantified by the Fahn-Tolosa-Marin Tremor-Rating-Scale (FTMTRS). QoL was assessed using the RAND SF-36-item Health Survey (RAND SF-36). In addition, we computed, in all four patients, the VTA based on the best stimulation settings using heuristic approaches included in the open source toolbox LEAD-DBS. RESULTS: In all patients, tremor and ADL improved significantly at one-year post-DBS follow-up (34-61% improvement in FTMTRS total score compared to baseline). In three out of four patients, the improvement of tremor was sustained no longer than two to three years and only in one patient was sustained up to nine years. In this patient, the largest intersection between VTA and DBS target has been observed. Scores for ADL deteriorated over the course of time, reaching worse levels compared to baseline already during the three-year post-DBS follow-up, in three out of four patients. Physical and mental health component scores of RAND SF-36 had very different outcome between patients and follow-ups and were not associated with tremor-related outcomes. CONCLUSIONS: The benefits of DBS in HT might not be always long lasting. Although QoL slightly improved, this change seemed to be independent of the motor outcome following DBS. The estimation of DBS target and VTA proximity could be a useful tool for DBS clinicians in order to facilitate the DBS programming process and optimize DBS treatment.


Assuntos
Estimulação Encefálica Profunda , Tremor Essencial , Atividades Cotidianas , Tremor Essencial/terapia , Humanos , Neuroimagem , Qualidade de Vida , Resultado do Tratamento , Tremor/diagnóstico por imagem , Tremor/terapia
7.
Biomed Microdevices ; 16(6): 837-50, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25078417

RESUMO

Many neuroprosthetic applications require the use of very small, flexible multi-channel microelectrodes (e.g. polyimide-based film-like electrodes) to fit anatomical constraints. By arranging the electrode contacts on both sides of the polyimide film, selectivity can be further increased without increasing size. In this work, two approaches to create such double-sided electrodes are described and compared: sandwich electrodes prepared by precisely gluing two single-sided structures together, and monolithic electrodes created using a new double-sided photolithography process. Both methods were successfully applied to manufacture double-sided electrodes for stimulation of the vestibular system. In a case study, the electrodes were implanted in the semicircular canals of three guinea pigs and proven to provide electrical stimulation of the vestibular nerve. For both the monolithic electrodes and the sandwich electrodes, long-term stability and functionality was observed over a period of more than 12 months. Comparing the two types of electrodes with respect to the manufacturing process, it can be concluded that monolithic electrodes are the preferred solution for very thin electrodes (<20 µm), while sandwich electrode technology is especially suitable for thicker electrodes (40-50 µm).


Assuntos
Eletrodos Implantados , Membranas Artificiais , Desenho de Prótese , Nervo Vestibular , Animais , Estimulação Elétrica/instrumentação , Estimulação Elétrica/métodos , Cobaias , Humanos , Microeletrodos , Resinas Sintéticas/química
8.
Front Hum Neurosci ; 16: 925283, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36393984

RESUMO

Deep Brain Stimulation (DBS) is an effective treatment for advanced Parkinson's disease. However, identifying stimulation parameters, such as contact and current amplitudes, is time-consuming based on trial and error. Directional leads add more stimulation options and render this process more challenging with a higher workload for neurologists and more discomfort for patients. In this study, a sweet spot-guided algorithm was developed that automatically suggested stimulation parameters. These suggestions were retrospectively compared to clinical monopolar reviews. A cohort of 24 Parkinson's disease patients underwent bilateral DBS implantation in the subthalamic nucleus at our center. First, the DBS' leads were reconstructed with the open-source toolbox Lead-DBS. Second, a sweet spot for rigidity reduction was set as the desired stimulation target for programming. This sweet spot and estimations of the volume of tissue activated were used to suggest (i) the best lead level, (ii) the best contact, and (iii) the effect thresholds for full therapeutic effect for each contact. To assess these sweet spot-guided suggestions, the clinical monopolar reviews were considered as ground truth. In addition, the sweet spot-guided suggestions for best lead level and best contact were compared against reconstruction-guided suggestions, which considered the lead location with respect to the subthalamic nucleus. Finally, a graphical user interface was developed as an add-on to Lead-DBS and is publicly available. With the interface, suggestions for all contacts of a lead can be generated in a few seconds. The accuracy for suggesting the best out of four lead levels was 56%. These sweet spot-guided suggestions were not significantly better than reconstruction-guided suggestions (p = 0.3). The accuracy for suggesting the best out of eight contacts was 41%. These sweet spot-guided suggestions were significantly better than reconstruction-guided suggestions (p < 0.001). The sweet spot-guided suggestions of each contact's effect threshold had a mean error of 1.2 mA. On an individual lead level, the suggestions can vary more with mean errors ranging from 0.3 to 4.8 mA. Further analysis is warranted to improve the sweet spot-guided suggestions and to account for more symptoms and stimulation-induced side effects.

9.
Front Hum Neurosci ; 14: 521282, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33192384

RESUMO

Segmented deep brain stimulation leads feature directional electrodes that allow for a finer spatial control of electrical stimulation compared to traditional ring-shaped electrodes. These segmented leads have demonstrated enlarged therapeutic windows and have thus the potential to improve the treatment of Parkinson's disease patients. Moreover, they provide a unique opportunity to record directional local field potentials. Here, we investigated whether directional local field potentials can help identify the best stimulation direction to assist device programming. Four Parkinson's disease patients underwent routine implantation of the subthalamic nucleus. Firstly, local field potentials were recorded in three directions for two conditions: In one condition, the patient was at rest; in the other condition, the patient's arm was moved. Secondly, current thresholds for therapeutic and side effects were identified intraoperatively for directional stimulation. Therapeutic windows were calculated from these two thresholds. Thirdly, the spectral power of the total beta band (13-35 Hz) and its sub-bands low, high, and peak beta were analyzed post hoc. Fourthly, the spectral power was used by different algorithms to predict the ranking of directions. The spectral power profiles were patient-specific, and spectral peaks were found both in the low beta band (13-20 Hz) and in the high beta band (20.5-35 Hz). The direction with the highest spectral power in the total beta band was most indicative of the 1st best direction when defined by therapeutic window. Based on the total beta band, the resting condition and the moving condition were similarly predictive about the direction ranking and classified 83.3% of directions correctly. However, different algorithms were needed to predict the ranking defined by therapeutic window or therapeutic current threshold. Directional local field potentials may help predict the best stimulation direction. Further studies with larger sample sizes are needed to better distinguish the informative value of different conditions and the beta sub-bands.

10.
Neuroimage Clin ; 28: 102486, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33395977

RESUMO

Deep Brain Stimulation of the posterior subthalamic area is an emergent target for the treatment of Essential Tremor. Due to the heterogeneous and complex anatomy of the posterior subthalamic area, it remains unclear which specific structures mediate tremor suppression and different side effects. The objective of the current work was to yield a better understanding of what anatomical structures mediate the different clinical effects observed during directional deep brain stimulation of that area. We analysed a consecutive series of 12 essential tremor patients. Imaging analysis and systematic clinical testing performed 4-6 months postoperatively yielded location, clinical efficacy and corresponding therapeutic windows for 160 directional contacts. Overlap ratios between individual activation volumes and neighbouring thalamic and subthalamic nuclei as well as individual fiber tracts were calculated. Further, we generated stimulation heatmaps to assess the area of activity and structures stimulated during tremor suppression and occurrence of side effects. Stimulation of the dentato-rubro-thalamic tract and the zona incerta was most consistently correlated with tremor suppression. Both individual and group analysis demonstrated a similar pattern of activation for tremor suppression and different sorts of side-effects. Unlike current clinical concepts, induction of spasms and paresthesia were not correlated with stimulation of the corticospinal tract and the medial lemniscus. Furthermore, we noticed a significant difference in the therapeutic window between the best and worst directional contacts. The best directional contacts did not provide significantly larger therapeutic windows than omnidirectional stimulation at the same level. Deep brain stimulation of the posterior subthalamic area effectively suppresses all aspects of ET but can be associated with concomitant side effects limiting the therapeutic window. Activation patterns for tremor suppression and side effects were similar and predominantly involved the dentato-rubro-thalamic tract and the zona incerta. We found no different activation patterns between different types of side effects and no clear correlation between structure and function. Future studies with use of more sophisticated modelling of activation volumes taking into account fiber heterogeneity and orientation may eventually better delineate these different clusters, which may allow for a refined targeting and programming within this area.


Assuntos
Estimulação Encefálica Profunda , Tremor Essencial , Núcleo Subtalâmico , Tremor Essencial/terapia , Humanos , Relação Estrutura-Atividade , Tálamo
11.
J Neural Eng ; 17(3): 036027, 2020 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-32213673

RESUMO

OBJECTIVE: To explore the impact of different electrical stimulation profiles in human recipients of the Geneva-Maastricht vestibular implant prototypes. APPROACH: Four implanted patients were recruited for this study. We investigated the relative efficacy of systematic variations of the electrical stimulus profile (phase duration, pulse rate, baseline level, modulation depth) in evoking vestibulo-ocular (eVOR) and perceptual responses. MAIN RESULTS: Shorter phase durations and, to a lesser extent, slower pulse rates allowed maximizing the electrical dynamic range available for eliciting a wider range of intensities of vestibular percepts. When either the phase duration or the pulse rate was held constant, current modulation depth was the factor that had the most significant impact on peak velocity of the eVOR. SIGNIFICANCE: Our results identified important parametric variations that influence the measured responses. Furthermore, we observed that not all vestibular pathways seem equally sensitive to the electrical stimulus when the electrodes are placed in the semicircular canals and monopolar stimulation is used. This opens the door to evaluating new stimulation strategies for a vestibular implant, and suggests the possibility of selectively activating one vestibular pathway or the other in order to optimize rehabilitation outcomes.


Assuntos
Reflexo Vestíbulo-Ocular , Vestíbulo do Labirinto , Estimulação Elétrica , Humanos , Próteses e Implantes , Canais Semicirculares
12.
Front Neurol ; 11: 532, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32714264

RESUMO

Background: Modeling of deep brain stimulation electric fields and anatomy-based software might improve post-operative management of patients with Parkinson's disease (PD) who have benefitted from subthalamic nucleus deep brain stimulation (STN-DBS). Objective: We compared clinical and software-guided determination of the thresholds for current diffusion to the pyramidal tract, the most frequent limiting side effect in post-operative management of STN-DBS PD patients. Methods: We assessed monopolar reviews in 16 consecutive STN-DBS PD patients and retrospectively compared clinical capsular thresholds, which had been assessed according to standard clinical practice, to those predicted by volume of tissue activated (VTA) model software. All the modeling steps were performed blinded from patients' clinical evaluations. Results: At the group level, we found a significant correlation (p = 0.0001) when performing statistical analysis on the z-scored capsular thresholds, but with a low regression coefficient (r = 0.2445). When considering intra-patient analysis, we found significant correlations (p < 0.05) between capsular threshold as modeled with the software and capsular threshold as determined clinically in five patients (31.2%). Conclusions: In this pilot study, the VTA model software was of limited assistance in identifying capsular thresholds for the whole cohort due to a large inter-patient variability. Clinical testing remains the gold standard in selecting stimulation parameters for STN-DBS in PD.

13.
Brain Stimul ; 12(5): 1127-1134, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31130498

RESUMO

BACKGROUND: Directional deep brain stimulation (dDBS) of the subthalamic nucleus for Parkinson's disease (PD) increases the therapeutic window. However, empirical programming of the neurostimulator becomes more complex given the increasing number of stimulation parameters. A better understanding of dDBS is needed to improve therapy and help guide postoperative programming. OBJECTIVE: To determine whether clinical effects of dDBS can be predicted in individual patients based on lead location and volume of tissue activated (VTA) modelling. METHODS: We analysed a prospective series of 28 PD patients. Imaging analysis and systematic clinical testing performed 4-6 months postoperatively yielded location, clinical efficacy and corresponding therapeutic windows for 272 directional contacts. We calculated the corresponding VTAs to build a probabilistic stimulation map using voxel-wise statistical analysis. RESULTS: We found a positive and statistically significant correlation between the overlap ratio of a patient's individual stimulation volume and the probabilistic map's sweet spot -defined as the 10% voxels with the highest clinical efficacy values (average Spearman's rho = 0.43, average p ≤ 0.036). Patients who had a larger therapeutic window with directional compared to omnidirectional stimulation had a larger distance between the electrode and the sweet spot centroid (average distances 2.3 vs. 1.5 mm, p = 0.0019). CONCLUSION: Our analysis provides new insights into how the definition of a probabilistic sweet spot based on directional stimulation data and individual VTA modelling can be applied to predict clinically effective directional stimulation and help guide clinicians with the intricate postoperative DBS programming.


Assuntos
Mapeamento Encefálico/métodos , Estimulação Encefálica Profunda/métodos , Doença de Parkinson/terapia , Estudo de Prova de Conceito , Núcleo Subtalâmico/fisiologia , Idoso , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Resultado do Tratamento
14.
PLoS One ; 14(6): e0217985, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31216311

RESUMO

OBJECTIVE: Segmented deep brain stimulation leads in the subthalamic nucleus have shown to increase therapeutic window using directional stimulation. However, it is not fully understood how these segmented leads with reduced electrode size modify the volume of tissue activated (VTA) and how this in turn relates with clinically observed therapeutic and side effect currents. Here, we investigated the differences between directional and omnidirectional stimulation and associated VTAs with patient-specific therapeutic and side effect currents for the two stimulation modes. APPROACH: Nine patients with Parkinson's disease underwent DBS implantation in the subthalamic nucleus. Therapeutic and side effect currents were identified intraoperatively with a segmented lead using directional and omnidirectional stimulation (these current thresholds were assessed in a blinded fashion). The electric field around the lead was simulated with a finite-element model for a range of stimulation currents for both stimulation modes. VTAs were estimated from the electric field by numerical differentiation and thresholding. Then for each patient, the VTAs for given therapeutic and side effect currents were projected onto the patient-specific subthalamic nucleus and lead position. RESULTS: Stimulation with segmented leads with reduced electrode size was associated with a significant reduction of VTA and a significant increase of radial distance in the best direction of stimulation. While beneficial effects were associated with activation volumes confined within the anatomical boundaries of the subthalamic nucleus at therapeutic currents, side effects were associated with activation volumes spreading beyond the nucleus' boundaries. SIGNIFICANCE: The clinical benefits of segmented leads are likely to be obtained by a VTA confined within the subthalamic nucleus and a larger radial distance in the best stimulation direction, while steering the VTA away from unwanted fiber tracts outside the nucleus. Applying the same concepts at a larger scale and in chronically implanted patients may help to predict the best stimulation area.


Assuntos
Estimulação Encefálica Profunda/métodos , Doença de Parkinson/terapia , Núcleo Subtalâmico/efeitos da radiação , Adulto , Idoso , Sistema Nervoso Central/fisiopatologia , Sistema Nervoso Central/efeitos da radiação , Estimulação Encefálica Profunda/efeitos adversos , Estimulação Elétrica , Eletrodos Implantados , Campos Eletromagnéticos/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Contração Muscular/efeitos da radiação , Doença de Parkinson/fisiopatologia , Núcleo Subtalâmico/fisiopatologia
15.
Front Syst Neurosci ; 8: 255, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25653601

RESUMO

The vestibulo-ocular reflex (VOR) shows frequency-dependent behavior. This study investigated whether the characteristics of the electrically evoked VOR (eVOR) elicited by a vestibular implant, showed the same frequency-dependency. Twelve vestibular electrodes implanted in seven patients with bilateral vestibular hypofunction (BVH) were tested. Stimuli consisted of amplitude-modulated electrical stimulation with a sinusoidal profile at frequencies of 0.5, 1, and 2 Hz. The main characteristics of the eVOR were evaluated and compared to the "natural" VOR characteristics measured in a group of age-matched healthy volunteers who were subjected to horizontal whole body rotations with equivalent sinusoidal velocity profiles at the same frequencies. A strong and significant effect of frequency was observed in the total peak eye velocity of the eVOR. This effect was similar to that observed in the "natural" VOR. Other characteristics of the (e)VOR (angle, habituation-index, and asymmetry) showed no significant frequency-dependent effect. In conclusion, this study demonstrates that, at least at the specific (limited) frequency range tested, responses elicited by a vestibular implant closely mimic the frequency-dependency of the "normal" vestibular system.

16.
IEEE Trans Biomed Circuits Syst ; 8(4): 474-84, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25073124

RESUMO

Researchers have succeeded in partly restoring damaged vestibular functionality in several animal models. Recently, acute interventions have also been demonstrated in human patients. Our previous work on a vestibular implant for humans used predefined stimulation patterns; here we present a research tool that facilitates motion-modulated stimulation. This requires a system that can process gyroscope measurements and send stimulation parameters to a hybrid vestibular-cochlear implant in real-time. To match natural vestibular latencies, the time from sensor input to stimulation output should not exceed 6.5 ms. We describe a system based on National Instrument's CompactRIO platform that can meet this requirement and also offers floating point precision for advanced transfer functions. It is designed for acute clinical interventions, and is sufficiently powerful and flexible to serve as a development platform for evaluating prosthetic control strategies. Amplitude and pulse frequency modulation to predetermined functions or sensor inputs have been validated. The system has been connected to human patients, who each have received a modified MED-EL cochlear implant for vestibular stimulation, and patient tests are ongoing.


Assuntos
Implantes Cocleares , Doenças Vestibulares/terapia , Humanos , Sistemas Microeletromecânicos , Pesquisa , Software , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA