1.
J Arthroplasty ; 2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38679349

RESUMO

BACKGROUND: Sterile surgical helmet systems are frequently utilized in total knee arthroplasty procedures to protect the surgeon while maintaining a comfortable working environment. However, common helmet systems pressurize the space between the surgical gown and the surgeon's skin. In gowns with a back seam, this may allow contaminated skin particles to escape into the surgical field. By measuring bacterial colony-forming units (CFUs), this study sought to determine if occlusion of the open back seam reduced the risk of potential contamination. METHODS: First, qualitative analysis depicting airflow variations between gown configurations was performed using the Schlieren Spherical Mirror imaging system. Each gown configuration consisted of a sterile surgical helmet and one of 3 gown configurations: a standard gown with rear-tied closure, a standard gown with a surgical vest, and a zippered Toga-style gown. Next, a surgeon then performed simulated surgical activities for 60 minutes within a 1.4 m3 isolation chamber with work surfaces and controllable filtered air exchanges. During each procedure, contaminated particles were collected on sets of agar settle plates positioned directly behind the surgeon. Upon completion, the agar plates were incubated in a biolab, and the number of bacterial and fungal CFUs was counted. The experimental procedure was repeated 12 times for each gown configuration, with sterilization of the chamber between runs. Contamination rates were expressed as CFUs/m2/h. RESULTS: The mean contamination rate measured with the standard gown was 331.7 ± 52.0 CFU/m2/h. After the addition of a surgical vest, this rate decreased by 45% to 182.2 ± 30.8 CFU/m2/h (P = .02). Similarly, with the Toga-style gown, contamination rates dropped by 49% to 170.5 ± 41.9 CFU/m2/h (P = .01). CONCLUSIONS: When used in conjunction with surgical helmet systems, conventional surgical gowns do not prevent potential contamination of the surgical field. We recommend that staff within the surgical field cover the back seam of standard gowns with a vest or don a zippered Toga-style gown.

2.
J Arthroplasty ; 2023 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-38072096

RESUMO

BACKGROUND: The morphology of the trochlear compartment of total knee arthroplasty (TKA) prostheses is a major determinant of postoperative patello-femoral kinematics, particularly with unresurfaced patellae. The objective of this study was to quantify and compare the trochlear morphology of a large series of contemporary and legacy TKA designs. METHODS: The 3-dimensional surface models of 22 femoral components (13 contemporary and 9 legacy) were created using high-resolution laser scanning. The trochlear profile of each component was analyzed from proximal to distal in 15° increments around the trochlear axis. In each profile, the following variables were measured: sulcus angle, medio-lateral deviation of the sulcus, the height and width of the facets, and the trochlear groove orientation. RESULTS: In the contemporary group, the sulcus angle decreased progressively along the trochlear arc to varying degrees, except for 2 symmetrical designs, whereas the sulcus angle of the legacy designs showed considerable variability. The height of the medial facet was very strongly correlated with that of the lateral facet in the contemporary group (R2 = 0.89), whereas the correlation was weak for the legacy designs (R2 = 0.36). Moreover, the trochlear sulcus deviated laterally from distal to proximal in 10 contemporary designs and 7 legacy designs, resulting in a trochlear groove orientation of 4.2 to 11.1° and 4.3 to 10.5°, respectively. In the remaining 5 designs (3 contemporary and 2 legacy), the sulcus was vertical. CONCLUSIONS: There is more consistency in trochlear morphology of contemporary TKA designs compared to that of legacy designs, yet there are still large variations between different designs.

3.
J Arthroplasty ; 38(7S): S292-S297, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36933680

RESUMO

BACKGROUND: Due to increasing volume of total hip arthroplasties, periprosthetic femoral fractures have become a common complication with increased revision burden and perioperative morbidity. The objective of this study was to evaluate the fixation stability of Vancouver B2 fractures treated with 2 techniques. METHODS: A common B2 fracture was created by reviewing 30 type B2 cases. The fracture was then reproduced in 7 pairs of cadaveric femora. The specimens were divided into 2 groups. In Group I ("reduce-first"), the fragments were reduced first, followed by implantation of a tapered fluted stem. In Group II ("ream-first"), the stem was implanted in the distal femur first, followed by fragment reduction and fixation. Each specimen was loaded in a multiaxial testing frame with 70% of peak load during walking. A motion capture system was used to track the motion of the stem and fragments. RESULTS: The average stem diameter in Group II was 16.1 ± 0.4 mm, versus 15.4 ± 0.5 mm in Group I. The fixation stability was not significantly different in the 2 groups. After the testing, the average stem subsidence was 0.36 ± 0.31 mm and 0.19 ± 0.14 mm (P = .17) and the average rotation was 1.67 ± 1.30° and 0.91 ± 1.11° (P = .16) in Groups I and II, respectively. Compared to the stem, there was less motion of the fragments and there was no difference between the 2 groups (P > .05). CONCLUSIONS: When tapered fluted stems were used in combination with cerclage cables for treatment of Vancouver type B2 periprosthetic femoral fractures, both the "reduce-first" and "ream-first" techniques showed adequate stem and fracture stability.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Prótese de Quadril/efeitos adversos , Reoperação/efeitos adversos , Resultado do Tratamento , Artroplastia de Quadril/efeitos adversos , Fraturas Periprotéticas/cirurgia , Fraturas Periprotéticas/complicações , Fêmur/cirurgia , Fraturas do Fêmur/etiologia , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Estudos Retrospectivos
4.
J Arthroplasty ; 37(7S): S697-S702, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35307531

RESUMO

BACKGROUND: Diaphyseal fixation remains the mainstay of revision THA. The stability of diaphyseal fixation can be quantified by the extent of contact between the stem and the endosteal cortex. This is highly affected by the morphology of the proximal femur. The purpose of this study was to examine factors affecting diaphyseal contact in the revision THA and to identify preoperative predictors of adequate fixation. METHODS: Three-dimensional femur models were created from CT scans of 33 Dorr B and C femora. The proximal 120 mm of the femur was omitted to mimic proximal bone deficiency. A tapered fluted stem (3 degrees, 150 mm) model was virtually implanted after reaming of the medullary canal. The contact length between stem and endosteal cortex was measured, in addition to other variables. The relationship between variables was evaluated using Spearman's correlation, and logistic regression analysis was used to identify predictors of the contact length (P < .05). RESULTS: The contact length varied widely between specimens (66.5 ± 16.6 mm, range: 21-98 mm). Contact increased with the depth of the isthmus below the lesser trochanter (range: 55-155 mm; r2 = 0.473, P = .005) and the distance between the isthmus and the distal edge of the damage zone (range: -9 to 96 mm; r2 = 0.508, P = .002). Stepwise regression identified the reaming length, distance between fracture and the isthmus, and isthmus diameter as independent predictors of contact length (r = 0.643). CONCLUSIONS: Contact is limited in specimens where the isthmus is more proximally located. In these cases, supplementary fixation using plating and/or longer, curved prosthesis may be considered.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/métodos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Desenho de Prótese , Reoperação/métodos , Estudos Retrospectivos
5.
J Arthroplasty ; 37(6S): S301-S305, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35219817

RESUMO

BACKGROUND: Prosthetic joint infections have become the leading cause of joint replacement failure. The primary sources of contamination are skin flora and bacteria from airborne particles. Portable ultraviolet air disinfection units are used in the Operating Room (OR) to prevent contamination from airborne particles; however, their effectiveness is not proven. The purpose of this study was to compare the rate of contamination of sites with and without Ultraviolet (UV) air disinfection units during active surgeries. METHODS: Sedimentation rates of viable particles were measured during 40 primary TKA procedures. Half of the procedures were performed with ultraviolet air disinfection units. Air-borne particles were collected on nitrocellulose membranes at 5 locations within the OR. After incubation, all microbial colonies were counted and the sedimentation rates were reported in CFUs/m2/hr. 10 additional trials were performed in an empty OR with no staff present. RESULTS: The average contamination rate of all sites was 22 ± 1.1 CFUs/m2/hr in the empty OR vs. 21.3 ± 4.6 CFUs/m2/hr with UV units and 20.3 ± 4.9 CFUs/m2/hr without (P = .03, P = .03, P = .964). Viable contaminates were found in the sterile field in 25% of UV cases vs 45% non-UV. These differences were not statistically significant. There were differences found however, according to the number of staff in the room (6 vs 7 staff: P = .036, 6 vs 8 staff: P = .004). CONCLUSION: There was no statistical difference in contamination rate with the usage or non-usage of UV units. These 40 cases shows that the largest variables affecting the contamination rate were the number of staff present and size of the OR.


Assuntos
Artroplastia do Joelho , Desinfecção , Microbiologia do Ar , Bactérias , Desinfecção/métodos , Humanos , Salas Cirúrgicas , Raios Ultravioleta
6.
J Arthroplasty ; 36(1): 349-355, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32741712

RESUMO

BACKGROUND: The outcome of cementless total knee arthroplasty (TKA) relies on successful bony ingrowth into the implant surfaces. Failures due to aseptic loosening are still reported, especially in younger and more active patients. The objective of this study is to quantify the micromotion of a commercially available design of cementless tibial tray under loading conditions simulating walking and stair descent. METHOD: A commercially available design of cementless total knee arthroplasty was implanted in 7 cadaveric knees which were preconditioned with 500 cycles of 0°-100° flexion under a vertical load of 1050 N in a custom-built, multiaxial functional activity simulator. This was followed by application of the peak forces and moments occurring during walking and stair descent. During each loading procedure, 3-dimensional motion at the bone-prosthesis interface was measured using digital image correlation. RESULTS: The tray migrated 101 ± 25 µm on average during preconditioning, which was dominated by rotation in the sagittal plane (92% of total migration), combined with posterior translation (28%) and minimal rotation in the transverse plane (14%). The migration varied 2.7-fold (61-167 µm) between the 6 measurement zones. Stair descent produced significantly higher total micromotion than walking in zone #5 (62 ± 9 vs 51 ± 10 µm, P < .05) and zone #6 (68 ± 17 vs 37 ± 10 µm, P < .05). In addition, during stair descent, the tray exhibited significantly more tilting (anterior zones: 31 ± 17 vs -16 ± 20 µm, P < .05; posterior zones: -60 ± 8 vs -40 ± 7 µm, P < .05) and more anteroposterior displacement in the anterior zones (-25 ± 3 vs -13 ± 2 µm, P < .05) when compared to walking. CONCLUSION: The relative motion at the bone-prosthesis interface varied substantially around the periphery of the cementless tray. Under the loading conditions evaluated, the tray primarily underwent a rocking motion in the sagittal plane. Compared with walking, stair descent produced significantly more micromotion, especially in the posterior zones.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Desenho de Prótese , Amplitude de Movimento Articular , Tíbia/cirurgia , Caminhada
7.
J Arthroplasty ; 35(3): 870-876, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31694778

RESUMO

BACKGROUND: Cementless total knee arthroplasty has been developed to decrease the incidence of failure in younger and more active patients. However, failures are still more common in cementless versus cemented components. It is hypothesized that this is triggered by incomplete bone-tray contact. The present study compares the final contact area of a cementless tray as a function of the initial osteotomy flatness. METHODS: Eight surgeons prepared 14 cadaveric knees for cementless total knee replacement using standard instrumentation. The topography of each osteotomy was captured with a laser scanner; 3-dimensional computer models of the surfaces were generated. After scanning each tibia, the surgeons implanted cementless tibial trays using a manual impactor. Each tibia was then dissected, embedded in mounting resin, and sectioned. The sectioned blocks were observed under stereomicroscopy to identify points of bone-tray contact which were incorporated into the 3-dimensional models. Maps were then generated illustrating depicting contacting and noncontacting areas. RESULTS: The mean initial flatness of all specimens was 1.1 ± 0.35 mm. After impaction, 79.4% ± 0.3% of the surface had established bony contact. Of the noncontacting areas, 17.6% were within 0.3 mm of the tray. Only 2.6% of the surface was at distances reported to impede ingrowth. Noncontacting areas were typically located centrally. A trend in decreasing percent contact area with increased flatness tolerance was observed (R2 = 0.605). CONCLUSION: (1) There is an inverse correlation between the flatness of the tibial osteotomy and the percentage of the bony surface in contact with underside of the tibial tray. (2) Almost all tray-tibia contact is generated during implantation through flattening of elevated features on the tibial surface. (3) Gaps between the tray and the tibia are consistently located in the central regions of the osteotomy proximal to the medullary canal.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Articulação do Joelho/cirurgia , Osteotomia , Tíbia/cirurgia
8.
J Hand Surg Am ; 44(2): 156.e1-156.e8, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29891271

RESUMO

PURPOSE: To evaluate the impact of suture caliber and looped configurations on the integrity of 4-strand modified Kessler zone II flexor tendon repairs during progressive cyclic loading. METHODS: Seventy-two flexor digitorum profundus tendons from 18 fresh human cadaver hands were divided into 4 repair groups. Thirty-six matched tendons underwent repair using either a 4-0 looped or 4-0 single-stranded suture, and an additional 36 tendons underwent 3-0 looped or 3-0 single-stranded repairs. Repair strength was tested by progressive cyclic loading. The force generating 2-mm gap formation, ultimate failure, and the mechanism of failure were recorded for each test. The impact of looped versus single-stranded configurations and the effect of tendon cross-sectional area on repair integrity were analyzed for each suture caliber. RESULTS: There was no statistically significant difference between groups regarding the force to 2-mm gap formation or ultimate failure, and all values exceeded the minimum threshold of 27 N required to withstand an early active range of motion rehabilitation protocol. The use of a 3-0 caliber suture resulted in a significantly higher proportion of repairs failing by suture pullout through the tendon substance, including 63.5% of looped and 38.9% of single-stranded core sutures. By comparison, this occurred in 11.1% of 4-0 looped and 0% of 4-0 single-stranded sutures. Larger tendon cross-sectional areas were associated with more robust repairs, particularly in the 3-0 looped group. CONCLUSIONS: In a human cadaver flexor tendon repair model, there was no significant difference in the mean force to failure between all 4 flexor tendon repair constructs under progressive cyclic loading. However, the 3-0 caliber suture failed more frequently by suture pullout, particularly with the use of a looped suture. CLINICAL RELEVANCE: Four-strand flexor tendon repairs using a 3-0 caliber suture are more prone to early failure by suture pullout under progressive cyclic loading compared with a 4-0 caliber suture.


Assuntos
Traumatismos dos Dedos/cirurgia , Técnicas de Sutura , Suturas , Traumatismos dos Tendões/cirurgia , Fenômenos Biomecânicos , Cadáver , Humanos , Estresse Mecânico , Resistência à Tração
9.
J Arthroplasty ; 33(4): 1012-1018, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29195854

RESUMO

BACKGROUND: Total joint patients are particularly vulnerable to perioperative hypothermia (PH) (combined effects of anesthesia, radiation, and convective heat loss from exposed skin surfaces and cool temperatures in the operating room). There are limited studies on PH in these patients. METHODS: In a retrospective review of 204 patients undergoing primary hip and 179 undergoing primary knee replacement surgeries, time and temperature parameters were collected from the electronic health records from preoperative and postoperative recovery room nursing assessments, intraoperative anesthesia records, and floor nursing notes. Basic patient demographic data was recorded. Chi-squared and paired t-tests were used to compare between hypothermic and normothermic groups. RESULTS: At the time of incision, 60 of 179 (34%) total knee arthroplasty (TKA) patients and 80 of 204 (39%) total hip arthroplasty (THA) patients were hypothermic. In THA patients, 65% remained hypothermic for the duration of anesthesia compared to 33% of TKA patients. The largest drop in core body temperature in both THA and TKA patients occurred between preoperative holding and induction of anesthesia. In THA patients, spinal anesthesia had a significantly higher occurrence of PH. No significant patient factor was found to increase risk. CONCLUSION: Emphasis on preoperative holding protocols, decreasing time from operating room entry to incision, and increasing ambient room temperature could reduce risk of hypothermia in total joint replacement patients.


Assuntos
Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Hipotermia/etiologia , Idoso , Anestesia , Temperatura Baixa , Registros Eletrônicos de Saúde , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Salas Cirúrgicas , Período Pós-Operatório , Estudos Retrospectivos , Risco
10.
J Orthop Sci ; 23(2): 310-315, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29274738

RESUMO

BACKGROUND: Accurate measurements of shoulder and elbow motion are required for the management of musculoskeletal pathology. The purpose of this investigation was to compare three techniques for measuring motion. The authors hypothesized that digital photography would be equivalent in accuracy and show higher precision compared to the other two techniques. METHODS: Using infrared motion capture analysis as the reference standard, shoulder flexion/abduction/internal rotation/external rotation and elbow flexion/extension were measured using visual estimation, goniometry, and digital photography on 10 fresh frozen cadavers. These measurements were performed by three physical therapists and three orthopaedic surgeons. Accuracy was defined by the difference from the reference standard (motion capture analysis), while precision was defined by the proportion of measurements within the authors' definition of clinical significance (10° for all motions except for elbow extension where 5° was used). Analysis of variance (ANOVA), t-tests, and chi-squared tests were used. RESULTS: Although statistically significant differences were found in measurement accuracy between the three techniques, none of these differences met the authors' definition of clinical significance. Precision of the measurements was significantly higher for both digital photography (shoulder abduction [93% vs. 74%, p < 0.001], shoulder internal rotation [97% vs. 83%, p = 0.001], and elbow flexion [93% vs. 65%, p < 0.001]) and goniometry (shoulder abduction [92% vs. 74%, p < 0.001] and shoulder internal rotation [94% vs. 83%, p = 0.008]) than visual estimation. Digital photography was more precise than goniometry for measurements of elbow flexion only [93% vs. 76%, p < 0.001]. CONCLUSIONS: There was no clinically significant difference in measurement accuracy between the three techniques for shoulder and elbow motion. Digital photography showed higher measurement precision compared to visual estimation for shoulder abduction, shoulder internal rotation, and elbow flexion. However, digital photography was only more precise than goniometry for measurements of elbow flexion. Overall digital photography shows equivalent accuracy to visual estimation and goniometry, but with higher precision than visual estimation.


Assuntos
Artrometria Articular/métodos , Articulação do Cotovelo/fisiologia , Fotografação/métodos , Amplitude de Movimento Articular/fisiologia , Articulação do Ombro/fisiologia , Cadáver , Humanos , Masculino , Sensibilidade e Especificidade
11.
J Arthroplasty ; 32(4): 1356-1359, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27836578

RESUMO

BACKGROUND: Metal wear and corrosion from modular junctions in total hip arthroplasty can lead to further unwanted surgery. Trunnion tribocorrosion is recognized as an important contributor to failure. This study was performed to determine if new metal heads restore mechanical integrity of the original modular junction after impaction on corroded trunnions, and assess which variables affect stability of the new interface created at revision total hip arthroplasty. METHODS: Twenty-two trunnions, cobalt-chromium (CoCr) and titanium alloy (TiAIV), (CoCr, n = 12; TiAIV, n = 10) and new metal heads were used, 10 trunnions in pristine condition and 12 with corrosion damage. Test states were performed using an MTS Machine and included the following: 1, Assembly; 2, Disassembly; 3, Assembly; 4, Toggling; and 5, Disassembly. During loading, three-dimensional motion of the head-trunnion junction was measured using a custom jig. RESULTS: There were no statistical differences in the tested mechanical properties between corroded and pristine trunnions implanted with a new metal femoral head. Average micromotion of the head versus trunnion interface was greatest at the start of loading, stabilizing after approximately 50 loading cycles at an average of 30.6 ± 3.2 µm. CONCLUSION: Corrosion at the trunnion does not disrupt mechanical integrity of the junction when a CoCr head is replaced with a CoCr trunnion. However, increased interface motion of a new metal head on a corroded titanium trunnion requires additional study. The evaluation of ball head size on mechanical integrity of trunnions would also be a potential subject of future investigation, as increasing the ball head size at the time of revision is not uncommon in revisions today.


Assuntos
Prótese de Quadril , Falha de Prótese , Ligas , Artroplastia de Quadril/instrumentação , Cromo , Ligas de Cromo , Cobalto , Corrosão , Cabeça do Fêmur/cirurgia , Humanos , Metais , Desenho de Prótese , Titânio
12.
J Arthroplasty ; 32(2): 587-593, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27612608

RESUMO

BACKGROUND: In cases of femoral neck fracture, it is often not possible to accurately determine the original position of the head center to assess appropriate restoration of leg length. The aim of this study was to determine the accuracy of predicting the position of the femoral head center based on new and established correlations between the femoral head diameter (FHD) and the distance between the lesser trochanter and the femoral head center (LT-FHC) in the very elderly (aged ≥80 years) as the mainly affected but yet underinvestigated group. METHODS: The FHD and the LT-FHC distance were determined in 148 subjects (104 males, 44 females); 90 aged ≥80 years and 58 aged <80 years. For each age and gender subgroup one specific (LT-FHC)/FHD ratio was determined. The accuracy of the new determined ratios and the established ratios by others were compared by recalculating the LT-FHC distance of each individual subject. RESULTS: The FHD and the LT-FHC were significantly correlated, most strongly in elderly females (R = 0.554, P < .001). Using the new age- and gender-specific ratios, the LT-FHC distance could be predicted within 10 mm of the true value in 95% of the cases and in only 77% using previously reported formulas. CONCLUSION: Age- and gender-specific formulas yield higher accuracy than generic formulas. The formulas presented in this study can offer a practical, easy to use instrument for orthopedic surgeons performing hip arthroplasty in very elderly patients in addition to classic techniques to prevent significant leg-length discrepancy.


Assuntos
Cabeça do Fêmur/anatomia & histologia , Articulação do Quadril/anatomia & histologia , Modelos Estatísticos , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Pontos de Referência Anatômicos , Artroplastia de Substituição , Artroplastia de Quadril , Feminino , Fraturas do Colo Femoral , Fêmur , Humanos , Desigualdade de Membros Inferiores , Masculino , Pessoa de Meia-Idade
13.
J Arthroplasty ; 32(2): 581-586, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27546472

RESUMO

BACKGROUND: Accurate reconstruction of hip joint biomechanics is the key stone in total hip arthroplasty. Although proximal femur morphology is known to vary with both age and gender, few studies investigated this in the very elderly (ie, ≥80 years). The purpose of this study was to compare basic morphological parameters describing the position of the femoral head between very elderly and middle-aged subjects. METHODS: Computed tomographic scans of the femur of 90 very elderly (mean 84 years, range 80-105 years) and 58 middle-aged subjects (mean 52 years, range 20-79 years) were made. After 3-dimensional reconstruction, the neck-shaft angle, femoral neck anteversion angle, femoral head height, femoral neck length, and mediolateral offset (ML-offset) were determined. RESULTS: The neck-shaft angle was on average 3.6° less in elderly males (125.9° ± 5.0°) than in middle-aged males (129.5° ± 5.1°) (P < .001). The femoral neck anteversion angle was not significantly different between both age and gender groups. The femoral head height was -12.3 mm in elderly females compared to -10.5 mm (Δ 17%) in elderly males (P = .284) and even -8.0 mm (Δ 54%) in middle-aged males. The ML-offset was 10% (4.1 mm) larger in elderly compared to middle-aged males (P < .001). CONCLUSION: These findings suggest that the femoral neck and head shift in a relative varus position during aging. Femoral prostheses with increased ML-offset and a lower caput-collum-diaphyseal angle are needed to accommodate the morphology of the femur in the very elderly. Care must be taken not to lengthen the operated leg, particularly in very elderly females.


Assuntos
Envelhecimento/patologia , Cabeça do Fêmur/patologia , Colo do Fêmur/patologia , Articulação do Quadril/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril , Feminino , Fêmur/cirurgia , Cabeça do Fêmur/diagnóstico por imagem , Cabeça do Fêmur/cirurgia , Colo do Fêmur/diagnóstico por imagem , Colo do Fêmur/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Próteses e Implantes , Tomografia Computadorizada por Raios X , Adulto Jovem
14.
Clin Orthop Relat Res ; 474(1): 134-42, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26047645

RESUMO

BACKGROUND: The patient's own evaluation of function and satisfaction is a fundamental component of assessing outcomes after total knee arthroplasty (TKA). The new Knee Society Knee Score was introduced in 2012 and has been shown to be a valid and reliable instrument for measuring the outcome of TKA. This score combines an objective, physician-derived component and a patient-reported component to characterize the expectations, satisfaction, and functional activities of diverse lifestyles of contemporary patients undergoing TKA. However, in the routine clinical setting, the administration and scoring of outcome measures is often resource-intensive, as the expenditure of time and budget for outcome measurement increase with the length and complexity of the instrument used, and so a short-form assessment can help to reduce the burden the assessment of outcomes. QUESTIONS/PURPOSES: The purposes of this study were (1) to develop a short-form version of the new Knee Society Knee Score; (2) to validate the short form against the full Knee Society Knee Score; and (3) to evaluate the responsiveness to treatment (TKA) of the new Knee Society short-form assessment. METHODS: To develop the short form, data from the sample of 497 patients recruited during validation of the original long form the new Knee Society Knee Score were used. The multicenter study was approved by the institutional review boards at 15 participating medical institutions within the United States and Canada. An analytic item reduction approach was applied simultaneously but separately to preoperative and postoperative patient-reported data to select a subset of items from the original form that had good measurement properties and closely reflected the scores obtained using the original form. RESULTS: Expectations and satisfaction were reflected by a single item in the newly developed short form compared with a total of five satisfaction and three expectation items in the long form. The functional activities subscale was reduced from 17 to six items. An excellent correlation was demonstrated between function scores derived from the functional activities subscale of the original long-form score (17 items) and the six-item short form (r = 0.97; p < 0.01). The sample mean difference between the two scores was less than 4 points with a SD of 6.7 points. The short form was capable of discriminating clinically different groups of patients before and after TKA with virtually the same estimated effect size as the original functional activities subscale of the new Knee Society Knee Score. CONCLUSIONS: The Knee Society Knee Score long form is still recommended for research studies and for more sensitive measurement of the outcomes of individual patients. However, for general clinical use with large patient populations, the short form is expected to improve the rate of patient completion while also being easier to administer. In this study, we found the short-form version of the Knee Society Knee Score to be practical, valid, reliable, and responsive for assessing the functional outcome of TKA.


Assuntos
Artroplastia do Joelho , Articulação do Joelho/cirurgia , Satisfação do Paciente , Inquéritos e Questionários , Atividades Cotidianas , Idoso , Artroplastia do Joelho/efeitos adversos , Fenômenos Biomecânicos , Feminino , Humanos , Articulação do Joelho/fisiopatologia , Masculino , Qualidade de Vida , Recuperação de Função Fisiológica , Reprodutibilidade dos Testes , Resultado do Tratamento
15.
Arthroscopy ; 32(8): 1624-30, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27056289

RESUMO

PURPOSE: To identify desired minimum depth setting for safe, effective placement of the all-inside meniscal suture anchors. METHODS: Using 16 cadaveric knees and standard arthroscopic techniques, 3-dimensional surfaces of the meniscocapsular junction and posterior capsule were digitized. Using standard anteromedial and anterolateral portals, the distance from the meniscocapsular junction to the posterior capsule outer wall was measured for 3 locations along the posterior half of medial and lateral menisci. Multiple all-inside meniscal repairs were performed on 7 knees to determine an alternate measure of capsular thickness (X2) and compared with the digitized results. RESULTS: In the digitized group, the distance (X1) from the capsular junction to the posterior capsular wall was averaged in both menisci for 3 regions using anteromedial and anterolateral portals. Mean distances of 6.4 to 8.8 mm were found for the lateral meniscus and 6.5 to 9.1 mm for the medial meniscus. The actual penetration depth was determined in the repair group and labeled X2. It showed a similar pattern to the variation seen in X1 by region, although it exceeded predicted distances an average 1.7 mm in the medial and 1.5 mm in the lateral meniscus owing to visible deformation of the capsule as it pierced. CONCLUSIONS: Capsular thickness during arthroscopic repair measures approximately 6 to 9 mm (X1), with 1.5 to 2 mm additional depth needed to ensure penetration rather than bulging of the posterior capsule (X2), resulting in 8 to 10 mm minimum penetration depth range. Surgeons can add desired distance away from the meniscocapsular junction (L) at device implantation, finding optimal minimal setting for penetration depth (X2 + L), which for most repairable tears may be as short as 8 mm and not likely to be greater than 16 mm. CLINICAL RELEVANCE: Minimum depth setting for optimal placement of all-inside meniscal suture anchors when performing all-inside repair of the medial or lateral meniscus reduces risk of harming adjacent structures secondary to overpenetration and underpenetration of the posterior capsule.


Assuntos
Artroscopia/métodos , Articulação do Joelho/cirurgia , Meniscos Tibiais/cirurgia , Adulto , Cadáver , Humanos , Pessoa de Meia-Idade , Âncoras de Sutura , Técnicas de Sutura/instrumentação , Cicatrização , Adulto Jovem
16.
J Arthroplasty ; 31(9 Suppl): 59-62, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27262420

RESUMO

BACKGROUND: The objectives of this study were to quantify increased utilization of resources in revision total knee arthroplasty (TKA) compared with primary TKA, determine preoperative factors that predict outcome measures, and compare Medicare reimbursement for each procedure. METHODS: Seventy-eight revision TKA patients were compared with 80 primary TKA patients. Outcomes measured were surgical time, estimated blood loss, length of stay, and complications. RESULTS: Revision TKA showed 49% increased surgical time compared with primary TKA. Estimated blood loss was increased 91%. Tibial and femoral bone loss was associated with increased surgical time as was use of longer stemmed tibial components. Average Medicare hospital payment increased 29% ($13,464 for primary, $17,331 for revision). Average physician reimbursement represented a 36% increase. Relative value units were increased to 31%. CONCLUSION: There was substantial increase in work effort not commensurate with current Medicare reimbursement, which may limit patient access to revision TKA.


Assuntos
Artroplastia do Joelho/métodos , Duração da Cirurgia , Reoperação/métodos , Cirurgiões , Idoso , Artroplastia do Joelho/efeitos adversos , Feminino , Custos de Cuidados de Saúde , Recursos em Saúde , Hospitais , Humanos , Tempo de Internação , Masculino , Medicare , Pessoa de Meia-Idade , Mecanismo de Reembolso , Tíbia , Estados Unidos
17.
J Arthroplasty ; 31(6): 1188-1193, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26777577

RESUMO

BACKGROUND: Primary total hip arthroplasties (THAs) performed annually are projected to increase 174% by 2030, causing a parallel increase for revision THA. Increased surgical effort and readmission rates associated with revision THA may discourage surgeons from performing them. Although revision THA Medicare reimbursement is greater, it may be disproportionate to time and effort. We examined work input between primary and revision THA, assessing predictive factors. We also compared surgeon work input to current reimbursement. METHODS: A total of 156 patients were identified, 80 primary and 76 revision THA. Demographic, clinical, and radiographic data were collected. Radiographic data were collected from the most recent preoperative radiographs taken before primary or revision THA. Multiple linear and logistic regression models were used to identify patient factors contributing to select outcome variables by a stepwise method, with a probability value for entry (P = .05) and removal (P = .10). Residual analysis was performed, confirming validity of these models. RESULTS: Average age, body mass index, and percentage of female patients were similar between cohorts. There was no statistically significant difference between the demographic variables, although data revealed patient variables contributing to statistically significant increases in surgical time, length of stay, blood loss, and complications with revision THA. CONCLUSION: Despite a 66% increase in "percent effort" and 3-fold higher readmission rate, revision THA requires at least a 2-fold increase because of nonquantifiable factors. Revision THA demonstrates a substantial increase in work effort not commensurate with current Medicare reimbursement, which may force surgeons to limit or eliminate revision arthroplasties performed reducing access to patient care.


Assuntos
Artroplastia de Quadril/métodos , Reoperação/métodos , Cirurgiões , Idoso , Artroplastia de Quadril/economia , Artroplastia de Quadril/estatística & dados numéricos , Estudos de Coortes , Feminino , Acessibilidade aos Serviços de Saúde , Humanos , Masculino , Medicare , Pessoa de Meia-Idade , Duração da Cirurgia , Readmissão do Paciente/economia , Readmissão do Paciente/legislação & jurisprudência , Readmissão do Paciente/estatística & dados numéricos , Mecanismo de Reembolso , Reoperação/economia , Reoperação/estatística & dados numéricos , Resultado do Tratamento , Estados Unidos
18.
Clin Orthop Relat Res ; 473(2): 602-7, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24989124

RESUMO

BACKGROUND: Experimental disruption of the labrum has been shown to compromise its sealing function and alter cartilage lubrication. However, it is not known whether pathological changes to the labrum secondary to femoroacetabular impingement (FAI) have a similar impact on labral function. QUESTIONS/PURPOSES: Does damage to the labrum occurring in association with abnormal femoral morphology affect the labral seal? METHODS: Using 10 fresh cadaveric specimens (mean age 50 years, ±8), we measured the capacity of the central compartment of the hip (the iliofemoral joint) to maintain a seal during fluid infusion, which may help elucidate the function of the labrum during weightbearing. Specimens with and without abnormal femoral morphology (six normal-appearing specimens and four whose geometry suggested cam-type FAI) were tested in postures observed during functional activities, including simulations of normal gait, stooping, and pivoting. Each specimen with FAI morphology exhibited secondary damage of the labrum and the adjacent chondral surface, whereas specimens of normal morphology were undamaged. RESULTS: Average peak central compartment pressure was reduced during pivoting for specimens with the presence of labral damage secondary to FAI. When placed in pivoting positions, hips with FAI maintained lower fluid pressures within the central compartment compared with intact specimens (15±3 versus 42±8 kPa, respectively; effect size: 1.08 [-0.36 to 2.31]; p=0.007). No differences in peak pressure were observed between groups (FAI versus normal) for postures simulating either gait (21±6 versus 22±4 kPa; p=0.902) or stooping (9±2 versus 8±3 kPa; p=0.775) with the numbers available. CONCLUSIONS: The acetabular seal, quantified by the maximum intraarticular pressure, was reduced during pivoting; however, the seal was maintained during simulated gait and stooping. CLINICAL RELEVANCE: Because degeneration is progressive with repetitive impingement, loss of the labral seal starts to be seen during pivoting and may progress from there, but in this small-sample cadaver study that evaluated specimens in middle adulthood, the seal remains intact during simulated gait and stooping. Our study suggests that labral damage secondary to cam-type FAI may reduce the ability of the labral to provide an adequate seal of the central compartment of the hip during loading; however, the extent to which this is affected requires further investigation.


Assuntos
Acetábulo/fisiopatologia , Impacto Femoroacetabular/fisiopatologia , Marcha/fisiologia , Adulto , Feminino , Articulação do Quadril/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Movimento/fisiologia , Estresse Mecânico
19.
J Arthroplasty ; 30(9 Suppl): 86-9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26118566

RESUMO

Tibial stems are frequently used in revision total knee arthroplasty (TKA). We investigated the effect of tibial stems on final component alignment and tray position. Thirty 3D reconstructed cadaveric tibial models were classified according to canal bow angle. After virtual implantation of 120 mm and 200 mm stemmed tibial components, deviation from native mechanical axis was measured. Tibial alignment valgus malposition of up to three degrees occurred and most pronounced with 120 mm stems. Canal alignment using 200 mm stems deviated tray position medially and posteriorly. Mild to moderate valgus bowing of the tibial canal is not uncommon (57% in our series) possibly leading to valgus malalignment. Anatomic conflict between the tibial mechanical axis and intramedullary canal can exist, with alignment and tray placement implications.


Assuntos
Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/métodos , Próteses e Implantes , Tíbia/cirurgia , Algoritmos , Cadáver , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Desenho de Prótese , Tomografia Computadorizada por Raios X
20.
J Arthroplasty ; 30(11): 2012-6, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26021905

RESUMO

This study was performed to study the relationship between the degree of varus deformity of osteoarthritic knees and the anatomic distribution of cartilage pathology. Bone wafers resected from the distal femur and proximal tibia were obtained from 107 patients (195 knees) with primary varus osteoarthritis. Severity and distribution of joint damage was scored for each articular surface and related to potential prognostic factors, including varus deformity, the ligamentous status of the knee, age, gender and BMI. There was highly significant association between varus angulation of the knee and the total damage score for the tibia (P=0.001), but not the femur (P=0.2947). The degree of deformity, and not the status of the ACL alone, determines wear pattern and provides insight for preoperative planning of TKA.


Assuntos
Anteversão Óssea/fisiopatologia , Articulação do Joelho/fisiopatologia , Osteoartrite do Joelho/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho , Anteversão Óssea/patologia , Feminino , Fêmur/patologia , Fêmur/cirurgia , Humanos , Articulação do Joelho/patologia , Articulação do Joelho/cirurgia , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/patologia , Osteoartrite do Joelho/cirurgia , Estudos Prospectivos , Tíbia/patologia , Tíbia/cirurgia
SELEÇÃO DE REFERÊNCIAS