Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Magn Reson ; 15: 55, 2013 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-23787094

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) has become an important diagnostic imaging modality in cardiovascular medicine. However, insufficient image quality may compromise its diagnostic accuracy. We aimed to describe and validate standardized criteria to evaluate a) cine steady-state free precession (SSFP), b) late gadolinium enhancement (LGE), and c) stress first-pass perfusion images. These criteria will serve for quality assessment in the setting of the Euro-CMR registry. METHODS: Thirty-five qualitative criteria were defined (scores 0-3) with lower scores indicating better image quality. In addition, quantitative parameters were measured yielding 2 additional quality criteria, i.e. signal-to-noise ratio (SNR) of non-infarcted myocardium (as a measure of correct signal nulling of healthy myocardium) for LGE and % signal increase during contrast medium first-pass for perfusion images. These qualitative and quantitative criteria were assessed in a total of 90 patients (60 patients scanned at our own institution at 1.5T (n=30) and 3T (n=30) and in 30 patients randomly chosen from the Euro-CMR registry examined at 1.5T). Analyses were performed by 2 SCMR level-3 experts, 1 trained study nurse, and 1 trained medical student. RESULTS: The global quality score was 6.7±4.6 (n=90, mean of 4 observers, maximum possible score 64), range 6.4-6.9 (p=0.76 between observers). It ranged from 4.0-4.3 for 1.5T (p=0.96 between observers), from 5.9-6.9 for 3T (p=0.33 between observers), and from 8.6-10.3 for the Euro-CMR cases (p=0.40 between observers). The inter- (n=4) and intra-observer (n=2) agreement for the global quality score, i.e. the percentage of assignments to the same quality tertile ranged from 80% to 88% and from 90% to 98%, respectively. The agreement for the quantitative assessment for LGE images (scores 0-2 for SNR <2, 2-5, >5, respectively) ranged from 78-84% for the entire population, and 70-93% at 1.5T, 64-88% at 3T, and 72-90% for the Euro-CMR cases. The agreement for perfusion images (scores 0-2 for %SI increase >200%, 100%-200%,<100%, respectively) ranged from 81-91% for the entire population, and 76-100% at 1.5T, 67-96% at 3T, and 62-90% for the Euro-CMR registry cases. The intra-class correlation coefficient for the global quality score was 0.83. CONCLUSIONS: The described criteria for the assessment of CMR image quality are robust with a good inter- and intra-observer agreement. Further research is needed to define the impact of image quality on the diagnostic and prognostic yield of CMR studies.


Assuntos
Doenças Cardiovasculares/diagnóstico , Imagem Cinética por Ressonância Magnética/normas , Garantia da Qualidade dos Cuidados de Saúde , Sistema de Registros , Adulto , Artefatos , Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste , Europa (Continente) , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Razão Sinal-Ruído
2.
J Cardiovasc Magn Reson ; 15: 9, 2013 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-23331632

RESUMO

BACKGROUND: The EuroCMR registry sought to evaluate indications, image quality, safety and impact on patient management of clinical routine CMR in a multi-national European setting. Furthermore, interim analysis of the specific protocols should underscore the prognostic potential of CMR. METHODS: Multi-center registry with consecutive enrolment of patients in 57 centers in 15 countries. More than 27000 consecutive patients were enrolled. RESULTS: The most important indications were risk stratification in suspected CAD/Ischemia (34.2%), workup of myocarditis/cardiomyopathies (32.2%), as well as assessment of viability (14.6%). Image quality was diagnostic in more than 98% of cases. Severe complications occurred in 0.026%, always associated with stress testing. No patient died during or due to CMR. In 61.8% CMR findings impacted on patient management. Importantly, in nearly 8.7% the final diagnosis based on CMR was different to the diagnosis before CMR, leading to a complete change in management. Interim analysis of suspected CAD and risk stratification in HCM specific protocols revealed a low rate of adverse events for suspected CAD patients with normal stress CMR (1.0% per year), and for HCM patients without LGE (2.7% per year). CONCLUSION: The most important indications in Europe are risk stratification in suspected CAD/Ischemia, work-up of myocarditis and cardiomyopathies, as well as assessment of viability. CMR imaging is a safe procedure, has diagnostic image quality in more than 98% of cases, and its results have strong impact on patient management. Interim analyses of the specific protocols underscore the prognostic value of clinical routine CMR in CAD and HCM.


Assuntos
Cardiopatias/diagnóstico , Imageamento por Ressonância Magnética , Idoso , Distribuição de Qui-Quadrado , Europa (Continente) , Feminino , Cardiopatias/mortalidade , Cardiopatias/patologia , Cardiopatias/fisiopatologia , Cardiopatias/terapia , Humanos , Estimativa de Kaplan-Meier , Imageamento por Ressonância Magnética/efeitos adversos , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Valor Preditivo dos Testes , Prognóstico , Sistema de Registros , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Sobrevivência de Tecidos
3.
Front Cardiovasc Med ; 7: 158, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33195445

RESUMO

Aim: Left ventricular non-compaction (LVNC) is perceived as a rare high-risk cardiomyopathy characterized by excess left ventricular (LV) trabeculation. However, there is increasing evidence contesting the clinical significance of LV hyper-trabeculation and the existence of LVNC as a distinct cardiomyopathy. The aim of this study is to assess the association of LV trabeculation extent with cardiovascular morbidity and all-cause mortality in patients undergoing clinical cardiac magnetic resonance (CMR) scans across 57 European centers from the EuroCMR registry. Methods and Results: We studied 822 randomly selected cases from the EuroCMR registry. Image acquisition was according to international guidelines. We manually segmented images for LV chamber quantification and measurement of LV trabeculation (as per Petersen criteria). We report the association between LV trabeculation extent and important cardiovascular morbidities (stroke, atrial fibrillation, heart failure) and all-cause mortality prospectively recorded over 404 ± 82 days of follow-up. Maximal non-compaction to compaction ratio (NC/C) was mean (standard deviation) 1.81 ± 0.67, from these, 17% were above the threshold for hyper-trabeculation (NC/C > 2.3). LV trabeculation extent was not associated with increased risk of the defined outcomes (morbidities, mortality, LV CMR indices) in the whole cohort, or in sub-analyses of individuals without ischaemic heart disease, or those with NC/C > 2.3. Conclusion: Among 882 patients undergoing clinical CMR, excess LV trabeculation was not associated with a range of important cardiovascular morbidities or all-cause mortality over ~12 months of prospective follow-up. These findings suggest that LV hyper-trabeculation alone is not an indicator for worse cardiovascular prognosis.

4.
J Cardiovasc Magn Reson ; 11: 43, 2009 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-19891768

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) is increasingly used in daily clinical practice. However, little is known about its clinical utility such as image quality, safety and impact on patient management. In addition, there is limited information about the potential of CMR to acquire prognostic information. METHODS: The European Cardiovascular Magnetic Resonance Registry (EuroCMR Registry) will consist of two parts: 1) Multicenter registry with consecutive enrolment of patients scanned in all participating European CMR centres using web based online case record forms. 2) Prospective clinical follow up of patients with suspected coronary artery disease (CAD) and hypertrophic cardiomyopathy (HCM) every 12 months after enrolment to assess prognostic data. CONCLUSION: The EuroCMR Registry offers an opportunity to provide information about the clinical utility of routine CMR in a large number of cases and a diverse population. Furthermore it has the potential to gather information about the prognostic value of CMR in specific patient populations.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico , Doença da Artéria Coronariana/diagnóstico , Imageamento por Ressonância Magnética , Sistema de Registros , Europa (Continente) , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Sistemas Computadorizados de Registros Médicos , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Projetos de Pesquisa , Medição de Risco , Fatores de Tempo
5.
JACC Cardiovasc Imaging ; 6(4): 501-11, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23498675

RESUMO

OBJECTIVES: This study aimed to demonstrate that the presence of late gadolinium enhancement (LGE) is a predictor of death and other adverse events in patients with suspected cardiac sarcoidosis. BACKGROUND: Cardiac sarcoidosis is the most important cause of patient mortality in systemic sarcoidosis, yielding a 5-year mortality rate between 25% and 66% despite immunosuppressive treatment. Other groups have shown that LGE may hold promise in predicting future adverse events in this patient group. METHODS: We included 155 consecutive patients with systemic sarcoidosis who underwent cardiac magnetic resonance (CMR) for workup of suspected cardiac sarcoid involvement. The median follow-up time was 2.6 years. Primary endpoints were death, aborted sudden cardiac death, and appropriate implantable cardioverter-defibrillator (ICD) discharge. Secondary endpoints were ventricular tachycardia (VT) and nonsustained VT. RESULTS: LGE was present in 39 patients (25.5%). The presence of LGE yields a Cox hazard ratio (HR) of 31.6 for death, aborted sudden cardiac death, or appropriate ICD discharge, and of 33.9 for any event. This is superior to functional or clinical parameters such as left ventricular (LV) ejection fraction (EF), LV end-diastolic volume, or presentation as heart failure, yielding HRs between 0.99 (per % increase LVEF) and 1.004 (presentation as heart failure), and between 0.94 and 1.2 for potentially lethal or other adverse events, respectively. Except for 1 patient dying from pulmonary infection, no patient without LGE died or experienced any event during follow-up, even if the LV was enlarged and the LVEF severely impaired. CONCLUSIONS: Among our population of sarcoid patients with nonspecific symptoms, the presence of myocardial scar indicated by LGE was the best independent predictor of potentially lethal events, as well as other adverse events, yielding a Cox HR of 31.6 and of 33.9, respectively. These data support the necessity for future large, longitudinal follow-up studies to definitely establish LGE as an independent predictor of cardiac death in sarcoidosis, as well as to evaluate the incremental prognostic value of additional parameters.


Assuntos
Cardiomiopatias/mortalidade , Cardiomiopatias/patologia , Imageamento por Ressonância Magnética , Miocárdio/patologia , Sarcoidose/mortalidade , Sarcoidose/patologia , Adulto , Cardiomiopatias/complicações , Cardiomiopatias/fisiopatologia , Cardiomiopatias/terapia , Meios de Contraste , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Feminino , Gadolínio DTPA , Humanos , Estimativa de Kaplan-Meier , Imageamento por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Valor Preditivo dos Testes , Prognóstico , Modelos de Riscos Proporcionais , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Sarcoidose/complicações , Sarcoidose/fisiopatologia , Sarcoidose/terapia , Volume Sistólico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/prevenção & controle , Fatores de Tempo , Função Ventricular Esquerda
6.
JACC Cardiovasc Imaging ; 4(11): 1171-6, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22093267

RESUMO

OBJECTIVES: The purpose of this study was to assess the frequency, manifestation, and severity of acute adverse reactions associated with administration of several gadolinium-based contrast agents to patients who underwent cardiac magnetic resonance (CMR) imaging in the EuroCMR (European Cardiovascular Magnetic Resonance) Registry multinational and multicenter setting. BACKGROUND: The frequency, manifestations, and severity of acute adverse reactions associated with gadolinium-based contrast agents in the specific setting of cardiovascular magnetic resonance have not been systematically evaluated yet. METHODS: This is a multicenter and multinational registry with consecutive enrollment of patients in 45 European centers. During the current observation, 17,767 doses of gadolinium-based contrast agent were administered to 17,767 patients. The mean dose was 25.6 ml (range 5 to 80 ml), which is equivalent to 0.128 mmol/kg (range 0.012 to 0.3 mmol/kg). RESULTS: Thirty acute adverse reactions due to contrast administration occurred (0.17%). All reactions were classified as mild according to the American College of Radiology definition. The most frequent complaints following contrast administration were rashes and hives (9 of 30), followed by nausea (7 of 30), and anxiety (6 of 30). The event rate ranged from 0.06% (linear nonionic agent gadodiamide) to 0.47% (linear ionic agent gadobenate dimeglumine). Interestingly, we also found different event rates between the three main indications for CMR imaging, ranging from 0.1% (risk stratification in suspected coronary artery disease) to 0.42% (viability in known coronary artery disease). CONCLUSIONS: The incidence of acute adverse reactions after administration of gadolinium-based contrast in the "off-label" setting of CMR in our population was not different from the incidence in the U.S. Food and Drug Administration-approved general radiology setting. Thus, the off-label use of gadolinium-based contrast in CMR should be regarded as safe concerning the frequency, manifestation, and severity of acute events.


Assuntos
Meios de Contraste/efeitos adversos , Gadolínio/efeitos adversos , Cardiopatias/diagnóstico , Imageamento por Ressonância Magnética , Adolescente , Adulto , Idoso , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Sistema de Registros , Medição de Risco , Fatores de Risco , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA