Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 368
Filtrar
1.
Am Heart J ; 269: 139-148, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38151142

RESUMO

BACKGROUND: Left ventricular (LV) systolic dysfunction worsens outcomes in patients undergoing percutaneous coronary intervention (PCI). The objective of this study, therefore, was to evaluate outcomes of pLVAD-supported high-risk PCI (HRPCI) patients according to LV ejection fraction (LVEF). METHODS: Patients from the PROTECT III study undergoing pLVAD-supported HRPCI were stratified according to baseline LVEF: severe LV dysfunction (LVEF <30%), mild and moderate LV dysfunction (LVEF ≥30% to <50%), or preserved LV function (LVEF ≥50%). Major adverse cardiovascular and cerebrovascular events (MACCE: composite of all-cause death, myocardial infarction, stroke/transient ischemic attack, and repeat revascularization), and PCI-related complications were assessed at 90 days and mortality was assessed at 1-year. RESULTS: From March 2017 to March 2020, 940 patients had evaluable baseline LVEF recorded in the study database. Patients with preserved LV function were older, more frequently presented with myocardial infarction, and underwent more left main PCI and atherectomy. Immediate PCI-related coronary complications were infrequent (2.7%, overall), similar between groups (P = 0.98), and not associated with LVEF. Unadjusted 90-day MACCE rates were similar among LVEF groups; however, as a continuous variable, LVEF was associated with both 90-day MACCE (adj.HR per 5% 0.89, 95% CI [0.80, 0.98], P = 0.018) and 1-year mortality (adj.HR per 5% 0.84 [0.78, 0.90], P <0.0001). CONCLUSIONS: Patients who underwent pLVAD-supported HRPCI exhibited low incidence of PCI-related complications, regardless of baseline LVEF. However, LVEF was associated with 90-day MACCE and 1-year mortality.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Disfunção Ventricular Esquerda , Humanos , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Infarto do Miocárdio/complicações , Doença da Artéria Coronariana/complicações
2.
J Card Fail ; 30(10): 1244-1254, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39389734

RESUMO

BACKGROUND: Right ventricular dysfunction (RVD) is an important prognostic factor in several cardiac conditions, including acute and chronic heart failure. The impact of baseline RVD on clinical outcomes of patients undergoing high-risk percutaneous coronary intervention (HRPCI) supported by Impella is unknown. METHODS: Patients from the single-arm, multicenter PROTECT III study of Impella-supported HRPCI were stratified based on the presence or absence of RVD. RVD was quantitatively assessed by an echocardiography core laboratory and was defined as fractional area change < 35%, tricuspid annular plane systolic excursion < 17 mm or pulsed-wave Doppler S-wave of the lateral tricuspid annulus < 9.5 cm/s. Procedural outcomes, 90-day major adverse cardiac and cerebrovascular events (MACCE: the composite of all-cause mortality, myocardial infarction, stroke/TIA, and repeat revascularization), and 1-year mortality were assessed. RESULTS: Of the 239 patients who underwent RV function assessment, 124 were found to have RVD. Lower left ventricular ejection fraction, higher blood urea nitrogen levels, and more severe RV dilation were independently associated with RVD. The incidence of hypotensive episodes during PCI, the proportion of patients requiring prolonged Impella support, the completeness of revascularization, and the rate of in-hospital mortality did not differ significantly between patients with vs without RVD. However, 90-day MACCE rates were higher in those with RVD, and RVD was a robust predictor of 1-year mortality in multivariable Cox-regression analyses. CONCLUSION: In patients undergoing HRPCI with Impella, RVD was associated with more advanced biventricular failure. The use of Impella support during HRPCI facilitated effective revascularization, even in those with concomitant RVD. Nevertheless, RVD was associated with unfavorable long-term prognoses.


Assuntos
Coração Auxiliar , Intervenção Coronária Percutânea , Disfunção Ventricular Direita , Humanos , Masculino , Feminino , Intervenção Coronária Percutânea/métodos , Idoso , Disfunção Ventricular Direita/fisiopatologia , Disfunção Ventricular Direita/diagnóstico , Pessoa de Meia-Idade , Mortalidade Hospitalar/tendências , Resultado do Tratamento , Fatores de Risco , Seguimentos
3.
J Card Fail ; 30(10): 1287-1299, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39389740

RESUMO

BACKGROUND: Patients experiencing loss of pulse pressure (LOPP) during high-risk percutaneous coronary intervention (HR-PCI) are transiently dependent on mechanical circulatory support devices. We sought to define the frequency and clinic outcomes of patients who experience LOPP during HR-PCI. METHODS AND RESULTS: Patients enrolled in the PROTECT III study and had automated Impella controller logs capturing real-time hemodynamics were included in this analysis. A LOPP event was defined as a mean pulse pressure on Impella of <20 mm Hg for ≥5 seconds during PCI. Clinical characteristics and outcomes were then compared between those with and without LOPP. Logistic regression identified clinical and hemodynamic predictors of LOPP. We included 302 patients, of whom 148 patients (49%) experienced LOPP. Age, sex, and comorbidities were similar in patients with and without LOPP. Mean baseline systolic blood pressure (118.6 mm Hg vs 129.8 mm Hg; P < .001) and mean arterial pressure (86.9 mm Hg vs 91.6 mm Hg; P = .011) were lower in patients with LOPP, whereas heart rate (78 bpm vs 73 bpm; P = .012) was higher. Anatomical complexity was similar between groups. Patients with LOPP were more likely to experience major adverse cardiac and cerebrovascular events (23.5% vs 8.8%; P = .002), acute kidney injury (10.1% vs 2.6%; P = .030), and death (20.2% vs 7.9%; P = .008) within 90 days. A low baseline systolic blood pressure and cardiomyopathy were the strongest predictors of LOPP (P = .003 and P = .001, respectively). CONCLUSIONS: LOPP on Impella during HR-PCI was common and occurred more frequently in patients with cardiomyopathy and a low systolic blood pressure. LOPP was strongly associated with higher 90-day major adverse cardiac and cerebrovascular events, acute kidney injury, and mortality. Condensed Abstract We sought to define the frequency and clinic outcomes of patients who experience LOPP during high-risk percutaneous coronary intervention (HR-PCI). We included 302 patients, of whom 148 (49%) experienced LOPP. Patients with LOPP were more likely to experience major adverse cardiac and cerebrovascular events (23.5% vs 8.8%; P = .002), acute kidney injury (10.1% vs 2.6%; P = .030), and death (20.2% vs 7.9%; P = .008) within 90 days. A low baseline systolic blood pressure and cardiomyopathy were the strongest predictors of LOPP (P = .003 and P = .001, respectively).


Assuntos
Pressão Sanguínea , Coração Auxiliar , Intervenção Coronária Percutânea , Humanos , Masculino , Feminino , Intervenção Coronária Percutânea/métodos , Idoso , Pessoa de Meia-Idade , Pressão Sanguínea/fisiologia , Resultado do Tratamento , Hipotensão/epidemiologia , Hipotensão/fisiopatologia , Hipotensão/etiologia
4.
Catheter Cardiovasc Interv ; 103(6): 1023-1034, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38639143

RESUMO

BACKGROUND: The clinical efficacy and safety of alcohol septal ablation (ASA) for obstructive hypertrophic cardiomyopathy (HCM) have been well-established; however, less is known about outcomes in patients undergoing preemptive ASA before transcatheter mitral valve replacement (TMVR). AIMS: The goal of this study is to characterize the procedural characteristics and examine the clinical outcomes of ASA in both HCM and pre-TMVR. METHODS: This retrospective study compared procedural characteristics and outcomes in patient who underwent ASA for HCM and TMVR. RESULTS: In total, 137 patients were included, 86 in the HCM group and 51 in the TMVR group. The intraventricular septal thickness (mean 1.8 vs. 1.2 cm; p < 0.0001) and the pre-ASA LVOT gradient (73.6 vs. 33.8 mmHg; p ≤ 0.001) were higher in the HCM group vs the TMVR group. The mean volume of ethanol injected was higher (mean 2.4 vs. 1.7 cc; p < 0.0001). The average neo-left ventricular outflow tract area increased significantly after ASA in the patients undergoing TMVR (99.2 ± 83.37 mm2 vs. 196.5 ± 114.55 mm2; p = <0.0001). The HCM group had a greater reduction in the LVOT gradient after ASA vs the TMVR group (49.3 vs. 18 mmHg; p = 0.0040). The primary composite endpoint was higher in the TMVR group versus the HCM group (50.9% vs. 25.6%; p = 0.0404) and had a higher incidence of new permanent pacemaker (PPM) (25.5% vs. 18.6%; p = 0.3402). The TMVR group had a higher rate of all-cause mortality (9.8% vs. 1.2%; p = 0.0268). CONCLUSIONS: Preemptive ASA before TMVR was performed in patients with higher degree of clinical comorbidities, and correspondingly is associated with worse short-term clinical outcomes in comparison to ASA for HCM patients. ASA before TMVR enabled percutaneous mitral interventions in a small but significant minority of patients that would have otherwise been excluded. The degree of LVOT and neoLVOT area increase is significant and predictable.


Assuntos
Técnicas de Ablação , Cateterismo Cardíaco , Cardiomiopatia Hipertrófica , Etanol , Implante de Prótese de Valva Cardíaca , Valva Mitral , Humanos , Estudos Retrospectivos , Masculino , Etanol/administração & dosagem , Etanol/efeitos adversos , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/mortalidade , Cardiomiopatia Hipertrófica/terapia , Cardiomiopatia Hipertrófica/cirurgia , Cardiomiopatia Hipertrófica/fisiopatologia , Feminino , Resultado do Tratamento , Técnicas de Ablação/efeitos adversos , Técnicas de Ablação/mortalidade , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Cateterismo Cardíaco/instrumentação , Pessoa de Meia-Idade , Fatores de Risco , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Fatores de Tempo , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Recuperação de Função Fisiológica , Idoso de 80 Anos ou mais , Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/mortalidade
5.
Eur Heart J ; 44(46): 4862-4873, 2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-37930776

RESUMO

BACKGROUND AND AIMS: For patients with symptomatic, severe tricuspid regurgitation (TR), early results of transcatheter tricuspid valve (TV) intervention studies have shown significant improvements in functional status and quality of life associated with right-heart reverse remodelling. Longer-term follow-up is needed to confirm sustained improvements in these outcomes. METHODS: The prospective, single-arm, multicentre TRISCEND study enrolled 176 patients to evaluate the safety and performance of transcatheter TV replacement in patients with ≥moderate, symptomatic TR despite medical therapy. Major adverse events, reduction in TR grade and haemodynamic outcomes by echocardiography, and clinical, functional, and quality-of-life parameters are reported to one year. RESULTS: Enrolled patients were 71.0% female, mean age 78.7 years, 88.0% ≥ severe TR, and 75.4% New York Heart Association classes III-IV. Tricuspid regurgitation was reduced to ≤mild in 97.6% (P < .001), with increases in stroke volume (10.5 ± 16.8 mL, P < .001) and cardiac output (0.6 ± 1.2 L/min, P < .001). New York Heart Association class I or II was achieved in 93.3% (P < .001), Kansas City Cardiomyopathy Questionnaire score increased by 25.7 points (P < .001), and six-minute walk distance increased by 56.2 m (P < .001). All-cause mortality was 9.1%, and 10.2% of patients were hospitalized for heart failure. CONCLUSIONS: In an elderly, highly comorbid population with ≥moderate TR, patients receiving transfemoral EVOQUE transcatheter TV replacement had sustained TR reduction, significant increases in stroke volume and cardiac output, and high survival and low hospitalization rates with improved clinical, functional, and quality-of-life outcomes to one year. Funded by Edwards Lifesciences, TRISCEND ClinicalTrials.gov number, NCT04221490.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Idoso , Masculino , Insuficiência da Valva Tricúspide/epidemiologia , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Índice de Gravidade de Doença
6.
Catheter Cardiovasc Interv ; 101(1): 164-169, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36378598

RESUMO

Aspiration thrombectomy with the AngioVac is approved for percutaneous removal of thrombus in the venous system. While not approved for aspiration of thrombus or other mass in the left heart or arterial system, it has been used in that setting. Patients with left heart or arterial mass are often deemed unfavorable for surgery and treated conservatively. This may not be the best option for all patients, as some may have lesions that represent a short-term increased risk of complications, for which intervention and aspiration could be considered reasonable. Unfortunately, femoral arteries sizes often cannot accommodate the Angiovac current aspiration cannula dimensions. Here, we demonstrated trans-caval approach for aspiration thrombectomy of extensive aortic mobile plaque and thrombus.


Assuntos
Placa Aterosclerótica , Trombose , Humanos , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Resultado do Tratamento , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/cirurgia , Trombectomia/efeitos adversos
7.
Catheter Cardiovasc Interv ; 102(1): 145-154, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37178388

RESUMO

BACKGROUND: Mitral valve transcatheter edge-to-edge repair (M-TEER) is an effective option for treatment of mitral regurgitation (MR). We previously reported favorable 2-year outcomes for the PASCAL transcatheter valve repair system. OBJECTIVES: We report 3-year outcomes from the multinational, prospective, single-arm CLASP study with analysis by functional MR (FMR) and degenerative MR (DMR). METHODS: Patients with core-lab determined MR ≥ 3+ were deemed candidates for M-TEER by the local heart team. Major adverse events were assessed by an independent clinical events committee to 1 year and by sites thereafter. Echocardiographic outcomes were evaluated by the core laboratory to 3 years. RESULTS: The study enrolled 124 patients, 69% FMR; 31% DMR (60% NYHA class III-IVa, 100% MR ≥ 3+). The 3-year Kaplan-Meier estimate for survival was 75% (66% FMR; 92% DMR) and freedom from heart failure hospitalization (HFH) was 73% (64% FMR; 91% DMR), with 85% reduction in annualized HFH rate (81% FMR; 96% DMR) (p < 0.001). MR ≤ 2+ was achieved and maintained in 93% of patients (93% FMR; 94% DMR) and MR ≤ 1+ in 70% of patients (71% FMR; 67% DMR) (p < 0.001). The mean left ventricular end-diastolic volume (181 mL at baseline) decreased progressively by 28 mL [p < 0.001]. NYHA class I/II was achieved in 89% of patients (p < 0.001). CONCLUSIONS: The 3-year results from the CLASP study demonstrated favorable and durable outcomes with the PASCAL transcatheter valve repair system in patients with clinically significant MR. These results add to the growing body of evidence establishing the PASCAL system as a valuable therapy for patients with significant symptomatic MR.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estudos Prospectivos , Resultado do Tratamento
8.
Echocardiography ; 40(8): 884-887, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37319117

RESUMO

Pacer wire induced tricuspid regurgitation is not well-understood. The mechanisms behind pacer wired induced tricuspid regurgitation have not been clearly defined. This clinical vignette sets to identify different technical mechanisms behind cardiac lead induced tricuspid regurgitation to help optimize cardiac lead implantation strategies for future device implantation.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Resultado do Tratamento , Ecocardiografia Tridimensional , Tomografia Computadorizada por Raios X
9.
Echocardiography ; 40(11): 1285-1291, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37842844

RESUMO

Left ventricular pseudoaneurysm (PSA) after surgical aortic valve replacement (AVR) is a known but uncommon complication. It is associated with risks such as thromboembolism and life-threatening rupture. Surgical repair has traditionally been utilized in low-risk patients but transcatheter closure has become a promising therapeutic option. This case report describes the utility of multimodality imaging in pre-, intra-, and post-procedural evaluation of transcatheter PSA closure and is among the first to demonstrate the utility of 3D print model.


Assuntos
Falso Aneurisma , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Imagem Multimodal , Resultado do Tratamento
10.
Am Heart J ; 254: 122-132, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36058253

RESUMO

BACKGROUND: Despite successful primary percutaneous coronary intervention (PCI) in ST-elevation myocardial infarction (STEMI), myocardial salvage is often suboptimal, resulting in large infarct size and increased rates of heart failure and mortality. Unloading of the left ventricle (LV) before primary PCI may reduce infarct size and improve prognosis. STUDY DESIGN AND OBJECTIVES: STEMI-DTU (NCT03947619) is a prospective, randomized, multicenter trial designed to compare mechanical LV unloading with the Impella CP device for 30 minutes prior to primary PCI to primary PCI alone without LV unloading. The trial aims to enroll approximately 668 subjects, with a potential sample size adaptation, with anterior STEMI with a primary end point of infarct size as a percent of LV mass evaluated by cardiac magnetic resonance at 3-5 days after PCI. The key secondary efficacy end point is a hierarchical composite of the 1-year rates of cardiovascular mortality, cardiogenic shock ≥24 hours after PCI, use of a surgical left ventricular assist device or heart transplant, heart failure, intra-cardiac defibrillator or chronic resynchronization therapy placement, and infarct size at 3 to 5 days post-PCI. The key secondary safety end point is Impella CP-related major bleeding or major vascular complications within 30 days. Clinical follow-up is planned for 5 years. CONCLUSIONS: STEMI-DTU is a large-scale, prospective, randomized trial evaluating whether mechanical unloading of the LV by the Impella CP prior to primary PCI reduces infarct size and improves prognosis in patients with STEMI compared to primary PCI alone without LV unloading.


Assuntos
Insuficiência Cardíaca , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Estudos Prospectivos , Insuficiência Cardíaca/terapia , Resultado do Tratamento
11.
Am Heart J ; 249: 1-11, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35288105

RESUMO

BACKGROUND: Severe coronary artery calcification has been associated with stent underexpansion, procedural complications, and increased rates of early and late adverse clinical events in patients undergoing percutaneous coronary intervention. To date, no lesion preparation strategy has been shown to definitively improve outcomes of percutaneous coronary intervention for calcified coronary artery lesions. STUDY DESIGN AND OBJECTIVES: ECLIPSE (NCT03108456) is a prospective, randomized, multicenter trial designed to evaluate two different vessel preparation strategies in severely calcified coronary artery lesions. The routine use of the Diamondback 360 Coronary Orbital Atherectomy System is compared with conventional balloon angioplasty prior to drug-eluting stent implantation. The trial aims to enroll approximately 2000 subjects with a primary clinical endpoint of target vessel failure, defined as the composite of cardiac death, target vessel-related myocardial infarction, or ischemia-driven target vessel revascularization assessed at 1 year. The co-primary endpoint is the acute post-procedural in-stent minimal cross-sectional area as assessed by optical coherence tomography in a 500-subject cohort. Enrollment is anticipated to complete in 2022 with total clinical follow-up planned for 2 years. CONCLUSIONS: ECLIPSE is a large-scale, prospective randomized trial powered to demonstrate whether a vessel preparation strategy of routine orbital atherectomy system is superior to conventional balloon angioplasty prior to implantation of drug-eluting stents in severely calcified coronary artery lesions.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Calcificação Vascular , Aterectomia , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/etiologia , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/cirurgia
12.
Am Heart J ; 248: 139-149, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35192839

RESUMO

BACKGROUND: Contemporary practices for hemodynamically supported high-risk percutaneous coronary intervention have evolved over the last decade. This study sought to compare outcomes of the prospective, multicenter, PROTECT III study to historic patients treated with Impella in the PROTECT II randomized controlled trial. METHODS: Of 1,134 patients enrolled in PROTECT III from March 2017 to March 2020, 504 were "PROTECT II-like" (met eligibility for PROTECT II randomized controlled trial) and are referred to as PROTECT III for comparative analysis. Major adverse cardiac and cerebrovascular events (MACCE), comprising all-cause mortality, stroke/transient ischemic attack, myocardial infarction, and repeat revascularization, were compared at hospital discharge and 90 days. RESULTS: Compared with PROTECT II (N = 216), PROTECT III patients were less often Caucasian (77.1% vs 83.8%, P = .045), with less prior CABG (13.7% vs 39.4%; P < .001) and prior myocardial infarction (40.7% vs 69.3%; P < .001). More PROTECT III patients underwent rotational atherectomy (37.1% vs 14.8%, P < .001) and duration of support was longer (median 1.6 vs 1.3 hours; p<0.001), with greater improvement achieved in myocardial ischemia jeopardy scores (7.0±2.4 vs 4.4±2.9; P < .001) and SYNTAX scores (21.4±10.8 vs 15.7±9.5; P < .001). In-hospital bleeding requiring transfusion was significantly lower in PROTECT III (1.8% vs 9.3%; P < .001), as was procedural hypotension (2.2% vs 10.1%; P < .001) and cardiopulmonary resuscitation or ventricular arrhythmia (1.6% vs 6.9%; P < .001). At 90 days, MACCE was 15.1% and 21.9% in PROTECT III and PROTECT II, respectively (p=0.037). Following propensity score matching, Kaplan-Meier analysis showed improved 90-day MACCE rates in PROTECT III (10.4% vs 16.9%, P = .048). CONCLUSIONS: The PROTECT III study demonstrates improved completeness of revascularization, less bleeding, and improved 90-day clinical outcomes compared to PROTECT II for Impella-supported high-risk percutaneous coronary intervention among patients with severely depressed LVEF.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Doença da Artéria Coronariana/terapia , Humanos , Estudos Prospectivos , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 99(3): 934-942, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34843639

RESUMO

OBJECTIVE: Evaluate transcatheter mitral valve replacement (TMVR) valve-in-valve (VIV) outcomes in three different mitral bioprostheses (of comparable measured internal diameters) under stable hemodynamic and surgical conditions by bench, echocardiographic, computerized tomography (CT), and autopsy comparisons pre- and post-valve implantation in a porcine model under matched controlled conditions. BACKGROUND: Impact of surgical bioprosthesis design on TMVR VIV procedures is unknown. METHODS: Fifteen similar-sized Yorkshire pigs underwent pre-procedural CT screening. Twelve had consistent anatomic features and underwent implantation of mitral bioprostheses. Four valves from each of three manufacturers were implanted in randomized fashion: 27-mm Epic, 27-mm Mosaic, and 25-mm Mitris, followed by TMVR VIV with 26 Edwards Sapien3. Post-VIV, suprasternal TEE studies were performed to assess hemodynamic function, followed by a gated contrast CT. After euthanasia, animals underwent necropsy for anatomic evaluation. RESULTS: All 12 animals had successful VIV implantation with no study deaths. The post vivMitris (3.77 ± 0.36)/(2.2 ± 0.25 mmHg) had the lowest peak/mean trans-mitral gradient and the vivEpic the highest (15.5 ± 2.55)/(7.09 ± 1.13 mmHg). All THVs (transcatheter heart valves) had greatest deformation within the center of the THV frame; with the smallest waist opening area in the vivEpic (329 ± 35.8 mm2 ) and greatest in the vivMitris (414 ± 33.12 mm2 ). Bioprosthetic frames without obvious radiopaque markers resulted in the most ventricular implantation of the THV's anteroseptal frame (Epic: -4.52 ± 0.76 mm), versus the most radiopaque bioprosthesis (Mitris: -1.18 ± 2.95 mm), and higher peak LVOT gradients (Epic: 4.82 ± 1.61 mmHg; Mitris: 2.91 ± 1.47 mmHg). CONCLUSIONS: The current study demonstrates marked variations in hemodynamics, THV opening area, and anatomic dimensions among measured similarly sized mitral bioprostheses. These data suggest a critical need for understanding the potential impact of variations in bioprosthesis design on TMVR VIV clinical outcomes.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Animais , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Desenho de Prótese , Falha de Prótese , Suínos , Resultado do Tratamento
14.
Catheter Cardiovasc Interv ; 100(4): 628-635, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35900207

RESUMO

OBJECTIVES: To study the safety and efficacy of AngioVac for left-sided transcatheter vacuum-assisted mass extraction (TVME). BACKGROUND: The AngioVac system is approved for right-sided TVME and has emerged as an effective and safe alternative for open surgical treatment. The use of the AngioVac device for aspiration of left-sided TVME has been limited. METHODS: Consecutive patients from two Michigan centers who underwent left-sided TVME were included. Data on patient demographics, procedural information, in-hospital and follow-up events were collected through electronic medical records review. Technical success was defined as aspirating of 70%-100% of the material. RESULTS: Ten patients (mean age 58.3 [±17.3] years, 50% male) were included. Indications for TMVE were in large for recurrent embolic events. All patients underwent bilateral cerebro-embolic protection using the Sentinel device. The total mean procedure time was 192.5 (±47.5) min of which the meantime for active aspiration (bypass time) was 9.3 (±4.2) min. The circuit configuration was: arteriovenous (AV) in four cases and arterioarterial (AA) in six cases. Successful aspiration was achieved in 80% of cases. No complications were reported (range follow-up 1-16 months). CONCLUSIONS: Our small case series demonstrates the feasibility and safety of the AngioVac system in left-sided mass extraction. Larger trials are needed to further demonstrate its effectiveness and safety and potentially apply for on-label use.


Assuntos
Trombectomia , Feminino , Humanos , Masculino , Michigan , Pessoa de Meia-Idade , Trombectomia/efeitos adversos , Resultado do Tratamento , Vácuo
15.
Catheter Cardiovasc Interv ; 100(4): 568-574, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36073018

RESUMO

OBJECTIVES: To evaluate characteristics and outcomes of patients presenting with acute myocardial infarction and cardiogenic shock (AMICS) during the coronavirus disease 2019 (COVID-19) pandemic. BACKGROUND: The COVID-19 pandemic has created challenges in delivering acute cardiovascular care. Quality measures and outcomes of patients presenting with AMICS during COVID-19 in the United States have not been well described. METHODS: We identified 406 patients from the National Cardiogenic Shock Initiative (NCSI) with AMICS and divided them into those presenting before (N = 346, 5/9/2016-2/29/2020) and those presenting during the COVID-19 pandemic (N = 60, 3/1/2020-11/10/2020). We compared baseline clinical data, admission characteristics, and outcomes. RESULTS: The median age of the cohort was 64 years, and 23.7% of the group was female. There were no significant differences in age, sex, and medical comorbidities between the two groups. Patients presenting during the pandemic were less likely to be Black compared to those presenting prior. Median door to balloon (90 vs. 88 min, p = 0.38), door to support (88 vs. 78 min, p = 0.13), and the onset of shock to support (74 vs. 62 min, p = 0.15) times were not significantly different between the two groups. Patients presented with ST-elevation myocardial infarction more often during the COVID-19 period (95.0% vs. 80.0%, p = 0.005). In adjusted logistic regression models, COVID-19 period did not significantly associate with survival to discharge (odds ratio [OR] 1.09, 95% confidence interval [CI] 0.54-2.19, p = 0.81) or with 1-month survival (OR 0.82, 95% CI 0.42-1.61, p = 0.56). CONCLUSIONS: Care of patients presenting with AMICS has remained robust among hospitals participating in the NCSI during the COVID-19 pandemic.


Assuntos
COVID-19 , Coração Auxiliar , Infarto do Miocárdio , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , COVID-19/complicações , Feminino , Coração Auxiliar/efeitos adversos , Humanos , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/terapia , Pandemias , Intervenção Coronária Percutânea/efeitos adversos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/etiologia , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Resultado do Tratamento , Estados Unidos/epidemiologia
16.
Catheter Cardiovasc Interv ; 99(3): 943-948, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34534413

RESUMO

OBJECTIVES: To determine the safety and efficacy of the conveyor cardiovascular system (CCS) to facilitate the delivery of large profile transcatheter valve devices. BACKGROUND: Transcatheter valve devices rely on force provided by the operator to be delivered to their intended position. This delivery may be challenging in a variety of anatomic scenarios. The ability to provide steering from the tip of the device by forming an arterial venous loop may help overcome these challenges. METHODS: Between May, 2019 and October, 2020, five patients were recruited for delivery of transcatheter valve devices with the CCS. These patients were deemed by the operators to have challenging anatomy which could make conventional valve delivery difficult or impossible. These patients were recruited as part of an FDA approved early feasibility study or through an institutional review board approved compassionate use protocol. RESULTS: Three patients underwent transcatheter mitral valve replacement with a SAPIEN-3 valve. One patient each underwent transcatheter aortic valve (TAVR) implantation with a SAPIEN 3 and 1 patient underwent TAVR implantation with a Lotus valve. All patients underwent successful implantation of the valve and removal of the CCS and valve delivery systems. There was no more than trivial mitral regurgitation post procedure in any patient and there was no more than trivial paravavular leak. There were no major in-hospital complications. CONCLUSIONS: The CCS facilitates the delivery of large profile transcatheter valve devices in challenging anatomic scenarios. Further studies are needed with additional valve technologies.


Assuntos
Estenose da Valva Aórtica , Sistema Cardiovascular , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
17.
Catheter Cardiovasc Interv ; 100(1): 163-168, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35568977

RESUMO

OBJECTIVE: We aim to report on the efficacy and safety of large bore venous access (LBVA) preclosure with Perclose™ (Abbott Vascular Devices) suture-mediated device use following transcatheter edge-to-edge (TEER) and replacement (TMVR). BACKGROUND: Patients requiring TEER and TMVR require LBVA. Clinical outcome data on the use of suture-mediated devices for LBVA site closure are limited. METHODS: Between 2012 and 2019, 354 consecutive high-risk patients with mitral valvular heart disease underwent TEER (n = 287) with MitraClip and TMVR (n = 67) with Edwards Sapien Valves. Patients had LBVA with 24 or 16 French sheaths. All patients underwent preclosure of LBVA except for one that underwent manual hemostasis. RESULTS: There were no closure device failures. None of the cases required surgical repair of the access site following venous preclosure. Two cases had large hematomas (>6 cm) following Perclose in each group. Six cases had small hematomas (<6 cm and >2 cm) with three in each group. There was one major bleeding using Mitral Valve Academic Research Consortium 2 definition (retroperitoneal bleed from arterial puncture) unrelated to the venous closure. Transfusion related to vascular access complication was required in five cases. There were two immediate acute deep venous thromboses postprocedure; one of which occurred after preclosure. There were no arteriovenous malformations, pseudoaneurysms, or access site infections reported following Perclose. CONCLUSION: In this large sample size analysis, Proglide preclosure technique is a feasible and safe alternative approach to achieving hemostasis after removal of LBVA sheaths in patients undergoing TEER and TMVR. Randomized trials are needed to compare the different modalities of hemostasis.


Assuntos
Doenças das Valvas Cardíacas , Dispositivos de Oclusão Vascular , Doenças das Valvas Cardíacas/cirurgia , Hematoma/etiologia , Hemorragia/etiologia , Hemorragia/prevenção & controle , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Técnicas de Sutura/efeitos adversos , Resultado do Tratamento , Dispositivos de Oclusão Vascular/efeitos adversos
18.
Catheter Cardiovasc Interv ; 99(3): 650-657, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34343409

RESUMO

BACKGROUND: Increasing vasopressor dose is associated with increasing mortality in patients presenting with acute myocardial infarction and cardiogenic shock (AMICS). It is unknown whether the use of vasopressors is independently harmful or if their use is secondary to decreasing intrinsic cardiac power output (CPO). Mechanical circulatory support (MCS) devices enhance CPO. We sought to evaluate the independent impact of increasing vasopressor dose on survival in the National Cardiogenic Shock Initiative (NCSI). METHODS: The NCSI is a single arm prospective trial evaluating outcomes associated with the use of MCS using Impella in patients with AMICS. Early initiation of MCS placement before percutaneous coronary intervention (PCI) and rapid de-escalation of vasopressors guided by systematic use of invasive hemodynamic measures led to 70% in-hospital survival for the first 300 patients enrolled from July 2016 to December 2019 in 57 U.S. sites. RESULTS: Hemodynamic measures were obtained immediately after MCS and PCI. Survival curves were constructed based on CPO and use of vasopressors. For patients with CPO ≤0.6 W, survival was 77.3%, 45.0%, and 35.3% when 0, 1, or ≥ 2 vasopressors were used (p = 0.02). Similarly, for patients with CPO >0.6 W survival was 81.7%, 72.6%, and 56.8%, respectively (p = 0.01). Logistic regression analysis demonstrated that increasing vasopressor requirements were independently associated with increasing mortality (p = 0.02). CONCLUSION: Increasing vasopressor requirement is associated with increased mortality in AMICS independent of underlying CPO. Methods to decrease the need for vasopressors may enhance survival in AMICS.


Assuntos
Coração Auxiliar , Infarto do Miocárdio , Intervenção Coronária Percutânea , Coração Auxiliar/efeitos adversos , Humanos , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/terapia , Resultado do Tratamento
19.
J Card Surg ; 37(9): 2937-2942, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33533038

RESUMO

BACKGROUND: As transcatheter aortic valve replacement (TAVR) procedures increase, more data is available on the development of conduction abnormalities requiring permanent pacemaker (PPM) implantation post-TAVR. Mechanistically, new pacemaker implantation and incidence of associated tricuspid regurgitation (TR) post-TAVR is not well understood. Studies have evaluated the predictability of patient anatomy towards risk for needing permanent pacemaker (PPM) post-TAVR; however, little has been reported on new PPM and TR in patients post-TAVR. METHODS: This retrospective study identified patients at our health system who underwent PPM following TAVR from January 2014 to June 2018. Data from both TAVR and PPM procedures as well as patient demographics were collected. Echocardiographic data before TAVR, between TAVR and PPM placement, and the most recent echocardiogram at the time of chart review were analyzed. RESULTS: Of 796 patients who underwent TAVR between January 2014 and June 2018, 89 patients (11%) subsequently required PPM. Out of the 89 patients who required PPM implantation, 82 patients had pre-TAVR and 2-year post-TAVR echocardiographic imaging data. At baseline, 22% (18/82) of patients had at least moderate TR. At 2-year post-TAVR echocardiographic imaging follow-up; 27% (22/82) of patients had at least moderate TR. Subgroup analysis was performed according to the TAVR valve size implanted. In patients who received a TAVR device < 29 mm in diameter in size, 25% (11/44) had worsening TR. In patients who received a TAVR device ≥ 29 mm in diameter, 37% (14/38) had worsening TR. CONCLUSION: We have demonstrated a patient population that may be predisposed to developing worsening TR and right heart function after TAVR and Pacemaker implantation.


Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Insuficiência da Valva Tricúspide , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/epidemiologia , Insuficiência da Valva Tricúspide/etiologia
20.
Circulation ; 141(14): 1184-1197, 2020 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-32250695

RESUMO

The recent widespread availability and use of mechanical circulatory support is transforming the management and outcomes of cardiogenic shock (CS). Clinical decision-making regarding the optimization of therapies for patients with CS can be guided effectively by hemodynamic monitoring with a pulmonary artery catheter (PAC). Because several studies regarding the benefit of PACs are ambiguous, the use of PACs is variable among clinicians treating patients with CS. More notable is that PAC use has not been studied as part of a randomized, controlled trial in patients with CS with or without mechanical circulatory support. Standardized approaches to hemodynamic monitoring in these patients can improve decision-making and outcomes. In this review, we summarize the hemodynamics of CS and mechanical circulatory support with PAC-derived measurements, and provide a compelling rationale for the use of PAC monitoring in patients with CS receiving mechanical circulatory support.


Assuntos
Monitorização Hemodinâmica/métodos , Choque Cardiogênico/fisiopatologia , Choque Cardiogênico/terapia , Hemodinâmica , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA