Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Rapid Commun Mass Spectrom ; 35(7): e9041, 2021 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-33415785

RESUMO

RATIONALE: Gangliosides (GS) are attractive targets in biomarker discovery because of their physiological significance in numerous human diseases including certain cancers and developmental and metabolic disorders. The robust strategy described here enables the profiling of numerous GS while obtaining quantitative data of exploratory biomarkers present in human plasma and whole blood. METHOD: The GS from human blood, human plasma, and several cell lines were extracted using a mixture of methanol and isopropanol/0.1% formic acid followed by direct analysis of the supernatant. The simultaneous Qualitative and Quantitative (Qual/Quan) approach involves micro flow (20 µL/min) high pressure liquid chromatography (HPLC)/high-resolution mass spectrometry (HRMS) and post-acquisition data processing with Skyline software for profiling numerous GS in biological matrices. The quantitative assay involves reverse-phase liquid chromatography/HRMS and calibration curves using commercially available GS. RESULTS: Protein precipitation resulted in ~60%-80% GS recovery from biological matrices. Direct injection of the extract allowed for quantification of targeted GS in human blood, plasma, and cancer cell lines. The lower limit of detection for the target analytes, GM1, GT1, GD1, spiked into 1% BSA/PBS, ranged from 1 to 10 ng/mL. Human lung cancer cell lines contained variable amounts (1-130 ng/mL) of soluble Fuc-GM1 analogs, potential biomarkers of lung cancer. CONCLUSIONS: A combination of simple extraction and micro-HPLC/HRMS allowed for quantification of GS in human serum and whole blood. Integration of HRMS with Skyline allowed for GS profiling in the same samples using post-acquisition HRMS data without the need for reanalysis. The strategy presented here is expected to play an important role in profiling exploratory GS biomarkers in discovery bioanalytical research.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Gangliosídeos/sangue , Lipidômica/métodos , Espectrometria de Massas/métodos , Biomarcadores/sangue , Linhagem Celular Tumoral , Humanos , Software
2.
Anal Chem ; 92(19): 13525-13531, 2020 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-32926623

RESUMO

Bioanalysis of polar analytes using liquid chromatography-tandem mass spectrometry (LC-MS/MS) remains a significant challenge because of their poor chromatographic retention on the commonly used reversed-phase LC columns and the resulting severe ionization suppression from coeluting matrix components. Here we present a novel approach to perform ultrahigh-throughput and chromatography-free bioanalysis of polar compounds using a prototype acoustic ejection mass spectrometer (AEMS) platform. Previously developed for direct analysis of solid or liquid samples by MS, the open port interface (OPI) has recently been modified and coupled to an acoustic nanoliter dispenser to enable high-speed direct MS analysis from 384-well plates with a reported speed as fast as 0.5 s/sample. Ionization suppression was reduced due to the >1000 fold dilution of the original sample by the carrier solvent in the AE-OPI-MS operation. Taking full advantage of the chromatography-free and suppression-reducing features of this prototype instrument, we successfully demonstrated the ultrahigh-throughput bioanalysis of metformin, a small polar substrate commonly used in high-throughput in vitro transporter inhibition assays in the early ADME profiling space in drug discovery. The AEMS platform achieved a speed of 2.2 s/sample using only 10 nL of sample volume. Similar bioanalytical and biological results from actual assay samples were obtained by AEMS when compared to those obtained by the fastest LC-MS/MS method previously reported, along with a 15-fold speed advantage and ∼500-fold less sample consumption to enable future assay miniaturization. The general applicability of this novel approach to bioanalysis of several classes of polar analytes including ethambutol, isoniazid, ephedrine, and gemcitabine in biological matrices was further demonstrated.


Assuntos
Acústica , Desoxicitidina/análogos & derivados , Efedrina/análise , Etambutol/análise , Ensaios de Triagem em Larga Escala , Isoniazida/análise , Desoxicitidina/análise , Células HEK293 , Humanos , Espectrometria de Massas , Gencitabina
3.
Clin Chem ; 66(2): 282-301, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32040572

RESUMO

Immunoaffinity-mass spectrometry (IA-MS) is an emerging analytical genre with several advantages for profiling and determination of protein biomarkers. Because IA-MS combines affinity capture, analogous to ligand binding assays (LBAs), with mass spectrometry (MS) detection, this platform is often described using the term hybrid methods. The purpose of this report is to provide an overview of the principles of IA-MS and to demonstrate, through application, the unique power and potential of this technology. By combining target immunoaffinity enrichment with the use of stable isotope-labeled internal standards and MS detection, IA-MS achieves high sensitivity while providing unparalleled specificity for the quantification of protein biomarkers in fluids and tissues. In recent years, significant uptake of IA-MS has occurred in the pharmaceutical industry, particularly in the early stages of clinical development, enabling biomarker measurement previously considered unattainable. By comparison, IA-MS adoption by CLIA laboratories has occurred more slowly. Current barriers to IA-MS use and opportunities for expanded adoption are discussed. The path forward involves identifying applications for which IA-MS is the best option compared with LBA or MS technologies alone. IA-MS will continue to benefit from advances in reagent generation, more sensitive and higher throughput MS technologies, and continued growth in use by the broader analytical community. Collectively, the pursuit of these opportunities will secure expanded long-term use of IA-MS for clinical applications.


Assuntos
Cromatografia Líquida/métodos , Imunoensaio/métodos , Espectrometria de Massas em Tandem/métodos , Bioensaio , Biomarcadores/análise , Humanos , Proteínas/análise , Sensibilidade e Especificidade
4.
Anal Biochem ; 602: 113766, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32389692

RESUMO

The S100A1 protein is a target of interest for the treatment of heart failure as it has been previously reported to be depleted in failing cardiomyocytes. A gene therapy approach leading to increased expression levels of the protein directly in the heart could potentially lead to restoration of contractile function and improve overall cell survival. S100A1 is a relatively small soluble protein that is extremely well conserved across species with only a single amino acid difference between the sequences in human and pig, a commonly used pre-clinical model for evaluation of efficacy, biodistribution and safety for cardiac-directed gene therapy approaches. This high homology presents a bioanalytical challenge for the accurate detection and quantitation of both endogenous (pig) and exogenous (human) transduced S100A1 proteins post treatment using a human S100A1 gene therapy in pigs. Here we present a sensitive and selective LC-MS/MS approach that can easily differentiate and simultaneously quantitate both human and pig S100A1 proteins. Additionally, we report on a detailed profiling of S100A1 protein in various pig tissues, a comprehensive evaluation of S100A1 distribution in pig hearts and a comparison to S100A1 levels in human cardiac samples.


Assuntos
Técnicas de Transferência de Genes , Miócitos Cardíacos/química , Proteínas S100/análise , Proteínas S100/genética , Animais , Cromatografia Líquida , Humanos , Miócitos Cardíacos/metabolismo , Proteínas S100/metabolismo , Suínos , Espectrometria de Massas em Tandem
5.
Anal Biochem ; 503: 71-8, 2016 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-27033006

RESUMO

The growing field of biomarker bioanalysis by liquid chromatography mass spectrometry (LC-MS) is challenged with the selection of suitable matrices to construct relevant and valid calibration curves resulting in not only precise but also accurate data. Because surrogate matrices are often employed with the associated concerns about the accuracy of the obtained data, here we present an assay using surrogate analytes in naive biological matrices. This approach is illustrated with the analysis of endogenous bile acids (e-BAs) in serum and plasma using stable isotope-labeled (SIL) analogues as calibration standards to address the matrix concerns. Several deuterated BAs (d-BAs) were used as standards representing respectively grouped e-BAs with structural similarity allowing for the simultaneous bioanalysis of 16 e-BA. The utility of this LC-MS assay employing d-BAs is demonstrated with the analysis of samples resultant of a controlled metabolomics study where a cohort of rats was fed/fasted to investigate the change of e-BAs dependent on food consumption and fasting time.


Assuntos
Ácidos e Sais Biliares/sangue , Ácidos e Sais Biliares/metabolismo , Marcação por Isótopo , Metabolômica , Animais , Ácidos e Sais Biliares/química , Cromatografia Líquida , Humanos , Espectrometria de Massas , Estrutura Molecular , Ratos
6.
Anal Biochem ; 452: 10-2, 2014 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-24534252

RESUMO

L-serine-O-phosphate (L-SOP), the precursor of L-serine, is a potent agonist against the group III metabotropic glutamate receptors (mGluRs) and, thus, is of interest as a potential biomarker for monitoring modulation of neurotransmitter release. So far, no reports are available on the analysis of L-SOP in cerebrospinal fluid (CSF). Here a novel method is presented to determine L-SOP levels in CSF employing precolumn derivatization with (5-N-succinimidoxy-5-oxopentyl)triphenylphosphonium bromide (SPTPP) coupled to liquid chromatography/mass spectrometry (derivatization-LC/MS, d-LC/MS).


Assuntos
Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Fosfosserina/líquido cefalorraquidiano , Fosfosserina/química , Compostos Organofosforados/química , Succinimidas/química
7.
Rapid Commun Mass Spectrom ; 28(13): 1535-43, 2014 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-24861605

RESUMO

RATIONALE: Liquid chromatography/tandem mass spectrometry (LC/MS/MS) assays are increasingly being used for absolute quantitation of proteins due to high specificity and low cost. However, the major challenge for the LC/MS method is insufficient sensitivity. This paper details the strategies developed to maximize the sensitivity from aspects of chromatography, mass spectrometry, and sample preparation to achieve a highly sensitive LC/MS method. METHODS: The method is based on the LC/MS/MS measurement of a surrogate peptide generated from trypsin digestion of interferon-gamma-inducible protein-10 (IP-10). The sample preparation strategy involved selectively extracting IP-10 and removing high-abundance serum proteins through acidified protein precipitation (PPT). It was revealed in this work that these high-abundance serum proteins, if not separated from the protein of interest, could cause significant ionization saturation and high background noise in selected reaction monitoring (SRM), leading to a 100-fold higher lower limit of quantification (LLOQ). RESULTS: Our method demonstrated that the acidified PPT could be optimized to selectively extract the protein of interest with full recovery of 97% to 103%, while the high-abundance serum proteins could be effectively removed with minimal matrix effect of 90% to 93%. For the first time, a highly sensitive LC/MS method with a LLOQ of 31.62 pM for the quantitation of IP-10 has been achieved, which is a 100-fold improvement over the generic method. CONCLUSIONS: The described method offers excellent sensitivity with advantages of being antibody reagent independent and leads to significant cost and time savings. It has been successfully employed to determine both total and free IP-10 levels in human serum samples. This method development strategy may also be applied to other small proteins.


Assuntos
Quimiocina CXCL10/sangue , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Proteínas Sanguíneas/química , Quimiocina CXCL10/química , Formiatos , Humanos , Análise dos Mínimos Quadrados , Sensibilidade e Especificidade , Tripsina
8.
Rapid Commun Mass Spectrom ; 27(16): 1882-6, 2013 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-23857934

RESUMO

RATIONALE: Research on disorders of the central nervous system (CNS) has shown that an imbalance in the levels of specific endogenous neurotransmitters may underlie certain CNS diseases. These alterations in neurotransmitter levels may provide insight into pathophysiology, but can also serve as disease and pharmacodynamic biomarkers. To measure these potential biomarkers in vivo, the relevant sample matrix is cerebrospinal fluid (CSF), which is in equilibrium with the brain's interstitial fluid and circulates through the ventricular system of the brain and spinal cord. Accurate analysis of these potential biomarkers can be challenging due to low CSF sample volume, low analyte levels, and potential interferences from other endogenous compounds. METHODS: A protocol has been established for effective method development of bioanalytical assays for endogenous compounds in CSF. Database searches and standard-addition experiments are employed to qualify sample preparation and specificity of the detection thus evaluating accuracy and precision. RESULTS: This protocol was applied to the study of the histaminergic neurotransmitter system and the analysis of histamine and its metabolite 1-methylhistamine in rat CSF. CONCLUSIONS: The protocol resulted in a specific and sensitive novel method utilizing pre-column derivatization ultra high performance liquid chromatography/tandem mass spectrometry (UHPLC/MS/MS), which is also capable of separating an endogenous interfering compound, identified as taurine, from the analytes of interest.


Assuntos
Biomarcadores/líquido cefalorraquidiano , Cromatografia Líquida de Alta Pressão/métodos , Histamínicos/líquido cefalorraquidiano , Histamina/líquido cefalorraquidiano , Metilistaminas/líquido cefalorraquidiano , Espectrometria de Massas em Tandem/métodos , Animais , Ratos
9.
Artigo em Inglês | MEDLINE | ID: mdl-35839627

RESUMO

BMS-986205 (Linrodostat) is a small molecule inhibitor of Indoleamine 2, 3 dioxygenase (IDO) that is currently being evaluated in clinical trials for the oral treatment of advanced cancer. Initially, there were concerns regarding possible toxicity following administration, since BMS-986205 undergoes metabolism to form 4-chloroaniline. However, it was later determined that the downstream metabolites of 4-chloroaniline might be a greater concern. To evaluate the potential toxicity of these metabolites, a sensitive LC-MS/MS analytical method was needed to quantify both the parent compound and multiple metabolites. This presented a challenge since the method required the analysis of multiple analytes while still retaining the analytical sensitivity required to support studies. By utilizing a multi-function analytical method, we were able to quantify the necessary analytes using a complex LC-MS/MS-based method including the application of both negative and positive electrospray ionization.


Assuntos
Indolamina-Pirrol 2,3,-Dioxigenase , Espectrometria de Massas em Tandem , Acetamidas , Cromatografia Líquida/métodos , Quinolinas , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos
10.
Rapid Commun Mass Spectrom ; 25(22): 3427-35, 2011 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-22002697

RESUMO

Highly sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS)-based methods have been developed and implemented for the quantitative determination of a number of peptides under evaluation in our Glucagon-Like Peptide-1 (GLP-1) discovery program for the treatment of diabetes. These peptides are GLP-1 receptor agonists. Due to the high potency, low dose, and low exposure of these peptides, LC/MS/MS-based methods with Lower Limits of Quantitation (LLOQs) (low picomolar range) were required to support discovery pharmacokinetic/ pharmacodynamic (PK/PD) studies. Compared with small molecules, many of these peptides posed significant bioanalytical challenges in the development of highly sensitive methods because of their parent signal splitting as a result of the formation of multiply charged states, the unfavorable fragmentation patterns for Selected Reaction Monitoring (SRM) transitions due to the generation of a large number of small mass product ions with relative low intensities, and adsorption issues observed during sample preparation. This paper details the strategies developed to maximize the sensitivity and improve LLOQs from aspects of mass spectrometry, chromatography, and sample preparation. A LLOQ of 10 picomolar was achieved for all of the investigated peptides using 100 µL of mouse plasma. This is a 100-fold improvement on LLOQs over generic LC/MS/MS-based methods when the same sample volume and the same mass spectrometer platform were used. The methods have been implemented in the support of discovery PK/PD studies.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Peptídeo 1 Semelhante ao Glucagon/química , Peptídeos/química , Receptores de Glucagon/agonistas , Espectrometria de Massas em Tandem/métodos , Adsorção , Animais , Calibragem , Cromatografia Líquida de Alta Pressão/normas , Descoberta de Drogas , Receptor do Peptídeo Semelhante ao Glucagon 1 , Camundongos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem/normas
11.
Rapid Commun Mass Spectrom ; 25(2): 281-90, 2011 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-21192023

RESUMO

Recently, we have developed liquid chromatography/tandem mass spectrometry (LC/MS/MS)-based methods for the quantitation of pegylated therapeutic proteins in plasma. The methods are based on the LC/MS/MS detection of a surrogate peptide generated from trypsin digestion of the therapeutic protein. Various parameters related to the bioanalytical methods were evaluated and optimized, including the preparation of calibration standards and quality control samples, sample extraction, internal standard selection and its stage of addition, trypsin digestion, and non-specific binding. In this paper, we report the development of a method for a specific pegylated therapeutic protein and detail the various optimization steps undertaken. Simple extraction of the pegylated therapeutic protein from plasma was achieved via the precipitation of the endogenous proteins in plasma using acidic isopropanol and the resulting supernatant extract was subjected to trypsin digestion. A unique tryptic peptide arising from the pegylated therapeutic protein was used for LC/MS/MS-based detection and quantitation. A protein and a peptide were used as internal standards, with the former added before the sample extraction and the latter after the sample extraction. The method developed is simple, sensitive, specific and rugged, and has been implemented in a high throughput 96-well format to analyze plasma samples from in vivo studies. A required lower limit of quantitation (LLOQ) of 10 ng/mL, expressed in terms of the concentration of the protein drug, was easily achieved.


Assuntos
Proteínas Sanguíneas/análise , Cromatografia Líquida/métodos , Fragmentos de Peptídeos/análise , Preparações Farmacêuticas/análise , Polietilenoglicóis/química , Espectrometria de Massas em Tandem/métodos , 2-Propanol , Animais , Proteínas Sanguíneas/metabolismo , Haplorrinos , Análise dos Mínimos Quadrados , Fragmentos de Peptídeos/metabolismo , Preparações Farmacêuticas/metabolismo , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tripsina/metabolismo
12.
Rapid Commun Mass Spectrom ; 25(9): 1231-40, 2011 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-21488121

RESUMO

The evaluation of interactions between drug candidates and transporters such as P-glycoprotein (P-gp) has gained considerable interest in drug discovery and development. Inhibition of P-gp can be assessed by performing bi-directional permeability studies with in vitro P-gp-expressing cellular model systems such as Caco-2 (human colon carcinoma) cells, using digoxin as a substrate probe. Existing methodologies include either assaying (3)H-digoxin with liquid scintillation counting (LSC) detection or assaying non-labeled digoxin with liquid chromatography-tandem mass spectrometric (LC-MS/MS) analysis at a speed of several minutes per sample. However, it is not feasible to achieve a throughput high enough using these approaches to sustain an early liability screen that generates more than a thousand samples on a daily basis. To address this challenge, we developed an ultrafast (9 s per sample) bioanalytical method for digoxin analysis using RapidFire™, an on-line solid-phase extraction (SPE) system, with MS/MS detection. A stable isotope labeled analog, d3-digoxin, was used as internal standard to minimize potential ionization matrix effect during the RF-MS/MS analysis. The RF-MS/MS method was more than 16 times faster than the LC-MS/MS method but demonstrated similar sensitivity, selectivity, reproducibility, linearity and robustness. P-gp inhibition results of multiple validation compounds obtained with this RF-MS/MS method were in agreement with those generated by both the LC-MS/MS method and the (3)H-radiolabel assay. This method has been successfully deployed to assess P-gp inhibition potential as an important early liability screen for drug-transporter interaction.


Assuntos
Membro 1 da Subfamília B de Cassetes de Ligação de ATP/antagonistas & inibidores , Cromatografia Líquida/métodos , Digoxina/análise , Ensaios de Triagem em Larga Escala/métodos , Espectrometria de Massas em Tandem/métodos , Membro 1 da Subfamília B de Cassetes de Ligação de ATP/metabolismo , Células CACO-2 , Ciclosporina/química , Ciclosporina/farmacologia , Digoxina/química , Digoxina/metabolismo , Descoberta de Drogas/métodos , Descoberta de Drogas/normas , Humanos , Modelos Lineares , Modelos Biológicos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Extração em Fase Sólida , Trítio
13.
Bioanalysis ; 13(3): 147-159, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33543654

RESUMO

Background: Surrogate monoclonal antibodies (mAbs) used in preclinical in vivo studies can be challenging to quantify due to lack of suitable immunoaffinity reagents or unavailability of the mAb protein sequence. Generic immunoaffinity reagents were evaluated to develop sensitive LC-MS/MS assays. Peptides of unknown sequence can be used for selective LC-MS quantification. Results: anti-mouse IgG1 was found to be an effective immunoaffinity reagent, enabling quantification of mouse IgG1 mAbs in mouse serum. Selective peptides of unknown sequence were applied for multiplex LC-MS quantification of two rat mAbs co-dosed in mouse. Conclusion: Generic anti-mouse IgG subtype-specific antibodies can be used to improve assay sensitivity and peptides of unknown sequence can be used to quantify surrogate mAbs when the mAb protein sequence in unavailable.


Assuntos
Anticorpos Monoclonais/sangue , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Animais , Humanos , Camundongos , Ratos
14.
Rapid Commun Mass Spectrom ; 24(22): 3221-9, 2010 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-20972995

RESUMO

Liquid chromatography/tandem mass spectrometry (LC/MS/MS) based on selected reaction monitoring (SRM) is the standard methodology in quantitative analysis of administered xenobiotics in biological samples. Utilizing two SRM channels during positive electrospray ionization (ESI) LC/MS/MS method development for a drug compound containing two basic functional groups, we found that the response ratio (SRM1/SRM2) obtained using an acidic mobile phase was dramatically different from that obtained using a basic mobile phase. This observation is different from the well-established phenomenon of mobile phase affecting the [M+H](+) response, which is directly related to the amount of the [M+H](+) ions produced during the ionization. Results from follow-up work reported herein revealed that the MS/MS fragmentation patterns of four drug or drug-like compounds are affected not only by the pH, but also by the aqueous-organic ratio of the mobile phase and the buffer concentration at a given apparent pH. The observed phenomenon can be explained by invoking that a mixture of [M+H](+) ions of the same m/z value for the analyte is produced that is composed of two or more species which differ only in the site of the proton attachment, which in turn affects their MS/MS fragmentation pattern. The ratio of the different protonated species changes depending on the pH, aqueous-organic ratio, or ionic strength of the mobile phase used. The awareness of the mobile phase dependency of the MS/MS fragmentation pattern of precursor ions of identical m/z value will influence LC/MS/MS-based bioanalytical method development strategies. Specifically, we are recommending that multiple SRM transitions be monitored during mobile phase screening, with the MS/MS parameters used for each SRM optimized for the composition of the mobile phase (pH, organic percentage, and ionic strength) in which the analyte elutes.


Assuntos
Cromatografia Líquida , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem , Fluoroquinolonas/química , Concentração de Íons de Hidrogênio , Compostos Orgânicos/química , Concentração Osmolar , Água/química
15.
Bioanalysis ; 12(20): 1439-1447, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33006478

RESUMO

Aim: There is little information in the literature regarding assays for measuring CDH17 in tissues. Numerous studies indicate overexpression of CDH17 in a variety of diseases including hepatocellular carcinoma, colorectal and gastric cancer. Here we present an immunoaffinity enrichment LC-MS/MS approach for analysis of CDH17 in human tissues, plasma and serum as well as preclinical models. Results: CDH17 levels were measured in colon and ileum tissues from healthy donors and inflamed tissues from patients with Ulcerative Colitus or Crohn's disease. Applicability of the immunocapture LC-MS/MS approach is demonstrated for colon tissues from non-diseased mouse and cynomolgus monkey. Conclusion: The analytical approaches discussed here are suitable for quantitation of CDH17 in various tissues to enable both preclinical and clinical assessment.


Assuntos
Caderinas/metabolismo , Cromatografia de Afinidade/métodos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Humanos
16.
Bioanalysis ; 12(18): 1311-1324, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32945691

RESUMO

Background: S1PR1, a G protein-coupled receptor (GPCR) protein, is a therapeutic target for treatment of autoimmune diseases. As a potential biomarker for drug effect and patient stratification, it is of great significance to measure it in biological samples. However, due to the hydrophobic nature of S1PR1 and the difficulties in extraction and solubilization, as well as low expression levels, quantitative determination of S1PR1 remains challenging. Results: In this work, a peptide immunoaffinity LC-MS/MS method was developed to quantify S1PR1 in biopsy-sized colon samples with an LLOQ of 7.81 pM. Conclusion: Peptide immunoaffinity LC-MS/MS based strategy has achieved the desired sensitivity for low abundance S1PR1, and the same strategy could be applied to quantify S1PR1 in multiple species and other GPCR proteins.


Assuntos
Cromatografia Líquida/métodos , Colo/imunologia , Peptídeos/química , Receptores de Esfingosina-1-Fosfato/imunologia , Espectrometria de Massas em Tandem/métodos , Biópsia , Humanos
17.
Rapid Commun Mass Spectrom ; 23(21): 3457-64, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19813283

RESUMO

QuickQuan is an integrated software package for Thermo Scientific triple quadrupole mass spectrometers that allows users to automate routine operations ranging from method development to data processing. QuickQuan automated optimization of compound-selected reaction monitoring (SRM) transitions by evaluating both positive and negative polarities during an infusion. Whichever mode produces the most intense Q1 scan is then carried to product ion spectra. QuickQuan then writes these SRM methods to a shared network database. The total volume of compound needed is 100 microL infused over approximately 1.6 min. The auto-optimization is carried out in 96-well plates and does not require an operator present. The SRM database was shared between two identical TSQ Quantum mass spectrometers. For data acquisition, QuickQuan automatically created a sequence file complete with a data processing method pre-populated with compound IDs and corresponding SRM transitions. To increase throughput we coupled each Finnigan Quantum with ultra-high-pressure liquid chromatography (uHPLC) accomplished using 4x Ultra Flux quaternary pumps that were designed to handle pressures up to 15 000 psi. The total run time for all analyses was 1.2 min using BEH 1.7 microm particle C18 columns. Further time reductions were realized with sample preparation accomplished using Strata Impact protein precipitation plates which provided an in-well protein crash and 0.20 micron filtering in a one-step process. Pharmacokinetic data turnaround time was significantly improved by combining these three techniques of automated method development with the speed efficiency of uHPLC and a single step in well sample preparation.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Descoberta de Drogas/métodos , Espectrometria de Massas/métodos , Preparações Farmacêuticas/química , Software , Animais , Preparações Farmacêuticas/sangue , Ratos , Análise de Regressão , Sensibilidade e Especificidade
18.
Bioanalysis ; 9(20): 1573-1588, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29072496

RESUMO

AIM: IP-10 is a protein target for the treatment of Crohn's disease. Inhibition of IP-10 by anti-IP-10 mAbs neutralizes its various biological activities. The measurement of free IP-10 suppression as a target engagement biomarker is required for the assessment of drug effect on the target. RESULTS: The development of highly sensitive immunoaffinity-LC-MS/MS assays for quantifying free and total IP-10 in cynomolgus monkey serum is reported for the first time. This paper details strategies for maximizing assay sensitivity by selecting digestion routes, and optimizing immunocapture to achieve full recovery and minimal matrix effect. For the free IP-10 assay, bioanalytical strategies have been established to minimize drug/ligand dissociation. CONCLUSION: The assays have been implemented for target engagement measurement, pharmacokinetic-pharmacodynamic correlation, and human dose projections.


Assuntos
Biomarcadores/sangue , Quimiocina CXCL10/sangue , Cromatografia de Afinidade , Espectrometria de Massas em Tandem , Sequência de Aminoácidos , Animais , Anticorpos Monoclonais/imunologia , Quimiocina CXCL10/genética , Quimiocina CXCL10/imunologia , Cromatografia Líquida de Alta Pressão , Humanos , Ligantes , Macaca fascicularis , Peptídeos/química , Peptídeos/isolamento & purificação , Proteínas Recombinantes/biossíntese , Proteínas Recombinantes/genética , Proteínas Recombinantes/metabolismo , Alinhamento de Sequência
19.
Bioanalysis ; 8(3): 193-204, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26811930

RESUMO

BACKGROUND: Therapeutic protein discovery study highlights the need for the development of quantitative bioanalytical methods for determining the levels of both the therapeutic protein and the target protein, as well. RESULTS: For the quantitation of BMS-986089, both accuracy (99-103%) and precision (2.4-12%) were obtained for the analysis of the surrogate peptide (ITYGGNSPVQEFTVPGR), in addition to the accuracy (100-108%) and precision (0.7-18%) that were obtained for the analysis of the surrogate peptide (VVSVLTVLHQDWLNGK). For Myostatin, accuracy (94-103%) and precision (2.4-14.9%) were obtained for the analysis of the surrogate peptide (IPAMVVDR). CONCLUSION: The developed method was applied to the analysis of samples following dosing of BMS-986089 to mice. This method highlights the potential of LC-MS/MS-based methods to eventually assess in vivo drug-target engagement.


Assuntos
Cromatografia Líquida/métodos , Miostatina/análise , Proteínas Recombinantes de Fusão/análise , Espectrometria de Massas em Tandem/métodos , Sequência de Aminoácidos , Animais , Cromatografia Líquida/economia , Análise Custo-Benefício , Humanos , Imunoglobulina G/análise , Imunoglobulina G/metabolismo , Imunoglobulina G/farmacologia , Imunoglobulina G/uso terapêutico , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Dados de Sequência Molecular , Miostatina/metabolismo , Fragmentos de Peptídeos/análise , Fragmentos de Peptídeos/química , Ratos , Proteínas Recombinantes de Fusão/farmacocinética , Proteínas Recombinantes de Fusão/farmacologia , Proteínas Recombinantes de Fusão/uso terapêutico , Espectrometria de Massas em Tandem/economia , Tripsina/metabolismo
20.
Bioanalysis ; 8(4): 265-74, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26807991

RESUMO

BACKGROUND: A target protein-based affinity extraction LC-MS/MS method was developed to enable plasma level determination following ultralow dosing (0.1-3 µg/kg) of an inhibitor of apoptosis proteins molecule. Methodology & results: Affinity extraction (AE) utilizing immobilized target protein BIR2/BIR3 was used to selectively capture the inhibitor of apoptosis proteins molecule from dog plasma and enable removal of background matrix components. Pretreatment of plasma samples using protein precipitation was found to provide an additional sensitivity gain. A LLOQ of 7.8 pM was achieved by combining protein precipitation with AE. The method was used to support an ultralow dose dog toxicity study. CONCLUSION: AE-LC-MS/MS, utilizing target protein, is a highly sensitive methodology for small molecule quantification with potential for broader applicability.


Assuntos
Análise Química do Sangue/métodos , Fracionamento Químico/métodos , Cromatografia Líquida/métodos , Proteínas Inibidoras de Apoptose/antagonistas & inibidores , Isoquinolinas/análise , Limite de Detecção , Oligopeptídeos/análise , Bibliotecas de Moléculas Pequenas/análise , Espectrometria de Massas em Tandem/métodos , Animais , Cães , Feminino , Humanos , Proteínas Imobilizadas/antagonistas & inibidores , Proteínas Imobilizadas/química , Proteínas Inibidoras de Apoptose/química , Isoquinolinas/química , Isoquinolinas/farmacologia , Masculino , Oligopeptídeos/química , Oligopeptídeos/farmacologia , Bibliotecas de Moléculas Pequenas/química , Bibliotecas de Moléculas Pequenas/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA