Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-37995962

RESUMO

OBJECTIVE: This study aimed to assess aneurysm sac dynamics and its prognostic significance following fenestrated and branched endovascular aneurysm repair (F/BEVAR). METHODS: Patients undergoing F/BEVAR for degenerative complex aortic aneurysm from 2008 to 2020 at two large vascular centres with two imaging examinations (30 day and one year) were included. Patients were categorised as regression and non-regression, determined by the proportional volume change (> 5%) at one year compared with 30 days. All cause mortality and freedom from graft related events were assessed using Kaplan-Meier methods. Factors associated with non-regression at one year and aneurysm sac volume over time were examined for FEVAR and BEVAR independently using multivariable logistic regression and linear mixed effects modelling. RESULTS: One hundred and sixty-five patients were included: 122 FEVAR, of whom 34% did not regress at one year imaging (20% stable, 14% expansion); and 43 BEVAR, of whom 53% failed to regress (26% stable, 28% expansion). Following F/BEVAR, after risk adjusted analysis, non-regression was associated with higher risk of all cause mortality within five years (hazard ratio [HR] 2.56, 95% confidence interval [CI] 1.09 - 5.37; p = .032) and higher risk of graft related events within five years (HR 2.44, 95% CI 1.10 - 5.26; p = .029). Following multivariable logistic regression, previous aortic repair (odds ratio [OR] 2.56, 95% CI 1.11 - 5.96; p = .029) and larger baseline aneurysm diameter (OR/mm 1.04, 95% CI 1.00 - 1.09; p = .037) were associated with non-regression at one year, whereas smoking history was inversely associated with non-regression (OR 0.21, 95% CI 0.04 - 0.96; p = .045). Overall following FEVAR, aneurysm sac volume decreased significantly up to two years (baseline vs. two year, 267 [95% CI 250 - 285] cm3vs. 223 [95% CI 197 - 248] cm3), remaining unchanged thereafter. Overall following BEVAR, aneurysm sac volume remained stable over time. CONCLUSION: Like infrarenal EVAR, non-regression at one year imaging is associated with higher five year all cause mortality and graft related events risks after F/BEVAR. Following FEVAR for juxtarenal aortic aneurysm, aneurysm sacs generally displayed regression (66% at one year), whereas after BEVAR for thoraco-abdominal aortic aneurysm, aneurysm sacs displayed a concerning proportion of growth at one year (28%), potentially suggesting a persistent risk of rupture and consequently requiring intensified surveillance following BEVAR. Future studies will have to elucidate how to improve sac regression following complex EVAR, and whether the high expansion risk after BEVAR is due to advanced disease extent.

2.
Vasc Med ; 28(5): 433-442, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37395286

RESUMO

BACKGROUND: Surveillance programs in abdominal aortic aneurysms (AAA) are mainly based on imaging and leave room for improvement to timely identify patients at risk for AAA growth. Many biomarkers are dysregulated in patients with AAA, which fuels interest in biomarkers as indicators of disease progression. We examined associations of 92 cardiovascular disease (CVD)-related circulating biomarkers with AAA and sac volume. METHODS: In a cross-sectional analysis, we separately investigated (1) 110 watchful waiting (WW) patients (undergoing periodic surveillance imaging without planned intervention) and (2) 203 patients after endovascular aneurysm repair (EVAR). The Cardiovascular Panel III (Olink Proteomics AB, Sweden) was used to measure 92 CVD-related circulating biomarkers. We used cluster analyses to investigate protein-based subphenotypes, and linear regression to examine associations of biomarkers with AAA and sac volume on CT scans. RESULTS: Cluster analyses revealed two biomarker-based subgroups in both WW and EVAR patients, with higher levels of 76 and 74 proteins, respectively, in one subgroup versus the other. In WW patients, uPA showed a borderline significant association with AAA volume. Adjusting for clinical characteristics, there was a difference of -0.092 (-0.148, -0.036) loge mL in AAA volume per SD uPA. In EVAR patients, after multivariable adjustment, four biomarkers remained significantly associated with sac volume. The mean effects on sac volume per SD difference were: LDLR: -0.128 (-0.212, -0.044), TFPI: 0.139 (0.049, 0.229), TIMP4: 0.110 (0.023, 0.197), IGFBP-2: 0.103 (0.012, 0.194). CONCLUSION: LDLR, TFPI, TIMP4, and IGFBP-2 were independently associated with sac volume after EVAR. Subgroups of patients with high levels of the majority of CVD-related biomarkers emphasize the intertwined relationship between AAA and CVD.ClinicalTrials.gov Identifier: NCT03703947.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Doenças Cardiovasculares , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Proteína 2 de Ligação a Fator de Crescimento Semelhante à Insulina , Doenças Cardiovasculares/etiologia , Estudos Transversais , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Resultado do Tratamento , Fatores de Risco , Estudos Retrospectivos
3.
J Endovasc Ther ; 28(1): 146-156, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33025867

RESUMO

PURPOSE: To compare changes in abdominal aortic aneurysm (AAA) sac volume between endovascular aneurysm repairs (EVAR) performed for ruptured (rEVAR) vs intact (iEVAR) AAAs and to determine the impact of early volume shrinkage on future complications. MATERIALS AND METHODS: A retrospective analysis was performed of all patients undergoing standard infrarenal EVAR from 2002 to 2016 at a tertiary referral institution. Only patients with degenerative AAAs and with 30-day and 1-year computed tomography angiography (CTA) imaging were included. Early sac shrinkage was defined as a volume sac reduction >10% between the first (<30-day) and the 1-year CTA. The primary endpoint was to compare AAA sac volume changes between patients undergoing rEVAR (n=51; mean age 71.0±8.5 years; 46 men) vs iEVAR (n=393; mean age 72.3±7.5 years; 350 men). Results are reported as the mean difference with the interquartile range (IQR Q1, Q3). The secondary endpoint was freedom from aneurysm-related complications after 1 year as determined by regression analysis; the results are presented as the hazard ratio (HR) and 95% confidence interval (CI). RESULTS: At baseline, the rEVAR group had larger aneurysms (p<0.001) and shorter (p<0.001) and more angulated (p=0.028) necks. Aneurysm sac volume decreased more in the rEVAR group during the first year [-26.3% (IQR -38.8%, -12.5%)] vs the iEVAR group [-11.9% (IQR -27.5%, 0); p<0.001]. However, after the first year, the change in sac volume was similar between the groups [-3.8% (IQR -32.9%, 31.9%) for rEVAR and -1.5% (IQR -20.9%, 13.6%) for iEVAR, p=0.74]. Endoleak occurrence during follow-up was similar between the groups. In the overall population, patients with early sac shrinkage had a lower incidence of complications after the 1-year examination (adjusted HR 0.59, 95% CI 0.39 to 0.89, p=0.01). CONCLUSION: EVAR patients treated for rupture have more pronounced aneurysm sac shrinkage compared with iEVAR patients during the first year after EVAR. Patients presenting with early shrinkage are less likely to encounter late complications. These parameters may be considered when tailoring surveillance protocols.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
Eur J Vasc Endovasc Surg ; 62(4): 561-568, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34456118

RESUMO

OBJECTIVE: The aim of this study was to investigate the association between post-implantation syndrome (PIS) and long term outcomes, with emphasis on cardiovascular prognosis. METHODS: One hundred and forty-nine consecutive patients undergoing EVAR in a tertiary institution were previously included in a study investigating the risk factors and short term consequences of PIS (defined as tympanic temperature ≥ 38°C and CRP > 10 mg/L, after excluding complications with an effect on inflammatory markers). This study was based on a prospectively maintained database. Survival status was derived from inquiry of civil registry database information and causes of death from the Dutch Central Bureau of Statistics. The primary endpoint was cardiovascular events. Secondary endpoints were overall and specific cause mortality (cardiovascular, ischaemic heart disease, AAA, and cancer related mortality). Aneurysm sac dynamics and occurrence of endoleaks were also analysed. Survival estimates were obtained using Kaplan-Meier plots and a multivariable model was constructed to correct for confounders. RESULTS: The PIS incidence was 39% (58/149). At the time of surgery, patients had a mean age of 73 ± 7 years and were predominantly male. There were no baseline differences between the PIS and non-PIS groups. The median follow up was 6.4 years (3.2 - 8.3), similar in both groups (p = .81). There was no difference in cardiovascular events for PIS and non-PIS patients (p = .63). However, Kaplan-Meier plots suggest a trend towards a higher rate of cardiovascular events in PIS patients during the first years: freedom from cardiovascular events at one year was 94% vs. 89% and at three years 90% vs. 82%. No differences were found in overall and specific cause mortality. There was a higher rate of type II endoleaks for non-PIS patients (28% vs. 9%, p = .005). Sac dynamics were similar in both groups. CONCLUSION: The results suggest that PIS is not associated with a statistically significantly higher risk of cardiovascular events. PIS had no impact on mortality. Lastly, PIS patients had fewer type II endoleaks, but sac dynamics were analogous.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Doenças Cardiovasculares/epidemiologia , Procedimentos Endovasculares/efeitos adversos , Síndrome de Resposta Inflamatória Sistêmica/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Implante de Prótese Vascular/mortalidade , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/mortalidade , Bases de Dados Factuais , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Incidência , Masculino , Países Baixos/epidemiologia , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Síndrome de Resposta Inflamatória Sistêmica/diagnóstico , Síndrome de Resposta Inflamatória Sistêmica/mortalidade , Fatores de Tempo , Resultado do Tratamento
5.
Eur J Vasc Endovasc Surg ; 62(1): 26-35, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34090782

RESUMO

OBJECTIVE: Aortic neck dilatation (AND) occurs after endovascular aneurysm repair (EVAR) with self expanding stent grafts (SESs). Whether it continues, ultimately exceeding the endograft diameter leading to abdominal aortic aneurysm (AAA) rupture, remains uncertain. Dynamics, risk factors, and clinical relevance of AND were investigated after EVAR with standard SESs. METHODS: All intact EVAR patients treated from 2000 to 2015 at a tertiary institution were included. Demographic, anatomical, and device related characteristics were investigated as risk factors for AND. Outer to outer diameters were measured at a single standardised aortic level on reconstructed computed tomography (CT) images. RESULTS: A total of 460 patients were included (median follow up 5.2 years, interquartile range [IQR] 3.0, 7.7 years; CT imaging follow up 3.3 years, IQR 1.3, 5.4). Baseline neck diameter was 24 mm (IQR 22, 26) and increased 11.1% (IQR 1.5%, 21.9%) at last CT imaging. Endograft oversizing was 20.0% (IQR 13.6, 28.0). AND was greater during the first year (5.2% [IQR 0, 11.7]) decreasing subsequently (two to four years to 1.4%/year [IQR 0.0, 4.5%], p ≤ .001) and was associated with suprarenal fixation endografts (t value = 7.9, p < .001) and oversizing (t value = 4.4, p < .001). AND exceeding the endograft was 3.5% (95% CI 2.2% - 4.8%) and 14.4% (95% CI 11.0% - 17.8%) at five and eight years, respectively. Excessive AND was associated with baseline neck diameter (OR 1.2/mm, 95% CI 1.05 - 1.41) while the Excluder endograft had a protective effect (OR 0.15, 95% CI 0.04 - 0.58). Excessive AND was associated with type 1A endoleak (HR 3.3, 95% CI 1.1 - 9.7) and endograft migration > 5 mm (HR 3.1, 95% CI 1.4 - 6.9). CONCLUSION: AND after EVAR with SES is associated with endograft oversizing and radial force but decelerates after the first post-operative year. Baseline aortic neck diameter and suprarenal stent bearing endografts were associated with an increased risk of AND beyond nominal stent graft diameter. However, it remains unclear whether patient selection, differences in endograft radial force or the suprarenal stent are accountable for this difference.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/epidemiologia , Dilatação Patológica/epidemiologia , Endoleak/epidemiologia , Procedimentos Endovasculares/efeitos adversos , Migração de Corpo Estranho/epidemiologia , Idoso , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Ruptura Aórtica/etiologia , Aortografia , Angiografia por Tomografia Computadorizada , Dilatação Patológica/diagnóstico , Dilatação Patológica/etiologia , Endoleak/diagnóstico , Endoleak/etiologia , Procedimentos Endovasculares/instrumentação , Feminino , Migração de Corpo Estranho/etiologia , Humanos , Masculino , Pescoço , Estudos Retrospectivos , Fatores de Risco , Stents/efeitos adversos , Resultado do Tratamento
6.
J Vasc Surg ; 71(1): 64-74, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31147134

RESUMO

OBJECTIVE: Many endografts are currently available for standard endovascular repair of infrarenal abdominal aortic aneurysms. Comparison of long-term outcomes between devices might aid in this decision process, but comparative data are scarce. The purpose of this study was to report long-term clinical outcomes of two commercially available endoprosthesis, the Endurant (Medtronic Vascular, Inc, Minneapolis, Minn) and the Excluder (W. L. Gore & Associates, Flagstaff, Ariz) stent grafts. METHODS: Patients undergoing standard endovascular repair from July 2004 to December 2011 in a single institution with the Endurant or the Low-Porosity Excluder endografts were eligible. Only patients treated for intact degenerative abdominal infrarenal aneurysms were included. All measurements were performed on center-lumen line reconstructions obtained on dedicated software. The primary end point was primary clinical success, defined as clinical success without the need for an additional or secondary surgical or endovascular procedure. Neck-related events (a composite of type IA endoleak, neck-related secondary intervention, or migration of >5 mm), neck morphology changes, renal function, and overall survival were secondary end points. RESULTS: The study included 277 patients (156 Endurants; 121 Excluders). The median follow-up was 5.8 years (range, 0.1-12.4 years) and did not differ between groups (P = .18). Patients treated with the Endurant stent graft had wider (neck diameter of >28 mm, 27.3% vs 1.7% [P < .001]; neck diameter of 27 mm, [interquartile range (IQR), 24-29 mm] for Endurant and 24 mm [IQR, 22-25 mm] for Excluder; P < .001) and more angulated necks (ß-angle of >60°, 26.7% vs 12.5%; P = .004). Oversizing was greater in the Endurant group (16% [IQR, 12%-22%] vs 13% [IQR, 8%-17%], respectively; P < .001). Patients were treated outside device instructions for use regarding proximal neck: 16.7% in the Endurant and 17.3% in the Excluder group (P = .720). The 7-year primary clinical success was 54.7% for the Endurant and 58.1% for the Excluder groups (P = .53). Freedom from neck-related events at 7 years was 76.7% for the Endurant and 78.8% for Excluder group (P = .94). The Endurant stent graft (hazard ratio [HR], 2.7; 95% confidence interval [CI], 1.3-5.8; P = .009) was an independent predictor of significant renal function decline. Neck dilatation was greater in Endurant-implanted patients (13% [95% CI, 2%-22%] vs 4% [95% CI, 0%-10%]; P < .001). Overall survival at 7 years was 61.4% in the Endurant and 50.3% (n = 50; standard error, 0.047) in the Excluder group (P = .39). CONCLUSIONS: This study reveals that durable and sustainable results can be obtained with either of these late generation devices. This finding suggests that careful planning and a tailored device selection taking into account the patient's anatomy are more relevant determinants than the graft model itself to obtain clinical success. The Endurant endoprosthesis seems to be associated with a higher rate of neck dilatation and faster decrease in the estimated glomerular filtration rate, but further studies with longer follow-up are necessary to determine the clinical relevance of these findings.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Bases de Dados Factuais , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
7.
J Vasc Surg ; 71(5): 1554-1563.e1, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31677942

RESUMO

OBJECTIVE: Endovascular aneurysm repair (EVAR) became an increasingly preferred modality for abdominal aortic aneurysm (AAA) repair both in elective AAA repair (el-EVAR) and EVAR of a ruptured AAA (r-EVAR) setting. Ruptured AAAs usually have more hostile anatomies and less time for planning. Consequently, more complications may arise after r-EVAR. The purpose of this study was to compare mi-term outcomes between r-EVAR and el-EVAR. METHODS: A retrospective cohort analysis of patients undergoing EVAR from 2000 to 2015 at a tertiary institution was performed. Patients with previous aortic surgery, nonatherosclerotic AAA and isolated iliac aneurysms were excluded. In-hospital casualties or patients who were intraoperatively converted to open repair were also excluded. For the midterm outcome analysis, only patients with at least two postoperative examinations (a 30-day computed tomography scan and a second postoperative examination performed 6 months or later) were considered. The primary end point was freedom from aneurysm-related complications (a composite of type I or III endoleak, aneurysm sac growth, migration of more than 5 mm, device integrity failure, AAA-related death, late postimplant rupture, or AAA-related secondary intervention). Freedom from secondary interventions, neck-related events (defined as a composite of type IA endoleak, migration of more than 5 mm, or preemptive neck-related secondary intervention) and late survival were secondary end points. The impact of device instructions for use (IFU) compliance on neck events was also assessed. RESULTS: The study included 565 patients (65 r-EVAR and 500 el-EVAR). Eighty-two patients were treated outside proximal neck IFU, 13 in the r-EVAR group (21.3%) and 69 (14.5%) in the el-EVAR (P = .16). During the index hospitalization, there were more complications (12.3% vs 3.2%; P = .001) and reinterventions (12.3% vs 2.8%; P < .001) in the r-EVAR group. After discharge, median clinical follow-up time was 4.3 years (interquartile range, 2.1-7.0 years) without differences between both groups. Five-year freedom from AAA-related complications was 53.9% in the r-EVAR group and 65.4% in the el-EVAR (P = .21). In multivariable analysis the r-EVAR group was not at increased risk for late complications (hazard ratio [HR], 0.94; 95% confidence interval [CI], 0.54-1.61; P = .81). Five-year freedom from neck-related events was 74% in r-EVAR and 82% in the el-EVAR group (P = .345). Patients treated outside neck IFU were at greater risk for neck-related events both in r-EVAR (HR, 6.5; 95% CI, 1.8-22.9; P = .004) and el-EVAR group (HR, 2.6; 95% CI, 1.5-4.5; P < .001). Freedom from secondary interventions at 5 years was 63.0% for r-EVAR and 76.9% for el-EVAR (P = .16). Survival at 5 years was 68.8% in the r-EVAR group and 73.3% in the el-EVAR group (P = .30). CONCLUSIONS: Durable and sustainable midterm outcomes were found for both r-EVAR and el-EVAR patients who survived the postoperative period. Patients treated outside the IFU are at greater risk for late complications. Surveillance protocols may be tailored according to individual anatomy and IFU compliance rather than timing of repair.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Causas de Morte , Bases de Dados Factuais , Procedimentos Cirúrgicos Eletivos , Emergências , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Intervalo Livre de Progressão , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
8.
Eur J Vasc Endovasc Surg ; 59(6): 918-927, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32197997

RESUMO

OBJECTIVE: Large aneurysm diameter represents a well known predictor of late complications after endovascular aneurysm repair (EVAR). However, the role of the thrombus free lumen inside the abdominal aortic aneurysm (AAA) sac is not clear. It was hypothesised that greater luminal volume represents a relevant risk factor for late complications after EVAR. METHODS: A retrospective cohort analysis was performed including all patients undergoing EVAR from 2005 to 2016 at a tertiary referral institution. Pre-operative AAA lumen volume was measured in centre lumen line reconstructions and patients were stratified into quartiles according to luminal volume. The primary endpoint was freedom from AAA related complications. Secondary endpoints were freedom from neck events (type 1A endoleak, migration >5 mm or any pre-emptive neck related intervention), iliac related events (type 1B endoleak or pre-emptive iliac related intervention), and overall survival. RESULTS: Four hundred and four patients were included: 101 in the first quartile (Q1; <61 cm3). Patients with higher luminal volumes had wider, shorter, and more angulated proximal necks. There were more ruptured AAAs, more aorto-uni-iliac implanted devices and patients outside neck instructions for use in the 4th quartile. Five year freedom from AAA related complications was 79%, 66%, 58% and 56%, respectively (p = .007). At five years, freedom from neck related events was 86%, 84%, 73%, and 71%, respectively, for the four groups (p = .009), and freedom from iliac related events was 96%, 91%, 88%, and 88%, respectively (p = .335). On multivariable analysis, luminal volume was an independent predictor of late complications (Q4 vs. Q1 - hazard ratio: 1.91, 95% confidence interval 1.01-3.6, p = .046). Overall survival at five years was not affected by lumen volume (p = .75). CONCLUSION: AAA luminal volume represents an important risk factor for AAA related complications. This information may be considered when deciding tailoring surveillance protocols after EVAR. However, larger studies are needed to validate this hypothesis.


Assuntos
Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/patologia , Aortografia , Angiografia por Tomografia Computadorizada , Feminino , Seguimentos , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Período Pré-Operatório , Estudos Prospectivos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Resultado do Tratamento
9.
Vasa ; 49(5): 367-374, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32513067

RESUMO

Background: Patients undergoing carotid endarterectomy (CEA) may suffer from cerebral hypoperfusion during the carotid cross-clamping. Near-infrared spectroscopy cerebral oximetry (NIRS) is a non-invasive method of regional cerebral oxygen saturation measurement reflecting changes in cerebral blood flow during CEA. The main goal of the study was to evaluate the accuracy of the NIRS in detecting cerebral hypoperfusion during CEA under regional anesthesia (RA) and compare it with awake neurological testing. Patients and methods: A prospective observational study of 28 patients that underwent CEA in RA and manifested neurologic deficits, and 28 consecutive controls from a tertiary and referral center, was performed. All patients were monitored with NIRS cerebral oximetry and awake testing as the control technique. Subsequently, operating characteristic curve and Cohen's kappa coefficient were determined to evaluate the reliability of the monitoring test. Results: NIRS presented a sensitivity of 27.3% and a specificity of 89.3% in comparison to awake testing. Receiver operating characteristic (ROC) curve analysis demonstrated that a decrease of at least 20% in cerebral oxygen saturation is the best threshold to infer cerebral hypoperfusion. However, the respective area under the curve (AUROC) was 0.606 (95% CI: 0.456-0.756, P = 0.178) with a calculated Cohen's kappa of 0.179, P = 0.093. Regarding 30-days outcomes, only awake testing has shown significant associations with stroke and postoperative complications (P = 0.043 and P = 0.05), which were higher in patients with post-clamping neurologic deficits. Conclusions: NIRS demonstrated a reduced discriminative capacity for critical cerebral hypoperfusion, and does not seem to add substantial clinical benefits to the awake test.


Assuntos
Anestesia por Condução , Endarterectomia das Carótidas , Isquemia Encefálica , Circulação Cerebrovascular , Humanos , Monitorização Intraoperatória , Oximetria , Oxigênio , Estudos Prospectivos , Reprodutibilidade dos Testes , Espectroscopia de Luz Próxima ao Infravermelho
10.
Eur J Vasc Endovasc Surg ; 67(4): 620, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38040104
13.
Rev Port Cir Cardiotorac Vasc ; 24(3-4): 113, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29701346

RESUMO

INTRODUCTION: The suitability of the proximal and distal landing zones remains one of the main limitations to thoracic endovascular aortic repair. The advent of custom-made scalloped stent grafts widened the endovascular options in some challenging anatomies. METHODS: The authors present three cases of thoracic aortic aneurysm (TAA), with three different hostile anatomies, successfully treated with custom-made scalloped stent grafts. RESULTS: Case1: Male patient, 47 years old, no relevant medical history. Angio-CT revealed a 54mm post- traumatic TAA, extending distally from the origin of the left subclavian artery. Inadequate sealing in Ishimaru zone 2 was evident. The patient was sequentially treated by means of a carotid-subclavian bypass followed by TEVAR with proximal scallop to the left common carotid artery. Proper proximal sealing was obtained. Case2: Male patient, 76 years old, diagnosed with a 65mm diameter TAA, involving the origin of the left subclavian artery. Presence of a bovine trunk, and inadequate landing zone distally to it, were noted. The patient was sequentially treated by means of a carotid-subclavian bypass followed by TEVAR with proximal scallop to the bovine trunk. Proper sealing in Ishimaru zone 2 was granted. Case3: Male patient, 77 years old, multiple comorbidities. Angio-CT revealed a 59,3mm saccular aneurysm of the distal thoracic descending aorta, extending proximally from the origin of the celiac trunk. Good collateralization was observed after celiac trunk occlusion test. Proper distal seal was obtained by means of selective embolization of the celiac trunk followed by TEVAR with distal scallop to the superior mesenteric artery. All procedures were uneventful, with no reported endoleaks, birdbeaks, migrations or re- interventions. There are no reported complications at 1-year follow-up. CONCLUSION: Custom-made scalloped thoracic stentgrafts are an accessible, reproducible and safe therapeutic option when dealing with hostile descending thoracic anatomies, and should be considered as a minimally-invasive effective solution in selected cases.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Animais , Aneurisma da Aorta Torácica/terapia , Aortografia , Prótese Vascular , Bovinos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Stents , Resultado do Tratamento
14.
Am J Physiol Heart Circ Physiol ; 310(1): H4-13, 2016 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-26475584

RESUMO

Preserved ejection fraction heart failure (HFpEF) diagnosis remains controversial, and invasive left ventricular (LV) hemodynamic evaluation and/or exercise testing is advocated by many. The stiffer HFpEF myocardium may show impaired stroke volume (SV) variation induced by fluctuating LV filling pressure during ventilation. Our aim was to investigate spectral transfer function (STF) gain from end-diastolic pressure (EDP) to indexed SV (SVi) in experimental HFpEF. Eighteen-week-old Wistar-Kyoto (WKY) and ZSF1 lean (ZSF1 Ln) and obese rats (ZSF1 Ob) randomly underwent LV open-chest (OC, n = 8 each group) or closed-chest hemodynamic evaluation (CC, n = 6 each group) under halogenate anesthesia and positive-pressure ventilation at constant inspiratory pressure. Beat-to-beat fluctuations in hemodynamic parameters during ventilation were assessed by STF. End-diastolic stiffness (ßi) and end-systolic elastance (Eesi) for indexed volumes were obtained by inferior vena cava occlusion in OC (multibeat) or single-beat method estimates in CC. ZSF1 Ob showed higher EDP spectrum (P < 0.001), higher STF gain between end-diastolic volume and EDP, and impaired STF gain between EDP and SVi compared with both hypertensive ZSF1 Ln and normotensive WKY controls (P < 0.001). Likewise ßi was only higher in ZSF1 Ob while Eesi was raised in both ZSF1 groups. On multivariate analysis ßi and not Eesi correlated with impaired STF gain from EDP to SVi (P < 0.001), and receiver-operating characteristics analysis showed an area under curve of 0.89 for higher ßi prediction (P < 0.001). Results support further clinical testing of STF analysis from right heart catheterization-derived EDP surrogates to noninvasively determined SV as screening/diagnostic tool to assess myocardial stiffness in HFpEF.


Assuntos
Cateterismo Cardíaco , Diástole , Insuficiência Cardíaca/diagnóstico , Respiração , Processamento de Sinais Assistido por Computador , Volume Sistólico , Função Ventricular Esquerda , Animais , Área Sob a Curva , Modelos Animais de Doenças , Ecocardiografia Doppler , Eletrocardiografia , Insuficiência Cardíaca/fisiopatologia , Modelos Cardiovasculares , Análise Multivariada , Valor Preditivo dos Testes , Curva ROC , Ratos Endogâmicos WKY , Ratos Zucker , Respiração Artificial , Fatores de Tempo , Pressão Ventricular
15.
Am J Physiol Heart Circ Physiol ; 311(4): H1004-H1013, 2016 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-27473939

RESUMO

Recent studies suggest right ventricular (RV) stiffness is important in pulmonary hypertension (PH) prognosis. Smaller stroke volume (SV) variation after a certain RV end-diastolic pressure (EDP) respiratory variation as assessed by spectral transfer function (STF) may identify RV stiffness. Our aim was to evaluate RV stiffness in monocrotaline (MCT)-induced PH progression and to validate STF gain between EDP and SV as marker of stiffness. Seven-week-old male Wistar rats randomly injected with 60 mg/kg MCT or vehicle were divided into three groups (n = 12 each) according to cardiac index (CI): controls (Ctrl), preserved CI (MCT pCI), and reduced CI (MCT rCI). All underwent RV pressure-volume (PV) evaluation 24-34 days after MCT, under halogenate anesthesia and constant positive-pressure ventilation. End-diastolic stiffness (ßi), end-systolic elastance (Eesi), arterial elastance for indexed volumes (Eai), and preload recruitable stroke work (PRSW) were obtained and beat-to-beat fluctuations during ventilation assessed by STF. Eai was the strongest determinant of CI, alongside ßi but not PRSW. MCT rCI showed impaired ventricular-vascular coupling (VVC) and higher ßi, along with low end-diastolic pressure (EDP) and stroke volume index (SVi) STF gain, denoting impaired preload reserve. On multivariate analysis ßi and not Eesi correlated with EDP-SVi STF gain (P < 0.001). Receiver-operating characteristics (ROC) curve analysis of EDP-SVi STF gain showed an area under curve of 0.84 for ßi prediction (P = 0.002). Afterload, impaired VVC and RV stiffness are major players in RV failure. RV stiffness can be assessed by STF gain analysis of respiratory fluctuations between EDP and SVi, which may constitute a prognostic tool in PH.


Assuntos
Hipertensão Pulmonar/fisiopatologia , Volume Sistólico , Disfunção Ventricular Direita/fisiopatologia , Pressão Ventricular , Animais , Diástole , Elasticidade , Hipertensão Pulmonar/induzido quimicamente , Masculino , Monocrotalina/toxicidade , Análise Multivariada , Curva ROC , Ratos , Ratos Wistar , Rigidez Vascular
16.
Am J Physiol Heart Circ Physiol ; 308(12): H1556-63, 2015 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-25862827

RESUMO

Inclusion of exercise testing in diagnostic guidelines for heart failure with preserved ejection fraction (HFpEF) has been advocated, but the target population, technical challenges, and underlying pathophysiological complexity raise difficulties to implementation. Hemodynamic stress tests may be feasible alternatives. Our aim was to test Trendelenburg positioning, phenylephrine, and dobutamine in the ZSF1 obese rat model to find echocardiographic surrogates for end-diastolic pressure (EDP) elevation and HFpEF. Seventeen-week-old Wistar-Kyoto, ZSF1 lean, and obese rats (n = 7 each) randomly and sequentially underwent (crossover) Trendelenburg (30°), 5 µg·Kg(-1)·min(-1) dobutamine, and 7.5 µg·Kg(-1)·min(-1) phenylephrine with simultaneous left ventricular (LV) pressure-volume loop and echocardiography evaluation under halogenate anesthesia. Effort testing with maximum O2 consumption (V̇o 2 max) determination was performed 1 wk later. Obese ZSF1 showed lower effort tolerance and V̇o 2 max along with higher resting EDP. Both Trendelenburg and phenylephrine increased EDP, whereas dobutamine decreased it. Significant correlations were found between EDP and 1) peak early filling Doppler velocity of transmitral flow (E) to corresponding myocardial tissue Doppler velocity (E') ratio, 2) E to E-wave deceleration time (E/DT) ratio, and 3) left atrial area (LAA). Diagnostic efficiency of E/DT*LAA by receiver-operating characteristic curve analysis for elevation of EDP above a cut-off of 13 mmHg during hemodynamic stress was high (area under curve, AUC = 0.95) but not higher than that of E/E' (AUC = 0.77, P = 0.15). Results in ZSF1 obese rats suggest that noninvasive echocardiography after hemodynamic stress induced by phenylephrine or Trendelenburg can enhance diagnosis of stable HFpEF and constitute an alternative to effort testing.


Assuntos
Cateterismo Cardíaco , Dobutamina , Ecocardiografia Doppler , Ecocardiografia sob Estresse , Insuficiência Cardíaca/diagnóstico , Hemodinâmica , Fenilefrina , Volume Sistólico , Função Ventricular Esquerda , Animais , Área Sob a Curva , Modelos Animais de Doenças , Tolerância ao Exercício , Estudos de Viabilidade , Decúbito Inclinado com Rebaixamento da Cabeça , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Masculino , Obesidade/complicações , Consumo de Oxigênio , Valor Preditivo dos Testes , Curva ROC , Ratos Endogâmicos WKY , Ratos Zucker , Reprodutibilidade dos Testes , Fatores de Tempo , Pressão Ventricular
17.
Am J Physiol Heart Circ Physiol ; 309(10): H1648-54, 2015 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-26408538

RESUMO

Myocardial stiffness and upward-shifted end-diastolic pressure-volume (P-V) relationship (EDPVR) are the key to high filling pressures in heart failure with preserved ejection fraction (HFpEF). Nevertheless, many patients may remain asymptomatic unless hemodynamic stress is imposed on the myocardium. Whether delayed relaxation induced by pressure challenge may contribute to high end-diastolic pressure (EDP) remains unsettled. Our aim was to assess the effect of suddenly imposed isovolumic afterload on relaxation and EDP, exploiting a highly controlled P-V experimental evaluation setup in the ZSF1 obese rat (ZSF1 Ob) model of HFpEF. Twenty-week-old ZSF1 Ob (n = 12), healthy Wistar-Kyoto rats (WKY, n = 11), and hypertensive ZSF1 lean control rats (ZSF1 Ln, n = 10) underwent open-thorax left ventricular (LV) P-V hemodynamic evaluation under anesthesia with sevoflurane. EDPVR was obtained by inferior vena cava occlusions to assess LV ED chamber stiffness constant ß, and single-beat isovolumic afterload acquisitions were obtained by swift occlusions of the ascending aorta. ZSF1 Ob showed increased ED stiffness, delayed relaxation, as assessed by time constant of isovolumic relaxation (τ), and elevated EDP with normal ejection fraction. Isovolumic afterload increased EDP without concomitant changes in ED volume or heart rate. In isovolumic beats, relaxation was delayed to the extent that time for complete relaxation as predicted by 3.5 × monoexponentially derived τ (τexp) exceeded effective filling time. EDP elevation correlated with reduced time available to relax, which was the only independent predictor of EDP rise in multiple linear regression. Our results suggest that delayed relaxation during pressure challenge is an important contributor to lung congestion and effort intolerance in HFpEF.


Assuntos
Insuficiência Cardíaca Diastólica/fisiopatologia , Hipertensão/fisiopatologia , Volume Sistólico/fisiologia , Disfunção Ventricular Esquerda/fisiopatologia , Animais , Diástole/fisiologia , Modelos Animais de Doenças , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica , Modelos Lineares , Pressão , Ratos , Ratos Endogâmicos WKY
18.
Clin Chim Acta ; 554: 117786, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38246209

RESUMO

BACKGROUND AND AIMS: Abdominal aortic aneurysm (AAA) patients undergo uniform surveillance programs both leading up to, and following surgery. Circulating biomarkers could play a pivotal role in individualizing surveillance. We applied a multi-omics approach to identify relevant biomarkers and gain pathophysiological insights. MATERIALS AND METHODS: In this cross-sectional study, 108 AAA patients and 200 post-endovascular aneurysm repair (post-EVAR) patients were separately investigated. We performed partial least squares regression and ingenuity pathway analysis on circulating concentrations of 96 proteins (92 Olink Cardiovascular-III panel, 4 ELISA-assays) and 199 metabolites (measured by LC-TQMS), and their associations with CT-based AAA/sac volume. RESULTS: The median (25th-75th percentile) maximal diameter was 50.0 mm (46.0, 53.0) in the AAA group, and 55.4 mm (45.0, 64.2) in the post-EVAR group. Correcting for clinical characteristics in AAA patients, the aneurysm volume Z-score differed 0.068 (95 %CI: (0.042, 0.093)), 0.066 (0.047, 0.085) and -0.051 (-0.064, -0.038) per Z-score valine, leucine and uPA, respectively. After correcting for clinical characteristics and orthogonalization in the post-EVAR group, the sac volume Z-score differed 0.049 (0.034, 0.063) per Z-score TIMP-4, -0.050 (-0.064, -0.037) per Z-score LDL-receptor, -0.051 (-0.062, -0.040) per Z-score 1-OG/2-OG and -0.056 (-0.066, -0.045) per Z-score 1-LG/2-LG. CONCLUSIONS: The branched-chain amino acids and uPA were related to AAA volume. For post-EVAR patients, LDL-receptor, monoacylglycerols and TIMP-4 are potential biomarkers for sac volume. Additionally, distinct markers for sac change were identified.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Correção Endovascular de Aneurisma , Estudos Transversais , Proteômica , Resultado do Tratamento , Estudos Retrospectivos , Fatores de Risco
19.
Int Angiol ; 41(5): 372-381, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36053160

RESUMO

INTRODUCTION: Frozen elephant trunk (FET) technique was developed as an alternative to the conventional elephant trunk (cET) procedure for the repair of complex aortic arch pathology. However, short term results between these different procedures are sparsely described. This systematic review with meta-analysis aimed to compare short term outcomes between FET and cET in the repair of aortic arch pathology. EVIDENCE ACQUISITION: PubMed, Web of Science and Scopus electronic databases were searched for studies comparing performance of FET and cET procedures in patients with aortic arch pathology. The primary outcome of interest was early mortality, defined as 30-day or in-hospital mortality. Secondary outcomes were stroke, and spinal cord ischemia (SCI). Meta-analysis utilizing the random-effects model was performed using Review Manager (RevMan) software, version 5.4. EVIDENCE SYNTHESIS: Ten studies, comprising 1481 patients with aortic arch pathology, were included. Meta-analysis demonstrated statistically significant reduction of early mortality (odds ratio [OR], 0.63; 95% CI, 0.41-0.97) in the FET group. For neurologic outcomes, no significant differences were noted in stroke risk between both groups (OR, 1.21; 95% CI, 0.83-1.75), but an increased risk of SCI was present in FET patients (OR, 2.07; 95% CI, 1.05-4.10). CONCLUSIONS: FET appears to be associated with a significant lower early mortality, at costs of greater SCI risk. Larger studies are needed to provide confident recommendations towards preferential use of either procedure.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Isquemia do Cordão Espinal , Acidente Vascular Cerebral , Humanos , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Isquemia do Cordão Espinal/etiologia , Acidente Vascular Cerebral/etiologia
20.
Int Angiol ; 41(1): 63-73, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34236155

RESUMO

INTRODUCTION: Hyperbaric oxygen therapy (HBOT) is increasingly being used in the treatment of as diabetic foot ulcers (DFU). However, definitive evidence regarding its beneficial effects is still scarce. The present systematic review aims to analyze the role of HBOT in the prevention of limb amputation along with improvement of ulcer healing in patients with lower limbs DFU. EVIDENCE ACQUISITION: Three databases were searched: PubMed, Scopus, and ISI Web of Knowledge. The search was enrolled during October 2020. Both titles and abstracts were examined by two independent reviewers. Only randomized controlled trials (RCTs) reporting a comparison between standard DFU treatment and standard treatment associated with HBOT were included. In all studies eligibility was assessed and data regarding studies characteristics, methods and considered outcomes was obtained. Odds ratio (OR) was used to evaluate amputation and complete ulcer healing rates. Percentage of ulcer reduction at two weeks was evaluated using the inverse variance method, and the values were compared using mean difference values. Meta-analysis was done using a fixed-effect model if I2 values were under 50%, and a random-effects model if not. EVIDENCE SYNTHESIS: Eleven RCTs were included, with a total of 668 patients studied. Patients undergoing HBOT had lower risk of amputation (OR 0.53 95% CI 0.32-0.90, I2=31%). No difference was found in minor amputations (OR 0.89 95% CI 0.35-2.24, I2=69%). Regarding, healing rates, HBOT patients had greater chances of ulcer healing (OR 4,00 95% CI 1.54-10.44, I2=70%). It has also shown higher percentage of ulcer area reduction after two weeks of treatment in the HBOT group (mean difference 23.19%; 95% CI 14.86-31.52; I2=0%). CONCLUSIONS: The present review offers evidence that adjuvant HBOT decreases risk of major amputation while promoting wound healing when combined to standard treatment in the management of DFU. These findings may have clinical relevance in a selected group of patients, yet further larger studies are still needed.


Assuntos
Diabetes Mellitus , Pé Diabético , Oxigenoterapia Hiperbárica , Amputação Cirúrgica , Pé Diabético/diagnóstico , Pé Diabético/cirurgia , Humanos , Oxigenoterapia Hiperbárica/efeitos adversos , Ensaios Clínicos Controlados Aleatórios como Assunto , Cicatrização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA