Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Neurooncol ; 163(2): 417-427, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37294422

RESUMO

PURPOSE: There is limited knowledge about the associations between sodium and proton MRI measurements in brain tumors. The purpose of this study was to quantify intra- and intertumoral correlations between sodium, diffusion, and perfusion MRI in human gliomas. METHODS: Twenty glioma patients were prospectively studied on a 3T MRI system with multinuclear capabilities. Three mutually exclusive tumor volumes of interest (VOIs) were segmented: contrast-enhancing tumor (CET), T2/FLAIR hyperintense non-enhancing tumor (NET), and necrosis. Median and voxel-wise associations between apparent diffusion coefficient (ADC), normalized relative cerebral blood volume (nrCBV), and normalized sodium measurements were quantified for each VOI. RESULTS: Both relative sodium concentration and ADC were significantly higher in areas of necrosis compared to NET (P = 0.003 and P = 0.008, respectively) and CET (P = 0.02 and P = 0.02). Sodium concentration was higher in CET compared to NET (P = 0.04). Sodium and ADC were higher in treated compared to treatment-naïve gliomas within NET (P = 0.006 and P = 0.01, respectively), and ADC was elevated in CET (P = 0.03). Median ADC and sodium concentration were positively correlated across patients in NET (r = 0.77, P < 0.0001) and CET (r = 0.84, P < 0.0001), but not in areas of necrosis (r = 0.45, P = 0.12). Median nrCBV and sodium concentration were negatively correlated across patients in areas of NET (r=-0.63, P = 0.003). Similar associations were observed when examining voxel-wise correlations within VOIs. CONCLUSION: Sodium MRI is positively correlated with proton diffusion MRI measurements in gliomas, likely reflecting extracellular water. Unique areas of multinuclear MRI contrast may be useful in future studies to understand the chemistry of the tumor microenvironment.


Assuntos
Neoplasias Encefálicas , Glioma , Humanos , Prótons , Imageamento por Ressonância Magnética , Glioma/diagnóstico por imagem , Glioma/patologia , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Imagem de Difusão por Ressonância Magnética , Perfusão , Necrose , Microambiente Tumoral
2.
Eur Radiol ; 33(4): 2895-2904, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36422648

RESUMO

OBJECTIVES: To assess the accuracy, repeatability, and reproducibility of T1 and T2 relaxation time measurements by three-dimensional magnetic resonance fingerprinting (3D MRF) using various dictionary resolutions. METHODS: The ISMRM/NIST phantom was scanned daily for 10 days in two 3 T MR scanners using a 3D MRF sequence reconstructed using four dictionaries with varying step sizes and one dictionary with wider ranges. Thirty-nine healthy volunteers were enrolled: 20 subjects underwent whole-brain MRF scans in both scanners and the rest in one scanner. ROI/VOI analyses were performed on phantom and brain MRF maps. Accuracy, repeatability, and reproducibility metrics were calculated. RESULTS: In the phantom study, all dictionaries showed high T1 linearity to the reference values (R2 > 0.99), repeatability (CV < 3%), and reproducibility (CV < 3%) with lower linearity (R2 > 0.98), repeatability (CV < 6%), and reproducibility (CV ≤ 4%) for T2 measurement. The volunteer study demonstrated high T1 reproducibility of within-subject CV (wCV) < 4% by all dictionaries with the same ranges, both in the brain parenchyma and CSF. Yet, reproducibility was moderate for T2 measurement (wCV < 8%). In CSF measurement, dictionaries with a smaller range showed a seemingly better reproducibility (T1, wCV 3%; T2, wCV 8%) than the much wider range dictionary (T1, wCV 5%; T2, wCV 13%). Truncated CSF relaxometry values were evident in smaller range dictionaries. CONCLUSIONS: The accuracy, repeatability, and reproducibility of 3D MRF across various dictionary resolutions were high for T1 and moderate for T2 measurements. A lower-resolution dictionary with a well-defined range may be adequate, thus significantly reducing the computational load. KEY POINTS: • A lower-resolution dictionary with a well-defined range may be sufficient for 3D MRF reconstruction. • CSF relaxation times might be underestimated due to truncation by the upper dictionary range. • Dictionary with a higher upper range might be advisable, especially for CSF evaluation and elderly subjects whose perivascular spaces are more prominent.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Idoso , Processamento de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Encéfalo/diagnóstico por imagem , Imagens de Fantasmas
3.
Eur Radiol ; 32(8): 5392-5401, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35298680

RESUMO

OBJECTIVES: To assess the feasibility of low-dose contrast-enhanced four-dimensional (4D) time-resolved angiography with stochastic trajectories (TWIST) with iterative reconstruction (hereafter IT-TWIST-MRA) covering the whole brain and to compare IT-TWIST-MRA and TWIST-MRA with reference to digital subtraction angiography (DSA) in the evaluation of arteriovenous shunts (AVS). METHODS: Institutional Review Board approval was obtained for this observational study, and the requirement for written informed consent was waived. Twenty-nine patients with known AVS underwent TWIST-MRA on a 3-T MRI scanner, using low-dose injection (0.02 mmol/kg) of gadolinium-based contrast agent (GBCA) with each of Fourier and iterative reconstruction between September 2016 and October 2019. Visual evaluation of image quality was conducted for delineation of (a) the normal cerebral arteries and veins and (b) AVS feeder, shunt, and drainer vessels. Region-of-interest evaluation was conducted to evaluate bolus sharpness and baseline signal fluctuation in the signal intensity of the cerebral vessels. We compared the detection of AVS between TWIST-MRA and IT-TWIST-MRA. The paired-samples Wilcoxon test was used to test the differences between TWIST-MRA and IT-TWIST-MRA. RESULTS: Visualization scores for normal vasculature and AVS angioarchitecture were significantly better for images produced using IT-TWIST-MRA than those using TWIST-MRA. Peak signal and the enhancement slope of the time-intensity curve were significantly higher for IT-TWIST-MRA than for TWIST-MRA, except for the superior sagittal sinus (SSS). Baseline intensity fluctuation was significantly lower for IT-TWIST-MRA than for TWIST, except for SSS. CONCLUSIONS: IT-TWIST-MRA yields clinically feasible 4D MR-DSA images and delineates AVS even with low-dose GBCA. KEY POINTS: • Iterative reconstruction significantly improves the image quality of TWIST-MRA covering the whole brain. • The short temporal footprint and denoising effect of iterative reconstruction enhances the quality of 4D-MRA. • IT-TWIST-MRA yields clinically feasible images of AVS with low-dose GBCA.


Assuntos
Aumento da Imagem , Angiografia por Ressonância Magnética , Angiografia Digital , Encéfalo , Meios de Contraste/farmacologia , Humanos , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X
4.
Mov Disord ; 36(4): 874-882, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33314293

RESUMO

BACKGROUND: Neuromelanin-sensitive magnetic resonance imaging techniques have been developed but currently require relatively long scan times. The aim of this study was to assess the ability of black-blood delay alternating with nutation for tailored excitation-prepared T1-weighted variable flip angle turbo spin echo (DANTE T1-SPACE), which provides relatively high resolution with a short scan time, to visualize neuromelanin in the substantia nigra pars compacta (SNpc). METHODS: Participants comprised 49 healthy controls and 25 patients with Parkinson's disease (PD). Contrast ratios of SNpc and hyperintense SNpc areas, which show pixels brighter than thresholds, were assessed between DANTE T1-SPACE and T1-SPACE in healthy controls. To evaluate the diagnostic ability of DANTE T1-SPACE, the contrast ratios and hyperintense areas were compared between healthy and PD groups, and receiver operating characteristic analyses were performed. We also compared areas under the curve (AUCs) between DANTE T1-SPACE and the previously reported gradient echo neuromelanin (GRE-NM) imaging. Each analysis was performed using original images in native space and images transformed into Montreal Neurological Institute space. Values of P < 0.05 were considered significant. RESULTS: DANTE T1-SPACE showed significantly higher contrast ratios and larger hyperintense areas than T1-SPACE. On DANTE T1-SPACE, healthy controls showed significantly higher contrast ratios and larger hyperintense areas than patients with PD. Hyperintense areas in native space analysis achieved the best AUC (0.94). DANTE T1-SPACE showed AUCs as high as those of GRE-NM. CONCLUSIONS: DANTE T1-SPACE successfully visualized neuromelanin of the SNpc and showed potential for evaluating PD. © 2020 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society.


Assuntos
Melaninas , Doença de Parkinson , Humanos , Imageamento por Ressonância Magnética , Doença de Parkinson/diagnóstico por imagem , Parte Compacta da Substância Negra , Substância Negra
5.
J Magn Reson Imaging ; 53(4): 1151-1161, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33067897

RESUMO

BACKGROUND: Hypothalamic-pituitary-thyroid (HPT) maturation has not been extensively evaluated using neonatal MRI, even though both structures are visualized on MRI. HYPOTHESIS: That signal intensity and volume of pituitary and thyroid (T) glands on MRI in neonates may be interrelated. STUDY TYPE: Retrospective. SUBJECTS: In all, 102 participants. FIELD STRENGTH/SEQUENCE: 3.0T, T1 -weighted pointwise encoding time reduction with radial acquisition (PETRA). ASSESSMENT: The volume of interest of the anterior pituitary (AP), posterior pituitary (PP), and T on MRI were defined on T1 -PETRA by two radiologists, and volumes of AP (AP_vol) and thyroid (T_vol) were calculated. Gestational age (GA), chronological age (CA), GA+CA, birth weight (BW), and thyroid function were recorded. Mean and maximum signal intensities of AP, PP, and T were normalized using signals from the pons and spinal cord as follows: signal ratio of anterior pituitary/pons (AP/pons), signal ratio of posterior pituitary/pons (PP/pons), and signal ratio of thyroid/cord (T/cord) T/cord, respectively. STATISTICAL TESTS: Correlations between signal intensity and volume measures and GA, CA, GA+CA, and BW were assessed using Pearson's correlation coefficient or Spearman's rank correlation coefficient. Thyroid function analysis and Tmean /cord, Tmax /cord, and T_vol were evaluated using the Steel-Dwass test. RESULTS: APmean /pons correlated positively with GA (ρ = 0.62, P < 0.001) and BW (ρ = 0.74, P < 0.001), and negatively with CA (ρ = -0.86, P < 0.001) and GA+CA (ρ = -0.46, P < 0.001). PPmean /pons correlated positively with GA (ρ = 0.49, P < 0.001) and BW (ρ = 0.63, P < 0.001), and negatively with CA (ρ = -0.70, P < 0.001) and GA+CA (r = -0.38, P < 0.001). Tmean /cord correlated positively with GA (ρ = 0.48, P < 0.001) and BW (ρ = 0.55, P < 0.001), and negatively with CA (ρ = -0.59, P < 0.001) and GA+CA (ρ = -0.22, P = 0.03). AP_vol correlated positively with GA (ρ = 0.68, P < 0.001) and BW (ρ = 0.73, P < 0.001), and negatively with CA (ρ = -0.72, P < 0.001). T_vol correlated positively with GA (ρ = 0.50, P < 0.001) and BW (ρ = 0.61, P < 0.001), and negatively with CA (ρ = -0.54, P < 0.001). APmean /pons correlated positively with Tmean /cord (ρ = 0.61, P < 0.001). DATA CONCLUSION: Signal and volume of pituitary and thyroid glands correlated positively with GA and BW, and negatively with CA in neonates. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY STAGE: 5.


Assuntos
Imageamento por Ressonância Magnética , Glândula Tireoide , Peso ao Nascer , Idade Gestacional , Humanos , Lactente , Recém-Nascido , Estudos Retrospectivos , Glândula Tireoide/diagnóstico por imagem
6.
Radiology ; 294(3): 600-609, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31909699

RESUMO

Background Quantitative susceptibility mapping (QSM) is used to differentiate between calcification and iron deposits. Few studies have examined the relationship between CT attenuation values and magnetic susceptibility in such materials. Purpose To assess the relationship among metal concentration, CT attenuation values, and magnetic susceptibility in paramagnetic and diamagnetic phantoms, and the relationship between CT attenuation values and susceptibility in brain structures that have paramagnetic or diamagnetic properties. Materials and Methods In this retrospective study, CT and MRI with QSM were performed in gadolinium and calcium phantoms, patients, and healthy volunteers between June 2016 and September 2017. In the phantom study, we evaluated correlations among metal concentration, CT attenuation values, and susceptibility. In the human study, Pearson and Spearman correlations were performed to assess the relationship between CT attenuation values and susceptibility in regions of interest placed in the globus pallidus (GP), putamen, caudate nucleus, substantia nigra, red nucleus, dentate nucleus, choroid plexus, and hemorrhagic and calcified lesions. Results Eighty-four patients (mean age, 64.8 years ± 19.6; 49 women) and 20 healthy volunteers (mean age, 72.0 years ± 7.6; 11 men) were evaluated. In the phantoms, strong linear correlations were identified between gadolinium concentration and CT and MRI QSM values (R 2 = 0.95 and 0.99, respectively; P < .001 for both) and between calcium concentration and CT and MRI QSM values (R 2 = 0.89 [P = .005] and R 2 = 0.98 [P < .001], respectively). In human studies, positive correlations between CT attenuation values and susceptibility were observed in the GP (R 2 = 0.52, P < .001) and in hemorrhagic lesions (R 2 = 0.38, P < .001), and negative correlations were found in the choroid plexus (R 2 = 0.53, P < .001) and in calcified lesions (R 2 = 0.38, P = .009). Conclusion CT attenuation values showed a positive correlation with susceptibility in the globus pallidus and hemorrhagic lesions and negative correlation in the choroid plexus and calcified lesions. © RSNA, 2020 Online supplemental material is available for this article.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Encefalopatias/diagnóstico por imagem , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Estudos Retrospectivos
7.
J Magn Reson Imaging ; 51(5): 1497-1506, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31625655

RESUMO

BACKGROUND: Time-resolved angiography with interleaved stochastic trajectories (TWIST) is a keyhole imaging with frequent sampling of central k-space data and view-sharing for the peripheral k-space of dynamic phases. IT-TWIST is a technique to reconstruct images with a smaller temporal footprint using the same raw data obtained with TWIST by iterative reconstruction. PURPOSE: To compare image quality between TWIST and IT-TWIST in 3D pituitary DCE-MRI. STUDY TYPE: Retrospective observation study. POPULATION: Fifty-one patients (23 men, 28 women) who underwent 3D pituitary DCE-MRI using TWIST between July 2016 and April 2017. FIELD STRENGTH/SEQUENCE: 3T/TWIST and IT-TWIST. ASSESSMENT: Visual evaluation was conducted for image quality of delineation of the pituitary stalk and posterior lobe during the early arterial phase, cerebral white matter near the sella turcica, and the mass lesion. Bolus sharpness of the pituitary stalk, posterior lobe, and bilateral cavernous sinus was evaluated on the enhancement slope map calculated from TWIST and IT-TWIST. Temporal stability of intensity of the nonenhanced area was evaluated on temporal standard deviation (SD) maps calculated from TWIST and IT-TWIST. STATISTICAL TESTS: Paired t-test or Wilcoxon rank-sum test was used to test the differences between TWIST and IT-TWIST in both visual evaluation and region of interest evaluation. RESULTS: Scores of visual evaluations for IT-TWIST were significantly better than those for TWIST (P < 0.001) in all items. Enhancement slope for IT-TWIST was significantly higher than that for TWIST in posterior lobe, and right and left cavernous sinus (P < 0.001). Temporal SD for IT-TWIST was significantly lower than that for TWIST in all items, with statistical significance (P < 0.001). DATA CONCLUSION: IT-TWIST yielded better visualization, and better enhancement slope, and less temporal SD compared with TWIST in 3D pituitary DCE-MRI. Evidence Level: 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2020;51:1497-1506.


Assuntos
Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Angiografia , Meios de Contraste , Feminino , Humanos , Aumento da Imagem , Masculino , Hipófise/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos
8.
MAGMA ; 33(6): 783-791, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32248322

RESUMO

OBJECTIVE: To compare the absolute values and repeatability of magnetic resonance fingerprinting (MRF) with 3000 and 1500 echoes/slice acquired in 41 s and 20 s (MRF3k and MRF1.5k, respectively). MATERIALS AND METHODS: MRF3k and MRF1.5k scans based on fast imaging with steady precession (FISP) were conducted using a 3 T scanner. Inter-scan agreement and intra-scan repeatability were investigated in 41 and 28 subjects, respectively. Region-of-interest (ROI) analysis was conducted on T1 values of MRF3k by two raters, and their agreement was evaluated using intraclass correlation coefficients (ICCs). Between MRF3k and MRF1.5k, differences in T1 and T2 values and inter-measurement correlation coefficients (CCs) were investigated. Intra-measurement repeatability was evaluated using coefficients of variation (CVs). A p value < 0.05 was considered statistically significant. RESULTS: The ICCs of ROI measurements were 0.77-0.96. Differences were observed between the two MRF scans, but the CCs of the overall ROIs were 0.99 and 0.97 for the T1 and T2 values, respectively. The mean and median CVs of repeatability were equal to or less than 1.58% and 3.13% in each of the ROIs for T1 and T2, respectively; there were some significant differences between MRF3k and MRF1.5k, but they were small, measuring less than 1%. DISCUSSION: Both MRF3k and MRF1.5k had high repeatability, and a strong to very strong correlation was observed, with a trend toward slightly higher values in MRF1.5k.


Assuntos
Imageamento por Ressonância Magnética , Aceleração , Humanos , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Reprodutibilidade dos Testes , Voluntários
9.
Artigo em Inglês | MEDLINE | ID: mdl-38719607

RESUMO

BACKGROUND AND PURPOSE: Resting-state functional MRI (rs-fMRI) can be used to estimate functional connectivity (FC) between different brain regions, which may be of value for identifying cognitive impairment in patients with brain tumors. Unfortunately, neither rs-fMRI nor neurocognitive assessments are routinely assessed clinically, mostly due to limitations in examination time and cost. Since DSC perfusion MRI is often used clinically to assess tumor vascularity and similarly uses a gradient-echo-EPI sequence for T2*-sensitivity, we theorized a "pseudo-rs-fMRI" signal could be derived from DSC perfusion to simultaneously quantify FC and perfusion metrics, and these metrics can be used to estimate cognitive impairment in patients with brain tumors. MATERIALS AND METHODS: Twenty-four consecutive patients with gliomas were enrolled in a prospective study that included DSC perfusion MRI, resting-sate functional MRI (rs-fMRI), and neurocognitive assessment. Voxelwise modeling of contrast bolus dynamics during DSC acquisition was performed and then subtracted from the original signal to generate a residual "pseudo-rs-fMRI" signal. Following the preprocessing of pseudo-rs-fMRI, full rs-fMRI, and a truncated version of the full rs-fMRI (first 100 timepoints) data, the default mode, motor, and language network maps were generated with atlas-based ROIs, Dice scores were calculated for the resting-state network maps from pseudo-rs-fMRI and truncated rs-fMRI using the full rs-fMRI maps as reference. Seed-to-voxel and ROI-to-ROI analyses were performed to assess FC differences between cognitively impaired and nonimpaired patients. RESULTS: Dice scores for the group-level and patient-level (mean±SD) default mode, motor, and language network maps using pseudo-rs-fMRI were 0.905/0.689 ± 0.118 (group/patient), 0.973/0.730 ± 0.124, and 0.935/0.665 ± 0.142, respectively. There was no significant difference in Dice scores between pseudo-rs-fMRI and the truncated rs-fMRI default mode (P = .97) or language networks (P = .30), but there was a difference in motor networks (P = .02). A multiple logistic regression classifier applied to ROI-to-ROI FC networks using pseudo-rs-fMRI could identify cognitively impaired patients (sensitivity = 84.6%, specificity = 63.6%, receiver operating characteristic area under the curve (AUC) = 0.7762 ± 0.0954 (standard error), P = .0221) and performance was not significantly different from full rs-fMRI predictions (AUC = 0.8881 ± 0.0733 (standard error), P = .0013, P = .29 compared with pseudo-rs-fMRI). CONCLUSIONS: DSC perfusion MRI-derived pseudo-rs-fMRI data can be used to perform typical rs-fMRI FC analyses that may identify cognitive decline in patients with brain tumors while still simultaneously performing perfusion analyses.

10.
AJNR Am J Neuroradiol ; 45(2): 188-197, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38238098

RESUMO

BACKGROUND AND PURPOSE: The T2-FLAIR mismatch sign on MR imaging is a highly specific imaging biomarker of isocitrate dehydrogenase (IDH)-mutant astrocytomas, which lack 1p/19q codeletion. However, most studies using the T2-FLAIR mismatch sign have used visual assessment. This study quantified the degree of T2-FLAIR mismatch using digital subtraction of fluid-nulled T2-weighted FLAIR images from non-fluid-nulled T2-weighted images in human nonenhancing diffuse gliomas and then used this information to assess improvements in diagnostic performance and investigate subregion characteristics within these lesions. MATERIALS AND METHODS: Two cohorts of treatment-naïve, nonenhancing gliomas with known IDH and 1p/19q status were studied (n = 71 from The Cancer Imaging Archive (TCIA) and n = 34 in the institutional cohort). 3D volumes of interest corresponding to the tumor were segmented, and digital subtraction maps of T2-weighted MR imaging minus T2-weighted FLAIR MR imaging were used to partition each volume of interest into a T2-FLAIR mismatched subregion (T2-FLAIR mismatch, corresponding to voxels with positive values on the subtraction maps) and nonmismatched subregion (T2-FLAIR nonmismatch corresponding to voxels with negative values on the subtraction maps). Tumor subregion volumes, percentage of T2-FLAIR mismatch volume, and T2-FLAIR nonmismatch subregion thickness were calculated, and 2 radiologists assessed the T2-FLAIR mismatch sign with and without the aid of T2-FLAIR subtraction maps. RESULTS: Thresholds of ≥42% T2-FLAIR mismatch volume classified IDH-mutant astrocytoma with a specificity/sensitivity of 100%/19.6% (TCIA) and 100%/31.6% (institutional); ≥25% T2-FLAIR mismatch volume showed 92.0%/32.6% and 100%/63.2% specificity/sensitivity, and ≥15% T2-FLAIR mismatch volume showed 88.0%/39.1% and 93.3%/79.0% specificity/sensitivity. In IDH-mutant astrocytomas with ≥15% T2-FLAIR mismatch volume, T2-FLAIR nonmismatch subregion thickness was negatively correlated with the percentage T2-FLAIR mismatch volume (P < .0001) across both cohorts. The percentage T2-FLAIR mismatch volume was higher in grades 3-4 compared with grade 2 IDH-mutant astrocytomas (P < .05), and ≥15% T2-FLAIR mismatch volume IDH-mutant astrocytomas were significantly larger than <15% T2-FLAIR mismatch volume IDH-mutant astrocytoma (P < .05) across both cohorts. When evaluated by 2 radiologists, the additional use of T2-FLAIR subtraction maps did not show a significant difference in interreader agreement, sensitivity, or specificity compared with a separate evaluation of T2-FLAIR and T2-weighted MR imaging alone. CONCLUSIONS: T2-FLAIR digital subtraction maps may be a useful, automated tool to obtain objective segmentations of tumor subregions based on quantitative thresholds for classifying IDH-mutant astrocytomas using the percentage T2 FLAIR mismatch volume with 100% specificity and exploring T2-FLAIR mismatch/T2-FLAIR nonmismatch subregion characteristics. Conversely, the addition of T2-FLAIR subtraction maps did not enhance the sensitivity or specificity of the visual T2-FLAIR mismatch sign assessment by experienced radiologists.


Assuntos
Astrocitoma , Neoplasias Encefálicas , Glioma , Humanos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/genética , Neoplasias Encefálicas/patologia , Estudos Retrospectivos , Glioma/diagnóstico por imagem , Glioma/patologia , Imageamento por Ressonância Magnética/métodos , Isocitrato Desidrogenase/genética , Mutação
11.
Neuro Oncol ; 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38808755

RESUMO

Typical longitudinal radiographic assessment of brain tumors relies on side-by-side qualitative visualization of serial magnetic resonance images (MRIs) aided by quantitative measurements of tumor size. However, when assessing slowly-growing tumors and/or complex tumors, side-by-side visualization and quantification may be difficult or unreliable. Whole-brain, patient-specific "digital flipbooks" of longitudinal scans are a potential method to augment radiographic side-by-side reads in clinical settings by enhancing the visual perception of changes in tumor size, mass effect, and infiltration across multiple slices over time. In this approach, co-registered, consecutive MRI scans are displayed in a slide deck, where one slide displays multiple brain slices of a single timepoint in an array (e.g. 3x5 "mosaic" view of slices). The flipbooks are viewed similar to an animated flipbook of cartoons/photos so that subtle radiographic changes are visualized via perceived motion when scrolling through the slides. Importantly, flipbooks can be created easily with free, open-source software. This article describes the step-by-step methodology for creating flipbooks and discusses clinical scenarios for which flipbooks are particularly useful. Example flipbooks are provided in the Online Supplemental Material.

12.
Neurooncol Adv ; 5(1): vdad084, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37554221

RESUMO

Background: Alterations in tumor growth rate (TGR) in recurrent glioblastoma (rGBM) after treatment may be useful for identifying therapeutic activity. The aim of this study was to assess the impact of volumetric TGR alterations on overall survival (OS) in rGBM treated with chemotherapy with or without radiation therapy (RT). Methods: Sixty-one rGBM patients treated with chemotherapy with or without concomitant radiation therapy (RT) at 1st or 2nd recurrence were retrospectively examined. Pre- and post-treatment contrast enhancing volumes were computed. Patients were considered "responders" if they reached progression-free survival at 6 months (PFS6) and showed a decrease in TGR after treatment and "non-responders" if they didn't reach PFS6 or if TGR increased. Results: Stratification by PFS6 and based on TGR resulted in significant differences in OS both for all patients and for patients without RT (P < 0.05). A decrease of TGR (P = 0.009), smaller baseline tumor volume (P = 0.02), O6-methylguanine-DNA methyltransferase promoter methylation (P = 0.048) and fewer number of recurrences (P = 0.048) were significantly associated with longer OS after controlling for age, sex and concomitant RT. Conclusion: A decrease in TGR in patients with PFS6, along with smaller baseline tumor volume, were associated with a significantly longer OS in rGBM treated with chemotherapy with or without radiation. Importantly, all patients that exhibited PFS6 also showed a measurable decrease in TGR.

13.
Jpn J Radiol ; 41(11): 1255-1264, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37219717

RESUMO

PURPOSE: This study aimed to investigate the uptake characteristics of 18F-fluoromisonidazole (FMISO), in mutant-type isocitrate dehydrogenase (IDH-mutant, grade 3 and 4) and wild-type IDH (IDH-wildtype, grade 4) 2021 WHO classification adult-type diffuse gliomas. MATERIALS AND METHODS: Patients with grade 3 and 4 adult-type diffuse gliomas (n = 35) were included in this prospective study. After registering 18F-FMISO PET and MR images, standardized uptake value (SUV) and apparent diffusion coefficient (ADC) were evaluated in hyperintense areas on fluid-attenuated inversion recovery (FLAIR) imaging (HIA), and in contrast-enhanced tumors (CET) by manually placing 3D volumes of interest. Relative SUVmax (rSUVmax) and SUVmean (rSUVmean), 10th percentile of ADC (ADC10pct), mean ADC (ADCmean) were measured in HIA and CET, respectively. RESULTS: rSUVmean in HIA and rSUVmean in CET were significantly higher in IDH-wildtype than in IDH-mutant (P = 0.0496 and 0.03, respectively). The combination of FMISO rSUVmean in HIA and ADC10pct in CET, that of rSUVmax and ADC10pct in CET, that of rSUVmean in HIA and ADCmean in CET, were able to differentiate IDH-mutant from IDH-wildtype (AUC 0.80). When confined to astrocytic tumors except for oligodendroglioma, rSUVmax, rSUVmean in HIA and rSUVmean in CET were higher for IDH-wildtype than for IDH-mutant, but not significantly (P = 0.23, 0.13 and 0.14, respectively). The combination of FMISO rSUVmean in HIA and ADC10pct in CET was able to differentiate IDH-mutant (AUC 0.81). CONCLUSION: PET using 18F-FMISO and ADC might provide a valuable tool for differentiating between IDH mutation status of 2021 WHO classification grade 3 and 4 adult-type diffuse gliomas.


Assuntos
Neoplasias Encefálicas , Glioma , Humanos , Adulto , Isocitrato Desidrogenase/genética , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/genética , Neoplasias Encefálicas/patologia , Estudos Prospectivos , Glioma/diagnóstico por imagem , Glioma/genética , Glioma/patologia , Mutação , Organização Mundial da Saúde , Tomografia por Emissão de Pósitrons , Estudos Retrospectivos
14.
Jpn J Radiol ; 41(11): 1216-1225, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37256470

RESUMO

PURPOSE: Neuromelanin-sensitive MRI (NM-MRI) has proven useful for diagnosing Parkinson's disease (PD) by showing reduced signals in the substantia nigra (SN) and locus coeruleus (LC), but requires a long scan time. The aim of this study was to assess the image quality and diagnostic performance of NM-MRI with a shortened scan time using a denoising approach with deep learning-based reconstruction (dDLR). MATERIALS AND METHODS: We enrolled 22 healthy volunteers, 22 non-PD patients and 22 patients with PD who underwent NM-MRI, and performed manual ROI-based analysis. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in ten healthy volunteers were compared among images with a number of excitations (NEX) of 1 (NEX1), NEX1 images with dDLR (NEX1 + dDLR) and 5-NEX images (NEX5). Acquisition times for NEX1 and NEX5 were 3 min 12 s and 15 min 58 s, respectively. Diagnostic performances using the contrast ratio (CR) of the SN (CR_SN) and LC (CR_LC) and those by visual assessment for differentiating PD from non-PD were also compared between NEX1 and NEX1 + dDLR. RESULTS: Image quality analyses revealed that SNRs and CNRs of the SN and LC in NEX1 + dDLR were significantly higher than in NEX1, and comparable to those in NEX5. In diagnostic performance analysis, areas under the receiver operating characteristic curve (AUC) using CR_SN and CR_LC of NEX1 + dDLR were 0.87 and 0.75, respectively, which had no significant difference with those of NEX1. Visual assessment showed improvement of diagnostic performance by applying dDLR. CONCLUSION: Image quality for NEX1 + dDLR was comparable to that of NEX5. dDLR has the potential to reduce scan time of NM-MRI without degrading image quality. Both 1-NEX NM-MRI with and without dDLR showed high AUCs for diagnosing PD by CR. The results of visual assessment suggest advantages of dDLR. Further tuning of dDLR would be expected to provide clinical merits in diagnosing PD.


Assuntos
Aprendizado Profundo , Doença de Parkinson , Humanos , Imageamento por Ressonância Magnética/métodos , Substância Negra , Melaninas , Doença de Parkinson/diagnóstico por imagem
15.
Clin Cancer Res ; 29(20): 4186-4195, 2023 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-37540556

RESUMO

PURPOSE: Antiangiogenic therapies are known to cause high radiographic response rates due to reduction in vascular permeability resulting in a lower degree of contrast extravasation. In this study, we investigate the prognostic ability for model-derived parameters describing enhancing tumor volumetric dynamics to predict survival in recurrent glioblastoma treated with antiangiogenic therapy. EXPERIMENTAL DESIGN: N = 276 patients in two phase II trials were used as training data, including bevacizumab ± irinotecan (NCT00345163) and cabozantinib (NCT00704288), and N = 74 patients in the bevacizumab arm of a phase III trial (NCT02511405) were used for validation. Enhancing volumes were estimated using T1 subtraction maps, and a biexponential model was used to estimate regrowth (g) and regression (d) rates, time to tumor regrowth (TTG), and the depth of response (DpR). Response characteristics were compared to diffusion MR phenotypes previously shown to predict survival. RESULTS: Optimized thresholds occurred at g = 0.07 months-1 (phase II: HR = 0.2579, P = 5 × 10-20; phase III: HR = 0.2197, P = 5 × 10-5); d = 0.11 months-1 (HR = 0.3365, P < 0.0001; HR = 0.3675, P = 0.0113); TTG = 3.8 months (HR = 0.2702, P = 6 × 10-17; HR = 0.2061, P = 2 × 10-5); and DpR = 11.3% (HR = 0.6326, P = 0.0028; HR = 0.4785, P = 0.0206). Multivariable Cox regression controlling for age and baseline tumor volume confirmed these factors as significant predictors of survival. Patients with a favorable pretreatment diffusion MRI phenotype had a significantly longer TTG and slower regrowth. CONCLUSIONS: Recurrent glioblastoma patients with a large, durable radiographic response to antiangiogenic agents have significantly longer survival. This information is useful for interpreting activity of antiangiogenic agents in recurrent glioblastoma.


Assuntos
Neoplasias Encefálicas , Glioblastoma , Humanos , Glioblastoma/diagnóstico por imagem , Glioblastoma/tratamento farmacológico , Bevacizumab/uso terapêutico , Inibidores da Angiogênese/uso terapêutico , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/tratamento farmacológico , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/tratamento farmacológico , Irinotecano/uso terapêutico , Imageamento por Ressonância Magnética/métodos
16.
Magn Reson Med Sci ; 21(4): 633-647, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34602534

RESUMO

PURPOSE: To compare reliability and elucidate clinical application of magnetization-prepared rapid gradient-echo (MPRAGE) with 9-fold acceleration by using wave-controlled aliasing in parallel imaging (Wave-CAIPI 3 × 3) in comparison to conventional MPRAGE accelerated by using generalized autocalibrating partially parallel acquisition (GRAPPA) 2 × 1. METHODS: A total of 26 healthy volunteers and 33 patients were included in this study. Subjects were scanned with two MPRAGEs, GRAPPA 2 × 1 and Wave-CAIPI 3 × 3 acquired in 5 min 21 s and 1 min 42 s, respectively, on a 3T MR scanner. Healthy volunteers underwent additional two MPRAGEs (CAIPI 3 × 3 and GRAPPA 3 × 3). The image quality of the four MPRAGEs was visually evaluated with a 5-point scale in healthy volunteers, and the SNR of four MPRAGEs was also calculated by measuring the phantom 10 times with each MPRAGE. Based on the results of the visual evaluation, voxel-based morphometry (VBM) analyses, including subfield analysis, were performed only for GRAPPA 2 × 1 and Wave-CAIPI 3 × 3. Correlation of segmentation results between GRAPPA 2 × 1 and Wave-CAIPI 3 × 3 was assessed. RESULTS: In visual evaluations, scores for MPRAGE GRAPPA 2 × 1 (mean rank: 4.00) were significantly better than those for Wave-CAIPI 3 × 3 (mean rank: 3.00), CAIPI 3 × 3 (mean rank: 1.83), and GRAPPA 3 × 3 (mean rank: 1.17), and scores for Wave-CAIPI 3×3 were significantly better than those for CAIPI 3 × 3 and GRAPPA 3 × 3. Image noise was evident at the center for additional MPRAGE CAIPI 3 × 3 and GRAPPA 3 × 3. The correlation of segmentation results between GRAPPA 2 × 1 and Wave-CAIPI 3 × 3 was higher than 0.85 in all VOIs except globus pallidus. Subfield analysis of hippocampus also showed a high correlation between GRAPPA 2 × 1 and Wave-CAIPI 3 × 3. CONCLUSION: MPRAGE Wave-CAIPI 3 × 3 shows relatively better contrast, despite of its short scan time of 1 min 42 s. The volumes derived from automated segmentation of MPRAGE Wave-CAIPI are considered to be reliable measures.


Assuntos
Artefatos , Aumento da Imagem , Algoritmos , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes
17.
Magn Reson Med Sci ; 21(4): 583-591, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34334585

RESUMO

PURPOSE: Diffusion-weighted MRI (DWI) is an essential sequence for evaluating pediatric patients with moyamoya disease (MMD); however, acoustic noise associated with DWI may lead to motion artifact. Compared with conventional DWI (cDWI), quiet DWI (qDWI) is considered less noisy and able to keep children more relaxed and stable. This study aimed to evaluate the suitability of qDWI compared with cDWI for pediatric patients with MMD. METHODS: In this observational study, MR examinations of the brain were performed either with or without sedation in pediatric patients with MMD between September 2017 and August 2018. Three neuroradiologists independently evaluated the images for artifacts and restricted diffusion in the brain. The differences between qDWI and cDWI were compared statistically using a chi-square test. RESULTS: One-hundred and six MR scans of 56 patients with MMD (38 scans of 15 sedated patients: 6 boys and 9 girls; mean age, 5.2 years; range, 1-9 years; and 68 scans of 42 unsedated patients: 19 boys and 23 girls; mean age, 10.7 years; range, 7-16 years) were evaluated. MR examinations were performed either with or without sedation (except in one patient). In sedated patients, no artifact other than susceptibility was observed on qDWI, whereas four artifacts were observed on cDWI (P = .04). One patient awoke from sedation during cDWI scanning, while no patient awoke from sedation during qDWI acquisition. For unsedated patients, three scans showed artifacts on qDWI, whereas two scans showed artifacts on cDWI (P = .65). Regarding restricted diffusion, qDWI revealed three cases, while two cases were found on cDWI (P = .66). CONCLUSION: qDWI induced fewer artifacts compared with cDWI in sedated patients, and similar frequencies of artifacts were induced by qDWI and by cDWI in unsedated patients. qDWI showed restricted diffusion comparable to cDWI.


Assuntos
Interpretação de Imagem Assistida por Computador , Doença de Moyamoya , Artefatos , Encéfalo/diagnóstico por imagem , Criança , Pré-Escolar , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Doença de Moyamoya/diagnóstico por imagem
18.
Invest Radiol ; 56(2): 69-77, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32649332

RESUMO

OBJECTIVES: The aim of this study was to assess the accuracy, reliability, and cerebral microbleed (CMB) detection performance of 2-minute quantitative susceptibility mapping (QSM) from 3-dimensional echo-planar imaging (3D-EPI). MATERIALS AND METHODS: Gadolinium phantom study was conducted using 3D-EPI, single-echo time (TE), and multi-TE gradient-recalled echo (GRE) sequences on two 3-T magnetic resonance (MR) scanners to assess the accuracy between measured and theoretical susceptibility values. The institutional review board approved this prospective study, and 40 healthy volunteers were enrolled with written consent between April 2018 and October 2019. Each underwent 3D-EPI, single-TE, and multi-TE GRE sequences consecutively on one 3-T MR scanner, and QSMs were calculated to assess the reliability of 3D-EPI QSM. Intraclass correlation coefficient (ICC), linear regression, and Bland-Altman plots were calculated. Patients with CMB who underwent both 3D-EPI and GRE QSM scans were retrospectively enrolled. Two radiologists evaluated images independently, and Cohen κ coefficients were calculated to compare CMB detection performance. RESULTS: Phantom study showed excellent validity of 3D-EPI QSM on both MR scanners: Skyra, R2 = 0.996, P < 0.001, ICC = 0.997, mean difference, -2 ppb (95% confidence interval [CI], -45 to 40 ppb); Prisma, R2 = 0.992, P < 0.001, ICC = 0.988, mean difference, 15 ppb (95% CI, -67 to 97 ppb). A human study of 40 healthy volunteers (59 ± 13 years, 25 women) showed excellent reliability with 3D-EPI QSM for both single-TE and multi-TE GRE (R2 = 0.981, P < 0.001, ICC = 0.988; R2 = 0.983, P < 0.001, ICC = 0.990, respectively), supported by a Bland-Altman mean difference of 4 ppb (95% CI, -15 to 23 ppb) for single-TE GRE and 3 ppb (95% CI, -15 to 20 ppb) for multi-TE GRE. The CMB detection performance evaluation from 38 patients (51 ± 20 years, 20 women) showed almost perfect agreement between 3D-EPI and GRE QSM for both raters (κ = 0.923 and 0.942, P < 0.001). CONCLUSIONS: Faster QSM from 3D-EPI demonstrated excellent accuracy, reliability, and CMB detection performance.


Assuntos
Imagem Ecoplanar , Imageamento por Ressonância Magnética , Hemorragia Cerebral/diagnóstico por imagem , Feminino , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA