Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 118
Filtrar
1.
Ann Surg ; 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38501239

RESUMO

OBJECTIVE: This study aimed to present the early and mid-term outcomes of fenestrated/branched thoracic endovascular aortic repair (f/bTEVAR) for aortic arch pathologies. BACKGROUND: f/bTEVAR represents a less invasive treatment option for aortic arch diseases. Previous published series showed decreased early mortality and morbidity compared to open repair. METHODS: A single-center retrospective analysis of consecutive patients, managed with f/bTEVAR (Cook Medical, Bloomington, IN, USA) between 01.09.11and 30.06.22 was conducted. Primary outcomes were technical success, 30-day mortality and stroke. Data during follow-up and factors affecting early mortality and stroke were analyzed. RESULTS: 209 patients were included (38.3% females; mean age 69.8±3.4years; mean aortic diameter 61±4.7 mm); 14.4% were managed urgently. Fenestrations/scallop configuration was used in 39.7%, branched devices in 55.5% and branch/scallop combination in 4.8%. Landing to zone 0 was performed in 65.5% and in zone 1 in 32.1%. Non-native aortas were used for landing in 39.2%. Technical success was 97.1% and 30-day mortality 9.5%. Strokes were identified in 10%; 5.7% major. Non-native proximal aortic landing zone was an independent protective factor for stroke (P=0.002). Post-operative stroke (P<0.001) and pericardial effusion (P<0.001) were independently related to 30-day mortality. The mean follow-up was 21±8 months. The estimated survival and freedom from reintervention rates were 79.5% (standard error; SE3.1%) and 47.1% (SE 4.3%) at 24months, respectively. CONCLUSIONS: f/bTEVAR presented high technical success and acceptable 30-day mortality. Non-native proximal landing zone was related to lower stroke rate. Half of patients needed a reintervention within the 24-month follow-up.

2.
Ann Surg ; 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38323417

RESUMO

OBJECTIVE: To analyze the outcomes of urgent/emergent endovascular aortic repair of patients with free/contained ruptured thoracoabdominal aortic aneurysms (rTAAA). BACKGROUND: Endovascular repair of rTAAA has been scarcely described in emergent setting. METHODS: An international multicenter retrospective observational study (ClinicalTrials.govID:NCT05956873) from January-2015 to January-2023 in 6 European and 1 United States Vascular Surgery Centers. Primary end-points were technical success, 30-day and/or in-hospital mortality and follow-up survival. RESULTS: A total of 100 rTAAA patients were included (75 male; mean age 73 y). All patients (86 contained and 14 free ruptures) were symptomatic and treated within 24-hours from diagnosis: multi-branched off-the-shelf devices (Zenith t-branch,Cook Medical Inc.Bjaeverskov,Denmark) in 88 patients, physician-modified endografts in 8, patient-specific device or parallel grafts in two patients each. Primary technical success was achieved in 89 patients and 30-day and/or in-hospital mortality was 24%. Major adverse events (MAEs) occurred in 34% of patients (permanent dialysis and paraplegia in 4 and 8 patients, respectively). No statistical differences were detected in mortality rates between free and contained ruptured patients (43%vs.21%; P =0.075). Multivariate analysis revealed contained rupture favoring technical success (Odd-Ratio10.1;95%Confidence-Interval:3.0-33.6; P =<0.001). MAEs (OR9.4;95%C-I:2.8-30.5; P =<0.001) and pulmonary complications (OR11.3;95%CI:3.0-41.5; P =<0.001) were independent risk factors for 30-day and/or in-hospital mortality. Median follow-up time was 13 months (interquartile range 5-24); 1-year survival rate was 65%. Aneurysm diameter>80 mm (Hazard-Ratio:2.0;95%CI:1.0-30.5; P =0.037), technical failure (HR:2.6;95%CI:1.1-6.5; P =0.045) and pulmonary complications (HR:3.0;95%CI:1.2-7.9; P =0.021) were independent risk factors for follow-up mortality. CONCLUSION: Endovascular repair of rTAAA shows high technical success; the presence of free rupture alone appear not to correlate with early mortality. Effective prevention/management of post-operative complications is crucial for survival.

3.
J Vasc Surg ; 79(3): 457-468.e2, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38453660

RESUMO

BACKGROUND: Fenestrated and branched endovascular aortic repair (F/BEVAR) of thoracoabdominal aortic aneurysms (TAAAs) has shown high technical success and low early mortality rates. Aneurysm extent has been reported as a factor affecting outcomes. This study aimed to assess the early and midterm follow-up outcomes of patients managed by F/BEVAR for types I through III TAAAs. METHODS: A single-center retrospective analysis was conducted, including data from consecutive, elective and urgent (symptomatic and ruptured cases), patients treated for types I through III TAAAs, between October 1, 2011, and October 1, 2022, using F/BEVAR. Degenerative and postdissection TAAAs were included. Patients received prophylactic cerebrospinal fluid drainage (CSFD), except those under therapeutic anticoagulation, those who were hemodynamically unstable, or those with failed CSFD application. When an initial thoracic endovascular aortic repair was performed, as part of a staged procedure, no CSFD was used. Later stages and nonstaged procedures were performed under CSFD. Thirty-day mortality and major adverse events (MAEs) were analyzed. Kaplan-Meier estimates were used for follow-up outcomes. RESULTS: F/BEVAR for types I through III TAAAs was performed in 209 patients (56.9% males; mean age, 69.6 ± 3.2 years; mean aneurysm diameter, 65.2 ± 6.2 mm); 29.2% type I, 57.9% type II, and 12.9% type III. Urgent repair was performed in 26.7% of patients (56 cases; 23 ruptured and 33 symptomatic cases) and 153 were treated electively. Thirty-two patients (15.3%) were classified as American Society of Anesthesiologists (ASA) class IV. CSFD was used in 91% and staged thoracic endovascular aortic repair was performed in 51.2% of patients. Technical success was 93.8% (96.7% in elective vs 94.6% in urgent cases; P = .92). Thirty-day mortality was 11.0% (4.6% in elective vs 28.5% in urgent cases; P < .001) and MAEs were recorded in 17.2% of cases (7.8% in elective vs 42.8% in urgent cases; P < .001). Spinal cord ischemia rate was 20.5% (17.6% in elective vs 28.7% in urgent cases; P = .08), whereas 2.9% of patients presented paraplegia (1.3% in elective and 7.1% in urgent cases; P = .03). The mean follow-up was 16 ± 5 months. Survival was 75.0% (standard error, 4.0%) and freedom from reintervention was 73.3% (standard error, 4.4%) at 36 months. ASA IV and urgent repair were detected as independent factors related to early mortality and MAE, whereas ruptured aneurysm status was related to spinal cord ischemia evolution. CONCLUSIONS: Endovascular repair for types I through III TAAAs provides encouraging early outcomes in terms of mortality, MAE, and paraplegia, especially in an elective setting. Setting of repair and baseline ASA score should be taken into consideration during decision-making.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Isquemia do Cordão Espinal , Masculino , Humanos , Idoso , Feminino , Correção Endovascular de Aneurisma , Prótese Vascular , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Isquemia do Cordão Espinal/etiologia , Paraplegia/etiologia
4.
J Vasc Surg ; 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38580160

RESUMO

OBJECTIVE: Fenestrated and branched thoracic endovascular repair (f/bTEVAR) have been successfully applied in patients with diverse aortic arch pathologies. The aim of this study is to present the early and mid-term outcomes of patients with native proximal aortic landing (NPAL) managed with f/bTEVAR. METHODS: A single-center retrospective analysis of patients with NPAL, managed with f/bTEVAR, between September 1, 2011, and June 30, 2022, was conducted. All patients were treated with custom-made devices (Cook Medical) with landing within Ishimaru zones 0 to 2. Primary outcomes were technical success, mortality, stroke, and retrograde type A dissection at 30 days. Follow-up outcomes were considered secondary. RESULTS: A total of 126 patients were included (69.8% males; mean age, 70.8 ± 4.2 years; 18.3% urgent). The main indications (60.4%) for repair were aortic arch (29.4%) and thoracoabdominal aortic aneurysms (31.0%). Seventy-two patients (57.1%) were managed with fTEVAR. Proximal landing in zone 0 and 1 was chosen in 97.6%. Technical success was 94.4%, and 30-day mortality was 11.9%. Strokes were diagnosed in 13.5% of patients and major strokes were identified in 7.9% cases. Retrograde type A dissection rate was 3.9%. The multivariate analysis confirmed landing in Ishimaru zone 0 as an independently related factor for stroke (P = .005), whereas stroke (P < .001), pericardial effusion (P < .001), and acute kidney injury (P < .001) were independently related to 30-day mortality. Mean follow-up was 17.5 ± 9.3 months. The estimated survival rate and the freedom from reintervention rate were 72.6% (standard error, 4.4%) and 46.4% (standard error, 6.0%) at 24-month follow-up, respectively. CONCLUSIONS: Stroke rate after endovascular arch repair was alarming among patients with NPAL. Proximal landing to zone 0 was related to higher risk of stroke. Reinterventions were common within the 24-month follow-up.

5.
Eur J Clin Invest ; 54(5): e14166, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38269600

RESUMO

BACKGROUND: Embolization of debris can complicate transcatheter aortic valve implantation (TAVI) causing stroke. Cerebral embolism protection (CEP) devices can divert or trap debris. PURPOSE: To evaluate the efficacy of CEP during TAVI vs the standard procedure. DATA SOURCES: PubMed, SCOPUS and DOAJ 1/01/2014-04/12/2023. STUDY SELECTION: Randomized and observational studies comparing CEP versus standard TAVI, according to PRISMA. PRIMARY OUTCOME: stroke. SECONDARY OUTCOMES: death, bleeding, vascular access complications, acute kidney injury and infarct area. DATA EXTRACTION: Two investigators independently assessed study quality and extracted data. DATA SYNTHESIS: Twenty-six articles were included (540.247 patients). The primary endpoint was significantly lower (RR = 0.800 95%CI:0.682-0.940; p = 0.007) with CEP. Similarly, death rates were significantly lower with CEP (RR = 0.610 95%CI:0.482-0.771; p < 0.001). No difference was found for bleeding (RR = 1.053 95%CI:0.793-1.398; p = 0.721), vascular complications (RR = 0.937 95%CI:0.820-1.070; p = 0.334) or AKI (RR = 0.982 95%CI:0.754-1.279; p = 0.891). CONCLUSIONS: Use of CEP during TAVI is associated with improved outcomes. Future studies will identify patients who benefit most from CEP.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estudos Observacionais como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
6.
J Endovasc Ther ; : 15266028241231905, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38380515

RESUMO

INTRODUCTION: Data on target vessel (TV)-related outcomes in patients managed with branched thoracic endovascular aortic repair (BTEVAR) are limited. This study aimed to present the TV-related outcomes of BTEVAR in patients managed for aortic arch pathologies at 30 days and during follow-up. METHODS: A retrospective analysis of consecutive patients, managed between September 1, 2011, and June 30, 2022, with custom-made aortic arch endografts (Cook Medical, Bloomington, IN, USA), presenting at least one branch configuration, were eligible. Primary outcomes were technical success, TV-related patency, and reinterventions at 30 days. RESULTS: In total, 255 TVs were revascularized using branches: 107 innominate arteries (IAs), 108 left common carotid arteries (LCCAs), and 40 left subclavian arteries (LSAs). Covered stents were used as bridging stents of which 10.2% were balloon expandable. Relining, using bare-metal stents (BMS), was performed in 14.0% of IAs, 35.2% of LCCAs, and 22.5% of LSAs. Technical success on case basis was 99.2%; no failure was related to unsuccessful TV bridging. At 30 day follow-up, no TV occlusion was detected. In 5.6% of cases, a type Ic or III endoleak, attributed to TVs, was recorded. Two patients needed early branch-related reintervention. The mean follow-up was 18.3±9.2 months. Freedom from TV instability was 94.6% (standard error [SE] 2.5%] at 12 months. No TV stenosis or occlusion was detected up to 48 months of follow-up. Freedom from TV-related reinterventions was 95.4% [SE 2.4%] at 12 months. CONCLUSION: TV stenosis or occlusion in BTEVAR cases is rare and TV-related reinterventions and instability events are mainly attributed to type Ic and III endoleak formation. CLINICAL IMPACT: Previous studies focusing on target vessel (TV) outcomes after endovascular aortic arch repair are limited. In this study, including 255 TVs revascularized using branched arch devices, bridging was performed with covered stents, of which 90% were self-expanding. Relining was at the discretion of the operator and was 14% for the innominate, 35.2% for the left common carotid and 22.5% for the left subclavian artery branches. No 30-day occlusion was detected. The freedom from TV instability was almost 95% at 12 months. TV instability and reintervention were mainly attributed to endoleaks type Ic and IIIc.

7.
J Endovasc Ther ; : 15266028241245341, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38597263

RESUMO

OBJECTIVES: Electrosurgery has been long used in endovascular procedures, with only case reports in the aortic field. Our aim is to present a case series with the use of an electrified wire to perform catheter-based electrosurgery by applying external current through an electrocautery pen. METHODS: Single-center retrospective case series of all patients undergoing complex aortic surgery from October 2020 to August 2023, in whom the electrified wire technique was used: (1) Perforation of a dissection flap or left subclavian artery (LSA) in situ endograft fenestration-a 0.014" polytetrafluoroethylene (PTFE) insulated guidewire is detached from the insulation with a scalpel at the end and a cautery pen is here attached with a clamp. A curved tip catheter or sheath is positioned against the aortic flap or the endograft (through a left brachial access in this case) and the wire pushed, crossing the flap by activating the electrocautery pen and (2) slicing a dissection flap ("powered cheese-wire technique")-after same preparation as above, the middle section of the 0.014 guidewire is removed from the PTFE and bent into a V-shape. Once in the aorta, the guidewire crosses from the true lumen (TL) to the false lumen (FL) and a through-and-through access is obtained. Sheaths are positioned against the flap from both sides and moved up or down while the electricity is activated, slicing the flap and communicating both lumens. Technical success and technical-related complications were evaluated. RESULTS: Eleven cases concerning aortic dissections and 1 case of aortic atresia were treated. Four patients presented urgently, whereas the rest were planned procedures. Seven cases underwent perforation of a dissection flap, 2 cases underwent the powered cheese-wire technique, in 2 cases for an LSA in situ fenestration, and in 1 case to cross an aortic atresia at the aortic isthmus. The technique was in all cases successfully applied. No complications related to the technique occurred. CONCLUSIONS: The "electrified wire" technique is a feasible and ready-available tool that can be safely used in complex aortic interventions, especially to perforate aortic tissue like dissection flaps or to perform in situ fenestrated repairs by perforation of the endograft fabric. CLINICAL IMPACT: The electrified wire technique described herein is a straightforward technique that uses readily available tools to perform electrosurgery. We present its use in complex aortic procedures. However, it could be envisioned for any vascular procedure that requires crossing of the vessel or even prosthetic material. As we have described in this series, when used along with an adequate properative planning, it can be a safe tool of great utility, as has already been demonstarted in the field of the interventional cardiology.

8.
J Endovasc Ther ; : 15266028241251985, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38708984

RESUMO

PURPOSE: The treatment of thoracoabdominal aortic aneurysms (TAAAs) using branched endovascular aortic repair (BEVAR) is safe and effective. During deployment, the superior mesenteric artery (SMA) branch can unintentionally open into the celiac trunk (CT) ostium and switched catheterization of the SMA from the CT branch and the CT from the SMA branch can be used as an alternative technique in these cases. This study aimed to investigate the outcome of exchanging the intended target vessels (TVs) for the CT and SMA branches during BEVAR. MATERIALS AND METHODS: A single-center retrospective analysis of patients with TAAAs who underwent BEVAR, using off-the-shelf or custom-made devices (CMDs), with an unintended exchange of TVs for the CT and SMA branches was performed. RESULTS: Between 2014 and 2023, 397 patients were treated with BEVAR for TAAA. Eighteen (4.5%) of those patients were treated with an exchange of TVs for the CT and SMA branches. T-branch was used in 9 cases (50%) and the remaining patients were treated with CMDs. Twelve patients were treated electively, 3 were symptomatic and 3 presented with rupture. Of 36 mesenteric TVs in those 18 patients, 34 (94%) were catheterized successfully, including all 18 SMAs and 16 of the 18 CTs. No branch stenosis or occlusion of the switched mesenteric TVs was detected during follow-up. During 30-day follow-up, 3 patients died and during a median follow-up of 3 (interquartile range [IQR]: 1-15) months 3 more patients died. None of the deaths or the 2 unintended reinterventions was induced by the mesenteric TV exchange. The median hospital stay was 14 (IQR: 9-22) days with a median of 4 (IQR: 2-11) days at the intensive care unit. CONCLUSION: The exchange of the mesenteric TVs for the CT and SMA branches during BEVAR with off-the-shelf and CMD endografts is feasible with good TV patency and freedom from TV-related reinterventions. This alternative technique should be considered in selected cases when direct catheterization via the intended branch is deemed more time-consuming or not feasible. CLINICAL IMPACT: This is the first description of using an exchange of target vessels for the celiac trunk and the superior mesenteric artery branches in patients with thoracoabdominal aortic aneurysms undergoing BEVAR, using off-the-shelf or custom-made devices. The high success rate as well as the good clinical results without any branch stenosis or occlusion during follow-up highlight the feasibility of this alternative technique. It could help in challenging cases when catheterization of the intended target vessels is not possible or too time consuming, resulting in higher success rates of BEVAR and better clinical results.

9.
Artigo em Inglês | MEDLINE | ID: mdl-38697255

RESUMO

OBJECTIVE: Fenestrated or branched endovascular aortic repair (F/B-EVAR) is a valuable treatment in patients with chronic post-dissection thoraco-abdominal aneurysm (PD-TAAA). This study aimed to analyse early and follow up outcomes of F/B-EVAR in these patients. METHODS: Thirty day and follow up outcomes of consecutive patients with PD-TAAA treated with F/B-EVAR in a tertiary centre over eight years were analysed retrospectively. All patients presenting with PD-TAAA and managed with F/B-EVAR were eligible. A modified Crawford's classification system was used. Thirty day mortality and major adverse event (MAE) rates were analysed. Time to event data were estimated with Kaplan-Meier survival analysis. RESULTS: Fifty five patients (80% men, mean age 63.7 ± 7.7 years) were included: 12 (22%) were managed urgently; 25 (46%) for chronic type B aortic dissection; and the remainder for residual type A aortic dissection. Of these patients, 88% had undergone previous thoracic endovascular aortic repair. Prophylactic cerebrospinal fluid drainage (CSFD) was used in 91%. Fifteen (27%) patients were treated with F-EVAR, nine (16%) with fenestrations and branches, and 31 (56%) with B-EVAR. False lumen adjunctive procedures were used in 56%. Technical success was achieved in 96% of patients. The thirty day mortality rate was 7% and MAE rate was 20%. Spinal cord injury (SCI) grades 1 - 3 and grade 3 rates were 13% and 2%, respectively. Mean follow up was 33.0 ± 18.4 months. Survival and freedom from unscheduled re-intervention were 86% (standard error [SE] 5%) and 55% (SE 8%) at 24 months, respectively. Freedom from target vessel stenosis and occlusion was higher in F-EVAR at the 12 month follow up (p = .006) compared with B-EVAR. CONCLUSION: Fenestrated or branched endovascular repairs in patients with PD-TAAA showed high technical success, with acceptable early mortality and MAE rates. The SCI rate was > 10%, despite CSFD use and staged procedures. Almost a half of patients needed an unscheduled re-intervention within 24 months after F/B-EVAR.

10.
Eur J Vasc Endovasc Surg ; 67(6): 895-902, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38320646

RESUMO

OBJECTIVE: Iliac branch devices (IBDs) have shown good results but there is little evidence for the risk of internal iliac artery (IIA) endoleak, so there are no clear recommendations on the maximum diameter it should be. Based on limited evidence, it was hypothesised that an IIA of ≥ 11 mm in diameter presents an increased risk of type Ic endoleak. METHODS: This was a single centre, retrospective case control study. Patients undergoing an IBD with the main trunk of the IIA as the target vessel, between 2015 and 2021, were identified. Two groups were created: those with a main trunk diameter of < 11 mm; and those with a diameter of ≥ 11 mm. Technical success, freedom from type Ic endoleak, and re-intervention rates were compared. A receiver operating characteristic (ROC) curve was performed to show a cutoff IIA diameter value for risk of type Ic endoleak. Multivariate analysis was performed to assess the risk of type Ic endoleak and the presence of calcification, stenosis, and landing zone length in the IIA. RESULTS: There were 182 IBDs identified. The dilated IIA group (54 IBDs) had significantly lower technical success (91% vs. 98.4%; p = .002), lower freedom from type Ic endoleak (77% vs. 97.1% at 24 months; p = .001), and lower freedom from re-interventions (70% vs. 92.4% at 24 months; p = .002). The ROC curve showed that 10.5 mm was the cutoff diameter for type Ic endoleak. Moderate or severe calcification as well as landing zone length < 5 mm also correlated with type Ic endoleak. CONCLUSION: IBDs have a statistically significantly higher rate of technical failure, lower freedom from type Ic endoleak, and lower freedom from re-intervention when the IIA is ≥ 11 mm in diameter.


Assuntos
Implante de Prótese Vascular , Endoleak , Procedimentos Endovasculares , Artéria Ilíaca , Humanos , Endoleak/etiologia , Estudos Retrospectivos , Masculino , Feminino , Idoso , Artéria Ilíaca/cirurgia , Artéria Ilíaca/diagnóstico por imagem , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Fatores de Risco , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Idoso de 80 Anos ou mais , Prótese Vascular , Medição de Risco , Resultado do Tratamento , Estudos de Casos e Controles , Dilatação Patológica , Desenho de Prótese , Pessoa de Meia-Idade , Stents/efeitos adversos
11.
Artigo em Inglês | MEDLINE | ID: mdl-38677467

RESUMO

OBJECTIVE: Female sex is a risk factor for adverse events after endovascular aortic repair. Sex comparative early and midterm outcomes of fenestrated and branched endovascular aortic arch repair (F/B-Arch) are presented. METHODS: A single centre retrospective sex comparative analysis of consecutive patients managed with F/B-Arch was conducted according to STROBE. Primary outcomes were sex comparative technical success, death, and cerebrovascular morbidity at 30 days. Kaplan-Meier estimates were used for follow up outcomes. RESULTS: Among 209 patients, 38.3% were women. Coronary artery disease (p < .001) and previous myocardial infarction (p = .001) were more common in women. Non-native proximal aortic landing was higher in women (women: 51.3%; men: 31.8%, p = .005) and the aortic dissection rate was lower (28.8% vs. 48.1%, p = .005). Proximal landing to Ishimaru zones showed no difference (zone 0: p = .18; zone 1: p = .47; zone 2: p = .39). Graft configurations were equally distributed. In total, 416 supra-aortic trunks were bridged. The median number of revascularisations per patient was two (interquartile range 1, 3), with no difference between sexes (p = .54). Technical success (women: 97.5%; men: 96.9%, p = .80), 30 day mortality rate (women: 10%; men: 9.3%, p = .86), and cerebrovascular morbidity (women: 11.3%; men: 17.1%, p = .25) were similar. Women presented more access related complications (women: 32.5%; men: 16.3%, p = .006), without affecting access related re-interventions (p = .55). Survival (women: 81.1%, 95% confidence interval [CI] 76.3 - 85.9%; men: 79.8%, 95% CI 76.0 - 83.6%) and freedom from re-intervention (women: 56.6%, 95% CI 50.4 - 62.8%; men: 55.3%, 95% CI 50.1 - 60.5%) at 12 months were similar (log rank, p = .40 and p = .41, respectively). CONCLUSION: Both sexes presented similar outcomes after F/B-Arch. Appropriate patient selection may decrease the effect of sex in F/B-Arch outcomes.

12.
Artigo em Inglês | MEDLINE | ID: mdl-38705454

RESUMO

OBJECTIVE: This study aimed to report the initial experience with a novel bidirectional double cuff inner branch design for incorporation of renal and mesenteric arteries in patients undergoing fenestrated and branched endovascular aortic repair (F/BEVAR). METHODS: A retrospective review was undertaken of the experience of F/BEVAR with grafts integrating at least one bidirectional double cuffed inner branch implanted at three tertiary aortic centres between March 2022 and June 2023. All consecutive patients were included. Baseline characteristics, operative data, and follow up data were collected. Results were presented as number or median (interquartile range) unless otherwise stated. RESULTS: Thirteen patients (10 male; median age 72 [68, 77] years) had F/BEVAR using a total of 15 bidirectional double cuffed inner branches (30 cuffs). Indications for bidirectional doubled cuffed inner branches included cranial vessel orientation or double renal arteries in four patients each, common coeliomesenteric trunk in three patients, and early renal artery bifurcation, renal artery origin from a false lumen requiring a flexible route for catheterisation, and surplus configuration in one patient each. Twenty three of the 30 cuffs were used, whereas the remaining seven cuffs were intentionally occluded with vascular plugs. Target vessel incorporation was successful in all bidirectional branches. There was one technical failure related to unsuccessful catheterisation of a left renal artery targeted through a unidirectional caudal inner branch. During a median follow up of seven months there were no instances of target vessel instability or re-interventions and two patients died of causes unrelated to the bidirectional branches. CONCLUSION: The results of the use of bidirectional double cuff inner branches are promising, with high technical success and no short term branch related complications in this preliminary experience. This could potentially expand the applicability of branch endografting of complex endovascular aortic repairs, but long term results are still missing.

13.
Ann Surg ; 278(2): e389-e395, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35837956

RESUMO

OBJECTIVE: To report the mid-term outcomes of fenestrated-branched endovascular aneurysm repair (F-BEVAR) following a failed previous endovascular aneurysm repair (pEVAR) or previous open aneurysm repair (pOAR). METHODS: Data from consecutive patients who underwent F-BEVAR for pEVAR or pOAR from 2006 to 2021 from 17 European vascular centers were analyzed. Endpoints included technical success, major adverse events, 30-day mortality, and 5-year estimates of survival, target vessel primary patency, freedom from reinterventions, type I/III endoleaks, and sac growth >5 mm. BACKGROUND: Treatment of a failed previous abdominal aortic aneurysm repair is a complex undertaking. F-BEVAR is becoming an increasingly attractive option, although comparative data are limited regarding associated risk factors, indications for treatment, and various outcomes. RESULTS: There were 526 patients included, 268 pOAR and 258 pEVAR. The median time from previous repair to F-BEVAR was 7 (interquartile range, 4-12) years, 5 (3-8) for pEVAR, and 10 (6-14) for pOAR, P <0.001. Predominant indication for treatment was type Ia endoleak for pEVAR and progression of the disease for pOAR. Technical success was 92.8%, pOAR (92.2%), and pEVAR (93.4%), P =0.58. The 30-day mortality was 6.5% overall, 6.7% for pOAR, and 6.2% for pEVAR, P =0.81. There were 1853 treated target vessels with 5-year estimates of primary patency of 94.4%, pEVAR (95.2%), and pOAR (94.4%), P =0.03. Five-year estimates for freedom from type I/III endoleaks were similar between groups; freedom from reintervention was lower for pEVAR (38.3%) than for pOAR (56.0%), P =0.004. The most common indication for reinterventions was for type I/III endoleaks (37.5%). CONCLUSIONS: Repair of a failed pEVAR or pOARis safe and feasible with comparable technical success and survival rates. While successful treatment can be achieved, significant rates of reintervention should be anticipated, particularly for issues related to instability of target vessels/bridging stents.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Correção Endovascular de Aneurisma , Endoleak/epidemiologia , Endoleak/cirurgia , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Fatores de Tempo , Fatores de Risco , Sistema de Registros , Estudos Retrospectivos , Desenho de Prótese
14.
Ann Surg ; 278(4): 568-577, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37395613

RESUMO

OBJECTIVE: To describe outcomes after elective and non-elective fenestrated-branched endovascular aortic repair (FB-EVAR) for thoracoabdominal aortic aneurysms (TAAAs). BACKGROUND: FB-EVAR has been increasingly utilized to treat TAAAs; however, outcomes after non-elective versus elective repair are not well described. METHODS: Clinical data of consecutive patients undergoing FB-EVAR for TAAAs at 24 centers (2006-2021) were reviewed. Endpoints including early mortality and major adverse events (MAEs), all-cause mortality, and aortic-related mortality (ARM), were analyzed and compared in patients who had non-elective versus elective repair. RESULTS: A total of 2603 patients (69% males; mean age 72±10 year old) underwent FB-EVAR for TAAAs. Elective repair was performed in 2187 patients (84%) and non-elective repair in 416 patients [16%; 268 (64%) symptomatic, 148 (36%) ruptured]. Non-elective FB-EVAR was associated with higher early mortality (17% vs 5%, P <0.001) and rates of MAEs (34% vs 20%, P <0.001). Median follow-up was 15 months (interquartile range, 7-37 months). Survival and cumulative incidence of ARM at 3 years were both lower for non-elective versus elective patients (50±4% vs 70±1% and 21±3% vs 7±1%, P <0.001). On multivariable analysis, non-elective repair was associated with increased risk of all-cause mortality (hazard ratio, 1.92; 95% CI] 1.50-2.44; P <0.001) and ARM (hazard ratio, 2.43; 95% CI, 1.63-3.62; P <0.001). CONCLUSIONS: Non-elective FB-EVAR of symptomatic or ruptured TAAAs is feasible, but carries higher incidence of early MAEs and increased all-cause mortality and ARM than elective repair. Long-term follow-up is warranted to justify the treatment.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Correção Endovascular de Aneurisma , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Fatores de Tempo , Estudos Retrospectivos , Prótese Vascular
15.
J Vasc Surg ; 77(1): 3-8.e2, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35963458

RESUMO

OBJECTIVE: Fiber Optic RealShape (FORS) technology has recently been introduced as an adjunctive guidance technology that allows real-time three-dimensional visualization of dedicated endovascular devices while avoiding radiation exposure. It consists of equipment which sends pulses of light through hair-thin optical fibers that run within a dedicated hydrophilic wire and selective catheters. The purpose of the study was to report the observed benefits and limitations related to the first edition of FORS technology. METHODS: Data were collected prospectively from the first 50 patients undergoing FORS-guided endovascular repair at a single center between February 2020 and February 2021 as part of the global multicenter FORS Learn registry. All consecutive, elective procedures with one or more navigation tasks attempted with FORS were included. Factors related to FORS navigation task success were assessed. The time required for the catheterization of each task as well as the amount of radiation exposure (fluoroscopy time, dose area product, and estimated skin dose) were collected. A per-task analysis was conducted. End points included the success rate in achieving a stable FORS-guided catheterization, catheterization time, and radiation dose during catheterization. RESULTS: During the study period from February 2020 to February 2021, 50 patients were treated using FORS technology. Forty-five patients were treated for aortic aneurysm, 4 for iliac artery aneurysm, and 1 for splenic artery aneurysm. Overall, 201 navigation tasks were completed for these procedures and FORS was used in 186 tasks (92.5%). No FORS-related complication was recorded and a success rate of 60.2% (n = 116) was observed. Target vessel (TV) angle of 45° or greater, TV stenosis, and the renal arteries as navigation tasks (compared with celiac artery or superior mesenteric artery) were associated with a lower success rate. Catheterization of a TV through a branch more frequently required a standard catheter in combination with the FORS-enabled guidewire. Successful task catheterization using FORS guidance was associated with a shorter catheterization time 6 minutes (interquartile range, 3-11 minutes) versus 16 minutes (interquartile range, 10-24 minutes) (P < .001) and lower radiation exposure compared with unsuccessful catheterization (dose area product, 4.4 cGy/cm2 vs 12.5 cGy/cm2; P < .001). CONCLUSIONS: FORS technology was implemented successfully as a new guidance technology in a complex endovascular aortic repair program and was associated with an encouraging success rate and a high potential for radiation reduction.


Assuntos
Aneurisma Aórtico , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aneurisma Aórtico/cirurgia , Cateterismo , Catéteres , Tecnologia , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento
16.
J Vasc Surg ; 78(4): 863-873.e3, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37330705

RESUMO

OBJECTIVE: Analyze the outcomes of endovascular complex abdominal and thoracoabdominal aortic aneurysm repair using the Cook fenestrated device with the modified preloaded delivery system (MPDS) with a biport handle and preloaded catheters. METHODS: A multicenter retrospective single arm cohort study was performed, including all consecutive patients with complex abdominal aortic aneurysm repair and thoracoabdominal aortic aneurysms treated with the MPDS fenestrated device (Cook Medical). Patient clinical characteristics, anatomy, and indications for device use were collected. Outcomes, classified according to the Society for Vascular Surgery reporting standards, were collected at discharge, 30 days, 6 months, and annually thereafter. RESULTS: Overall, 712 patients (median age, 73 years; interquartile range [IQR], 68-78 years; 83% male) from 16 centers in Europe and the United States treated electively were included: 35.4% (n = 252) presented with thoracoabdominal aortic aneurysms and 64.6% (n = 460) with complex abdominal aortic aneurysm repair. Overall, 2755 target vessels were included (mean ,3.9 per patient). Of these, 1628 were incorporated via ipsilateral preloads using the MPDS (1440 accessed from the biport handle and 188 from above). The mean size of the contralateral femoral sheath during target vessel catheterization was 15F ± 4, and in 41 patients (6.7%) the sheath size was ≤8F. Technical success was 96.1%. Median procedural time was 209 minutes (IQR, 161-270 minutes), contrast volume was 100 mL (IQR, 70-150mL), fluoroscopy time was 63.9 minutes (IQR, 49.7-80.4 minutes) and median cumulative air kerma radiation dose was 2630 mGy (IQR, 838-5251 mGy). Thirty-day mortality was 4.8% (n = 34). Access complications occurred in 6.8% (n = 48) and 30-day reintervention in 7% (n = 50; 18 branch related). Follow-up of >30 days was available for 628 patients (88%), with a median follow-up of 19 months (IQR, 8-39 months). Branch-related endoleaks (type Ic/IIIc) were observed in 15 patients (2.6%) and aneurysm growth of >5 mm was observed in 54 (9.5%). Freedom from reintervention at 12 and 24 months was 87.1% (standard error [SE],1.5%) and 79.2% (SE, 2.0%), respectively. Overall target vessel patency at 12 and 24 months was 98.6% (SE, 0.3%) and 96.8% (SE, 0.4%), respectively, and was 97.9% (SE, 0.4%) and 95.3% (SE, 0.8%) for arteries stented from below using the MPDS, respectively. CONCLUSIONS: The MPDS is safe and effective. Overall benefits include a decrease in contralateral sheath size in the treatment of complex anatomies with favorable results.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Idoso , Feminino , Prótese Vascular , Correção Endovascular de Aneurisma , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Estudos Retrospectivos , Estudos de Coortes , Resultado do Tratamento , Fatores de Tempo , Desenho de Prótese
17.
J Vasc Surg ; 78(4): 854-862.e1, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37321524

RESUMO

OBJECTIVE: This multicenter international study aimed to describe outcomes of fenestrated-branched endovascular aortic repairs (FB-EVAR) in a cohort of patients treated for chronic post-dissection thoracoabdominal aortic aneurysms (PD-TAAAs). METHODS: We reviewed the clinical data of all consecutive patients treated by FB-EVAR for repair of extent I to III PD-TAAAs in 16 centers from the United States and Europe (2008-2021). Data were extracted from institutional prospectively maintained databases and electronic patient records. All patients received off-the-shelf or patient-specific manufactured fenestrated-branched stent grafts. Endpoints were any cause mortality and major adverse events at 30 days, technical success, target artery (TA) patency, freedom from TA instability, minor (endovascular with <12 Fr sheath) and major (open or ≥12 Fr sheath) secondary interventions, patient survival, and freedom from aortic-related mortality (ARM). RESULTS: A total of 246 patients (76% male; median age, 67 years [interquartile range, 61-73 years]) were treated for extent I (7%), extent II (55%), and extent III (35%) PD-TAAAs by FB-EVAR. The median aneurysm diameter was 65 mm (interquartile range, 59-73 mm). Eighteen patients (7%) were octogenarians, 212 (86%) were American Society of Anesthesiologists class ≥3, and 21 (9%) presented with contained ruptured or symptomatic aneurysms. There were 917 renal-mesenteric vessels targeted by 581 fenestrations (63%) and 336 directional branches (37%), with a mean of 3.7 vessels per patient. Technical success was 96%. Mortality and rate of major adverse events at 30 days was 3% and 28%, including disabling complications such as new onset dialysis in 1%, major stroke in 1%, and permanent paraplegia in 2%. Mean follow-up was 24 months. Kaplan-Meier (KM) estimated patient survival at 3 and 5 years was 79% ± 6% and 65% ± 10%. KM estimated freedom from ARM was 95% ± 3% and 93% ± 5% at the same intervals. Unplanned secondary interventions were needed in 94 patients (38%), including minor procedures in 64 (25%) and major procedures in 30 (12%). There was one conversion to open surgical repair (<1%). KM estimated freedom from any secondary intervention was 44% ± 9% at 5 years. KM estimated primary and secondary TA patency were 93% ± 2% and 96% ± 1% at 5 years, respectively. CONCLUSIONS: FB-EVAR for chronic PD-TAAAs was associated with high technical success and a low rate of mortality (3%) and disabling complications at 30 days. Although the procedure is effective in the prevention of ARM, patient survival was low at 5 years (65%), likely due to the significant comorbidities in this cohort of patients. Freedom from secondary interventions at 5 years was 44%, although most procedures were minor. The significant rate of reinterventions highlights the need for continued patient surveillance.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Correção Endovascular de Aneurisma , Procedimentos Endovasculares/efeitos adversos , Complicações Pós-Operatórias , Estudos Retrospectivos , Fatores de Risco , Stents/efeitos adversos , Resultado do Tratamento
18.
J Vasc Surg ; 77(6): 1588-1597.e4, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36731757

RESUMO

OBJECTIVE: The aim of this study was to compare outcomes of single or multistage approach during fenestrated-branched endovascular aortic repair (FB-EVAR) of extensive thoracoabdominal aortic aneurysms (TAAAs). METHODS: We reviewed the clinical data of consecutive patients treated by FB-EVAR for extent I to III TAAAs in 24 centers (2006-2021). All patients received a single brand manufactured patient-specific or off-the-shelf fenestrated-branched stent grafts. Staging strategies included proximal thoracic aortic repair, minimally invasive segmental artery coil embolization, temporary aneurysm sac perfusion and combinations of these techniques. Endpoints were analyzed for elective repair in patients who had a single- or multistage approach before and after propensity score adjustment for baseline differences, including the composite 30-day/in-hospital mortality and/or permanent paraplegia, major adverse event, patient survival, and freedom from aortic-related mortality. RESULTS: A total of 1947 patients (65% male; mean age, 71 ± 8 years) underwent FB-EVAR of 155 extent I (10%), 729 extent II (46%), and 713 extent III TAAAs (44%). A single-stage approach was used in 939 patients (48%) and a multistage approach in 1008 patients (52%). A multistage approach was more frequently used in patients undergoing elective compared with non-elective repair (55% vs 35%; P < .001). Staging strategies were proximal thoracic aortic repair in 743 patients (74%), temporary aneurysm sac perfusion in 128 (13%), minimally invasive segmental artery coil embolization in 10 (1%), and combinations in 127 (12%). Among patients undergoing elective repair (n = 1597), the composite endpoint of 30-day/in-hospital mortality and/or permanent paraplegia rate occurred in 14% of single-stage and 6% of multistage approach patients (P < .001). After adjustment with a propensity score, multistage approach was associated with lower rates of 30-day/in-hospital mortality and/or permanent paraplegia (odds ratio, 0.466; 95% confidence interval, 0.271-0.801; P = .006) and higher patient survival at 1 year (86.9±1.3% vs 79.6±1.7%) and 3 years (72.7±2.1% vs 64.2±2.3%; adjusted hazard ratio, 0.714; 95% confidence interval, 0.528-0.966; P = .029), compared with a single stage approach. CONCLUSIONS: Staging elective FB-EVAR of extent I to III TAAAs was associated with decreased risk of mortality and/or permanent paraplegia at 30 days or within hospital stay, and with higher patient survival at 1 and 3 years.


Assuntos
Aneurisma , Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Implante de Prótese Vascular/efeitos adversos , Correção Endovascular de Aneurisma , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Prótese Vascular , Aneurisma/cirurgia , Estudos Retrospectivos , Desenho de Prótese
19.
J Endovasc Ther ; 30(1): 29-33, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35018862

RESUMO

PURPOSE: The purpose of this study was to describe the use of a wire and catheters embedded with optical fiber (Fiber Optic RealShape [FORS]) to catheterize tortuous target vessels avoiding radiation. TECHNIQUE: A virtual biplane vies was simulated coupling traditional x-ray system, preoperative CT scan, and FORS system to treat an isolated hypogastric aneurysm. Despite the complex anatomy, catheterization of all target vessels was possible in 12 minutes with 19 seconds of fluoroscopy time (Radiation Exposure 3.8 mGy×cm2). A minimal invasive endovascular exclusion of the aneurysm was achieved through selective coil-embolization of the iliolumbar artery and implantation of balloon expandable covered stents, thus preserving the perfusion of the superior gluteal artery. CONCLUSION: FORS guidance allowed catheterization of a target vessel with challenging anatomy with a low radiation exposure.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Cateterismo , Prótese Vascular , Stents , Tecnologia
20.
J Endovasc Ther ; 30(4): 609-614, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35502737

RESUMO

PURPOSE: To describe the technical aspects and early results of a new endovascular fenestration method for false lumen occlusion in chronic aortic dissection: the Knickerbocker Technique. METHODS: A retrospective observational study including all consecutively treated patients between November 1, 2012, through May 31, 2016, who underwent thoracic endovascular aortic repair with false lumen occlusion using the Knickerbocker Technique for thoracic false lumen aneurysm in chronic aortic dissection in a tertiary care center. Primary endpoints consisted of technical (correct deployment of the stent-graft) and clinical (false lumen occlusion) success. Secondary endpoints included overall survival and morbidity after 30 days. In 12 patients, follow-up computed tomography angiogram (CTA) was available and aortic remodeling was evaluated. RESULTS: We identified 16 eligible patients (75% men, mean age: 69 years, range: 52-80 years). Technical success was 94%. Overall survival after 30 days was 100%; there was 1 aortic reintervention (additional false lumen embolization due to endoleak type 1a in 1 patient). Median total follow-up was 31.5 months (range: 3-66 months). Four (25%) of 16 patients died during follow-up, in 3 of those patients the cause of death is unknown, and 1 patient developed cardiac tamponade after being treated by fenestrated thoracic endovascular aortic repair. Imaging follow-up with CTA was available in 12 patients (median imaging follow-up: 27.5 months, range: 1-57 months). Nine (75%) of 12 patients showed thoracic aortic remodeling, and in 3 patients aneurysm size was stable. No patient showed aneurysm growth. CONCLUSION: The Knickerbocker Technique is a feasible endovascular fenestration method to achieve false lumen occlusion and aortic remodeling in chronic aortic dissection with low invasiveness.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Idoso , Feminino , Prótese Vascular , Resultado do Tratamento , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Estudos Retrospectivos , Stents
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA