Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
J Cardiovasc Electrophysiol ; 33(1): 93-101, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34837431

RESUMO

INTRODUCTION: Electromagnetic interference (EMI) from left ventricular assist devices (LVADs) can cause implantable cardioverter-defibrillator (ICD) oversensing. We sought to assess the frequency of inappropriate shocks/oversensing due to LVAD-related EMI and prospectively compare integrated (IB) versus dedicated bipolar (DB) sensing in patients with LVADs. METHODS: Single-center study in LVAD patients with Medtronic or Abbott ICDs between September 2017 and March 2020. We excluded patients that were pacemaker dependent. Measurements were obtained of IB and DB sensing and noise to calculate a signal-to-noise ratio (SNR). Device checks were reviewed to assess appropriate and inappropriate sensing events. RESULTS: Forty patients (age 52 ± 14 years, 75% men, 38% ischemic cardiomyopathy) were included with the median time between LVAD implantation and enrollment of 6.7 months (2.3, 11.4 months). LVAD subtypes included: HeartWare (n = 22, 55%), Heartmate II (n = 10, 25%), and Heartmate III (n = 8, 20%). Over a follow-up duration of 21.6 ± 12.9 months after LVAD implantation, 5% of patients (n = 2) had oversensing of EMI from the LVAD (both with HeartWare LVADs and Abbott ICDs) at 4 days and 10.8 months after LVAD implantation. Both patients underwent adjustment of ventricular sensing with resolution of oversensing and no further events over 5 and 15 months of further follow-up. The SNR was similar between IB and DB sensing (50 [29-67] and 57 [41-69], p = 0.89). CONCLUSION: ICD oversensing of EMI from LVADs is infrequent and can be managed with reprogramming the sensitivity. There was no significant difference in the R-wave SNR with IB versus DB ICD leads.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Coração Auxiliar , Pré-Escolar , Fenômenos Eletromagnéticos , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Ventrículos do Coração , Coração Auxiliar/efeitos adversos , Humanos , Masculino
2.
Curr Opin Cardiol ; 37(1): 22-29, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34620737

RESUMO

PURPOSE OF REVIEW: Atrial fibrillation is a growing public health problem and is associated with an increased risk of comorbidities with enormous socioeconomic implications. This review article focuses on fiscal burden of atrial fibrillation on the healthcare system and economic value of atrial fibrillation ablations brought to the patient and the payers by improvement in outcomes and reduction in treatment costs. RECENT FINDINGS: This article summarizes the recently published studies evaluating the economic impact of atrial fibrillation treatment. Catheter ablation have shown to be the most successful strategy for treatment of defibrillation. However, repeat ablation is associated with higher costs, over and above any subsequent procedural costs, compared with a single ablation procedure for atrial fibrillation. Cryoballoon ablation has been shown to have fewer repeat ablations than radiofrequency ablations, which resulted in overall cost reduction. Improvement in laboratory efficiency, better utilization of laboratory resources and same-day discharge strategy can lead to further healthcare savings and increase in value to all stakeholders. SUMMARY: The value of healthcare delivery for patient with atrial fibrillation can be improved by advancement in technology that demonstrates cost reduction to the health system and outcomes improvements. Implementation of tactics that decrease cost and improve outcomes can alleviate some of the financial strain on healthcare systems, which is of extreme importance in the current climate.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Humanos , Resultado do Tratamento
3.
Pacing Clin Electrophysiol ; 45(2): 204-211, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34978089

RESUMO

BACKGROUND: Patients with left ventricular assist devices (LVAD) often tolerate ventricular arrhythmias (VA). We aim to assess the frequency and outcomes of ICD therapies averted by ultraconservative ICD programming (UCP) in LVAD patients. METHODS: This single center, retrospective cohort study included patients with LVADs and ICDs implanted from 2015 to 2019 that had UCP. The aim for UCP was to maximally delay VA treatments and maximize anti-tachycardia pacing (ATP) prior to ICD shocks. VA events were reviewed after UCP and evaluated under prior conservative programming to assess for potentially averted events (that would have resulted in either ATP or defibrillation with prior programming). RESULTS: Fifty patients were included in the study with follow-up of median 16 ± 10.2 months after UCP. The median time from LVAD implantation to reprogramming was 7 days (IQR 5-9 days). Fourteen patients (28%) had potentially averted VA events that would have been treated with their prior ICD programming (82 total events, median two events per patient, IQR 1-10 events). Treated VA events occurred in 15 patients (30%). Eleven of the 14 patients with potentially averted VAs had treated events as well. Only one patient reported definitive symptoms of self-limited "dizziness" during a potentially averted event that did not result in hospitalization. No patients died of complications from or needed emergent care/hospitalization due a potentially averted VA. CONCLUSIONS: UCP in LVAD patients likely prevented unnecessary VA treatments in many patients with minimal reported symptoms during these potentially averted events. Prospective studies are necessary to confirm these findings.


Assuntos
Desfibriladores Implantáveis , Coração Auxiliar , Taquicardia Ventricular/prevenção & controle , Taquicardia Ventricular/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevenção Primária , Estudos Retrospectivos
4.
J Cardiovasc Electrophysiol ; 32(2): 183-190, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33345408

RESUMO

BACKGROUND: It is common practice to observe patients during an overnight stay (ONS) following a catheter ablation procedure for the treatment of atrial fibrillation (AF). OBJECTIVES: To investigate the safety and economic impact of a same-day discharge (SDD) protocol after cryoballoon ablation for treatment of AF in high-volume, geographically diverse US hospitals. METHODS: We retrospectively reviewed 2374 consecutive patients (1119 SDD and 1180 ONS) who underwent cryoballoon ablation for AF at three US centers. Baseline characteristics, acute procedure-related complications, and longer-term evaluations of safety were recorded during routine clinical follow-up. The mean cost of an ONS was used in a one-way sensitivity analysis to evaluate yearly cost savings as a function of the percentage of SDD cases per year. RESULTS: The SDD and ONS cohorts were predominately male (69% vs. 67%; p = .3), but SDD patients were younger (64 ± 11 vs. 66 ± 10; p < .0001) with lower body mass index (30 ± 6 vs. 31 ± 61; p < .0001) and CHA2 DS2 -VASc scores (1.4 ± 1.0 vs. 2.2 ± 1.4; p < .0002). There was no difference between SDD and ONS in the 30-day total complication rate (n = 15 [1.26%] versus n = 24 [2.03%]; p = .136, respectively). The most common complication was hematoma in both the SDD (n = 8; 0.67%) and ONS (n = 11; 0.93%) cohorts. Sensitivity analysis demonstrated that when 50% of every 100 patients treated were discharged the same day, hospital cost savings ranged from $45 825 to $83 813 per year across US hospitals. CONCLUSIONS: SDD following cryoballoon ablation for AF appears to be safe and is associated with cost savings across different US hospitals.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Humanos , Masculino , Alta do Paciente , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 30(12): 2849-2857, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31596044

RESUMO

BACKGROUND: Left atrial appendage closure (LAAC) with LARIAT has emerged as one of the alternatives to oral anticoagulation (OAC) in patients with nonvalvular atrial fibrillation (AF). Our aim was to study long-term outcomes in patients undergoing LARIAT procedure. METHODS: We analyzed patients screened for LARIAT device in four centers between December 2009 and June 2012. Out of these, patients who didn't undergo LAAC with the LARIAT device due to unfavorable LAA morphology and other preprocedural contraindications were included in control group. We analyzed thromboembolism, bleeding events, and mortality between LAA and control group. RESULTS: About 153 patients were screened. Out of these, 108 (70.6%) patients underwent LARIAT placement (LAA arm) and 45 (29.4%) excluded patients were included in control arm. There were no differences in CHADS2 and CHA2 DS2 -VASc score. Mean HAS-BLED score was significantly higher in the LARIAT group (3.5 ± 1.06 vs 3.09 ± 1.22, P = .04). Mean follow-up time (in years) was 6.56 ± 0.84 in LAA and 6.5 ± 1.26 in control arm. During follow-up period, the LARIAT group was associated with significantly less thromboembolic events (1.9% vs 24%, P < .001), bleeding events (9.2% vs 24.4%, P = .03), and mortality (5.6% vs 20%, P = .01) as compared with the control group. CONCLUSIONS: Long-term data from routine clinical practice from our study suggests that LAA exclusion with LARIAT device is an effective treatment in management of nonvalvular AF patients with high risk of stroke, bleeding, and mortality. Further randomized trials, such as aMAZE, will provide more insight in this expanding field.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Procedimentos Cirúrgicos Cardíacos/instrumentação , Frequência Cardíaca , Potenciais de Ação , Idoso , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Fibrilação Atrial/fisiopatologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/mortalidade , Feminino , Fibrinolíticos/administração & dosagem , Hemorragia/mortalidade , Hemorragia/prevenção & controle , Humanos , Incidência , Ligadura , Masculino , Pessoa de Meia-Idade , Polônia , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/mortalidade , Acidente Vascular Cerebral/prevenção & controle , Tromboembolia/mortalidade , Tromboembolia/prevenção & controle , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
6.
J Cardiovasc Electrophysiol ; 29(1): 5-13, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28988455

RESUMO

BACKGROUND: Percutaneous left atrial appendage closure (LAAC) is a viable option for AF patients who are unable to tolerate long-term oral anticoagulation (OAC). OBJECTIVE: We sought to assess the safety of two commonly used percutaneous devices for LAA closure in the United States by analysis of surveillance data from the FDA Manufacturer and User Facility Device Experience (MAUDE) database. METHODS: The MAUDE database was queried between May 1, 2006 and May 1, 2016 for LARIAT® (SentreHEART Inc., Redwood City, CA, USA) and WATCHMAN™ (Boston Scientific Corp., Marlborough, MA, USA) devices. Among 622 retrieved medical device reports, 356 unique and relevant reports were analyzed. The cumulative incidence of safety events was calculated over the study period and compared between the two devices. RESULTS: LAAC was performed with LARIAT in 4,889 cases. WATCHMAN was implanted in 2,027 patients prior to FDA approval in March 2015 and 3,822 patients postapproval. The composite outcome of stroke/TIA, pericardiocentesis, cardiac surgery, and death occurred more frequently with WATCHMAN (cumulative incidence, 1.93% vs. 1.15%; P = 0.001). The same phenomenon was observed when comparing the WATCHMAN pre- and postapproval experiences for the composite outcome, as well as device embolization, cardiac surgery, and myocardial infarction. CONCLUSIONS: MAUDE-reported data show that postapproval, new technology adoption is fraught with increased complications. Improved collaboration between operators, device manufacturers, and regulators can better serve patients through increased transparency and practical postmarket training and monitoring mechanisms.


Assuntos
Apêndice Atrial/fisiopatologia , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Potenciais de Ação , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Fibrilação Atrial/fisiopatologia , Função do Átrio Esquerdo , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Bases de Dados Factuais , Desenho de Equipamento , Frequência Cardíaca , Humanos , Segurança do Paciente , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , United States Food and Drug Administration
7.
Pacing Clin Electrophysiol ; 41(7): 799-806, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29659027

RESUMO

BACKGROUND: The safety of perioperative anticoagulation (AC) and antiplatelet (AP) therapy with subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation is unknown. The purpose of this study was to identify the risk factors associated with hematoma complicating S-ICD implantation. METHODS: Records were retrospectively reviewed from 200 consecutive patients undergoing S-ICD implantation at two academic medical centers. A hematoma was defined as a device site blood accumulation requiring surgical evacuation, extended hospital stay, or transfusion. RESULTS: Among 200 patients undergoing S-ICD implantation (age 49 ± 17 years, 67% men), 10 patients (5%) had a hematoma, which required evacuation in six patients (3%). Warfarin was bridged or uninterrupted in 12 and 13 patients, respectively (6% and 6.5%). Four of 12 patients with warfarin and bridging AC (33%) and two of 13 patients with uninterrupted warfarin (15%) developed a hematoma. Neither of the two patients with uninterrupted DOAC had a hematoma. No patients on interrupted AC without bridging (n = 26, 13 with warfarin, 13 with DOAC) developed a hematoma. A hematoma was also more likely with the use of clopidogrel (n = 4/10 vs 10/190, 40% vs 5.3%, P < 0.0001) in combination with aspirin in 12/14 patients. Any bridging AC (odds ratio [OR] 10.3, 1.8-60.8, P = 0.01), clopidogrel (OR 10.0, 1.7-57.7, P = 0.01), and uninterrupted warfarin without bridging (OR 11.1, 1.7-74.3, P = 0.013) were independently associated with hematoma formation. CONCLUSION: AC and/or AP therapy with clopidogrel appears to increase the risk for hematoma following S-ICD implantation. Interruption of AC without bridging should be considered when it is an acceptable risk to hold AC.


Assuntos
Anticoagulantes/efeitos adversos , Aspirina/efeitos adversos , Clopidogrel/efeitos adversos , Desfibriladores Implantáveis , Hematoma/induzido quimicamente , Hematoma/epidemiologia , Inibidores da Agregação Plaquetária/efeitos adversos , Complicações Pós-Operatórias/induzido quimicamente , Complicações Pós-Operatórias/epidemiologia , Varfarina/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Implantação de Prótese/métodos , Estudos Retrospectivos , Fatores de Risco
8.
J Cardiovasc Electrophysiol ; 28(8): 853-861, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28497899

RESUMO

BACKGROUND: A significant proportion of patients treated with warfarin for atrial fibrillation (AF) become warfarin ineligible (WI) due to major bleeding events (MBE) or systemic thromboembolism (STE). We report a large multicenter real-world experience of the use of direct oral antagonists (DOACs) in these WI patients. METHODS: We report the outcomes of 263 WI patients treated with DOACs. The primary objective was to evaluate clinical outcomes of STE and MBE with DOACs. Secondary objective was to assess clinical predictors of repeat MBE and STE on DOACs. RESULTS: Note that 63% (166 of 263) patients had a repeat MBE on DOACs. Repeat MBE was significantly higher in patients with prior gastrointestinal bleeding (74.5% vs. 30%, P < 0.0001). Five percent (12 of 263) developed repeat STE. Higher mean CHA2DS2VASC (6.5 ± 1.7 vs. 3.3 ± 1.6 = 0.001) score was associated with repeat STE. About 34% (57 of 166) of patients had an intervention to manage repeat MBE. LAAO devices were successfully used in 67% (12 of 18) high-risk patients who underwent major interventions to manage MBE. CONCLUSION: In WI patients rechallenged with DOACs, a significant proportion developed repeat MBE. LAAO devices seem reasonable in those patients who undergo major interventions to manage MBE with cautious and temporary continuation of DOAC.


Assuntos
Anticoagulantes/administração & dosagem , Fibrilação Atrial/epidemiologia , Substituição de Medicamentos , Hemorragia/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Varfarina/administração & dosagem , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Substituição de Medicamentos/efeitos adversos , Feminino , Seguimentos , Hemorragia/induzido quimicamente , Hemorragia/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/induzido quimicamente , Acidente Vascular Cerebral/diagnóstico , Falha de Tratamento , Varfarina/efeitos adversos
9.
J Cardiovasc Electrophysiol ; 28(2): 139-146, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27943538

RESUMO

BACKGROUND: There have been an increasing number of atrial fibrillation (AF) patients with Watchman left atrial appendage occlusion (LAAO) device, requiring catheter ablation (CA) for maintenance of normal sinus rhythm. In this study, we describe our experience with the feasibility and safety of CA in patients with a preexisting Watchman LAAO device. METHODS: This was a retrospective multicenter AF registry of 60 patients with Watchman LAAO device who underwent CA for AF. Baseline clinical and procedural characteristics of the included subjects were retrieved from review of medical records and were analyzed. RESULTS: The mean age was 72.7 ± 4.9 years and the mean CHADS2 score was 2.3 ± 0.6. All patients had successful pulmonary vein isolation (PVI). The left atrial appendage (LAA) was electrically active in 34 (56%) while reentrant tachycardia and AF triggers were seen in 17 (28%) patients. Electrical isolation was attempted in these 17 patients with only 10 achieving complete LAA isolation. Repeat imaging showed new peri-device leaks in 30% (12/40) patients, while new significant peri-device leaks (≥5 mm) were noted in 10% (10/40) of patients after RFA, respectively, requiring continuation of oral anticoagulation. There were a higher proportion of patients with severe peri-device leaks (≥5 mm) after LAA isolation. However, >50% of those leaks sealed off on follow-up transesophageal echocardiogram. CONCLUSION: AF ablation is a feasible and safe in patients with preexisting Watchman LAAO device. Electrical isolation of the LAA could be difficult and when attempted can result in increased risk of short-term peri-device leak and recurrence of AT/AF in almost all patients.


Assuntos
Apêndice Atrial , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/instrumentação , Ablação por Cateter , Comunicação Interatrial/terapia , Dispositivo para Oclusão Septal , Potenciais de Ação , Idoso , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Ablação por Cateter/efeitos adversos , Ecocardiografia , Técnicas Eletrofisiológicas Cardíacas , Estudos de Viabilidade , Feminino , Frequência Cardíaca , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/fisiopatologia , Humanos , Masculino , Desenho de Prótese , Recidiva , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
10.
Curr Opin Cardiol ; 32(1): 27-38, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27898435

RESUMO

PURPOSE OF REVIEW: The authors reviewed the seminal and more recent literature surrounding the major modalities for percutaneous left atrial appendage closure used in contemporary practice, with particular emphasis on safety and efficacy, technical challenges, and future developments. RECENT FINDINGS: Along with the continued practice of surgical left atrial appendage closure, which has evolved substantially with the advent of clipping techniques, a number of percutaneous methods have been developed to close the left atrial appendage with endocardial, epicardial, and hybrid approaches. The last 18 months has seen the Food and Drug Administration approval of the WATCHMAN device for stroke prevention in the United States, the initiation of a randomized controlled trial to further examine the LARIAT device, and an increasing body of literature surrounding use of the AMPLATZER Amulet in Europe. SUMMARY: Left atrial appendage closure is a promising alternative to systemic anticoagulation for stroke prevention in appropriate atrial fibrillation patients. The wealth of available data for the various modalities sheds light on the strengths and limitations of each, postprocedural complications and their management, and new areas for exploration. With a plethora of new devices on the horizon, it is a very exciting time in the field of 'appendage-ology' as we pursue new avenues to optimize care for atrial fibrillation patients.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/terapia , Cateterismo Cardíaco , Acidente Vascular Cerebral/prevenção & controle , Anticoagulantes/administração & dosagem , Anticoagulantes/uso terapêutico , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Europa (Continente) , Humanos , Próteses e Implantes , Ensaios Clínicos Controlados Aleatórios como Assunto , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
11.
Curr Cardiol Rep ; 18(4): 32, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26915010

RESUMO

Revascularization in stable ischemic heart disease (SIHD) is indicated in patients on optimal medical therapy with angina and/or demonstrable ischemia and a significant stenosis in one or more epicardial coronary arteries. Angiography alone, however, cannot accurately determine the hemodynamic significance of coronary lesions, particularly those of intermediate stenosis severity. A lesion may appear significant on coronary angiogram but may not have functional significance. Percutaneous coronary intervention (PCI) of functionally insignificant coronary artery lesions may have serious consequences; therefore, judicious decision-making in the cardiac catheterization laboratory is indicated. For this reason, it is becoming increasingly important to show that a stenosis is capable to induce myocardial ischemia prior to intervention. Fractional flow reserve (FFR) has emerged as a useful tool for this purpose. In this review, we will briefly discuss the principle of FFR, current evidence and rationale supporting its use, and comparison with other modalities.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Estenose Coronária/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea/normas , Angiografia Coronária/métodos , Ponte de Artéria Coronária , Hemodinâmica , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
12.
Circulation ; 129(23): 2371-9, 2014 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-24842943

RESUMO

BACKGROUND: Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia. The associated morbidity and mortality make AF a major public health burden. Hospitalizations account for the majority of the economic cost burden associated with AF. The main objective of this study is to examine the trends of AF-related hospitalizations in the United States and to compare patient characteristics, outcomes, and comorbid diagnoses. METHODS AND RESULTS: With the use of the Nationwide Inpatient Sample from 2000 through 2010, we identified AF-related hospitalizations using International Classification of Diseases, 9th Revision, Clinical Modification code 427.31 as the principal discharge diagnosis. Overall AF hospitalizations increased by 23% from 2000 to 2010, particularly in patients ≥65 years of age. The most frequent coexisting conditions were hypertension (60.0%), diabetes mellitus (21.5%), and chronic pulmonary disease (20.0%). Overall in-hospital mortality was 1%. The mortality rate was highest in the group of patients ≥80 years of age (1.9%) and in the group of patients with concomitant heart failure (8.2%). In-hospital mortality rate decreased significantly from 1.2% in 2000 to 0.9% in 2010 (29.2% decrease; P<0.001). Although there was no significant change in mean length of stay, mean cost of AF hospitalization increased significantly from $6410 in 2001 to $8439 in 2010 (24.0% increase; P<0.001). CONCLUSIONS: Hospitalization rates for AF have increased exponentially among US adults from 2000 to 2010. The proportion of comorbid chronic diseases has also increased significantly. The last decade has witnessed an overall decline in hospital mortality; however, the hospitalization cost has significantly increased.


Assuntos
Fibrilação Atrial/mortalidade , Fibrilação Atrial/terapia , Custos de Cuidados de Saúde , Hospitalização/tendências , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/economia , Comorbidade , Estudos Transversais , Feminino , Planejamento em Saúde , Insuficiência Cardíaca/mortalidade , Mortalidade Hospitalar/tendências , Hospitalização/economia , Hospitalização/estatística & dados numéricos , Humanos , Tempo de Internação/economia , Tempo de Internação/estatística & dados numéricos , Tempo de Internação/tendências , Masculino , Pessoa de Meia-Idade , Estados Unidos/epidemiologia , Adulto Jovem
13.
Am J Cardiol ; 218: 94-101, 2024 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-38452840

RESUMO

Recent American College of Cardiology (ACC), American Heart Association (AHA), American College of Clinical Pharmacy (ACCP), and Heart Rhythm Society (HRS) guidelines suggest that patients with atrial fibrillation (AF) at intermediate to low annual risk of ischemic stroke can benefit from consideration of factors that might modify their risk of stroke. The role of nontraditional risk factors, such as primary hyperparathyroidism (PHPT), remains unexplored. In our study, we investigated the potential association between PHPT and the risk of ischemic stroke in patients with AF. Using data from the Nationwide Inpatient Sample Database, a retrospective cohort study focused on the adult population with AF, we stratified the participants based on PHPT presence. Demographic information, co-morbidities, and hospitalization details were extracted using International Classification of Diseases, Tenth revision codes. Propensity score matching was applied, encompassing over 20 confounding variables, including the risk factors outlined in the CHA2DS2-VASc (Congestive heart failure (C), Hypertension (H), Age ≥75 years (A2), Diabetes Mellitus (D), Stroke/Transient Ischemic Attack (TIA)/Thromboembolism (S2), Vascular disease (V), Age 65-74 years (A), Sex category [female] (Sc)) score. Multivariate logistic regression analysis was performed after matching to assess the independent impact of PHPT as an ischemic stroke risk factor. A total of 2,051 of the identified 395,249 patients with AF had PHPT. The PHPT group had an average age of 74 years and consisted of more women (66.1% vs 53.0%). After matching, it was observed that the PHPT group had longer hospital stays (5 vs 4 days) and higher hospitalization charges ($45,126 vs $36,644). This group exhibited higher rates of ischemic stroke (6.0% vs 4.4%) and mortality (6.3% vs 4.9%). The adjusted outcomes showed a 1.4-fold increased risk for ischemic stroke and a 1.32-fold increased risk for mortality in the PHPT cohort. The subgroup analysis showed a higher incidence of mortality in men with a high CHA2DS2-VASc score. In conclusion, this study highlights a marked association between PHPT and ischemic stroke in patients with AF, independent of the conventional CHA2DS2-VASc score. The potential mechanisms implicated include vascular changes, cardiac dysfunction, and coagulation cascade alterations. The presence of PHPT should be taken into consideration when deciding the assessment of thromboembolic risk.


Assuntos
Fibrilação Atrial , Hiperparatireoidismo Primário , AVC Isquêmico , Acidente Vascular Cerebral , Tromboembolia , Masculino , Adulto , Humanos , Feminino , Idoso , Fibrilação Atrial/complicações , Estudos Retrospectivos , Hiperparatireoidismo Primário/complicações , Medição de Risco , Acidente Vascular Cerebral/epidemiologia , Fatores de Risco , Tromboembolia/epidemiologia , AVC Isquêmico/complicações , Anticoagulantes
14.
J Thromb Thrombolysis ; 36(2): 175-86, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23605999

RESUMO

Atrial fibrillation (AF) is the most prevalent arrhythmia in United States. Patients with AF are at increased risk of thromboembolic events. This risk is even higher with cardioversion and ablation, especially during periprocedural period. Conventional approaches using heparin and warfarin have been successfully studied to mitigate thromboembolic risk. However, these approaches are with certain inherent limitations. The advent of new target specific oral anticoagulants (TSOAs) may overcome some of the impediments of conventional therapies and provide an alternative for anticoagulation for cardioversion and AF ablation. We will review the role of the new TSOAs in the current anticoagulation strategies to reduce the risk of thromboembolic events associated with cardioversion and AF ablation.


Assuntos
Anticoagulantes/uso terapêutico , Fibrilação Atrial/terapia , Ablação por Cateter , Sistemas de Liberação de Medicamentos , Cardioversão Elétrica , Tromboembolia/prevenção & controle , Administração Oral , Anticoagulantes/efeitos adversos , Humanos
15.
J Interv Card Electrophysiol ; 61(1): 19-27, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32451798

RESUMO

PURPOSE: Idiopathic junctional ectopic tachycardia (JET) is typically refractory to antiarrhythmic agents. Catheter ablation for JET is feasible but is associated with high risk of unintended atrioventricular (AV) block. There is limited data on the appropriate procedural technique and clinical outcomes with catheter ablation for idiopathic JET in adults. METHODS: This is a multicenter, retrospective study of all adult patients (age ≥ 18 years) who underwent catheter ablation for idiopathic JET. Patient, procedural characteristics, and long-term outcomes were evaluated. RESULTS: Fifteen patients [radiofrequency ablation (RF) = 14 and cryoablation = 1) were treated with catheter ablation. The median age was 58 years with 67% males. All patients underwent mapping of the right atrium and the aortic cusps prior to energy delivery. The location of earliest activation in relation to the atrioventricular (AV) node was postero-superior in 73% (11/15), posterior in 13% (2/15), and superior in 13% (2/15) respectively. Acute success was 100%. Arrhythmia recurrence occurred in 53% (8/15) all of whom underwent a repeat ablation. High-grade AV block requiring permanent pacemaker occurred in 20% (3/15). At 12-month follow-up in the redo-ablation group, 37.5% (3/8) had recurrence of the arrhythmia two of which underwent a third ablation procedure. CONCLUSION: Catheter ablation of idiopathic JET in adults is associated with a high rate of recurrence requiring multiple procedures and high risk of AV block requiring a permanent pacemaker. Mapping and ablation of the non-coronary cusp can be considered as the arrhythmia was controlled in 3 patients with no inadvertent AV block.


Assuntos
Ablação por Cateter , Criocirurgia , Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Ectópica de Junção , Adulto , Nó Atrioventricular/cirurgia , Feminino , Humanos , Recém-Nascido , Masculino , Estudos Retrospectivos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico por imagem , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Ectópica de Junção/diagnóstico por imagem , Taquicardia Ectópica de Junção/cirurgia
16.
J Interv Card Electrophysiol ; 57(3): 409-416, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31863251

RESUMO

BACKGROUND: Electrical isolation of the left atrial appendage (LAA) may provide incremental benefits for arrhythmia management in patients undergoing radiofrequency ablation (RFA) for persistent atrial fibrillation (AF). OBJECTIVE: The aim of this study was to compare efficacy and safety of endocardial ablation and LAA exclusion with LARIAT device for electrical and mechanical exclusion of LAA. METHODS: We compared patients who underwent endocardial LAA isolation during index RFA for persistent AF and underwent a repeat RFA to patients who underwent LAA exclusion with LARIAT device followed by RFA for AF in this multicenter registry. Efficacy of electrical and mechanical isolation of LAA was assessed. RESULTS: We included 182 patients of which 91 patients underwent endocardial LAA isolation during RFA for AF, and 91 patients underwent LAA exclusion with LARIAT device followed by RFA for AF. Baseline characteristics were similar except for higher CHA2DS2-VASc score, coronary artery disease, and prior stroke rate in LARIAT arm. Persistence of electrical isolation (measured at beginning of second procedure) after LARIAT procedure was higher than one-time AF-RFA (96.7% vs 52.8%, p < 0.01). Acute pulmonary vein isolation rates were similar in both arms. AF recurrence rate after second isolation attempts at 1 year was similar in both arms. No difference in major complications was noted between both arms. CONCLUSIONS: LAA exclusion with LARIAT device appears to be more efficacious as compared to one-time endocardial ablation, but not compared to repeat isolation, in achieving complete electrical isolation of LAA for persistent AF.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Ablação por Radiofrequência/métodos , Idoso , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/fisiopatologia , Mapeamento Epicárdico , Feminino , Humanos , Ligadura/instrumentação , Masculino , Segurança do Paciente , Veias Pulmonares/cirurgia , Estudos Retrospectivos
17.
J Interv Card Electrophysiol ; 58(2): 141-146, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31732839

RESUMO

BACKGROUND: Warfarin is deemed safe compared to bridging with heparin in the peri-procedure setting while implanting cardiac devices. The timing of discontinuation and re-initiation of direct anticoagulant agents (DOACs) such as dabigatran, apixaban, and rivaroxaban in the peri-procedural setting in comparison to warfarin is not well studied. OBJECTIVE: We wanted to compare three DOAC agents with warfarin during cardiac device implantation. METHODS: Consecutive patients on treatment with dabigatran, rivaroxaban, or apixaban (group A) undergoing a cardiac device generator change, upgrade, or new implantation procedure were compared to those on warfarin (group B). Incidence of hematoma, infection, effusion, stroke, and other complications were noted at 1 day, 1 week, and 3 months. RESULTS: A total of 311 patients in group A underwent the above procedures with 73 patients on dabigatran, 153 on rivaroxaban, and 85 on apixaban. There were 467 patients on warfarin in group B. Mean age of the total population was 68 ± 12 years with 67% males and > 80% Caucasians. The last dose of the DOAC was the night prior to the procedure and resumed the night of the procedure (single dose interruption for apixaban and dabigatran and no un-interruption for rivaroxaban). There was no difference noted in the incidence of minor or major hematoma (9% vs 8.5%, p = 0.7). No stroke occurred in either group. CONCLUSION: Use of DOAC agents with transient interruption of one dose is as safe as warfarin in the peri-procedural setting during implantation of cardiac devices.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Dabigatrana/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Piridonas , Rivaroxabana/efeitos adversos , Vitamina K , Varfarina/uso terapêutico
18.
J Atr Fibrillation ; 12(4): 2265, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32435348

RESUMO

BACKGROUND: Manufacturer/federal drug administration (FDA) recommends inpatient initiation of dofetilide with the manufacturer providing an initiation algorithm. The outcomes of algorithm deviation have not been reported outside of clinical trials. OBJECTIVE: We sought to perform a chart review of all the patients admitted for inpatient initiation of dofetilide to report on the incidence of protocol deviations and their implications. METHODS: We performed a retrospective review of all patients over a 15-month periodwho were initiated on dofetilide for the very first time or reinitiated on dofetilide after a break of three months or more at our institution. We assessed data about patients who were given dofetilide without adherence to the protocol (i.e. protocol deviation). RESULTS: A total of 189 patients were included in the study with a median age of 66 ± 9 years. Mean baseline QTc interval was 436 ± 32 msec, and 61% (116/189) were in atrial fibrillation (AF) at the time of dofetilide initiation. In 9% (17/189) of patients, the drug was discontinued due to intolerance or inefficacy. Therapy in 49% (93/189) of patients was noted to deviate from manufacturer recommended protocol with deviations more than once in some patients during the same hospitalization. Baseline QTc exceeding 440 msec(>500msec in conduction abnormalities) was the most frequent deviation (25%; 47/189).Ventricular tachyarrhythmia occurred in 4% (7/189) of patients, did not differ between patients, and occurred with and without protocol deviations (5% vs 2%; p = 0.27). CONCLUSIONS: In our retrospective study, there were frequent deviations from the manufacturer-recommended algorithm guidelines for dofetilideinitation, primarily due to prolonged baseline QTc interval. The impact of these protocol deviations on drug discontinuation was uncertain; however, significant adverse events were higher in the deviation group compared to the group that fully adhered to the protocol. Further multicenter studies are warranted to clarify our findings.

19.
Circ Arrhythm Electrophysiol ; 12(12): e007520, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31838913

RESUMO

BACKGROUND: Premature ventricular contractions are a common clinical presentation that drives further diagnostic workup. We hypothesize the presence of underlying inflammation is often unrecognized in these patients with a potential for continued disease progression if not diagnosed and treated early in the disease course. METHODS: This is a single-center, prospective study including 107 patients with frequent symptomatic premature ventricular contractions (>5000/24 h) and no known ischemic heart disease. Patients underwent a combination of laboratory testing, 18F-fluorodeoxyglucose positron emission tomography scan, cardiac magnetic resonance imaging, and biopsy. Patients were diagnosed with myocarditis based on a multidisciplinary approach and treated with immunosuppressive therapy. RESULTS: The mean age of the cohort was 57±15 years, 41% were males, and left ventricular ejection fraction was 47±11.8%. Positive positron emission tomography scan was seen in 51% (55/107), of which 51% (28/55) had preserved left ventricle function. Based on clinical profile, 18F-fluorodeoxyglucose-positron emission tomography imaging, cardiac magnetic resonance, and histological data 58% patients (32/55) received immunosuppressive therapy alone and 25.4% (14/55) received immunosuppressive therapy and catheter ablation. Optimal response was seen in 67% (31/46) over a mean follow-up of 6±3 months. In patients with left ventricle systolic dysfunction, 37% (10/27) showed an improvement in mean left ventricular ejection fraction of 13±6%. CONCLUSIONS: Approximately 51% of patients presenting with frequent premature ventricular contractions have underlying myocardial inflammation in this cohort. 18F-fluorodeoxyglucose-positron emission tomography scan can be a useful modality for early diagnosis and treatment with immunosuppressive therapy in selected patients can improve clinical outcomes.


Assuntos
Miocardite/complicações , Complexos Ventriculares Prematuros/etiologia , Adulto , Idoso , Biópsia , Ablação por Cateter , Feminino , Fluordesoxiglucose F18/administração & dosagem , Frequência Cardíaca , Humanos , Imunossupressores/uso terapêutico , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Miocardite/diagnóstico , Miocardite/tratamento farmacológico , Miocardite/fisiopatologia , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Compostos Radiofarmacêuticos/administração & dosagem , Recuperação de Função Fisiológica , Sistema de Registros , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Função Ventricular Esquerda , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/cirurgia
20.
Heart Rhythm ; 16(2): 204-212, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30273767

RESUMO

BACKGROUND: Currently, little is known about the onset, natural progression, and management of esophageal injuries after atrial fibrillation (AF) ablation. OBJECTIVES: We sought to provide a systematic review on esophageal injury after AF ablation and identify temporal relationships between various types of esophageal lesions, their progression, and clinical outcomes. METHODS: A comprehensive search of PubMed and Web of Science was conducted until September 21, 2017. All AF ablation patients who underwent upper gastrointestinal endoscopy within 1 week of the procedure were included. Patients with esophageal lesions were classified into 3 types by using our novel Kansas City classification: type 1: erythema; type 2a: superficial ulcers; type 2b: deep ulcers; type 3a: perforation without communication with the atria; and type 3b: perforation with atrioesophageal fistula. RESULTS: Thirty studies met our inclusion criteria. Of the 4473 patients, 3921 underwent upper gastrointestinal evaluation. The overall incidence of esophageal injuries was 15% (570). There were 206 type 1 lesions (36%), 222 type 2a lesions (39%), and 142 type 2b lesions (25%). Six of 142 type 2b lesions (4.2%) progressed further to type 3, of which, 5 were type 3a and 1 was type 3b. All type 1 and type 2a and most type 2b lesions resolved with conservative management. One type 3a and 1 type 3b lesions were fatal. CONCLUSION: Based on our classification, all type 1 and most type 2 lesions resolved with conservative management. A small percentage (4.2% [6 of 142]) of type 2b lesions progressed to perforation and/or fistula formation, and these patients need to be followed closely.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Doenças do Esôfago/etiologia , Esôfago/lesões , Complicações Pós-Operatórias , Ablação por Cateter/métodos , Progressão da Doença , Endoscopia do Sistema Digestório , Doenças do Esôfago/diagnóstico , Esôfago/diagnóstico por imagem , Humanos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA