Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Neurourol Urodyn ; 42(8): 1722-1732, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37555436

RESUMO

PURPOSE: To assess noninferiority of the safety and effectiveness of the Altis® Single Incision Sling (SIS) with standard midurethral transobturator and/or retropubic slings through 36 months in a prospective, longitudinal, nonrandomized US Food and Drug Administration (FDA) 522 cohort study. MATERIALS AND METHODS: Adult females with confirmed predominant stress urinary incontinence (UI) through cough stress test (CST) or urodynamics and failed two noninvasive incontinence therapies. Effectiveness endpoints included objective dryness, negative CST, adverse events, and revision/resurgery through 36 months. The primary effectiveness endpoint was reduction from baseline in 24-h pad weight of ≥50% at 6 months, as requested by the FDA, and is included as a study point in this paper. Primary safety endpoint was rate of related serious adverse events (SAE) through 36 months. Noninferiority margins of 15% and 10% were prespecified for the effectiveness and safety endpoints. Due to the observational nature of the cohort study, a propensity methodology was conducted to assess the effect of potential confounding variables on the primary endpoints between groups. RESULTS: Three hundred fifty-five women underwent the sling procedure (n = 184 Altis; n = 171 Comparator). One hundred fourty (76%) Altis subjects and 101 (59%) Comparator subjects completed follow-up through 36 months. At 36 months, for the effectiveness endpoint, the difference in proportions of -0.005 for Altis versus Comparator (95% confidence interval [CI]: -0.102 to 0.092) was statistically significant (p = 0.002), supporting the hypothesis that Altis is noninferior to Comparator. Furthermore, both groups demonstrated high objective efficacy; in the Altis arm n = 99 (81.8%) subjects were a success, and in the Comparator arm, n = 79 (82.3%) subjects were a success. Additionally, regarding the CST, Altis was found to be noninferior to the Comparator at every study visit, and the rate of negative CST remained above 80% for both groups (p < 0.001). At 36 months, Altis (n = 2; 1.1%) and Comparator (n = 4; 2.3%) subjects experienced a device and/or procedure-related SAE. The difference in proportions of 0.013 for Altis versus Comparator (95% CI: -0.023 to 0.048) was statistically significant (p < 0.001), demonstrating that Altis is noninferior to Comparator with respect to the primary safety endpoint throughout the study. There were 62 (36.3%) retropubic midurethral slings (RMUS), 96 (56.1%) transobturator midurethral slings (TMUS), and 13 (7.6%) SIS slings in the Comparator group. For the 36 month effectiveness endpoint, assessing the noninferiority of Altis versus RMUS and Altis versus TMUS, 99 (81.8%) Altis and 37 (90.2%) RMUS were a success, trending toward statistical significance, however, it cannot be determined to be noninferior (p = 0.092). Ninty-nine (81.8%) Altis and 33 (71.7%) TMUS were a success; this was statistically significant (p < 0.001), demonstrating Altis was noninferior to TMUS. Rates of negative CST were 122 (87.1%) Altis, 40 (93.0%) RMUS (p < 0.001), and 44 (91.7%) TMUS (p < 0.001). CST demonstrated that Altis was noninferior to RMUS and Altis was noninferior to TMUS at 36 months. CONCLUSION: Altis single-incision sling was noninferior to standard midurethral sling for treatment of stress UI, throughout the study and at 36 months. Furthermore, adverse event rates were low.


Assuntos
Slings Suburetrais , Ferida Cirúrgica , Incontinência Urinária por Estresse , Incontinência Urinária , Estados Unidos , Adulto , Feminino , Humanos , Incontinência Urinária por Estresse/cirurgia , Incontinência Urinária por Estresse/etiologia , Estudos de Coortes , Estudos Prospectivos , Incontinência Urinária/etiologia , Slings Suburetrais/efeitos adversos , Ferida Cirúrgica/etiologia
2.
J Minim Invasive Gynecol ; 28(1): 93-99, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32320798

RESUMO

STUDY OBJECTIVE: The aim of the Altis 522 study was to compare the safety and efficacy of the Altis Single-Incision Sling System (SIS) (Coloplast, Minneapolis, MN) with standard midurethral transobturator and/or retropubic slings through 36 months. In this report, we present data through 12 months of follow-up. DESIGN: Postmarket, prospective, multicenter, nonrandomized cohort design. SETTING: The study was performed at 23 hospitals in the United States and Canada. PATIENTS: Adult female patients with stress urinary incontinence (SUI) clinically indicated for an incontinence sling were treated (n = 355). INTERVENTIONS: Altis SIS was compared with any Food and Drug Administration-cleared transobturator or retropubic sling. MEASUREMENTS AND MAIN RESULTS: Collected measures included device- and/or procedure-related serious adverse events, relevant nonserious and all adverse events, and revision surgery. Objective efficacy measures included 24-hour pad weight, dryness (defined as pad weight ≤4.0 g), and cough stress test. Subjective outcome measures included patient global impression of improvement, urogenital distress inventory, Incontinence Impact Questionnaire-Short Form, Surgical Satisfaction Questionnaire, and visual analog scale for pain. At 12 months, 24-hour pad weight success (≥50% reduction), negative cough stress test, patient global impression of improvement, urogenital distress inventory, and Incontinence Impact Questionnaire-Short Form appeared similar between groups. Through 12 months, 2 subjects in the Altis group and 3 subjects in the comparator group experienced a serious device- and/or procedure-related adverse event. In the Altis group, 1 subject (0.5%) experienced a device revision, and 1 subject (0.5%) had the device explanted. In the comparator group, 7 subjects (4.1%) experienced a device revision, and 1 device (0.6%) was explanted before the 12-month visit. The occurrence of relevant nonserious procedure and/or device-related adverse events was similar between groups. CONCLUSION: At 12-months follow-up, safety and efficacy appeared similar between Altis SIS and standard transobturator and retropubic midurethral slings.


Assuntos
Slings Suburetrais , Incontinência Urinária por Estresse/cirurgia , Procedimentos Cirúrgicos Urológicos , Adulto , Idoso , Canadá/epidemiologia , Estudos de Coortes , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Vigilância de Produtos Comercializados , Reoperação/estatística & dados numéricos , Slings Suburetrais/efeitos adversos , Inquéritos e Questionários , Resultado do Tratamento , Estados Unidos/epidemiologia , Incontinência Urinária por Estresse/epidemiologia , Procedimentos Cirúrgicos Urológicos/efeitos adversos , Procedimentos Cirúrgicos Urológicos/instrumentação , Procedimentos Cirúrgicos Urológicos/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA