Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Opt Lett ; 43(11): 2462-2465, 2018 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-29856404

RESUMO

The fifth harmonic of a pulsed Nd:YLF laser has been realized in a cascade of nonlinear crystals with a record efficiency of 30%. Cesium lithium borate is used in a Type-I configuration for sum-frequency mixing of 1053 and 266 nm, producing 211 nm pulses. Flat-topped beam profiles and pulse shapes optimize efficiency. The energies of the fifth harmonic up to 335 mJ in 2.4 ns pulses were demonstrated.

2.
Phys Rev Lett ; 119(22): 227201, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-29286790

RESUMO

We report measurements of optical absorption in the zigzag antiferromagnet α-RuCl_{3} as a function of temperature T, magnetic field B, and photon energy ℏω in the range ∼0.3-8.3 meV, using time-domain terahertz spectroscopy. Polarized measurements show that threefold rotational symmetry is broken in the honeycomb plane from 2 to 300 K. We find a sharp absorption peak at 2.56 meV upon cooling below the Néel temperature of 7 K at B=0 that we identify as the magnetic-dipole excitation of a zero-wave-vector magnon, or antiferromagnetic resonance (AFMR). With the application of B, the AFMR broadens and shifts to a lower frequency as long-range magnetic order is lost in a manner consistent with transitioning to a spin-disordered phase. From a direct, internally calibrated measurement of the AFMR spectral weight, we place an upper bound on the contribution to the dc susceptibility from a magnetic excitation continuum.

3.
Phys Rev Lett ; 118(1): 015001, 2017 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-28106452

RESUMO

We report the first complete set of measurements of a laser-plasma optical system's refractive index, as seen by a second probe laser beam, as a function of the relative wavelength shift between the two laser beams. Both the imaginary and real refractive index components are found to be in good agreement with linear theory using plasma parameters measured by optical Thomson scattering and interferometry; the former is in contrast to previous work and has implications for crossed-beam energy transfer in indirect-drive inertial confinement fusion, and the latter is measured for the first time. The data include the first demonstration of a laser-plasma polarizer with 85%-87% extinction for the particular laser and plasma parameters used in this experiment, complementing the existing suite of high-power, tunable, and ultrafast plasma-based photonic devices.

4.
Phys Rev Lett ; 119(5): 055001, 2017 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-28949745

RESUMO

We present new experiments to study the formation of radiative shocks and the interaction between two counterpropagating radiative shocks. The experiments are performed at the Orion laser facility, which is used to drive shocks in xenon inside large aspect ratio gas cells. The collision between the two shocks and their respective radiative precursors, combined with the formation of inherently three-dimensional shocks, provides a novel platform particularly suited for the benchmarking of numerical codes. The dynamics of the shocks before and after the collision are investigated using point-projection x-ray backlighting while, simultaneously, the electron density in the radiative precursor was measured via optical laser interferometry. Modeling of the experiments using the 2D radiation hydrodynamic codes nym and petra shows very good agreement with the experimental results.

5.
Appl Opt ; 56(24): 6982-6987, 2017 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-29048046

RESUMO

We report a new method using high-stability, laser-driven supercontinuum generation in a liquid cell to calibrate the absolute photon response of fast optical streak cameras as a function of wavelength when operating at fastest sweep speeds. A stable, pulsed white light source based around the use of self-phase modulation in a salt solution was developed to provide the required brightness on picosecond time scales, enabling streak camera calibration in fully dynamic operation. The measured spectral brightness allowed for absolute photon response calibration over a broad spectral range (425-650 nm). Calibrations performed with two Axis Photonique streak cameras using the Photonis P820PSU streak tube demonstrated responses that qualitatively follow the photocathode response. Peak sensitivities were one photon/count above background. The absolute dynamic sensitivity is less than the static by up to an order of magnitude. We attribute this to the dynamic response of the phosphor being lower.

6.
Appl Opt ; 56(30): 8309-8312, 2017 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-29091606

RESUMO

We report on two-photon absorption measurements at 213 nm of deep UV transmissible media, including LiF, MgF2, CaF2, BaF2, sapphire (Al2O3), and high-purity grades of fused-silica (SiO2). A high-stability 24 ps Nd:YAG laser operating at the 5th harmonic (213 nm) was used to generate a high-intensity, long-Rayleigh-length Gaussian focus inside the samples. The measurements of the fluoride crystals and sapphire indicate two-photon absorption coefficients between 0.004 and 0.82 cm/GW. We find that different grades of fused silica performed near identically for two-photon absorption; however, there are differences in linear losses associated with purity. A low two-photon absorption cross section is measured for MgF2, making it an ideal material for the propagation of high-intensity deep UV lasers.

7.
Appl Opt ; 54(36): 10592-8, 2015 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-26837022

RESUMO

We report on the design and testing of a multiwavelength interferometry system for the Orion laser facility based upon the use of self-path matching Wollaston prisms. The use of UV corrected achromatic optics allows for both easy alignment with an eye-safe light source and small (∼ millimeter) offsets to the focal lengths between different operational wavelengths. Interferograms are demonstrated at wavelengths corresponding to first, second, and fourth harmonics of a 1054 nm Nd:glass probe beam. Example data confirms the broadband achromatic capability of the imaging system with operation from the UV (263 nm) to visible (527 nm) and demonstrates that features as small as 5 µm can be resolved for object sizes of 15 by 10 mm. Results are also shown for an off-harmonic wavelength that will underpin a future capability. The primary optics package is accommodated inside the footprint of a ten-inch manipulator to allow the system to be deployed from a multitude of viewing angles inside the 4 m diameter Orion target chamber.

8.
Phys Rev Lett ; 113(3): 035003, 2014 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-25083650

RESUMO

The interpenetration and interaction of supersonic, magnetized tungsten plasma flows has been directly observed via spatially and temporally resolved measurements of the Thomson scattering ion feature. A novel scattering geometry allows independent measurements of the axial and radial velocity components of the ions. The plasma flows are produced via the pulsed power driven ablation of fine tungsten wires in a cylindrical wire array z pinch. Fits of the data reveal the variations in radial velocity, axial velocity, and temperature of the ion streams as they interpenetrate and interact. A previously unobserved increase in axial velocity is measured near the array axis. This may be the result of v[over →]×B[over →] bending of the ion streams by a toroidal magnetic field, advected to and accumulated about the axis by the streams.

9.
Tech Coloproctol ; 18(1): 73-6, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23111401

RESUMO

Presacral bleeding is a dreaded complication of pelvic surgery. Rapid and effective control of such bleeding is important to avoid potentially life-threatening outcomes. Various methods for controlling presacral bleeding, all with only limited success, have been described in the literature. We report the alternative technique of using the argon beam coagulator (ABC) to control presacral bleeding. We demonstrate its efficacious use in both open surgery and a laparoscopic case. Our approach involved applying an argon beam at bone setting directly to the bleeders and using a "point and shoot" technique. We found that ABC is a simpler, equally effective and expeditious way of addressing presacral bleeding. To the best of our knowledge, there has been only one previously reported case in the literature of the use of ABC to control presacral bleeding.


Assuntos
Coagulação com Plasma de Argônio/métodos , Hemostasia Cirúrgica/métodos , Hemorragia Pós-Operatória/terapia , Região Sacrococcígea/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Região Sacrococcígea/irrigação sanguínea
10.
Phys Rev Lett ; 108(14): 145002, 2012 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-22540799

RESUMO

A Thomson scattering diagnostic has been used to measure the parameters of cylindrical wire array Z pinch plasmas during the ablation phase. The scattering operates in the collective regime (α>1) allowing spatially localized measurements of the ion or electron plasma temperatures and of the plasma bulk velocity. The ablation flow is found to accelerate towards the axis reaching peak velocities of 1.2-1.3×10(7) cm/s in aluminium and ∼1×10(7) cm/s in tungsten arrays. Precursor ion temperature measurements made shortly after formation are found to correspond to the kinetic energy of the converging ablation flow.

11.
Mol Biol Cell ; 12(10): 3114-25, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11598196

RESUMO

Serial analysis of gene expression (SAGE) was applied to the malarial parasite Plasmodium falciparum to characterize the comprehensive transcriptional profile of erythrocytic stages. A SAGE library of approximately 8335 tags representing 4866 different genes was generated from 3D7 strain parasites. Basic local alignment search tool analysis of high abundance SAGE tags revealed that a majority (88%) corresponded to 3D7 sequence, and despite the low complexity of the genome, 70% of these highly abundant tags matched unique loci. Characterization of these suggested the major metabolic pathways that are used by the organism under normal culture conditions. Furthermore several tags expressed at high abundance (30% of tags matching to unique loci of the 3D7 genome) were derived from previously uncharacterized open reading frames, demonstrating the use of SAGE in genome annotation. The open platform "profiling" nature of SAGE also lead to the important discovery of a novel transcriptional phenomenon in the malarial pathogen: a significant number of highly abundant tags that were derived from annotated genes (17%) corresponded to antisense transcripts. These SAGE data were validated by two independent means, strand specific reverse transcription-polymerase chain reaction and Northern analysis, where antisense messages were detected in both asexual and sexual stages. This finding has implications for transcriptional regulation of Plasmodium gene expression.


Assuntos
Etiquetas de Sequências Expressas , Perfilação da Expressão Gênica , Expressão Gênica/genética , Oligorribonucleotídeos Antissenso/genética , Plasmodium falciparum/genética , Animais , Galinhas/parasitologia , Eritrócitos/parasitologia , Genoma de Protozoário , Biblioteca Genômica , Estágios do Ciclo de Vida/genética , Estágios do Ciclo de Vida/fisiologia , Malária Falciparum/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Transcrição Gênica/genética
12.
Phys Rev E ; 95(3-1): 033208, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28415195

RESUMO

We report on the detection of the time-dependent B-field amplitude and topology in a laser-driven solenoid. The B-field inferred from both proton deflectometry and Faraday rotation ramps up linearly in time reaching 210 ± 35 T at the end of a 0.75-ns laser drive with 1 TW at 351 nm. A lumped-element circuit model agrees well with the linear rise and suggests that the blow-off plasma screens the field between the plates leading to an increased plate capacitance that converts the laser-generated hot-electron current into a voltage source that drives current through the solenoid. ALE3D modeling shows that target disassembly and current diffusion may limit the B-field increase for longer laser drive. Scaling of these experimental results to a National Ignition Facility (NIF) hohlraum target size (∼0.2cm^{3}) indicates that it is possible to achieve several tens of Tesla.

13.
Drug Deliv Transl Res ; 6(5): 579-96, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27468861

RESUMO

The research envisioned was the development of diltiazem hydrochloride effervescent floating matrix tablet using a risk-based approach. Preliminarily, the in vitro drug release profile was derived which theoretically simulated the in vivo condition after oral administration. Considering this as a rationale, the formulation development was initiated with defining the quality target product profile (QTPP) and critical quality attributes (CQAs). The preliminary studies were conducted to screen material attributes and process parameters followed by their risk assessment studies to select the plausible factors affecting the drug product CQAs, i.e., floating lag time and drug release profile. A 3(2) full factorial design was used to estimate the effect of the amount of swelling polymer (X 1) and gas-generating agent (X 2) on percent drug release (Q t1h and Q t8h) and floating lag time. Response and interaction plots were generated to examine the variables. Selection of an optimized formulation was done using desirability function and further validated. The model diagnostic plots represent the absence of outliers. The optimized formula obtained by the software was further validated, and the result of drug release and floating lag time was close to the predicted values. In a clear and concise way, the current investigations report the successful development of an effervescent floating matrix tablet for twice daily administration of diltiazem hydrochloride.


Assuntos
Preparações de Ação Retardada/química , Diltiazem/química , Sistemas de Liberação de Medicamentos/métodos , Liberação Controlada de Fármacos , Modelos Teóricos , Administração Oral , Preparações de Ação Retardada/administração & dosagem , Diltiazem/administração & dosagem , Diltiazem/farmacocinética , Humanos , Medição de Risco , Solubilidade , Comprimidos
14.
Nat Commun ; 7: ncomms11899, 2016 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-27291065

RESUMO

Astrophysical flows exhibit rich behaviour resulting from the interplay of different forms of energy-gravitational, thermal, magnetic and radiative. For magnetic cataclysmic variable stars, material from a late, main sequence star is pulled onto a highly magnetized (B>10 MG) white dwarf. The magnetic field is sufficiently large to direct the flow as an accretion column onto the poles of the white dwarf, a star subclass known as AM Herculis. A stationary radiative shock is expected to form 100-1,000 km above the surface of the white dwarf, far too small to be resolved with current telescopes. Here we report the results of a laboratory experiment showing the evolution of a reverse shock when both ionization and radiative losses are important. We find that the stand-off position of the shock agrees with radiation hydrodynamic simulations and is consistent, when scaled to AM Herculis star systems, with theoretical predictions.

15.
Rev Sci Instrum ; 86(3): 033502, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25832224

RESUMO

We report on the design, construction, and characterisation of a new class of in-vacuo optical levitation trap optimised for use in high-intensity, high-energy laser interaction experiments. The system uses a focused, vertically propagating continuous wave laser beam to capture and manipulate micro-targets by photon momentum transfer at much longer working distances than commonly used by optical tweezer systems. A high speed (10 kHz) optical imaging and signal acquisition system was implemented for tracking the levitated droplets position and dynamic behaviour under atmospheric and vacuum conditions, with ±5 µm spatial resolution. Optical trapping of 10 ± 4 µm oil droplets in vacuum was demonstrated, over timescales of >1 h at extended distances of ∼40 mm from the final focusing optic. The stability of the levitated droplet was such that it would stay in alignment with a ∼7 µm irradiating beam focal spot for up to 5 min without the need for re-adjustment. The performance of the trap was assessed in a series of high-intensity (10(17) W cm(-2)) laser experiments that measured the X-ray source size and inferred free-electron temperature of a single isolated droplet target, along with a measurement of the emitted radio-frequency pulse. These initial tests demonstrated the use of optically levitated microdroplets as a robust target platform for further high-intensity laser interaction and point source studies.

16.
Mol Biochem Parasitol ; 111(2): 425-35, 2000 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11163448

RESUMO

The Pgs28 protein is a major surface antigen of the sexual stages of Plasmodium gallinaceum the zygotes and the ookinetes. The protein contains conserved motifs, namely an N-terminal signal sequence, four epidermal growth factor-like repeats and a C-terminal hydrophobic domain that serves as a signal for glycosylphosphatidylinositol (GPI)--anchor modification. In this study, we define the protein motifs required for the surface localization of Pgs28 in ookinetes. using transient transfection combined with immunofluorescence and confocal microscopy. Pgs28 fused to the green fluorescent protein (Pgs28-GFP) is expressed in zygotes, intermediate retort forms and ookinetes. Mutational analyses of Pgs28 coding regions reveal that deletions of the signal sequence and the C-terminal domain result in intracellular retention of the fusion protein. Therefore, the signal sequence and C-terminal domain are required for cell surface localization. Additionally, the Pgs28-GFP fusion proteins are shed from the surface of live ookinetes, suggesting that Pgs28 may be involved in interactions with the cells of the mosquito midgut or during motility.


Assuntos
Antígenos de Protozoários , Plasmodium gallinaceum/fisiologia , Sinais Direcionadores de Proteínas/fisiologia , Proteínas de Protozoários/química , Proteínas de Protozoários/metabolismo , Animais , Imunofluorescência , Deleção de Genes , Proteínas de Fluorescência Verde , Proteínas Luminescentes/genética , Proteínas Luminescentes/metabolismo , Microscopia Confocal , Microscopia Imunoeletrônica , Mutação , Organelas/metabolismo , Plasmodium gallinaceum/genética , Plasmodium gallinaceum/crescimento & desenvolvimento , Plasmodium gallinaceum/metabolismo , Estrutura Terciária de Proteína , Proteínas de Protozoários/genética , Proteínas Recombinantes de Fusão/metabolismo , Frações Subcelulares/metabolismo , Transfecção
17.
Mol Biochem Parasitol ; 113(1): 23-34, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11254951

RESUMO

The advent of high-throughput methods for the analysis of global gene expression, together with the Malaria Genome Project open up new opportunities for furthering our understanding of the fundamental biology and virulence of the malaria parasite. Serial analysis of gene expression (SAGE) is particularly well suited for malarial systems, as the genomes of Plasmodium species remain to be fully annotated. By simultaneously and quantitatively analyzing mRNA transcript profiles from a given cell population, SAGE allows for the discovery of new genes. In this study, one reports the successful application of SAGE in Plasmodium falciparum, 3D7 strain parasites, from which a preliminary library of 6880 tags corresponding to 4146 different genes was generated. It was demonstrated that P. falciparum is amenable to this technique, despite the remarkably high A-T content of its genome. SAGE tags as short as 10 nucleotides were sufficient to uniquely identify parasite transcripts from both nuclear and mitochondrial genomes. Moreover, the skewed A-T content of parasite sequence did not preclude the use of enzymes that are crucial for generating representative SAGE libraries. Finally, a few modifications to DNA extraction and cloning steps of the SAGE protocol proved useful for circumventing specific problems presented by A-T rich genomes.


Assuntos
Expressão Gênica/genética , Genoma de Protozoário , Plasmodium falciparum/genética , Animais , Núcleo Celular/genética , DNA Complementar/genética , DNA de Protozoário/genética , Etiquetas de Sequências Expressas , Técnicas Genéticas , Biblioteca Genômica , Mitocôndrias/genética , RNA Mensageiro/genética , Análise de Sequência
18.
Biosci Rep ; 8(5): 435-41, 1988 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-3233342

RESUMO

Digestion of nuclear DNAs of five plants, namely Cucurbita maxima (red gourd), Trichosanthes anguina (snake gourd), Cucumis sativus (cucumber), Cajanus cajan (pigeon pea) and Phaseolus vulgaris (french bean) with the restriction endonuclease MboI yielded discrete size classes with molecular weights in the range of 0.5 to 5 kbp. The MboI digestion pattern of Cot 0.1 DNA in french bean is comparable with that of total DNA, indicating that these bands represented highly repeated DNA sequences. Cleavage of the DNAs with varying amounts of MboI indicated the dispersed nature of the repeat families. Southern hybridization studies using french bean highly repetitive DNA as a probe indicated more homology with repeats of pigeon pea and less homology with red gourd, snake gourd and cucumber repeats.


Assuntos
Plantas/genética , Sequências Repetitivas de Ácido Nucleico , Southern Blotting , Mapeamento por Restrição
19.
Contraception ; 25(3): 243-52, 1982 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-6804162

RESUMO

A randomized double-blind study of two combined oral contraceptives and two progestogen-only oral contraceptives was conducted using the same protocol at WHO Collaborating Centres for Clinical Research in Human Reproduction in Bombay and Ljubljana of the 518 women admitted to the trial, 123 received mestranol 50 micrograms + norethisterone 1mg (MES 50 + NET 1); 137 received ethinyl estradiol 30 micrograms + levonorgestrel 150 micrograms (EE 30 + LNG 150); 130 received norethisterone 350 micrograms/NET 350); and 128 received levonorgestrel 30 micrograms (LNG 30). At one year, between 52.6 and 61.0 percent of those recruited had discontinued oral contraceptive use for all reasons, and by two years, between 70.5 and 76.5 percent had discontinued the treatment. These rates did not differ between the four treatment groups. However, discontinuation rates for all medical reasons at one and two years, and at two years pregnancy rates and discontinuation rates for bleeding disturbances, were significantly lower in the EE/LNG preparation. The groups receiving the MES/NET, LNG and NET had similar pregnancy rates, discontinuation rates for all medical reasons and all bleeding disturbances. There were two ectopic pregnancies among the 22 pregnancies in the progestogen-only groups. Discontinuation because of headache, dizziness and other central nervous system symptoms were significantly more common in those receiving MES/NET compared to EE/LNG. In contrast, discontinuation for gastro-intestinal disturbances were significantly higher in the EE/LNG combined preparation. Bleeding disturbances in the first few cycles tended to be higher in NET than in the LNG group. The data suggest that greater consideration be given to the benefits and risks of including progestogen-only oral contraceptives in the family planning programmes of some countries.


Assuntos
Anticoncepcionais Orais Combinados , Anticoncepcionais Orais Hormonais , Anticoncepcionais Orais , Adolescente , Adulto , Ensaios Clínicos como Assunto , Anticoncepcionais Orais/administração & dosagem , Anticoncepcionais Orais Combinados/administração & dosagem , Anticoncepcionais Orais Hormonais/administração & dosagem , Método Duplo-Cego , Etinilestradiol/administração & dosagem , Feminino , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Levanogestrel , Menstruação/efeitos dos fármacos , Mestranol/administração & dosagem , Noretindrona/administração & dosagem , Norgestrel , Gravidez , Distribuição Aleatória
20.
Med Biol Eng Comput ; 29(5): 482-8, 1991 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-1817209

RESUMO

The goal of this research is to develop a predictive model with good absolute accuracy for blood-gas exchange devices. The proposed model, unlike existing models, is able to predict gas transfer to blood flowing outside oxygenating fibres without experimental data. The proposed model uses a finite-difference numerical technique to solve computationally two-dimensional gas exchange problems such as gas transfer to blood outside hollow fibres. The model is compared to bovine and human experimental data from the small test cells with microporous polypropylene fibres. The test cell flow rates range from 1 m litre min-1 to 5 m litre min-1 for a 72-fibre device. Shear-augmented oxygen diffusion appears to be present, although good accuracy is obtained with a nonaugmented diffusion model, particularly at lower flows. The maximum deviation of oxygen saturation predicted by a shear-augmented bovine blood model from the experimental regression line was 1.7 per cent.


Assuntos
Oxigenação por Membrana Extracorpórea , Modelos Biológicos , Animais , Dióxido de Carbono/sangue , Bovinos , Matemática , Oxigênio/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA