1.
Circulation ; 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38989565

RESUMO

BACKGROUND: Physician modified endografts (PMEGs) have been widely used in the treatment of complex abdominal aortic aneurysm and thoracoabdominal aortic aneurysm, however, previous data are limited to small single center studies and robust data on safety and effectiveness of PMEGs are lacking. We aimed to perform an international multicenter study analyzing the outcomes of PMEGs in complex abdominal aortic aneurysms and thoracoabdominal aortic aneurysms. METHODS: An international multicenter single-arm cohort study was performed analyzing the outcomes of PMEGs in the treatment of elective, symptomatic, and ruptured complex abdominal aortic aneurysms and thoracoabdominal aortic aneurysms. Variables and outcomes were defined according to the Society for Vascular Surgery reporting standards. Device modification and procedure details were collected and analyzed. Efficacy outcomes included technical success and safety outcomes included major adverse events and 30-day mortality. Follow-up outcomes included reinterventions, endoleaks, target vessel patency rates and overall and aortic-related mortality. Multivariable analysis was performed aiming at identifying predictors of technical success, 30-day mortality, and major adverse events. RESULTS: Overall, 1274 patients were included in the study from 19 centers. Median age was 74 (IQR, 68-79), and 75.7% were men; 45.7% were complex abdominal aortic aneurysms, and 54.3% were thoracoabdominal aortic aneurysms; 65.5% patients presented electively, 24.6% were symptomatic, and 9.9% were ruptured. Most patients (83.1%) were submitted to a fenestrated repair, 3.6% to branched repair, and 13.4% to a combined fenestrated and branched repair. Most patients (85.8%) had ≥3 target vessels included. The overall technical success was 94% (94% in elective, 93.4% in symptomatic, and 95.1% in ruptured cases). Thirty-day mortality was 5.8% (4.1% in elective, 7.6% in symptomatic, and 12.7% in ruptured aneurysms). Major adverse events occurred in 25.2% of cases (23.1% in elective, 27.8% in symptomatic, and 30.3% in ruptured aneurysms). Median follow-up was 21 months (5.6-50.6). Freedom from reintervention was 73.8%, 61.8%, and 51.4% at 1, 3, and 5 years; primary target vessel patency was 96.9%, 93.6%, and 90.3%. Overall survival and freedom from aortic-related mortality was 82.4%/92.9%, 69.9%/91.6%, and 55.0%/89.1% at 1, 3, and 5 years. CONCLUSIONS: PMEGs were a safe and effective treatment option for elective, symptomatic, and ruptured complex aortic aneurysms. Long-term data and future prospective studies are needed for more robust and detailed analysis.

2.
J Vasc Surg ; 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38992807

RESUMO

OBJECTIVE: To report outcomes of urgent juxtarenal/pararenal aneurysms (J/P-AAAs) managed by off-the-shelf multibranched thoracoabdominal endografts (Cook, T-branch). METHODS: In this observational, multicenter, retrospective study, patients with J/P-AAAs treated by urgent endovascular repair by T-branch in 23 European aortic centers, from 2013 to 2023, were analyzed. Contained J/P-AAAs rupture, presence of related symptoms, and aneurysm diameter of >70 mm were considered as indication for urgent repair. Technical success (TS), spinal cord ischemia (SCI), and 30-day/hospital mortality were assessed as early outcomes. Survival, freedom from reinterventions, and target artery instability (TAI) were evaluated during follow-up. RESULTS: Overall, 197 patients (J-AAAs, n = 64 [33%]; P-AAAs, n = 95 [48%]; previous failed endovascular aneurysm repair (EVAR), n = 38 [19%]) were analyzed. The mean age and aneurysm diameter was 75 ± 8 years and 76 ± 4 mm, respectively. The American Society of Anesthesiologists score was 3 and 4 in 118 (60%) and 79 (40%) patients. Rupture, symptoms, and diameter of >70 mm were present in 51 (26%), 110 (56%), and 53 (27%) patients, respectively. An adjunctive proximal thoracic endograft was used in 28 cases (14%). The mean aortic coverage between the upper portion of the endograft and the lowest renal artery was 154 ± 49 mm. Single-stage repair and cerebrospinal fluid drainage were reported in 144 (73%) and 53 (27%) cases, respectively. TS was achieved in 182 (92%) cases (rupture, 84% vs no rupture, 95%; P = .02). Failures consist of TA loss (11 [6%]: renal artery, 9; celiac trunk, 2), type I to III endoleaks (2 [1%]), and 24-h mortality (2 [1%]). Rupture was a risk factor for technical failure (P = .02; odds ratio [OR], 3.8; 95% confidence interval [CI], 1.1-12.1). Overall, 15 patients (8%) had persistent SCI (rupture, 14% vs no rupture, 5%) with 11 (6%) , of paraplegia (rupture, 10% vs no rupture, 5%; P = .001). Rupture (P = .04; OR, 3.1; 95% CI, 1.1-8.9) and adjunctive proximal thoracic endograft (P = .01; OR, 4.1; 95% CI, 1.3-12.9) were risk-factors for SCI. Twenty-two patients (11%) died within 30 days or during a prolonged hospitalization. Previous failed EVAR (P = .04; OR, 3.6; 95% CI, 1.1-12.3), paraplegia (P < .001; OR, 9.9; 95% CI, 1.6-62.2) and postoperative mesenteric complications (P = .03; OR, 10.4; 95% CI, 1.2-93.3), as well as cardiac (P = .03; OR, 8.2; 95% CI, 2.0-33.0) and respiratory (P < .001; OR, 10.1; 95% CI, 2.9-35.2) morbidities were associated with 30-day/hospital mortality. The mean follow-up was 19 ± 5 months. The estimated 3-year survival and freedom from reinterventions was 58% and 77%, respectively. TAI occurred in 27 patients (14%) (occlusion, 15; endoleak, 14) with an estimated 3-year freedom from TAI of 72%. CONCLUSIONS: Urgent repair of J/P-AAAs by T-branch is feasible and effective with satisfactory TS and 30-day/hospital mortality in high-risk patients. However, extensive aortic coverage is necessary, leading to a non-negligible SCI rate, especially in case of aortic rupture or when adjunctive thoracic endografts are necessary. Previous failed EVAR and postoperative mesenteric complications, as well as cardiac and respiratory morbidities were associated with 30-day/hospital mortality and should be subjected to more research for the purposes of improving outcomes.

3.
EJVES Vasc Forum ; 61: 99-103, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38560760

RESUMO

Introduction: Horseshoe kidney (HK) is an anatomical variant characterised by abnormalities in the position, rotation, and vascular supply of the kidney, with functioning renal masses on both sides of the vertebral column fused together at the isthmus. Due to the altered pattern of kidney vasculature, endovascular aortic repair for aortic abdominal aneurysm (AAA) in the presence of HK requires vascular anatomy specific planning. Report: A 68 year old male, with multiple comorbidities, presented with an asymptomatic AAA and HK. The kidney vasculature was characterised by the presence of three arteries: two arising laterally at the same level and a third polar artery arising from below. The polar artery was 6 mm in diameter and larger than the other two; therefore, in order to preserve this artery, a custom-made device with a single side branch was implanted below the main renal arteries. A balloon expandable covered stent was used to complete the side branch into the polar renal artery. The follow-up computed tomography angiography revealed a successful outcome, with total aneurysm exclusion, branched graft patency, no endoleak, and unchanged renal function. Discussion: This case report shows a possible surgical solution for a case of HK with AAA and the importance of accurate endovascular planning. Large polar arteries, if present, need to be preserved, and custom-made devices in the modern endovascular era permit that. This approach could represent the best option for complicated patients.