Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Med Device ; 17(1): 011009, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36890857

RESUMO

Emergency medical service (EMS) providers have a higher potential exposure to infectious agents than the general public (Nguyen et al., 2020, "Risk of COVID-19 Among Frontline Healthcare Workers and the General Community: A Prospective Cohort Study," Lancet Pub. Health, 5(9), pp. e475-e483; Brown et al., 2021, "Risk for Acquiring Coronavirus Disease Illness Among Emergency Medical Service Personnel Exposed to Aerosol-Generating Procedures," Emer. Infect. Disease J., 27(9), p. 2340). The use of protective equipment may reduce, but does not eliminate their risk of becoming infected as a result of these exposures. Prehospital environments have a high risk of disease transmission exposing EMS providers to bioaerosols and droplets from infectious patients. Field intubation procedures may be performed causing the generation of bioaerosols, thereby increasing the exposure of EMS workers to pathogens. Additionally, ambulances have a reduced volume compared to a hospital treatment space, often without an air filtration system, and no control mechanism to reduce exposure. This study evaluated a containment plus filtration intervention for reducing aerosol concentrations in the patient module of an ambulance. Aerosol concentration measurements were taken in an unoccupied research ambulance at National Institute for Occupational Safety and Health (NIOSH) Cincinnati using a tracer aerosol and optical particle counters (OPCs). The evaluated filtration intervention was a containment pod with a high efficiency particulate air (HEPA)-filtered extraction system that was developed and tested based on its ability to contain, capture, and remove aerosols during the intubation procedure. Three conditions were tested (1) baseline (without intervention), (2) containment pod with HEPA-1, and (3) containment pod with HEPA-2. The containment pod with HEPA-filtered extraction intervention provided containment of 95% of the total generated particle concentration during aerosol generation relative to the baseline condition, followed by rapid air cleaning within the containment pod. This intervention can help reduce aerosol concentrations within ambulance patient modules while performing aerosol-generating procedures.

2.
Ultrasound Med Biol ; 46(3): 649-659, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31883734

RESUMO

We evaluated the effect of oral molecular iodine supplementation and shock wave application under three different conditions on human MDA-MB231 cancer cell xenografts. After tumor volume reached 1 cm3, mice were randomly assigned to groups and treated for 3 weeks. The results revealed that high-dose shock wave treatment (150 shock waves at a pressure of 21.7 MPa, SW150/21.7) generated tissue lesions without decreasing tumor growth, canceled the antineoplastic action of iodine and promoted pro-tumor conditions (increased hypoxia-induced factor [HIF] and vascular endothelial growth factor [VEGF]). In contrast, moderate (SW35/21.7) and low (SW35/9.9) doses of shock waves had significant antineoplastic effects and, in combination with iodine supplement, attenuated the aggressiveness of these cells by decreasing expression of the markers of stem cells (CD44 and Sox2) and invasion (HIF and VEGF). These results allow us to propose the combination of shock waves and iodine as a possible adjuvant in breast cancer therapy.


Assuntos
Neoplasias da Mama/terapia , Ondas de Choque de Alta Energia/uso terapêutico , Iodo/uso terapêutico , Animais , Terapia Combinada , Feminino , Xenoenxertos , Humanos , Camundongos , Transplante de Neoplasias , Distribuição Aleatória
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA