Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Clin Infect Dis ; 75(4): 723-728, 2022 09 10.
Artigo em Inglês | MEDLINE | ID: mdl-35015842

RESUMO

Testing programs for severe acute respiratory syndrome coronavirus 2 have relied on high-throughput polymerase chain reaction laboratory tests and rapid antigen assays to meet diagnostic needs. Both technologies are essential; however, issues of cost, accessibility, manufacturing delays, and performance have limited their use in low-resource settings and contributed to the global inequity in coronavirus disease 2019 testing. Emerging low-cost, multidisease point-of-care nucleic acid tests may address these limitations and strengthen pandemic preparedness, especially within primary healthcare where most cases of disease first present. Widespread deployment of these novel technologies will also help close long-standing test access gaps for other diseases, including tuberculosis, human immunodeficiency virus, cervical cancer, viral hepatitis, and sexually transmitted infections. We propose a more optimized testing framework based on greater use of point-of-care nucleic acid tests together with rapid immunologic assays and high-throughput laboratory molecular tests to improve the diagnosis of priority endemic and epidemic diseases, as well as strengthen the overall delivery of primary healthcare services.


Assuntos
COVID-19 , Ácidos Nucleicos , COVID-19/diagnóstico , Teste para COVID-19 , Técnicas de Laboratório Clínico , Humanos , Testes Imediatos
2.
PLoS Med ; 19(8): e1004076, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35994520

RESUMO

BACKGROUND: Accurate routine HIV viral load testing is essential for assessing the efficacy of antiretroviral treatment (ART) regimens and the emergence of drug resistance. While the use of plasma specimens is the standard for viral load testing, its use is restricted by the limited ambient temperature stability of viral load biomarkers in whole blood and plasma during storage and transportation and the limited cold chain available between many health care facilities in resource-limited settings. Alternative specimen types and technologies, such as dried blood spots, may address these issues and increase access to viral load testing; however, their technical performance is unclear. To address this, we conducted a meta-analysis comparing viral load results from paired dried blood spot and plasma specimens analyzed with commonly used viral load testing technologies. METHODS AND FINDINGS: Standard databases, conferences, and gray literature were searched in 2013 and 2018. Nearly all studies identified (60) were conducted between 2007 and 2018. Data from 40 of the 60 studies were included in the meta-analysis, which accounted for a total of 10,871 paired dried blood spot:plasma data points. We used random effects models to determine the bias, accuracy, precision, and misclassification for each viral load technology and to account for between-study variation. Dried blood spot specimens produced consistently higher mean viral loads across all technologies when compared to plasma specimens. However, when used to identify treatment failure, each technology compared best to plasma at a threshold of 1,000 copies/ml, the present World Health Organization recommended treatment failure threshold. Some heterogeneity existed between technologies; however, 5 technologies had a sensitivity greater than 95%. Furthermore, 5 technologies had a specificity greater than 85% yet 2 technologies had a specificity less than 60% using a treatment failure threshold of 1,000 copies/ml. The study's main limitation was the direct applicability of findings as nearly all studies to date used dried blood spot samples prepared in laboratories using precision pipetting that resulted in consistent input volumes. CONCLUSIONS: This analysis provides evidence to support the implementation and scale-up of dried blood spot specimens for viral load testing using the same 1,000 copies/ml treatment failure threshold as used with plasma specimens. This may support improved access to viral load testing in resource-limited settings lacking the required infrastructure and cold chain storage for testing with plasma specimens.


Assuntos
Infecções por HIV , HIV-1 , Teste em Amostras de Sangue Seco/métodos , Infecções por HIV/diagnóstico , Infecções por HIV/tratamento farmacológico , HIV-1/genética , Humanos , RNA Viral , Sensibilidade e Especificidade , Carga Viral/métodos
3.
J Clin Microbiol ; 54(8): 2104-8, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27252459

RESUMO

Viral load testing is the WHO-recommended monitoring assay for patients on HIV antiretroviral therapy (ART). Point-of-care (POC) assays may help improve access to viral load testing in resource-limited settings. We compared the performance of the Alere Q NAT POC viral load technology (Alere Technologies, Jena, Germany), measuring total HIV RNA using finger prick capillary whole-blood samples collected in a periurban health center, with that of a laboratory-based plasma RNA test (Roche Cobas Ampliprep/Cobas TaqMan v2) conducted on matched venous blood samples. The whole-blood Alere Q NAT POC assay produced results with a bias of 0.8593 log copy/ml compared to the laboratory-based plasma assay. However, at above 10,000 copies/ml, the bias was 0.07 log copy/ml. Using the WHO-recommended threshold to determine ART failure of 1,000 copies/ml, the sensitivity and specificity of the whole-blood Alere Q NAT POC assay were 96.83% and 47.80%, respectively. A cutoff of 10,000 copies/ml of whole blood with the Alere Q NAT POC assay appears to be a better predictor of ART failure threshold (1,000 copies/ml of plasma), with a sensitivity of 84.0% and specificity of 90.3%. The precision of the whole-blood Alere Q NAT POC assay was comparable to that observed with the laboratory technology (5.4% versus 7.5%) between detectable paired samples. HIV POC viral load testing is feasible at the primary health care level. Further research on the value of whole-blood viral load to monitor antiretroviral therapy is warranted.


Assuntos
Infecções por HIV/virologia , Sistemas Automatizados de Assistência Junto ao Leito , Atenção Primária à Saúde/métodos , RNA Viral/sangue , Carga Viral/métodos , Adolescente , Adulto , Idoso , Criança , Estudos Transversais , Monitoramento de Medicamentos/métodos , Feminino , Alemanha , Infecções por HIV/tratamento farmacológico , Humanos , Masculino , Pessoa de Meia-Idade , Moçambique , Sensibilidade e Especificidade , Adulto Jovem
4.
J Infect Dis ; 205 Suppl 2: S169-80, 2012 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-22457286

RESUMO

Stakeholders agree that supporting high-quality diagnostics is essential if we are to continue to make strides in the fight against human immunodeficiency virus (HIV) and tuberculosis. Despite the need to strengthen existing laboratory infrastructure, which includes expanding and developing new laboratories, there are clear diagnostic needs where conventional laboratory support is insufficient. Regarding HIV, rapid point-of-care (POC) testing for initial HIV diagnosis has been successful, but several needs remain. For tuberculosis, several new diagnostic tests have recently been endorsed by the World Health Organization, but a POC test remains elusive. Human immunodeficiency virus and tuberculosis are coendemic in many high prevalence locations, making parallel diagnosis of these conditions an important consideration. Despite its clear advantages, POC testing has important limitations, and laboratory-based testing will continue to be an important component of future diagnostic networks. Ideally, a strategic deployment plan should be used to define where and how POC technologies can be most efficiently and cost effectively integrated into diagnostic algorithms and existing test networks prior to widespread scale-up. In this fashion, the global community can best harness the tremendous capacity of novel diagnostics in fighting these 2 scourges.


Assuntos
Técnicas Bacteriológicas/métodos , Infecções por HIV/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito/economia , Tuberculose/diagnóstico , Virologia/métodos , Técnicas Bacteriológicas/economia , Humanos , Laboratórios , Garantia da Qualidade dos Cuidados de Saúde/economia , Garantia da Qualidade dos Cuidados de Saúde/métodos , Virologia/economia
5.
Lancet ; 378(9802): 1572-9, 2011 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-21951656

RESUMO

BACKGROUND: Loss to follow-up of HIV-positive patients before initiation of antiretroviral therapy can exceed 50% in low-income settings and is a challenge to the scale-up of treatment. We implemented point-of-care counting of CD4 cells in Mozambique and assessed the effect on loss to follow-up before immunological staging and treatment initiation. METHODS: In this observational cohort study, data for enrolment into HIV management and initiation of antiretroviral therapy were extracted retrospectively from patients' records at four primary health clinics providing HIV treatment and point-of-care CD4 services. Loss to follow-up and the duration of each preparatory step before treatment initiation were measured and compared with baseline data from before the introduction of point-of-care CD4 testing. FINDINGS: After the introduction of point-of-care CD4 the proportion of patients lost to follow-up before completion of CD4 staging dropped from 57% (278 of 492) to 21% (92 of 437) (adjusted odds ratio [OR] 0·2, 95% CI 0·15-0·27). Total loss to follow-up before initiation of antiretroviral treatment fell from 64% (314 of 492) to 33% (142 of 437) (OR 0·27, 95% CI 0·21-0·36) and the proportion of enrolled patients initiating antiretroviral therapy increased from 12% (57 of 492) to 22% (94 of 437) (OR 2·05, 95% CI 1·42-2·96). The median time from enrolment to antiretroviral therapy initiation reduced from 48 days to 20 days (p<0·0001), primarily because of a reduction in the median time taken to complete CD4 staging, which decreased from 32 days to 3 days (p<0·0001). Loss to follow-up between staging and antiretroviral therapy initiation did not change significantly (OR 0·84, 95% CI 0·49-1·45). INTERPRETATION: Point-of-care CD4 testing enabled clinics to stage patients rapidly on-site after enrolment, which reduced opportunities for pretreatment loss to follow-up. As a result, more patients were identified as eligible for and initiated antiretroviral treatment. Point-of-care testing might therefore be an effective intervention to reduce pretreatment loss to follow-up. FUNDING: Absolute Return for Kids and UNITAID.


Assuntos
Assistência Ambulatorial/métodos , Terapia Antirretroviral de Alta Atividade/métodos , Infecções por HIV/tratamento farmacológico , Sistemas Automatizados de Assistência Junto ao Leito , Adolescente , Adulto , Fatores Etários , Atitude Frente a Saúde , Contagem de Linfócito CD4 , Criança , Pré-Escolar , Estudos de Coortes , Intervalos de Confiança , Países em Desenvolvimento , Feminino , Seguimentos , Infecções por HIV/imunologia , Humanos , Lactente , Masculino , Moçambique , Razão de Chances , Cooperação do Paciente , Estudos Retrospectivos , Medição de Risco , Fatores Sexuais , Fatores Socioeconômicos , Resultado do Tratamento , Adulto Jovem
7.
PLoS One ; 14(7): e0219021, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31276477

RESUMO

BACKGROUND: Since 2010, point-of-care (POC) CD4 testing platforms have been introduced in both urban and rural settings to expand access to testing by bringing diagnostic services closer to patients. We conducted an analysis of routinely collected CD4 testing data to determine the invalid result rates associated with POC CD4 testing. METHODS: We analyzed 981,152 CD4 testing records collected from Alere Pima Analyzers between January 2011 and December 2016 across five countries in sub-Saharan Africa. Routinely collected data and programmatic records were used to determine the rate of invalid test results per month, by facility type, and by operator based on cumulative usage during the study period. In addition, frequency of invalid test types and utilization of control beads were assessed. RESULTS: Across the five countries, 75,530 invalid messages were returned, resulting in an overall invalid result rate of 7.7%. The invalid result rate by country ranged from 6.6% to 11.2%. Invalid result rates were consistent across facility types. Invalid result rates were inversely correlated with operator usage: low volume operators (<50 tests over study period) experienced an invalid result rate of 10.2%, while high volume operators (>500 tests over study period) experienced an invalid result rate of 5.5%. Two invalid result types (exposure position control and reagent control) accounted for nearly 50% of invalid results. Routine data showed that control beads were run on 88.3% of days that the device was used. CONCLUSIONS: Our analysis found that the rate of invalid results was consistent across all types of health facilities, indicating that decentralization of POC CD4 testing to lower level health facilities did not exhibit high invalid result rates or increase cartridge wastage. Additionally, invalid result rates were inversely correlated to operator usage, with high-volume operators experiencing lower invalid result rates than low-volume operators. POC CD4 testing can, therefore, be performed in decentralized national testing programs; however, adequate training, quality assurance, routine monitoring, and ongoing mentorship should also be implemented for success.


Assuntos
Infecções por HIV/imunologia , Testes Imediatos , Tecnologia sem Fio/instrumentação , África Subsaariana , Contagem de Linfócito CD4 , Estudos Transversais , Humanos , Saúde Pública , Reprodutibilidade dos Testes , Estudos Retrospectivos , Serviços de Saúde Rural
9.
AIDS ; 32(11): 1453-1463, 2018 07 17.
Artigo em Inglês | MEDLINE | ID: mdl-29746301

RESUMO

OBJECTIVE: We measured the effect of point-of-care (POC) early infant HIV testing on antiretroviral therapy initiation rates and retention in care among infants in Mozambique. DESIGN: A cluster-randomized trial was conducted in 16 primary healthcare centres providing either on-site POC arm (n = 8) or referred laboratory [standard-of-care (SOC) arm; n = 8] infant HIV testing. METHODS: The primary outcomes were the proportion of HIV-positive infants initiating antiretroviral therapy within 60 days of sample collection, and the proportion of HIV-positive infants who initiated antiretroviral therapy that were retained in care at 90 days of follow-up. RESULTS: The proportion of HIV-positive infants initiating antiretroviral therapy within 60 days of sample collection was 89.7% (157 of 175) for the POC arm and 12.8% (13 of 102) for the SOC arm [relative risk (RR)(adj) 7.34; P < 0.001]. The proportion of HIV-positive infants who initiated antiretroviral therapy that were retained in care at 90 days of follow-up was 61.6% (101 of 164) for the POC arm and 42.9% (21 of 49) for the SOC arm [RR(adj) 1.40; P < 0.027]. The median time from sample collection to antiretroviral therapy initiation was less than 1 day (interquartile range: 0-1) for the POC arm and 127 days (44-154; P < 0.001) for the SOC arm. CONCLUSION: POC infant HIV testing enabled clinics to more rapidly diagnose and provide treatment to HIV-infected infants. This reduced opportunities for pretreatment loss to follow-up and enabled a larger proportion of infants to receive test results and initiate antiretroviral therapy. The benefits of faster HIV diagnosis and antiretroviral treatment may also improve early retention in care.


Assuntos
Antirretrovirais/uso terapêutico , Infecções por HIV/diagnóstico , Infecções por HIV/tratamento farmacológico , Adesão à Medicação/estatística & dados numéricos , Sistemas Automatizados de Assistência Junto ao Leito , Retenção nos Cuidados/estatística & dados numéricos , Diagnóstico Precoce , Feminino , Humanos , Lactente , Masculino , Moçambique , Estudos Prospectivos
10.
PLoS One ; 13(6): e0198344, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29912987

RESUMO

BACKGROUND: Failure to timely diagnose HIV in infants is a major barrier for scaling-up paediatric antiretroviral treatment (ART). WHO recommends birth testing for earlier diagnosis and to improve test coverage, but current diagnosis takes 2-3 weeks to complete, thereby limiting the ability of care givers to provide follow-on care, especially in low-resource settings. We evaluated the benefit of implementing rapid diagnosis of HIV at birth in primary health care maternity wards in Mozambique. METHODS AND FINDINGS: Infants born to HIV-infected mothers delivering consecutively at eight primary health care clinics were tested within 24 hours of delivery using on-site POC (Alere q HIV1/2 Detect) and standard laboratory (Roche COBAS AmpliPrep/TaqMan HIV-1 qualitative assay v2.0) testing. Infants were also tested at 4-6 weeks of age with both assays. Of 2,350 HIV-exposed infants enrolled in this implementation research study, 33 tested HIV-positive at birth on both assays. Sensitivity and specificity of POC testing compared with laboratory testing at birth were 100% (95% CI 89·4-100·0) and 100% (95% CI 99·8-100·0), respectively. At 4-6 weeks of age, 61 infants were identified as HIV-positive; of these 29 (47·5%) had a positive test at birth. Testing at both birth and 4-6 weeks identified 71 HIV-positive infants compared with 61 infants by testing at 4-6 weeks alone, a 16% increase. Two infants tested positive at birth but tested HIV-negative during follow-up. CONCLUSIONS: Adding POC birth testing to the 4-6 week screen may increase access to HIV diagnosis and expedite ART initiation in primary health care settings within low resource settings. Guidance on appropriate confirmatory HIV testing algorithms for birth testing is needed.


Assuntos
Fármacos Anti-HIV/uso terapêutico , Infecções por HIV/diagnóstico , Infecções por HIV/tratamento farmacológico , HIV-1/genética , Estudos de Coortes , Diagnóstico Precoce , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Moçambique , Testes Imediatos , Guias de Prática Clínica como Assunto , Atenção Primária à Saúde , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade , Tempo para o Tratamento
11.
PLoS One ; 12(1): e0169497, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28060886

RESUMO

The long delay in returning test results during early infant diagnosis of HIV (EID) often causes loss-to-follow-up prior to antiretroviral treatment (ART) initiation in resource-limited settings. A point-of-care (POC) test may help overcome these challenges. We evaluated the performance of the LYNX p24 Antigen POC test in Mozambique. 879 HIV-exposed infants under 18 months of age were enrolled consecutively at three primary healthcare clinics (PHC). Lancet heel-drawn blood was tested on-site by nurses using a prototype POC test for HIV Gag p24 antigen detection. Results of POC testing were compared to laboratory-based nucleic acid testing on dried blood spots. A comparison of the effect of sensitivity and timely test results return on successful diagnosis by POC and laboratory-based platforms was also calculated. The sensitivity and specificity of the LYNX p24 Ag test were 71.9%; (95% confidence interval [CI]: 58.5-83.0%) and 99.6% (95% CI: 98.9-99.9%), respectively. The predictive value of positive and negative tests were 93.2% (95% CI: 81.3-98.6%) and 97.9% (95% CI: 96.8-98.8%), respectively. Overall agreement was high (Cohen Kappa = 0.80; 95% CI: 0.71-0.89). Despite its lower sensitivity, the POC test had the potential to provide test results to up to 81% more patients compared to the laboratory-based test. This prototype POC p24 assay was feasible for use in PHCs but demonstrated low sensitivity for HIV detection. POC EID technologies that perform below standard recommendations may still be valuable diagnostic tools in settings with inefficient EID networks.


Assuntos
Proteína do Núcleo p24 do HIV , Infecções por HIV/diagnóstico , HIV-1 , Testes Imediatos , Fármacos Anti-HIV/uso terapêutico , Pré-Escolar , Estudos Transversais , Diagnóstico Precoce , Feminino , Proteína do Núcleo p24 do HIV/imunologia , Infecções por HIV/tratamento farmacológico , Infecções por HIV/epidemiologia , Infecções por HIV/imunologia , HIV-1/imunologia , Humanos , Lactente , Recém-Nascido , Masculino , Moçambique/epidemiologia , Testes Imediatos/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Padrão de Cuidado , Fluxo de Trabalho
12.
Trends Parasitol ; 18(5): 214-8, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-11983602

RESUMO

Several wild animal species have been implicated as hosts of Ehrlichia ruminantium (formerly Cowdria ruminantium), the rickettsial agent causing heartwater, a fatal disease of domestic ruminants in sub-Saharan Africa and eastern Caribbean. However, evidence for infection in most wild species is inconclusive because of inadequate diagnostic techniques. Infection has been proven only in 12 African ruminants, three non-African ruminants and two African rodents. A subclinical carrier state occurs in eight of the African ruminant species. Further studies on E. ruminantium infection in wild animal species are needed in order to determine the host range of this pathogen accurately. The host range of Ehrlichia ruminantium in wildlife is reviewed here and the role played by these species in the epidemiology and spread of heartwater is discussed.


Assuntos
Animais Selvagens , Portador Sadio/veterinária , Hidropericárdio/epidemiologia , Ruminantes , África/epidemiologia , Animais , Vetores Aracnídeos , Portador Sadio/epidemiologia , Portador Sadio/transmissão , Reservatórios de Doenças/veterinária , Suscetibilidade a Doenças/veterinária , Ehrlichia ruminantium , Hidropericárdio/microbiologia , Hidropericárdio/transmissão , Interações Hospedeiro-Parasita , Roedores
13.
Ann N Y Acad Sci ; 969: 269-74, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12381604

RESUMO

Opportunities to introduce heartwater onto the American mainland through animal movements include importation from Africa of tick-infested reptiles and of subclinically infected wild ungulates and importation of livestock from islands in the Caribbean infested with Amblyomma variegatum ticks. Measures to control importation of heartwater vectors on reptiles include importation bans of infested species, treatment of imported reptiles, and eradication of established infestations on the American mainland. Measures to control importation of infected wildlife must focus on improved methods, such as the PCR assay, of screening animals to prevent the entry of carriers of Cowdria ruminantium. Measures to control importation of infected animals from the Caribbean must be based on knowledge of the islands that are infected with C. ruminantium so that the risk of dissemination of heartwater can be established.


Assuntos
Vetores Aracnídeos/microbiologia , Ehrlichia ruminantium/isolamento & purificação , Hidropericárdio/transmissão , Ixodidae/microbiologia , Répteis/parasitologia , Infestações por Carrapato/veterinária , África/epidemiologia , Animais , Região do Caribe/epidemiologia , Hidropericárdio/epidemiologia , Hidropericárdio/prevenção & controle , Fatores de Risco , Infestações por Carrapato/epidemiologia , Infestações por Carrapato/prevenção & controle , Meios de Transporte , Estados Unidos/epidemiologia
14.
Ann N Y Acad Sci ; 969: 294-6, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12381608

RESUMO

Studies using the African tortoise tick (Amblyomma marmoreum) and leopard tortoises (Geochelone pardalis) demonstrated that cyfluthrin and permethrin were safe and efficacious acaricides for control of Amblyomma ticks on tortoises. A protocol was developed that successfully eradicated an A. sparsum infestation from a tortoise breeding facility in Florida. It involved treatment of all tortoises with a permethrin formulation, followed by treatment of the premises with a cyfluthrin formulation. Sentinel tortoises were later placed on the treated premises to establish successful tick eradication.


Assuntos
Vetores Aracnídeos , Hidropericárdio/prevenção & controle , Inseticidas/uso terapêutico , Ixodidae , Infestações por Carrapato/veterinária , Tartarugas/parasitologia , Animais , Vetores Aracnídeos/microbiologia , Ehrlichia ruminantium , Feminino , Florida , Hidropericárdio/transmissão , Ixodidae/microbiologia , Masculino , Nitrilas , Permetrina/uso terapêutico , Piretrinas/uso terapêutico , Controle de Ácaros e Carrapatos , Infestações por Carrapato/tratamento farmacológico , Infestações por Carrapato/parasitologia , Resultado do Tratamento
15.
J Zoo Wildl Med ; 33(1): 52-7, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12216793

RESUMO

Nine acaricides (amitraz, carbaryl, chlorpyrifos, cyfluthrin, fipronil, lindane, permethrin, phenothrin, and pyrethrins) were studied for their efficacy in killing the African tortoise tick (Amblyomma marmoreum). Only four of the acaricides (chlorpyrifos, cyfluthrin, lindane, and permethrin) produced 100% mortality within 24 hr of application, and only two (cyfluthrin and permethrin) continued to cause 100% mortality when diluted to as low as 1:10,000. Five of the acaricides (amitraz, carbaryl, chlorpyrifos, cyfluthrin, and permethrin) were studied for toxicity to the leopard tortoise (Geochelone pardalis), the most common host of A. marmoreum. The results indicate that cyfluthrin and permethrin, which were herein found to be the two most effective acaricides for control of A. marmoreum, are also the safest acaricides for use on leopard tortoises.


Assuntos
Inseticidas/normas , Ixodidae , Infestações por Carrapato/veterinária , Tartarugas/parasitologia , Animais , Feminino , Inseticidas/administração & dosagem , Inseticidas/efeitos adversos , Masculino , Nitrilas , Permetrina/administração & dosagem , Permetrina/efeitos adversos , Permetrina/normas , Piretrinas/administração & dosagem , Piretrinas/efeitos adversos , Piretrinas/normas , Infestações por Carrapato/prevenção & controle
16.
J Acquir Immune Defic Syndr ; 67(1): e1-4, 2014 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-24933096

RESUMO

OBJECTIVE: To evaluate the accuracy of a point-of-care (POC) nucleic acid-based test (NAT) for early infant HIV diagnosis (EID) in primary health clinics in Mozambique. METHODS: POC and laboratory NAT EID tests were conducted on matched blood samples collected from 827 HIV-exposed infants younger than 18 months who were enrolled consecutively at 4 periurban primary health clinics and the central hospital in Maputo. Lancet heel draw blood collected by nurses was tested on site for HIV-1/-2 RNA on the Alere HIV NAT POC device and also used to create dried blood spots for later laboratory EID testing on the Roche Cobas Taqman/Ampliprep instrument. Results were used to determine the sensitivity, specificity, and agreement between the POC and laboratory NAT EID tests. RESULTS: The sensitivity and specificity of POC NAT EID testing were 98·5% (95% confidence interval (CI): 91.7 to 99.9, n = 65) and 99·9% (95% CI: 99.3 to 100, n = 762), respectively, compared with laboratory EID tests. Overall agreement was high (Cohen kappa = 0·981; 95% CI: 0.96 to 1.00). Positive (98·5%; 95% CI: 96·3 to 100) and negative 99.9% (95% CI: 99.7 to 100) test agreement was also high. CONCLUSIONS: Primary health care nurses accurately performed POC NAT EID testing within primary health care clinics. On-site nucleic acid-based EID testing is technically feasible in clinic settings and could be used in efforts to improve access to pediatric HIV antiretroviral treatment.


Assuntos
Infecções por HIV/diagnóstico , Infecções por HIV/virologia , HIV-1/isolamento & purificação , Instituições de Assistência Ambulatorial , Estudos Transversais , Método Duplo-Cego , Diagnóstico Precoce , Infecções por HIV/sangue , HIV-1/genética , Humanos , Lactente , Moçambique , Reação em Cadeia da Polimerase , Estudos Prospectivos , RNA Viral/química , RNA Viral/genética , Sensibilidade e Especificidade
17.
PLoS One ; 7(10): e47459, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23118871

RESUMO

The expansion of HIV antiretroviral therapy into decentralized rural settings will increasingly require simple point-of-care (POC) diagnostic tests that can be used without laboratory infrastructure and technical skills. New POC test devices are becoming available but decisions around which technologies to deploy may be biased without systematic assessment of their suitability for decentralized healthcare settings. To address this, we developed a standardized, quantitative scorecard tool to objectively evaluate the operational characteristics of POC diagnostic devices. The tool scores devices on a scale of 1-5 across 30 weighted characteristics such as ease of use, quality control, electrical requirements, shelf life, portability, cost and service, and provides a cumulative score that ranks products against a set of ideal POC characteristics. The scorecard was tested on 19 devices for POC CD4 T-lymphocyte cell counting, clinical chemistry or hematology testing. Single and multi-parameter devices were assessed in each of test categories. The scores across all devices ranged from 2.78 to 4.40 out of 5. The tool effectively ranked devices within each category (p<0.01) except the CD4 and multi-parameter hematology products. The tool also enabled comparison of different characteristics between products. Agreement across the four scorers for each product was high (intra-class correlation >0.80; p<0.001). Use of this tool enables the systematic evaluation of diagnostic tests to facilitate product selection and investment in appropriate technology. It is particularly relevant for countries and testing programs considering the adoption of new POC diagnostic tests.


Assuntos
Contagem de Linfócito CD4/instrumentação , Testes Diagnósticos de Rotina/métodos , Infecções por HIV/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , Contagem de Linfócito CD4/normas , Linfócitos T CD4-Positivos/citologia , Testes Diagnósticos de Rotina/normas , HIV/isolamento & purificação , Infecções por HIV/terapia , Humanos , Controle de Qualidade
18.
PLoS One ; 7(8): e41166, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22912668

RESUMO

INTRODUCTION: Point-of-care (POC) CD4 testing can improve access to treatment by enabling decentralization and reducing patient loss-to-follow-up. As new POC CD4 technologies become available, their performance should be assessed before widespread deployment. This study reports the findings of five independent evaluations of the PointCare NOW CD4 system. MATERIALS/METHODS: Evaluations were conducted in Southern Africa (Mozambique, South Africa) and North America (Canada, USA). 492 blood samples (55 from HIV-negative blood donors and 437 from HIV-infected patients, including 20 children aged between 12 and 59 months) were tested with both the PointCare NOW and reference flow cytometry instruments. Assessment of bias, precision and levels of clinical misclassification for absolute and percent CD4 count was conducted. RESULTS: PointCare NOW significantly overestimated CD4 absolute counts with a mean relative bias of +35.0%. Bias was greater in samples with CD4 counts below ≤ 350 cells/µl (+51.3%) than in the CD4 >350 cells/µl stratum (15.1%). Bias in CD4% had a similar trend with an overall relative mean bias of +25.6% and a larger bias for low CD4 stratum (+40.2%) than the higher CD4 stratum (+5.8%). Relative bias for CD4% in children was -6.8%. In terms of repeatability, PointCare NOW had a coefficient of variation of 11%. Using a threshold of 350 cells/µl, only 47% of patients who qualified for antiretroviral therapy with reference CD4 testing, would have been eligible for treatment with PointCare NOW test results. This was 39% using a 200 cells/µl threshold. Agreement with infant samples was higher, with 90% qualifying at a 25% eligibility threshold. CONCLUSION: The performance of the PointCare NOW instrument for absolute and percent CD4 enumeration was inadequate for HIV clinical management in adults. In children, the small sample size was not large enough to draw a conclusion. This study also highlights the importance of independent evaluation of new diagnostic technology platforms before deployment.


Assuntos
Contagem de Linfócito CD4/métodos , Infecções por HIV/imunologia , Sistemas Automatizados de Assistência Junto ao Leito , Adulto , Fármacos Anti-HIV/uso terapêutico , Contagem de Linfócito CD4/normas , Pré-Escolar , Definição da Elegibilidade , Infecções por HIV/tratamento farmacológico , Humanos , Lactente , Sistemas Automatizados de Assistência Junto ao Leito/normas , Controle de Qualidade , Sensibilidade e Especificidade
19.
AIDS ; 25(6): 807-12, 2011 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-21378535

RESUMO

OBJECTIVE: To evaluate the accuracy of point-of-care tests (POCTs) for CD4 cell, clinical chemistry and hemoglobin in primary healthcare clinics in Mozambique. DESIGN AND METHODS: POCT and laboratory-based assays were conducted on adult HIV-positive patients enrolled consecutively at primary healthcare clinics in Mozambique. Patients were tested on-site with POCT CD4 (Pima), clinical chemistry (Reflotron) and hemoglobin (HemoCue) devices using finger prick blood. Results obtained on paired blood samples were used for agreement analysis (bias and limits of agreement). Repeatability analysis was also performed for POCT CD4 cell counting. RESULTS: Primary health nurses operating the Pima, Reflotron and HemoCue POCT devices produced results with low levels of bias for CD4(+) T-cell counts (-52.8 cells/µl), alanine aminotransferase (-0.2 U/l), aspartate aminotransferase (-4.0 U/l) and hemoglobin (0.95 g/dl). CD4(+) T-cell counts in paired specimens of finger prick and venous blood tested on the POCT CD4 device were in close agreement (bias -9 cells/µl, coefficient of variation 10.6%). The repeatability of POCT CD4 cell counting was similar to that observed with laboratory instruments (bias -6.2 cells/µl, coefficient of variation 10.7% vs. bias -5.7 cells/µl, coefficient of variation 7.5%). CONCLUSION: Primary health clinic nurses generated accurate results for CD4(+) T-cell counts, liver enzymes and hemoglobin using simple POC devices on finger prick samples at decentralized antiretroviral therapy (ART) clinics. POC diagnostics to monitor ART at primary healthcare level is technically feasible and should be utilized in efforts to decentralize HIV care and treatment.


Assuntos
Terapia Antirretroviral de Alta Atividade/efeitos adversos , Contagem de Linfócito CD4 , Infecções por HIV/sangue , Atenção Primária à Saúde/normas , Adolescente , Adulto , Idoso , Monitoramento de Medicamentos , Feminino , Infecções por HIV/tratamento farmacológico , Humanos , Masculino , Pessoa de Meia-Idade , Moçambique , Sistemas Automatizados de Assistência Junto ao Leito , Adulto Jovem
20.
Am J Clin Pathol ; 134(4): 550-5, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20855635

RESUMO

Accreditation is emerging as a preferred framework for building quality medical laboratory systems in resource-limited settings. Despite the low numbers of laboratories accredited to date, accreditation has the potential to improve the quality of health care for patients through the reduction of testing errors and attendant decreases in inappropriate treatment. Accredited laboratories can become more accountable and less dependent on external support. Efforts made to achieve accreditation may also lead to improvements in the management of laboratory networks by focusing attention on areas of greatest need and accelerating improvement in areas such as supply chain, training, and instrument maintenance. Laboratory accreditation may also have a positive influence on performance in other areas of health care systems by allowing laboratories to demonstrate high standards of service delivery. Accreditation may, thus, provide an effective mechanism for health system improvement yielding long-term benefits in the quality, cost-effectiveness, and sustainability of public health programs. Further studies are needed to strengthen the evidence on the benefits of accreditation and to justify the resources needed to implement accreditation programs aimed at improving the performance of laboratory systems.


Assuntos
Acreditação/normas , Laboratórios/normas , Assistência ao Paciente/normas , Contagem de Linfócito CD4 , Técnicas de Laboratório Clínico/normas , Erros de Diagnóstico/prevenção & controle , Infecções por HIV/diagnóstico , Infecções por HIV/terapia , Humanos , Laboratórios/organização & administração , Garantia da Qualidade dos Cuidados de Saúde/normas , Controle de Qualidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA