Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Opt Express ; 31(8): 13226-13242, 2023 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-37157464

RESUMO

Non-planar image-rotating OPO ring resonators necessitate polarisation compensation in contrast to their planar counterparts. This is essential for maintaining phase matching conditions for non-linear optical conversion in the resonator during each cavity round trip. In this study, we examine the polarisation compensation and its impact on the performance of two types of non-planar resonators: RISTRA with a π2 image rotation and FIRE with a fractional image rotation (π2 fraction). The RISTRA is insensitive to mirror phase shifts, while the FIRE has a more complex dependence of polarisation rotation on mirror phase shifts. There has been debate over whether a single birefringent element can provide adequate polarisation compensation for non-planar resonators beyond RISTRA-type. Our results show that under certain experimentally feasible conditions, even FIRE resonators can achieve adequate polarisation compensation with a single half-wave plate. We validate our theoretical analysis through numerical simulations and experimental studies of OPO output beam polarisation using ZnGeP2 non-linear crystals.

2.
Opt Express ; 29(2): 2577-2586, 2021 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-33726450

RESUMO

We report on changes of beam quality with rising pump pulse energy and repetition rate in a high-power mid-infrared ZnGeP2 (ZGP) OPO in a non-planar cavity. The ZGP OPO generates 25 W in 3 - 5 µm pumped by a 10 kHz Q-switched Ho:LLF MOPA system at 2 µm. The beam quality factor increases from nearly diffraction-limited at OPO threshold to a M2 = 1.8 at maximum pump power. The degradation can be attributed to thermal lensing and gain guiding effects in the nonlinear crystal. To discriminate between those effects, we monitored the beam quality as a function of the repetition rate at the highest pump pulse energy using a Pockels cell as a pulse picker. Therefore, the heat load inducing thermal lensing increases linearly, whereas gain guiding remains nearly unaffected. M2 shows a minimum of 1.2 at 1 kHz, starting from 1.3 at 100 Hz and rising to 1.8 at 10 kHz. Those findings have been reproduced by numerical simulations. Further investigations show the transient evolution of beam quality, revealing the thermal lens build-up process to the steady-state.

3.
Opt Express ; 29(14): 21727-21737, 2021 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-34265953

RESUMO

We compare the performance of ns-pulsed mid-infrared optical parametric oscillators (OPOs) based on ZGP crystals in a simple linear cavity and two non-planar image-rotating resonators. Our 2 µm pump source is a 68 W 10 kHz diffraction limited Ho:LLF MOPA system. In a linear cavity, it allows us to generate up to 38 W of the total average power with M2<2.2 from the ZGP OPO in the 3-5 µm range. Beam quality and stability are significantly improved in both types of non-planar ring resonators (M2<1.8 in RISTRA and M2<1.4 in FIRE), while the total average power is above 21 W. Factors influencing the beam quality such as average power and pump repetition rate are studied in detail.

4.
Sensors (Basel) ; 21(19)2021 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-34640768

RESUMO

This paper presents a camera-based prototype sensor for detecting fatigue and drowsiness in drivers, which are common causes of road accidents. The evaluation of the detector operation involved eight professional truck drivers, who drove the truck simulator twice-i.e., when they were rested and drowsy. The Fatigue Symptoms Scales (FSS) questionnaire was used to assess subjectively perceived levels of fatigue, whereas the percentage of eye closure time (PERCLOS), eye closure duration (ECD), and frequency of eye closure (FEC) were selected as eye closure-associated fatigue indicators, determined from the images of drivers' faces captured by the sensor. Three alternative models for subjective fatigue were used to analyse the relationship between the raw score of the FSS questionnaire, and the eye closure-associated indicators were estimated. The results revealed that, in relation to the subjective assessment of fatigue, PERCLOS is a significant predictor of the changes observed in individual subjects during the performance of tasks, while ECD reflects the individual differences in subjective fatigue occurred both between drivers and in individual drivers between the 'rested' and 'drowsy' experimental conditions well. No relationship between the FEC index and the FSS state scale was found.


Assuntos
Condução de Veículo , Fadiga/diagnóstico , Humanos , Veículos Automotores , Descanso , Vigília
5.
Opt Express ; 25(4): 3165-3179, 2017 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-28241534

RESUMO

We present a two-species laser cooling apparatus capable of simultaneously collecting Rb and Hg atomic gases into a magneto-optical trap (MOT). The atomic sources, laser system, and vacuum set-up are described. While there is a loss of Rb atoms in the MOT due to photoionization by the Hg cooling laser, we show that it does not prevent simultaneous trapping of Rb and Hg. We also demonstrate interspecies collision-induced losses in the 87Rb-202Hg system.

6.
Sci Adv ; 4(3): eaao4453, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29740598

RESUMO

Forces drive all physical interactions. High-sensitivity measurement of the effect of forces enables the quantitative investigation of physical phenomena. Laser-cooled trapped atomic ions are a well-controlled quantum system whose low mass, strong Coulomb interaction, and readily detectable fluorescence signal make them a favorable platform for precision metrology. We demonstrate a three-dimensional sub-attonewton sensitivity force sensor based on a super-resolution imaging of a single trapped ion. The force is detected by measuring the ion's displacement in three dimensions with nanometer precision. Observed sensitivities were 372 ± 9, 347 ± 18, and 808 ± 51 zN/[Formula: see text], corresponding to 24×, 87×, and 21× above the quantum limit. We verified this technique by measuring a 95-zN light pressure force, an important systematic effect in optically based sensors.

7.
Aerosp Med Hum Perform ; 86(6): 518-23, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26099122

RESUMO

INTRODUCTION: The main aim of this study was to differentiate the magnitude of a pilot's heart rate variability (HRV) when performing assisted and unassisted flights, as well as simple and complex flight tasks. METHODS: Cardiac monitoring in flights was carried out using a compact, mobile ECG recorder. A frequency analysis of the heart rate (HR) signal was performed to determine the ratio of low-frequency spectral power (LF) to high-frequency spectral power (HF). RESULTS: The LF/HF ratio observed in the zone (M=1.047, SD=0.059) was significantly different than the LF/HF calculated preflight (M=0.877, SD=0.043) and postflight (M=0.793, SD=0.037). There was no main effect of the flight type (unassisted zone flight vs. zone flight with an instructor) on the LF/HF parameter. However, greater psychophysiological load of a pilot was observed in the training zone flights when compared to simple circle flights (main effect of the flight type). CONCLUSIONS: As the LF/HF ratio turned out to be significantly higher in the zone than pre- and postflight, this parameter can be useful for predicting the risk of excessive stress and arousal of pilots during flights. Based on the LF/HF ratio we can also estimate difficulty level of flight tasks, because our research has shown higher values of this parameter in the training zone flights than in simple circle flights.


Assuntos
Medicina Aeroespacial , Aeronaves , Frequência Cardíaca/fisiologia , Estresse Fisiológico/fisiologia , Estresse Psicológico/fisiopatologia , Adulto , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Modelos Estatísticos , Processamento de Sinais Assistido por Computador , Análise e Desempenho de Tarefas , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA