Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Magn Reson Med ; 85(4): 1909-1923, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33165952

RESUMO

PURPOSE: To explore the impact of temporal motion-induced coil sensitivity changes on CEST-MRI at 7T and its correction using interleaved volumetric EPI navigators, which are applied for real-time motion correction. METHODS: Five healthy volunteers were scanned via CEST. A 4-fold correction pipeline allowed the mitigation of (1) motion, (2) motion-induced coil sensitivity variations, ΔB1- , (3) motion-induced static magnetic field inhomogeneities, ΔB0 , and (4) spatially varying transmit RF field fluctuations, ΔB1+ . Four CEST measurements were performed per session. For the first 2, motion correction was turned OFF and then ON in absence of voluntary motion, whereas in the other 2 controlled head rotations were performed. During post-processing ΔB1- was removed additionally for the motion-corrected cases, resulting in a total of 6 scenarios to be compared. In all cases, retrospective ∆B0 and - ΔB1+ corrections were performed to compute artifact-free magnetization transfer ratio maps with asymmetric analysis (MTRasym ). RESULTS: Dynamic ΔB1- correction successfully mitigated signal deviations caused by head motion. In 2 frontal lobe regions of volunteer 4, induced relative signal errors of 10.9% and 3.9% were reduced to 1.1% and 1.0% after correction. In the right frontal lobe, the motion-corrected MTRasym contrast deviated 0.92%, 1.21%, and 2.97% relative to the static case for Δω = 1, 2, 3 ± 0.25 ppm. The additional application of ΔB1- correction reduced these deviations to 0.10%, 0.14%, and 0.42%. The fully corrected MTRasym values were highly consistent between measurements with and without intended head rotations. CONCLUSION: Temporal ΔB1- cause significant CEST quantification bias. The presented correction pipeline including the proposed retrospective ΔB1- correction significantly reduced motion-related artifacts on CEST-MRI.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Humanos , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Estudos Retrospectivos
2.
Magn Reson Med ; 82(2): 633-646, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30924210

RESUMO

PURPOSE: To assess the performance, in the presence of scanner instabilities, of three dynamic correction methods which integrate ∆B0 mapping into the chemical exchange saturation transfer (CEST) measurement and three established static ∆B0 -correction approaches. METHODS: A homogeneous phantom and five healthy volunteers were scanned with a CEST sequence at 7 T. The in vivo measurements were performed twice: first with unaltered system frequency and again applying frequency shifts during the CEST acquisition. In all cases, retrospective voxel-wise ∆B0 -correction was performed using one intrinsic and two extrinsic [prescans with dual-echo gradient-echo and water saturation shift referencing (WASSR)] static approaches. These were compared with two intrinsic [using phase data directly generated by single-echo or double-echo GRE (gradient-echo) CEST readout (CEST-GRE-2TE)] and one extrinsic [phase from interleaved dual-echo EPI (echo planar imaging) navigator (NAV-EPI-2TE)] dynamic ∆B0 -correction approaches [allowing correction of each Z-spectral point before magnetization transfer ratio asymmetry (MTRasym) analysis]. RESULTS: All three dynamic methods successfully mapped the induced drift. The intrinsic approaches were affected by the CEST labeling near water (∆ω < |0.3| ppm). The MTRasym contrast was distorted by the frequency drift in the brain by up to 0.21%/Hz when static ∆B0 -corrections were applied, whereas the dynamic ∆B0 corrections reduced this to <0.01%/Hz without the need of external scans. The CEST-GRE-2TE and NAV-EPI-2TE resulted in highly consistent MTRasym values with/without drift for all subjects. CONCLUSION: Reliable correction of scanner instabilities is essential to establish clinical CEST MRI. The three dynamic approaches presented improved the ∆B0 -correction performance significantly in the presence of frequency drift compared to established static methods. Among them, the self-corrected CEST-GRE-2TE was the most accurate and straightforward to implement.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Encéfalo/diagnóstico por imagem , Imagem Ecoplanar , Feminino , Humanos , Masculino , Imagens de Fantasmas
3.
Magn Reson Imaging ; 59: 77-87, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30880110

RESUMO

OBJECTIVES: To investigate the feasibility of chemical exchange saturation transfer (CEST) MRI in patients with breast carcinomas and possible correlations between magnetization transfer asymmetry (MTRasym) values and histological features, such as tumor grade and the Ki-67 proliferation index. MATERIALS AND METHODS: Nine healthy subjects and 18 female patients were enrolled for this study. The imaging protocol for the patients consisted of diffusion-weighted imaging (DWI), CEST imaging, and T1-weighted, contrast-enhanced (CE)-MRI. CEST was performed using a 3D gradient echo (GRE) sequence, employing eight pre-saturation pulses of a duration of 50 ms and a duty cycle (DC) of 80%, with a mean amplitude of the saturation pulse train of 1 µT. The Z-spectrum was plotted and MTRasym values calculated for the frequency of the maximum of MTRasym curve, were correlated with the Ki-67 proliferation index and apparent diffusion coefficient (ADC). Patient data were statistically assessed using the Games-Howell post-hoc and Pearson's correlation test. RESULTS: Different tumor types had asymmetry peaks at different positions of Z-spectrum. MTRasym (mean ±â€¯SD) (%) calculated for G1 (3.0 ±â€¯0.3; range: 2.70-3.50) was not significantly lower than for G2 (4.50 ±â€¯1.30; range: 3.20-6.50; p = 0.066). In contrast, the increase in MTRasym between G1 and G3 (6.40 ±â€¯1.70; range: 4.80-9.80) lesions was significant (p = 0.007). No significant difference was observed between G2 and G3 with regard to MTRasym (p = 0.089). There was a strong positive correlation between the MTRasym, and Ki-67 proliferation index (r = 0.890; p = 0.001), while there was a moderate negative correlation between MTRasym and ADC values (r = -0.506; p = 0.027). CONCLUSIONS: Calculated MTRasym demonstrates a strong positive correlation with tumor proliferation and has the potential to become a valuable biomarker for breast tumor characterization.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Imageamento por Ressonância Magnética , Gradação de Tumores , Adulto , Biomarcadores , Neoplasias da Mama/patologia , Proliferação de Células , Feminino , Humanos , Antígeno Ki-67/metabolismo , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA