Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Small ; 20(40): e2402235, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38845530

RESUMO

The field of second near-infrared (NIR-II) surface-enhanced Raman scattering (SERS) nanoprobes has made commendable progress in biomedicine. This article reviews recent advances and future development of NIR-II SERS nanoprobes. It introduces the fundamental principles of SERS nanoprobes and highlights key advances in the NIR-II window, including reduced tissue attenuation, deep penetration, maximized allowable exposure, and improved photostability. The discussion of future directions includes the refinement of nanoprobe substrates, emphasizing the tailoring of optical properties of metallic SERS-active nanoprobes, and exploring non-metallic alternatives. The intricacies of designing Raman reporters for the NIR-II resonance and the potential of these reporters to advance the field are also discussed. The integration of artificial intelligence (AI) into nanoprobe design represents a cutting-edge approach to overcome current challenges. This article also examines the emergence of deep Raman techniques for through-tissue SERS detection, toward NIR-II SERS tomography. It acknowledges instrumental advancements like improved charge-coupled device sensitivity and accelerated imaging speeds. The article concludes by addressing the critical aspects of biosafety, ease of functionalization, compatibility, and the path to clinical translation. With a comprehensive overview of current achievements and future prospects, this review aims to illuminate the path for NIR-II SERS nanoprobes to innovate diagnostic and therapeutic approaches in biomedicine.


Assuntos
Análise Espectral Raman , Análise Espectral Raman/métodos , Humanos , Animais
2.
Chem Soc Rev ; 52(24): 8531-8579, 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-37882143

RESUMO

Human-infecting pathogens that transmit through the air pose a significant threat to public health. As a prominent instance, the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) that caused the COVID-19 pandemic has affected the world in an unprecedented manner over the past few years. Despite the dissipating pandemic gloom, the lessons we have learned in dealing with pathogen-laden aerosols should be thoroughly reviewed because the airborne transmission risk may have been grossly underestimated. From a bioanalytical chemistry perspective, on-site airborne pathogen detection can be an effective non-pharmaceutic intervention (NPI) strategy, with on-site airborne pathogen detection and early-stage infection risk evaluation reducing the spread of disease and enabling life-saving decisions to be made. In light of this, we summarize the recent advances in highly efficient pathogen-laden aerosol sampling approaches, bioanalytical sensing technologies, and the prospects for airborne pathogen exposure measurement and evidence-based transmission interventions. We also discuss open challenges facing general bioaerosols detection, such as handling complex aerosol samples, improving sensitivity for airborne pathogen quantification, and establishing a risk assessment system with high spatiotemporal resolution for mitigating airborne transmission risks. This review provides a multidisciplinary outlook for future opportunities to improve the on-site airborne pathogen detection techniques, thereby enhancing the preparedness for more on-site bioaerosols measurement scenarios, such as monitoring high-risk pathogens on airplanes, weaponized pathogen aerosols, influenza variants at the workplace, and pollutant correlated with sick building syndromes.


Assuntos
COVID-19 , Pandemias , Humanos , Pandemias/prevenção & controle , Aerossóis e Gotículas Respiratórios , COVID-19/diagnóstico , COVID-19/prevenção & controle , SARS-CoV-2
3.
Appl Microbiol Biotechnol ; 106(5-6): 2207-2218, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35218386

RESUMO

The pandemic of coronavirus disease 2019 (COVID-19) continues to threaten public health. For developing countries where vaccines are still in shortage, cheaper alternative molecular methods for SARS-CoV-2 identification can be crucial to prevent the next wave. Therefore, 14 primer sets recommended by the World Health Organization (WHO) was evaluated on testing both clinical patient and environmental samples with the gold standard diagnosis method, TaqMan-based RT-qPCR, and a cheaper alternative method, SYBR Green-based RT-qPCR. Using suitable primer sets, such as ORF1ab, 2019_nCoV_N1 and 2019_nCoV_N3, the performance of the SYBR Green approach was comparable or better than the TaqMan approach, even when considering the newly dominating or emerging variants, including Delta, Eta, Kappa, Lambda, Mu, and Omicron. ORF1ab and 2019_nCoV_N3 were the best combination for sensitive and reliable SARS-CoV-2 molecular diagnostics due to their high sensitivity, specificity, and broad accessibility. KEY POINTS: • With suitable primer sets, the SYBR Green method performs better than the TaqMan one. • With suitable primer sets, both methods should still detect the new variants well. • ORF1ab and 2019_nCoV_N3 were the best combination for SARS-CoV-2 detection.


Assuntos
COVID-19 , SARS-CoV-2 , Benzotiazóis , COVID-19/diagnóstico , Diaminas , Humanos , Quinolinas , RNA Viral/análise , Reação em Cadeia da Polimerase em Tempo Real/métodos , SARS-CoV-2/genética , Sensibilidade e Especificidade
4.
Anal Chem ; 93(17): 6784-6791, 2021 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-33877822

RESUMO

The implementation of colorimetric analysis within microfluidic environments engenders significant benefits with respect to reduced sample and reagent consumption, system miniaturization, and real-time measurement of flowing samples. That said, conventional approaches to colorimetric analysis within microfluidic channels are hampered by short optical pathlengths and single-channel configurations, which lead to poor detection sensitivities and low analytical throughputs. Although the use of multiplexed light source/photodetector modules allows for multichannel analysis, such configurations significantly increase both instrument complexity and cost. To address these issues, we present a four-channel colorimetric measurement scheme within an optical-switch-enabled microfluidic chip (OSEMC) fabricated by two-photon stereolithography. The integration of optical switches enables sequential signal readout from each detection channel, and thus, only a single light source and a photodetector are required for operation. Optical switches can be controlled in a bespoke manner by changing the medium in the switch channel between a "light-transmitting" fluid and a "light-blocking" fluid using pneumatic microvalves. Such optical switches are characterized by fast response times (approximately 200 ms), tunable switching frequencies (between 0.1 and 1.0 Hz studied), and excellent stability. Operational performance demonstrates both good sensitivity and reproducibility through the colorimetric analysis of nitrite and ammonium samples using four detection channels. Furthermore, the use of OSEMC for parallel and real-time analysis of flowing samples is investigated via characterization of the adsorption kinetics of tartrazine on activated charcoal and the catalytic reaction kinetics of horseradish peroxidase (HRP).


Assuntos
Técnicas Analíticas Microfluídicas , Microfluídica , Colorimetria , Peroxidase do Rábano Silvestre , Miniaturização , Reprodutibilidade dos Testes
5.
Anal Chem ; 93(44): 14859-14868, 2021 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-34705434

RESUMO

Airborne redox-active compounds (ARC) account for a substantial fraction of atmospheric aerosols and play a vital role in chemical processes that influence global climate and human and ecological health. With the exception of the determination of total organic carbon by the expensive total organic carbon (TOC) analyzer, there is currently no easy-to-use method to quantify ARC. Here, we designed a method to detect the concentration of ARC by using the thermal-induced reduction and colorimetric behaviors of gold nanoparticles (AuNPs), in which the humic substances (HS) was used as a standard model of ARC to calculate the HS-equivalent concentration of ARC. Distinguished from the conventional complex methods, e.g., TOC analysis, the proposed approach measured localized surface plasmon resonance absorption of AuNPs and the target ARC concentration can be either directly quantified by the absorption spectrometer or qualitatively evaluated by the naked eyes. By using the absorption spectrometer, a limit of detection of 0.005 ppm by our AuNP sensor was achieved. To validate this sensing technique, aerosol samples collected from Basel (suburban), Bern (urban), and Rigi mountain (rural and high-altitude) sites in Switzerland were further investigated through the TOC combustion method. The results thereby substantiated that our plasmonic absorption-based AuNP sensor upholds a great promise for fast, cost-efficient total ARC detection and air quality assessment.


Assuntos
Ouro , Nanopartículas Metálicas , Colorimetria , Calefação , Humanos , Oxirredução
6.
Environ Sci Technol ; 54(3): 1353-1362, 2020 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-31909609

RESUMO

Bioaerosols consisting of biologically originated airborne particles such as microbes, metabolites, toxins, and fragments of microorganisms are present ubiquitously in our living environment. The international interests in bioaerosols have rapidly increased because of their many potential health effects. Thus, accurate and fast detection of total bioaerosols in different environments has become an important task for safeguarding against biological threats and broadening the pool of bioaerosol knowledge. To quickly evaluate the total bioaerosol concentration, we developed a localized surface plasmon resonance biosensor based on succinimidyl-ester-functionalized gold nanoislands (SEF-AuNIs) for quantitative bioaerosol detection. The detection limit of our proposed SEF-AuNI sensors for model bacteria Escherichia coli and Bacillus subtilis can go to 0.5119 and 1.69 cells/mL, respectively. To demonstrate the capability of this bioaerosol sensing technique, we tested aerosol samples collected from Bern (urban station), Basel (suburban station), and Rigi mountain (rural and high altitude station) in Switzerland and further investigated the correlation with endotoxin and PM10. The results substantiated that our SEF-AuNI sensors could be a reliable candidate for total bioaerosol detection and air quality assessment.


Assuntos
Microbiologia do Ar , Escherichia coli , Aerossóis , Bacillus subtilis , Monitoramento Ambiental , Suíça
7.
Anal Chem ; 89(3): 1985-1993, 2017 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-28208297

RESUMO

Using self-assembly gold nanoislands (SAM-AuNIs) functionalized by poly(m-phenylenediamine-co-aniline-2-sulfonic acid) (poly(mPD-co-ASA)) copolymer nanoparticles as specific receptors, a highly sensitive localized surface plasmon resonance (LSPR) optochemical sensor is demonstrated for detection of trace lead cation (Pb(II)) in drinking water. The copolymer receptor is optimized in three aspects: (1) mole ratio of mPD:ASA monomers, (2) size of copolymer nanoparticles, and (3) surface density of the copolymer. It is shown that the 95:5 (mPD:ASA mole ratio) copolymer with size less than 100 nm exhibits the best Pb(II)-sensing performance, and the 200 times diluted standard copolymer solution contributes to the most effective functionalization protocol. The resulting poly(mPD-co-ASA)-functionalized LSPR sensor attains the detection limit to 0.011 ppb toward Pb(II) in drinking water, and the linear dynamic range covers 0.011 to 5000 ppb (i.e., 6 orders of magnitude). In addition, the sensing system exhibits robust selectivity to Pb(II) in the presence of other metallic cations as well as common anions. The proposed functional copolymer functionalized on AuNIs is found to provide excellent Pb(II)-sensing performance using simple LSPR instrumentation for rapid drinking-water inspection.


Assuntos
Compostos de Anilina/química , Água Potável/química , Ouro/química , Chumbo/análise , Nanopartículas/química , Fenilenodiaminas/química , Ressonância de Plasmônio de Superfície/métodos , Poluentes Químicos da Água/análise , Cátions Bivalentes/análise , Limite de Detecção , Oxirredução , Polimerização , Polímeros/química , Espectroscopia de Infravermelho com Transformada de Fourier
8.
Opt Lett ; 40(9): 1924-7, 2015 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-25927749

RESUMO

Self-assembly (SAM) gold nano-islands are fabricated by two-step thin-film deposition-annealing method. Despite random distribution of the SAM, the p-polarized light after total internal reflection shows significant phase transition at the extinction wavelengths upon refractive index variation due to localized surface plasmon resonance (LSPR) effect. It resembles the sharp phase transition observed in conventional surface plasmon resonance (SPR) biosensors, so that the bulk sensitivity of the SAM-LSPR sensor is improved via the phase interrogation method. In this Letter, we present both computational and experimental investigations to the SAM-LSPR sensor and the results show excellent agreement with each other. With bulk refractive index resolution to 9.75×10(-8) RIU, we believe the phase-detecting SAM-LSPR sensor would be an essential step toward low-cost label-free sensing applications.

9.
Luminescence ; 30(2): 235-9, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24954192

RESUMO

An intense green photostimulated luminescence in BaAl2 O4 :Eu(2+) phosphor was prepared. The thermoluminescence results indicate that there are at least three types of traps (T1 , T2 , T3 ) with different trap depths in BaAl2 O4 :Eu(2+) phosphor according to the bands located at 327, 361 and 555 K, respectively, which are closely associated with the phosphor's long persistent luminescence and photostimulated luminescence properties. In addition, as a novel optical read-out form, a photostimulated persistent luminescence signal can be repeatedly obtained in BaAl2 O4 :Eu(2+) phosphor. This shows that re-trapping of the electron released from a deep trap plays an important role in photostimulated persistent luminescence.


Assuntos
Óxido de Alumínio/química , Bário/química , Európio/química , Luminescência , Substâncias Luminescentes/química , Substâncias Luminescentes/síntese química , Medições Luminescentes , Processos Fotoquímicos
10.
Biosens Bioelectron ; 264: 116664, 2024 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-39159588

RESUMO

Implantable devices for brain-machine interfaces and managing neurological disorders have experienced rapid growth in recent years. Although functional implants offer significant benefits, issues related to transient trauma and long-term biocompatibility and safety are of significant concern. Acute inflammatory reaction in the brain tissue caused by microimplants is known to be an issue but remains poorly studied. This study presents the use of titanium oxynitride (TiNO) nanofilm with defined surface plasmon resonance (SPR) properties for point-of-care characterizing of acute inflammatory responses during robot-controlled micro-neuro-implantation. By leveraging surface-enriched oxynitride, TiNO nanofilms can be biomolecular-functionalized through silanization. This label-free TiNO-SPR biosensor exhibits a high sensitivity toward the inflammatory cytokine interleukin-6 with a detection limit down to 6.3 fg ml-1 and a short assay time of 25 min. Additionally, intraoperative monitoring of acute inflammatory responses during microelectrode implantation in the mice brain has been accomplished using the TiNO-SPR biosensors. Through intraoperative cerebrospinal fluid sampling and point-of-care plasmonic biosensing, the rhythm of acute inflammatory responses induced by the robot-controlled brain microelectrodes implantation has been successfully depicted, offering insights into intraoperative safety assessment of invasive brain-machine interfaces.


Assuntos
Ressonância de Plasmônio de Superfície , Titânio , Animais , Titânio/química , Camundongos , Técnicas Biossensoriais , Encefalite/etiologia , Microeletrodos , Interleucina-6/análise , Interleucina-6/líquido cefalorraquidiano , Encéfalo , Interfaces Cérebro-Computador , Desenho de Equipamento , Eletrodos Implantados/efeitos adversos , Humanos
11.
Front Immunol ; 15: 1408406, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38887291

RESUMO

Introduction: Acute respiratory distress syndrome (ARDS) is a major cause of death among critically ill patients in intensive care settings, underscoring the need to identify biomarkers capable of predicting ARDS patient clinical status and prognosis at an early time point. This study specifically sought to explore the utility and clinical relevance of TM9SF1 as a biomarker for the early prediction of disease severity and prognostic outcomes in patients with ARDS. Methods: This study enrolled 123 patients with severe ARDS and 116 patients with non-severe ARDS for whom follow-up information was available. The mRNA levels of TM9SF1 and cytokines in peripheral blood mononuclear cells from these patients were evaluated by qPCR. The predictive performance of TM9SF1 and other clinical indicators was evaluated using received operating characteristic (ROC) curves. A predictive nomogram was developed based on TM9SF1 expression and evaluated for its ability in the early prediction of severe disease and mortality in patients with ARDS. Results: TM9SF1 mRNA expression was found to be significantly increased in patients with severe ARDS relative to those with non-severe disease or healthy controls. ARDS severity increased in correspondence with the level of TM9SF1 expression (odds ratio [OR] = 2.43, 95% confidence interval [CI] = 2.15-3.72, P = 0.005), and high TM9SF1 levels were associated with a greater risk of mortality (hazard ratio [HR] = 2.27, 95% CI = 2.20-4.39, P = 0.001). ROC curves demonstrated that relative to other clinical indicators, TM9SF1 offered superior performance in the prediction of ARDS severity and mortality. A novel nomogram incorporating TM9SF1 expression together with age, D-dimer levels, and C-reactive protein (CRP) levels was developed and was used to predict ARDS severity (AUC = 0.887, 95% CI = 0.715-0.943). A separate model incorporating TM9SF1 expression, age, neutrophil-lymphocyte ratio (NLR), and D-dimer levels (C-index = 0.890, 95% CI = 0.627-0.957) was also developed for predicting mortality. Conclusion: Increases in ARDS severity and patient mortality were observed with rising levels of TM9SF1 expression. TM9SF1 may thus offer utility as a novel biomarker for the early prediction of ARDS patient disease status and clinical outcomes.


Assuntos
Biomarcadores , Síndrome do Desconforto Respiratório , Índice de Gravidade de Doença , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Citocinas/sangue , Prognóstico , Síndrome do Desconforto Respiratório/diagnóstico , Síndrome do Desconforto Respiratório/mortalidade , Curva ROC
12.
Acta Trop ; 260: 107397, 2024 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-39278519

RESUMO

Severe fever with thrombocytopenia syndrome (SFTS) is a tick-borne viral disease that is increasingly affecting human being worldwide. The clinical manifestations and mortality rates of SFTS can vary depending on the geographic region and the specific genotype of the SFTS virus (SFTSV). From July 2022 to August 2023, we collected serum samples from 83 patients with suspected SFTSV infection in the northwest of Hubei Province, China. From which, 13 patients tested positive for SFTSV. Phylogenetic analysis of the SFTSV L, M, and S gene segments was performed using the maximum likelihood method to determine the genetic diversity of the isolates. At least 2 SFTSV genotypes (A and F) were identified in the northwest of Hubei Province. The clinical manifestations and laboratory findings on the first day of admission were investigated. Results showed that bleeding and disturbance of consciousness, and significant elevated AST and APTT, are valuable for assessing the prognosis for SFTS patients. This study disclosed the genomic sequences and genotypes of SFTSV spreading in the northwest of Hubei Province for the first time, providing information of genetically etiology for SFTS in the local district. Furthermore, certain symptoms and/or laboratory findings may indicate adverse clinical outcomes, highlighting the importance of identifying the symptoms and monitoring specific laboratory markers. Future research is needed to investigate the threshold values of these markers and to closely observe the indicative symptoms in order to early identify and timely management of critically ill patients within clinical settings.

13.
Adv Sci (Weinh) ; 10(22): e2301222, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37222069

RESUMO

Airborne SARS-CoV-2 virus surveillance faces challenges in complicated biomarker enrichment, interferences from various non-specific matters and extremely low viral load in the urban ambient air, leading to difficulties in detecting SARS-CoV-2 bioaerosols. This work reports a highly specific bioanalysis platform, with an exceptionally low limit-of-detection (≤1 copy m-3 ) and good analytical accordance with RT-qPCR, relying on surface-mediated electrochemical signaling and enzyme-assisted signal amplification, enabling gene and signal amplification for accurate identification and quantitation of low doses human coronavirus 229E (HCoV-229E) and SARS-CoV-2 viruses in urban ambient air. This work provides a laboratory test using cultivated coronavirus to simulate the airborne spread of SARS-CoV-2, and validate that the platform could reliably detect airborne coronavirus and reveal the transmission characteristics. This bioassay conducts the quantitation of real-world HCoV-229E and SARS-CoV-2 in airborne particulate matters collected from road-side and residential areas in Bern and Zurich (Switzerland) and Wuhan (China), with resultant concentrations verified by RT-qPCR.


Assuntos
COVID-19 , Coronavirus Humano 229E , Humanos , SARS-CoV-2 , Material Particulado , Transdução de Sinais
14.
ACS Sens ; 7(11): 3521-3529, 2022 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-36356161

RESUMO

The laminar flow interface (LFI) developed at low Reynolds numbers is one of the most prominent features of microscale flows and has been employed in a diverse range of optofluidic applications. The formation of LFIs usually requires the manipulation of multiple streams within a microchannel using a complex hydrodynamic pumping system. Herein, we present a new type of LFI that is generated by fluid switching within a three-dimensional (3D) microlens-incorporating microfluidic chip (3D-MIMC). Since Poiseuille flows exhibit a parabolic velocity profile, the LFI is cone-like in shape and acts as a transient refractive interface (TRI), which is sensitive to the refractive index (RI) and the Péclet number (Pe) of the switching fluids. In response to the TRI, the intensity of the transmitted light can be intensified or attenuated depending on the sequence of fluid switching operations. By incorporating three-dimensional (3D) microlenses and increasing the Pe values, the profile and amplitude of the intensity peak are both significantly improved. The limit of detection (LoD) for a sodium chloride (NaCl) solution at Pe = 1363 is as low as 0.001% (w/w), representing an improvement of 1-2 orders of magnitude when compared to existing optofluidic concentration sensors based on intensity modulation. Fluid switching of a variety of inorganic and organic sample fluids confirms that the specific optical response (Kor) correlates positively with both Pe and the specific RI (Knc), obeying a linear relationship. This model is further verified through cross-validations and used to estimate the molecular diffusion coefficient (D) of a range of species. Furthermore, by virtue of the TRI, we achieve a sensitive measurement of optical-equivalent total dissolved solids (OE-TDS) for environmental samples.


Assuntos
Técnicas Analíticas Microfluídicas , Microfluídica , Técnicas Analíticas Microfluídicas/métodos , Refratometria/métodos , Hidrodinâmica
15.
ACS Appl Mater Interfaces ; 14(42): 47409-47419, 2022 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-36240070

RESUMO

Near-field optical manipulation has been widely used for guiding and trapping nanoscale objects close to an optical-active interface. This near-field manipulation opens opportunities for next-generation biosensing with the capability of large-area trapping and in situ detection. In this article, we used the finite element method (FEM) to analyze the motion mechanism of nano-objects (50-500 nm) in the near-field optics, especially localized surface plasmon resonance (LSPR). The size-dependent optical forces and hydrodynamic forces of subwavelength nanoparticles (<500 nm) in different hydrodynamic velocity fields were calculated. When the strength of the local electric field was increased, LSPR with two-dimensional gold nanoislands (AuNIs) showed improved capability for manipulating nano-objects near the vicinity of the AuNI interface. Through the experiments of in situ interferometric testing 50-500 nm nano-objects with constant number concentration or volume fraction, it was confirmed that the local plasmonic near-field was able to trap the dielectric polystyrene beads smaller than 200 nm. The plasmofluidic system was further verified by testing biological nanovesicles such as exosomes (40-200 nm) and high- and low-density lipoproteins (10-200 nm). This concept of direct dielectric nano-objects manipulation enables large-scale parallel trapping and dynamic sensing of biological nanovesicles without the need of molecular binding tethers or labeling.

16.
Environ Int ; 164: 107266, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35512527

RESUMO

Caused by the SARS-CoV-2 virus, Coronavirus disease 2019 (COVID-19) has been affecting the world since the end of 2019. While virus-laden particles have been commonly detected and studied in the aerosol samples from indoor healthcare settings, studies are scarce on air surveillance of the virus in outdoor non-healthcare environments, including the correlations between SARS-CoV-2 and other respiratory viruses, between viruses and environmental factors, and between viruses and human behavior changes due to the public health measures against COVID-19. Therefore, in this study, we collected airborne particulate matter (PM) samples from November 2019 to April 2020 in Bern, Lugano, and Zurich. Among 14 detected viruses, influenza A, HCoV-NL63, HCoV-HKU1, and HCoV-229E were abundant in air. SARS-CoV-2 and enterovirus were moderately common, while the remaining viruses occurred only in low concentrations. SARS-CoV-2 was detected in PM10 (PM below 10 µm) samples of Bern and Zurich, and PM2.5 (PM below 2.5 µm) samples of Bern which exhibited a concentration positively correlated with the local COVID-19 case number. The concentration was also correlated with the concentration of enterovirus which raised the concern of coinfection. The estimated COVID-19 infection risks of an hour exposure at these two sites were generally low but still cannot be neglected. Our study demonstrated the potential functionality of outdoor air surveillance of airborne respiratory viruses, especially at transportation hubs and traffic arteries.


Assuntos
COVID-19 , Vírus , Aerossóis , Cidades , Humanos , Pandemias , SARS-CoV-2 , Suíça/epidemiologia
17.
NanoImpact ; 27: 100414, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35961501

RESUMO

Graphene nanoplatelet (GNP) as a nanofiller improves the mechanical strength, electrical conductivity, and flame retardancy of the polymers significantly. With an increasing number of GNP-reinforced products, a careful safety assessment is needed to avoid social and economic setbacks. However, no study has addressed the effects of combustion-generated emissions from GNP-reinforced products in the lung, the most sensitive exposure route to airborne particles. Therefore, we studied the influence of GNP as a nanofiller on the emitted particles and polycyclic aromatic hydrocarbons (PAHs), and cytotoxicity of the emissions from the combustion of pure epoxy (EP) and GNP-reinforced epoxy (EP-GNP). GNP was not detected in the airborne emissions. PAHs were found in airborne particles of both emissions from EP and EP-GNP, with some differences in their concentrations. A first hazard assessment was performed on human alveolar epithelial cells exposed to the airborne emissions at air-liquid interface conditions. At 24 h and 96 h after the exposure, similar responses were observed between EP and EP-GNP except an acute transient decrease in mitochondrial activity after exposure to the emissions from EP-GNP. Both emissions from EP and EP-GNP had no acute effects on membrane integrity, cell morphology or expression of anti-oxidative stress markers (HMOX1 and SOD2 genes). Meanwhile, both emissions induced the activation of the aryl hydrocarbon receptor (CYP1A1 gene) and a transient (pro-) inflammatory response (MCP-1), but the effects between EP and EP-GNP were not significantly different.


Assuntos
Poluentes Atmosféricos , Grafite , Hidrocarbonetos Policíclicos Aromáticos , Poluentes Atmosféricos/análise , Grafite/toxicidade , Humanos , Pulmão/química , Hidrocarbonetos Policíclicos Aromáticos/toxicidade , Emissões de Veículos/análise
18.
Adv Sci (Weinh) ; 9(35): e2204774, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36310114

RESUMO

On-site quantification and early-stage infection risk assessment of airborne severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) with high spatiotemporal resolution is a promising approach for mitigating the spread of coronavirus disease 2019 (COVID-19) pandemic and informing life-saving decisions. Here, a condensation (hygroscopic growth)-assisted bioaerosol collection and plasmonic photothermal sensing (CAPS) system for on-site quantitative risk analysis of SARS-CoV-2 virus-laden aerosols is presented. The CAPS system provided rapid thermoplasmonic biosensing results after an aerosol-to-hydrosol sampling process in COVID-19-related environments including a hospital and a nursing home. The detection limit reached 0.25 copies/µL in the complex aerosol background without further purification. More importantly, the CAPS system enabled direct measurement of the SARS-CoV-2 virus exposures with high spatiotemporal resolution. Measurement and feedback of the results to healthcare workers and patients via a QR-code are completed within two hours. Based on a dose-responseµ model, it is used the plasmonic biosensing signal to calculate probabilities of SARS-CoV-2 infection risk and estimate maximum exposure durations to an acceptable risk threshold in different environmental settings.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Aerossóis e Gotículas Respiratórios , Medição de Risco , Pandemias
19.
Lab Chip ; 21(19): 3784-3792, 2021 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-34581391

RESUMO

Refractive index (RI) sensing as a label-free and non-invasive method has been playing an important role in industrial metrology, biochemical detection, and environmental analysis. Due to the combined advantages of microoptics and microfluidics, optofluidic RI sensors have attracted growing interest. Despite a variety of prototypes of optofluidic RI sensors, comprehensive improvement in sensitivity, detection range, fabrication procedures and cost can still bring substantial benefits to the field. In this work, we fabricated a 3D-cascade-microlens optofluidic chip (3DCMOC) for RI sensing. Two-photon stereolithography was employed to fabricate the chip mold, with which the 3DCMOC could be easily manufactured via mold replication. By virtue of integrating four detection channels configured with different numbers (1, 3, 5, and 7) of cascaded microlenses within the 3DCMOC, adjustable sensitivity for RI sensing has been demonstrated through measuring standard sucrose solutions. It was found that the seven-microlens configuration achieved an excellent sensitivity (mean: 21 ± 5 AU·RIU (refractive index unit)-1) and resolution (mean: 3.8 × 10-5 ± 0.9 × 10-5 RIU) at a cost of a narrow linear dynamic range (LDR, 1.3326-1.3548). In contrast, the single-microlens configuration led to an extended LDR (1.3326-1.5120 tested) despite the lower sensitivity (mean: 2.6 ± 0.2 AU·RIU-1) and resolution (mean: 1.5 × 10-4 ± 0.1 × 10-4 RIU). Furthermore, the use of the 3DCMOC was investigated via real-time salinity sensing and analysis of urine specific gravity.


Assuntos
Microfluídica , Refratometria
20.
Biosens Bioelectron ; 191: 113476, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34246124

RESUMO

Glioblastoma (GBM) is the fatal brain tumor in which secreted lactate enhances the expression of cluster of differentiation 44 (CD44) and the release of exosomes, cell-derived nanovesicles (30-200 nm), and therefore promotes tumor malignant progression. This study found that lactate-driven upregulated CD44 in malignant Glioblastoma cells (GMs) enhanced the release of CD44-enriched exosomes which increased GMs' migration and endothelial cells' tube formation, and CD44 in the secreted exosomes was sensitively detected by "capture and sensing" Titanium Nitride (TiN) - Nanoholes (NH) - discs immunocapture (TIC) - atomic force microscopy (AFM) and ultrasensitive TiN-NH-localized surface plasmon resonance (LSPR) biosensors. The limit of detection for exosomal CD44 with TIC-AFM- and TiN-NH-LSPR-biosensors was 5.29 × 10-1 µg/ml and 3.46 × 10-3 µg/ml in exosome concentration, respectively. Importantly, this work first found that label-free sensitive TiN-NH-LSPR biosensor could detect and quantify enhanced CD44 and CD133 levels in immunocaptured GMs-derived exosomes in the blood and the cerebrospinal fluid of a mouse model of GBM, supporting its potential application in a minimally invasive molecular diagnostic for GBM progression as liquid biopsy.


Assuntos
Técnicas Biossensoriais , Exossomos , Glioblastoma , Animais , Diferenciação Celular , Células Endoteliais , Biópsia Líquida , Camundongos , Microscopia de Força Atômica , Ressonância de Plasmônio de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA