Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Intensive Care Med ; 39(6): 567-576, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38105604

RESUMO

Background & Aims: This study aims to assess the application value of the real-time camera image-guided nasoenteric tube placement in critically ill COVID-19 patients undergoing endotracheal intubation and prone position ventilation therapy. Methods: We enrolled 116 COVID-19 patients receiving endotracheal intubation and prone position ventilation therapy in the intensive care unit (ICU). Patients were randomly divided into the real-time camera image-guided nasoenteric tube placement (n = 58) and bedside blind insertion (n = 58) groups. The success rate, placement time, complications, cost, heart rate, respiratory rate, Glasgow Coma Scale (GCS), and Acute Physiology and Chronic Health Evaluation II (APACHE-II) scores were compared between the 2 groups. Results: For ICU patients with COVID-19 undergoing prone position ventilation therapy, the success rate and cost were significantly higher in the real-time camera image-guided group compared to the bedside blind group (P < .05). The placement time and complication incidence were significantly lower in the real-time camera image-guided group (P < .05). The differences in heart rate, respiratory rate, GCS scores, and APACHE-II scores were insignificant (P > .05). Conclusions: The real-time camera image-guided nasoenteric tube placement system had advantages for ICU COVID-19 patients undergoing prone position ventilation therapy, including a high success rate, short placement time, and no impact on patient position during tube placement. Real-time camera image-guided nasoenteric tube placement can be performed in any position, and demonstrates high efficiency, safety, and accuracy.


Assuntos
COVID-19 , Unidades de Terapia Intensiva , Intubação Intratraqueal , Humanos , COVID-19/terapia , Masculino , Feminino , Pessoa de Meia-Idade , Decúbito Ventral , Idoso , Intubação Intratraqueal/métodos , SARS-CoV-2 , Respiração Artificial/métodos , Intubação Gastrointestinal/métodos , Adulto , Posicionamento do Paciente/métodos , Estado Terminal/terapia , APACHE , Cuidados Críticos/métodos
2.
J Stroke Cerebrovasc Dis ; 33(7): 107729, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38657830

RESUMO

BACKGROUND: Acute kidney injury (AKI) is not only a complication but also a serious threat to patients with cerebral infarction (CI). This study aimed to explore the application of interpretable machine learning algorithms in predicting AKI in patients with cerebral infarction. METHODS: The study included 3920 patients with CI admitted to the Intensive Care Unit and Emergency Medicine of the Central Hospital of Lishui City, Zhejiang Province. Nine machine learning techniques, including XGBoost, logistics, LightGBM, random forest (RF), AdaBoost, GaussianNB (GNB), Multi-Layer Perceptron (MLP), support vector machine (SVM), and k-nearest neighbors (KNN) classification, were used to develop a predictive model for AKI in these patients. SHapley Additive exPlanations (SHAP) analysis provided visual explanations for each patient. Finally, model effectiveness was assessed using metrics such as average precision (AP), sensitivity, specificity, accuracy, F1 score, precision-recall (PR) curve, calibration plot, and decision curve analysis (DCA). RESULTS: The XGBoost model performed better in the internal validation set and the external validation set, with an AUC of 0.940 and 0.887, respectively. The five most important variables in the model were, in order, glomerular filtration rate, low-density lipoprotein, total cholesterol, hemiplegia and serum kalium. CONCLUSION: This study demonstrates the potential of interpretable machine learning algorithms in predicting CI patients with AKI.


Assuntos
Injúria Renal Aguda , Infarto Cerebral , Unidades de Terapia Intensiva , Aprendizado de Máquina , Valor Preditivo dos Testes , Humanos , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/sangue , Injúria Renal Aguda/terapia , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Infarto Cerebral/diagnóstico , Infarto Cerebral/etiologia , Fatores de Risco , Medição de Risco , China/epidemiologia , Prognóstico , Reprodutibilidade dos Testes , Idoso de 80 Anos ou mais , Técnicas de Apoio para a Decisão , Estudos Retrospectivos , Diagnóstico por Computador
3.
Front Med (Lausanne) ; 10: 1226748, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37881626

RESUMO

This paper presents a comprehensive exploration of endoscopic technologies in clinical applications across seven tables, each focusing on a unique facet of the medical field. The discourse begins with a detailed analysis of pediatric endoscopes, highlighting their diagnostic capabilities in various conditions. It then delves into the specifications and applications of globally recognized capsule endoscopy devices. Additionally, the paper incorporates an analysis of advanced imaging techniques, such as Narrow Band Imaging (NBI), Flexible Spectral Imaging Color Enhancement (FICE), and i-scan, which are increasingly being integrated into ultrathin gastrointestinal (GI) endoscopes. Factors like technological capabilities, light source, camera technology, and computational constraints are evaluated to understand their compatibility with these advanced imaging techniques, each offering unique advantages and challenges in clinical settings. NBI, for instance, is lauded for its user-friendly, real-time enhanced imaging capabilities, making it effective for early detection of conditions like colorectal cancer and Barrett's esophagus. Conversely, FICE and i-scan offer high customizability and are compatible with a broader range of endoscope models. The paper further delves into innovative advances in movement control for Nasojejunal (NJ) feeding tube endoscopy, elucidating the potential of AI and other novel strategies. A review of the technologies and methodologies enhancing endoscopic procedure control and diagnostic precision follows, emphasizing image and video technologies in pediatric endoscopy, capsule endoscopes, ultrathin endoscopes, and their clinical applications. Finally, a comparative analysis of leading real-time video monitoring endoscopes in clinical practices underscores the continuous advancements in the field of endoscopy, ensuring improved diagnostics and precision in surgical procedures. Collectively, the comparative analysis presented in this paper highlights the remarkable diversity and continuous evolution of endoscopic technologies, underlining their crucial role in diagnosing and treating an array of medical conditions, thereby fostering advancements in patient care and clinical outcomes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA