Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 193
Filtrar
1.
J Pediatr ; 272: 114122, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38815742

RESUMO

OBJECTIVE: To test the hypothesis that neonates with symptomatic tetralogy of Fallot (TOF) and absent ductus arteriosus (ADA) have worse clinical outcomes compared with those with a ductus arteriosus (DA), and that this difference is driven by those born with ADA and with critically deficient pulmonary blood flow (CDPBF). STUDY DESIGN: We performed a retrospective, multicenter cohort study of neonates who underwent intervention for symptomatic TOF comparing death and reintervention between subjects with and without a DA identified on fetal echocardiogram or on echocardiogram performed in the first postnatal day. Exclusion criteria were as follows: inability to define DA status, collaterals supplying pulmonary blood flow, atrioventricular septal defect, and absent pulmonary valve. We defined CDPBF as undergoing a procedure to augment pulmonary blood flow on the date of birth or extracorporeal membrane oxygenation prior to such a procedure. RESULTS: The study cohort included 519 patients, among whom 11% had ADA. Patients with ADA were more likely to have a genetic syndrome and had smaller branch pulmonary artery size. In analyses adjusting for center, interventional treatment strategy, genetic syndrome, and minimum branch pulmonary artery size, ADA was associated with higher mortality risk (adjusted hazard ratio of 2.37 (95% CI: 1.07,5.27; P = .034). Seven patients had CDPBF (1.3% of the entire cohort and 12% of patients with ADA). CONCLUSIONS: A minority of symptomatic TOF neonates have ADA, which is associated with higher adjusted mortality risk compared with those with a DA. CDPBF appears to be a rare but important entity in this population.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38967206

RESUMO

BACKGROUND: The Alterra adaptive prestent is a novel self-expanding device designed to provide a landing zone for the 29 mm SAPIEN 3 valve to treat pulmonary regurgitation in patients with a right ventricular outflow tract that is too large for a balloon expandable valve alone. The mechanism of fixation for the Alterra prestent is radial force from the self-expanding stent frame, combined with a unique set of flared "tines" that protrude from both ends of the stent. AIMS, METHODS, AND RESULTS: In this report, we describe 6 patients who underwent uncomplicated transcatheter pulmonary valve replacement with an Alterra adaptive prestent and SAPIEN 3 valve and had surveillance chest computed tomography (CT) scans performed 1 day to 21 months after implant. In each patient, the CT scan demonstrated extravascular extension of a portion of the Alterra prestent, without clinical sequelae, but with extension into the ascending aorta in 1 patient and contact with the ascending aorta, left pulmonary vein, or left atrial appendage in 3 others. CONCLUSIONS: Surveillance CT imaging shows that the Alterra prestent can perforate the pulmonary artery and/or right ventricle. Although no sequelae were seen in these patients, prestent perforation has the potential to be clinically important. Implanters should be aware of this finding and its potential implications. As experience with the Alterra prestent grows, it will be important to further define the risk factors, incidence, and implications of this phenomenon.

3.
Catheter Cardiovasc Interv ; 103(6): 924-933, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38597297

RESUMO

BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) is a non-surgical treatment for right ventricular outflow tract (RVOT) dysfunction. During PPVI, a stented valve, delivered via catheter, replaces the dysfunctional pulmonary valve. Stent oversizing allows valve anchoring within the RVOT, but overexpansion can intrude on the surrounding structures. Potentially dangerous outcomes include aortic valve insufficiency (AVI) from aortic root (AR) distortion and myocardial ischemia from coronary artery (CA) compression. Currently, risks are evaluated via balloon angioplasty/sizing before stent deployment. Patient-specific finite element (FE) analysis frameworks can improve pre-procedural risk assessment, but current methods require hundreds of hours of high-performance computation. METHODS: We created a simplified method to simulate the procedure using patient-specific FE models for accurate, efficient pre-procedural PPVI (using balloon expandable valves) risk assessment. The methodology was tested by retrospectively evaluating the clinical outcome of 12 PPVI candidates. RESULTS: Of 12 patients (median age 14.5 years) with dysfunctional RVOT, 7 had native RVOT and 5 had RV-PA conduits. Seven patients had undergone successful RVOT stent/valve placement, three had significant AVI on balloon testing, one had left CA compression, and one had both AVI and left CA compression. A model-calculated change of more than 20% in lumen diameter of the AR or coronary arteries correctly predicted aortic valve sufficiency and/or CA compression in all the patients. CONCLUSION: Agreement between FE results and clinical outcomes is excellent. Additionally, these models run in 2-6 min on a desktop computer, demonstrating potential use of FE analysis for pre-procedural risk assessment of PPVI in a clinically relevant timeframe.


Assuntos
Cateterismo Cardíaco , Análise de Elementos Finitos , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Desenho de Prótese , Valva Pulmonar , Humanos , Valva Pulmonar/fisiopatologia , Valva Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Medição de Risco , Adolescente , Resultado do Tratamento , Fatores de Risco , Masculino , Criança , Estudos Retrospectivos , Feminino , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Adulto Jovem , Valor Preditivo dos Testes , Hemodinâmica , Stents , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Tomada de Decisão Clínica , Adulto
4.
Pediatr Radiol ; 53(3): 509-522, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36221034

RESUMO

This article reviews the physiology of the ductus arteriosus, the pathophysiology of the patent ductus arteriosus (PDA), and the role advanced imaging such as computed tomography (CT) and magnetic resonance imaging (MRI) can play in guiding diagnosis and percutaneous or surgical intervention. A PDA can have variable clinical and radiologic presentations and can be important to characterize in patients with vascular rings, aortic maldevelopment and congenital heart disease. An understanding of the PDA and the application of CT and MRI can allow the radiologist to provide key information to physicians who plan to close a PDA or maintain PDA patency in the setting of ductal-dependent congenital heart disease.


Assuntos
Permeabilidade do Canal Arterial , Canal Arterial , Cardiopatias Congênitas , Humanos , Canal Arterial/patologia , Aorta , Tomografia Computadorizada por Raios X
5.
Pediatr Cardiol ; 2023 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-37210685

RESUMO

Single ventricle patients eligible for Fontan completion undergo pre-Fontan catheterization for hemodynamic and anatomic assessment prior to surgery. Cardiac magnetic resonance imaging may be used to evaluate pre-Fontan anatomy, physiology, and collateral burden. We describe our center's outcomes in patients undergoing pre-Fontan catheterization combined with cardiac magnetic resonance imaging. A retrospective review of patients undergoing pre-Fontan catheterization from 10/2018 to 04/2022 at Texas Children's Hospital was performed. Patients were divided into 2 groups: combined cardiac magnetic resonance imaging and catheterization (combined group) and those who underwent catheterization only (catheterization only group). There were 37 patients in the combined group and 40 in the catheterization only group. Both groups were similar in age and weight. Patients undergoing combined procedures received less contrast, and experienced less in-lab time, fluoroscopy time and catheterization procedure time. Median radiation exposure was lower in the combined procedure group but was not statistically significant. Intubation and total anesthesia times were higher in the combined procedure group. Patients undergoing a combined procedure were less likely to have collateral occlusion performed than in the catheterization only group. Bypass time, intensive care unit length of stay, and chest tube duration were similar in both groups at the time of Fontan completion. Combined pre-Fontan assessment decreases catheterization procedure and fluoroscopy time associated with cardiac catheterization at the expense of longer anesthetic times, and results in similar Fontan outcomes compared to when cardiac catheterization alone is utilized.

6.
Cardiol Young ; 33(11): 2282-2290, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36705001

RESUMO

OBJECTIVES: To determine the safety and feasibility of over-expansion of right ventricle to pulmonary artery conduits during transcatheter pulmonary valve placement. BACKGROUND: Transcatheter pulmonary valve placement is an alternative to surgical pulmonary valve replacement. Traditionally, it was thought to be unsafe to expand a conduit to >110% of its original size. METHODS: This retrospective cohort study from two centers includes patients with right ventricle to pulmonary artery conduits with attempted transcatheter pulmonary valve placement from 2010 to 2017. Demographic, procedural, echocardiographic and follow-up data, and complications were evaluated in control and overdilation (to >110% original conduit size) groups. RESULTS: One hundred and seventy-two patients (51 overdilation and 121 control) had attempted transcatheter pulmonary valve placement (98% successful). The overdilation group was younger (11.2 versus 16.7 years, p < 0.001) with smaller conduits (15 versus 22 mm, p < 0.001); however, the final valve size was not significantly different (19.7 versus 20.2 mm, p = 0.2). Baseline peak echocardiographic gradient was no different (51.8 versus 55.6 mmHg, p = 0.3). Procedural complications were more frequent in overdilation (18%) than control (7%) groups (most successfully addressed during the procedure). One patient from each group required urgent surgical intervention, with no procedural mortality. Follow-up echocardiographic peak gradients were similar (24.1 versus 26 mmHg, p = 0.5). CONCLUSIONS: Over-expansion of right ventricle to pulmonary artery conduits during transcatheter pulmonary valve placement can be performed successfully. Procedural complications are more frequent with conduit overdilation, but there was no difference in the rate of life-threatening complications. There was no difference in valve function at most recent follow-up, and no difference in rate of reintervention. The long-term outcomes of transcatheter pulmonary valve placement with conduit over-expansion requires further study.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Pulmonar , Humanos , Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Desenho de Prótese , Cateterismo Cardíaco/métodos
7.
Cardiol Young ; 33(12): 2621-2627, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37092668

RESUMO

BACKGROUND: Fontan baffle punctures and creation of Fontan fenestration for cardiac catheterisation procedures remain challenging especially due to the heavy calcification of prosthetic material and complex anatomy. OBJECTIVES: We sought to evaluate our experience using radiofrequency current via surgical electrocautery needle for Fontan baffle puncture to facilitate diagnostic, electrophysiology, and interventional procedures. METHODS: A retrospective chart review of all Fontan patients (pts) who underwent Fontan baffle puncture using radiofrequency energy via surgical electrocautery from three centres were performed from January 2011 to July 2021. RESULTS: A total of 19 pts underwent 22 successful Fontan baffle puncture. The median age and weight were 17 (3-36 years) and 55 (14-88) kg, respectively. The procedural indications for Fontan fenestration creation included: diagnostic study (n = 1), atrial septostomy and stenting (n = 1), electrophysiology study and ablation procedures (n = 8), Fontan baffle stenting for Fontan failure including protein-losing enteropathy (n = 7), and occlusion of veno-venous collaterals (n = 2) for cyanosis. The type of Fontan baffles included: extra-cardiac conduits (n = 12), lateral tunnel (n = 5), classic atrio-pulmonary connection (n = 1), and intra-cardiac baffle (n = 1). A Fontan baffle puncture was initially attempted using traditional method in 6 pts and Baylis radiofrequency trans-septal system in 2 pts unsuccessfully. In all pts, Fontan baffle puncture using radiofrequency energy via electrocautery needle was successful. The radiofrequency energy utilised was (10-50 W) and required 1-5 attempts for 2-5 seconds. There were no vascular or neurological complications. CONCLUSIONS: Radiofrequency current delivery using surgical electrocautery facilitates Fontan baffle puncture in patients with complex and calcified Fontan baffles for diagnostic, interventional, and electrophysiology procedures.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Humanos , Cardiopatias Congênitas/complicações , Estudos Retrospectivos , Coração , Cateterismo Cardíaco , Eletrocoagulação , Resultado do Tratamento
8.
Cardiol Young ; 33(11): 2342-2349, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36861393

RESUMO

BACKGROUND: Anomalous aortic origin of the left coronary artery with intraseptal course is a rare coronary anomaly associated with an increased risk of myocardial ischaemia. The role and techniques for surgical intervention are evolving, with numerous novel surgical techniques for this challenging anatomy reported in the last 5 years. We report our single-centre experience with surgical repair of intraseptal anomalous left coronary artery in the paediatric population, including clinical presentation, evaluation, and short- to mid-term outcomes. METHODS: All patients with coronary anomalies presenting to our institution undergo standardised clinical evaluation. Five patients aged 4 to 17 years underwent surgical intervention for intraseptal anomalous aortic origin of the left coronary artery between 2012 and 2022. Surgical techniques included coronary artery bypass grafting (n = 1), direct reimplantation with limited supra-arterial myotomy via right ventriculotomy (n = 1), and transconal supra-arterial myotomy with right ventricular outflow tract patch reconstruction (n = 3). RESULTS: All patients had evidence of haemodynamically significant coronary compression, and three had evidence of inducible myocardial ischaemia pre-operatively. There were no deaths or major complications. Median follow-up was 6.1 months (range 3.1-33.4 months). Patients who underwent supra-arterial myotomy (with or without reimplantation) had improved coronary flow and perfusion based on stress imaging and catheterisation data. CONCLUSIONS: Surgical approaches to intraseptal anomalous left coronary artery with evidence of myocardial ischaemia continue to evolve, with new techniques demonstrating promising improvement in coronary perfusion. Further studies are warranted to determine long-term outcomes and refine indications for repair.


Assuntos
Artéria Coronária Esquerda Anormal , Doença da Artéria Coronariana , Anomalias dos Vasos Coronários , Isquemia Miocárdica , Criança , Humanos , Artéria Coronária Esquerda Anormal/complicações , Anomalias dos Vasos Coronários/diagnóstico , Anomalias dos Vasos Coronários/cirurgia , Anomalias dos Vasos Coronários/complicações , Isquemia Miocárdica/complicações , Isquemia Miocárdica/cirurgia , Doença da Artéria Coronariana/complicações , Aorta/anormalidades , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
9.
J Pediatr ; 250: 22-28.e4, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35772511

RESUMO

OBJECTIVE: To evaluate early growth following primary or staged repair of neonatal symptomatic tetralogy of Fallot (sTOF). STUDY DESIGN: We performed a retrospective, multicenter cohort study of consecutive infants with sTOF who underwent initial intervention at age ≤30 days, from 2005 to 2017. Management strategies were either primary repair or staged repair (ie, initial palliation followed by complete repair). The primary outcome was change in weight-for-age z-score (ΔWAZ) from the initial intervention to age 6 ± 2 months. Secondary outcomes included method and mode of feeding, feeding-related medications, and feeding-related readmissions. Propensity score adjustment was used to account for baseline differences between groups. A secondary analysis was performed comparing patients stratified by the presence of adequate growth (6-month ΔWAZ > -0.5) or inadequate growth (6-month ΔWAZ ≤ -0.5), independent of treatment strategy. RESULTS: The study cohort included 143 primary repair subjects and 240 staged repair subjects. Prematurity was more common in the staged repair group. After adjustment, median ΔWAZ did not differ between treatment groups over the first 6 months of life (primary: -0.43 [IQR, -1.17 to 0.50]; staged: -0.31 [IQR, -1.31 to 0.71]; P = .55). For the entire cohort, ΔWAZ was negative (-0.36; IQR, -1.21 to 0.63). There were no between-group differences in the secondary outcomes. Secondary analysis revealed that the subjects with adequate growth were more likely to be orally fed at initial hospital discharge (P = .04). CONCLUSIONS: In neonates with sTOF, growth trajectory over the first 6 months of life was substandard, irrespective of treatment strategy. Those patients with adequate growth were more likely to be discharged from the index procedure on oral feeds.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Tetralogia de Fallot , Humanos , Lactente , Recém-Nascido , Tetralogia de Fallot/cirurgia , Estudos Retrospectivos , Estudos de Coortes , Resultado do Tratamento , Procedimentos Cirúrgicos Cardíacos/métodos
10.
Catheter Cardiovasc Interv ; 100(4): 596-605, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35904221

RESUMO

BACKGROUND: Morbidity with surgical systemic-to-pulmonary artery shunting (SPS) in infants ≤2.5 kg has remained high. Patent ductus arteriosus (PDA) stenting may be a valid alternative. The objective of this study is to evaluate outcomes following PDA stenting in patients ≤2.5 kg from four large tertiary centers. METHODS: Retrospective review of all neonates ≤2.5 kg with duct-dependent pulmonary circulation who underwent PDA stenting. Procedural details, pulmonary arterial growth, reinterventions, surgery type, and outcomes were assessed. RESULTS: PDA stents were implanted in 37 of 38 patients attempted (18 female) at a median procedural weight of 2.2 kg (interquartile range [IQR], 2-2.4 kg). Seven patients (18%) had a genetic abnormality and 16 (42%) had associated comorbidities. The median intensive care unit stay was 4 days (IQR, 2-6.75 days), and the median hospital stay was 20 days (IQR, 16-57.25). One patient required a rescue shunt procedure, with three others requiring early SPS (<30 days postprocedure). Twenty patients (54%) required reintervention with either balloon angioplasty, restenting, or both. At 6-month follow-up, right pulmonary artery growth (median z-score -1.16 to 0.01, p = 0.05) was greater than the left pulmonary artery (median z-score -0.9 to -0.64, p = 0.35). Serious adverse effects (SAEs) were seen in 18% (N = 7) of our cohort. One patient developed an SAE during planned reintervention There were no intraprocedural deaths, with one early procedure-related mortality, and three interstage mortalities not directly related to PDA stenting. CONCLUSIONS: PDA stenting in infants ≤2.5 kg is feasible and effective, promoting pulmonary artery growth. Reintervention rates are relatively high, though many are planned to allow for optimal growth before a definitive operation.


Assuntos
Permeabilidade do Canal Arterial , Canal Arterial , Cateterismo Cardíaco/efeitos adversos , Permeabilidade do Canal Arterial/complicações , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/terapia , Feminino , Humanos , Lactente , Recém-Nascido , Circulação Pulmonar , Estudos Retrospectivos , Stents , Resultado do Tratamento
11.
Liver Int ; 42(4): 879-883, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35129262

RESUMO

Portal hypertension because of liver cirrhosis is a significant cause of morbidity and mortality. Treatment options in these patients include liver transplant, symptomatic treatment of oesophageal varices via endoscopic treatment and symptomatic management of ascites. Portosystemic shunt creation can be challenging in newborns and infants. We present a newborn with Trisomy 21, severe portal hypertension secondary to neonatal cirrhosis, oesophageal varices and upper GI bleeding, severe ascites refractory to medical management who underwent ductus venosus stenting as a palliative procedure. He demonstrated remarkable clinical improvement with no subsequent upper GI bleed and resolution of ascites till his last follow-up at 12 months of age. To the best of our knowledge, stenting of the patent ductus venosus to create a portosystemic shunt to relieve portal hypertension has not been reported in English literature.


Assuntos
Varizes Esofágicas e Gástricas , Hipertensão Portal , Derivação Portossistêmica Transjugular Intra-Hepática , Ascite/complicações , Ascite/terapia , Varizes Esofágicas e Gástricas/complicações , Varizes Esofágicas e Gástricas/terapia , Hemorragia Gastrointestinal/complicações , Hemorragia Gastrointestinal/terapia , Humanos , Hipertensão Portal/complicações , Lactente , Recém-Nascido , Cirrose Hepática/complicações , Masculino , Veia Porta , Derivação Portossistêmica Transjugular Intra-Hepática/efeitos adversos
12.
Artigo em Inglês | MEDLINE | ID: mdl-35835516

RESUMO

To this day, controversy still exists regarding the optimal method to treat symptomatic neonates and infants with Tetralogy of Fallot (TOF). Symptomatic (severely cyanotic or ductal dependent) infants with TOF can undergo either a staged repair approach (consisting of initial palliation followed by complete repair) or primary repair. Traditionally, initial palliative procedures have been surgical, for example placement of a Blalock-Taussig-Thomas (BTT) shunt. Recent advances in technology have facilitated the introduction of catheter-based procedures as palliative techniques, for example, patent ductus arteriosus (PDA) stenting and right ventricular outflow tract (RVOT) stenting as more durable solutions than balloon pulmonary valvuloplasty (BPV). In this article, we discuss the rationale for these procedures, technical aspects of these procedures and outcomes data compared to traditional surgical procedures. Recent data have suggested that RVOT and PDA stenting procedures offer many advantages over traditional surgical palliative procedures as palliative methods in this patient population. This comes at a cost of increased reintervention burden, which may be considered part of the overall treatment strategy in smaller neonates and can be minimized with a focus on technical aspects and overall treatment strategies. Advanced surgical techniques are required at the eventual complete repair to negotiate removal of stent material and pulmonary artery reconstruction in some instances. Further adoption of catheter based palliative procedures for infants with symptomatic TOF has the potential to tip the outcomes towards favoring a staged approach, particularly in high-risk infants.


Assuntos
Procedimento de Blalock-Taussig , Permeabilidade do Canal Arterial , Tetralogia de Fallot , Permeabilidade do Canal Arterial/cirurgia , Humanos , Lactente , Recém-Nascido , Cuidados Paliativos/métodos , Estudos Retrospectivos , Stents , Tetralogia de Fallot/cirurgia , Resultado do Tratamento
13.
Pediatr Cardiol ; 43(1): 104-109, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34363498

RESUMO

Pediatric cardiac interventions via percutaneous common carotid artery (CCA) access have been shown to be safe and effective. However, the impact of placement of a sheath in the carotid artery for interventions on cerebral perfusion is unknown. In this study we used cerebral near-infrared spectroscopy (NIRS) to analyze the effects of percutaneous CCA access for cardiac interventions on cerebral perfusion. This study is a retrospective chart review carried out at a tertiary care center on all pediatric patients who underwent percutaneous cardiac catheterization via carotid artery access from January 2010 to January 2020. All patients who had ipsilateral NIRS recorded on the side of carotid artery access were included. Patients with only partial or no ipsilateral NIRS data were excluded. The primary outcome measure was the change in NIRS upon CCA access; the mean NIRS for 15 min before obtaining access was compared to the mean NIRS during the procedure and to the mean NIRS 15 min after removal of the CCA sheath. We hypothesized that there would be a significant drop in NIRS values on the side of CCA access. There were 48 catheterizations in the study period where percutaneous CCA was accessed. Of those, 21 catheterizations had complete data and were included in the study. 13 (62%) were of males. The median age was 23 days (IQR 7-79). The indications for CCA access were patent ductus arteriosus stent implantation (n = 13; 62%), aortic valvuloplasty (n = 5; 24%), balloon angioplasty of coarctation of aorta (n = 2; 10%), and renal artery angioplasty (n = 1; 4%). In 16 patients (72%), the left common carotid artery was accessed. The median weight of the patients was 3.3 kg (IQR 2.8-2.9). The most common sheath size used was 4F, in 16 patients (72%). The mean NIRS prior to the procedure was 67 ± 15%, during the procedure was 68 ± 20%, and after removal of sheath was 68 ± 21%. Paired t test of cerebral NIRS before, during, and after the procedure showed no significant change with CCA access (P = 0.08). No patient in the series had a documented neurologic deficit following the procedure. Percutaneous CCA access was not associated with a decrease in NIRS on the side of the access during the procedure, suggesting there was no significant acute change in cerebral perfusion with CCA access.


Assuntos
Artérias Carótidas , Artéria Carótida Primitiva , Adulto , Artéria Carótida Primitiva/diagnóstico por imagem , Circulação Cerebrovascular , Criança , Humanos , Lactente , Masculino , Estudos Retrospectivos , Stents , Resultado do Tratamento , Adulto Jovem
14.
Pediatr Cardiol ; 43(1): 121-131, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34524483

RESUMO

Patent ductus arteriosus (PDA) stenting is an accepted method for securing pulmonary blood flow in cyanotic neonates. In neonates with pulmonary atresia and single source ductal-dependent pulmonary blood flow (SSPBF), PDA stenting remains controversial. We sought to evaluate outcomes in neonates with SSPBF, comparing PDA stenting and surgical Blalock-Taussig shunt (BTS). Neonates with SSPBF who underwent PDA stenting or BTS at the four centers of the Congenital Catheterization Research Collaborative from January 2008 to December 2015 were retrospectively reviewed. Reintervention on the BTS or PDA stent prior to planned surgical repair served as the primary endpoint. Additional analyses of peri-procedural complications, interventions, and pulmonary artery growth were performed. A propensity score was utilized to adjust for differences in factors. Thirty-five patients with PDA stents and 156 patients with BTS were included. The cohorts had similar baseline characteristics, procedural complications, and mortality. Interstage reintervention rates were higher in the PDA stent cohort (48.6% vs. 15.4%, p < 0.001).


Assuntos
Procedimento de Blalock-Taussig , Permeabilidade do Canal Arterial , Canal Arterial , Cateterismo Cardíaco , Canal Arterial/cirurgia , Permeabilidade do Canal Arterial/cirurgia , Humanos , Recém-Nascido , Artéria Pulmonar/cirurgia , Circulação Pulmonar , Estudos Retrospectivos , Stents , Resultado do Tratamento
15.
Pediatr Cardiol ; 43(7): 1587-1598, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35381860

RESUMO

Neonates with symptomatic tetralogy of Fallot (sTOF) may undergo palliations with varying physiology, namely systemic to pulmonary artery connections (SPC) or right ventricular outflow tract interventions (RVOTI). A comparison of palliative strategies based on the physiology created is lacking. Consecutive sTOF neonates undergoing SPC or RVOTI from 2005-2017 were reviewed from the Congenital Cardiac Research Collaborative. The primary outcome was survival with successful complete repair (CR) by 18 months. A variety of secondary outcomes were assessed including overall survival, hospitalization-related comorbidities, and interstage reinterventions. Propensity score adjustment was utilized to compare treatment strategies. The cohort included 252 SPC (surgical shunt = 226, ductus arteriosus stent = 26) and 68 RVOTI (balloon pulmonary valvuloplasty = 48, RVOT stent = 11, RVOT patch = 9) patients. Genetic syndrome (29 [42.6%] v 75 [29.8%], p = 0.04), weight < 2.5 kg (28 [41.2%] v 68 [27.0%], p = 0.023), bilateral pulmonary artery Z-score < - 2 (19 [28.0%] v 36 [14.3%], p = 0.008), and pre-intervention antegrade flow (48 [70.6%] v 104 [41.3%], p < 0.001) were more common in RVOTI. Significant center differences were noted (p < 0.001). Adjusted survival to CR by 18 months (HR = 0.87, 95% CI = 0.63-1.21, p = 0.41) and overall survival (HR = 2.08, 95% CI = 0.93-4.65, p = 0.074) were similar. RVOTI had increased interstage reintervention (HR = 2.15, 95% CI = 1.36-3.99, p = 0.001). Total anesthesia (243 [213, 277] v 328 [308, 351] minutes, p < 0.001) and cardiopulmonary bypass times (117 [103, 132] v 151 [143, 160] minutes, p < 0.001) favored RVOTI. In this multicenter comparison of physiologic palliation strategies for sTOF, survival to successful CR and overall survival were similar; however, reintervention burden was significantly higher in RVOTI.


Assuntos
Procedimento de Blalock-Taussig , Tetralogia de Fallot , Humanos , Lactente , Recém-Nascido , Cuidados Paliativos , Artéria Pulmonar/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
16.
Cardiol Young ; 32(12): 1952-1956, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35152927

RESUMO

BACKGROUND: Recurrent laryngeal nerve injury leading to vocal cord paralysis is a known complication of cardiothoracic surgery. Its occurrence during interventional catheterisation procedures has been documented in case reports, but there have been no studies to determine an incidence. OBJECTIVE: To establish the incidence of left recurrent laryngeal nerve injury leading to vocal cord paralysis after left pulmonary artery stenting, patent ductus arteriosus device closure and the combination of the procedures either consecutively or simultaneously. METHODS: Members of the Congenital Cardiovascular Interventional Study Consortium were asked to perform a retrospective analysis to identify cases of recurrent laryngeal nerve injury after the aforementioned procedures. Twelve institutions participated in the analysis. They also contributed the total number of each procedure performed at their respective institutions for statistical purposes. RESULTS: Of the 1337 patients who underwent left pulmonary artery stent placement, six patients (0.45%) had confirmed vocal cord paralysis. 4001 patients underwent patent ductus arteriosus device closure, and two patients (0.05%) developed left vocal cord paralysis. Patients who underwent both left pulmonary artery stent placement and patent ductus arteriosus device closure had the highest incidence of vocal cord paralysis which occurred in 4 of the 26 patients (15.4%). Overall, 92% of affected patients in our study population had resolution of symptoms. CONCLUSION: Recurrent laryngeal nerve injury is a rare complication of left pulmonary artery stent placement or patent ductus arteriosus device closure. However, the incidence is highest in patients undergoing both procedures either consecutively or simultaneously. Additional research is necessary to determine contributing factors that might reduce the risk of recurrent laryngeal nerve injury.


Assuntos
Permeabilidade do Canal Arterial , Traumatismos do Nervo Laríngeo Recorrente , Paralisia das Pregas Vocais , Humanos , Traumatismos do Nervo Laríngeo Recorrente/etiologia , Traumatismos do Nervo Laríngeo Recorrente/complicações , Paralisia das Pregas Vocais/epidemiologia , Paralisia das Pregas Vocais/etiologia , Permeabilidade do Canal Arterial/epidemiologia , Permeabilidade do Canal Arterial/cirurgia , Permeabilidade do Canal Arterial/complicações , Incidência , Estudos Retrospectivos , Cateterismo/efeitos adversos
17.
J Card Surg ; 36(4): 1352-1360, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33604954

RESUMO

INTRODUCTION: The optimal management of scimitar syndrome remains incompletely defined. We (1) evaluated the impact of aortopulmonary collateral (APC) occlusion, (2) compared outcomes according to surgical approach for patients who underwent surgery, and (3) identified anatomic factors associated with longer survival time without scimitar vein repair. METHODS: We conducted a single center, retrospective study of 61 patients diagnosed with scimitar syndrome between 1995 and 2019. Right pulmonary artery to total pulmonary artery cross-sectional area (RPA:PA CSA) quantitatively assessed right pulmonary artery size. Anatomical features were analyzed for association with longer survival time without scimitar vein repair. RESULTS: Median follow-up time was 6 years (Q1-Q3, 2-12), with 96% 5-year survival. Twenty-three patients underwent APC occlusion, which significantly decreased symptoms of overcirculation (100%-46%; p = .001) and systolic pulmonary artery pressure (median, 34-29 mmHg; p = .004). Twenty-three patients underwent scimitar vein repair; 5-year freedom from scimitar vein stenosis was 90% among patients who underwent a reimplantation compared with 42% in patients with baffle repair (p = .1). Three patients underwent surgery before the first year of age, with lower 5-year freedom from scimitar vein stenosis (0% vs. 84%; p < .001). On multivariate analysis, a lower RPA:PA CSA was associated with longer survival time without scimitar vein repair (p = .003). CONCLUSIONS: APC occlusion improves the clinical status of young and hemodynamically unstable patients. Repair at an early age is associated with an increased risk of scimitar vein stenosis. Scimitar vein repair might be avoided in patients with a smaller right pulmonary artery.


Assuntos
Veias Pulmonares , Síndrome de Cimitarra , Humanos , Lactente , Pulmão , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Síndrome de Cimitarra/cirurgia , Procedimentos Cirúrgicos Vasculares
18.
Pediatr Cardiol ; 42(3): 533-542, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33394118

RESUMO

Isolated pulmonary artery (PA) of ductal origin (IPADO) is a rare cardiac defect which requires surgical repair, with or without preceding palliation. We sought to determine the impact of treatment strategy on outcomes. Retrospective study of consecutive patients with IPADO that underwent staged or primary repair from 1/05 to 9/16 at 6 Congenital Cardiac Research Collaborative centers. Patients with single ventricle physiology, major aortopulmonary collaterals, or bilateral IPADO were excluded. Primary outcome was isolated PA z-score at late follow-up. Secondary outcomes included PA symmetry index (isolated:confluent PA diameter) and reintervention burden. Propensity score adjustment was used to account for baseline differences. Of 60 patients in the study cohort, 26 (43%) underwent staged and 34 (57%) primary repair. The staged and primary repair groups differed in weight at diagnosis and presence of other heart disease but not in baseline PA dimensions. Staged patients underwent ductal stent (n = 16) or surgical shunt (n = 10) placement followed by repair at 210 vs. 21 days in the primary repair group (p < 0.001). At median follow-up of 4.5 years post-repair, after adjustment, isolated PA z-score (- 0.74 [- 1.75, - 0.26] vs. - 1.95 [- 2.91, - 1.59], p = 0.012) and PA symmetry index (0.81 [0.49, 1.0] vs. 0.55 [0.48, 0.69], p = 0.042) significantly favored the staged repair group. Freedom from PA reintervention was not different between groups (adjusted HR 0.78 [0.41, 1.48]; p = 0.445). A staged approach to repair of IPADO is associated with superior isolated PA size and symmetry at late follow-up. Consideration should be given to initial palliation in IPADO patients, when feasible.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Cardiopatias Congênitas/cirurgia , Artéria Pulmonar/anormalidades , Artéria Pulmonar/cirurgia , Cateterismo Cardíaco/métodos , Permeabilidade do Canal Arterial/cirurgia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Cuidados Paliativos/métodos , Reoperação/métodos , Estudos Retrospectivos , Stents , Resultado do Tratamento
19.
Cardiol Young ; 31(12): 1885-1892, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34620264

RESUMO

Ostium secundum atrial septal defects are mostly closed in the cardiac catheterisation laboratories using either Amplatzer® (Abbott Laboratories, IL) atrial septal occluder, Gore® Cardioform septal occluder and more recently using the recently approved (US FDA approval June 2019) Gore® Cardioform atrial septal defect occluder (W. L. Gore & Associates, AZ). Similar to any new device in the market, there is a learning curve to the deployment of this device. We therefore aim to report the key features about this new Gore Cardioform atrial septal defect occluder device with special emphasis on technical aspects that can be employed during transcatheter closure of challenging ostium secundum atrial septal defects using this device.


Assuntos
Forame Oval Patente , Comunicação Interatrial , Dispositivo para Oclusão Septal , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Humanos , Desenho de Prótese , Dispositivo para Oclusão Septal/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
20.
Cardiol Young ; 31(11): 1829-1834, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33726868

RESUMO

BACKGROUND: Multicentre research databases can provide insights into healthcare processes to improve outcomes and make practice recommendations for novel approaches. Effective audits can establish a framework for reporting research efforts, ensuring accurate reporting, and spearheading quality improvement. Although a variety of data auditing models and standards exist, barriers to effective auditing including costs, regulatory requirements, travel, and design complexity must be considered. MATERIALS AND METHODS: The Congenital Cardiac Research Collaborative conducted a virtual data training initiative and remote source data verification audit on a retrospective multicentre dataset. CCRC investigators across nine institutions were trained to extract and enter data into a robust dataset on patients with tetralogy of Fallot who required neonatal intervention. Centres provided de-identified source files for a randomised 10% patient sample audit. Key auditing variables, discrepancy types, and severity levels were analysed across two study groups, primary repair and staged repair. RESULTS: Of the total 572 study patients, data from 58 patients (31 staged repairs and 27 primary repairs) were source data verified. Amongst the 1790 variables audited, 45 discrepancies were discovered, resulting in an overall accuracy rate of 97.5%. High accuracy rates were consistent across all CCRC institutions ranging from 94.6% to 99.4% and were reported for both minor (1.5%) and major discrepancies type classifications (1.1%). CONCLUSION: Findings indicate that implementing a virtual multicentre training initiative and remote source data verification audit can identify data quality concerns and produce a reliable, high-quality dataset. Remote auditing capacity is especially important during the current COVID-19 pandemic.


Assuntos
COVID-19 , Confiabilidade dos Dados , Humanos , Recém-Nascido , Pandemias , Estudos Retrospectivos , SARS-CoV-2
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA