Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Pediatr Emerg Care ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38941106

RESUMO

ABSTRACT: Musculoskeletal and soft tissue complaints commonly present to the pediatric emergency department and literature supports the use point-of-care ultrasound (POCUS) in the diagnosis of these complaints. The diagnosis of osteomyelitis typically involves laboratory testing with inflammatory biomarkers, imaging with x-ray, and often magnetic resonance imaging with test results often not immediately available. We report a case series of children initially evaluated with POCUS for osteomyelitis. The POCUS may expedite diagnosis and treatment when used as the initial test in children with suspected osteomyelitis in the emergency department.

2.
Pediatr Emerg Care ; 40(11): 822-824, 2024 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-39475929

RESUMO

ABSTRACT: Point-of-care ultrasound has been shown to be effective in diagnosing many types of fractures, including nasal fractures, but it is not commonly used in pediatrics to diagnose mandibular fractures. We describe a case of a mandibular fracture diagnosed by point-of-care ultrasound in the pediatric emergency department. Additional studies are needed in the pediatric population to determine if point-of-care ultrasound can diagnose mandibular fracture rapidly and accurately, expediting diagnosis and potentially minimizing exposure to ionizing radiation in patients with no point-of-care ultrasound evidence of mandibular fracture.


Assuntos
Fraturas Mandibulares , Sistemas Automatizados de Assistência Junto ao Leito , Ultrassonografia , Humanos , Fraturas Mandibulares/diagnóstico por imagem , Ultrassonografia/métodos , Masculino , Serviço Hospitalar de Emergência , Criança
3.
Pediatr Emerg Care ; 40(8): 603-606, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38776424

RESUMO

OBJECTIVES: Asthma is a leading cause of pediatric emergency department visits, yet few tools exist to objectively measure asthma severity. Diaphragmatic ultrasound (DUS) is a novel method of assessing respiratory distress; however, data are lacking for children.Our primary aim was to determine if diaphragmatic excursion (DE), diaphragmatic thickening (DT), or diaphragmatic thickening fraction (TF) correlated with asthma severity as determined by the Pediatric Respiratory Assessment Measure (PRAM) score. Secondarily, we examined if these parameters correlated with need for respiratory support and evaluated interrater reliability. METHODS: We conducted a prospective study of children 5-18 years presenting to a pediatric emergency department with an asthma exacerbation. Diaphragmatic ultrasound was performed by a trained pediatric emergency medicine sonologist in subcostal (DE) and midaxillary (DT). Thickening fraction was calculated from DT values as previously described in literature. To evaluate interrater reliability, a subset of subjects had DUS performed by a second sonologist. RESULTS: We enrolled 47 subjects for a total of 51 encounters. The mean age was 9.1 ± 3.7 years. Twenty-five (49%) had mild, 24 (47%) had moderate, and 2 (4%) had severe asthma. There was a significant difference in midaxillary DT and TF between children with mild and moderate asthma ( P = 0.02; mean difference, 0.2 mm; 95% confidence interval [CI], 0.03-0.4 and P = 0.02; mean difference, 0.11 mm; 95% CI, 0.02-0.2, respectively). No difference was found in subcostal DE ( P = 0.43; mean difference, 1.4 mm; 95% CI, -2.1 to 4.8). No association was found between use of positive pressure and DUS parameters. Fourteen encounters had 2 sonologists perform DUS, with strong interrater reliability found for midaxillary DT (Pearson correlation, 0.56) and poor association for subcostal DE (Pearson correlation, 0.18). CONCLUSIONS: In this pilot study, we conclude that DUS may be helpful in assessing severity of asthma. The midaxillary view assessment for DT and TF had the best correlation with asthma severity and the best interrater reliability. Future studies may benefit from focusing on the midaxillary view for DT and TF.


Assuntos
Asma , Diafragma , Serviço Hospitalar de Emergência , Ultrassonografia , Humanos , Criança , Asma/diagnóstico por imagem , Estudos Prospectivos , Masculino , Feminino , Diafragma/diagnóstico por imagem , Adolescente , Pré-Escolar , Ultrassonografia/métodos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
4.
Pediatr Emerg Care ; 2024 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-39332825

RESUMO

ABSTRACT: Point-of-care ultrasound (POCUS) can expedite the diagnosis of pediatric abdominal pathologies including appendicitis and intussusception. In this patient series, we present cases from multiple pediatric emergency departments that demonstrate the use of POCUS in the diagnosis of trichobezoars in children. POCUS findings include the presence of an intragastric hyperechoic mass or a hyperechoic arch and associated posterior acoustic shadowing. These findings in the appropriate clinical context should prompt further diagnostic imaging and/or surgical consultation for removal.

5.
Pediatr Blood Cancer ; 70(1): e30063, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36308736

RESUMO

Sickle cell disease is the most prevalent inherited blood disorder in the world, with significant morbidity and mortality. Patients often have recurrent painful vaso-occlusive episodes, and the American Society of Hematology gives a conditional recommendation for the use of regional anesthesia for acute sickle cell pain management. This scoping review summarizes the current evidence and identifies gaps for future research. Our screening process is outlined, and articles that mentioned the use of regional anesthesia for acute sickle cell crises were included. We present and interpret our results and highlight opportunities for future investigation.


Assuntos
Dor Aguda , Anemia Falciforme , Anestesia por Condução , Humanos , Dor Aguda/etiologia , Anemia Falciforme/complicações , Manejo da Dor/métodos , Medição da Dor
6.
J Ultrasound Med ; 42(1): 135-145, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36165271

RESUMO

OBJECTIVES: We aimed to develop a standardized scoring tool to measure point-of-care ultrasound (POCUS) image quality and to determine validity evidence for its use to assess lung ultrasound image quality. METHODS: The POCUS Image Quality (POCUS IQ) scale was developed by POCUS-trained physicians to assess sonographers' image acquisition skills by evaluating image quality for any POCUS application. The scale was piloted using lung images of healthy standardized patients acquired by three expert sonographers compared to three novices before and after training. All images (experts, novices pre-training, novices post-training) were scored on the POCUS IQ scale by three blinded POCUS-trained physicians. Reliability was assessed with fully-crossed generalizability and decision studies. Validity was assessed using Messick's framework. RESULTS: Content validity was supported by the tool's development process of literature review, expert consensus, and pilot testing. Response process was supported by reviewer training and the blinded scoring process. Relation to other variables was supported by scores relating to sonographer experience: median expert score = 10.5/14 (IQR: 4), median novice pre-training score = 6/14 (IQR: 2.25), and novices' improvement after training (median post-training score = 12/14, IQR: 3.25). Internal structure was supported by internal consistency data (coefficient alpha = 0.84, omega coefficient = 0.91) and the generalizability study showing the main contributor to score variability was the sonographer (51%). The G-coefficient was 0.89, suggesting very good internal structure, however, Gwet's AC2  was 0.5, indicating moderate interrater reliability. The D study projected a minimum of 1 reviewer and 2 patients are needed for good psychometric reliability. CONCLUSIONS: The POCUS scale has good preliminary validity evidence as an assessment tool for lung POCUS image acquisition skills. Further studies are needed to demonstrate its utility for other POCUS applications and as a feedback tool for POCUS learners.


Assuntos
Médicos , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Reprodutibilidade dos Testes , Ultrassonografia/métodos , Testes Imediatos
7.
Pediatr Emerg Care ; 39(11): 892-894, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37815310

RESUMO

ABSTRACT: This case report describes a previously healthy pediatric patient with acute onset of abdominal pain and distention who was found to have an epigastric mass on physical examination. Point-of-care ultrasound (POCUS) demonstrated a large gastric mass with ultrasonographic features consistent with a trichobezoar. After POCUS was performed, trichophagia was confirmed on history, and the patient went to the operating room for removal of a large trichobezoar. We conclude POCUS may be helpful for evaluation of epigastric masses and diagnosis of gastric trichobezoars. We review the ultrasound technique, sonographic findings, and literature regarding ultrasound diagnosis of trichobezoars.


Assuntos
Bezoares , Humanos , Criança , Bezoares/diagnóstico por imagem , Bezoares/cirurgia , Sistemas Automatizados de Assistência Junto ao Leito , Testes Imediatos , Exame Físico , Ultrassonografia
8.
Pediatr Emerg Care ; 39(6): 438-442, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-36730897

RESUMO

OBJECTIVE: The aim of this study was to validate an adult-derived clinical decision rule for ultrasound identification of methicillin-resistant Staphylococcus aureus (MRSA) skin abscesses in a pediatric cohort. METHODS: We conducted a retrospective study of skin and soft tissue infections in patients <21 years presenting to the emergency department who had radiology performed ultrasounds completed and wound cultures obtained. Ultrasound scans were reviewed for edge definition, volume, and shape by 2 pediatric emergency physicians with expertise in point-of-care ultrasound, with approximately 25% of scans reviewed by both experts to evaluate interrater reliability. A third, blinded expert weighed in for discrepancies before analysis. Test performance characteristics were calculated for the clinical decision rule in children. RESULTS: Two hundred nine patients were enrolled, with mean age of 9.8 (±6.7) years; 87 (42%) were male. Sixty-nine (33%) patients had a wound culture positive for MRSA. The clinical decision rule had a sensitivity of 86% (95% confidence interval [CI], 75%-93%), specificity of 32% (95% CI, 25%-41%), positive predictive value of 38% (95% CI, 35%-42%), negative predictive value of 82% (95% CI, 71%-89%), positive likelihood ratio of 1.26 (95% CI, 1.08-1.46), negative likelihood ratio of 0.45 (95% CI, 0.24-0.84), and an odds ratio of 2.8 (95% CI, 1.31-5.97). CONCLUSIONS: This clinical decision rule for ultrasound identification of MRSA abscesses had moderately high sensitivity and negative predictive value in pediatric patients, with similar sensitivity compared with the original adult validation group. Ultrasound may help identify MRSA abscesses, allowing for improved antibiotic choices and outcomes for children with MRSA abscesses.


Assuntos
Staphylococcus aureus Resistente à Meticilina , Infecções Estafilocócicas , Infecções Cutâneas Estafilocócicas , Adulto , Criança , Humanos , Masculino , Feminino , Infecções Cutâneas Estafilocócicas/diagnóstico por imagem , Estudos Retrospectivos , Abscesso/diagnóstico por imagem , Reprodutibilidade dos Testes , Regras de Decisão Clínica , Antibacterianos
9.
J Ultrasound Med ; 41(5): 1179-1186, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34387396

RESUMO

OBJECTIVES: To determine if point-of-care ultrasound (POCUS) of ankle injuries in children, in conjunction with validated ankle injury clinical prediction rules, can accurately diagnose ankle fracture in children. METHODS: A prospective observational study was conducted on patients (birth-21 years) presenting to a pediatric emergency department with an ankle injury requiring ankle radiograph. POCUS of the injured ankle was performed to evaluate for fracture. Clinical prediction rule scores (Ottawa Ankle and Low Risk Ankle) were recorded along with pre- and post-ultrasound clinical suspicion for fracture. Diagnosis of ankle fracture was confirmed via radiology radiograph report. Test characteristics of sensitivity, specificity, positive and negative predictive values were calculated. RESULTS: Forty-eight patients were enrolled, 58% were female, with a mean age of 12.2 years (SD 3.8). Twelve (25%) patients had ankle POCUS positive or indeterminate for fracture. Nine (19%) patients had fracture based on radiograph, and 6 of the 9 (67%) patients with fracture had open growth plates. Ankle POCUS was found to have a sensitivity of 56% (95% confidence interval [CI], 23-85%), specificity of 82% (95% CI, 66-92%), positive predictive value of 42% (95% CI, 17-71%), and negative predictive value of 89% (95% CI, 73-96%). CONCLUSIONS: Our findings suggest that ankle POCUS in children is a difficult application to perform and interpret compared with radiographic diagnosis of fracture. Open growth plates may complicate accurate identification of fracture using POCUS and at this time serves as a poor screening exam to assess for fracture or the need for radiographs.


Assuntos
Fraturas do Tornozelo , Traumatismos do Tornozelo , Traumatismos do Tornozelo/diagnóstico por imagem , Criança , Serviço Hospitalar de Emergência , Feminino , Humanos , Masculino , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade , Ultrassonografia
10.
Pediatr Emerg Care ; 38(2): e1025-e1027, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34140449

RESUMO

ABSTRACT: Point-of-care musculoskeletal ultrasound can facilitate diagnosis of joint effusions and help guide management of suspected septic joints. This case report describes a previously healthy pediatric patient with acute onset shoulder pain and fever who was found to have leukocytosis and bacteremia. Point-of-care ultrasound (POCUS) demonstrated a unilateral shoulder joint effusion. After POCUS was performed, purulent fluid was aspirated from the joint, and she was diagnosed with a septic shoulder. We review the ultrasound technique, sonographic findings, and literature regarding POCUS for shoulder effusions.


Assuntos
Artrite Infecciosa , Articulação do Ombro , Artrite Infecciosa/complicações , Artrite Infecciosa/diagnóstico por imagem , Criança , Feminino , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Ombro , Articulação do Ombro/diagnóstico por imagem , Ultrassonografia
11.
Pediatr Emerg Care ; 38(1): e17-e22, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34986583

RESUMO

OBJECTIVES: The aim of the study was to determine whether point-of-care ultrasound (US) can decrease x-rays in children with ankle injuries. Secondary objectives were to determine the test performance characteristics for ankle US, analyze diagnostic errors, and compare US with the Ottawa Ankle Rules (OAR). METHODS: This was a prospective study of children younger than 21 years presenting to an emergency department with an ankle injury requiring x-rays. Pediatric emergency medicine physicians received a 1-hour training session, performed ankle US with a standardized scanning protocol of the distal tibia and fibula, and described the US as positive, negative, or equivocal for fracture. Ankle x-ray interpretation by a radiologist was the reference standard for fracture. RESULTS: One hundred twenty patients with a mean age of 13.5 (±4.0) years were enrolled. Nine patients (7.5%) had an ankle fracture on x-ray, and 56 patients (47%) had open physes. Ankle US would reduce x-rays by 81 (67.5%), missing 2 intra-articular, nondisplaced, tibial fractures in patients with open physes. Ankle US had a sensitivity of 78% (95% confidence interval [CI], 40%-97%), specificity of 71% (95% CI, 62%-79%), likelihood ratio for a positive test of 2.7 (95% CI, 1.7-4.3), and likelihood ratio for a negative test of 0.31 (95% CI, 0.09-1.07). The OAR would reduce x-rays by 21 (17.5%), missing one fracture. Ultrasound with OAR would reduce x-rays by 20 (17%) with no missed fractures. CONCLUSIONS: Point-of-care US has the potential to reduce x-rays for children with ankle injuries; however, nondisplaced, intra-articular tibial fractures may be missed. Ultrasound with OAR may reduce radiographs without missed fractures in this population.


Assuntos
Traumatismos do Tornozelo , Fraturas Ósseas , Fraturas da Tíbia , Adolescente , Traumatismos do Tornozelo/diagnóstico por imagem , Criança , Serviço Hospitalar de Emergência , Fraturas Ósseas/diagnóstico por imagem , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos , Sensibilidade e Especificidade , Ultrassonografia
12.
Pediatr Emerg Care ; 37(6): 334-339, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33871226

RESUMO

OBJECTIVES: Multisystem inflammatory syndrome in children (MIS-C) associated with coronavirus disease 2019 is a novel pediatric condition with significant morbidity and mortality. The primary objective of this investigation was to describe the point-of-care ultrasound (POCUS) findings in patients evaluated in the emergency department (ED) who were diagnosed with MIS-C. METHODS: A retrospective cross-sectional study was conducted including patients <21-years-old who had POCUS performed for clinical care in a pediatric ED and were diagnosed with MIS-C. Point-of-care ultrasound studies were performed by pediatric emergency medicine attending physicians or fellows. Data abstracted by chart review included patient demographics, clinical history, physical examination findings, diagnostic test results, the time POCUS studies and echocardiograms were performed, therapies administered, and clinical course after admission. RESULTS: For the 24 patients included, 17 focused cardiac ultrasound, 9 lung POCUS, 7 pediatric modified rapid ultrasound for shock and hypotension, 1 focused assessment with sonography for trauma, 1 POCUS for suspected appendicitis, and 1 ocular POCUS were performed by 13 physicians. Point-of-care ultrasound identified impaired cardiac contractility in 5 patients, large intraperitoneal free fluid with inflamed bowel in 1 patient, and increased optic nerve sheath diameters with elevation of the optic discs in 1 patient. Trace or small pericardial effusions, pleural effusions, and intraperitoneal free fluid were seen in 3 patients, 6 patients, and 4 patients, respectively. CONCLUSIONS: This study demonstrates the spectrum of POCUS findings in MIS-C. Prospective studies are needed to help delineate the utility of incorporating POCUS into an ED management pathway for patients with suspected MIS-C.


Assuntos
COVID-19/diagnóstico por imagem , COVID-19/fisiopatologia , Testes Imediatos , Síndrome de Resposta Inflamatória Sistêmica/diagnóstico por imagem , Síndrome de Resposta Inflamatória Sistêmica/fisiopatologia , Adolescente , Adulto , COVID-19/complicações , Criança , Pré-Escolar , Estudos Transversais , Serviço Hospitalar de Emergência , Feminino , Hospitais Pediátricos , Humanos , Masculino , Estudos Retrospectivos , SARS-CoV-2 , Síndrome de Resposta Inflamatória Sistêmica/complicações , Ultrassonografia , Adulto Jovem
13.
J Emerg Med ; 58(3): 457-463, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31843323

RESUMO

BACKGROUND: Point-of-care ultrasound (POCUS) is commonly used to facilitate care in the emergency department. Acquired images are often reviewed by local experts for educational and quality assurance purposes. However, no published study has examined the accuracy and reliability of POCUS image interpretation by multiple reviewers. OBJECTIVES: We studied the accuracy and interrater agreement among expert and trainee reviewers of prerecorded pediatric skin and soft tissue (SST) POCUS images. METHODS: POCUS faculty and emergency medicine (EM) residents blindly reviewed deidentified pediatric SST POCUS images and indicated whether a drainable fluid collection was present, absent, or indeterminate. This was then compared with the gold standard based on discharge diagnoses and telephone follow-up. Images rated as indeterminate were excluded from the initial analysis. Sensitivity analysis assuming indeterminate answers were inaccurate was subsequently conducted. RESULTS: In phase 1, 6 pediatric EM POCUS directors reviewed 168 images. The overall accuracy was 79.7% (range 66.1-86.0%). The mean Cohen's kappa was 0.58 (range 0.24-0.84). Sensitivity analysis yielded an overall accuracy of 71.3% (range 56.5-76.9%) and a Cohen's kappa of 0.43 (range 0.20-0.59). In phase 2, 6 general EM POCUS faculty and 20 EM residents reviewed 120 images. The overall accuracy among residents was 72.2% (range 51.4-84.7%) and among faculty was 83.6% (range 77.9-88.8%). Sensitivity analysis yielded an overall resident accuracy of 63.0% (range 49.5-80.7) and an overall faculty accuracy of 73.9% (range 67.0-79.8%). Fleiss' kappa was 0.322 for residents and 0.461 for faculty. CONCLUSIONS: We found moderate accuracy and fair to good interrater agreement among POCUS faculty and EM residents reviewing pediatric SST POCUS images.


Assuntos
Medicina de Emergência , Sistemas Automatizados de Assistência Junto ao Leito , Pele/diagnóstico por imagem , Ultrassonografia , Criança , Serviço Hospitalar de Emergência , Docentes , Humanos , Reprodutibilidade dos Testes
14.
Pediatr Emerg Care ; 36(11): 544-548, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32925701

RESUMO

Lung point-of-care ultrasound (POCUS) has been shown to be useful for identifying pulmonary pathology in adult patients with coronavirus disease 2019 (COVID-19). However, pediatric literature for POCUS in COVID-19 is limited. The objective of this case series was to describe lung POCUS findings in pediatric patients with COVID-19. Three patients with COVID-19 who had lung POCUS performed in a pediatric emergency department were included. Point-of-care ultrasound revealed bilateral abnormalities in all patients, including pleural line irregularities, scattered and coalescing B-lines, consolidations, and pleural effusions. Additional pediatric studies are necessary to gain a broader understanding of COVID-19's sonographic appearance in this age group and to determine whether POCUS may be helpful to facilitate diagnosis and expedite management decisions.


Assuntos
Betacoronavirus , Infecções por Coronavirus/diagnóstico , Serviço Hospitalar de Emergência , Pulmão/diagnóstico por imagem , Pandemias , Pneumonia Viral/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , Ultrassonografia/métodos , COVID-19 , Criança , Infecções por Coronavirus/epidemiologia , Feminino , Humanos , Masculino , Pneumonia Viral/epidemiologia , SARS-CoV-2 , Adulto Jovem
15.
Am J Emerg Med ; 37(9): 1746-1750, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31257125

RESUMO

BACKGROUND: Identification of intussusception is feasible with emergency department (ED) point-of-care ultrasound (PoCUS) due to its ease-of-use and high accuracy. Little is known about the clinical characteristics and outcomes of small bowel-small bowel intussusception (SB-SBI) relative to ileocolic intussusception (ICI) identified by PoCUS. METHODS: We conducted a retrospective cohort study at a single, tertiary care, urban pediatric ED of intussusception identified by PoCUS. Demographic information, clinical data, and outcomes, including clinical course, intussusception characteristics, recurrence rates, and interobserver agreement (Cohen's kappa), were evaluated. RESULTS: ED PoCUS identified thirty-seven patients with intussusception over a 4-year period. Twenty-one patients (57%) identified were SB-SBI. The median age was 54 months (IQR 35-76 months) for SB-SBI and 8 months (IQR 5.8-13.5 months) for ICI. The mean diameter was 1.68 cm (SD 0.52 cm) for SB-SBI and 2.74 cm (SD 0.43 cm) for ICI (p < 0.05). Two of 21 (9.5%) SB-SBI subjects required surgical intervention, while the rest spontaneously reduced. Fourteen of 16 (88%) ICI subjects required intervention. There were two (9.5%) recurrences of SB-SBI and 1 (6.3%) recurrence of ICI confirmed on PoCUS. Cohen's kappa was 0.85 (95% CI 0.68-1.0). CONCLUSIONS: SB-SBI may be identified more frequently than previously thought when screened with ED PoCUS. Older children with SB-SBI may have underlying lead-points and may require surgical intervention. PoCUS can help differentiate between variants of intussusception that range from a surgical emergency to a transient source of abdominal pain that may be recurrent and otherwise unexplained, allowing clinicians to better manage these patients accordingly.


Assuntos
Doenças do Íleo/diagnóstico , Intestino Delgado/diagnóstico por imagem , Intussuscepção/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito/estatística & dados numéricos , Ultrassonografia/métodos , Adolescente , Criança , Pré-Escolar , Serviço Hospitalar de Emergência , Feminino , Humanos , Doenças do Íleo/patologia , Lactente , Intestino Delgado/patologia , Intussuscepção/classificação , Intussuscepção/patologia , Masculino , Estudos Retrospectivos
16.
J Pediatr ; 198: 214-219.e2, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29681446

RESUMO

OBJECTIVES: To determine whether point-of-care elbow ultrasound (US), with history and physical examination, can decrease radiography for patients with elbow trauma. Secondary outcomes included evaluation of pediatric emergency department (PED) length of stay (LOS) and test performance characteristics. STUDY DESIGN: This was a prospective study of patients up to age 21 years with elbow trauma necessitating radiography. After clinical examination and before radiography, pediatric emergency physicians performed elbow ultrasonography of the posterior fat pad and determined whether radiography was required. All patients underwent elbow radiography and received clinical follow-up. Times for US and radiography were recorded. RESULTS: A total of 100 patients with a mean age of 7.9 years were enrolled, 42 of whom had a fracture. In 23 patients, the physician determined that radiography could be eliminated. Elbow US combined with clinical suspicion for fracture had a sensitivity of 100% (95% CI, 92%-100%). Elbow US took a median of 3 minutes (IQR, 2-5 minutes), and completion and interpretation of elbow radiography took a median of 60 minutes (IQR, 43-84 minutes). The overall sensitivity of elbow US was 88% (95% CI, 75%-96%). CONCLUSIONS: Elbow US has a high sensitivity to rule out fracture and is best used in patients with a low clinical suspicion of fracture. The use of conventional radiography and PED LOS may be reduced in patients with a low clinical concern for fracture and normal elbow US.


Assuntos
Traumatismos do Braço/diagnóstico por imagem , Lesões no Cotovelo , Cotovelo/diagnóstico por imagem , Sistemas Automatizados de Assistência Junto ao Leito , Radiografia , Ultrassonografia , Adolescente , Criança , Pré-Escolar , Serviço Hospitalar de Emergência , Feminino , Fraturas Ósseas/diagnóstico por imagem , Humanos , Tempo de Internação , Masculino , Estudos Prospectivos , Sensibilidade e Especificidade , Adulto Jovem
17.
J Emerg Med ; 55(5): 693-701, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30170835

RESUMO

BACKGROUND: Point-of-care ultrasound (POCUS) can potentially help distinguish cellulitis from abscess, which can appear very similar on physical examination but necessitate different treatment approaches. OBJECTIVE: To compare POCUS guidance vs. clinical assessment alone on the management of pediatric skin and soft tissue infections (SSTI) in the emergency department (ED) setting. METHODS: Children ages 6 months to 18 years presenting to participating EDs with SSTIs ≥ 1 cm were eligible. All treatment decisions, including use of POCUS, were at the discretion of the treating clinicians. Patients were divided into those managed with POCUS guidance (POCUS group) and those managed using clinical assessment alone (non-POCUS group). Primary outcome was clinical treatment failure at 7-10 days (unscheduled ED return visit or admission, procedural intervention, change in antibiotics therapy). Secondary outcomes were ED length of stay, discharge rate, use of alternative imaging, and need for procedural sedation. POCUS utility and impact on management decisions were also assessed by treating clinicians. RESULTS: In total, 321 subjects (327 lesions) were analyzed, of which 299 (93%) had completed follow-up. There was no significant difference between the POCUS and non-POCUS groups in any of the primary or secondary outcomes. Management plan was changed in the POCUS group in 22.9% of cases (13.8% from medical to surgical, 9.1% from surgical to medical). Clinicians reported increased benefit of POCUS in cases of higher clinical uncertainty. CONCLUSIONS: Use of POCUS was not associated with decreased ED treatment failure rate or process outcomes in pediatric SSTI patients. However, POCUS changed the management plan in approximately one in four cases.


Assuntos
Serviço Hospitalar de Emergência , Infecções dos Tecidos Moles/diagnóstico por imagem , Infecções dos Tecidos Moles/terapia , Ultrassonografia/métodos , Adolescente , Criança , Pré-Escolar , Diagnóstico Diferencial , Feminino , Humanos , Lactente , Masculino , Exame Físico , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos
18.
Pediatr Emerg Care ; 34(9): 673-675, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30180103

RESUMO

Point-of-care musculoskeletal ultrasound can provide information about joint effusions and the quality of the effusion. This case report describes the findings of a previously healthy pediatric patient with acute onset of knee swelling and abnormal gait. After point-of-care ultrasound demonstrated bilateral knee effusions with complex, heterogeneous material, subsequent workup revealed a diagnosis of juvenile idiopathic arthritis (JIA). We review the ultrasound technique, sonographic findings, and literature regarding point-of-care ultrasound for knee effusions and JIA.


Assuntos
Artrite Juvenil/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Sistemas Automatizados de Assistência Junto ao Leito , Ultrassonografia/métodos , Pré-Escolar , Diagnóstico Diferencial , Edema/etiologia , Feminino , Humanos
19.
Pediatr Emerg Care ; 32(9): 581-4, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26466149

RESUMO

OBJECTIVES: The primary objective of the study was to compare analgesia-prescribing practices and timing of analgesia administration between pediatric emergency medicine (PEM) and general emergency medicine (GEM) practitioners for children with appendicitis. The secondary objective was to compare analgesia administration versus triage pain score, pediatric appendicitis score (PAS), and body mass index (BMI). METHODS: This was a retrospective chart review of patients younger than 21 years who presented to either an urban pediatric emergency department (ED) or 2 general EDs and were diagnosed with appendicitis. RESULTS: Two hundred eighteen charts were reviewed, 153 (70%) from the pediatric ED and 65 (30%) from the general EDs. The patients seen by PEM physicians were younger than the patients seen by GEM physicians (mean age, 12.8 vs 15.4 years; P = 0.002). The patients evaluated by GEM physicians were more likely to receive analgesia in the ED (82% vs 60%, P = 0.003) and received analgesia sooner (mean, 178 vs 239 minutes; P = 0.026) than the patients evaluated by PEM physicians. The patients with triage pain scores higher than 6 of 10 were more likely to receive analgesia than the patients with pain scores lower than 6 (71% vs 51%, P = 0.015). There was no association between PAS or BMI and analgesia administration or time to analgesia (P = not significant). CONCLUSIONS: The patients with appendicitis evaluated by GEM physicians were more likely to receive analgesia and receive analgesia quicker than the patients evaluated by PEM physicians. The patients with higher pain scores were more likely to receive analgesia, but PAS and BMI did not affect analgesia administration.


Assuntos
Analgesia/métodos , Analgésicos/administração & dosagem , Apendicite/tratamento farmacológico , Medicina de Emergência , Dor/tratamento farmacológico , Padrões de Prática Médica/estatística & dados numéricos , Adolescente , Analgesia/estatística & dados numéricos , Criança , Feminino , Humanos , Masculino , Manejo da Dor , Pediatria , Estudos Retrospectivos , Fatores de Tempo , Triagem
20.
Pediatr Emerg Care ; 31(5): 327-30, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25875991

RESUMO

OBJECTIVE: The aim of this study was to determine whether elbow ultrasound findings of the posterior fat pad (PFP) are present in patients with diagnosis of radial head subluxation (RHS). METHODS: This was a prospective study of children presenting to an urban pediatric emergency department diagnosed clinically with RHS. Physicians received a 1-hour training session on musculoskeletal ultrasound including the elbow. Before performing reduction for RHS, the physicians performed a brief, point-of-care elbow ultrasound using a high-frequency linear transducer probe in both longitudinal and transverse views to evaluate for PFP elevation and lipohemarthrosis (LH). Successful clinical reduction with spontaneous movement of injured extremity served as the criterion standard for RHS. Clinical telephone follow-up was performed to ascertain outcomes. RESULTS: Forty-two patients were enrolled with a mean age of 22.3 (11.8) months. The mean time to presentation was 7 (9.2) hours, and 9/42 (21%) children had previous history of RHS. The majority of patients (35/42, 83%; 95% confidence interval (CI), 69%-92%) had a normal elbow ultrasound. Of 42 patients, 6 (14%; 95% CI 6%-28%) had an elevated PFP and 2 (5%; 95% CI, 0.5%-17%) had LH. Clinical reduction was successful in 100% of patients, and there were no complications reported on follow-up. CONCLUSIONS: The majority of children with RHS have a normal PFP on elbow ultrasound, but elevated PFP and LH are possible findings. Reduction maneuvers for RHS may be attempted in patients with a normal elbow ultrasound when the diagnosis of RHS or elbow fracture is uncertain.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Mau Alinhamento Ósseo/diagnóstico por imagem , Cotovelo/diagnóstico por imagem , Rádio (Anatomia)/anormalidades , Rádio (Anatomia)/diagnóstico por imagem , Tecido Adiposo/anatomia & histologia , Tecido Adiposo/patologia , Mau Alinhamento Ósseo/terapia , Pré-Escolar , Cotovelo/patologia , Serviço Hospitalar de Emergência , Feminino , Seguimentos , Humanos , Lactente , Masculino , Procedimentos Ortopédicos/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos , Rádio (Anatomia)/patologia , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA