RESUMO

BACKGROUND: To identify and summarize the global research literature on validation of automated noninvasive blood pressure measurement devices (BPMDs) with upper arm cuff, develop a repository of validated BPMDs in compliance with the 2020 World Health Organization technical specifications, and identify challenges and gaps in evidence base on validated BPMDs. METHODS: A scoping review was conducted. Primary research validating BPMDs complying with the 2020 World Health Organization technical specifications (ie, semiautomated/automated noninvasive devices with upper arm cuff), published in English between January 2000 and December 2021, was included. We searched MEDLINE, Web of Science, Scopus, EMBASE, CINAHL, CENTRAL, ProQuest and the dabl website. RESULTS: We included 269 studies validating 251 BPMDs across 89 manufacturers. Omron (29%), Microlife (10%), and A&D Company (8%) were the top 3 manufacturers. The 3 most frequently used validation protocols were the European Society of Hypertension-international protocol 2002 (27%), European Society of Hypertension-international protocol 2010 (25%), and modified British Hypertension Society protocol 1993 (16%), respectively. Nearly 45% of the validated BPMDs were intended for use in clinical settings, 38% were for home or self-measurement use, and 48% were for general adults. Most studies reported that BPMDs passed the validation criteria. There was inadequate reporting across studies, especially pertaining to validation settings. CONCLUSIONS: Most BPMDs fulfilled the validation criteria. However, there are considerable gaps in BPMD research in terms of geographical representation, including specific target populations and diseases/conditions, and a range of arm circumferences. Additionally, a potential strategy is required to accelerate the adoption of the Association for the Advancement of Medical Instrumentation (AAMI)/European Society of Hypertension/International Organization for Standardization Universal Standard (International Organization for Standardization 81060-2:2018) for BPMD validation.


Assuntos
Determinação da Pressão Arterial , Hipertensão , Adulto , Humanos , Pressão Sanguínea , Determinação da Pressão Arterial/métodos , Esfigmomanômetros , Organização Mundial da Saúde , Monitores de Pressão Arterial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA