Bilateral simultaneous middle cerebral artery occlusion is a rare condition that may lead to severe neurological disability or death, thus requiring rapid intervention in order to restore vessels patency and brain perfusion. Perfusion-computed tomography is demonstrated to be a fundamental tool for selecting stroke patients candidate to mechanical thrombectomy, but its role for guiding the optimal strategy of endovascular treatment in concomitant multivessel cerebral occlusion has never been reported. We describe a case of bilateral middle cerebral artery occlusion in which perfusion-computed tomography was crucial both for addressing to endovascular procedure and planning the sequence treatment of mechanical thrombectomies.


Assuntos
Procedimentos Endovasculares , Infarto da Artéria Cerebral Média , Acidente Vascular Cerebral , Angiografia Digital , Angiografia Cerebral , Humanos , Infarto da Artéria Cerebral Média/diagnóstico por imagem , Artéria Cerebral Média/diagnóstico por imagem , Artéria Cerebral Média/cirurgia , Perfusão , Trombectomia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
2.
Ann Vasc Surg ; 44: 119-127, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28479464

RESUMO

BACKGROUND: Intraprocedural aneurysm sac embolization (embo-EVAR) during endovascular abdominal aneurysm repair (EVAR) using coils and fibrin glue is a technique for preventing type II endoleak (EII). Our aim is to evaluate feasibility, safety and clinical outcome of this promising approach. MATERIALS AND METHODS: A retrospective clinical case analysis of 72 patients who underwent EVAR during the period 2011-2014. Two groups were compared at 6 and 12 months follow-up with contrast media computed tomography scan and contrast-enhanced ultrasound (CEUS) imaging: consecutively, 36 patients (group A) treated with classic EVAR and 36 patients (group B) treated with embo-EVAR. Coils were released filling better as possible the aneurysm sac; the embolization was completed by injecting fibrin glue. Device and materials used, differential systemic and sac pressures, presence of any endoleak, and complication were registered. RESULTS: In our experience, we had 100% technical success without surgical conversion. Embo-EVAR was performed, after endograft deployment, in group B patients, all with ratio of Δ-pressures (obtained from Δ-sac pressure/Δ-differential pressure) > 0.16. No early or late complications occurred and mortality was nil. Follow-up was performed with computed tomography-angiography and CEUS at 6 and 12 months. We observed 9 type II and 1 type Ia endoleak in group A and 2 type II and 1 type Ib endoleaks in group B. Mean radiation exposure time was 30.3 min in group A and 43.3 min in group B. EVAR procedure average cost was 9,000 €. The average cost of sac embolization was 1,500€. CONCLUSIONS: Although a randomized study is necessary, embo-EVAR may be a valid approach to prevent type II endoleaks and further complications. Mild costs and exposure-dose increase could be accepted to avoid reinterventions, and in our experience, it could be routinely performed with excellent results.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/métodos , Embolização Terapêutica , Endoleak/prevenção & controle , Procedimentos Endovasculares/métodos , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/economia , Aneurisma da Aorta Abdominal/mortalidade , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/economia , Implante de Prótese Vascular/mortalidade , Angiografia por Tomografia Computadorizada , Meios de Contraste/administração & dosagem , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/economia , Embolização Terapêutica/mortalidade , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/economia , Procedimentos Endovasculares/mortalidade , Estudos de Viabilidade , Feminino , Custos Hospitalares , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Exposição à Radiação , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia
3.
Abdom Imaging ; 40(1): 46-55, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24965896

RESUMO

PURPOSE: To evaluate Gd-EOB-DTPA-enhanced magnetic resonance (MR) performance during dynamic (DYN) phases, hepatobiliary (HB) phase and diffusion-weighted imaging (DWI) compared with pathological findings in patients undergoing orthotopic liver transplantation (OLT) for hepatocellular carcinoma (HCC) associated with different conditions, such as stage of chronic liver disease, histological grading, nodule size, and occurrence of previous treatments. METHODS: Retrospective analysis of 64 nodules reported as HCC at pathological analysis on 28 explanted livers, examined about 3 months before OLT using a 1.5 T device and 16 channels array after intravenous GD-EOB-DTPA injection. Lesions features and hepatic functional values were recorded for each patient. Two radiologists performed in consensus the analysis of nodules on DYN, HB, and DWI. MR findings were compared with those of pathological anatomy. Diagnostic indicators were calculated for each technique. RESULTS: DYN and HB showed no statistically significant difference in sensitivity (88% and 98%, respectively), diagnostic accuracy (90.6% and 99.9%), and specificity (both 100%), for all Child-Pugh scores, gradings, sizes, and presence or absence of previous treatments. DWI had a statistically significant lower sensitivity compared to DYN (p = 0.001) and HB (p < 0.0001); its sensitivity was significantly inferior for Child-Pugh Class B nodules than for Child-Pugh Class A ones (p = 0.00005). DWI sensitivity presented a significant increase (p = 0.03) with grading and presence of previous treatments (p = 0.0006). ADC values showed no statistically significant changes with Child-Pugh score, grading and nodules size; statistically significant increase was instead found for treated vs. untreated nodules (p = 0.016). CONCLUSIONS: In a multiparametric HCC MRI assessment, DYN and HB play the leading role, with DWI faring acceptably well for Child-Pugh Class A nodules and treated ones.


Assuntos
Carcinoma Hepatocelular/patologia , Gadolínio DTPA , Neoplasias Hepáticas/patologia , Transplante de Fígado , Imageamento por Ressonância Magnética , Adulto , Idoso , Meios de Contraste , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Aumento da Imagem , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Período Pós-Operatório , Período Pré-Operatório , Estudos Retrospectivos , Sensibilidade e Especificidade
4.
J Cardiovasc Magn Reson ; 16: 41, 2014 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-24927953

RESUMO

BACKGROUND: Atrio-oesophageal fistula was first reported as a fatal complication of surgical endocardial and percutaneous endocardial radiofrequency ablation for atrial fibrillation, with an incidence after catheter ablation between 0.03% and 0.5%. Magnetic resonance angiography (MRA) was usually performed to obtain pre-procedural 3D images, used to merging into an electro-anatomical map, guiding step-by-step ablation strategy of AF. Our aim was to find an easy, safe and cost-effective way to enhance the oesophagus during MRA. METHODS: In 105 consecutive patients, a right-left phase encoding, free breathing, 3D T1 MRA sequence was performed in the axial plane, >24 hours before catheter ablation, using an intravenous injection of gadobenate dimeglumine contrast medium. The oesophagus was enhanced using an oral gel solution of 0.7 mL gadobenate dimeglumine contrast medium mixed with approximately 40 mg thickened water gel, which was swallowed by the patients on the scanning table, immediately before the MRA sequence acquisition. RESULTS: The visualisation of the oesophagus was obtained in 104/105 patients and images were successfully merged, as left atrium and pulmonary veins, into an electro-anatomical map, during percutaneous endocardial radiofrequency ablation. All patients tolerated the study protocol and no immediate or late complication was observed with the oral contrast agent administration. The free-breathing MRA sequence used in our protocol took 7 seconds longer than MRA breath-hold conventional sequence. CONCLUSION: Oesophagus visualization with oral gadobenate dimeglumine is feasible for integration of oesophagus anatomy images into the electro-anatomical map during AF ablation, without undesirable side effects and without significantly increasing cost or examination time.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter , Meios de Contraste/administração & dosagem , Esôfago/anatomia & histologia , Angiografia por Ressonância Magnética , Meglumina/análogos & derivados , Compostos Organometálicos/administração & dosagem , Administração Oral , Adulto , Idoso , Pontos de Referência Anatômicos , Fibrilação Atrial/patologia , Fístula Esofágica/etiologia , Fístula Esofágica/prevenção & controle , Estudos de Viabilidade , Feminino , Humanos , Injeções Intravenosas , Masculino , Meglumina/administração & dosagem , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Resultado do Tratamento
5.
CVIR Endovasc ; 4(1): 25, 2021 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-33655366

RESUMO

BACKGROUND: Ovarian vein embolization in pelvic varicocele is usually obtained using nitinol coils. These devices can not be used in patients with proven nickel allergy. CASE PRESENTATION: Shape memory polymer is a new embolic material available to interventionalists. A patient presented with pelvic congestion syndrome requiring embolisation of the left ovarian vein. The target vessel consisted of two twisted branches, each 5-6 mm in diameter. The patient also had a known allergy to nickel. Considering the anatomy and allergy status, embolisation with polyurethane shape memory polymer vascular plugs was considered a good case strategy. The embolisation procedure was technically successful with the deployment of two shape memory polymer plugs into each of the two left ovarian vein branches. Follow-up magnetic resonance imaging at 4 months showed sustained occlusion of the treated vessels and the patient showed no signs of allergy to the implanted material. CONCLUSIONS: In conclusion, our case presented an opportunity to utilise a new embolic material and achieve a good outcome in a patient with an allergy that may have resulted in complications when using metallic implants.