Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Exp Eye Res ; 234: 109602, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37488007

RESUMO

Glaucoma is the leading cause of irreversible blindness worldwide and its most prevalent subtype is primary open angle glaucoma (POAG). One pathological change in POAG is loss of cells in the trabecular meshwork (TM), which is thought to contribute to ocular hypertension and has thus motivated development of cell-based therapies to refunctionalize the TM. TM cell therapy has shown promise in intraocular pressure (IOP) control, but existing cell delivery techniques suffer from poor delivery efficiency. We employed a novel magnetic delivery technique to reduce the unwanted side effects of off-target cell delivery. Mesenchymal stem cells (MSCs) were labeled with superparamagnetic iron oxide nanoparticles (SPIONs) and after intracameral injection were magnetically steered towards the TM using a focused magnetic apparatus ("point magnet"). This technique delivered the cells significantly closer to the TM at higher quantities and with more circumferential uniformity compared to either unlabeled cells or those delivered using a "ring magnet" technique. We conclude that our point magnet cell delivery technique can improve the efficiency of TM cell therapy and in doing so, potentially increase the therapeutic benefits and lower the risk of complications such as tumorigenicity and immunogenicity.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Animais , Camundongos , Malha Trabecular/patologia , Glaucoma de Ângulo Aberto/patologia , Glaucoma/patologia , Pressão Intraocular , Fenômenos Magnéticos
2.
Exp Eye Res ; 202: 108354, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33171192

RESUMO

Most animal models of glaucoma rely on induction of ocular hypertension (OHT), yet such models can suffer from high IOPs leading to undesirable retinal ischemia. Thus, animals with IOPs exceeding a threshold (e.g. > 60 mmHg) are often excluded from studies. However, due to the intermittent nature of IOP measurements, this approach may fail to detect ischemia. Conversely, it may also inappropriately eliminate animals with IOP spikes that do not induce ischemic damage. It is known that acute ischemia selectively impairs inner retinal function, which results in a reduced b-wave amplitude. Here, we explore the potential of using electroretinography (ERG) to detect ischemic damage in OHT eyes. 74 Brown Norway rats received a unilateral injection of magnetic microbeads to induce OHT, while contralateral eyes served as controls. IOP was measured every 2-3 days for 14 days after microbead injection. Retinal function was evaluated using dark-adapted bright flash ERG (2.1 log cd•s/m2) prior to, and at 7 and 14 days after, injection. We investigated two criteria for excluding animals: (IOP Criterion) a single IOP measurement > 60 mmHg; or (ERG Criterion) a b-wave amplitude below the 99.5% confidence interval for naïve eyes. 49 of 74 rats passed both criteria, 7 of 74 failed both, and 18 passed one criterion but not the other. We suggest that ERG testing can detect unwelcome ischemic damage in animal models of OHT. Since brief IOP spikes do not necessarily lead to ischemic retinal damage, and because extended periods of elevated IOP can be missed, such ERG-based criteria may provide more objective and robust exclusion criteria in future glaucoma studies.


Assuntos
Adaptação à Escuridão/fisiologia , Glaucoma/fisiopatologia , Pressão Intraocular/fisiologia , Isquemia/fisiopatologia , Células Ganglionares da Retina/patologia , Animais , Modelos Animais de Doenças , Eletrorretinografia , Glaucoma/complicações , Glaucoma/diagnóstico , Isquemia/diagnóstico , Isquemia/etiologia , Masculino , Ratos , Ratos Endogâmicos BN
3.
Exp Eye Res ; 185: 107689, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31175860

RESUMO

Spontaneous retinal venous pulsations (SRVPs), pulsations of branches of the central retinal vein, are affected by intraocular pressure (IOP) and intracranial pressure (ICP) and thus convey potentially-useful information about ICP. However, the exact relationship between SRVPs, IOP, and ICP is unknown. It is not easily feasible to study this relationship in humans, necessitating the use of an animal model. We here propose tree shrews as a suitable animal model to study the complex relationship between SRVPs, IOP, and ICP. Tree shrew SRVP incidence was determined in a population of animals. Following validation of a modified IOP control system to accurately and quickly control IOP, IOP and/or ICP were manipulated in two tree shrews with SRVPs and the effects on SRVP properties were quantified. SRVPs were present in 75% of tree shrews at physiologic IOP and ICP. Altering IOP or ICP produced changes in tree shrew SRVP properties; specifically, increasing IOP caused SRVP amplitude to increase, while increasing ICP caused SRVP amplitude to decrease. In addition, a higher IOP was necessary to generate SRVPs at a higher ICP than at a lower ICP. SRVPs occur with a similar incidence in tree shrews as in humans, and tree shrew SRVPs are affected by changes in IOP and ICP in a manner qualitatively similar to that reported in humans. In view of anatomic similarities, tree shrews are a promising animal model system to further study the complex relationship between SRVPs, IOP, and ICP.


Assuntos
Modelos Animais de Doenças , Hipertensão Intracraniana/fisiopatologia , Hipertensão Ocular/fisiopatologia , Fluxo Pulsátil/fisiologia , Veia Retiniana/fisiologia , Animais , Feminino , Humanos , Pressão Intracraniana/fisiologia , Pressão Intraocular/fisiologia , Masculino , Tomografia de Coerência Óptica , Tupaia , Gravação em Vídeo
4.
Exp Eye Res ; 158: 3-12, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27448987

RESUMO

Alterations in stiffness of the trabecular meshwork (TM) may play an important role in primary open-angle glaucoma (POAG), the second leading cause of blindness. Specifically, certain data suggest an association between elevated intraocular pressure (IOP) and increased TM stiffness; however, the underlying link between TM stiffness and IOP remains unclear and requires further study. We here first review the literature on TM stiffness measurements, encompassing various species and based on a number of measurement techniques, including direct approaches such as atomic force microscopy (AFM) and uniaxial tension tests, and indirect methods based on a beam deflection model. We also briefly review the effects of several factors that affect TM stiffness, including lysophospholipids, rho-kinase inhibitors, cytoskeletal disrupting agents, dexamethasone (DEX), transforming growth factor-ß2 (TGF-ß2), nitric oxide (NO) and cellular senescence. We then describe a method we have developed for determining TM stiffness measurement in mice using a cryosection/AFM-based approach, and present preliminary data on TM stiffness in C57BL/6J and CBA/J mouse strains. Finally, we investigate the relationship between TM stiffness and outflow facility between these two strains. The method we have developed shows promise for further direct measurements of mouse TM stiffness, which may be of value in understanding mechanistic relations between outflow facility and TM biomechanical properties.


Assuntos
Elasticidade/fisiologia , Glaucoma de Ângulo Aberto/fisiopatologia , Fenômenos Fisiológicos Oculares , Malha Trabecular/fisiopatologia , Animais , Humor Aquoso/metabolismo , Fenômenos Biomecânicos , Técnicas de Imagem por Elasticidade , Feminino , Humanos , Pressão Intraocular/fisiologia , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Endogâmicos CBA , Microscopia de Força Atômica
5.
Am J Physiol Cell Physiol ; 309(4): C205-14, 2015 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-26040898

RESUMO

Elevated intraocular pressure (IOP) is the main risk factor for glaucoma. Exogenous nitric oxide (NO) decreases IOP by increasing outflow facility, but whether endogenous NO production contributes to the physiological regulation of outflow facility is unclear. Outflow facility was measured by pressure-controlled perfusion in ex vivo eyes from C57BL/6 wild-type (WT) or transgenic mice expressing human endothelial NO synthase (eNOS) fused to green fluorescent protein (GFP) superimposed on the endogenously expressed murine eNOS (eNOS-GFPtg). In WT mice, exogenous NO delivered by 100 µM S-nitroso-N-acetylpenicillamine (SNAP) increased outflow facility by 62 ± 28% (SD) relative to control eyes perfused with the inactive SNAP analog N-acetyl-d-penicillamine (NAP; n = 5, P = 0.016). In contrast, in eyes from eNOS-GFPtg mice, SNAP had no effect on outflow facility relative to NAP (-9 ± 4%, P = 0.40). In WT mice, the nonselective NOS inhibitor N(G)-nitro-l-arginine methyl ester (l-NAME, 10 µM) decreased outflow facility by 36 ± 13% (n = 5 each, P = 0.012), but 100 µM l-NAME had no detectable effect on outflow facility (-16 ± 5%, P = 0.22). An eNOS-selective inhibitor (cavtratin, 50 µM) decreased outflow facility by 19 ± 12% in WT (P = 0.011) and 39 ± 25% in eNOS-GFPtg (P = 0.014) mice. In the conventional outflow pathway of eNOS-GFPtg mice, eNOS-GFP expression was localized to endothelial cells lining Schlemm's canal and the downstream vessels, with no apparent expression in the trabecular meshwork. These results suggest that endogenous NO production by eNOS within endothelial cells of Schlemm's canal or downstream vessels contributes to the physiological regulation of aqueous humor outflow facility in mice, representing a viable strategy to more successfully lower IOP in glaucoma.


Assuntos
Humor Aquoso/metabolismo , Glaucoma/metabolismo , Pressão Intraocular/fisiologia , Óxido Nítrico Sintase Tipo III/metabolismo , Óxido Nítrico/fisiologia , Animais , Feminino , Humanos , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Transgênicos
6.
Exp Eye Res ; 130: 87-96, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25450060

RESUMO

All aqueous humor draining through the conventional outflow pathway must cross the endothelium of Schlemm's canal (SC), likely by passing through micron-sized transendothelial pores. SC pores are non-uniformly distributed along the inner wall endothelium, but it is unclear how the distribution of pores relates to the non-uniform or segmental distribution of aqueous humor outflow through the trabecular meshwork. It is hypothesized that regions in the juxtacanalicular tissue (JCT) with higher local outflow should coincide with regions of greater inner wall pore density compared to JCT regions with lower outflow. Three pairs of non-glaucomatous human donor eyes were perfused at 8 mmHg with fluorescent tracer nanospheres to decorate local patterns of outflow segmentation through the JCT. The inner wall was stained for CD31 and/or vimentin and imaged en face using confocal and scanning electron microscopy (SEM). Confocal and SEM images were spatially registered to examine the spatial relationship between inner wall pore density and tracer intensity in the underlying JCT. For each eye, tracer intensity, pore density (n) and pore diameter (D) (for both transcellular "I" and paracellular "B" pores) were measured in 4-7 regions of interest (ROIs; 50 × 150 µm each). Analysis of covariance was used to examine the relationship between tracer intensity and pore density, as well as the relationship between tracer intensity and three pore metrics (nD, nD(2) and nD(3)) that represent the local hydraulic conductivity of the outflow pathway as predicted by various hydrodynamic models. Tracer intensity in the JCT correlated positively with local pore density when considering total pores (p = 0.044) and paracellular B pores on their own (p = 0.016), but not transcellular I-pores on their own (p = 0.54). Local hydraulic conductivity as predicted by the three hydrodynamic models all showed a significant positive correlation with tracer intensity when considering total pores and B-pores (p < 0.0015 and p < 10(-4)) but not I-pores (p > 0.38). These data suggest that aqueous humor passes through micron-sized pores in the inner wall endothelium of SC. Paracellular B-pores appear to have a dominant contribution towards transendothelial filtration across the inner wall relative to transcellular I-pores. Impaired pore formation, as previously described in glaucomatous SC cells, may thereby contribute to greater outflow heterogeneity, outflow obstruction, and IOP elevation in glaucoma.


Assuntos
Humor Aquoso/fisiologia , Endotélio/ultraestrutura , Espaço Intracelular , Limbo da Córnea/ultraestrutura , Malha Trabecular/ultraestrutura , Idoso , Idoso de 80 Anos ou mais , Endotélio/metabolismo , Feminino , Corantes Fluorescentes , Humanos , Hidrodinâmica , Limbo da Córnea/metabolismo , Masculino , Microscopia Eletrônica de Varredura , Nanopartículas , Perfusão , Molécula-1 de Adesão Celular Endotelial a Plaquetas/metabolismo , Doadores de Tecidos , Malha Trabecular/metabolismo , Vimentina/metabolismo
7.
Exp Eye Res ; 127: 224-35, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25128579

RESUMO

The bulk of aqueous humor passing through the conventional outflow pathway must cross the inner wall endothelium of Schlemm's canal (SC), likely through micron-sized transendothelial pores. SC pore density is reduced in glaucoma, possibly contributing to obstructed aqueous humor outflow and elevated intraocular pressure (IOP). Little is known about the mechanisms of pore formation; however, pores are often observed near dome-like cellular outpouchings known as giant vacuoles (GVs) where significant biomechanical strain acts on SC cells. We hypothesize that biomechanical strain triggers pore formation in SC cells. To test this hypothesis, primary human SC cells were isolated from three non-glaucomatous donors (aged 34, 44 and 68), and seeded on collagen-coated elastic membranes held within a membrane stretching device. Membranes were then exposed to 0%, 10% or 20% equibiaxial strain, and the cells were aldehyde-fixed 5 min after the onset of strain. Each membrane contained 3-4 separate monolayers of SC cells as replicates (N = 34 total monolayers), and pores were assessed by scanning electron microscopy in 12 randomly selected regions (∼65,000 µm(2) per monolayer). Pores were identified and counted by four independent masked observers. Pore density increased with strain in all three cell lines (p < 0.010), increasing from 87 ± 36 pores/mm(2) at 0% strain to 342 ± 71 at 10% strain; two of the three cell lines showed no additional increase in pore density beyond 10% strain. Transcellular "I-pores" and paracellular "B-pores" both increased with strain (p < 0.038), however B-pores represented the majority (76%) of pores. Pore diameter, in contrast, appeared unaffected by strain (p = 0.25), having a mean diameter of 0.40 µm for I-pores (N = 79 pores) and 0.67 µm for B-pores (N = 350 pores). Pore formation appears to be a mechanosensitive process that is triggered by biomechanical strain, suggesting that SC cells have the ability to modulate local pore density and filtration characteristics of the inner wall endothelium based on local biomechanical cues. The molecular mechanisms of pore formation and how they become altered in glaucoma may be studied in vitro using stretched SC cells.


Assuntos
Humor Aquoso/metabolismo , Células Endoteliais/fisiologia , Espaço Extracelular , Espaço Intracelular , Limbo da Córnea/citologia , Esclera/fisiologia , Estresse Mecânico , Adulto , Idoso , Comunicação Celular , Contagem de Células , Células Cultivadas , Células Endoteliais/ultraestrutura , Humanos , Microscopia Eletrônica de Varredura , Porosidade , Esclera/ultraestrutura , Doadores de Tecidos , Vacúolos
8.
J Biomech ; 168: 112113, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38648717

RESUMO

Atomic force microscopy (AFM) is a valuable tool for assessing mechanical properties of biological samples, but interpretations of measurements on whole tissues can be difficult due to the tissue's highly heterogeneous nature. To overcome such difficulties and obtain more robust estimates of tissue mechanical properties, we describe an AFM force mapping and data analysis pipeline to characterize the mechanical properties of cryosectioned soft tissues. We assessed this approach on mouse optic nerve head and rat trabecular meshwork, cornea, and sclera. Our data show that the use of repeated measurements, outlier exclusion, and log-normal data transformation increases confidence in AFM mechanical measurements, and we propose that this methodology can be broadly applied to measuring soft tissue properties from cryosections.


Assuntos
Microscopia de Força Atômica , Animais , Microscopia de Força Atômica/métodos , Camundongos , Ratos , Esclera/fisiologia , Esclera/diagnóstico por imagem , Córnea/fisiologia , Córnea/diagnóstico por imagem , Malha Trabecular/fisiologia , Malha Trabecular/diagnóstico por imagem , Crioultramicrotomia/métodos , Disco Óptico/diagnóstico por imagem , Disco Óptico/fisiologia , Fenômenos Biomecânicos
9.
bioRxiv ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38798683

RESUMO

Trabecular meshwork (TM) cell therapy has been proposed as a next-generation treatment for elevated intraocular pressure (IOP) in glaucoma, the most common cause of irreversible blindness. Using a magnetic cell steering technique with excellent efficiency and tissue-specific targeting, we delivered two types of cells into a mouse model of glaucoma: either human adipose-derived mesenchymal stem cells (hAMSCs) or induced pluripotent cell derivatives (iPSC-TM cells). We observed a 4.5 [3.1, 6.0] mmHg or 27% reduction in intraocular pressure (IOP) for nine months after a single dose of only 1500 magnetically-steered hAMSCs, associated with restoration of function to the conventional outflow pathway, as judged by increased outflow facility and TM cellularity. iPSC-TM cells were also effective, but less so, showing only a 1.9 [0.4, 3.3] mmHg or 13% IOP reduction and increased risk of tumorigenicity. In both cases, injected cells remained detectable in the iridocorneal angle three weeks post-transplantation. Based on the locations of the delivered cells, the mechanism of IOP lowering is most likely paracrine signaling. We conclude that magnetically-steered hAMSC cell therapy has potential for long-term treatment of ocular hypertension in glaucoma. One Sentence Summary: A novel magnetic cell therapy provided effective intraocular pressure control in a mouse model of glaucoma, motivating future translational studies.

10.
Transl Vis Sci Technol ; 12(3): 8, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36917118

RESUMO

Purpose: A reference atlas of optic nerve (ON) retinal ganglion cell (RGC) axons could facilitate studies of neuro-ophthalmic diseases by detecting subtle RGC axonal changes. Here we construct an RGC axonal atlas for normotensive eyes in Brown Norway rats, widely used in glaucoma research, and also develop/evaluate several novel metrics of axonal damage in hypertensive eyes. Methods: Light micrographs of entire ON cross-sections from hypertensive and normotensive eyes were processed through a deep learning-based algorithm, AxoNet2.0, to determine axonal morphological properties and were semiquantitatively scored using the Morrison grading scale (MGS) to provide a damage score independent of AxoNet2.0 outcomes. To construct atlases, ONs were conformally mapped onto an ON "template," and axonal morphometric data was computed for each region. We also developed damage metrics based on myelin morphometry. Results: In normotensive eyes, average axon density was ∼0.3 axons/µm2 (i.e., ∼80,000 axons in an ON). We measured axoplasm diameter, eccentricity, cross-sectional area, and myelin g-ratio and thickness. Most morphological parameters exhibited a wide range of coefficients of variation (CoV); however, myelin thickness CoV was only ∼2% in normotensive eyes. In hypertensive eyes, increased myelin thickness correlated strongly with MGS (P < 0.0001). Conclusions: We present the first comprehensive normative RGC axon morphometric atlas for Brown Norway rat eyes. We suggest objective, repeatable damage metrics based on RGC axon myelin thickness for hypertensive eyes. Translational Relevance: These tools can evaluate regional changes in RGCs and overall levels of damage in glaucoma studies using Brown Norway rats.


Assuntos
Glaucoma , Doenças do Nervo Óptico , Ratos , Animais , Células Ganglionares da Retina , Nervo Óptico , Axônios , Doenças do Nervo Óptico/diagnóstico , Ratos Endogâmicos BN
11.
bioRxiv ; 2023 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-38014311

RESUMO

Atomic force microscopy (AFM) is a valuable tool for assessing mechanical properties of biological samples, but interpretations of measurements on whole tissues can be difficult due to the tissue's highly heterogeneous nature. To overcome such difficulties and obtain more robust estimates of tissue mechanical properties, we describe an AFM force mapping and data analysis pipeline to characterize the mechanical properties of cryosectioned soft tissues. We assessed this approach on mouse optic nerve head and rat trabecular meshwork, cornea, and sclera. Our data show that the use of repeated measurements, outlier exclusion, and log-normal data transformation increases confidence in AFM mechanical measurements, and we propose that this methodology can be broadly applied to measuring soft tissue properties from cryosections.

12.
Transl Vis Sci Technol ; 12(3): 9, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36917117

RESUMO

Purpose: Assessment of glaucomatous damage in animal models is facilitated by rapid and accurate quantification of retinal ganglion cell (RGC) axonal loss and morphologic change. However, manual assessment is extremely time- and labor-intensive. Here, we developed AxoNet 2.0, an automated deep learning (DL) tool that (i) counts normal-appearing RGC axons and (ii) quantifies their morphometry from light micrographs. Methods: A DL algorithm was trained to segment the axoplasm and myelin sheath of normal-appearing axons using manually-annotated rat optic nerve (ON) cross-sectional micrographs. Performance was quantified by various metrics (e.g., soft-Dice coefficient between predicted and ground-truth segmentations). We also quantified axon counts, axon density, and axon size distributions between hypertensive and control eyes and compared to literature reports. Results: AxoNet 2.0 performed very well when compared to manual annotations of rat ON (R2 = 0.92 for automated vs. manual counts, soft-Dice coefficient = 0.81 ± 0.02, mean absolute percentage error in axonal morphometric outcomes < 15%). AxoNet 2.0 also showed promise for generalization, performing well on other animal models (R2 = 0.97 between automated versus manual counts for mice and 0.98 for non-human primates). As expected, the algorithm detected decreased in axon density in hypertensive rat eyes (P ≪ 0.001) with preferential loss of large axons (P < 0.001). Conclusions: AxoNet 2.0 provides a fast and nonsubjective tool to quantify both RGC axon counts and morphological features, thus assisting with assessing axonal damage in animal models of glaucomatous optic neuropathy. Translational Relevance: This deep learning approach will increase rigor of basic science studies designed to investigate RGC axon protection and regeneration.


Assuntos
Aprendizado Profundo , Glaucoma , Ratos , Camundongos , Animais , Células Ganglionares da Retina/fisiologia , Estudos Transversais , Modelos Animais de Doenças , Axônios/fisiologia , Glaucoma/diagnóstico
13.
Invest Ophthalmol Vis Sci ; 63(1): 21, 2022 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-35040876

RESUMO

Purpose: Rodent and primate models are commonly used in glaucoma research; however, both have their limitations. The tree shrew (Tupaia belangeri) is an emerging animal model for glaucoma research owing in part to having a human-like optic nerve head anatomy, specifically a collagenous load-bearing lamina. However, the anterior segment anatomy and function have not been extensively studied in the tree shrew. Thus, the purpose of this study was to provide the first detailed examination of the anterior segment anatomy and aqueous outflow facility in the tree shrew. Methods: Aqueous outflow dynamics were measured in five ostensibly normal eyes from three tree shrews using the iPerfusion system over a range of pressures. Gross histological assessment and immunohistochemistry were performed to characterize anterior segment anatomy and to localize several key molecules related to aqueous outflow. Results: Anterior segment anatomy in tree shrews is similar to humans, demonstrating a scleral spur, a multilayered trabecular meshwork and a circular Schlemm's canal with a single lumen. Average outflow facility was 0.193 µL/min/mm Hg (95% confidence interval, 0.153-0.244), and was stable over time. Outflow facility was more similar between contralateral eyes (approximately 5% average difference) than between eyes of different animals. No significant dependence of outflow facility on time or pressure was detected (pressure-flow nonlinearity parameter of 0.01 (95% % confidence interval, -0.29 to 0.31 CI µL/min/mm Hg). Conclusions: These studies lend support to the usefulness of the tree shrew as a novel animal model in anterior segment glaucoma and pharmacology research. The tree shrew's cost, load-bearing collagenous lamina cribrosa, and lack of washout or anterior chamber deepening provides a distinct experimental and anatomic advantage over the current rodent and nonhuman primate models used for translational research.


Assuntos
Segmento Anterior do Olho/anatomia & histologia , Humor Aquoso/fisiologia , Glaucoma/patologia , Pressão Intraocular/fisiologia , Animais , Segmento Anterior do Olho/fisiologia , Modelos Animais de Doenças , Feminino , Glaucoma/metabolismo , Masculino , Tupaia
14.
Transl Vis Sci Technol ; 11(5): 7, 2022 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-35536721

RESUMO

Purpose: Scleral stiffening may protect against glaucomatous retinal ganglion cell (RGC) loss or dysfunction associated with ocular hypertension. Here, we assess the potential neuroprotective effects of two treatments designed to stiffen either the entire posterior sclera or only the sclera adjacent to the peripapillary sclera in an experimental model of glaucoma. Methods: Rat sclerae were stiffened in vivo using either genipin (crosslinking the entire posterior sclera) or a regionally selective photosensitizer, methylene blue (stiffening only the juxtaperipapillary region surrounding the optic nerve). Ocular hypertension was induced using magnetic microbeads delivered to the anterior chamber. Morphological and functional outcomes, including optic nerve axon count and appearance, retinal thickness measured by optical coherence tomography, optomotor response, and electroretinography traces, were assessed. Results: Both local (juxtaperipapillary) and global (whole posterior) scleral stiffening treatments were successful at increasing scleral stiffness, but neither provided demonstrable neuroprotection in hypertensive eyes as assessed by RGC axon counts and appearance, optomotor response, or electroretinography. There was a weak indication that scleral crosslinking protected against retinal thinning as assessed by optical coherence tomography. Conclusions: Scleral stiffening was not demonstrated to be neuroprotective in ocular hypertensive rats. We hypothesize that the absence of benefit may in part be due to RGC loss associated with the scleral stiffening agents themselves (mild in the case of genipin, and moderate in the case of methylene blue), negating any potential benefit of scleral stiffening. Translational Relevance: The development of scleral stiffening as a neuroprotective treatment will require the identification of better tolerated stiffening protocols and further preclinical testing.


Assuntos
Glaucoma , Esclera , Animais , Pressão Intraocular , Azul de Metileno/farmacologia , Azul de Metileno/uso terapêutico , Neuroproteção , Ratos
15.
Mol Vis ; 17: 199-209, 2011 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-21264055

RESUMO

PURPOSE: The conventional outflow pathway provides the primary source of resistance to aqueous humor drainage, regulating intraocular pressure. Despite large pressure gradients across the inner wall of Schlemm's canal (SC), cells remain attached to their basement membrane. The goal of this study was to examine integrin-extracellular matrix binding partners of the inner wall basement membrane that facilitate attachment. METHODS: Human outflow tissues and cultured cells were analyzed by immunofluorescence and western blotting, respectively. Radial sections of human donor eyes or en face preparations of human SC inner wall were probed with antibodies that specifically recognize collagens (Type I, III, and IV), laminins (LM-332 and LM-511) and laminin-specific integrin subunits, α3, α6, ß1, and ß4, typical of vascular endothelia. RESULTS: Immunofluorescence studies showed collagens Type I and IV in the SC basement membrane but not collagen III. As expected with mature vascular endothelia, SC cells in situ expressed LM-511 but not LM-332. Significantly, the integrin α6 subunit was expressed uniquely by SC. En face labeling of the inner wall displayed integrin α6 colocalizing with LM α5 at the cell periphery. Western blots of cultured human SC endothelial cell monolayers confirmed expression of Type I collagen, collagen IV, LM-511, and the α6 integrin subunit. Interestingly, LM-332 was present in cultured SC cells up to 60 days post-confluence. CONCLUSIONS: Even though cells of the inner wall endure pressure gradients in the basal to apical direction, opposite of other endothelia, human SC cells express basement membrane proteins and their cognate integrins typical of vascular endothelia.


Assuntos
Humor Aquoso/metabolismo , Membrana Basal/metabolismo , Matriz Extracelular/metabolismo , Regulação da Expressão Gênica , Integrinas/química , Adulto , Idoso , Colágeno Tipo I/biossíntese , Colágeno Tipo IV/biossíntese , Humanos , Lactente , Integrina alfa6/biossíntese , Pressão Intraocular , Microscopia Confocal/métodos , Microscopia de Fluorescência/métodos , Pessoa de Meia-Idade
16.
Acta Biomater ; 134: 379-387, 2021 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-34274532

RESUMO

Optic nerve head (ONH) biomechanics is centrally involved in the pathogenesis of glaucoma, a blinding ocular condition often characterized by elevation and fluctuation of the intraocular pressure and resulting loads on the ONH. Further, tissue viscoelasticity is expected to strongly influence the mechanical response of the ONH to mechanical loading, yet the viscoelastic mechanical properties of the ONH remain unknown. To determine these properties, we conducted micromechanical testing on porcine ONH tissue samples, coupled with finite element modeling based on a mixture model consisting of a biphasic material with a viscoelastic solid matrix. Our results provide a detailed description of the viscoelastic properties of the porcine ONH at each of its four anatomical quadrants (i.e., nasal, superior, temporal, and inferior). We showed that the ONH's viscoelastic mechanical response can be explained by a dual mechanism of fluid flow and solid matrix viscoelasticity, as is common in other soft tissues. We obtained porcine ONH properties as follows: matrix Young's modulus E=1.895[1.056,2.391] kPa (median [min., max.]), Poisson's ratio ν=0.142[0.060,0.312], kinetic time-constant τ=214[89,921] sec, and hydraulic permeability k=3.854×10-1[3.457×10-2,9.994×10-1] mm4/(N.sec). These values can be used to design and fabricate physiologically appropriate ex vivo test environments (e.g., 3D cell culture) to further understand glaucoma pathophysiology. STATEMENT OF SIGNIFICANCE: Optic nerve head (ONH) biomechanics is an important aspect of the pathogenesis of glaucoma, the leading cause of irreversible blindness. The ONH experiences time-varying loads, yet the viscoelastic behavior of this tissue has not been characterized. Here, we measure the time-dependent response of the ONH in porcine eyes and use mechanical modeling to provide time-dependent mechanical properties of the ONH. This information allows us to identify time-varying stimuli in vivo which have timescales matching the characteristic response times of the ONH, and can also be used to design and fabricate ex vivo 3D cultures to study glaucoma pathophysiology in a physiologically relevant environment, enabling the discovery of new generations of glaucoma medications focusing on neuroprotection.


Assuntos
Glaucoma , Disco Óptico , Animais , Fenômenos Biomecânicos , Análise de Elementos Finitos , Pressão Intraocular , Suínos
17.
Invest Ophthalmol Vis Sci ; 62(3): 18, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33704361

RESUMO

Purpose: Re-cellularization of the trabecular meshwork (TM) using stem cells is a potential novel treatment for ocular hypertension associated with glaucoma. To assess the therapeutic efficacy of this approach, improved in vivo and ex vivo models of TM pathophysiology are needed. Here, we investigate whether oxidative stress, induced by hydrogen peroxide (H2O2), can model glaucomatous ocular hypertension in the readily available porcine anterior segment organ culture model. Methods: The impact of H2O2 on TM cell viability and function was first evaluated in vitro using primary porcine TM cells. Oxidative stress was then induced by H2O2 infusion into perfused porcine anterior segments. Trabecular meshwork function was assessed by tracking matrix metalloproteinase (MMP) activity and the ability of the preparation to maintain intraocular pressure (IOP) homeostasis after a flow challenge (doubled fluid infusion rate). Finally, the TM was evaluated histologically. Results: H2O2 treatment resulted in a titratable reduction in cellularity across multiple primary TM cell donor strains. In organ culture preparations, H2O2-treated eyes showed impaired IOP homeostasis (i.e., IOPs stabilized at higher levels after a flow challenge vs. control eyes). This result was consistent with reduced MMP activity and TM cellularity; however, damage to the TM microstructure was not histologically evident in anterior segments receiving H2O2. Conclusions: Titrated H2O2 infusion resulted in TM cellular dysfunction without destruction of TM structure. Thus, this porcine organ culture model offers a useful platform for assessing trabecular meshwork therapies to treat ocular hypertension associated with glaucoma.


Assuntos
Modelos Animais de Doenças , Glaucoma de Ângulo Aberto/induzido quimicamente , Peróxido de Hidrogênio/farmacologia , Estresse Oxidativo/efeitos dos fármacos , Malha Trabecular/efeitos dos fármacos , Animais , Sobrevivência Celular , Glaucoma de Ângulo Aberto/enzimologia , Glaucoma de Ângulo Aberto/patologia , Pressão Intraocular/efeitos dos fármacos , Metaloproteinases da Matriz/metabolismo , Técnicas de Cultura de Órgãos , Fagocitose/fisiologia , Suínos , Malha Trabecular/enzimologia , Malha Trabecular/patologia
18.
iScience ; 24(2): 102042, 2021 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-33532718

RESUMO

Controlling intraocular pressure (IOP) remains the mainstay of glaucoma therapy. The trabecular meshwork (TM), the key tissue responsible for aqueous humor (AH) outflow and IOP maintenance, is very sensitive to mechanical forces. However, it is not understood whether Piezo channels, very sensitive mechanosensors, functionally influence AH outflow. Here, we characterize the role of Piezo1 in conventional AH outflow. Immunostaining and western blot analysis showed that Piezo1 is widely expressed by TM. Patch-clamp recordings in TM cells confirmed the activation of Piezo1-derived mechanosensitive currents. Importantly, the antagonist GsMTx4 for mechanosensitive channels significantly decreased steady-state facility, yet activation of Piezo1 by the specific agonist Yoda1 did not lead to a facility change. Furthermore, GsMTx4, but not Yoda1, caused a significant increase in ocular compliance, a measure of the eye's transient response to IOP perturbation. Our findings demonstrate a potential role for Piezo1 in conventional outflow, likely under pathological and rapid transient conditions.

19.
Elife ; 102021 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-33783352

RESUMO

Glucocorticoids are widely used as an ophthalmic medication. A common, sight-threatening adverse event of glucocorticoid usage is ocular hypertension, caused by dysfunction of the conventional outflow pathway. We report that netarsudil, a rho-kinase inhibitor, decreased glucocorticoid-induced ocular hypertension in patients whose intraocular pressures were poorly controlled by standard medications. Mechanistic studies in our established mouse model of glucocorticoid-induced ocular hypertension show that netarsudil both prevented and reduced intraocular pressure elevation. Further, netarsudil attenuated characteristic steroid-induced pathologies as assessed by quantification of outflow function and tissue stiffness, and morphological and immunohistochemical indicators of tissue fibrosis. Thus, rho-kinase inhibitors act directly on conventional outflow cells to prevent or attenuate fibrotic disease processes in glucocorticoid-induced ocular hypertension in an immune-privileged environment. Moreover, these data motivate the need for a randomized prospective clinical study to determine whether netarsudil is indeed superior to first-line anti-glaucoma drugs in lowering steroid-induced ocular hypertension.


Assuntos
Anti-Hipertensivos/farmacologia , Benzoatos/farmacologia , Pressão Intraocular/efeitos dos fármacos , Hipertensão Ocular/tratamento farmacológico , beta-Alanina/análogos & derivados , Quinases Associadas a rho/antagonistas & inibidores , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Animais , Feminino , Humanos , Recém-Nascido , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Pessoa de Meia-Idade , Estudos Prospectivos , Tonometria Ocular , beta-Alanina/farmacologia
20.
Transl Vis Sci Technol ; 9(10): 8, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32974080

RESUMO

Purpose: Genipin has been proposed as a possible neuroprotective therapy in myopia and glaucoma. Here, we aim to determine the effects of prolonged genipin-induced scleral stiffening on visual function. Methods: Eyes from Brown Norway rats were treated in vivo with either a single 15 mM genipin retrobulbar injection or sham retrobulbar injection and were compared to naïve eyes. Intraocular pressure, optomotor response, and electroretinograms were repeatedly measured over 4 weeks following retrobulbar injections to determine visual and retinal function. At 4 weeks, we quantified retinal ganglion cell axon counts. Finally, molecular changes in gene and protein expression were analyzed via real-time polymerase chain reaction (RT-PCR) and proteomics. Results: Retrobulbar injection of genipin did not affect intraocular pressure (IOP) or retinal function, nor have a sustained impact on visual function. Although genipin-treated eyes had a small decrease in retinal ganglion cell axon counts compared to contralateral sham-treated eyes (-8,558 ± 18,646; mean ± SD), this was not statistically significant (P = 0.206, n = 9). Last, we did not observe any changes in gene or protein expression due to genipin treatment. Conclusions: Posterior scleral stiffening with a single retrobulbar injection of 15 mM genipin causes no sustained deficits in visual or retinal function or at the molecular level in the retina and sclera. Retinal ganglion cell axon morphology appeared normal. Translational Significance: These results support future in vivo studies to determine the efficacy of genipin-induced posterior scleral stiffening to help treat ocular diseases, like myopia and glaucoma.


Assuntos
Glaucoma , Esclera , Animais , Iridoides/farmacologia , Ratos , Retina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA