Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J ; 45(28): 2519-2532, 2024 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-38820201

RESUMO

BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.


Assuntos
Endocardite , Falha de Prótese , Infecções Relacionadas à Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/mortalidade , Endocardite/cirurgia , Endocardite/mortalidade , Remoção de Dispositivo , Próteses Valvulares Cardíacas/efeitos adversos , Bioprótese/efeitos adversos , Resultado do Tratamento , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
2.
Curr Cardiol Rep ; 26(7): 767-775, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38806975

RESUMO

PURPOSE OF REVIEW: This review explores the epidemiology, clinical traits, and diagnosis of Transcatheter Aortic Valve Replacement-Associated Infective Endocarditis (TAVR-IE) and mitral transcatheter edge-to-edge repair infective endocarditis (TEER-IE), focusing on a multimodal imaging approach. It addresses the rising prevalence of TAVR and TEER, emphasizing the need to understand long-term complications and clinical consequences, which poses significant challenges despite advancements in valve technology. RECENT FINDINGS: Studies report a variable incidence of TAVR-IE and TEER-IE influenced by diverse patient risk profiles and procedural factors. Younger age, male gender, and certain comorbidities emerge as patient-related risk factors. Procedure-related factors include intervention location, valve type, and technical aspects. Microbiologically, Staphylococcus aureus, Viridans Group Streptococcus, and Enterococcus are frequently encountered pathogens. TAVR-IE and TEER-IE diagnosis involves a multimodal imaging approach due to limitations in echocardiography. Blood cultures and imaging aid identification, with Fluorescence in situ hybridization is showing promise. Treatment encompasses medical management with antibiotics and, when necessary, surgical intervention. The management approach requires a multidisciplinary "Endocarditis Team." This review underscores the need for continued research to refine risk prediction, enhance diagnostic accuracy, and optimize management strategies for TAVR-IE, considering the evolving landscape of transcatheter interventions.


Assuntos
Infecções Relacionadas à Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Risco , Infecções Relacionadas à Prótese/terapia , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Próteses Valvulares Cardíacas/microbiologia , Antibacterianos/uso terapêutico , Endocardite Bacteriana/microbiologia , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/terapia , Endocardite/microbiologia , Endocardite/etiologia
3.
Ann Cardiothorac Surg ; 13(3): 206-210, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38841082

RESUMO

Two families of randomized trials comparing transcatheter aortic valve replacement (TAVR) to surgery for both the Balloon Expandable Valve and the Supra Annular Self-Expanding Valve have been completed to include all surgical risk levels. The result of these trials has led to the approval of TAVR for symptomatic severe aortic stenosis without using risk level as the sole criterion. We have seen an explosion of TAVR in the US to over 98,000 commercial cases in 2022. We have also seen a rapid increase in the use of TAVR in patients less than 65 years of age. With these increases, it is important to ask if they are being driven largely by the data or just the desire for TAVR by both patients and their physicians. Heart team input is a class I indication when deciding between TAVR and surgery. For surgical members of the heart team to appropriately counsel patients, a full understanding of what the TAVR surgery trials tell us as well as what they do not is essential. In this article we will explore those questions.

4.
Heart Int ; 18(1): 26-29, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39006462

RESUMO

Transcatheter aortic valve replacement (TAVR) has undergone significant advancements in the last two decades, expanding its indications and refining transcatheter heart valve (THV) and delivery system designs to improve procedural success and patient outcomes. This review focuses on the Navitor™ valve, a third-generation intra-annular Portico™ valve (Abbott Structural Heart, St Paul, MN, USA) designed to address TAVR complications, particularly paravalvular leak (PVL). We present an overview of the Navitor™ system, comparing it to the first-generation Portico™ THV in terms of THV design, key iterations and clinical outcomes. The Navitor™ THV introduces two key refinements-a protective outer sealing skirt and a more flexible delivery system. These enhancements have led to a significant reduction in 30 day PVL rates, from 6.3% with the first-generation Portico™ to 0% with the Navitor™ system. Additionally, the Navitor™ system exhibited lower rates of severe bleeding (27.3% versus 13.1%) and major vascular complications (5.8% versus 0.7%) compared with the first-generation Portico™. The Navitor™ valve represents a promising advancement in TAVR technology, with notable reductions in complications such as PVL, severe bleeding, and major vascular issues, compared with its predecessor. While further research is needed to assess long-term durability, these results underscore its potential benefits in enhancing patient outcomes and reducing complications. This review provides insights into the evolving landscape of TAVR technology and its quantifiable impact on patient care.

5.
MDM Policy Pract ; 9(1): 23814683231225667, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38250668

RESUMO

Background. Tricuspid regurgitation (TR) is a high-prevalence disease associated with poor quality of life and mortality. This quantitative patient preference study aims to identify TR patients' perspectives on risk-benefit tradeoffs. Methods. A discrete-choice experiment was developed to explore TR treatment risk-benefit tradeoffs. Attributes (levels) tested were treatment (procedure, medical management), reintervention risk (0%, 1%, 5%, 10%), medications over 2 y (none, reduce, same, increase), shortness of breath (none/mild, moderate, severe), and swelling (never, 3× per week, daily). A mixed logit regression model estimated preferences and calculated predicted probabilities. Relative attribute importance was calculated. Subgroup analyses were performed. Results. An online survey was completed by 150 TR patients. Shortness of breath was the most important attribute and accounted for 65.8% of treatment decision making. The average patients' predicted probability of preferring a "procedure-like" profile over a "medical management-like" profile was 99.7%. This decreased to 78.9% for a level change from severe to moderate in shortness of breath in the "medical management-like" profile. Subgroup analysis confirmed that patients older than 64 y had a stronger preference to avoid severe shortness of breath compared with younger patients (P < 0.02), as did severe or worse TR patients relative to moderate. New York Heart Association class I/II patients more strongly preferred to avoid procedural reintervention risk relative to class III/IV patients (P < 0.03). Conclusion. TR patients are willing to accept higher procedural reintervention risk if shortness of breath is alleviated. This risk tolerance is higher for older and more symptomatic patients. These results emphasize the appropriateness of developing TR therapies and the importance of addressing symptom burden. Highlights: This study provides quantitative patient preference data from clinically confirmed tricuspid regurgitation (TR) patients to understand their treatment preferences.Using a targeted literature search and patient, physician, and Food and Drug Administration feedback, a cross-sectional survey with a discrete-choice experiment that focused on 5 of the most important attributes to TR patients was developed and administered online.TR patients are willing to accept higher procedural reintervention risk if shortness of breath is alleviated, and this risk tolerance is higher for older and more symptomatic patients.

6.
J Am Heart Assoc ; 13(5): e032784, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38390821

RESUMO

BACKGROUND: Prior studies investigating the impact of residual mitral regurgitation (MR), tricuspid regurgitation (TR), and elevated predischarge transmitral mean pressure gradient (TMPG) on outcomes after mitral transcatheter edge-to-edge repair (TEER) have assessed each parameter in isolation. We sought to examine the prognostic value of combining predischarge MR, TR, and TMPG to study long-term outcomes after TEER. METHODS AND RESULTS: We reviewed the records of 291 patients who underwent successful mitral TEER at our institution between March 2014 and June 2022. Using well-established outcomes-related cutoffs for predischarge MR (≥moderate), TR (≥moderate), and TMPG (≥5 mm Hg), 3 echo profiles were developed based on the number of risk factors present (optimal: 0 risk factors, mixed: 1 risk factor, poor: ≥2 risk factors). Discrimination of the profiles for predicting the primary composite end point of all-cause mortality and heart failure hospitalization at 2 years was examined using Cox regression. Overall, mean age was 76.7±10.6 years, 43.3% were women, and 53% had primary MR. Two-year event-free survival was 61%. Predischarge TR≥moderate, MR≥moderate, and TMPG≥5 mm Hg were risk factors associated with the primary end point. Compared with the optimal profile, there was an incremental risk in 2-year event-rate with each worsening profile (optimal as reference; mixed profile: hazard ratio (HR), 2.87 [95% CI, 1.71-5.17], P<0.001; poor profile: HR, 3.76 [95% CI, 1.84-6.53], P<0.001). Echocardiographic profile was statistically associated with the 2-year mortality end point (optimal as reference; mixed profile: HR, 3.55 [95% CI, 1.81-5.96], P<0.001; poor profile: HR, 3.39 [95% CI, 2.56-7.33], P=0.02). CONCLUSIONS: The echocardiographic profile integrating predischarge TR, MR, and TMPG presents a novel prognostic stratification tool for patients undergoing mitral TEER.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Mercúrio , Insuficiência da Valva Mitral , Insuficiência da Valva Tricúspide , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Ecocardiografia , Instalações de Saúde , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco
7.
JTCVS Open ; 17: 47-54, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38420548

RESUMO

Background: Although various hemodynamic parameters to assess prosthetic performance are available, prosthesis-patient mismatch (PPM) is defined exclusively by effective orifice area (EOA) index thresholds. Adjusting for the Society of Thoracic Surgeons predicted risk of mortality (STS PROM), we aimed to explore the added value of postoperative hemodynamic parameters for the prediction of all-cause mortality at 5 years after aortic valve replacement. Methods: Data were obtained from the Pericardial Surgical Aortic Valve Replacement (PERIGON) Pivotal Trial, a multicenter prospective cohort study examining the performance of the Avalus bioprosthesis. Candidate predictors were assessed at the first follow-up visit; patients who had no echocardiography data, withdrew consent, or died before this visit were excluded. Candidate predictors included peak jet velocity, mean pressure gradient, EOA, predicted and measured EOA index, Doppler velocity index, indexed internal prosthesis orifice area, and categories for PPM. The performance of Cox models was investigated using the c-statistic and net reclassification improvement (NRI), among other tools. Results: A total of 1118 patients received the study valve, of whom 1022 were eligible for the present analysis. In univariable analysis, STS PROM was the sole significant predictor of all-cause mortality (hazard ratio, 1.40; 95% confidence interval, 1.26-1.55). When extending the STS PROM with single hemodynamic parameters, neither the c-statistics nor the NRIs demonstrated added prognostic value compared to a model with STS PROM alone. Similar findings were observed when multiple hemodynamic parameters were added. Conclusions: The STS PROM was found to be the main predictor of patient prognosis. The additional prognostic value of postoperative hemodynamic parameters for the prediction of all-cause mortality was limited.

8.
JTCVS Open ; 19: 68-90, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39015469

RESUMO

Objective: New echocardiographic definitions have been proposed for hemodynamic structural valve deterioration. We aimed to study their consistency in classifying structural valve deterioration after surgical aortic valve replacement. Methods: Data were used of patients undergoing surgical aortic valve replacement in a multicenter, prospective cohort study with a 5-year follow-up. All patients received the same stented bioprosthesis. Echocardiographic parameters were assessed by an independent core laboratory. Moderate or greater stenotic hemodynamic structural valve deterioration was defined according to Capodanno and colleagues, Dvir and colleagues, and the Valve Academic Research Consortium 3; regurgitation data were not considered in this analysis. Consistency was quantified on the basis of structural valve deterioration classification at subsequent time points. Results: A total of 1118 patients received implants. Patients' mean age was 70 years, and 75% were male. Hemodynamic structural valve deterioration at any visit was present in 51 patients (4.6%), 32 patients (2.9%), and 34 patients (3.0%) according to Capodanno, Dvir, and Valve Academic Research Consortium 3. A total of 1064 patients (95%) were never labeled with structural valve deterioration by any definition. After the first classification with structural valve deterioration, 59%, 59%, and 65% had no subsequent structural valve deterioration classification according to Capodanno, Dvir, and Valve Academic Research Consortium 3, respectively. Conclusions: The current definitions of hemodynamic structural valve deterioration are strong negative predictors but inconsistent positive discriminators for the detection of stenotic hemodynamic structural valve deterioration. Although the diagnosis of structural valve deterioration may be categorical, echocardiographic indices lack this degree of precision in the first 5 years after surgical aortic valve replacement. The inconsistency of current structural valve deterioration definitions impedes the detection of true valve degeneration, which challenges the clinical usefulness of these definitions.

9.
Am J Cardiol ; 221: 9-18, 2024 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-38636627

RESUMO

Patients with small aortic annuli (SAA) pose a challenge in patients undergoing aortic valve replacement because of the potential for prosthesis-patient mismatch (PPM). This study aimed to compare the clinical and hemodynamic outcomes of self-expandable valve (SEV) versus balloon-expandable valve (BEV) transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis and SAA. All patients who underwent TAVI for severe native aortic stenosis with a SAA between January 2018 and December 2022 were retrospectively included in the study from a single center. Propensity score matching was performed to balance the baseline characteristics. Bioprosthesis valve dysfunction was based on modified Valve Academic Research Consortium 3 criteria. A total of 1,170 TAVI procedures were performed between 2018 and 2022. After applying the exclusion criteria, 332 patients reported a SAA at computed tomography scan, and the matching created 109 balanced pairs. Echocardiographic data at discharge showed higher mean transvalvular gradients (p <0.001), higher grades of mitral regurgitation (p = 0.029), and lower ejection fraction (p <0.043) in BEVs than SEVs. At follow-up, significant differences favoring the SEV group regarding bioprosthesis valve dysfunction were observed (p = 0.002), especially in terms of severe PPM (p = 0.046) and at least moderate structural valve deterioration (p = 0.040). In conclusion, TAVI in patients with SAA using a BEV was associated with lower valve areas, higher mean pressure gradients, and PPM (including severe) than a SEV. Short- and midterm all-cause and cardiac-related mortality did not differ between the 2 groups. Future randomized studies with extended follow-ups are warranted to validate these outcomes.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Hemodinâmica , Pontuação de Propensão , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Masculino , Feminino , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Hemodinâmica/fisiologia , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Idoso , Ecocardiografia
10.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38710669

RESUMO

OBJECTIVES: The objective of this analysis was to assess the normal haemodynamic performance of contemporary surgical aortic valves at 1 year postimplant in patients undergoing surgical aortic valve replacement for significant valvular dysfunction. By pooling data from 4 multicentre studies, this study will contribute to a better understanding of the effectiveness of surgical aortic valve replacement procedures, aiding clinicians and researchers in making informed decisions regarding valve selection and patient management. METHODS: Echocardiograms were assessed by a single core laboratory. Effective orifice area, dimensionless velocity index, mean aortic gradient, peak aortic velocity and stroke volume were evaluated. RESULTS: The cohort included 2958 patients. Baseline age in the studies ranged from 70.1 ± 9.0 to 83.3 ± 6.4 years, and Society of Thoracic Surgeons risk of mortality was 1.9 ± 0.7 to 7.5 ± 3.4%. Twenty patients who had received a valve model implanted in fewer than 10 cases were excluded. Ten valve models (all tissue valves; n = 2938 patients) were analysed. At 1 year, population mean effective orifice area ranged from 1.46 ± 0.34 to 2.12 ± 0.59 cm2, and dimensionless velocity index, from 0.39 ± 0.07 to 0.56 ± 0.15. The mean gradient ranged from 8.6 ± 3.4 to 16.1 ± 6.2 mmHg with peak aortic velocity of 1.96 ± 0.39 to 2.65 ± 0.47 m/s. Stroke volume was 75.3 ± 19.6 to 89.8 ± 24.3 ml. CONCLUSIONS: This pooled cohort is the largest to date of contemporary surgical aortic valves with echocardiograms analysed by a single core lab. Overall haemodynamic performance at 1 year ranged from good to excellent. These data can serve as a benchmark for other studies and may be useful to evaluate the performance of bioprosthetic surgical valves over time. CLINICAL TRIAL REGISTRATION NUMBER: NCT02088554, NCT02701283, NCT01586910 and NCT01531374.


Assuntos
Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Hemodinâmica , Humanos , Hemodinâmica/fisiologia , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Idoso , Feminino , Masculino , Idoso de 80 Anos ou mais , Implante de Prótese de Valva Cardíaca/métodos , Ecocardiografia , Pessoa de Meia-Idade , Desenho de Prótese
11.
Artigo em Inglês | MEDLINE | ID: mdl-38871537

RESUMO

BACKGROUND: Permanent pacemaker implantation (PPI) rates following transcatheter aortic valve replacement (TAVR) remain a concern. We assessed the PPI rates over time in patients implanted with an Evolut supra-annular, self-expanding transcatheter valve from the US STS/ACC TVT Registry. METHODS: Patients who underwent TAVR with an Evolut R, Evolut PRO or Evolut PRO+ valve between July 2018 (Q3) and June 2021 (Q2) were included. PPI rates were reported by calendar quarter. In-hospital PPI rates were reported as proportions and 30-day rates as Kaplan-Meier estimates. A Cox regression model was used to determine potential predictors of a new PPI within 30 days of the TAVR procedure. RESULTS: From July 2018 to June 2021, 54,014 TAVR procedures were performed using Evolut valves. Mean age was 79.3 ± 8.8 years and 49.2 % were male. The 30-day PPI rate was 16.6 % in 2018 (Q3) and 10.8 % in 2021 (Q2, 34.9 % decrease, p < 0.001 for trend across all quarters). The in-hospital PPI rate decreased by 40.1 %; from 14.7 % in 2018 (Q3) to 8.8 % in 2021 (Q2) (p < 0.001 for trend across all quarters). Significant predictors of a new PPI within 30 days included a baseline conduction defect, history of atrial fibrillation, home oxygen, and diabetes mellitus. CONCLUSION: From 2018 to 2021, TAVR with an Evolut transcatheter heart valve in over 50,000 patients showed a significant decreasing trend in the rates of in-hospital and 30-day PPI, representing the lowest rate of PPI in any large real-world registry of Evolut. During the same evaluated period, high device success and shorter length of stay was also observed.

12.
J Am Heart Assoc ; 13(11): e033447, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38780160

RESUMO

BACKGROUND: Coronary microvascular function and hemodynamics may play a role in coronary circulation and myocardial remodeling in patients with aortic stenosis (AS). We aimed to evaluate the relationship between myocardial blood flow and myocardial function in patients with AS, no AS, and aortic valve sclerosis. METHODS AND RESULTS: We included consecutive patients who had resting transthoracic echocardiography and clinically indicated positron emission tomography myocardial perfusion imaging to capture their left ventricular ejection fraction, global longitudinal strain (GLS), and myocardial flow reserve (MFR). The primary outcome was major adverse cardiovascular event (all-cause mortality, myocardial infarction, or late revascularization). There were 2778 patients (208 with aortic sclerosis, 39 with prosthetic aortic valve, 2406 with no AS, and 54, 49, and 22 with mild, moderate, and severe AS, respectively). Increasing AS severity was associated with impaired MFR (P<0.001) and GLS (P<0.001), even when perfusion was normal. Statistically significant associations were noted between MFR and GLS, MFR and left ventricular ejection fraction, and MFR and left ventricular ejection fraction reserve. After a median follow-up of 349 (interquartile range, 116-662) days, 4 (7.4%), 5 (10.2%), and 6 (27.3%) patients experienced a major adverse cardiovascular event in the mild, moderate, and severe AS groups, respectively. In a matched-control analysis, patients with mild-to-moderate AS had higher rates of impaired MFR (52.9% versus 39.9%; P=0.048) and major adverse cardiovascular event (11.8% versus 3.0%; P=0.002). CONCLUSIONS: Despite lack of ischemia, as severity of AS increased, MFR decreased and GLS worsened, reflecting worse coronary microvascular health and myocardial remodeling. Positron emission tomography-derived MFR showed a significant independent correlation with left ventricular ejection fraction and GLS. Patients with prosthetic aortic valve showed a high prevalence of impaired MFR.


Assuntos
Estenose da Valva Aórtica , Reserva Fracionada de Fluxo Miocárdico , Microcirculação , Imagem de Perfusão do Miocárdio , Volume Sistólico , Função Ventricular Esquerda , Remodelação Ventricular , Humanos , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Feminino , Masculino , Remodelação Ventricular/fisiologia , Idoso , Função Ventricular Esquerda/fisiologia , Imagem de Perfusão do Miocárdio/métodos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Volume Sistólico/fisiologia , Microcirculação/fisiologia , Circulação Coronária/fisiologia , Ecocardiografia , Índice de Gravidade de Doença , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Estudos Retrospectivos , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
13.
Struct Heart ; 8(1): 100227, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38283572

RESUMO

Bicuspid aortic valve (BAV) is a common congenital valvular malformation, which may lead to early aortic valve disease and bicuspid-associated aortopathy. A novel BAV classification system was recently proposed to coincide with transcatheter aortic valve replacement being increasingly considered in younger patients with symptomatic BAV, with good clinical results, yet without randomized trial evidence. Procedural technique, along with clinical outcomes, have considerably improved in BAV patients compared with tricuspid aortic stenosis patients undergoing transcatheter aortic valve replacement. The present review summarizes the novel BAV classification systems and examines contemporary surgical and transcatheter approaches.

14.
Struct Heart ; 8(4): 100293, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39100579

RESUMO

Background: The Navitor Investigational Device Exemption (IDE) study is a prospective, multicenter, global study assessing the safety and effectiveness of the Navitor valve in a population with severe, symptomatic aortic stenosis who are at high and extreme surgical risk. The impact of pre-existing conduction abnormalities and implantation technique on new permanent pacemaker implantation (PPI) for the Navitor platform is not fully understood. Therefore, the goal of this analysis was to investigate the associations between patient and procedural factors and the 30-day new PPI rate. Methods: A total of 260 patients who underwent implantation of a Navitor valve in the Navitor IDE study were reviewed. Patients with preprocedural permanent pacemakers (n = 28) were excluded. Baseline risk factors were assessed for statistical significance. Multivariable logistic regression analyses were performed to identify independent predictors of new PPI. Results: Mean age of the pacemaker-naïve population was 83.3 ± 5.2 years, 58.6% were female, average Society of Thoracic Surgeons score was 3.8% ± 1.9%, median frailty score was 1 (interquartile range 1, 2), and 17.7% were deemed at extreme surgical risk. Pre-existing first-degree atrioventricular block and right bundle branch block significantly increased the risk of new PPI postimplantation, whereas left bundle branch block did not. Membranous septum length in relation to noncoronary cusp implant depth was a significant predictor of new PPI, with higher rates of new PPI observed when noncoronary cusp implant depth exceeded membranous septum length. Analysis of implant depth alone revealed deeper implants were associated with a higher rate of new PPI, regardless of patient baseline conduction abnormality. Conclusions: The 30-day rate of new PPI in the Navitor IDE study is associated with patient pre-existing baseline conduction disturbances and implantation depth.

15.
Am J Cardiol ; 223: 147-155, 2024 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-38641189

RESUMO

There are limited data from randomized controlled trials assessing the impact of transcatheter aortic valve replacement (TAVR) or surgery in women with aortic stenosis and small aortic annuli. We evaluated 2-year clinical and hemodynamic outcomes after aortic valve replacement to understand acute valve performance and early and midterm clinical outcomes. This post hoc analysis pooled women enrolled in the randomized, prospective, multicenter Evolut Low Risk and Surgical Replacement and Transcatheter Aortic Valve Implantation (SURTAVI) intermediate risk trials. Women with severe aortic stenosis at low or intermediate surgical risk who had a computed tomography-measured annular perimeter of ≤72.3 mm were included and underwent self-expanding, supra-annular TAVR or surgery. The primary end point was 2-year all-cause mortality or disabling stroke rate. The study included 620 women (323 TAVR, 297 surgery) with a mean age of 78 years. At 2 years, the all-cause mortality or disabling stroke was 6.5% for TAVR and 8.0% for surgery, p = 0.47. Pacemaker rates were 20.0% for TAVR and 8.3% for surgery, p <0.001. The mean effective orifice area at 2 years was 1.9 ± 0.5 cm2 for TAVR and 1.6 ± 0.5 cm2 for surgery and the mean gradient was 8.0 ± 4.1 versus 12.7 ± 6.0 mm Hg, respectively (both p <0.001). Moderate or severe patient-prothesis mismatch at discharge occurred in 10.9% of patients who underwent TAVR and 33.2% of patients who underwent surgery, p <0.001. In conclusion, in women with small annuli, the clinical outcomes to 2 years were similar between self-expanding, supra-annular TAVR and surgery, with better hemodynamics in the TAVR group and fewer pacemakers in the surgical group.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Idoso , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Estudos Prospectivos , Idoso de 80 Anos ou mais , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Fatores de Risco , Índice de Gravidade de Doença , Medição de Risco/métodos , Complicações Pós-Operatórias/epidemiologia , Tomografia Computadorizada por Raios X , Próteses Valvulares Cardíacas
16.
JACC Cardiovasc Interv ; 17(8): 979-988, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38658126

RESUMO

BACKGROUND: Symptomatic patients with severe aortic stenosis (AS) at high risk for surgical aortic valve replacement (SAVR) sustain comparable improvements in health status over 5 years after transcatheter aortic valve replacement (TAVR) or SAVR. Whether a similar long-term benefit is observed among intermediate-risk AS patients is unknown. OBJECTIVES: The purpose of this study was to assess health status outcomes through 5 years in intermediate risk patients treated with a self-expanding TAVR prosthesis or SAVR using data from the SURTAVI (Surgical Replacement and Transcatheter Aortic Valve Implantation) trial. METHODS: Intermediate-risk patients randomized to transfemoral TAVR or SAVR in the SURTAVI trial had disease-specific health status assessed at baseline, 30 days, and annually to 5 years using the Kansas City Cardiomyopathy Questionnaire (KCCQ). Health status was compared between groups using fixed effects repeated measures modelling. RESULTS: Of the 1,584 patients (TAVR, n = 805; SAVR, n = 779) included in the analysis, health status improved more rapidly after TAVR compared with SAVR. However, by 1 year, both groups experienced large health status benefits (mean change in KCCQ-Overall Summary Score (KCCQ-OS) from baseline: TAVR: 20.5 ± 22.4; SAVR: 20.5 ± 22.2). This benefit was sustained, albeit modestly attenuated, at 5 years (mean change in KCCQ-OS from baseline: TAVR: 15.4 ± 25.1; SAVR: 14.3 ± 24.2). There were no significant differences in health status between the cohorts at 1 year or beyond. Similar findings were observed in the KCCQ subscales, although a substantial attenuation of benefit was noted in the physical limitation subscale over time in both groups. CONCLUSIONS: In intermediate-risk AS patients, both transfemoral TAVR and SAVR resulted in comparable and durable health status benefits to 5 years. Further research is necessary to elucidate the mechanisms for the small decline in health status noted at 5 years compared with 1 year in both groups. (Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Severe, Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement [SURTAVI]; NCT01586910).


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Artéria Femoral , Nível de Saúde , Próteses Valvulares Cardíacas , Qualidade de Vida , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Feminino , Masculino , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Idoso , Idoso de 80 Anos ou mais , Fatores de Risco , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Medição de Risco , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Periférico/efeitos adversos , Punções , Desenho de Prótese
17.
JACC Cardiovasc Interv ; 17(8): 1007-1016, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38573257

RESUMO

BACKGROUND: Data on valve reintervention after transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) are limited. OBJECTIVES: The authors compared the 5-year incidence of valve reintervention after self-expanding CoreValve/Evolut TAVR vs SAVR. METHODS: Pooled data from CoreValve and Evolut R/PRO (Medtronic) randomized trials and single-arm studies encompassed 5,925 TAVR (4,478 CoreValve and 1,447 Evolut R/PRO) and 1,832 SAVR patients. Reinterventions were categorized by indication, timing, and treatment. The cumulative incidence of reintervention was compared between TAVR vs SAVR, Evolut vs CoreValve, and Evolut vs SAVR. RESULTS: There were 99 reinterventions (80 TAVR and 19 SAVR). The cumulative incidence of reintervention through 5 years was higher with TAVR vs SAVR (2.2% vs 1.5%; P = 0.017), with differences observed early (≤1 year; adjusted subdistribution HR: 3.50; 95% CI: 1.53-8.02) but not from >1 to 5 years (adjusted subdistribution HR: 1.05; 95% CI: 0.48-2.28). The most common reason for reintervention was paravalvular regurgitation after TAVR and endocarditis after SAVR. Evolut had a significantly lower incidence of reintervention than CoreValve (0.9% vs 1.6%; P = 0.006) at 5 years with differences observed early (adjusted subdistribution HR: 0.30; 95% CI: 0.12-0.73) but not from >1 to 5 years (adjusted subdistribution HR: 0.61; 95% CI: 0.21-1.74). The 5-year incidence of reintervention was similar for Evolut vs SAVR (0.9% vs 1.5%; P = 0.41). CONCLUSIONS: A low incidence of reintervention was observed for CoreValve/Evolut R/PRO and SAVR through 5 years. Reintervention occurred most often at ≤1 year for TAVR and >1 year for SAVR. Most early reinterventions were with the first-generation CoreValve and managed percutaneously. Reinterventions were more common following CoreValve TAVR compared with Evolut TAVR or SAVR.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Complicações Pós-Operatórias , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Incidência , Retratamento
18.
Artigo em Inglês | MEDLINE | ID: mdl-38836574

RESUMO

Background: Increased left atrial pressure (LAP) has been associated with adverse outcomes after mitral transcatheter edge-to-edge repair (M-TEER). We sought to evaluate outcomes based on differences in post-procedural LAP measured after final clip deployment. Methods: We included consecutive patients who underwent M-TEER at our institution between 2014-2022 with LAP monitoring. Patients were stratified into 3 groups according to tertiles of post-TEER mean LAP. Outcomes were assessed using Kaplan-Meier analysis and Cox proportional hazard models. Results: We included 273 patients (mean age 76.8±10.8 years, 42.5% women, 78.4% Caucasian). The mean post-TEER LAP was 8.7±1.7 mmHg in tertile 1 (N=85), 14.4±1.6 mmHg in tertile 2 (N=95), and 21.9±3.8 mmHg in tertile 3 (N=93). In comparison with tertile 1, both tertiles 2 and 3 were associated with increased risk of all-cause mortality or heart failure hospitalization at 2 years (adjHR 2.27, 95% CI 1.25-4.12; and adjHR 3.00, 95% CI 1.59-5.64 respectively). Among patients with primary MR, higher LAP was associated with increased risk of 2-year all-cause mortality or heart failure hospitalization [tertile 2 vs. 1: adjHR 3.00, 95% CI 1.37-6.56; and tertile 3 vs. 1: adjHR 5.52, 95% CI 2.04-14.95). However, in patients with secondary MR, neither being in tertile 2 (adjHR 1.53; 95% CI 0.55-4.24), nor tertile 3 (adjHR 2.18; 95% CI 0.82-5.77) were associated with the composite outcome compared with tertile 1. Any degree of LAP reduction following M-TEER was associated with lower mortality or heart failure hospitalization compared with no LAP reduction (adjHR 0.59; 95% CI 0.39-0.88). Conclusions: Elevated LAP after M-TEER was associated with increased 2-year risk of mortality or heart failure hospitalization. Exploration of reasons for elevated LAP after M-TEER, and ways to lower it warrant further investigation.

19.
Am J Cardiol ; 214: 1-7, 2024 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-38110018

RESUMO

Transcatheter aortic valve replacement (TAVR) provides an option for extreme-risk patients who underwent reoperation for a failed surgical aortic bioprosthesis. Long-term data on patients who underwent TAVR within a failed surgical aortic valve (TAV-in-SAV) are limited. The CoreValve Expanded Use Study evaluated patients at extreme surgical risk who underwent TAV-in-SAV. Outcomes at 5 years were analyzed by SAV failure mode (stenosis, regurgitation, or combined). Echocardiographic outcomes are site-reported. TAV-in-SAV was attempted in 226 patients with a mean age of 76.7 ± 10.8 years; 63.3% were male, the Society of Thoracic Surgeons predicted risk of mortality score was 9.0 ± 6.7%, and 87.5% had a New York Heart Association classification III or IV symptoms. Most of the failed surgical bioprostheses were stented (81.9%), with an average implant duration of 10.2 ± 4.3 years. The 5-year all-cause mortality or major stroke rate was 47.2% in all patients; 54.4% in the stenosis, 37.6% in the regurgitation, and 38.0% in the combined groups (p = 0.046). At 5 years, all-cause mortality was higher in patients with versus without 30-day severe prosthesis-patient mismatch (51.7% vs 38.3%, p = 0.026). The overall aortic valve reintervention rate was 5.9%; highest in the regurgitation group (12.6%). The mean aortic valve gradient was 14.1 ± 9.8 mm Hg and effective orifice area was 1.57 ± 0.70 at 5 years. Few patients had >mild paravalvular regurgitation at 5 years (5.5% moderate, 0.0% severe). TAV-in-SAV with supra-annular, self-expanding TAVR continues to represent a safe and lasting intermediate option for extreme-risk patients who have appropriate sizing of the preexisting failed surgical valve. Clinical and hemodynamic outcomes were stable through 5 years.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Seguimentos , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Instrumentos Cirúrgicos , Desenho de Prótese , Fatores de Risco
20.
J Am Heart Assoc ; 13(8): e033510, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38567665

RESUMO

BACKGROUND: Pulmonary hypertension (PH) and secondary mitral regurgitation (MR) are associated with adverse outcomes after mitral transcatheter edge-to-edge repair. We aim to study the prognostic value of invasively measured right ventricular afterload in patients undergoing mitral transcatheter edge-to-edge repair. METHODS AND RESULTS: We identified patients who underwent right heart catheterization ≤1 month before transcatheter edge-to-edge repair. The end points were all-cause mortality and a composite of mortality and heart failure hospitalization at 2 years. Using the receiver operating characteristic curve-derived threshold of 0.6 for pulmonary effective arterial elastance ([Ea], pulmonary artery systolic pressure/stroke volume), patients were stratified into 3 profiles based on PH severity (low elastance [HE]: Ea <0.6/mean pulmonary artery pressure (mPAP)) <35; High Elastance with No/Mild PH (HE-): Ea ≥0.6/mPAP <35; and HE with Moderate/Severe PH (HE+): Ea ≥0.6/mPAP ≥35) and MR pathogenesis (Primary MR [PMR])/low elastance, PMR/HE, and secondary MR). The association between this classification and clinical outcomes was examined using Cox regression. Among 114 patients included, 50.9% had PMR. Mean±SD age was 74.7±10.6 years. Patients with Ea ≥0.6 were more likely to have diabetes, atrial fibrillation, New York Heart Association III/IV status, and secondary MR (all P<0.05). Overall, 2-year cumulative survival was 71.1% and was lower in patients with secondary MR and mPAP ≥35. Compared with patients with low elastance, cumulative 2-year event-free survival was significantly lower in HE- and HE+ patients (85.5% versus 50.4% versus 41.0%, respectively, P=0.001). Also, cumulative 2-year event-free survival was significantly higher in patients with PMR/low elastance when compared with PMR/HE and patients with secondary mitral regurgitation (85.5% versus 55.5% versus 46.1%, respectively, P=0.005). CONCLUSIONS: Assessment of the preprocedural cardiopulmonary profile based on mPAP, MR pathogenesis, and Ea guides patient selection by identifying hemodynamic features that indicate likely benefit from mitral-transcatheter edge-to-edge repair in PH or lack thereof.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Prognóstico , Insuficiência da Valva Mitral/cirurgia , Hemodinâmica , Cateterismo Cardíaco/efeitos adversos , Artéria Pulmonar , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA