Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 277
Filtrar
1.
Eur Heart J ; 41(34): 3271-3279, 2020 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-31886479

RESUMO

Fractional flow reserve (FFR) and instantaneous wave-free ratio are the present standard diagnostic methods for invasive assessment of the functional significance of epicardial coronary stenosis. Despite the overall trend towards more physiology-guided revascularization, there remains a gap between guideline recommendations and the clinical adoption of functional evaluation of stenosis severity. A number of image-based approaches have been proposed to compute FFR without the use of pressure wire and induced hyperaemia. In order to better understand these emerging technologies, we sought to highlight the principles, diagnostic performance, clinical applications, practical aspects, and current challenges of computational physiology in the catheterization laboratory. Computational FFR has the potential to expand and facilitate the use of physiology for diagnosis, procedural guidance, and evaluation of therapies, with anticipated impact on resource utilization and patient outcomes.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Cateterismo Cardíaco , Angiografia Coronária , Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Índice de Gravidade de Doença
2.
Eur Heart J ; 39(35): 3314-3321, 2018 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-30137305

RESUMO

Aims: Pressure-wire assessment of coronary stenosis is considered the invasive reference standard for detection of ischaemia-generating lesions. Recently, methods to estimate the fractional flow reserve (FFR) from conventional angiography without the use of a pressure wire have been developed, and were shown to have an excellent diagnostic accuracy. The present systematic review and meta-analysis aimed at determining the diagnostic performance of angiography-derived FFR for the diagnosis of haemodynamically significant coronary artery disease. Methods and results: A systematic review and meta-analysis of studies assessing the diagnostic performance of angiography-derived FFR systems were performed. The primary outcome of interest was pooled sensitivity and specificity. Thirteen studies comprising 1842 vessels were included in the final analysis. A Bayesian bivariate meta-analysis yielded a pooled sensitivity of 89% (95% credible interval 83-94%), specificity of 90% (95% credible interval 88-92%), positive likelihood ratio (+LR) of 9.3 (95% credible interval 7.3-11.7) and negative likelihood ratio (-LR) of 0.13 (95% credible interval 0.07-0.2). The summary area under the receiver-operating curve was 0.84 (95% credible interval 0.66-0.94). Meta-regression analysis did not find differences between the methods for pressure-drop calculation (computational fluid dynamics vs. mathematical formula), type of analysis (on-line vs. off-line) or software packages. Conclusion: The accuracy of angiography-derived FFR was good to detect haemodynamically significant lesions with pressure-wire measured FFR as a reference. Computational approaches and software packages did not influence the diagnostic accuracy of angiography-derived FFR. A diagnostic strategy trial with angiography-derived FFR evaluating clinical endpoints is warranted.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico , Teorema de Bayes , Humanos , Sensibilidade e Especificidade
3.
J Nucl Cardiol ; 25(3): 860-871, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-28849416

RESUMO

Coronary artery disease is associated to high mortality and morbidity rates and an accurate diagnostic assessment during heart catheterization has a fundamental role in prognostic stratification and treatment choices. Coronary angiography has been integrated by intravascular imaging modalities, namely intravascular ultrasound and optical coherence tomography, which allow the precise quantification of the atherosclerotic burden of coronary arteries. The hemodynamic relevance of a given coronary stenosis can be assessed using stress or resting indexes: fractional flow reserve and instantaneous wave-free ratio are both coronary flow surrogates, used to guide percutaneous coronary interventions. This review summarizes the current state-of-the-art of invasive diagnostic methods during heart catheterization and highlights the potential role that an integration of anatomical and functional information enables.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Cateterismo Cardíaco , Angiografia Coronária , Doença da Artéria Coronariana/terapia , Reserva Fracionada de Fluxo Miocárdico , Humanos , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção
4.
Circ J ; 82(6): 1575-1583, 2018 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-29576586

RESUMO

BACKGROUND: Development of methods for accurate reconstruction of bioresorbable scaffolds (BRS) and assessing local hemodynamics is crucial for investigation of vascular healing after BRS implantation.Methods and Results:Patients with BRS that crossed over in a coronary bifurcation were included for analysis. Reconstructions of the coronary lumen and BRS were performed by fusion of optical coherence tomography and coronary angiography generating a tree model (TM) and a hybrid model with BRS (TM-BRS). A virtual BRS model with thinner struts was created and all 3 models were analyzed using computational fluid dynamics to derive: (1) time-average shear stress (TASS), (2) TASS gradient (TASSG), which represents SS heterogeneity, and (3) fractional flow reserve (FFR). Reconstruction of the BRS was successful in all 10 patients. TASS and TASSG were both higher by TM-BRS than by TM in main vessels (difference 0.27±4.30 Pa and 10.18±27.28 Pa/mm, P<0.001), with a remarkable difference at side branch ostia (difference 13.51±17.40 Pa and 81.65±105.19 Pa/mm, P<0.001). With thinner struts, TASS was lower on the strut surface but higher at the inter-strut zones, whereas TASSG was lower in both regions (P<0.001 for all). Computational FFR was lower by TM-BRS than by TM for both main vessels and side branches (P<0.001). CONCLUSIONS: Neglecting BRS reconstruction leads to significantly lower SS and SS heterogeneity, which is most pronounced at side branch ostia. Thinner struts can marginally reduce SS heterogeneity.


Assuntos
Implantes Absorvíveis , Hemodinâmica , Modelos Cardiovasculares , Alicerces Teciduais , Idoso , Angiografia Coronária/métodos , Vasos Coronários/cirurgia , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Masculino , Pessoa de Meia-Idade , Stents , Estresse Mecânico , Tomografia de Coerência Óptica/métodos , Cicatrização
5.
Eur J Nucl Med Mol Imaging ; 44(11): 1888-1896, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28685228

RESUMO

PURPOSE: A new method has been developed to calculate fractional flow reserve (FFR) from invasive coronary angiography, the so-called "contrast-flow quantitative flow ratio (cQFR)". Recently, cQFR was compared to invasive FFR in intermediate coronary lesions showing an overall diagnostic accuracy of 85%. The purpose of this study was to investigate the relationship between cQFR and myocardial ischemia assessed by single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI). METHODS: Patients who underwent SPECT MPI and coronary angiography within 3 months were included. The cQFR computation was performed offline, using dedicated software. The cQFR computation was based on 3-dimensional quantitative coronary angiography (QCA) and computational fluid dynamics. The standard 17-segment model was used to determine the vascular territories. Myocardial ischemia was defined as a summed difference score ≥2 in a vascular territory. A cQFR of ≤0.80 was considered abnormal. RESULTS: Two hundred and twenty-four coronary arteries were analysed in 85 patients. Overall accuracy of cQFR to detect ischemia on SPECT MPI was 90%. In multivariable analysis, cQFR was independently associated with ischemia on SPECT MPI (OR per 0.01 decrease of cQFR: 1.10; 95% CI 1.04-1.18, p = 0.002), whereas clinical and QCA parameters were not. Furthermore, cQFR showed incremental value for the detection of ischemia compared to clinical and QCA parameters (global chi square 48.7 to 62.6; p <0.001). CONCLUSIONS: A good relationship between cQFR and SPECT MPI was found. cQFR was independently associated with ischemia on SPECT MPI and showed incremental value to detect ischemia compared to clinical and QCA parameters.


Assuntos
Angiografia Coronária/métodos , Reserva Fracionada de Fluxo Miocárdico , Isquemia Miocárdica/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Angiografia Coronária/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Imagem de Perfusão do Miocárdio/normas , Tomografia Computadorizada de Emissão de Fóton Único/normas
6.
Catheter Cardiovasc Interv ; 90(1): E1-E10, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27567002

RESUMO

OBJECTIVES: To assess the anatomical and functional impact of final kissing balloon inflation (FKBI) after implantation of a dedicated bifurcation stent system. BACKGROUND: Current evidence suggests clinical benefit of FKBI in patients undergoing bifurcation dilatation using the Tryton side branch stent (Tryton-SBS). We hypothesized that FKBI improves anatomical reconstruction and functional results of bifurcation treated by Tryton-SBS. METHODS: An unselected group of patients with complex bifurcation coronary lesions undergoing percutaneous coronary intervention (PCI) with Tryton-SBS underwent paired anatomical assessment with two- and three-dimensional quantitative coronary analysis (2D- and 3D-QCA), and optical coherence tomography (OCT), including 3D reconstruction before and after FKBI. Functional assessment by fractional flow reserve (FFR) was performed in the main branch (MB) and side branch (SB) before and after FKBI. RESULTS: Paired pre- and post-FKBI data were obtained in 10 patients. By OCT imaging, FKBI increased both the SB ostial area (4.93 ± 2.81 vs. 7.43 ± 2.87 mm2 , P < 0.001) and the SB maximum diameter (3.12 ± 0.98 vs. 3.82 ± 1.10 mm, P = 0.003). These findings were associated with a significant increase in FFR in the SB (0.90 ± 0.05 vs. 0.94 ± 0.03; P = 0.011), with no significant change in the MB (0.91 ± 0.05 vs. 0.92 ± 0.04; P = 0.470). CONCLUSIONS: In patients with complex bifurcation stenosis undergoing PCI with a dedicated bifurcation system, FKBI is associated with improved anatomical and functional results at the SB level, without compromising the result at the MB. © 2016 Wiley Periodicals, Inc.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateterismo Cardíaco , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Imageamento Tridimensional , Interpretação de Imagem Radiográfica Assistida por Computador , Stents , Tomografia de Coerência Óptica , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/efeitos adversos , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento
7.
Magn Reson Med ; 74(1): 240-248, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25104100

RESUMO

PURPOSE: High field T2* -weighted MR images of the cerebral cortex are increasingly used to study tissue susceptibility changes related to aging or pathologies. This paper presents a novel automated method for the computation of quantitative cortical measures and group-wise comparison using 7 Tesla T2* -weighted magnitude and phase images. METHODS: The cerebral cortex was segmented using a combination of T2* -weighted magnitude and phase information and subsequently was parcellated based on an anatomical atlas. Local gray matter (GM)/white matter (WM) contrast and cortical profiles, which depict the magnitude or phase variation across the cortex, were computed from the magnitude and phase images in each parcellated region and further used for group-wise comparison. Differences in local GM/WM contrast were assessed using linear regression analysis. Regional cortical profiles were compared both globally and locally using permutation testing. The method was applied to compare a group of 10 young volunteers with a group of 15 older subjects. RESULTS: Using local GM/WM contrast, significant differences were revealed in at least 13 of 17 studied regions. Highly significant differences between cortical profiles were shown in all regions. CONCLUSION: The proposed method can be a useful tool for studying cortical changes in normal aging and potentially in neurodegenerative diseases. Magn Reson Med 74:240-248, 2015. © 2014 Wiley Periodicals, Inc.

8.
Circulation ; 127(17): 1793-800, 2013 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-23470859

RESUMO

BACKGROUND: Studies conducted decades ago described substantial disagreement and errors in physicians' angiographic interpretation of coronary stenosis severity. Despite the potential implications of such findings, no large-scale efforts to measure or improve clinical interpretation were subsequently undertaken. METHODS AND RESULTS: We compared clinical interpretation of stenosis severity in coronary lesions with an independent assessment using quantitative coronary angiography (QCA) in 175 randomly selected patients undergoing elective percutaneous coronary intervention at 7 US hospitals in 2011. To assess agreement, we calculated mean difference in percent diameter stenosis between clinical interpretation and QCA and a Cohen weighted κ statistic. Of 216 treated lesions, median percent diameter stenosis was 80.0% (quartiles 1 and 3, 80.0% and 90.0%), with 213 (98.6%) assessed as ≥70%. Mean difference in percent diameter stenosis between clinical interpretation and QCA was 8.2±8.4%, reflecting an average higher percent diameter stenosis by clinical interpretation (P<0.001). A weighted κ of 0.27 (95% confidence interval, 0.18-0.36) was found between the 2 measurements. Of 213 lesions considered ≥70% by clinical interpretation, 56 (26.3%) were <70% by QCA, although none were <50%. Differences between the 2 measurements were largest for intermediate lesions by QCA (50% to <70%), with variation existing across sites. CONCLUSIONS: Physicians tended to assess coronary lesions treated with percutaneous coronary intervention as more severe than measurements by QCA. Almost all treated lesions were ≥70% by clinical interpretation, whereas approximately one quarter were <70% by QCA. These findings suggest opportunities to improve clinical interpretation of coronary angiography.


Assuntos
Angiografia Coronária/normas , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/cirurgia , Intervenção Coronária Percutânea/normas , Índice de Gravidade de Doença , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
9.
J Magn Reson Imaging ; 39(3): 633-40, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23723108

RESUMO

PURPOSE: To develop a framework for quantitative detection of between-group textural differences in ultrahigh field T2*-weighted MR images of the brain. MATERIALS AND METHODS: MR images were acquired using a three-dimensional (3D) T2*-weighted gradient echo sequence on a 7 Tesla MRI system. The phase images were high-pass filtered to remove phase wraps. Thirteen textural features were computed for both the magnitude and phase images of a region of interest based on 3D Gray-Level Co-occurrence Matrix, and subsequently evaluated to detect between-group differences using a Mann-Whitney U-test. We applied the framework to study textural differences in subcortical structures between premanifest Huntington's disease (HD), manifest HD patients, and controls. RESULTS: In premanifest HD, four phase-based features showed a difference in the caudate nucleus. In manifest HD, 7 magnitude-based features showed a difference in the pallidum, 6 phase-based features in the caudate nucleus, and 10 phase-based features in the putamen. After multiple comparison correction, significant differences were shown in the putamen in manifest HD by two phase-based features (both adjusted P values=0.04). CONCLUSION: This study provides the first evidence of textural heterogeneity of subcortical structures in HD. Texture analysis of ultrahigh field T2*-weighted MR images can be useful for noninvasive monitoring of neurodegenerative diseases.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Doença de Huntington/patologia , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Adulto , Estudos de Casos e Controles , Feminino , Humanos , Doença de Huntington/diagnóstico , Masculino , Pessoa de Meia-Idade , Reconhecimento Automatizado de Padrão , Valores de Referência , Estatísticas não Paramétricas
10.
Circ J ; 78(8): 1873-81, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24942012

RESUMO

BACKGROUND: Quantitative light intensity analysis of the strut core by optical coherence tomography (OCT) may enable assessment of changes in the light reflectivity of the bioresorbable polymeric scaffold from polymer to provisional matrix and connective tissues, with full disappearance and integration of the scaffold into the vessel wall. The aim of this report was to describe the methodology and to apply it to serial human OCT images post procedure and at 6, 12, 24 and 36 months in the ABSORB cohort B trial. METHODS AND RESULTS: In serial frequency-domain OCT pullbacks, corresponding struts at different time points were identified by 3-dimensional foldout view. The peak and median values of light intensity were measured in the strut core by dedicated software. A total of 303 corresponding struts were serially analyzed at 3 time points. In the sequential analysis, peak light intensity increased gradually in the first 24 months after implantation and reached a plateau (relative difference with respect to baseline [%Dif]: 61.4% at 12 months, 115.0% at 24 months, 110.7% at 36 months), while the median intensity kept increasing at 36 months (%Dif: 14.3% at 12 months, 75.0% at 24 months, 93.1% at 36 months). CONCLUSIONS: Quantitative light intensity analysis by OCT was capable of detecting subtle changes in the bioresorbable strut appearance over time, and could be used to monitor the bioresorption and integration process of polylactide struts.


Assuntos
Implantes Absorvíveis , Prótese Vascular , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/cirurgia , Monitorização Fisiológica/métodos , Tomografia de Coerência Óptica , Estudos de Casos e Controles , Feminino , Seguimentos , Humanos , Masculino
11.
Int Psychogeriatr ; 26(7): 1067-81, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24524645

RESUMO

BACKGROUND: Clinical studies have shown that hippocampal atrophy is present before dementia in people with memory deficits and can predict dementia development. The question remains whether this association holds in the general population. This is of interest for the possible use of hippocampal atrophy to screen population for preventive interventions. The aim of this study was to assess hippocampal volume and shape abnormalities in elderly adults with memory deficits in a cross-sectional population-based study. METHODS: We included individuals participating in the Italian Project on the Epidemiology of Alzheimer Disease (IPREA) study: 75 cognitively normal individuals (HC), 31 individuals with memory deficits (MEM), and 31 individuals with memory deficits not otherwise specified (MEMnos). Hippocampal volumes and shape were extracted through manual tracing and the growing and adaptive meshes (GAMEs) shape-modeling algorithm. We investigated between-group differences in hippocampal volume and shape, and correlations with memory deficits. RESULTS: In MEM participants, hippocampal volumes were significantly smaller than in HC and were mildly associated with worse memory scores. Memory-associated shape changes mapped to the anterior hippocampus. Shape-based analysis detected no significant difference between MEM and HC, while MEMnos showed shape changes in the posterior hippocampus compared with HC and MEM groups. CONCLUSIONS: These findings support the discriminant validity of hippocampal volumetry as a biomarker of memory impairment in the general population. The detection of shape changes in MEMnos but not in MEM participants suggests that shape-based biomarkers might lack sensitivity to detect Alzheimer's-like pathology in the general population.


Assuntos
Hipocampo/patologia , Transtornos da Memória/patologia , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/diagnóstico , Doença de Alzheimer/patologia , Atrofia , Biomarcadores , Estudos Transversais , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Transtornos da Memória/diagnóstico , Neuroimagem , Tamanho do Órgão
12.
Artigo em Inglês | MEDLINE | ID: mdl-39018015

RESUMO

AIMS: Cardiac resynchronization therapy (CRT) may induce left ventricular (LV) reverse remodelling (=LV response) in patients with heart failure. Intraventricular pressure gradients can be quantified using echocardiography-derived haemodynamic forces (HDF). The aim was to evaluate the association between baseline HDF and LV response and to compare the change of HDF after CRT between LV responders and LV non-responders. METHODS AND RESULTS: The following HDF parameters were assessed: 1)apical-basal (AB) strength, 2)lateral-septal strength, 3)force vector angle, 4)systolic AB impulse, 5)systolic force vector angle. LV response was defined as a reduction of LV end-systolic volume ≥15% at six months. One hundred ninety-six patients were included (64±11 years, 122(62%) men), 136(69%) showed LV response. On multivariable logistic regression analysis, the force vector angle in the complete heart cycle (OR 1.083 (95%CI 1.018, 1.153), p=0.012) and the systolic force vector angle (OR 1.089 (95%CI 1.021, 1.161), p=0.009), both included in separate models, were independently associated with LV response. Six months after CRT, LV responders had greater AB strength, AB impulse and higher force vector angles, while LV non-responders only showed improvement in the force vector angle in the complete heart cycle. CONCLUSION: The orientation of HDF at baseline is associated with LV response to CRT. Six months after CRT, the orientation of HDF improves in LV responders and LV non-responders, while the magnitude of AB HDF only improves in LV responders.

13.
J Cardiovasc Comput Tomogr ; 18(2): 142-153, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38143234

RESUMO

BACKGROUND: Coronary computed tomography angiography (CCTA) analysis is currently performed by experts and is a laborious process. Fully automated edge-detection methods have been developed to expedite CCTA segmentation however their use is limited as there are concerns about their accuracy. This study aims to compare the performance of an automated CCTA analysis software and the experts using near-infrared spectroscopy-intravascular ultrasound imaging (NIRS-IVUS) as a reference standard. METHODS: Fifty-one participants (150 vessels) with chronic coronary syndrome who underwent CCTA and 3-vessel NIRS-IVUS were included. CCTA analysis was performed by an expert and an automated edge detection method and their estimations were compared to NIRS-IVUS at a segment-, lesion-, and frame-level. RESULTS: Segment-level analysis demonstrated a similar performance of the two CCTA analyses (conventional and automatic) with large biases and limits of agreement compared to NIRS-IVUS estimations for the total atheroma (ICC: 0.55 vs 0.25, mean difference:192 (-102-487) vs 243 (-132-617) and percent atheroma volume (ICC: 0.30 vs 0.12, mean difference: 12.8 (-5.91-31.6) vs 20.0 (0.79-39.2). Lesion-level analysis showed that the experts were able to detect more accurately lesions than the automated method (68.2 â€‹% and 60.7 â€‹%) however both analyses had poor reliability in assessing the minimal lumen area (ICC 0.44 vs 0.36) and the maximum plaque burden (ICC 0.33 vs 0.33) when NIRS-IVUS was used as the reference standard. CONCLUSIONS: Conventional and automated CCTA analyses had similar performance in assessing coronary artery pathology using NIRS-IVUS as a reference standard. Therefore, automated segmentation can be used to expedite CCTA analysis and enhance its applications in clinical practice.


Assuntos
Doença da Artéria Coronariana , Placa Aterosclerótica , Humanos , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Reprodutibilidade dos Testes , Ultrassonografia de Intervenção/métodos , Valor Preditivo dos Testes , Algoritmos , Vasos Coronários/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem
14.
EuroIntervention ; 20(9): 561-570, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38726719

RESUMO

BACKGROUND: Vessel-level physiological data derived from pressure wire measurements are one of the important determinant factors in the optimal revascularisation strategy for patients with multivessel disease (MVD). However, these may result in complications and a prolonged procedure time. AIMS: The feasibility of using the quantitative flow ratio (QFR), an angiography-derived fractional flow reserve (FFR), in Heart Team discussions to determine the optimal revascularisation strategy for patients with MVD was investigated. METHODS: Two Heart Teams were randomly assigned either QFR- or FFR-based data of the included patients. They then discussed the optimal revascularisation mode (percutaneous coronary intervention [PCI] or coronary artery bypass grafting [CABG]) for each patient and made treatment recommendations. The primary endpoint of the trial was the level of agreement between the treatment recommendations of both teams as assessed using Cohen's kappa. RESULTS: The trial included 248 patients with MVD from 10 study sites. Cohen's kappa in the recommended revascularisation modes between the QFR and FFR approaches was 0.73 [95% confidence interval {CI} : 0.62-0.83]. As for the revascularisation planning, agreements in the target vessels for PCI and CABG were substantial for both revascularisation modes (Cohen's kappa=0.72 [95% CI: 0.66-0.78] and 0.72 [95% CI: 0.66-0.78], respectively). The team assigned to the QFR approach provided consistent recommended revascularisation modes even after being made aware of the FFR data (Cohen's kappa=0.95 [95% CI:0.90-1.00]). CONCLUSIONS: QFR provided feasible physiological data in Heart Team discussions to determine the optimal revascularisation strategy for MVD. The QFR and FFR approaches agreed substantially in terms of treatment recommendations.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Humanos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Feminino , Masculino , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/diagnóstico por imagem , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Idoso , Ponte de Artéria Coronária/métodos , Tomada de Decisão Clínica , Cateterismo Cardíaco/métodos , Equipe de Assistência ao Paciente
15.
Am Heart J ; 166(6): 1010-1018.e1, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24268215

RESUMO

BACKGROUND: The purpose was to compare 3-dimensional quantitative coronary angiography (3D-QCA) with optical coherence tomography (OCT) for the functional assessment of nonobstructive coronary stenoses, as evaluated by fractional flow reserve (FFR). METHODS: Fifty-five nonobstructive coronary stenoses (30%-50% diameter stenosis by visual estimation) were assessed in 36 patients using FFR, 2-dimensional QCA (2D-QCA), 3D-QCA, and OCT. RESULTS: Angiographic stenosis severity by 2D-QCA was 34% ± 13% diameter stenosis, and minimal lumen diameter (MLD) was 1.77 ± 0.58 mm. Fractional flow reserve values were 0.85 ± 0.10. Correlation coefficients between FFR and MLD or minimal lumen area (MLA) were highly significant for both 2D- and 3D-QCA (all P < .001), but higher R(2) values were observed for 3D-QCA measurements. Although significant, correlation coefficients between OCT and FFR data were weak (R(2) = 0.28, P = .001 for MLD and R(2) = 0.23, P = .003 for MLA). Correlation coefficients with FFR were significantly higher for 3D-QCA than for OCT (P values for MLD and MLA = .043 and .042, respectively). Nonobstructive stenoses with MLD >1.53 mm or MLA >2.43 mm(2) are unlikely to be hemodynamically significant. CONCLUSIONS: In nonobstructive coronary stenoses, anatomical parameters derived from 3D-QCA can best identify lesions with preserved FFR values.


Assuntos
Cateterismo Cardíaco , Angiografia Coronária , Estenose Coronária/diagnóstico , Tomografia de Coerência Óptica , Idoso , Estenose Coronária/fisiopatologia , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença
16.
Catheter Cardiovasc Interv ; 81(6): E225-36, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-22707289

RESUMO

OBJECTIVES: This article presents the results of an interobserver validation study of our new T- and Y-shape bifurcation models including their edge segment analyses. BACKGROUND: Over the last years, the coronary artery intervention procedures have been developed more and more toward bifurcation stenting. Because traditional straight vessel quantitative coronary arteriography (QCA) is not sufficient for these measurements, the need has grown for new bifurcation analysis methods. METHODS: In this article, our two new bifurcation analysis models are presented, the Y-shape and T-shape model. These models were designed for the accurate measurement of the clinically relevant parameters of a coronary bifurcation, for different morphologies and intervention strategies and include an edge segment analysis, to accurately measure (drug-eluting) stent, stent edge, and ostial segment parameters. RESULTS: The results of an interobserver validation study of our T-shape and Y-shape analyses are presented, both containing the pre- and post-intervention analyses of each 10 cases. These results are associated with only small systematic and random errors, in the majority of the cases compliant with the QCA guidelines for straight analyses. The results for the edge segment analyses are also very good, with almost all the values within the margins that have been set by our brachytherapy directive. CONCLUSIONS: Our new bifurcation approaches including their edge segment analyses are very robust and reproducible, and therefore a great extension to the field of quantitative coronary angiography.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Modelos Cardiovasculares , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Algoritmos , Automação , Estenose Coronária/terapia , Humanos , Variações Dependentes do Observador , Intervenção Coronária Percutânea/instrumentação , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Stents , Resultado do Tratamento
17.
Eur Radiol ; 23(1): 115-24, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22782568

RESUMO

OBJECTIVES: Compared with X-ray coronary angiography (CAG), magnetic resonance imaging of the coronary vessel wall (MR-CVW) may provide more information about plaque burden and coronary remodelling. We compared MR-CVW with intravascular ultrasound (IVUS), the standard of reference for coronary vessel wall imaging, with regard to plaque detection and wall thickness measurements. METHODS: In this study 17 patients with chest pain, who had been referred for CAG, were included. Patients underwent IVUS and MR-CVW imaging of the right coronary artery (RCA). Subsequently, the coronary vessel wall was analysed for the presence and location of coronary plaques. RESULTS: Fifty-two matching RCA regions of interest were available for comparison. There was good agreement between IVUS and MR-CVW for qualitative assessment of presence of disease, with a sensitivity of 94% and specificity of 76%. Wall thickness measurements demonstrated a significant difference between mean wall thickness on IVUS and MR-CVW (0.48 vs 1.24 mm, P < 0.001), but great heterogeneity between wall thickness measurements, resulting in a low correlation between IVUS and MR-CVW. CONCLUSIONS: MR-CVW has high sensitivity for the detection of coronary vessel wall thickening in the RCA compared with IVUS. However, the use of MRI for accurate absolute wall thickness measurements is not supported when a longitudinal acquisition orientation is used.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Angiografia por Ressonância Magnética , Placa Aterosclerótica/diagnóstico , Ultrassonografia de Intervenção , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Placa Aterosclerótica/diagnóstico por imagem , Valor Preditivo dos Testes , Curva ROC , Sensibilidade e Especificidade
18.
Heart Vessels ; 28(2): 166-72, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22349692

RESUMO

Previous angiographic studies have shown that almost two-thirds of vulnerable plaques are located in non-obstructive lesions. Possibly, the maximum necrotic core (Max NC) area is not always identical to the site of most severe stenosis. Therefore, the purpose of this study was to evaluate the potential difference in location between the maximum necrotic core area and the site of most severe narrowing as assessed by virtual histology intravascular ultrasound (VH IVUS). Overall, 77 patients (139 vessels) underwent VH IVUS. The Max NC site was defined as the cross section with the largest necrotic core area per vessel. The site of most severe narrowing was defined as the minimum lumen area (MLA). Per vessel, the distance from both the Max NC site and MLA site to the origo of the coronary artery was evaluated. In addition, the presence of a virtual histology-thin cap fibroatheroma (VH-TCFA) was assessed. The mean difference (mm) between the MLA site and Max NC site was 10.8 ± 20.6 mm (p < 0.001). Interestingly, the Max NC site was located at the MLA site in seven vessels (5%) and proximally to the MLA site in 92 vessels (66%). Importantly, a higher percentage of VH-TCFA was demonstrated at the Max NC site as compared to the MLA site (24 vs. 9%, p < 0.001). In conclusion, the present findings demonstrate that the Max NC area is rarely at the site of most severe narrowing. Most often, the Max NC area is located proximal to the site of most severe narrowing.


Assuntos
Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Placa Aterosclerótica , Ultrassonografia de Intervenção , Idoso , Distribuição de Qui-Quadrado , Angiografia Coronária , Estenose Coronária/patologia , Vasos Coronários/patologia , Feminino , Fibrose , Humanos , Masculino , Pessoa de Meia-Idade , Necrose , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Índice de Gravidade de Doença , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/patologia
19.
Eur Heart J ; 33(8): 1007-16, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22285583

RESUMO

AIMS: Previous studies have used semi-automated approaches for coronary plaque quantification on multi-detector row computed tomography (CT), while an automated quantitative approach using a dedicated registration algorithm is currently lacking. Accordingly, the study aimed to demonstrate the feasibility and accuracy of automated coronary plaque quantification on cardiac CT using dedicated software with a novel 3D coregistration algorithm of CT and intravascular ultrasound (IVUS) data sets. METHODS AND RESULTS: Patients who had undergone CT and IVUS were enrolled. Automated lumen and vessel wall contour detection was performed for both imaging modalities. Dedicated automated quantitative software (QCT) with a unique registration algorithm was used to fuse a complete IVUS run with a CT angiography volume using true anatomical markers. At the level of the minimal lumen area (MLA), percentage lumen area stenosis, plaque burden, and degree of remodelling were obtained on CT. Additionally, mean plaque burden was assessed for the whole coronary plaque. At the identical level within the coronary artery, the same variables were derived from IVUS. Fifty-one patients (40 men, 58 ± 11 years, 103 coronary arteries) with 146 lesions were evaluated. Quantitative computed tomography and IVUS showed good correlation for MLA (n = 146, r = 0.75, P < 0.001). At the level of the MLA, both techniques were well-correlated for lumen area stenosis (n = 146, r = 0.79, P < 0.001) and plaque burden (n = 146, r = 0.70, P < 0.001). Mean plaque burden (n = 146, r = 0.64, P < 0.001) and remodelling index (n = 146, r = 0.56, P < 0.001) showed significant correlations between QCT and IVUS. CONCLUSION: Automated quantification of coronary plaque on CT is feasible using dedicated quantitative software with a novel 3D registration algorithm.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Placa Aterosclerótica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia de Intervenção/métodos , Idoso , Algoritmos , Estenose Coronária/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Calcificação Vascular/diagnóstico por imagem , Remodelação Ventricular/fisiologia
20.
Int J Cardiol ; 370: 442-444, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36395921

RESUMO

Hemodynamic force (HDF) analysis represents a novel approach to quantify intraventricular pressure gradients, responsible for blood flow. A new mathematical model allows the derivation of HDF parameters from routine transthoracic echocardiography, making this tool more accessible for clinical use. HDF analysis is considered the fluid dynamics correlate of deformation imaging and may be even more sensitive to detect mechanical abnormalities. This has the potential to add incremental clinical value, allowing earlier detection of pathology or immediate evaluation of response to treatment. In this article, the theoretical background and physiological patterns of HDF in the left ventricle are provided. In pathological situations, the HDF pattern might alter, which is illustrated with a case of ST segment elevation myocardial infarction and non-ischemic cardiomyopathy with typical left bundle branch block.


Assuntos
Ecocardiografia , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Ecocardiografia/métodos , Bloqueio de Ramo , Hemodinâmica , Ventrículos do Coração/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA