RESUMO
Isothermal nucleic acid amplification methods have many advantages for use at the point of care. However, there is a lack of multiplexed isothermal amplification tests to detect multiple targets in a single reaction, which would be valuable for many diseases, such as infection with high-risk human papillomavirus (hrHPV). In this study, we developed a multiplexed loop-mediated isothermal amplification (LAMP) reaction to detect the three most common hrHPV types that cause cervical cancer (HPV16, HPV18, and HPV45) and a cellular control for sample adequacy. First, we characterized the assay limit of detection (LOD) in a real-time reaction with fluorescence readout; after 30 min of amplification the LOD was 100, 10, and 10 copies/reaction of HPV16, HPV18, and HPV45, respectively, and 0.1 ng/reaction of human genomic DNA (gDNA). Next, we implemented the assay on lateral flow strips, and the LOD was maintained for HPV16 and HPV18, but increased to 100 copies/reaction for HPV45 and to 1 ng/reaction for gDNA. Lastly, we used the LAMP test to evaluate total nucleic acid extracted from 38 clinical samples; compared to qPCR, the LAMP test had 89% sensitivity and 95% specificity. When integrated with sample preparation, this multiplexed LAMP assay could be useful for point-of-care testing.
Assuntos
Papillomavirus Humano 18 , Infecções por Papillomavirus , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/diagnóstico , Papillomavirus Humano , Sensibilidade e Especificidade , Infecções por Papillomavirus/diagnóstico , Técnicas de Amplificação de Ácido Nucleico/métodos , Papillomavirus Humano 16/genética , Papillomaviridae/genética , DNA Viral/genéticaRESUMO
OBJECTIVES: As cervical cancer screening programs are implemented and expanded, an increasing number of women require loop electrosurgical excision procedure (LEEP) for treatment of pre-invasive cervical disease. Our objective was to describe the pathological results of LEEP specimens performed as part of the MULHER study and identify factors associated with positive LEEP margins. METHODS: The MULHER study enrolled 9014 women who underwent HPV testing followed by visual assessment for treatment (VAT) using visual inspection with acetic acid (VIA) and thermal ablation for those with positive results. Participants with lesions ineligible for ablation underwent LEEP. Pathology reports were reviewed for specimen size/volume, number of fragments, pathological diagnosis and margin status. Multivariable regression analysis was performed to identify variables associated with positive LEEP margins. RESULTS: 169 participants underwent LEEP. The median age was 38 years (range 30-49). 65.1% were women living with HIV. Pathological diagnosis was available for 154 patients and included cancer (n=6, 3.9%); cervical intraepithelial neoplasia (CIN) 2/3 (n=75, 48.7%); CIN 1 (n=67, 43.5%); and normal/benign findings (n=6,3.9%). 31.8% of LEEP specimens were removed in more than one fragment. The mean specimen volume was 2.9 cm3 (range 0.2-15.0). LEEP margin status was available for 130 patients. Positive margins (ectocervical/endocervical only, or both) were noted in 76 (58.5%) patients and associated with HIV+status (p=0.0499) and a diagnosis of CIN 2 or worse (p=0.0197). There were no associations between margin status and age, number of fragments or specimen volume. CONCLUSION: Our results showed a high number of LEEP specimens with positive margins. Additional evaluation is needed to better understand the characteristics of precancerous cervical lesions in this high-risk population. As cervical cancer screening programs are scaled in Mozambique and other lower-resource countries, there is a need to train providers to perform high-quality LEEP and for accurate and timely pathological interpretation.
RESUMO
BACKGROUND: The emergence of COVID-19 precipitated containment policies (e.g., lockdowns, school closures, etc.). These policies disrupted healthcare, potentially eroding gains for Sustainable Development Goals including for neonatal mortality. Our analysis aimed to evaluate indirect effects of COVID-19 containment policies on neonatal admissions and mortality in 67 neonatal units across Kenya, Malawi, Nigeria, and Tanzania between January 2019 and December 2021. METHODS: The Oxford Stringency Index was applied to quantify COVID-19 policy stringency over time for Kenya, Malawi, Nigeria, and Tanzania. Stringency increased markedly between March and April 2020 for these four countries (although less so in Tanzania), therefore defining the point of interruption. We used March as the primary interruption month, with April for sensitivity analysis. Additional sensitivity analysis excluded data for March and April 2020, modelled the index as a continuous exposure, and examined models for each country. To evaluate changes in neonatal admissions and mortality based on this interruption period, a mixed effects segmented regression was applied. The unit of analysis was the neonatal unit (n = 67), with a total of 266,741 neonatal admissions (January 2019 to December 2021). RESULTS: Admission to neonatal units decreased by 15% overall from February to March 2020, with half of the 67 neonatal units showing a decline in admissions. Of the 34 neonatal units with a decline in admissions, 19 (28%) had a significant decrease of ≥ 20%. The month-to-month decrease in admissions was approximately 2% on average from March 2020 to December 2021. Despite the decline in admissions, we found no significant changes in overall inpatient neonatal mortality. The three sensitivity analyses provided consistent findings. CONCLUSION: COVID-19 containment measures had an impact on neonatal admissions, but no significant change in overall inpatient neonatal mortality was detected. Additional qualitative research in these facilities has explored possible reasons. Strengthening healthcare systems to endure unexpected events, such as pandemics, is critical in continuing progress towards achieving Sustainable Development Goals, including reducing neonatal deaths to less than 12 per 1000 live births by 2030.
Assuntos
COVID-19 , Mortalidade Infantil , Análise de Séries Temporais Interrompida , Humanos , COVID-19/epidemiologia , COVID-19/prevenção & controle , COVID-19/mortalidade , Recém-Nascido , Tanzânia/epidemiologia , Quênia/epidemiologia , Mortalidade Infantil/tendências , Malaui/epidemiologia , Nigéria/epidemiologia , Admissão do Paciente/estatística & dados numéricos , Unidades de Terapia Intensiva Neonatal , Hospitalização/estatística & dados numéricos , Pandemias , LactenteRESUMO
BACKGROUND: Service readiness tools are important for assessing hospital capacity to provide quality small and sick newborn care (SSNC). Lack of summary scoring approaches for SSNC service readiness means we are unable to track national targets such as the Every Newborn Action Plan targets. METHODS: A health facility assessment (HFA) tool was co-designed by Newborn Essential Solutions and Technologies (NEST360) and UNICEF with four African governments. Data were collected in 68 NEST360-implementing neonatal units in Kenya, Malawi, Nigeria, and Tanzania (September 2019-March 2021). Two summary scoring approaches were developed: a) standards-based, including items for SSNC service readiness by health system building block (HSBB), and scored on availability and functionality, and b) level-2 + , scoring items on readiness to provide WHO level-2 + clinical interventions. For each scoring approach, scores were aggregated and summarised as a percentage and equally weighted to obtain an overall score by hospital, HSBB, and clinical intervention. RESULTS: Of 1508 HFA items, 1043 (69%) were included in standards-based and 309 (20%) in level-2 + scoring. Sixty-eight neonatal units across four countries had median standards-based scores of 51% [IQR 48-57%] at baseline, with variation by country: 62% [IQR 59-66%] in Kenya, 49% [IQR 46-51%] in Malawi, 50% [IQR 42-58%] in Nigeria, and 55% [IQR 53-62%] in Tanzania. The lowest scoring was family-centred care [27%, IQR 18-40%] with governance highest scoring [76%, IQR 71-82%]. For level-2 + scores, the overall median score was 41% [IQR 35-51%] with variation by country: 50% [IQR 44-53%] in Kenya, 41% [IQR 35-50%] in Malawi, 33% [IQR 27-37%] in Nigeria, and 41% [IQR 32-52%] in Tanzania. Readiness to provide antibiotics by culture report was the highest-scoring intervention [58%, IQR 50-75%] and neonatal encephalopathy management was the lowest-scoring [21%, IQR 8-42%]. In both methods, overall scores were low (< 50%) for 27 neonatal units in standards-based scoring and 48 neonatal units in level-2 + scoring. No neonatal unit achieved high scores of > 75%. DISCUSSION: Two scoring approaches reveal gaps in SSNC readiness with no neonatal units achieving high scores (> 75%). Government-led quality improvement teams can use these summary scores to identify areas for health systems change. Future analyses could determine which items are most directly linked with quality SSNC and newborn outcomes.
Assuntos
Instalações de Saúde , Hospitais , Recém-Nascido , Humanos , Tanzânia , Malaui , Quênia , Nigéria , Organização Mundial da SaúdeRESUMO
BACKGROUND: Each year an estimated 2.3 million newborns die in the first 28 days of life. Most of these deaths are preventable, and high-quality neonatal care is fundamental for surviving and thriving. Service readiness is used to assess the capacity of hospitals to provide care, but current health facility assessment (HFA) tools do not fully evaluate inpatient small and sick newborn care (SSNC). METHODS: Health systems ingredients for SSNC were identified from international guidelines, notably World Health Organization (WHO), and other standards for SSNC. Existing global and national service readiness tools were identified and mapped against this ingredients list. A novel HFA tool was co-designed according to a priori considerations determined by policymakers from four African governments, including that the HFA be completed in one day and assess readiness across the health system. The tool was reviewed by > 150 global experts, and refined and operationalised in 64 hospitals in Kenya, Malawi, Nigeria, and Tanzania between September 2019 and March 2021. RESULTS: Eight hundred and sixty-six key health systems ingredients for service readiness for inpatient SSNC were identified and mapped against four global and eight national tools measuring SSNC service readiness. Tools revealed major content gaps particularly for devices and consumables, care guidelines, and facility infrastructure, with a mean of 13.2% (n = 866, range 2.2-34.4%) of ingredients included. Two tools covered 32.7% and 34.4% (n = 866) of ingredients and were used as inputs for the new HFA tool, which included ten modules organised by adapted WHO health system building blocks, including: infrastructure, pharmacy and laboratory, medical devices and supplies, biomedical technician workshop, human resources, information systems, leadership and governance, family-centred care, and infection prevention and control. This HFA tool can be conducted at a hospital by seven assessors in one day and has been used in 64 hospitals in Kenya, Malawi, Nigeria, and Tanzania. CONCLUSION: This HFA tool is available open-access to adapt for use to comprehensively measure service readiness for level-2 SSNC, including respiratory support. The resulting facility-level data enable comparable tracking for Every Newborn Action Plan coverage target four within and between countries, identifying facility and national-level health systems gaps for action.
Assuntos
Países em Desenvolvimento , Qualidade da Assistência à Saúde , Recém-Nascido , Humanos , Nações Unidas , Tanzânia , Instalações de SaúdeRESUMO
OBJECTIVE: To evaluate cervical cancer screening with primary human papillomavirus (HPV) testing in Mozambique, a country with one of the highest burdens of cervical cancer globally. METHODS: Women aged 30-49 years were prospectively enrolled and offered primary HPV testing using either self-collected or provider-collected specimens. Patients who tested positive for HPV underwent visual assessment for treatment using visual inspection with acetic acid to determine eligibility for thermal ablation. If ineligible, they were referred for excision with a loop electrosurgical excision procedure, for cold knife conization, or for cervical biopsy if malignancy was suspected. RESULTS: Between January 2020 and January 2023, 9014 patients underwent cervical cancer screening. Median age was 37 years (range 30-49) and 4122 women (45.7%) were patients living with HIV. Most (n=8792, 97.5%) chose self-collection. The HPV positivity rate was 31.1% overall and 39.5% among patients living with HIV. Of the 2805 HPV-positive patients, 2588 (92.3%) returned for all steps of their diagnostic work-up and treatment, including ablation (n=2383, 92.1%), loop electrosurgical excision procedure (n=169, 6.5%), and cold knife conization (n=5, 0.2%). Thirty-one patients (1.2%) were diagnosed with cancer and referred to gynecologic oncology. CONCLUSION: It is feasible to perform cervical cancer screening with primary HPV testing and follow-up in low-resource settings. Participants preferred self-collection, and the majority of screen-positive patients completed all steps of their diagnostic work-up and treatment. Our findings provide important information for further implementation and scale-up of cervical cancer screening and treatment services as part of the WHO global strategy for the elimination of cervical cancer.
Assuntos
Infecções por HIV , Infecções por Papillomavirus , Displasia do Colo do Útero , Neoplasias do Colo do Útero , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Neoplasias do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/cirurgia , Neoplasias do Colo do Útero/prevenção & controle , Infecções por Papillomavirus/diagnóstico , Detecção Precoce de Câncer/métodos , Moçambique/epidemiologia , Papillomaviridae , Programas de Rastreamento/métodos , Infecções por HIV/diagnósticoRESUMO
BACKGROUND: Millions of newborns die annually from preventable causes, with the highest rates occurring in Africa. Reducing neonatal mortality requires investment to scale hospital care, which includes providing hospitals with appropriate technology to care for small and sick newborns. Expensive medical devices designed for high-resource settings often fail to withstand conditions in low-resource hospitals, including humidity, dust, frequent user turnover, complex maintenance, lack of stable power, or difficulty sourcing expensive consumables. Rigorous evaluation protocols are needed to identify effective, affordable, rugged, and easy-to-use medical devices appropriate for quality hospital-based newborn care in low-resource hospitals. METHODS: We developed an evidence-based technology review process to identify medical devices suitable for small and sick newborn care in low-resource hospitals. The eight-step process consists of: identifying devices needed for effective newborn care; defining Target Product Profiles (TPPs); identifying commercially-available products that may meet TPPs; conducting desk research to evaluate technologies against TPPs; performing technical performance verification testing under laboratory conditions; verifying technical performance after exposure to heat, humidity, dust, and power loss; performing usability evaluations with nurses, and qualifying devices that pass all steps. Devices were purchased, installed, and monitored in newborn wards across Kenya, Malawi, Nigeria, and Tanzania. RESULTS: Of 271 devices considered, only 45 (16.6%) met corresponding TPPs based on desk research. Thirty-nine were purchased and evaluated in the laboratory; five (12.8%) failed to meet TPPs. Thirty-four products passing laboratory evaluation underwent short-term environmental testing; only one (2.9%) device failed. Thirty-seven products underwent usability testing with 127 clinicians; surprisingly, 14 (37.8%) failed to meet TPPs. Twenty-three products passed all evaluations, and 2457 devices were installed across 65 newborn wards in Kenya, Malawi, Nigeria, and Tanzania. Continuous device monitoring reported minimal device failures, with failed devices typically returned to service within two days, resulting in an average uptime (service days divided by days installed) of 99%. CONCLUSION: An evidence-based device selection process can improve procurement of effective, affordable, rugged, usable newborn care devices for low-resource hospitals, and feedback to manufacturers can improve device quality. Similar processes could be adapted beyond newborn care to identify medical devices suitable for implementation in any low-resource setting.
Assuntos
Cemitérios , Hospitais , Recém-Nascido , Humanos , Mortalidade Infantil , Quênia , PoeiraRESUMO
BACKGROUND: Small and sick newborn care (SSNC) is critical for national neonatal mortality reduction targets by 2030. Investment cases could inform implementation planning and enable coordinated resource mobilisation. We outline development of an investment case for Tanzania to estimate additional financing for scaling up SSNC to 80% of districts as part of health sector strategies to meet the country's targets. METHODS: We followed five steps: (1) reviewed national targets, policies and guidelines; (2) modelled potential health benefits by increased coverage of SSNC using the Lives Saved Tool; (3) estimated setup and running costs using the Neonatal Device Planning and Costing Tool, applying two scenarios: (A) all new neonatal units and devices with optimal staffing, and (B) half new and half modifying, upgrading, or adding resources to existing neonatal units; (4) calculated budget impact and return on investment (ROI) and (5) identified potential financing opportunities. RESULTS: Neonatal mortality rate was forecast to fall from 20 to 13 per 1000 live births with scale-up of SSNC, superseding the government 2025 target of 15, and close to the 2030 Sustainable Development Goal 3.2 target of <12. At 85% endline coverage, estimated cumulative lives saved were 36,600 by 2025 and 80,000 by 2030. Total incremental costs were estimated at US$166 million for scenario A (US$112 million set up and US$54 million for running costs) and US$90 million for scenario B (US$65 million setup and US$25 million for running costs). Setup costs were driven by infrastructure (83%) and running costs by human resources (60%). Cost per capita was US$0.93 and the ROI is estimated to be between US$8-12 for every dollar invested. CONCLUSIONS: ROI for SSNC is higher compared to other health investments, noting many deaths averted followed by full lifespan. This is conservative since disability averted is not included. Budget impact analysis estimated a required 2.3% increase in total government health expenditure per capita from US$40.62 in 2020, which is considered affordable, and the government has already allocated additional funding. Our proposed five-step SSNC investment case has potential for other countries wanting to accelerate progress.
Assuntos
Mortalidade Infantil , Desenvolvimento Sustentável , Recém-Nascido , Humanos , TanzâniaRESUMO
BACKGROUND: Medical devices are critical to providing high-quality, hospital-based newborn care, yet many of these devices are unavailable in low- and middle-income countries (LMIC) and are not designed to be suitable for these settings. Target Product Profiles (TPPs) are often utilised at an early stage in the medical device development process to enable user-defined performance characteristics for a given setting. TPPs can also be applied to assess the profile and match of existing devices for a given context. METHODS: We developed initial TPPs for 15 newborn product categories for LMIC settings. A Delphi-like process was used to develop the TPPs. Respondents completed an online survey where they scored their level of agreement with each of the proposed performance characteristics for each of the 15 devices. Characteristics with < 75% agreement between respondents were discussed and voted on using Mentimeter™ at an in-person consensus meeting. FINDINGS: The TPP online survey was sent to 180 people, of which 103 responded (57%). The majority of respondents were implementers/clinicians (51%, 53/103), with 50% (52/103) from LMIC. Across the 15 TPPs, 403 (60%) of the 668 performance characteristics did not achieve > 75% agreement. Areas of disagreement were voted on by 69 participants at an in-person consensus meeting, with consensus achieved for 648 (97%) performance characteristics. Only 20 (3%) performance characteristics did not achieve consensus, most (15/20) relating to quality management systems. UNICEF published the 15 TPPs in April 2020, accompanied by a report detailing the online survey results and consensus meeting discussion, which has been viewed 7,039 times (as of January 2023). CONCLUSIONS: These 15 TPPs can inform developers and enable implementers to select neonatal care products for LMIC. Over 2,400 medical devices and diagnostics meeting these TPPs have been installed in 65 hospitals in Nigeria, Tanzania, Kenya, and Malawi through the NEST360 Alliance. Twenty-three medical devices identified and qualified by NEST360 meet nearly all performance characteristics across 11 of the 15 TPPs. Eight of the 23 qualified medical devices are available in the UNICEF Supply Catalogue. Some developers have adjusted their technologies to meet these TPPs. There is potential to adapt the TPP process beyond newborn care.
Assuntos
Nações Unidas , Recém-Nascido , Humanos , Quênia , Malaui , Nigéria , TanzâniaRESUMO
BACKGROUND: High-quality neonatal care requires sufficient functional medical devices, furniture, fixtures, and use by trained healthcare workers, however there is lack of publicly available tools for quantification and costing. This paper describes development and use of a planning and costing tool regarding furniture, fixtures and devices to support scale-up of WHO level-2 neonatal care, for national and global newborn survival targets. METHODS: We followed a systematic process. First, we reviewed planning and costing tools of relevance. Second, we co-designed a new tool to estimate furniture and device set-up costs for a default 40-bed level-2 neonatal unit, incorporating input from multi-disciplinary experts and newborn care guidelines. Furniture and device lists were based off WHO guidelines/norms, UNICEF and national manuals/guides. Due to lack of evidence-based quantification, ratios were based on operational manuals, multi-country facility assessment data, and expert opinion. Default unit costs were from government procurement agency costs in Kenya, Nigeria, and Tanzania. Third, we refined the tool by national use in Tanzania. RESULTS: The tool adapts activity-based costing (ABC) to estimate quantities and costs to equip a level-2 neonatal unit based on three components: (1) furniture/fixtures (18 default but editable items); (2) neonatal medical devices (16 product categories with minimum specifications for use in low-resource settings); (3) user training at device installation. The tool was used in Tanzania to generate procurement lists and cost estimates for level-2 scale-up in 171 hospitals (146 District and 25 Regional Referral). Total incremental cost of all new furniture and equipment acquisition, installation, and user training were US$93,000 per District hospital (level-2 care) and US$346,000 per Regional Referral hospital. Estimated cost per capita for whole-country district coverage was US$0.23, representing 0.57% increase in government health expenditure per capita and additional 0.35% for all Regional Referral hospitals. CONCLUSION: Given 2.3 million neonatal deaths and potential impact of level-2 newborn care, rational and efficient planning of devices linked to systems change is foundational. In future iterations, we aim to include consumables, spare parts, and maintenance cost options. More rigorous implementation research data are crucial to formulating evidence-based ratios for devices numbers per baby. Use of this tool could help overcome gaps in devices numbers, advance efficiency and quality of neonatal care.
Assuntos
Decoração de Interiores e Mobiliário , Morte Perinatal , Lactente , Recém-Nascido , Feminino , Humanos , Tanzânia , Quênia , NigériaRESUMO
BACKGROUND: Every Newborn Action Plan (ENAP) coverage target 4 necessitates national scale-up of Level-2 Small and Sick Newborn Care (SSNC) (with Continuous Positive Airway Pressure (CPAP)) in 80% of districts by 2025. Routine neonatal inpatient data is important for improving quality of care, targeting equity gaps, and enabling data-driven decision-making at individual, district, and national-levels. Existing neonatal inpatient datasets vary in purpose, size, definitions, and collection processes. We describe the co-design and operationalisation of a core inpatient dataset for use to track outcomes and improve quality of care for small and sick newborns in high-mortality settings. METHODS: A three-step systematic framework was used to review, co-design, and operationalise this novel neonatal inpatient dataset in four countries (Malawi, Kenya, Tanzania, and Nigeria) implementing with the Newborn Essential Solutions and Technologies (NEST360) Alliance. Existing global and national datasets were identified, and variables were mapped according to categories. A priori considerations for variable inclusion were determined by clinicians and policymakers from the four African governments by facilitated group discussions. These included prioritising clinical care and newborn outcomes data, a parsimonious variable list, and electronic data entry. The tool was designed and refined by > 40 implementers and policymakers during a multi-stakeholder workshop and online interactions. RESULTS: Identified national and international datasets (n = 6) contained a median of 89 (IQR:61-154) variables, with many relating to research-specific initiatives. Maternal antenatal/intrapartum history was the largest variable category (21, 23.3%). The Neonatal Inpatient Dataset (NID) includes 60 core variables organised in six categories: (1) birth details/maternal history; (2) admission details/identifiers; (3) clinical complications/observations; (4) interventions/investigations; (5) discharge outcomes; and (6) diagnosis/cause-of-death. Categories were informed through the mapping process. The NID has been implemented at 69 neonatal units in four African countries and links to a facility-level quality improvement (QI) dashboard used in real-time by facility staff. CONCLUSION: The NEST360 NID is a novel, parsimonious tool for use in routine information systems to inform inpatient SSNC quality. Available on the NEST360/United Nations Children's Fund (UNICEF) Implementation Toolkit for SSNC, this adaptable tool enables facility and country-level comparisons to accelerate progress toward ENAP targets. Additional linked modules could include neonatal at-risk follow-up, retinopathy of prematurity, and Level-3 intensive care.
Assuntos
Países em Desenvolvimento , Pacientes Internados , Criança , Recém-Nascido , Gravidez , Humanos , Feminino , Qualidade da Assistência à Saúde , Parto , TanzâniaRESUMO
Microscopic evaluation of resected tissue plays a central role in the surgical management of cancer. Because optical microscopes have a limited depth-of-field (DOF), resected tissue is either frozen or preserved with chemical fixatives, sliced into thin sections placed on microscope slides, stained, and imaged to determine whether surgical margins are free of tumor cells-a costly and time- and labor-intensive procedure. Here, we introduce a deep-learning extended DOF (DeepDOF) microscope to quickly image large areas of freshly resected tissue to provide histologic-quality images of surgical margins without physical sectioning. The DeepDOF microscope consists of a conventional fluorescence microscope with the simple addition of an inexpensive (less than $10) phase mask inserted in the pupil plane to encode the light field and enhance the depth-invariance of the point-spread function. When used with a jointly optimized image-reconstruction algorithm, diffraction-limited optical performance to resolve subcellular features can be maintained while significantly extending the DOF (200 µm). Data from resected oral surgical specimens show that the DeepDOF microscope can consistently visualize nuclear morphology and other important diagnostic features across highly irregular resected tissue surfaces without serial refocusing. With the capability to quickly scan intact samples with subcellular detail, the DeepDOF microscope can improve tissue sampling during intraoperative tumor-margin assessment, while offering an affordable tool to provide histological information from resected tissue specimens in resource-limited settings.
Assuntos
Carcinoma/patologia , Aprendizado Profundo , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Bucais/patologia , Algoritmos , Animais , Biópsia/instrumentação , Biópsia/métodos , Biópsia/normas , Calibragem , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Processamento de Imagem Assistida por Computador/normas , Microscopia de Fluorescência/instrumentação , Microscopia de Fluorescência/métodos , Microscopia de Fluorescência/normas , SuínosRESUMO
We conducted a prospective evaluation of the diagnostic performance of high-resolution microendoscopy (HRME) to detect cervical intraepithelial neoplasia (CIN) in women with abnormal screening tests. Study participants underwent colposcopy, HRME and cervical biopsy. The prospective diagnostic performance of HRME using an automated morphologic image analysis algorithm was compared to that of colposcopy using histopathologic detection of CIN as the gold standard. To assess the potential to further improve performance of HRME image analysis, we also conducted a retrospective analysis assessing performance of a multi-task convolutional neural network to segment and classify HRME images. One thousand four hundred eighty-six subjects completed the study; 435 (29%) subjects had CIN Grade 2 or more severe (CIN2+) diagnosis. HRME with morphologic image analysis for detection of CIN Grade 3 or more severe diagnoses (CIN3+) was similarly sensitive (95.6% vs 96.2%, P = .81) and specific (56.6% vs 58.7%, P = .18) as colposcopy. HRME with morphologic image analysis for detection of CIN2+ was slightly less sensitive (91.7% vs 95.6%, P < .01) and specific (59.7% vs 63.4%, P = .02) than colposcopy. Images from 870 subjects were used to train a multi-task convolutional neural network-based algorithm and images from the remaining 616 were used to validate its performance. There were no significant differences in the sensitivity and specificity of HRME with neural network analysis vs colposcopy for detection of CIN2+ or CIN3+. Using a neural network-based algorithm, HRME has comparable sensitivity and specificity to colposcopy for detection of CIN2+. HRME could provide a low-cost, point-of-care alternative to colposcopy and biopsy in the prevention of cervical cancer.
Assuntos
Histeroscopia/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Displasia do Colo do Útero/diagnóstico por imagem , Adulto , Idoso , Brasil , Colposcopia , Sistemas Computacionais , Feminino , Humanos , Microtecnologia , Pessoa de Meia-Idade , Redes Neurais de Computação , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos , Sensibilidade e Especificidade , Adulto JovemRESUMO
Cervical cancer remains a leading cause of cancer death for women in low- and middle-income countries. The goal of our study was to evaluate screening and triage strategies, including high-resolution microendoscopy (HRME), to detect cervical abnormalities concerning for precancer at the point of care. Women (n = 1824) were enrolled at the Instituto de Cáncer de El Salvador. All underwent screening by both human papillomavirus (HPV) testing using careHPV and visual inspection with acetic acid (VIA). Screen-positives, along with 10% of screen-negatives, were invited to return for a follow-up examination that included triage with VIA, colposcopy and HRME imaging. Biopsies were taken of any abnormalities identified. If no abnormalities were identified, then the worst scoring site by HRME was biopsied. The sensitivities of HPV testing and VIA to screen for cervical intraepithelial neoplasia Grade 2 or more severe diagnoses (CIN2+) were 82.1% and 75% (P = .77), while the specificities were 90.4% and 80.9% (P < .001), respectively. The sensitivities of VIA, colposcopy and HRME as triage tests for CIN2+ were 82.1%, 82.1% and 71.4%, respectively (P ≥ .38). HRME had a significantly higher specificity (66.7%) than VIA (51.9%) (P < .001) and colposcopy (53.3%) (P < .001). When evaluating different theoretical screening and triage strategies, screening with HPV testing followed by triage with HRME would result in more women receiving appropriate care (97%) compared to screening with VIA (75%) or HPV alone (90%). Our findings demonstrate that screening with HPV is superior to VIA, and that triage with HRME imaging increases the specificity of detecting CIN2+ at the point of care in a low-resource setting.
RESUMO
Sickle cell disease (SCD) is a group of common, life-threatening disorders caused by a point mutation in the ß globin gene. Early diagnosis through newborn and early childhood screening, parental education, and preventive treatments are known to reduce mortality. However, the cost and complexity of conventional diagnostic methods limit the feasibility of early diagnosis for SCD in resource-limited areas worldwide. Although several point-of-care tests are commercially available, most are antibody-based tests, which cannot be used in patients who have recently received a blood transfusion. Here, we describe the development of a rapid, low-cost nucleic acid test that uses real-time fluorescence to detect the point mutation encoding hemoglobin S (HbS) in one round of isothermal recombinase polymerase amplification (RPA). When tested with a set of clinical samples from SCD patients and healthy volunteers, our assay demonstrated 100% sensitivity for both the ßA globin and ßS globin alleles and 94.7 and 97.1% specificities for the ßA globin allele and ßS globin allele, respectively (n = 91). Finally, we demonstrate proof-of-concept sample-to-answer genotyping of genomic DNA from capillary blood using an alkaline lysis procedure and direct input of diluted lysate into RPA. The workflow is performed in <30 min at a cost of <$5 USD on a commercially available benchtop fluorimeter and an open-source miniature fluorimeter. This study demonstrates the potential utility of a rapid, sample-to-answer nucleic acid test for SCD that may be implemented near the point of care and could be adapted to other disease-causing point mutations in genomic DNA.
Assuntos
Anemia Falciforme , Recombinases , Alelos , Anemia Falciforme/diagnóstico , Anemia Falciforme/genética , Pré-Escolar , Hemoglobina Falciforme/análise , Humanos , Recém-Nascido , Técnicas de Amplificação de Ácido Nucleico , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e EspecificidadeRESUMO
BACKGROUND AND AIMS: High-resolution microendoscopy (HRME) is an optical biopsy technology that provides subcellular imaging of esophageal mucosa but requires expert interpretation of these histopathology-like images. We compared endoscopists with an automated software algorithm for detection of esophageal squamous cell neoplasia (ESCN) and evaluated the endoscopists' accuracy with and without input from the software algorithm. METHODS: Thirteen endoscopists (6 experts, 7 novices) were trained and tested on 218 post-hoc HRME images from 130 consecutive patients undergoing ESCN screening/surveillance. The automated software algorithm interpreted all images as neoplastic (high-grade dysplasia, ESCN) or non-neoplastic. All endoscopists provided their interpretation (neoplastic or non-neoplastic) and confidence level (high or low) without and with knowledge of the software overlay highlighting abnormal nuclei and software interpretation. The criterion standard was histopathology consensus diagnosis by 2 pathologists. RESULTS: The endoscopists had a higher mean sensitivity (84.3%, standard deviation [SD] 8.0% vs 76.3%, P = .004), lower specificity (75.0%, SD 5.2% vs 85.3%, P < .001) but no significant difference in accuracy (81.1%, SD 5.2% vs 79.4%, P = .26) of ESCN detection compared with the automated software algorithm. With knowledge of the software algorithm, the specificity of the endoscopists increased significantly (75.0% to 80.1%, P = .002) but not the sensitivity (84.3% to 84.8%, P = .75) or accuracy (81.1% to 83.1%, P = .13). The increase in specificity was among novices (P = .008) but not experts (P = .11). CONCLUSIONS: The software algorithm had lower sensitivity but higher specificity for ESCN detection than endoscopists. Using computer-assisted diagnosis, the endoscopists maintained high sensitivity while increasing their specificity and accuracy compared with their initial diagnosis. Automated HRME interpretation would facilitate widespread usage in resource-poor areas where this portable, low-cost technology is needed.
Assuntos
Esôfago , Neoplasias , Células Epiteliais , Esofagoscopia , Esôfago/diagnóstico por imagem , Humanos , Sensibilidade e Especificidade , SoftwareRESUMO
Oral cancer causes significant global mortality and has a five-year survival rate of around 64%. Poor prognosis results from late-stage diagnosis, highlighting an important need to develop better approaches to detect oral premalignant lesions (OPLs) and identify which OPLs are at highest risk of progression to oral squamous cell carcinoma (OSCC). An appropriate animal model that reflects the genetic, histologic, immunologic, molecular and gross visual features of human OSCC would aid in the development and evaluation of early detection and risk assessment strategies. Here, we present an experimental PIK3CA + 4NQO transgenic mouse model of oral carcinogenesis that combines the PIK3CA oncogene mutation with oral exposure to the chemical carcinogen 4NQO, an alternate experimental transgenic mouse model with PIK3CA as well as E6 and E7 mutations, and an existing wild-type mouse model based on oral exposure to 4NQO alone. We compare changes in dorsal and ventral tongue gross visual appearance, histologic features and molecular biomarker expression over a time course of carcinogenesis. Both transgenic models exhibit cytological and architectural features of dysplasia that mimic human disease and exhibit slightly increased staining for Ki-67, a cell proliferation marker. The PIK3CA + 4NQO model additionally exhibits consistent lymphocytic infiltration, presents with prominent dorsal and ventral tongue tumours, and develops cancer quickly relative to the other models. Thus, the PIK3CA + 4NQO model recapitulates the multistep genetic model of human oral carcinogenesis and host immune response in carcinogen-induced tongue cancer, making it a useful resource for future OSCC studies.
Assuntos
Transformação Celular Neoplásica/induzido quimicamente , Transformação Celular Neoplásica/genética , Classe I de Fosfatidilinositol 3-Quinases/genética , Mutação , Quinolonas , Carcinoma de Células Escamosas de Cabeça e Pescoço/induzido quimicamente , Carcinoma de Células Escamosas de Cabeça e Pescoço/genética , Neoplasias da Língua/induzido quimicamente , Neoplasias da Língua/genética , 4-Nitroquinolina-1-Óxido , Animais , Proliferação de Células , Transformação Celular Neoplásica/patologia , Modelos Animais de Doenças , Progressão da Doença , Linfócitos/patologia , Camundongos Endogâmicos CBA , Camundongos Transgênicos , Proteínas Oncogênicas Virais/genética , Carcinoma de Células Escamosas de Cabeça e Pescoço/patologia , Fatores de Tempo , Neoplasias da Língua/patologiaRESUMO
AIM: This study evaluated whether peer mentorship was an effective and sustainable way of improving and maintaining knowledge and skills on neonatal continuous positive airway pressure (CPAP) in a low-resource setting with a high turnover of healthcare providers. METHODS: The Malawi Ministry of Health recruited five nurses with considerable CPAP experience and provided them with mentorship training from July to August 2014. The mentors then provided 1-week on-site mentorship for 113 colleagues at 10 secondary and one tertiary hospital where gaps in neonatal CPAP use had been identified. CPAP competencies and outcomes were compared 3 months before and after each mentorship. RESULTS: In the 3 months before and after mentorship, the average CPAP competency score increased from 32 ± 4% to 97 ± 2%, while CPAP usage increased from 7% to 23% among eligible neonates. Survival following CPAP mentorship increased from 23% to 35%, but this was not significant due to the small sample size. Both mentees and mentors reported useful transfers of knowledge and skills when using CPAP. CONCLUSION: Mentorship effectively bridged the knowledge and skills gaps among health workers and increased CPAP use, competency scores and survival rates.
Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Mentores , Pessoal de Saúde , Humanos , Recém-Nascido , Malaui , Centros de Atenção TerciáriaRESUMO
Newborns are at increased risk of jaundice, a condition in which excess bilirubin accumulates in blood. Left untreated, jaundice can lead to neurological impairment and death. Jaundice resulting from unconjugated hyperbilirubinemia is easily treated with exposure to blue light, and phototherapy systems have been developed for low-resource settings; however, there are no appropriate solutions to diagnose and monitor jaundice in these settings. To address this need we present BiliSpec, a low-cost reader and disposable lateral flow card designed to measure the concentration of total bilirubin from several drops of blood at the point of care. We evaluated the performance of BiliSpec, using blood from normal volunteers spiked with varying amounts of bilirubin; results measured using BiliSpec correlated well with a reference laboratory bilirubinometer (r = 0.996). We then performed a pilot clinical study using BiliSpec to measure total bilirubin in neonates at risk for jaundice at Queen Elizabeth Central Hospital in Blantyre, Malawi. Concentrations measured using BiliSpec correlated well with those measured using a laboratory reference standard in 94 patient samples ranging from 1.1 mg/dL to 23.0 mg/dL in concentration (r = 0.973). The mean difference between bilirubin levels measured with BiliSpec and the reference standard was 0.3 mg/dL (95[Formula: see text] CI: -1.7-2.2 mg/dL).
Assuntos
Icterícia Neonatal/diagnóstico , Testes Imediatos , Feminino , Recursos em Saúde , Humanos , Recém-Nascido , Malaui , Masculino , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Reprodutibilidade dos TestesRESUMO
Line-scanning confocal microendoscopy offers video-rate cellular imaging of scattering tissue with relatively simple hardware, but its axial response is inferior to that of point-scanning systems. Based on Fourier optics theory, we designed differential confocal apertures with a simple subtraction technique to improve the line-scanning sectioning performance. Taking advantage of digital slit apertures on a digital light projector and a CMOS rolling shutter, we demonstrate real-time optical sectioning performance comparable to point scanning in a dual-camera microendoscope (<$6,000). We validate the background rejection capability when imaging porcine columnar epithelium stained with fluorescent contrast agents with different uptake mechanisms and staining properties.