RESUMO
Photonic mechanical sensors offer several advantages over their electronic counterparts, including immunity to electromagnetic interference, increased sensitivity, and measurement accuracy. Exploring flexible mechanical sensors on deformable substrates provides new opportunities for strain-optical coupling operations. Nevertheless, existing flexible photonics strategies often require cumbersome signal collection and analysis with bulky setups, limiting their portability and affordability. To address these challenges, we propose a waveguide-integrated flexible mechanical sensor based on cascaded photonic crystal microcavities with inherent deformation and biaxial tensile state analysis. Leveraging the advanced multiplexing capability of the sensor, for the first time, we successfully demonstrate 2D shape reconstruction and quasi-distributed strain sensing with 110 µm spatial resolution. Our microscale mechanical sensor also exhibits exceptional sensitivity with a detected force level as low as 13.6 µN in real-time measurements. This sensing platform has potential applications in various fields, including biomedical sensing, surgical catheters, aircraft and spacecraft engineering, and robotic photonic skin development.
RESUMO
Flexible integrated photonics is a rapidly emerging technology with a wide range of possible applications in the fields of flexible optical interconnects, conformal multiplexing sensing, health monitoring, and biotechnology. One major challenge in developing mechanically flexible integrated photonics is the functional component within an integrated photonic circuit with superior performance. In this work, several essential flexible passive devices for such a circuit were designed and fabricated based on a multi-neutral-axis mechanical design and a monolithic integration technique. The propagation loss of the waveguide is calculated to be 4.2â dB/cm. In addition, we demonstrate a microring resonator, waveguide crossing, multimode interferometer (MMI), and Mach-Zehnder interferometer (MZI) for use at 1.55 µm, each exhibiting superior optical and mechanical performance. These results represent a significant step towards further exploring a complete flexible photonic integrated circuit.
RESUMO
Metasurfaces have shown promising potentials in shaping optical wavefronts while remaining compact compared to bulky geometric optics devices. The design of meta-atoms, the fundamental building blocks of metasurfaces, typically relies on trial and error to achieve target electromagnetic responses. This process includes the characterization of an enormous amount of meta-atom designs with varying physical and geometric parameters, which demands huge computational resources. In this paper, a deep learning-based metasurface/meta-atom modeling approach is introduced to significantly reduce the characterization time while maintaining accuracy. Based on a convolutional neural network (CNN) structure, the proposed deep learning network is able to model meta-atoms with nearly freeform 2D patterns and different lattice sizes, material refractive indices and thicknesses. Moreover, the presented approach features the capability of predicting a meta-atom's wide spectrum response in the timescale of milliseconds, attractive for applications necessitating fast on-demand design and optimization of a meta-atom/metasurface.
RESUMO
We report on the design, fabrication and testing of three types of coupling structures for hybrid chalcogenide glass Ge23Sb7S70-Silicon (GeSbS-Si) photonic integrated circuit platforms. The first type is a fully etched GeSbS grating coupler defined directly in the GeSbS film. Coupling losses of 5.3 dB and waveguide-to-waveguide back-reflections of 3.4% were measured at a wavelength of 1553 nm. Hybrid GeSbS-to-Si butt couplers and adiabatic couplers transmitting light between GeSbS and Si single-mode waveguides were further developed. The hybrid butt couplers (HBCs) feature coupling losses of 2.7 dB and 9.2% back-reflection. The hybrid adiabatic couplers (HACs) exhibit coupling losses of 0.7 dB and negligible back-reflection. Both HBCs and HACs have passbands exceeding the 100 nm measurement range of the test setup. GeSbS grating couplers and GeSbS-to-Si waveguide couplers can be co-fabricated in the same process flow, providing, for example, a means to first couple high optical power levels required for nonlinear signal processing directly into GeSbS waveguides and to later transition into Si waveguides after attenuation of the pump. Moreover, GeSbS waveguides and HBC transitions have been fabricated on post-processed silicon photonics chips obtained from a commercially available foundry service, with a previously deposited 2 µm thick top waveguide cladding. This fabrication protocol demonstrates the compatibility of the developed integration scheme with standard silicon photonics technology with a complete back-end-of-line process.
RESUMO
We demonstrated a class of highly nonlinear hybrid waveguide structures based on infiltration of As2S3 chalcogenide glass into silicon slot waveguides. The nonlinear properties of the hybrid waveguides were precisely quantified via a bidirectional top-hat D-scan method, enabling a direct comparison between properties measured using different device geometries. We experimentally demonstrate hybrid As2S3-Si slot waveguides with a two-photon absorption (TPA) figure of merit exceeding 2 at near infrared wavelengths. These waveguides largely satisfy the critical criterion for efficient nonlinear integrated photonics (FOMTPAwg>1), allowing phase shifts greater than π with minimal overall losses. These results pave the way for efficient and robust ultrafast all-optical devices and circuits in large-scale silicon photonics technology.
RESUMO
Low propagation loss Ge23Sb7S70 waveguides (0.56 dB/cm) are fabricated in a wafer scale process. Simulation of a 2 cm long, 1.2 µm wide waveguide with 100 ps/nm/km peak dispersion predicts coherent supercontinuum generation at 1.55 µm pump wavelength. Octave-spanning supercontinuum using a dispersive wave is experimentally demonstrated using picojoule-level energy (26 pJ, 240 fs pulse width, 77 W peak power) pulses.
RESUMO
Programmable and reconfigurable optics hold significant potential for transforming a broad spectrum of applications, spanning space explorations to biomedical imaging, gas sensing, and optical cloaking. The ability to adjust the optical properties of components like filters, lenses, and beam steering devices could result in dramatic reductions in size, weight, and power consumption in future optoelectronic devices. Among the potential candidates for reconfigurable optics, chalcogenide-based phase change materials (PCMs) offer great promise due to their non-volatile and analogue switching characteristics. Although PCM have found widespread use in electronic data storage, these memory devices are deeply sub-micron-sized. To incorporate phase change materials into free-space optical components, it is essential to scale them up to beyond several hundreds of microns while maintaining reliable switching characteristics. This study demonstrated a non-mechanical, non-volatile transmissive filter based on low-loss PCMs with a 200 × 200 µm2 switching area. The device/metafilter can be consistently switched between low- and high-transmission states using electrical pulses with a switching contrast ratio of 5.5 dB. The device was reversibly switched for 1250 cycles before accelerated degradation took place. The work represents an important step toward realizing free-space reconfigurable optics based on PCMs.
RESUMO
Ge-Sb-Se-Te chalcogenides, namely Se-substituted Ge-Sb-Te, have been developed as an alternative optical phase change material (PCM) with a high figure-of-merit. A need for the integration of such new PCMs onto a variety of photonic platforms has necessitated the development of fabrication processes compatible with diverse material compositions as well as substrates of varying material types, shapes, and sizes. This study explores the application of chemical solution deposition as a method capable of creating conformally coated layers and delves into the resulting modifications in the structural and optical properties of Ge-Sb-Se-Te PCMs. Specifically, we detail the solution-based deposition of Ge-Sb-Se-Te layers and present a comparative analysis with those deposited via thermal evaporation. We also discuss our ongoing endeavor to improve available choice of processing-material combinations and how to realize solution-derived high figure-of-merit optical PCM layers, which will enable a new era for the development of reconfigurable photonic devices.
RESUMO
BACKGROUND: The Army Combat Fitness Test (ACFT) is a performance assessment used by the U.S. Army to assess a cadet's strength, endurance, and agility with a series of six events to ensure that cadets are combat ready. Heart rate variability (HRV) is an instrument that measures cardiac autonomic modulation and has been incorporated to predict the performance of athletes in daily training and competition since acute bouts of exercise alter HRV variables. PURPOSE: To assess the applicability of using HRV to predict ACFT score performance outcomes in cadets. METHODS: Fifty army cadets (n = 36 male; n = 14 female; age = 20.60 ± 3.61 years; height = 173.34 ± 10.39 cm; body mass = 76.33 ± 14.68 kg; body fat percentage = 17.58 ± 5.26%) completed the ACFT and reported for HRV assessment. HRV assessment had the participant lay supine for 5 minutes, and traditional time and frequency domain variables were assessed. A Pearson's correlation and multiple linear regressions were run. RESULTS: HRV time and frequency domains were not significantly correlated in linear regression models except the stress index (SI) and the 2-mile run (2MR). The standing power throw and sprint drag carry were significantly correlated with traditional HRV variables. CONCLUSIONS: HRV was not a predictor of ACFT performance for individual events or overall ACFT. The SI presented predictive properties only for 2MR, with no other significant correlations between HRV variables with standing power throw and sprint drag carry. The SI ability to predict 2MR performance outcome via HRV is a promising tool to assess army cadet performance and recovery.
RESUMO
Aerobic exercise, specifically high-intensity interval exercise (HIIE), and its effects on renal health and filtration (RHF) are not well understood. Several studies support incorporating contemporary biomarkers serum cystatin C (CyC) and urine epidermal growth factor (uEGF) to combat the volatility of serum creatinine (sCr). Using these biomarkers, we examined the acute influences HIIE has on RHF to determine if there is a ceiling effect in healthy populations. The purpose was to determine the influence of an acute bout of HIIE on RHF. Thirty-six participants (n = 22 males; n = 14 females; age 37.6 ± 12.4 years.; BF% 19.2 ± 7.1%; VO2max 41.8 + 7.4 mL/kg/min) completed 30 min of HIIE on a treadmill (80% and 40% of VO2reserve in 3:2 min ratio). Blood and urine samples were obtained under standardized conditions before, 1 h, and 24 h post-exercise. CyC, sCR, uEGF, urine creatinine (uCr), uCr/uEGF ratio, and multiple estimates of glomerular filtration rate (eGFR) Modification of Diet in Renal Disease (MDRD) and CKD-EPI equations were used. The analysis employed paired sample t-tests and repeated measures ANOVAs. CyC, uEGF, uCr, and uCr/uEGF ratio concentrations were not altered between timepoints. sCr increased 1 h post-exercise (p > 0.002) but not at 24 h post-exercise. eGFR decreased in the MDRD and CKD-EPI equations at 1 h (p > 0.012) with no changes at 24 h post-exercise. CyC and sCr/CyC demonstrated no significant changes. CyC and uEGF are not altered by acute HIIE. The results demonstrate a potential ceiling effect in contemporary and traditional biomarkers of RHF, indicating improvements in RHF may be isolated to populations with reduced kidney function.
RESUMO
Phase Change Materials (PCMs) have demonstrated tremendous potential as a platform for achieving diverse functionalities in active and reconfigurable micro-nanophotonic devices across the electromagnetic spectrum, ranging from terahertz to visible frequencies. This comprehensive roadmap reviews the material and device aspects of PCMs, and their diverse applications in active and reconfigurable micro-nanophotonic devices across the electromagnetic spectrum. It discusses various device configurations and optimization techniques, including deep learning-based metasurface design. The integration of PCMs with Photonic Integrated Circuits and advanced electric-driven PCMs are explored. PCMs hold great promise for multifunctional device development, including applications in non-volatile memory, optical data storage, photonics, energy harvesting, biomedical technology, neuromorphic computing, thermal management, and flexible electronics.
RESUMO
[This corrects the article DOI: 10.1016/j.isci.2023.107946.].
RESUMO
Introduction: Hyperuricemia commonly associated with Gout has been proposed as an independent risk factor for Metabolic Syndrome (MetS). Objective: The purpose of the study was to determine if there is a relationship between hyperuricemia and MetS. Methods: An analysis of cross-sectional data was conducted using the 2013-2018 National Health and Nutrition Examination Survey (NHANES) datasets. Sample weights were assigned by NHANES researchers to each participant allowing researchers to generalize results to all non-institutionalized United States (US) civilians. The analysis included 6,432 individuals, which were representative of 94,729,059 US citizens. Results: Pearson's correlations, chi-square tests, and logistic regression equations were calculated to determine the association between hyperuricemia and MetS. In an unadjusted regression analysis, individuals with hyperuricemia (above 7.0 mg/dL in males and 6.0 mg/dL in females) were 3.19 times more likely to have MetS compared to those with normal uric acid (UA) levels. When controlling for various confounding variables those with hyperuricemia were 1.89 and 1.34 times more likely to have MetS than those with normal UA levels in two additional logistic regression models. Conclusion: In this large cross-sectional study, hyperuricemia was found to be associated with MetS. Additional analyses that controlled for various risk factors previously identified as predictive of MetS still demonstrated hyperuricemia independently associated with MetS. The results of this study suggest a need to understand the metabolic pathways of UA more clearly to further explain the contribution to MetS. Additional research should include prospective clinical trials assessing the effects of UA and the control of UA on MetS and concomitant medical outcomes.
RESUMO
Aerobic exercise elicits a multitude of physiological improvements in both healthy and diseased populations. However, acute changes in renal health and filtration with aerobic exercise remain difficult to quantify by traditional biomarkers to estimate glomerular filtration rate (eGFR). This study aimed to determine if an acute bout of moderate-intensity aerobic exercise transiently improves non-traditional biomarkers when compared to traditional biomarkers of renal health and filtration in individuals without cardiometabolic diseases. Thirty-nine participants (n = 18 men; n = 21 women; age 32.5 + 12.6 yr; height 171.1 + 11.4 cm; weight 78.7 + 15.6 kg; BMI 27.1 + 5.8) completed a single bout of moderate-intensity (50-60% HRR) aerobic exercise. Blood and urine samples were collected and compared before and post-exercise. Serum creatinine, urine epidermal growth factor (uEGF), uEGF/urine creatinine ratio (uEGFR), and cystatin C (CyC) were measured. In addition, eGFR-MDRD and the CKD-epidemiology equations were used to analyze renal clearance. Relative to pre-exercise measures: serum creatinine (p = 0.26), uEGF (p = 0.35), and uEGFR (p = 0.09) remained unchanged, whereas cystatin C (p = 0.00) significantly increased post-exercise. CyC eGFR was the only estimator of renal filtration to significantly change (p = 0.04). In conclusion, CyC is the only biomarker of renal health and filtration to significantly increase after aerobic exercise. Further investigation focused on sampling time and exercise-intensity is needed to solidify the current understanding of renal health and filtration.
RESUMO
The development of compact and fieldable mid-infrared (mid-IR) spectroscopy devices represents a critical challenge for distributed sensing with applications from gas leak detection to environmental monitoring. Recent work has focused on mid-IR photonic integrated circuit (PIC) sensing platforms and waveguide-integrated mid-IR light sources and detectors based on semiconductors such as PbTe, black phosphorus and tellurene. However, material bandgaps and reliance on SiO2 substrates limit operation to wavelengths λ â² 4 µm. Here we overcome these challenges with a chalcogenide glass-on-CaF2 PIC architecture incorporating split-gate photothermoelectric graphene photodetectors. Our design extends operation to λ = 5.2 µm with a Johnson noise-limited noise-equivalent power of 1.1 nW/Hz1/2, no fall-off in photoresponse up to f = 1 MHz, and a predicted 3-dB bandwidth of f3dB > 1 GHz. This mid-IR PIC platform readily extends to longer wavelengths and opens the door to applications from distributed gas sensing and portable dual comb spectroscopy to weather-resilient free space optical communications.
RESUMO
Maximal oxygen consumption (VO2max) has been associated with body fat percentage (%BF) or fat free mass. However, most analyses do not consider total body composition (TBC) as defined by %BF, fat free mass index (FFMIa height-adjusted measure of muscle mass), visceral adipose tissue, and bone mineral content (BMC). The aim of this study was to determine if TBC predicts cardiorespiratory fitness in healthy adults and if a relationship exists in young and older adults. Sixty healthy individuals (age group 1 (AG1, ≤35 years), n = 35; age group 2 (AG2, >35 years), n = 25) were screened in a cross-sectional study and retrospectively examined. All participants completed a full body DEXA scan and a standardized multistage treadmill test to determine VO2max. A multiple linear regression analysis was performed to examine the relationship between TBC and VO2max. The multiple regression model showed an overall significant effect for TBC (p < 0.001, R2 = 0.282). When analyzed by age group, the regression model of TBC was not significant in young adults (AG1, p = 0.319, R2 = 0.141), but significant in older adults (AG2, p < 0.001, R2 = 0.683). Significant predictors of VO2max in the older cohort were %BF (ß = −0.748, p = 0.001) and BMC (ß = 0.014, p = 0.002). Total body composition predicted VO2max in a small cohort of healthy adults. This study highlights the importance of TBC for cardiovascular health, especially in mid-to later-life individuals.
Assuntos
Aptidão Cardiorrespiratória , Adulto , Idoso , Composição Corporal/fisiologia , Índice de Massa Corporal , Aptidão Cardiorrespiratória/fisiologia , Estudos Transversais , Humanos , Consumo de Oxigênio , Aptidão Física/fisiologia , Projetos Piloto , Estudos Retrospectivos , Adulto JovemRESUMO
Active metasurfaces promise reconfigurable optics with drastically improved compactness, ruggedness, manufacturability and functionality compared to their traditional bulk counterparts. Optical phase-change materials (PCMs) offer an appealing material solution for active metasurface devices with their large index contrast and non-volatile switching characteristics. Here we report a large-scale, electrically reconfigurable non-volatile metasurface platform based on optical PCMs. The optical PCM alloy used in the devices, Ge2Sb2Se4Te (GSST), uniquely combines giant non-volatile index modulation capability, broadband low optical loss and a large reversible switching volume, enabling notably enhanced light-matter interactions within the active optical PCM medium. Capitalizing on these favourable attributes, we demonstrated quasi-continuously tuneable active metasurfaces with record half-octave spectral tuning range and large optical contrast of over 400%. We further prototyped a polarization-insensitive phase-gradient metasurface to realize dynamic optical beam steering.
RESUMO
Active metasurfaces, whose optical properties can be modulated post-fabrication, have emerged as an intensively explored field in recent years. The efforts to date, however, still face major performance limitations in tuning range, optical quality, and efficiency, especially for non-mechanical actuation mechanisms. In this paper, we introduce an active metasurface platform combining phase tuning in the full 2π range and diffraction-limited performance using an all-dielectric, low-loss architecture based on optical phase change materials (O-PCMs). We present a generic design principle enabling binary switching of metasurfaces between arbitrary phase profiles and propose a new figure-of-merit (FOM) tailored for reconfigurable meta-optics. We implement the approach to realize a high-performance varifocal metalens operating at 5.2 µm wavelength. The reconfigurable metalens features a record large switching contrast ratio of 29.5 dB. We further validate aberration-free and multi-depth imaging using the metalens, which represents a key experimental demonstration of a non-mechanical tunable metalens with diffraction-limited performance.
RESUMO
GeSbS ridge waveguides have recently been demonstrated as a promising mid - infrared platform for integrated waveguide - based chemical sensing and photodetection. To date, their nonlinear optical properties remain relatively unexplored. In this paper, we characterize the nonlinear optical properties of GeSbS glasses, and show negligible nonlinear losses at 1.55 µm. Using self - phase modulation experiments, we characterize a waveguide nonlinear parameter of 7 W-1/m and nonlinear refractive index of 3.71 × 10-18 m2/W. GeSbS waveguides are used to generate supercontinuum from 1280 nm to 2120 nm at the -30 dB level. The spectrum expands along the red shifted side of the spectrum faster than on the blue shifted side, facilitated by cascaded stimulated Raman scattering arising from the large Raman gain of chalcogenides. Fourier transform infrared spectroscopic measurements show that these glasses are optically transparent up to 25 µm, making them useful for short - wave to long - wave infrared applications in both linear and nonlinear optics.
RESUMO
A chip-scale mid-IR water sensor was developed using silicon nitride (SiN) waveguides coated with poly(glycidyl methacrylate) (PGMA). The label-free detection was conducted at λ=2.6-2.7 µm because this spectral region overlaps with the characteristic O-H stretch absorption while being transparent to PGMA and SiN. Through the design of a hybrid waveguide structure, we were able to tailor the mid-IR evanescent wave into the PGMA layer and the surrounding water and, consequently, to enhance the light-analyte interaction. A 7.6 times enhancement of sensitivity is experimentally demonstrated and explained by material integration engineering as well as waveguide mode analysis. Our sensor platform made by polymer-dielectric hybrids can be applied to other regions of the mid-IR spectrum to probe other analytes and can ultimately achieve a multispectral sensor on-a-chip.