Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
EMBO J ; 39(4): e102363, 2020 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-31957048

RESUMO

Navigation of sperm in fluid flow, called rheotaxis, provides long-range guidance in the mammalian oviduct. The rotation of sperm around their longitudinal axis (rolling) promotes rheotaxis. Whether sperm rolling and rheotaxis require calcium (Ca2+ ) influx via the sperm-specific Ca2+ channel CatSper, or rather represent passive biomechanical and hydrodynamic processes, has remained controversial. Here, we study the swimming behavior of sperm from healthy donors and from infertile patients that lack functional CatSper channels, using dark-field microscopy, optical tweezers, and microfluidics. We demonstrate that rolling and rheotaxis persist in CatSper-deficient human sperm. Furthermore, human sperm undergo rolling and rheotaxis even when Ca2+ influx is prevented. Finally, we show that rolling and rheotaxis also persist in mouse sperm deficient in both CatSper and flagellar Ca2+ -signaling domains. Our results strongly support the concept that passive biomechanical and hydrodynamic processes enable sperm rolling and rheotaxis, rather than calcium signaling mediated by CatSper or other mechanisms controlling transmembrane Ca2+ flux.


Assuntos
Hidrodinâmica , Motilidade dos Espermatozoides , Espermatozoides/fisiologia , Animais , Fenômenos Biomecânicos , Cálcio/metabolismo , Canais de Cálcio/genética , Canais de Cálcio/metabolismo , Sinalização do Cálcio , Humanos , Masculino , Camundongos , Proteínas de Plasma Seminal/genética , Proteínas de Plasma Seminal/metabolismo
2.
J Chem Phys ; 148(20): 204110, 2018 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-29865845

RESUMO

The suppression of Raman scattering is of high interest for the achievement of sub-diffraction-limited resolution in Raman scattering spectroscopy and microscopy. We present density matrix calculations of the suppression of spontaneous Raman scattering via ground state depletion in a level system based on the molecule tris(bipyridine)ruthenium(ii). This particular molecule has been earlier used for an experimental demonstration of the suppression of spontaneous Raman scattering, allowing us to successfully verify the validity of our numerical calculations by a comparison to the experimental results. We investigate the required level of detail of the molecule model as well as the influence of certain molecule and pulse parameters on the Raman scattering suppression. It was found that pulses with a duration longer than the lifetime of the electronic states allow for a high suppression of the Raman scattering. Pulses shorter than the coherence lifetime between the ground state and electronic states lead to a similarly high suppression but also accomplish the suppression with more than one order of magnitude lower pulse energy fluence. Additionally, using a laser wavelength that is in resonance with one of the electronic transitions of the sample should allow suppressing the Raman scattering with four to six orders of magnitude lower pulse energy fluence.

3.
Opt Express ; 24(18): 20745-54, 2016 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-27607677

RESUMO

We report on the first experimental demonstration of the suppression of spontaneous Raman scattering via ground state depletion. The concept of Raman suppression can be used to achieve sub-diffraction-limited resolution in label-free microscopy by exploiting spatially selective signal suppression when imaging a sample with a combination of Gaussian- and donut-shaped beams and reconstructing a resolution-enhanced image from this data. Using a nanosecond pulsed laser source with an emission wavelength of 355 nm, the ground state of tris(bipyridine)ruthenium(II) molecules solved in acetonitrile was depleted and the spontaneous Raman scattering at 355 nm suppressed by nearly 50 %. Based on spectroscopic data retrieved from our experiment, we modeled the Raman image of a scattering center in order to demonstrate the applicability of this effect for superresolution Raman microscopy.

4.
Opt Lett ; 39(3): 525-7, 2014 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-24487856

RESUMO

We present an erbium-doped mode-locked fiber laser comprising two all-optical control mechanisms acting on the carrier envelope offset (CEO)-frequency as well as the repetition frequency. The laser's repetition frequency is stabilized via optically pumping a distinct ytterbium-doped fiber module. By proving that additionally controlling the pump power of the erbium-doped gain fiber acts sufficiently complementary on the laser's CEO-frequency compared with repetition frequency stabilization, we demonstrate the feasibility of this concept for an all-optically controlled frequency comb in an all-fiber setup.

5.
Nutrients ; 16(18)2024 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-39339702

RESUMO

BACKGROUND: Despite clinical interventional studies on the influence of diet on periodontal inflammatory parameters, there has been no practice-based cross-sectional study from a German population to date that has conducted both a comprehensive dental and periodontal examination and a thorough validated assessment of dietary behavior. Therefore, the aim of this pilot study was to evaluate, in a proof of concept, whether there is a correlation between the overall periodontal inflammatory surface area (PISA), periodontal clinical parameters (pocket probing depths (PPD), clinical attachment loss (CAL), bleeding on probing (BOP), furcation involvement (FI), tooth mobility (TM)), and the dietary behavior of patients with periodontal disease when utilizing a practice-based research network. The primary outcome was the correlation between the periodontal inflammatory surface (PISA) and the dietary assessment data. MATERIALS AND METHODS: The practice-based research network, consisting of eight Master's graduates, recruited patients who met the inclusion and exclusion criteria and performed a periodontal examination together with the assessment of dietary behavior using a digital version of the validated retrospective dietary recall (DEGS/RKI). Statistical analyses included linear regression models adjusted for age and smoking and unpaired t-tests, conducted using STATA 17.0 with a significance level of 5%. In addition, the data obtained were classified according to the currently recommended amounts of daily intake. RESULTS: A total of 1283 teeth were analyzed, with 60.25% (773 teeth) requiring treatment. The average PISA was 753.16 mm2 (SD ± 535.75 mm). Based on dietary guidelines, the studied population consumed excessive amounts of extrinsic sugars and fats, while their fiber and legume intake was insufficient. The intake of certain nutrients, including water-soluble fibers, specific fatty acids, vitamins (D, B1, B2, B6, and B12), iron, and zinc, was associated with reduced PISA, PPD, CAL, and BOP. CONCLUSION: Within the limits of the current study, including its cross-sectional design and cohort size, the outcomes demonstrated the influence of nutrition on periodontal health.


Assuntos
Periodontite , Humanos , Estudos Transversais , Masculino , Feminino , Pessoa de Meia-Idade , Projetos Piloto , Adulto , Dieta , Estado Nutricional , Alemanha , Comportamento Alimentar , Idoso
6.
Opt Express ; 21(4): 4889-95, 2013 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-23482022

RESUMO

We designed an all-fiber mode-locked Erbium laser with optically stabilized repetition rate of 31.4 MHz. The stabilization was achieved by changing the refractive index of an Ytterbium-doped fiber in the resonator via optical pumping at a wavelength of 978 nm; and for long-term stability the local temperature of the fiber was additionally controlled with a thermo-electric element. The repetition rate was stabilized over 12 hours, and an Allan deviation of 2.5 × 10⁻¹² for an averaging time of 1 s could be achieved.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Lasers , Processamento de Sinais Assistido por Computador/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento
7.
Front Physiol ; 9: 892, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30057553

RESUMO

Retinal vessels show various biological temporal variations that can impact diagnosis using a static vessel analysis. In this study, Mayer waves in the retinal vessel diameter and arterial blood pressure (BP) signals were characterized, and the temporal correlation between these two modalities was investigated. The arterial and venous vessel diameters and arterial BP were recorded simultaneously on human subjects. The obtained vessel diameters showed vasomotion amplitudes over time. The vessel diameter and BP signals contained multiple signals in the frequency domain and varied over time. The signal characteristics were similar within the measurements. The BP and arterial and venous vessel diameters were correlated. The highest correlation values between the signals were observed for shifts of 1 or 0 periods. The spectrum and amplitudes of the Mayer waves showed a high variability. The Mayer waves in the retinal vessel diameters showed the same characteristics as those in the arterial BP. A temporal dependency between the oscillations in the arterial BP and retinal vessel diameters was shown.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA