Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Br J Surg ; 100(8): 1037-44, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23696463

RESUMO

BACKGROUND: Combining radioactive colloids and a near-infrared (NIR) fluorophore permits preoperative planning and intraoperative localization of deeply located sentinel lymph nodes (SLNs) with direct optical guidance by a single lymphatic tracer. The aim of this clinical trial was to evaluate and optimize a hybrid NIR fluorescence and radioactive tracer for SLN detection in patients with breast cancer. METHODS: Patients with breast cancer undergoing SLN biopsy were enrolled. The day before surgery, a periareolar injection of indocyanine green (ICG)-99mTc-radiolabelled nanocolloid was administered and a lymphoscintigram acquired. Blue dye was injected immediately before surgery. Intraoperative SLN localization was performed using a γ probe and the Mini-FLARE™ NIR fluorescence imaging system. Patients were divided into two dose groups, with one group receiving twice the particle density of ICG and nanocolloid, but the same dose of radioactive 99mTc. RESULTS: Thirty-two patients were enrolled in the trial. At least one SLN was identified before and during operation. All 48 axillary SLNs could be detected by γ tracing and NIR fluorescence imaging, but only 42 of them stained blue. NIR fluorescence imaging permitted detection of lymphatic vessels draining to the SLN up to 29 h after injection. Doubling the particle density did not yield a difference in fluorescence intensity (median 255 (range 98-542) versus 284 (90-921) arbitrary units; P = 0.590) or signal-to-background ratio (median 5·4 (range 3·0-15·4) versus 4·9 (3·5-16·3); P = 1·000) of the SLN. CONCLUSION: The hybrid NIR fluorescence and radioactive tracer permitted accurate preoperative and intraoperative detection of the SLNs in patients with breast cancer. REGISTRATION NUMBER: NTR3685 (Netherlands Trial Register; http://www.trialregister.nl).


Assuntos
Neoplasias da Mama/patologia , Mama/patologia , Carcinoma Ductal de Mama/patologia , Carcinoma Lobular/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Lobular/diagnóstico por imagem , Corantes , Feminino , Fluorescência , Humanos , Biópsia Guiada por Imagem , Verde de Indocianina , Cuidados Intraoperatórios/métodos , Metástase Linfática , Linfocintigrafia/métodos , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Biópsia de Linfonodo Sentinela/métodos , Espectroscopia de Luz Próxima ao Infravermelho , Agregado de Albumina Marcado com Tecnécio Tc 99m
2.
Biomater Sci ; 9(5): 1683-1690, 2021 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-33410436

RESUMO

AIM: Pre-targeting is a proven strategy for in vivo delivery of a diagnostic or therapeutic payload. The pre-targeting concept can be realized through various conjugation strategies, one of which is based on copper-free "click" chemistry. Copper-free click reactions have shown in vivo potential for imaging and radionuclide therapy, but this conjugation strategy has not yet been explored in combination with microspheres or unicellular organisms. This study aims to evaluate the in vivo efficacy of strain-promoted azide-alkyne cycloaddition (SPAAC) reactions to achieve imaging and targeting of azide-functionalized macro-aggregated albumin (MAA) microspheres and Staphylococcus aureus bacteria. METHODS: MAA microspheres (diameter 10-90 µm) were functionalized with a biorthogonal Cy5 fluorophore, bearing an azide functionality (N3), to generate MAA-Cy5-N3. S. aureus (diameter ∼1 µm) were functionalized with 99mTc-UBI29-41-Cy5-N3, generating S. aureus-99mTc-UBI29-41-Cy5-N3. In situ and in vitro click conjugation on the -N3 moieties was studied for 20 h using a radioactivity-based assay and fluorescence microscopy. For in vivo validation, both primary entities, radiolabeled with 99mTc, were deposited into the microvasculature of the liver via intrasplenic injections. Secondary targeting was realized following the intravenous administration of indium-111-radiolabeled diethylenetriaminepentaacetic acid-dibenzocyclooctyne (111In-DTPA-DBCO). To assess click reaction efficiency in vivo, 99mTc and 111In-biodistributions were measured (SPECT and %ID g-1). Use of 111In-DTPA-DBCO in mice without MAA deposits or mice infected with non-functionalized S. aureus served as controls. Ex vivo confocal fluorescence imaging was carried out in excised tissues to confirm the presence of functionalized MAA and bacteria. RESULTS: In vitro data confirmed effective click reactions on both the MAA particles and the bacterial membrane. SPECT imaging and biodistribution studies revealed significantly (p < 0.05) increased accumulation of 111In-DTPA-DBCO at the sites where MAA-Cy5-N3 (7.5 ± 1.5%ID g-1vs. 3.5 ± 0.5%ID g-1 in control mice) and S. aureus-99mTc-UBI29-41-Cy5-N3 (9.3 ± 1.3%ID g-1vs. 6.0 ± 0.5%ID g-1 in control mice) resided. Ex vivo fluorescence imaging confirmed the presence of either functionalized MAA or S. aureus in excised spleens and livers of mice. CONCLUSION: Copper-free click chemistry between a DBCO moiety and Cy5-N3-functionalized microspheres or bacterial entities in the liver can be used to realize in vivo imaging and targeting.


Assuntos
Química Click , Medicina Nuclear , Animais , Camundongos , Microesferas , Staphylococcus aureus , Distribuição Tecidual
3.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31133492

RESUMO

PURPOSE: To assess the feasibility of using freehand Single Photon Emission Computed Tomography (freehandSPECT) for the identification of technetium-99m-hydroxydiphosphonate (99mTc-HDP) positive bone lesions and to evaluate the possibility of using these imaging data-sets for augmented- and virtual-reality based navigation approaches. MATERIAL AND METHODS: In 20 consecutive patients referred for scintigraphy with 99mTc-HDP, 21 three-dimensional freehandSPECT-images were generated using a handheld gamma camera. Concordance of the two different data sets was ranked. Furthermore, feasibility of segmenting the hotspot of tracer accumulation for navigation purposes was assessed. RESULTS: In 86% of the cases freehandSPECT images showed good concordance with the corresponding part of the scintigraphic images. In lesions with a signal to background ratio (SBR) >1.36, freehandSPECT provided an automatically segmented reference point for navigation purposes. In 14% of the cases (average SBR 1.82, range 1.0-3.4) freehandSPECT images showed intermediate concordance due to difficult anatomical area or negative bone scintigraphy and could not be used as navigation targets. CONCLUSION: In this pilot study, in 86% of the cases freehandSPECT demonstrated good concordance with traditional scintigraphy. A lesion with a SBR of 1.36 or more was suitable for navigation. These high-quality freehandSPECT images supported the future exploration navigation strategies, e.g. guided needle biopsies.


Assuntos
Biópsia por Agulha/métodos , Doenças Ósseas/diagnóstico por imagem , Câmaras gama , Biópsia Guiada por Imagem/métodos , Medronato de Tecnécio Tc 99m/análogos & derivados , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Doenças Ósseas/patologia , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Método Duplo-Cego , Desenho de Equipamento , Humanos , Biópsia Guiada por Imagem/instrumentação , Especificidade de Órgãos , Imagens de Fantasmas , Projetos Piloto , Compostos Radiofarmacêuticos/farmacocinética , Software , Medronato de Tecnécio Tc 99m/farmacocinética , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Imagem Corporal Total
4.
Rev Esp Med Nucl Imagen Mol ; 35(5): 292-7, 2016.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-27174865

RESUMO

PURPOSE: To assess if combined fluorescence- and radio-guided occult lesion localization (hybrid ROLL) is feasible in patients scheduled for surgical resection of non-palpable (18)F-FDG-avid lesions on PET/CT. METHODS: Four patients with (18)F-FDG-avid lesions on follow-up PET/CT that were not palpable during physical examination but were suspected to harbor metastasis were enrolled. Guided by ultrasound, the hybrid tracer indocyanine green (ICG)-(99m)Tc-nanocolloid was injected centrally in the target lesion. SPECT/CT imaging was used to confirm tracer deposition. Intraoperatively, lesions were localized using a hand-held gamma ray detection probe, a portable gamma camera, and a fluorescence camera. After excision, the gamma camera was used to check the wound bed for residual activity. RESULTS: A total of six (18)F-FDG-avid lymph nodes were identified and scheduled for hybrid ROLL. Comparison of the PET/CT images with the acquired SPECT/CT after hybrid tracer injection confirmed accurate tracer deposition. No side effects were observed. Combined radio- and fluorescence-guidance enabled localization and excision of the target lesion in all patients. Five of the six excised lesions proved tumor-positive at histopathology. CONCLUSION: The hybrid ROLL approach appears to be feasible and can facilitate the intraoperative localization and excision of non-palpable lesions suspected to harbor tumor metastases. In addition to the initial radioguided detection, the fluorescence component of the hybrid tracer enables high-resolution intraoperative visualization of the target lesion. The procedure needs further evaluation in a larger cohort and wider range of malignancies to substantiate these preliminary findings.


Assuntos
Fluordesoxiglucose F18 , Doença de Hodgkin/diagnóstico por imagem , Verde de Indocianina , Melanoma/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos , Agregado de Albumina Marcado com Tecnécio Tc 99m , Adulto , Idoso , Feminino , Doença de Hodgkin/patologia , Humanos , Melanoma/secundário , Imagem Multimodal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA