J Sep Sci ; 35(3): 410-5, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22228597

RESUMO

Active flow management in the form of curtain flow sample introduction and segmented outlet flow control has been shown to enable sample to elute through a chromatography column under the principles of the "infinite diameter column". Such an elution process avoids the detrimental effects of the heterogeneity of particle-packed chromatographic columns by injecting the sample directly into the radial core region of the column, thus avoiding wall effects. The process described herein illustrates how the principles of the infinite diameter column can be applied using conventional injection devices suitable for long-term analysis that requires robust protocols. Using this approach, sensitivity in separation was 2.5 times greater than conventional chromatography, yielding a product at twice the concentration. Benefits of curtain flow injection are thus relevant to both preparative-scale and analytical-scale separations.


Assuntos
Derivados de Benzeno/isolamento & purificação , Análise de Injeção de Fluxo , Tolueno/isolamento & purificação , Cromatografia Líquida/instrumentação , Análise de Injeção de Fluxo/instrumentação
2.
Biomed Chromatogr ; 26(3): 331-7, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21732398

RESUMO

An ultra high-performance liquid chromatographic (UHPLC) system was developed and optimized for the separation of porphyrins of clinical interest. Optimum conditions for the simultaneous separation of uroporphyrin, hepta-, hexa-, penta-carboxylic acid porphyrins and coproporphyrin and their type I and III isomers on a Thermo Hypersil BDS C18 column (2.4 µm particle size, 100 × 2.1 mm i.d.) using a gradient elution with 10% (v/v) acetonitrile in 1.0 m ammonium acetate buffer (pH 5.16) and 10% (v/v) acetonitrile in methanol at a flow-rate of 0.4 mL/min. The effect of mobile phase buffer molarity on the sensitivity of fluorescence detection and resolution of porphyrin isomers was investigated. The method was successfully applied to the analysis of porphyrins extracted from the urine and faeces of patients with various human porphyrias.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Porfirinas/análise , Fezes , Humanos , Porfirias/metabolismo , Porfirias/urina , Extração em Fase Sólida , Espectrometria de Fluorescência
3.
Analyst ; 136(24): 5127-30, 2011 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-22005770

RESUMO

Active Flow Management is a new separation technique whereby the flow of mobile phase and the injection of sample are introduced to the column in a manner that allows migration according to the principles of the infinite diameter column. A segmented flow outlet fitting allows for the separation of solvent or solute that elutes along the central radial section of the column from that of the sample or solvent that elutes along the wall region of the column. Separation efficiency on the analytical scale is increased by 25% with an increase in sensitivity by as much as 52% compared to conventional separations.

4.
J Chromatogr A ; 1232: 47-51, 2012 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-21962497

RESUMO

A new column technology - termed parallel segmented outlet flow was employed here to illustrate gains in separation performance that are achievable by the active management of flow as it exits from the outlet of the chromatography column. Parallel segmented outlet flow requires a column be fitted with an outlet fitting that separates flow from the central region of the column from that of wall region. Each region of flow is able to be processed independently, such that post column detection emulates end column localised detection. As a result of this flow segmentation and the subsequent more efficient means of detection, column efficiency was observed to increase by more than 20%, with gains in sensitivity by as much as 22%, and a decrease in peak volume by up to 85%.


Assuntos
Cromatografia Líquida de Alta Pressão/instrumentação , Cromatografia Líquida de Alta Pressão/métodos , Derivados de Benzeno/isolamento & purificação , Desenho de Equipamento , Modelos Teóricos , Sensibilidade e Especificidade