RESUMO
BACKGROUND: Carmat bioprosthetic total artificial heart (Aeson; A-TAH) is a pulsatile and autoregulated device. The aim of this study is to evaluate level of hemolysis potential acquired von Willebrand syndrome after A-TAH implantation. METHODS: We examined the presence of hemolysis and acquired von Willebrand syndrome in adult patients receiving A-TAH support (n=10) during their whole clinical follow-up in comparison with control subjects and adult patients receiving Heartmate II or Heartmate III support. We also performed a fluid structure interaction model coupled with computational fluid dynamics simulation to evaluate the A-TAH resulting shear stress and its distribution in the blood volume. RESULTS: The cumulative duration of A-TAH support was 2087 days. A-TAH implantation did not affect plasma free hemoglobin over time, and there was no association between plasma free hemoglobin and cardiac output or beat rate. For VWF (von Willebrand factor) evaluation, A-TAH implantation did not modify multimers profile of VWF in contrast to Heartmate II and Heartmate III. Furthermore, fluid structure interaction coupled with computational fluid dynamics showed a gradually increase of blood damage according to increase of cardiac output (P<0.01), however, the blood volume fraction that endured significant shear stresses was always inferior to 0.03% of the volume for both ventricles in all regimens tested. An inverse association between cardiac output, beat rate, and high-molecular weight multimers ratio was found. CONCLUSIONS: We demonstrated that A-TAH does not cause hemolysis or AWVS. However, relationship between HMWM and cardiac output depending flow confirms relevance of VWF as a biological sensor of blood flow, even in normal range.
Assuntos
Coração Artificial , Doenças de von Willebrand , Adulto , Coração Artificial/efeitos adversos , Hemoglobinas , Hemólise , Humanos , Fator de von WillebrandRESUMO
BACKGROUND: Coronavirus disease 2019 (COVID-19) is a respiratory disease associated with endotheliitis and microthrombosis. OBJECTIVES: To correlate endothelial dysfunction to in-hospital mortality in a bi-centric cohort of COVID-19 adult patients. METHODS: Consecutive ambulatory and hospitalized patients with laboratory-confirmed COVID-19 were enrolled. A panel of endothelial biomarkers and von Willebrand factor (VWF) multimers were measured in each patient ≤ 48 h following admission. RESULTS: Study enrolled 208 COVID-19 patients of whom 23 were mild outpatients and 189 patients hospitalized after admission. Most of endothelial biomarkers tested were found increased in the 89 critical patients transferred to intensive care unit. However, only von Willebrand factor antigen (VWF:Ag) scaled according to clinical severity, with levels significantly higher in critical patients (median 507%, IQR 428-596) compared to non-critical patients (288%, 230-350, p < 0.0001) or COVID-19 outpatients (144%, 133-198, p = 0.007). Moreover, VWF high molecular weight multimers (HMWM) were significantly higher in critical patients (median ratio 1.18, IQR 0.86-1.09) compared to non-critical patients (0.96, 1.04-1.39, p < 0.001). Among all endothelial biomarkers measured, ROC curve analysis identified a VWF:Ag cut-off of 423% as the best predictor for in-hospital mortality. The accuracy of VWF:Ag was further confirmed in a Kaplan-Meier estimator analysis and a Cox proportional Hazard model adjusted on age, BMI, C-reactive protein and D-dimer levels. CONCLUSION: VWF:Ag is a relevant predictive factor for in-hospital mortality in COVID-19 patients. More than a biomarker, we hypothesize that VWF, including excess of HMWM forms, drives microthrombosis in COVID-19.
Assuntos
COVID-19/sangue , COVID-19/mortalidade , Pandemias , SARS-CoV-2 , Fator de von Willebrand/metabolismo , Adulto , Idoso , Biomarcadores/sangue , Biomarcadores/química , COVID-19/fisiopatologia , Estudos Transversais , Endotélio Vascular/fisiopatologia , Feminino , Mortalidade Hospitalar , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Peso Molecular , Paris/epidemiologia , Modelos de Riscos Proporcionais , Multimerização Proteica , Índice de Gravidade de Doença , Trombose/sangue , Trombose/etiologia , Fator de von Willebrand/químicaRESUMO
The assessment of von Willebrand factor (VWF) multimer distribution, particularly following the implantation of circulatory support devices, is a crucial parameter in hemostasis. Our study aimed to evaluate the semi-automated quantification of VWF multimers using the Sebia Hydrasys analyzer. Our analysis focused on quantifying high molecular weight, intermediate weight, and low molecular weight VWF multimers. Electrophoretic migration was performed using the Hydrasys 2 scan, and interpretation was carried out using densitometric analysis with the Phoresis software. The Hydrasys scan 2 successfully separated all the expected VWF multimer profiles based on the type of von Willebrand disease. The analysis revealed that in patients with circulatory support devices, elevated levels of plasma VWF rendered multimer migration unanalyzable using the methodology recommended by the manufacturer. Therefore, adjustment to a 100 % VWF antigenic level improved gel precision. We also suggest using as a standardized control the Cryocheck™ plasma, and have established reference values. Overall, this semi-automated, standardized, and optimized VWF multimer analysis system allows for an effective assessment of the VWF multimeric profile.
Assuntos
Doenças de von Willebrand , Fator de von Willebrand , Humanos , Fator de von Willebrand/análise , Doenças de von Willebrand/diagnóstico , Doenças de von Willebrand/sangue , Multimerização Proteica , Automação Laboratorial/normas , Automação Laboratorial/métodos , Automação Laboratorial/instrumentaçãoRESUMO
BACKGROUND: Bone marrow aspiration (BMA) is a medical procedure necessary to the diagnosis and monitoring of patients with hematological or nonhematological disorders. This procedure is considered painful, and patients are generally anxious before and during BMA. OBJECTIVE: This study assesses the effect of immersive virtual reality on pain during BMA. METHODS: This observational prospective and monocentric study enrolled 105 consecutive patients who underwent sternal BMA with lidocaine anesthesia. The study was carried on during 2 periods. First, virtual reality facemask (VRF) was proposed to all patients in the absence of exclusion criteria. During the second period, BMA was performed without the VRF. For all patients, pain intensity after the procedure was assessed using a 10-point numerical pain rating scale (NPRS). All analyses were performed on propensity score-matched cohort (with or without VRF) to evaluate efficacy on NRPS levels. RESULTS: The final matched cohort included 12 patients in the VRF group and 24 in the control group. No difference in anxiety level before BMA evaluated by the patient and by the operator was observed between groups (P=.71 and .42 respectively). No difference of NPRS was observed using VRF when compared to control group (median NPRS 3.8, IQR 2.0-6.3 vs 3.0, IQR 1.9-3.0, respectively; P=.09). CONCLUSIONS: Our study did not prove the efficacy of VRF to reduce pain during BMA.
RESUMO
BACKGROUND: Coronavirus disease-2019 (COVID-19) has been associated with cardiovascular complications and coagulation disorders. OBJECTIVES: To explore the coagulopathy and endothelial dysfunction in COVID-19 patients. METHODS: The study analyzed clinical and biological profiles of patients with suspected COVID-19 infection at admission, including hemostasis tests and quantification of circulating endothelial cells (CECs). RESULTS: Among 96 consecutive COVID-19-suspected patients fulfilling criteria for hospitalization, 66 were tested positive for SARS-CoV-2. COVID-19-positive patients were more likely to present with fever (P = .02), cough (P = .03), and pneumonia at computed tomography (CT) scan (P = .002) at admission. Prevalence of D-dimer >500 ng/mL was higher in COVID-19-positive patients (74.2% versus 43.3%; P = .007). No sign of disseminated intravascular coagulation were identified. Adding D-dimers >500 ng/mL to gender and pneumonia at CT scan in receiver operating characteristic curve analysis significantly increased area under the curve for COVID-19 diagnosis. COVID-19-positive patients had significantly more CECs at admission (P = .008) than COVID-19-negative ones. COVID-19-positive patients treated with curative anticoagulant prior to admission had fewer CECs (P = .02) than those without. Interestingly, patients treated with curative anticoagulation and angiotensin-converting-enzyme inhibitors or angiotensin receptor blockers had even fewer CECs (P = .007). CONCLUSION: Curative anticoagulation could prevent COVID-19-associated coagulopathy and endothelial lesion.
Assuntos
Anticoagulantes/uso terapêutico , COVID-19/complicações , COVID-19/terapia , Idoso , Antagonistas de Receptores de Angiotensina/uso terapêutico , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Coagulação Sanguínea , Transtornos da Coagulação Sanguínea/complicações , Transtornos da Coagulação Sanguínea/tratamento farmacológico , Doenças Cardiovasculares/complicações , Células Endoteliais/metabolismo , Feminino , Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Hemostasia , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Admissão do Paciente , Pneumonia Viral/diagnóstico por imagem , Prevalência , Estudos Prospectivos , Curva ROC , Tomografia Computadorizada por Raios XRESUMO
Although bone marrow aspiration (BMA) is still considered a painful procedure, pain level remains poorly documented. We therefore conducted a prospective study intended to evaluate pain level in adult patients undergoing BMA at the sternal or iliac crest site to identify factors associated with pain. We enrolled a total of 448 patients who underwent 461 BMA and asked those patients to score their pain intensity after BMA using numerical pain rating scale (NPRS). The following factors: level of anxiety, quality of the information given to the patient, operator's experience, and bone texture were recorded using a standardized questionnaire. The median NPRS score was 3.5 (IQR [2.0; 5.0]) the sternal site (n = 405) was associated with an increased median NPRS score (3.5 [2.0; 5.0]) compared to the iliac crest (n = 56, 2.5 [1.0; 4.0]; p<0.0001). For those patients who underwent sternal BMA, the median NPRS score was significantly lower when using lidocaine infiltration (p = 0.0159) as compared with no anesthetic use. Additionally there was no significant effect of anesthetic cream found. After multivariate analysis, the model of NPRS score at the sternal site included patient anxiety (p<0.0001) and the use of lidocaine infiltration (0.0378). This study underlines the usefulness of a comprehensive management including pain relief and efforts to reduce anxiety including appropriate information given to the patient during BMA.
Assuntos
Medula Óssea , Medição da Dor , Dor/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha , Medula Óssea/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dor/etiologia , Dor/fisiopatologia , Medição da Dor/métodosRESUMO
OBJECTIVE: To identify common temporal evolution profiles in biological data and propose a semi-automated method to these patterns in a clinical data warehouse (CDW). MATERIALS AND METHODS: We leveraged the CDW of the European Hospital Georges Pompidou and tracked the evolution of 192 biological parameters over a period of 17 years (for 445,000â¯+â¯patients, and 131 million laboratory test results). RESULTS: We identified three common profiles of evolution: discretization, breakpoints, and trends. We developed computational and statistical methods to identify these profiles in the CDW. Overall, of the 192 observed biological parameters (87,814,136 values), 135 presented at least one evolution. We identified breakpoints in 30 distinct parameters, discretizations in 32, and trends in 79. DISCUSSION AND CONCLUSION: our method allowed the identification of several temporal events in the data. Considering the distribution over time of these events, we identified probable causes for the observed profiles: instruments or software upgrades and changes in computation formulas. We evaluated the potential impact for data reuse. Finally, we formulated recommendations to enable safe use and sharing of biological data collection to limit the impact of data evolution in retrospective and federated studies (e.g. the annotation of laboratory parameters presenting breakpoints or trends).
Assuntos
Serviços de Laboratório Clínico/estatística & dados numéricos , Confiabilidade dos Dados , Data Warehousing/métodos , Registros Eletrônicos de Saúde/estatística & dados numéricos , Armazenamento e Recuperação da Informação , Informática Médica/métodos , Automação , Sistemas de Gerenciamento de Base de Dados , França/epidemiologia , Humanos , Reconhecimento Automatizado de Padrão , Reprodutibilidade dos Testes , Estudos Retrospectivos , Software , Integração de Sistemas , Fatores de TempoRESUMO
We report the case of a 20 years old man presenting two episodes of hematemesis. The patient was known to suffer from depression and was treated with sertraline (Zoloft®) for 6 months at the dosage of 100 mg/day. No endoscopic and radiological abnormality was found. The haemostasis report was normal. Exploration of platelet function was in favor of an abnormality of platelet secretion as evidenced by low epinephrine-induced aggregation, a slightly reduced aggregation for following agonists: TRAP, ADP 5 µM and 10 µM, and a longer latency to collagen. The diagnosis of an acquired platelet disorder was strongly suspected and in particular an acquired platelet disorder induced by selective serotonin reuptake inhibitors that is known to interfere with platelet activation pathways involving serotonin.