Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
BMC Musculoskelet Disord ; 22(1): 768, 2021 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-34496807

RESUMO

BACKGROUND: Locked posterior glenohumeral dislocations with a reverse Hill-Sachs impaction fracture involving less than 30% of the humeral head are most frequently treated with lesser tuberosity transfer into the defect, whereas those involving more than 50% undergo humeral head arthroplasty. Reconstruction of the defect with segmental femoral osteochondral allografts has been proposed to treat patients between these two ranges, but the medium-/long-term outcomes of this joint-preserving procedure are controversial. METHODS: Between 2001 and 2018, 12 consecutive patients with a unilateral locked posterior shoulder dislocation and an impaction fracture from 30 to 50% (mean 31% ± 1.32) of the humeral head were treated with segmental reconstruction of the defect with fresh-frozen humeral head osteochondral allografts. Patients were assessed clinically, radiographically and with computed tomography (CT) at a medium follow-up of 66 ± 50.25 months (range, 24-225). RESULTS: All twelve shoulders presented a slight limitation in anterior elevation (average, 166.6° ± 22.76). The mean active external rotation with the shoulder at 90° of abduction was 82.5° ± 6.61, and that with the arm held in stable adduction was 79.16 ± 18.80. The mean abduction was 156.25° ± 25.09. The mean Constant-Murley score (CS) was 82 ± 15.09 points (range, 40-97 points), and the mean ASES was 94 ± 8.49 points. The mean pre- and postoperatively Western Ontario Shoulder Instability index (WOSI) was 236.5 ± 227.9 and 11.20 ± 10.85, respectively. Development of osteoarthrosis (OA) was minimal. The average allograft resorption rate was 4% ± 2.4. There were no cases of failure (reoperation for any reason) in this series. CONCLUSION: Segmental humeral head reconstruction with humeral head fresh-frozen osteochondral allografts provides good to excellent clinical results with low-grade OA and low allograft resorption in patients with locked posterior shoulder dislocation. TRIAL REGISTRATION: ClinicalTrials.gov PRS, ClinicalTrials.gov ID: NCT04823455 . Registered 29 March 2021 - Retrospectively registered, https://register.clinicaltrials.gov/prs/app/action/SelectProtocol?sid=S000AU8P&selectaction=Edit&uid=U0004J36&ts=12&cx=6cykp8 LEVEL OF EVIDENCE: Level IV, Case Series, Treatment Study.


Assuntos
Lesões de Bankart , Instabilidade Articular , Articulação do Ombro , Aloenxertos , Humanos , Cabeça do Úmero/diagnóstico por imagem , Cabeça do Úmero/cirurgia , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia
2.
Knee Surg Sports Traumatol Arthrosc ; 27(8): 2698-2703, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30474693

RESUMO

PURPOSE: To assess the relationship between the KiRA triaxial accelerometer and the KT-1000 measurements in the intact, anterior cruciate ligament (ACL) deficient, and ACL reconstructed knee joint for the quantification of the Lachman test. Moreover, the intra- and inter-examiner repeatability of the KiRA device will be determined. It was hypothesized that the side-to-side difference of the anterior tibial translation as measured by the KiRA device would be equivalent to the one measured by the KT-1000 during the Lachman test. METHODS: Sixty patients were divided into three groups and have been prospectively included in the present study. Group_A composed of 20 patients with a diagnosis of an isolated ACL tear. Group_B composed of 20 patients who underwent ACL reconstruction with a Single-Bundle Lateral Plasty (SBLP) technique with at least 20 years of follow-up. Group_C was the control group and included 20 patients with no history of ACL lesion. Lachman test has been performed at manual-maximum load on both sides, the involved and the contralateral and analyzed with the two different devices. RESULTS: The KiRA device in terms of side-to-side difference resulted not statistically different from the measurement of the KT-1000 arthrometer for the three study groups (n.s): Group_A: (4 ± 2 mm KiRA, 4 ± 2 mm KT1000), Group_B: (4 ± 2 mm KiRA, 4 ± 2 mm KT-1000), Group_C: (4 ± 2 mm KiRA, 4 ± 2 mm KT-1000), an excellent intra- (ICC = 0.88-0.89) and inter-examiner (ICC = 0.79) agreement was found for KiRA measurements. CONCLUSION: The KiRA (I+, Italy) device offers a valid method to quantify the Lacham test. LEVEL OF EVIDENCE: II.


Assuntos
Acelerometria/instrumentação , Instabilidade Articular/diagnóstico , Articulação do Joelho/fisiopatologia , Adulto , Ligamento Cruzado Anterior/fisiopatologia , Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/fisiopatologia , Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior , Feminino , Humanos , Instabilidade Articular/cirurgia , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Exame Físico/métodos , Tíbia/cirurgia , Adulto Jovem
3.
Int Orthop ; 43(5): 1071-1082, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30032356

RESUMO

PURPOSE: Although long-term reports of total hip arthroplasty (THA) showed successful results, instability remains a major complication. Recently, dual-mobility cups (DMC) have gained more and more interest among clinicians, with encouraging results in terms of lower rate of dislocation associated with good clinical results, but a lack of evidence exists regarding the real efficacy of this implant design compared to traditional fixed-bearing total hip arthroplasties. METHODS: A systematic search was performed in PubMed, Google scholar, Cochrane Library, and EMBASE by two independent reviewers for comparative studies available till December 2017, with the primary objective to demonstrate a real lower dislocation rate of DMC implants compared to unipolar fixed-bearing cup designs. A meta-analysis was conducted with the collected pooled data about dislocation rate, calculating the risk difference (RD) and relative risk (RR) with 95% CI for dichotomous variables. Heterogeneity was tested using the χ2 and Higgins' I2 tests. A fixed-effect model was used because the statistical heterogeneity was below 50%. RESULTS: After performing a critical exclusion process, the number of eligible studies included for final synthesis considered was 15, describing the results of a total of 2408 total hip arthroplasties (50.6% with a dual-mobility acetabular cup design, 49.4% with a standard fixed-bearing design). The fixed-effect meta-analysis showed a slight significant risk ratio of 0.16 (95% CI, 0.09, 0.28; I2 = 0%, p < 0.00001); a statistically significant difference in favor of the DMC group was maintained also considering only primary or revision arthroplasties, traumatic fractures or elective patients with diagnosis of osteoarthritis, avascular osteonecrosis or rheumatic arthritis. CONCLUSIONS: With the intrinsic limitations of our study design and based on the current available data, this study demonstrates that dual-mobility acetabular components decrease the risk of post-operative instability also in high-risk patients, both in primary and revision hip arthroplasties. However, new high-quality studies, possibly with a randomized control design, should be undertaken in order to strengthen the present data. STUDY DESIGN: Level of Evidence III, therapeutic study.


Assuntos
Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Luxação do Quadril/prevenção & controle , Instabilidade Articular/prevenção & controle , Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Procedimentos Cirúrgicos Eletivos/efeitos adversos , Luxação do Quadril/etiologia , Prótese de Quadril/efeitos adversos , Humanos , Instabilidade Articular/etiologia , Desenho de Prótese , Falha de Prótese , Amplitude de Movimento Articular
4.
Knee Surg Sports Traumatol Arthrosc ; 26(8): 2410-2423, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29423546

RESUMO

PURPOSE: To determine how the incision technique for hamstring tendon (HT) harvest in anterior cruciate ligament (ACL) reconstruction affects the risk of injury to the IPBSN and clinical outcome. METHODS: A systematic literature search of the MEDLINE/Pubmed, Cochrane Central Register of Controlled Trials (CENTRAL) and EBSCOhost electronic databases and clinicaltrials.gov for unpublished studies was performed to identify comparative studies investigating injury to the IPBSN after HT ACL reconstruction by comparing at least two different incision techniques. Data were extracted for the number of patients with evidence of any neurologic deficit corresponding to injury to the IPBSN, area of sensory deficit, the Lysholm score and patient satisfaction. The mean difference (MD) in study outcome between incision groups was assessed. The relative risk (RR) and the number needed to treat (NNT) were calculated. The Chi-square and Higgins' I2 tests were applied to test heterogeneity. Data were pooled using a Mantel-Haenszel random-effects model if the statistical heterogeneity was > 50% and a fixed-effects model if the statistical heterogeneity was < 50%. The risk of bias was evaluated according to the Cochrane Database questionnaire and the quality of evidence was graded according to the Grading of Recommendations Assessment, Development and Evaluation (GRADE) guidelines. RESULTS: A total of eight studies (three randomized controlled trials (RCTs) and five comparative studies) were included, of which six compared vertical and oblique incisions, one horizontal and vertical incisions, and one compared all three techniques. HT harvest was performed through a vertical incision in 329 patients, through an oblique incision in 195 patients and through a horizontal incision in 151 patients. Considering the meta-analysis of the RCTs, the performance of a vertical incision significantly increased the risk of causing IPBSN deficiency compared with both oblique and horizontal incision [RR 1.65 (CI 1.10-2.49, p = 0.02) and RR 2.45 (CI 1.73-3.47, p < 0.0001), respectively]. A significantly larger area of sensory deficit was found with vertical incisions compared with oblique ones, with an MD of 22.91 cm2 (95% CI 7.73-38.08; p = 0.04). No significant differences were found between the incision techniques in relation to patient-reported outcomes. The same trend was obtained after the performing a meta-analysis of all eight included studies. The quality of evidence in this meta-analysis was determined as "low" to "moderate", mostly due to inadequate methods of randomization and high heterogeneity among the included studies. CONCLUSION: The performance of a vertical incision to harvest HTs for ACL reconstruction significantly increased the risk of iatrogenic injury to the IPBSN compared with both oblique and horizontal incisions. LEVEL OF EVIDENCE: Level I-III, meta-analysis of comparative studies.


Assuntos
Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Tendões dos Músculos Isquiotibiais/transplante , Patela/inervação , Traumatismos dos Nervos Periféricos/etiologia , Coleta de Tecidos e Órgãos/efeitos adversos , Humanos , Complicações Pós-Operatórias , Fatores de Risco
5.
New Microbiol ; 40(2): 130-134, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28255603

RESUMO

The aim of this prospective study was to evaluate the performance of the Polymerase Chain Reaction (PCR) tool Xpert MRSA/SA SSTI test (Cepheid, Sunnyvale, CA, USA) on periprosthetic samples from a cohort of patients with suspected prosthetic joint infection (PJI). Seventy adult patients were included in this prospective study. On the basis of the preoperative evaluation, 39 patients were clinically considered to have a PJI, whereas 31 were presumed to suffer from an aseptic mobilization of the implant. Xpert MRSA/SA SSTI identified 4 out of 4 MRSA, 7 out of 7 MSSA, and 14 out of 16 methicillin resistant CoNS. Among the 31 patients not having a PJI, the rapid PCR did not find any bacteria among those identifiable, thus demonstrating an excellent performance in terms of specificity. Statistical analysis of the analytical performance showed a high correlation (p<0.001) between the result of Xpert MRSA/SA SSTI and culture. Xpert MRSA/SA SSTI assay is a novel, yet well known, rapid and accurate method for the identification of different species of staphylococci. The test can be used with peri-operative samples thus dramatically improving the diagnostic sensitivity. In addition, thanks to the very short turnaround time the use of Xpert assay can modify the clinical management of patients suffering from PJI during the ongoing operative procedure.


Assuntos
Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/microbiologia , Staphylococcus/isolamento & purificação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Coagulase/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase em Tempo Real/métodos , Sensibilidade e Especificidade , Adulto Jovem
6.
J Foot Ankle Surg ; 56(4): 776-782, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28633776

RESUMO

Arthroereisis of the subtalar joint is a common surgical technique in Europe for the management of flexible flatfoot in the pediatric population. In most cases, it is performed using a calcaneo-stop metallic screw. Despite the good clinical results, screw removal is always advised after 2 to 3 years. The use of a bioabsorbable screw might overcome the need for a second operation to remove a nonabsorbable device. We report the results of a biodegradable calcaneo-stop screw at a minimum of 4 years of follow-up. Eighty-eight procedures were performed on 44 children. All patients were clinically and radiologically evaluated preoperatively and at a minimum 4-year follow-up period. Patient satisfaction and plantar collapse using Viladot's classification were recorded. Meary's talus-first metatarsal angle and talocalcaneal angle were measured on radiographs preoperatively and at the last follow-up visit. The presence of the device at the last follow-up examination was assessed by magnetic resonance imaging. The mean follow-up duration was 56 months. Of the 44 patients, 33 (75%) reported excellent clinical outcomes, 9 (20.5%) good outcomes, and 2 (4.5%) poor. Foot print improvement was registered for all patients. The mean Meary's talus-first metatarsal angle had improved from 160.6° ± 7.7° preoperatively to 170.6° ± 6.5° at the last follow-up visit (p < .001). The talocalcaneal angle had decreased from 39.9° ± 5.2° preoperatively to 29.4° ± 4° at the last follow-up examination (p < .001). At the 4-year follow-up point, the implant could be seen to have almost completely biodegraded on magnetic resonance imaging. Two screw breakages occurred. The bioabsorbable calcaneo-stop screw seems to be an effective solution for flexible flatfoot in pediatric patients. Also, owing to its biodegradable composition, the need of a second operation for implant removal will not always be necessary.


Assuntos
Implantes Absorvíveis , Artrodese/instrumentação , Parafusos Ósseos , Pé Chato/cirurgia , Adolescente , Criança , Feminino , Pé Chato/diagnóstico por imagem , Seguimentos , Humanos , Imageamento por Ressonância Magnética , Masculino , Satisfação do Paciente , Estudos Retrospectivos , Resultado do Tratamento
7.
Foot Ankle Surg ; 23(2): 116-121, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28578794

RESUMO

BACKGROUND: A new design of 3-part ankle replacement was developed to achieve compatibility with the natural ligaments by allowing certain fibers to remain isometric during passive motion. METHODS: We evaluate 75 ankle prostheses implanted from July 2003 to December 2008, at a mean follow-up 6.5±1.1years (range 5-9 years). The mean age at surgery was 62±13years (range 29-82). RESULTS: The mean AOFAS scores achieved at pre-op and at last follow-up were respectively 37±5 (23-45) and 78±8 (64-98). (p<0.001). Clinical range of motion of the ankle measured by goniometer pre op was 1°±2 of dorsiflexion and 12°±4° of plantarflexion; at last follow-up range of motion increased to 6°±5° in dorsiflexion (p<0.01) and 18°±7° in plantarflexion (p<0.05). Radiographs showed no loosening and little signs of radiolucency. Two revisions necessitated component removal, neither for implant loosening. The overall survival rate was 97.3%. CONCLUSIONS: Function and Range-of-motion showed significant improvements. These results demonstrate that ligaments-compatible shaped talar and tibial components, with a fully conforming interposed meniscal bearing, can provide satisfactory survival rates and clinical outcomes in the middle term.


Assuntos
Artrite Reumatoide/cirurgia , Artroplastia de Substituição do Tornozelo/instrumentação , Prótese Articular , Ligamentos , Osteoartrite/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Amplitude de Movimento Articular , Fatores de Tempo , Resultado do Tratamento
8.
Eur J Orthop Surg Traumatol ; 27(7): 967-981, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28124130

RESUMO

BACKGROUND: Soccer is considered the most popular sport in the world concerning both audience and athlete participation, and the incidence of ACL injury in this sport is high. The understanding of injury situations and mechanisms could be useful as substratum for preventive actions. PURPOSE: To conduct a video analysis evaluating the situations and mechanisms of ACL injury in a homogeneous population of professional male soccer players, through a search entirely performed on the YouTube.com Web site focusing on the most recent years. METHODS: A video analysis was conducted obtaining videos of ACL injury in professional male soccer players from the Web site YouTube. Details regarding injured players, events and situations were obtained. The mechanism of injury was defined on the basis of the action, duel type, contact or non-contact injury, and on the hip, knee and foot position. RESULTS: Thirty-four videos were analyzed, mostly from the 2014-2015 season. Injuries occurred mostly in the first 9 min of the match (26%), in the penalty area (32%) or near the side-lines (44%), and in non-rainy conditions (97%). Non-contact injuries occurred in 44% of cases, while indirect injuries occurred in 65%, mostly during pressing, dribbling or tackling. The most recurrent mechanism was with an abducted and flexed hip, with knee at first degrees of flexion and under valgus stress. CONCLUSIONS: Through a YouTube-based video analysis, it was possible to delineate recurrent temporal, spatial and mechanical characteristics of ACL injury in male professional soccer players. LEVEL OF EVIDENCE: Level IV, case series.


Assuntos
Lesões do Ligamento Cruzado Anterior/etiologia , Futebol/lesões , Humanos , Masculino , Equilíbrio Postural/fisiologia , Gravação em Vídeo
9.
J Exp Orthop ; 11(1): e12001, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38464507

RESUMO

Purpose: Various surgical treatments have been described for the treatment of reverse Hill-Sachs lesions (rHSls) sized between 20% and 50% in the case of posterior shoulder dislocation. The aim of this systematic review is to report the clinical and radiological outcomes of subscapularis or lesser tuberosity transfer (McLaughlin and modified procedures) compared to bone or osteochondral autograft or allograft. Methods: A systematic review was performed on five medical databases up to December 2022. The inclusion criteria were clinical studies of all levels of evidence describing clinical or radiological outcomes of either procedure. The assessment of the quality of evidence was performed with the Modified Coleman Score. Results: A total of 14 studies (five prospective and nine retrospective) were included. A total of 153 patients (155 shoulders, 78.4% male) with a mean age of 37.2 (22-79) years were reviewed at an average follow-up of 53.1 (7.1-294) months. No relevant difference was found for the clinical scores, range of motion, complications and redislocation rate between the two treatments. Radiological osteoarthritis (OA) was reported in 11% (10/87) in the McLaughlin group and in 21% (16/73) in the humeral reconstruction group. Conclusions: McLaughlin and anatomic humeral reconstruction lead to similar satisfactory clinical results and a low redislocation rate in the treatment of rHSls. Anatomic humeral reconstruction seems associated with an increased risk of OA progression. Level of Evidence: Level IV.

10.
Artigo em Inglês | MEDLINE | ID: mdl-38228809

RESUMO

Chat-GPT, a natural language processing (NLP) tool created by Open-AI, can potentially be used as a quick source for obtaining information related to prostate cancer. This study aims to analyze the quality and appropriateness of Chat-GPT's responses to inquiries related to prostate cancer compared to those of the European Urology Association's (EAU) 2023 prostate cancer guidelines. Overall, 195 questions were prepared according to the recommendations gathered in the prostate cancer section of the EAU 2023 Guideline. All questions were systematically presented to Chat-GPT's August 3 Version, and two expert urologists independently assessed and assigned scores ranging from 1 to 4 to each response (1: completely correct, 2: correct but inadequate, 3: a mix of correct and misleading information, and 4: completely incorrect). Sub-analysis per chapter and per grade of recommendation were performed. Overall, 195 recommendations were evaluated. Overall, 50/195 (26%) were completely correct, 51/195 (26%) correct but inadequate, 47/195 (24%) a mix of correct and misleading and 47/195 (24%) incorrect. When looking at different chapters Open AI was particularly accurate in answering questions on follow-up and QoL. Worst performance was recorded for the diagnosis and treatment chapters with respectively 19% and 30% of the answers completely incorrect. When looking at the strength of recommendation, no differences in terms of accuracy were recorded when comparing weak and strong recommendations (p > 0,05). Chat-GPT has a poor accuracy when answering questions on the PCa EAU guidelines recommendations. Future studies should assess its performance after adequate training.

11.
Urology ; 185: 59-64, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38331221

RESUMO

OBJECTIVE: To identify which medications are mostly associated with ejaculatory disorders through a disproportionality analysis. METHODS: The Food and Drug Administration Adverse Event Reporting System (FDA-FAERS) and the Eudra-Vigilance (EV) database were queried to identify medications more commonly associated to ejaculatory disorders from September 10, 2012 to June 1, 2023. Proportional Reported Ratios (PRRs) were computed for all the selected drugs. RESULTS: Overall, 7404 reports of ejaculatory disorders reports were identified, and of these, 6854 cases (92.6%) were attributed to ten specific medications. On FDA-FAERS and EV databases, Paroxetine and Tamsulosin were the main responsible of delayed ejaculation (103/448 events, 23.0%) and retrograde ejaculation (366/1033 events, 35.4%), respectively. Finasteride was mostly related to painful ejaculation and ejaculation failure, with 150 events (7.8%) and 735 events (38.4%) respectively. Within the group of high-risk medications, Sildenafil presented higher risk of ejaculatory disorders than Tadalafil (PRR=5.85 (95%CI 5.09-6.78), P < .01). CONCLUSION: Ten drugs were recognized to display significant reporting levels of ejaculatory disorders. Among them, Finasteride and Sildenafil were responsible for the most reports in FDA-FAERS and in EV databases, respectively. Physicians should thoroughly counsel patients treated with these drugs about the risk of ejaculatory disorders. Further integration into clinical trials is needed to enhance the applicability and significance of these results.


Assuntos
Finasterida , Farmacovigilância , Masculino , Estados Unidos , Humanos , Finasterida/efeitos adversos , Citrato de Sildenafila , United States Food and Drug Administration , Tansulosina , Bases de Dados Factuais
12.
J Clin Med ; 12(5)2023 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-36902607

RESUMO

The use of tricalcium phosphate (TCP) as a bone substitute is gaining increasing interest to treat severe acetabular bone defects in revision total hip arthroplasty (rTHA). The aim of this study was to investigate the evidence regarding the efficacy of this material. A systematic review of the literature was performed according to the PRISMA and Cochrane guidelines. The study quality was assessed using the modified Coleman Methodology Score (mCMS) for all studies. A total of eight clinical studies (230 patients) were identified: six on TCP used as biphasic ceramics composed of TCP and hydroxyapatite (HA), and two as pure-phase ceramics consisting of TCP. The literature analysis showed eight retrospective case series, of which only two were comparative studies. The mCMS showed an overall poor methodology (mean score 39.5). While the number of studies and their methodology are still limited, the available evidence suggests safety and overall promising results. A total of 11 cases that underwent rTHA with a pure-phase ceramic presented satisfactory clinical and radiological outcomes at initial short-term follow-up. Further studies at long-term follow-up, involving a larger number of patients, are needed before drawing more definitive conclusions on the potential of TCP for the treatment of patients who undergo rTHA.

13.
J Orthop Surg Res ; 18(1): 742, 2023 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-37777776

RESUMO

BACKGROUND: Custom-made implants are a valid option in revision total hip arthroplasty to address massive acetabular bone loss. The aim of this study was to assess the accuracy of custom-made acetabular implants between preoperative planning and postoperative positioning using CT scans. METHODS: In a retrospective analysis, three patients who underwent an acetabular custom-made prosthesis were identified. The custom-made designs were planned through 3D CT analysis considering surgical points of attention. The accuracy of intended implants positioning was assessed by comparing pre- and postoperative CT analyzing the center of rotation (CoR), anteversion, inclination, screws, and implant surface in contact with the bone. RESULTS: The three cases presented satisfactory accuracy in positioning. A malpositioning in the third case was observed due to the posterization of the CoR of the implant of more than 10 mm. The other CoR vectors considered in the third patient and all vectors in the other two cases fall within 10 mm. All the cases were positioned with a difference of less than 10° of anteversion and inclination with respect to the planning. CONCLUSIONS: The current case series revealed promising accuracy in the positioning of custom-made acetabular prosthesis comparing the planned implant in preoperative CT with postoperative CT.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Estudos Retrospectivos , Artroplastia de Quadril/métodos , Reoperação , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Tomografia Computadorizada por Raios X
14.
Int Orthop ; 36(3): 571-8, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21789498

RESUMO

PURPOSE: In some cases of total ankle replacement, perfect alignment of the prosthetic components is not achieved. This study analyses the extent to which component positioning is critical for the final range of motion. METHODS: Fourteen patients undergoing total ankle replacement were assessed preoperatively and postoperatively at seven and 13 months follow-up. X-ray pictures of the ankle were taken in static double leg stance, i.e. at neutral joint position, and in maximum plantarflexion and dorsiflexion. Measurements were obtained by a specially devised computer program based on anatomical reference points digitised on the radiograms. These allowed calculation of the position and orientation of the components in the sagittal and coronal planes, together with the joint range of motion. RESULTS: The mean range of motion was about 34 degrees at the first follow-up and maintained at the second. Tibial and talar components were more anterior than the mid-tibial shaft in 11 and nine patients, respectively. Mean inclination was about four degrees posterior for the tibial component and nearly one degree anterior for the talar component. A significantly larger range of motion was found in ankles both with the talar component located and inclined more anteriorly than the tibial. CONCLUSIONS: Correlation, though weak, was found between motion at the replaced ankle and possible residual subluxation and inclination of the components. However, a satisfactory range of motion was also achieved in those patients where recommended locations for the components could not be reached because of the size of the original joint deformity.


Assuntos
Articulação do Tornozelo/cirurgia , Artroplastia de Substituição do Tornozelo/métodos , Ajuste de Prótese/métodos , Adulto , Idoso , Traumatismos do Tornozelo/cirurgia , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/fisiopatologia , Artrite Reumatoide/cirurgia , Artroplastia de Substituição do Tornozelo/efeitos adversos , Artroplastia de Substituição do Tornozelo/instrumentação , Mau Alinhamento Ósseo/diagnóstico por imagem , Mau Alinhamento Ósseo/etiologia , Feminino , Humanos , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/etiologia , Masculino , Pessoa de Meia-Idade , Osteoartrite/cirurgia , Complicações Pós-Operatórias , Ajuste de Prótese/efeitos adversos , Radiografia , Amplitude de Movimento Articular
15.
Biomed Res Int ; 2022: 3248526, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35813233

RESUMO

Purpose: The purpose of this study is to compare the functional and clinical outcomes, blood loss, complication rate, and hospital length of stay (LOS) of total hip replacement (THR) using a minimally invasive tissue-sparing posterior superior (TSPS) approach and the standard posterior approach. Materials and Methods: This retrospective, observational, double-centered study included 38 patients undergoing hip replacement. The patents were divided into two groups: control group (19 patients), who underwent surgery with the standard posterior approach, and treatment group (19 patients), who received the same type of implant with ceramic-on-ceramic bearing via the TSPS approach. Hemoglobin level was assessed preoperatively, on first and second postoperative days, and on discharge day. Harris hip score and Western Ontario and McMaster Universities Arthritis Index were used to measure the clinical and functional outcomes. Hospital LOS and incidence of early and late complications were assessed in both groups. Postoperative anteroposterior pelvis X-ray was performed to assess the correct positioning of implants. Results: Better early clinical outcomes (p = 0.0155), lesser blood loss (p < 0.0001), and reduced hospital LOS (p < 0.0001) were observed in the TSPS group than in the control group. No major adverse effects occurred in both groups, and a satisfactory implant orientation was achieved in all patients. Conclusions: The TSPS approach is a reliable minimally invasive procedure for THR as it allows an accurate orientation of the components and provides better early postoperative functional outcomes, faster recovery, significantly lower blood loss, and shorter hospital LOS than the standard posterior approach. However, further research is needed to confirm the promising results and cost-effectiveness of the TSPS approach in larger cohorts with a longer follow-up period.


Assuntos
Artroplastia de Quadril , Artroplastia de Quadril/métodos , Humanos , Tempo de Internação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Período Pós-Operatório , Estudos Retrospectivos , Resultado do Tratamento
16.
Front Aging Neurosci ; 14: 806418, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35356302

RESUMO

Spatial cognition is known to decline with aging. However, little is known about whether training can reduce or eliminate age-related deficits in spatial memory. We investigated whether a custom-designed video game involving spatial navigation, obstacle avoidance, and balance control would improve spatial memory in older adults. Specifically, 56 healthy adults aged 65 to 84 years received 10 sessions of multicomponent video game training, based on a virtual cityscape, over 5 weeks. Participants were allocated to one of three training conditions: the main intervention, the "CityQuest" group (n = 19), and two control groups, spatial navigation without obstacle avoidance ("Spatial Navigation-only" group, n = 21) and obstacle avoidance without spatial navigation ("Obstacles-only" group, n = 15). Performance on object recognition, egocentric and allocentric spatial memory (incorporating direction judgment tasks and landmark location tasks, respectively), navigation strategy preference, and executive functioning was assessed in pre- and post-intervention sessions. The results showed an overall benefit on performance in a number of spatial memory measures and executive function for participants who received spatial navigation training, particularly the CityQuest group, who also showed significant improvement on the landmark location task. However, there was no evidence of a shift from egocentric to allocentric strategy preference. We conclude that spatial memory in healthy older participants is amenable to improvement with training over a short term. Moreover, technology based on age-appropriate, multicomponent video games may play a key role in cognitive training in older adults.

17.
J Foot Ankle Surg ; 50(6): 641-7, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21840736

RESUMO

A new design for a 3-part ankle replacement was developed in an effort to achieve compatibility with the naturally occurring ligaments of the ankle by allowing certain fibers to remain isometric during passive motion. In order to test the design concept clinically, 158 prostheses were implanted in 156 patients within a 9-center trial and were followed up for a mean of 17 (range 6 to 48) months. The mean age at the time of surgery was 60.5 (range 29.7 to 82.5) years. Outcome measures included the American Orthopaedic Foot & Ankle Surgery hindfoot-ankle score and range of motion measured on lateral radiographs of the ankle. The preoperative American Orthopaedic Foot & Ankle Surgery score of 36.3 rose to 74.6, 78.6, 76.4, and 79.0, respectively, at 12, 24, 36, and 48 months. A significant correlation between meniscal bearing movement on the tibial component (mean 3.3 mm; range 2 to 11 mm) and range of flexion at the replaced ankle (mean 26.5°; range 14° to 53°) was observed in radiograms at extreme flexions. Two (1.3%) revisions in the second and third postoperative years necessitated component removal (neither were for implant failure), and 7 (4.4%) further secondary operations were required. The results of this investigation demonstrated that non-anatomic-shaped talar and tibial components, with a fully conforming interposed meniscal bearing, can provide safety and efficacy in the short term, although a longer follow-up period is required to more thoroughly evaluate this ankle implant.


Assuntos
Articulação do Tornozelo/cirurgia , Artroplastia de Substituição do Tornozelo/métodos , Desenho de Prótese , Amplitude de Movimento Articular/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Articulação do Tornozelo/fisiopatologia , Artroplastia de Substituição do Tornozelo/efeitos adversos , Estudos de Coortes , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Prótese Articular , Masculino , Pessoa de Meia-Idade , Osteoartrite/diagnóstico , Osteoartrite/cirurgia , Medição da Dor , Cuidados Pós-Operatórios/métodos , Falha de Prótese , Recuperação de Função Fisiológica , Reoperação/estatística & dados numéricos , Medição de Risco , Fatores de Tempo , Resultado do Tratamento
18.
Clin Orthop Relat Res ; 468(10): 2746-53, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20559763

RESUMO

BACKGROUND: A three-part ankle replacement was developed to achieve compatibility with the natural ligaments by allowing fibers on the medial and lateral sides to remain isometric during passive motion. Unlike all current prostheses, the new design uses nonanatomically shaped components on the tibia and talus and a fully conforming interposed meniscal bearing. QUESTIONS/PURPOSES: Does this new design restore ankle mobility, improve clinical score, and result in low complication and early revision rates? PATIENTS AND METHODS: We reviewed 51 patients in whom 51 prostheses were implanted in a seven-center trial from July 2003 to July 2006. The mean age of the patients at surgery was 61.5 years (range, 35.1-82.5 years). We used the AOFAS score to assess clinical outcome. We used lateral radiographs to assess function. The minimum followup was 24 months (mean, 30 months; range, 24-48 months). RESULTS: The mean preoperative AOFAS score of 38.5 increased to 76.9, 79.1, 76.4, and 79.0 at 12, 24, 36, and 48 months, respectively. We observed a correlation between meniscal bearing movement on the tibial component (mean, 3.4 mm; range, 2-12 mm) and range of flexion at the replaced ankle (mean, 27.4º; range, 16º-53º). We revised one arthroplasty in the second postoperative year for lateral impingement, providing a 3-year cumulative survival rate of 97% and performed one other secondary operation for hindfoot pain. CONCLUSIONS: These data suggest the new prosthesis can provide short-term restoration of ankle mobility, a good clinical score, and low complication and failure rates. Longer followup with larger numbers is required. LEVEL OF EVIDENCE: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.


Assuntos
Articulação do Tornozelo/cirurgia , Artroplastia de Substituição/métodos , Ligamentos Laterais do Tornozelo/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/fisiopatologia , Artroplastia de Substituição/efeitos adversos , Artroplastia de Substituição/instrumentação , Feminino , Humanos , Itália , Prótese Articular , Ligamentos Laterais do Tornozelo/diagnóstico por imagem , Ligamentos Laterais do Tornozelo/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Radiografia , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Reoperação , Fatores de Tempo , Resultado do Tratamento , Suporte de Carga
19.
Eur J Radiol ; 128: 109040, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32442835

RESUMO

BACKGROUND: A precise assessment of cup version after hip resurfacing is generally requested, especially in clinical trials or in case of complications. AIMS: To identify which diagnostic imaging modality, between AP pelvis X-rays, the AP Pelvis CT Scout image and reduced-dose axial CT scan, is the most precise to assess cup version of an all-ceramic hip resurfacing implant in a first-in-human clinical trial. METHODS: We retrospectively assessed the cup version of the first 20 patients who underwent an experimental all-ceramic hip resurfacing on AP pelvis X-rays (0.8 mSv of radiation), AP pelvis CT scout images (0.016 mSv) and axial CT slices performed using a reduced dose protocol (0.3 mSv). The intra-observer and inter-observer reliabilities were calculated. RESULTS: Reduced dose Pelvis CT scan was the most precise imaging modality to detect cup version (Pearson Correlation Coefficient, PCC = 0.98, p < 0.001). The AP Pelvis CT Scout image was found to be sufficient to measure cup version within an acceptable margin of tolerance (mean difference ±â€¯4.7° from pelvis CT scan) and highly correlated to axial pelvis CT scan measurements (PCC 0.97, p < 0.001). Analysis of cup version from AP X-rays poorly correlated with measurements from Pelvis CT (PCC 0.59, p = 0.006). CONCLUSIONS: Due to lower radiation exposure and highest accuracy, reduced dose CT is a valid modality to measure acetabular cup version after ceramic hip resurfacing. Plain X-rays are not accurate nor precise to measure version, whereas high agreement of measurements between AP Pelvis CT Scout and axial pelvis CT scan was found.


Assuntos
Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Cerâmica , Feminino , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
20.
Am J Sports Med ; 48(4): 1000-1013, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31188642

RESUMO

BACKGROUND: Several devices for obtaining dynamic fixation of the syndesmosis have been introduced in recent years, but their efficacy has been tested in only a few randomized controlled trials (RCTs), without demonstrating any clear benefit over the traditional static fixation with screws. PURPOSE: To perform a level 1 meta-analysis of RCTs to investigate the complications, subjective outcomes, and functional results after dynamic or static fixation of acute syndesmotic injuries. STUDY DESIGN: Meta-analysis of RCTs. METHODS: A systematic literature search was performed of the Medline/PubMed, Cochrane Central Register of Controlled Trials, and Embase electronic databases, as well as ClinicalTrials.gov for unpublished studies. Eligible studies were RCTs comparing dynamic fixation and static fixation of acute syndesmosis injuries. A meta-analysis was performed, while bias and quality of evidence were rated according to the Cochrane Database questionnaire and the Grading of Recommendations Assessment, Development and Evaluation guidelines. RESULTS: Dynamic fixation had a significantly reduced relative risk (RR = 0.55, P = .003) of complications-in particular, the presence of inadequate reduction at the final follow-up (RR = 0.36, P = .0008) and the clinical diagnosis of recurrent diastasis or instability (RR = 0.10, P = .03). The effect was more evident when compared with permanent screws (RR = 0.10, P = .0001). The reoperation rate was similar between the groups (RR = 0.64, P = .07); however, the overall risk was reduced after dynamic fixation as compared with static fixation with permanent screws (RR = 0.24, P = .007). The American Orthopaedic Foot & Ankle Society score was significantly higher among patients treated with dynamic fixation-6.06 points higher (P = .005) at 3 months, 5.21 points (P = .03) at 12 months, and 8.60 points (P < .00001) at 24 months-while the Olerud-Molander score was similar. The visual analog scale for pain score was reduced at 6 months (-0.73 points, P = .003) and 12 months (-0.52 points, P = .005), and ankle range of motion increased by 4.36° (P = .03) with dynamic fixation. The overall quality of evidence ranged from "moderate" to "very low," owing to a substantial risk of bias, heterogeneity, indirectness of outcome reporting, and evaluation of a limited number of patients. CONCLUSION: The dynamic fixation of syndesmotic injuries was able to reduce the number of complications and improve clinical outcomes as compared with static screw fixation-especially malreduction and clinical instability or diastasis-at a follow-up of 2 years. A lower risk of reoperation was found with dynamic fixation as compared with static fixation with permanent screws. However, the lack of patients or personnel blinding, treatment heterogeneity, small samples, and short follow-up limit the overall quality of this evidence.


Assuntos
Traumatismos do Tornozelo , Fixação Interna de Fraturas , Traumatismos do Tornozelo/cirurgia , Parafusos Ósseos , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Reoperação , Técnicas de Sutura , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA