Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Br J Radiol ; 94(1119): 20201354, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33481637

RESUMO

OBJECTIVES: This multicentric study was carried out to investigate the impact of small field output factors (OFs) inaccuracies on the calculated dose in volumetric arctherapy (VMAT) radiosurgery brain plans. METHODS: Nine centres, realised the same five VMAT plans with common planning rules and their specific clinical equipment Linac/treatment planning system commissioned with their OFs measured values (OFbaseline). In order to simulate OFs errors, two new OFs sets were generated for each centre by changing only the OFs values of the smallest field sizes (from 3.2 × 3.2 cm2 to 1 × 1 cm2) with well-defined amounts (positive and negative). Consequently, two virtual machines for each centre were recommissioned using the new OFs and the percentage dose differences ΔD (%) between the baseline plans and the same plans recalculated using the incremented (OFup) and decremented (OFdown) values were evaluated. The ΔD (%) were analysed in terms of planning target volume (PTV) coverage and organs at risk (OARs) sparing at selected dose/volume points. RESULTS: The plans recalculated with OFdown sets resulted in higher variation of doses than baseline within 1.6 and 3.4% to PTVs and OARs respectively; while the plans with OFup sets resulted in lower variation within 1.3% to both PTVs and OARs. Our analysis highlights that OFs variations affect calculated dose depending on the algorithm and on the delivery mode (field jaw/MLC-defined). The Monte Carlo (MC) algorithm resulted significantly more sensitive to OFs variations than all of the other algorithms. CONCLUSION: The aim of our study was to evaluate how small fields OFs inaccuracies can affect the dose calculation in VMAT brain radiosurgery treatments plans. It was observed that simulated OFs errors, return dosimetric calculation accuracies within the 3% between concurrent plans analysed in terms of percentage dose differences at selected dose/volume points of the PTV coverage and OARs sparing. ADVANCES IN KNOWLEDGE: First multicentre study involving different Planning/Linacs about undetectable errors in commissioning output factor for small fields.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X/métodos , Encéfalo/diagnóstico por imagem , Simulação por Computador , Humanos , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Incerteza
2.
Pract Radiat Oncol ; 10(2): 125-132, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31786233

RESUMO

PURPOSE: To investigate the performance of various algorithms for deformable image registration (DIR) for propagating regions of interest (ROIs) using multiple commercial platforms, from computed tomography to cone beam computed tomography (CBCT) and megavoltage computed tomography. METHODS AND MATERIALS: Fourteen institutions participated in the study using 5 commercial platforms: RayStation (RaySearch Laboratories, Stockholm, Sweden), MIM (Cleveland, OH), VelocityAI and SmartAdapt (Varian Medical Systems, Palo Alto, CA), and ABAS (Elekta AB, Stockholm, Sweden). Algorithms were tested on synthetic images generated with the ImSimQA (Oncology Systems Limited, Shrewsbury, UK) package by applying 2 specific deformation vector fields (DVF) to real head and neck patient datasets. On-board images from 3 systems were used: megavoltage computed tomography from Tomotherapy and 2 kinds of CBCT from a clinical linear accelerator. Image quality of the system was evaluated. The algorithms' accuracy was assessed by comparing the DIR-mapped ROIs returned by each center with those of the reference, using the Dice similarity coefficient and mean distance to conformity metrics. Statistical inference on the validation results was carried out to identify the prognostic factors of DIR performance. RESULTS: Analyzing 840 DIR-mapped ROIs returned by the centers, it was demonstrated that DVF intensity and image quality were significant prognostic factors of DIR performance. The accuracy of the propagated contours was generally high, and acceptable DIR performance can be obtained with lower-dose CBCT image protocols. CONCLUSIONS: The performance of the systems proved to be image quality specific, depending on the DVF type and only partially on the platforms. All systems proved to be robust against image artifacts and noise, except the demon-based software.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos
3.
Med Phys ; 45(2): 748-757, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29266262

RESUMO

PURPOSE: To investigate the performance of various algorithms for deformable image registration (DIR) to propagate regions of interest (ROIs) using multiple commercial platforms. METHODS AND MATERIALS: Thirteen institutions participated in the study with six commercial platforms: RayStation (RaySearch Laboratories, Stockholm, Sweden), MIM (Cleveland, OH, USA), VelocityAI and Smart Adapt (Varian Medical Systems, Palo Alto, CA, USA), Mirada XD (Mirada Medical Ltd, Oxford, UK), and ABAS (Elekta AB, Stockholm, Sweden). The DIR algorithms were tested on synthetic images generated with the ImSimQA package (Oncology Systems Limited, Shrewsbury, UK) by applying two specific Deformation Vector Fields (DVF) to real patient data-sets. Head-and-neck (HN), thorax, and pelvis sites were included. The accuracy of the algorithms was assessed by comparing the DIR-mapped ROIs from each center with those of reference, using the Dice Similarity Coefficient (DSC) and Mean Distance to Conformity (MDC) metrics. Statistical inference on validation results was carried out in order to identify the prognostic factors of DIR performances. RESULTS: DVF intensity, anatomic site and participating center were significant prognostic factors of DIR performances. Sub-voxel accuracy was obtained in the HN by all algorithms. Large errors, with MDC ranging up to 6 mm, were observed in low-contrast regions that underwent significant deformation, such as in the pelvis, or large DVF with strong contrast, such as the clinical tumor volume (CTV) in the lung. Under these conditions, the hybrid DIR algorithms performed significantly better than the free-form intensity based algorithms and resulted robust against intercenter variability. CONCLUSIONS: The performances of the systems proved to be site specific, depending on the DVF type and the platforms and the procedures used at the various centers. The pelvis was the most challenging site for most of the algorithms, which failed to achieve sub-voxel accuracy. Improved reproducibility was observed among the centers using the same hybrid registration algorithm.


Assuntos
Processamento de Imagem Assistida por Computador/instrumentação , Imagens de Fantasmas , Algoritmos , Humanos , Tomografia Computadorizada por Raios X
4.
Phys Med ; 32(5): 735-40, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27136737

RESUMO

PURPOSE: To present our methods and results regarding the modeling of a carbon fiber couch (Varian Exact IGRT) in the RayStation treatment planning system (TPS). METHODS: Three geometrical-models (GMs) were implemented in the TPS to represent the three different regions of the couch (thick, medium and thin). The materials and densities of each GM component were tuned to maximize the agreement between measured and calculated attenuations. Moreover, a couch computed-tomography (CT) scan was acquired and dosimetrically compared with the GMs. For validation, plan-specific quality assurance (QA) of VMAT plans (TG-119 cases, 5 prostate and 5 H&N clinical cases) was performed by comparing measured dose distributions with doses computed with and without including the GMs in the TPS. RESULTS: Couch attenuations up to 4.3% were measured (energy: 6MV). Compared to couch CT, GMs could be modified to optimize the agreement with measurements and reduce dependence on the dose grid resolution. For both couch CT and GM, absolute deviations between measured and calculated attenuations were within 1.0%. When including the GMs in plan-specific QA, global 2%/2mm γ-pass rates showed an average improvement of 4.8% (p-value<0.001, max +18.6%). The couch reduced the mean dose to targets by up to 2.4% of the prescribed dose for prostate cases and up to 1.4% for H&N cases. CONCLUSIONS: RayStation accurately considers the implemented couch GMs replicating measured attenuations within an uncertainty of 1.0%. Materials and densities are proposed for the Varian Exact IGRT couch. The results obtained justify introducing couch GMs in clinical routine.


Assuntos
Neoplasias da Próstata/radioterapia , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Carbono/química , Fibra de Carbono , Humanos , Masculino , Modelos Estatísticos , Neoplasias/radioterapia , Imagens de Fantasmas , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Software , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA