Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur J Vasc Endovasc Surg ; 62(1): 55-63, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33965329

RESUMO

OBJECTIVE: To report the intra-operative adverse events (IOAEs) and the initial and one year outcomes of retrograde open mesenteric stenting (ROMS) using balloon expandable covered stents for acute and chronic mesenteric ischaemia. METHODS: Clinical data and outcomes of all consecutive patients treated with ROMS for acute and chronic mesenteric ischaemia at an intestinal stroke centre between November 2012 and September 2019 were reviewed. ROMS was performed using balloon expandable covered stents. Endpoints included IOAEs, in hospital mortality, post-operative complications, and re-interventions. One year overall survival, freedom from re-intervention, primary patency and assisted primary patency rates were analysed using the Kaplan-Meier time to event method. RESULTS: During the study period, 379 patients were referred to the centre for acute or chronic mesenteric ischaemia. Thirty-seven patients who underwent the ROMS procedure were included. All the patients had severe atherosclerotic mesenteric lesions. The ROMS technical success rate was 89% in this cohort. The rate of IOAEs was 19% and included four cases of retrograde recanalisation failure. All ROMS failures occurred in patients presenting with flush superior mesenteric artery occlusion and they were treated by mesenteric bypass. Ten patients (27%) underwent bowel resection, four of which resulted in a short bowel syndrome (11%). The in hospital mortality rate was 27%. Post-operative complications and re-intervention rates were 67% (n = 25) and 32% (n = 12), respectively. The median follow up was 20.2 months (interquartile range 29). The estimated one year overall survival for the cohort was 70.1% (95% confidence interval [CI] 52.5% - 82.2%). The estimated freedom from re-intervention at one year was 61.1% (95% CI 42.3 - 75.4). The one year primary patency and assisted primary patency rates were 84.54% (95% CI 63.34 - 94) and 92.4% (95% CI 72.8 - 98), respectively. CONCLUSION: ROMS procedures offer acceptable one year outcomes for mesenteric ischaemia but are associated with frequent stent related complications. Precise pre-operative planning, high quality imaging, and meticulous stent placement techniques may limit the occurrence of such events.


Assuntos
Procedimentos Endovasculares/efeitos adversos , Complicações Intraoperatórias/epidemiologia , Isquemia Mesentérica/cirurgia , Oclusão Vascular Mesentérica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Doença Aguda/mortalidade , Doença Aguda/terapia , Idoso , Doença Crônica/mortalidade , Doença Crônica/terapia , Procedimentos Endovasculares/instrumentação , Estudos de Viabilidade , Feminino , Mortalidade Hospitalar , Humanos , Complicações Intraoperatórias/etiologia , Masculino , Artérias Mesentéricas/diagnóstico por imagem , Artérias Mesentéricas/patologia , Artérias Mesentéricas/cirurgia , Isquemia Mesentérica/diagnóstico , Isquemia Mesentérica/mortalidade , Oclusão Vascular Mesentérica/diagnóstico , Oclusão Vascular Mesentérica/mortalidade , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Stents/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA