Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 280
Filtrar
1.
Eur Radiol ; 33(2): 1318-1328, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36074261

RESUMO

OBJECTIVES: To assess the impact of dual-energy CT (DECT) utilization in practice by measuring the readers' confidence, the need for additional image requests, and diagnostic performance in renal lesion assessment, compared to single-energy CT (SECT) using contrast-enhanced MRI to establish the reference standard. MATERIALS AND METHODS: Sixty-nine patients (M/F = 47/22) who underwent a dual-phase renal SECT (n = 34) or DECT (n = 35) and had a contrast-enhanced MRI within 180 days were retrospectively collected. Three radiologists assessed images on different sessions (SECT, DECT, and MRI) for (1) likely diagnosis (enhancing/non-enhancing); (2) diagnostic confidence (5-point Likert scale); (3) need for additional imaging test (yes/no); and (4) need for follow-up imaging (yes/no). Diagnostic accuracy was compared using AUC; p value < 0.05 was considered significant. RESULTS: One hundred fifty-six lesions consisting of 18% enhancing (n = 28/156, mean size: 30.37 mm, range: 9.9-94 mm) and 82% non-enhancing (n = 128/156, mean size: 23.91 mm, range: 5.0-94.2 mm) were included. The confidence level was significantly lower for SECT than their MRI (4.50 vs. 4.80, p value < 0.05) but not significantly different for DECT and the corresponding MRI (4.78 vs. 4.78, p > 0.05). There were significantly more requests for additional imaging in the SECT session than the corresponding MRI (20% vs. 4%), which was not significantly different between DECT and their MRI counterpart session (5.7% vs. 4.9%). Inter-reader agreement was almost perfect for DECT and MRI (kappa: 0.8-1) and substantial in SECT sessions (kappa: 0.6-0.8) with comparable diagnostic accuracy between SECT, DECT, and MRI (p value > 0.05). CONCLUSION: Single-phase DECT allows confident and reproducible characterization of renal masses with fewer recommendation for additional and follow-up imaging tests than dual-phase SECT and a performance similar to MRI. KEY POINTS: • DECT utilization leads to similar additional image requests to MRI (5.7% vs. 4.9%, p value > 0.05), whereas single-energy CT utilization leads to significantly higher image requests (20% vs. 4%, p value < 0.05). • DECT and MRI utilization bring highly reproducible results with almost perfect inter-reader agreement (kappa: 0.8-1), better than the inter-reader agreement in SECT utilization (kappa: 0.6-0.8). • Readers' confidence was not significantly altered between DECT and their MRI readout session (p value > 0.05). In contrast, confidence in the diagnosis was significantly lower in the SECT session than their MRI readout (p value < 0.05).


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estudos Retrospectivos , Doses de Radiação , Imageamento por Ressonância Magnética
2.
AJR Am J Roentgenol ; 219(4): 614-623, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35441533

RESUMO

BACKGROUND. Prior studies have provided mixed results for the ability to replace true unenhanced (TUE) images with virtual unenhanced (VUE) images when characterizing renal lesions by dual-energy CT (DECT). Detector-based dual-layer DECT (dlDECT) systems may optimize performance of VUE images for this purpose. OBJECTIVE. The purpose of this article was to compare dual-phase dlDECT examinations evaluated using VUE and TUE images in differentiating cystic and solid renal masses. METHODS. This retrospective study included 110 patients (mean age, 64.3 ± 11.8 years; 46 women, 64 men) who underwent renal-mass protocol dlDECT between July 2018 and February 2022. TUE, VUE, and nephrographic phase image sets were reconstructed. Lesions were diagnosed as solid masses by histopathology or MRI. Lesions were diagnosed as cysts by composite criteria reflecting findings from MRI, ultrasound, and the TUE and nephrographic phase images of the dlDECT examinations. One radiologist measured lesions' attenuation on all dlDECT image sets. Lesion characterization was compared between use of VUE and TUE images, including when considering enhancement of 20 HU or greater to indicate presence of a solid mass. RESULTS. The analysis included 219 lesions (33 solid masses; 186 cysts [132 simple, 20 septate, 34 hyperattenuating]). TUE and VUE attenuation were significantly different for solid masses (33.4 ± 7.1 HU vs 35.4 ± 8.6 HU, p = .002), simple cysts (10.8 ± 5.6 HU vs 7.1 ± 8.1 HU, p < .001), and hyperattenuating cysts (56.3 ± 21.0 HU vs 47.6 ± 16.3 HU, p < .001), but not septate cysts (13.6 ± 8.1 HU vs 14.0 ± 6.8 HU, p = .79). Frequency of enhancement 20 HU or greater when using TUE and VUE images was 90.9% and 90.9% in solid masses, 0.0% and 9.1% in simple cysts, 15.0% and 10.0% in septate cysts, and 11.8% and 38.2% in hyperattenuating cysts. All solid lesions were concordant in terms of enhancement 20 HU or greater when using TUE and VUE images. Twelve simple cysts and nine hyperattenuating cysts showed enhancement of 20 HU or greater when using VUE but not TUE images. CONCLUSION. Use of VUE images reliably detected enhancement in solid masses. However, VUE images underestimated attenuation of simple and hyperattenuating cysts, leading to false-positive findings of enhancement by such lesions. CLINICAL IMPACT. The findings do not support replacement of TUE acquisitions with VUE images when characterizing renal lesions by dlDECT.


Assuntos
Cistos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Idoso , Meios de Contraste , Feminino , Humanos , Aumento da Imagem , Rim , Masculino , Pessoa de Meia-Idade , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
3.
Radiographics ; 41(1): 98-119, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33411614

RESUMO

Dual-energy CT (DECT) is a tremendous innovation in CT technology that allows creation of numerous imaging datasets by enabling discrete acquisitions at more than one energy level. The wide range of images generated from a single DECT acquisition provides several benefits such as improved lesion detection and characterization, superior determination of material composition, reduction in the dose of iodine, and more robust quantification. Technological advances and the proliferation of various processing methods have led to the availability of diverse vendor-based DECT approaches, each with a different acquisition and image reconstruction process. The images generated from various DECT scanners differ from those from conventional single-energy CT because of differences in their acquisition techniques, material decomposition methods, image reconstruction algorithms, and postprocessing methods. DECT images such as virtual monochromatic images, material density images, and virtual unenhanced images have different imaging appearances, texture features, and quantitative capabilities. This heterogeneity creates challenges in their routine interpretation and has certain associated pitfalls. Some artifacts such as residual iodine on virtual unenhanced images and an appearance of pseudopneumatosis in a gas-distended bowel loop on material-density iodine images are specific to DECT, while others such as pseudoenhancement seen on virtual monochromatic images are also observed at single-energy CT. Recognizing the potential pitfalls associated with DECT is necessary for appropriate and accurate interpretation of the results of this increasingly important imaging tool. Online supplemental material is available for this article. ©RSNA, 2021.


Assuntos
Iodo , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Artefatos , Humanos , Processamento de Imagem Assistida por Computador , Tomografia Computadorizada por Raios X
4.
Radiographics ; 41(2): 509-523, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33606565

RESUMO

Dual-energy CT (DECT) is an exciting innovation in CT technology with profound capabilities to improve diagnosis and add value to patient care. Significant advances in this technology over the past decade have improved our ability to successfully adopt DECT into the clinical routine. To enable effective use of DECT, one must be aware of the pitfalls and artifacts related to this technology. Understanding the underlying technical basis of artifacts and the strategies to mitigate them requires optimization of scan protocols and parameters. The ability of radiologists and technologists to anticipate their occurrence and provide recommendations for proper selection of patients, intravenous and oral contrast media, and scan acquisition parameters is key to obtaining good-quality DECT images. In addition, choosing appropriate reconstruction algorithms such as image kernel, postprocessing parameters, and appropriate display settings is critical for preventing quantitative and qualitative interpretive errors. Therefore, knowledge of the appearances of these artifacts is essential to prevent errors and allows maximization of the potential of DECT. In this review article, the authors aim to provide a comprehensive and practical overview of possible artifacts that may be encountered at DECT across all currently available commercial clinical platforms. They also provide a pictorial overview of the diagnostic pitfalls and outline strategies for mitigating or preventing the occurrence of artifacts, when possible. The broadening scope of DECT applications necessitates up-to-date familiarity with these technologies to realize their full diagnostic potential.


Assuntos
Artefatos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Algoritmos , Meios de Contraste , Humanos , Tomografia Computadorizada por Raios X
5.
Radiology ; 296(2): E26-E31, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32687455

RESUMO

The coronavirus disease 2019 (COVID-19) pandemic initially manifested in the United States in the greater Seattle area and has rapidly progressed across the nation in the past 2 months, with the United States having the highest number of cases in the world. Radiology departments play a critical role in policy and guideline development both for the department and for the institutions, specifically in planning diagnostic screening, triage, and management of patients. In addition, radiology workflows, volumes, and access must be optimized in preparation for the expected surges in the number of patients with COVID-19. In this article, the authors discuss the processes that have been implemented at the University of Washington in managing the COVID-19 pandemic as well in preparing for patient surges, which may provide important guidance for other radiology departments who are in the early stages of preparation and management.


Assuntos
Betacoronavirus , Infecções por Coronavirus/diagnóstico por imagem , Controle de Infecções/organização & administração , Pneumonia Viral/diagnóstico por imagem , Serviço Hospitalar de Radiologia/organização & administração , Poluentes Ocupacionais do Ar/análise , COVID-19 , Teste para COVID-19 , Técnicas de Laboratório Clínico/métodos , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/prevenção & controle , Infecções por Coronavirus/transmissão , Política de Saúde , Humanos , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Programas de Rastreamento/métodos , Pandemias/prevenção & controle , Equipamento de Proteção Individual , Pneumonia Viral/epidemiologia , Pneumonia Viral/prevenção & controle , Pneumonia Viral/transmissão , Guias de Prática Clínica como Assunto , SARS-CoV-2 , Washington
6.
Radiology ; 296(2): E26-E31, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32267209

RESUMO

The coronavirus disease 2019 (COVID-19) pandemic initially manifested in the United States in the greater Seattle area and has rapidly progressed across the nation in the past 2 months, with the United States having the highest number of cases in the world. Radiology departments play a critical role in policy and guideline development both for the department and for the institutions, specifically in planning diagnostic screening, triage, and management of patients. In addition, radiology workflows, volumes, and access must be optimized in preparation for the expected surges in the number of patients with COVID-19. In this article, the authors discuss the processes that have been implemented at the University of Washington in managing the COVID-19 pandemic as well in preparing for patient surges, which may provide important guidance for other radiology departments who are in the early stages of preparation and management.


Assuntos
COVID-19 , Política de Saúde , COVID-19/diagnóstico , COVID-19/terapia , Planejamento em Desastres , Hospitalização , Hospitais Universitários , Humanos , Pandemias , Guias de Prática Clínica como Assunto , Serviço Hospitalar de Radiologia/legislação & jurisprudência , Serviço Hospitalar de Radiologia/organização & administração , Serviço Hospitalar de Radiologia/estatística & dados numéricos , SARS-CoV-2 , Washington
7.
Eur J Nucl Med Mol Imaging ; 47(8): 1871-1884, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31705172

RESUMO

PURPOSE: Intrahepatic cholangiocarcinoma (ICC) is associated with a poor prognosis with surgical resection offering the best chance for long-term survival and potential cure. However, in up to 36% of patients who undergo surgery, more extensive disease is found at time of operation requiring cancellation of surgery. PET/MR is a novel hybrid technology that might improve local and whole-body staging in ICC patients, potentially influencing clinical management. This study was aimed to investigate the possible management implications of PET/MR, relative to conventional imaging, in patients affected by untreated intrahepatic cholangiocarcinoma. METHODS: Retrospective review of the clinicopathologic features of 37 patients with iCCC, who underwent PET/MR between September 2015 and August 2018, was performed to investigate the management implications that PET/MR had exerted on the affected patients, relative to conventional imaging. RESULTS: Of the 37 patients enrolled, median age 63.5 years, 20 (54%) were female. The same day PET/CT was performed in 26 patients. All patients were iCCC-treatment-naïve. Conventional imaging obtained as part of routine clinical care demonstrated early-stage resectable disease for 15 patients and advanced stage disease beyond the scope of surgical resection for 22. PET/MR modified the clinical management of 11/37 (29.7%) patients: for 5 patients (13.5%), the operation was cancelled due to identification of additional disease, while 4 "inoperable" patients (10.8%) underwent an operation. An additional 2 patients (5.4%) had a significant change in their operative plan based on PET/MR. CONCLUSIONS: When compared with standard imaging, PET/MR significantly influenced the treatment plan in 29.7% of patients with iCCC. TRIAL REGISTRATION: 2018P001334.


Assuntos
Neoplasias dos Ductos Biliares , Colangiocarcinoma , Neoplasias dos Ductos Biliares/diagnóstico por imagem , Neoplasias dos Ductos Biliares/patologia , Neoplasias dos Ductos Biliares/cirurgia , Colangiocarcinoma/diagnóstico por imagem , Colangiocarcinoma/patologia , Feminino , Fluordesoxiglucose F18 , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Estudos Retrospectivos
8.
Radiology ; 291(3): 620-629, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30964423

RESUMO

Background Substantial gain in the attenuation of iodine on low-kVp and dual-energy CT processed low-keV virtual monochromatic images provides an opportunity for customization of positive oral contrast media administration. Purpose To perform an intrapatient comparison of bowel labeling, opacification, and taste preference with iodinated oral contrast medium (ICM) in standard (sICM) and 25%-reduced (rICM) concentrations at low tube voltage (100 kVp) or on low-energy (50-70 keV) virtual monochromatic images compared with barium-based oral contrast medium (BCM) at 120 kVp. Materials and Methods In this prospective clinical trial, 200 adults (97 men, 103 women; mean age, 63 years ± 13 [standard deviation]) who weighed less than 113 kg and who were undergoing oncologic surveillance (from April 2017 to July 2018) and who had previously undergone 120-kVp abdominopelvic CT with BCM randomly received sICM (7.2 g iodine) or rICM (5.4 g iodine) and underwent 100-kVp CT or dual-energy CT (80/140 kVp) scans to be in one of four groups (n = 50 each): sICM/100 kVp, rICM/100 kVp, sICM/dual-energy CT, and rICM/dual-energy CT. Qualitative analysis was performed for image quality (with a five-point scale), extent of bowel labeling, and homogeneity of opacification (with a four-point scale). Intraluminal attenuation of opacified small bowel was measured. A post-CT patient survey was performed to indicate contrast medium preference, taste of ICM (with a five-point scale), and adverse effects. Data were analyzed with analogs of analysis of variance. Results All CT studies were of diagnostic image quality (3.4 ± 0.3), with no difference in the degree of bowel opacification between sICM and rICM (P > .05). Compared with BCM/120 kVp (282 HU ± 73), mean attenuation was 78% higher with sICM/100 kVp (459 HU ± 282) and 26%-121% higher at sICM/50-65 keV (50 keV = 626 HU ± 285; 65 keV = 356 HU ± 171). With rICM, attenuation was 46% higher for 100 kVp (385 HU ± 215) and 19%-108% higher for 50-65 keV (50 keV = 567 HU ± 270; 65 keV = 325 HU ± 156) compared with BCM (P < .05). A total of 171 of 200 study participants preferred ICM to BCM, with no taste differences between sICM and rICM (3.9 ± 0.6). Fifteen participants had diarrhea with BCM, but none had diarrhea with ICM. Conclusion A 25%-reduced concentration of iodinated oral contrast medium resulted in acceptable bowel labeling while yielding substantially higher luminal attenuation at low-kVp and low-keV CT examinations with improved preference in patients undergoing treatment for cancer. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Laghi in this issue.


Assuntos
Meios de Contraste , Neoplasias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Bário/administração & dosagem , Bário/efeitos adversos , Meios de Contraste/administração & dosagem , Meios de Contraste/efeitos adversos , Meios de Contraste/química , Diarreia , Feminino , Humanos , Iodo/administração & dosagem , Iodo/efeitos adversos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia Abdominal , Tomografia Computadorizada por Raios X/efeitos adversos
9.
Eur Radiol ; 29(11): 5852-5860, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30888485

RESUMO

OBJECTIVE: To assess the lesion detection performance of an abbreviated MRI (AMRI-M) protocol consisting of ultrafast SE T2W, DWI, and T1W-HBP at 20 min for colorectal liver metastasis (CRLM) surveillance. METHODS: In this Institutional Review Board (IRB)-approved retrospective study, gadoxetic acid-enhanced MRI scans of 57 patients (43 with pathologically proven CRLMs) were assessed. Two readers independently evaluated two sets of images per patient and commented on the number, location, and size of liver lesions. Set 1 included ultrafast spin-echo (SE) T2-weighted (T2W) + T1-weighted (T1W) hepatobiliary phase (HBP) at 20 min sequences + diffusion-weighted imaging (DWI), and set 2 consisted of the standard MRI protocol. A maximum of 10 lesions per patient were recorded. Cohen's kappa analysis, sensitivity, areas under the curve (AUCs), and the MRI cost analysis of the AMRI-M protocol were assessed. RESULTS: Between 198 and 209 lesions were assessed with each set of images. The inter-observer agreement for the abbreviated protocol was reported excellent (κ = 0.91). The sensitivity and AUCs for the lesion characterization of AMRI-M protocol were very high (over 90%) for both readers. No statistically significant differences in sensitivity (assessed by mixed-effects logistic regression) and AUCs for lesion characterization (by ROC regression) were found between both protocols. The AMRI-M acquisition time was estimated to be less than 10 min, which translated into 59% cost of standard MRI. CONCLUSION: Our proposed AMRI-M protocol (ultrafast SE T2W, DWI, and T1W-HBP at 20 min) is fast, low-cost alternative to the standard MRI protocol and has a high lesion detection performance. KEY POINTS: • Gadoxetic acid-enhanced protocol has increased the accuracy, sensitivity, and specificity of MRI for detecting colorectal liver metastases. • Our proposed abbreviated MRI protocol is fast, low-cost alternative compared with the standard MRI protocol and has a high lesion detection performance. • Adoption of our protocol may translate to substantial savings for patients and payers.


Assuntos
Neoplasias Colorretais/patologia , Gadolínio DTPA/farmacologia , Neoplasias Hepáticas/diagnóstico , Imageamento por Ressonância Magnética/métodos , Estadiamento de Neoplasias/métodos , Meios de Contraste/farmacologia , Feminino , Humanos , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos
10.
AJR Am J Roentgenol ; 212(2): 467-474, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30476460

RESUMO

OBJECTIVE: The purpose of this study was to assess the feasibility of performing abdominopelvic aortoiliac CT angiography (CTA) with 16.0 g of iodine contrast medium acquired with low-energy (40 and 50 keV) virtual monochromatic (VMC) images with rapid-kilovoltage-switching dual-energy CT. SUBJECTS AND METHODS: A total of 52 adults with abdominal aortoiliac aneurysm and prior 120-kVp single-energy CTA (SECTA) with 33 g iodine (standard dose) underwent follow-up dual-energy CTA (DECTA) with a 52% reduced iodine dose. Subjects were randomly assigned to a contrast medium protocol for DECTA examinations: one group (n = 26) received 16.2 g (270 mg I/mL) and the other (n = 26) received 16.0 g (320 mg I/mL). Two readers independently assessed SECTA and VMC DECTA datasets for image quality using a 5-point scale. Aortoiliac intravascular attenuation was measured, and ANOVA was used to compare measurements between VMC DECTA and SECTA images. In a subset of patients with DECTA after endovascular aortic repair, endoleak detection was evaluated on VMC images. Volume CT dose index, dose-length product, and size-specific dose estimate were compared between DECTA and SECTA. RESULTS: All DECTA examinations (n = 52) were rated diagnostic with image quality scores comparable to those of 120-kVp single-energy CTA (40 keV, 4.2-4.4; 50 keV, 4.6-4.8; SECTA, 4.4-4.5). Intravascular attenuation was uniform in all reduced-iodine DECTA examinations and was significantly higher on 40- and 50-keV images than on standard-iodine-dose SECTA images (720 ± 125 HU and 482 ± 82 HU vs 303 ± 65 HU) (p < 0.01). There was no difference in intravascular attenuation between the 16.2-g and the 16.0-g doses (p = 0.82). Sensitivity and specificity for endoleak detection were 78.9-94.7% and 100%. Total dose-length product was lower for DECTA (788 ± 166 mGy · cm) than for SECTA (1114 ± 468 mGy · cm). CONCLUSION: Low-energy VMC DECTA images (40 and 50 keV) acquired with two contrast protocols at approximately 50% reduced iodine dose (16.0 and 16.2 g) provide adequate intravascular attenuation and diagnostic quality for aortoiliac evaluation.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Artéria Ilíaca/diagnóstico por imagem , Compostos de Iodo/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton
11.
AJR Am J Roentgenol ; 212(4): 796-801, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30673342

RESUMO

OBJECTIVE: The objective of our study was to investigate the impact of large body habitus on dual-energy CT (DECT) image quality and stone characterization. MATERIALS AND METHODS: We retrospectively included 105 consecutive patients with large body habitus (> 90 kg) who underwent stone protocol DECT between 2015 and 2017. The evaluation of DECT datasets was performed for image quality assessment based on European Guidelines on Quality Criteria for Computed Tomography and for determination of stone composition (i.e., uric acid vs non-uric acid). Correlation between DECT characterization and crystallography results was performed when available. The cohort was divided into two groups on the basis of body weight (≤ 104 kg and > 104 kg), and comparisons were made for image quality and stone characterization. RESULTS: One hundred ninety-seven urinary tract calculi (size: mean ± SD, 5.7 ± 5.3 mm; range, 1.4-56 mm) were detected in 73% (79/108) of examinations in 105 patients (weight: mean ± SD, 104.0 ± 12.7 kg; range, 91-163 kg). The overall mean image quality score of blended images and color maps was 3.7 and 3.9, respectively, and the effective dual-energy FOV limitation did not hamper stone characterization. The diagnostic acceptability scores of blended images and color maps were slightly lower in patients weighing > 104 kg than in patients ≤ 104 kg (mean scores [highest score, 4 points]: blended images, 3.62 vs 3.82 [p = 0.0314]; color maps, 3.75 vs 3.98 [p = 0.0034]), but the scores were within acceptable range. Stone characterization as uric acid versus non-uric acid was achieved in 80% (158/197) of calculi (size: mean ± SD, 6.4 ± 5.7 mm; range, 1.6-56 mm), and DECT stone characterization was (95.6%) accurate with reference to crystallography. Twenty percent (39/197) of calculi could not be characterized on DECT, and these calculi were significantly smaller in size (size: mean ± SD, 2.8 ± 1.4 mm; range, 1.4-8.2 mm; p < 0.001) than those that could be characterized. The mean size of uncharacterized calculi was slightly larger in patients weighing > 104 kg (3.3 ± 1.6 mm) than in those weighing ≤ 104 kg (2.2 ± 0.6 mm). CONCLUSION: In patients with large body habitus, dual-source DECT provides acceptable image quality and allows characterization of almost all clinically significant calculi.


Assuntos
Obesidade/complicações , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Urolitíase/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Cálculos Urinários/química
12.
Radiographics ; 39(3): 744-758, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30901285

RESUMO

Technical advances in MRI have improved image quality and have led to expanding clinical indications for its use. However, long examination and interpretation times, as well as higher costs, still represent barriers to use of MRI. Abbreviated MRI protocols have emerged as an alternative to standard MRI protocols. These abbreviated MRI protocols seek to reduce longer MRI protocols by eliminating unnecessary or redundant sequences that negatively affect cost, MRI table time, patient comfort, image quality, and image interpretation time. However, the diagnostic information is generally not compromised. Abbreviated MRI protocols have already been used successfully for hepatocellular carcinoma screening, for prostate cancer detection, and for screening for nonalcoholic fatty liver disease as well as monitoring patients with this disease. It has been reported that image acquisition time and costs can be considerably reduced with abbreviated MRI protocols, compared with standard MRI protocols, while maintaining a similar sensitivity and accuracy. Nevertheless, multiple applications still need to be explored in the abdomen and pelvis (eg, surveillance of metastases to the liver; follow-up of cystic pancreatic lesions, adrenal incidentalomas, and small renal masses; evaluation of ovarian cysts in postmenopausal women; staging of cervical and uterine corpus neoplasms; evaluation of müllerian duct anomalies). This article describes some successful applications of abbreviated MRI protocols, demonstrates how they can help in improving the MRI workflow, and explores potential future directions. ©RSNA, 2019.


Assuntos
Abdome/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/secundário , Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Protocolos Clínicos , Neoplasias Colorretais , Feminino , Neoplasias dos Genitais Femininos/diagnóstico por imagem , Humanos , Rim/diagnóstico por imagem , Fígado/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Imageamento por Ressonância Magnética/economia , Imageamento por Ressonância Magnética/tendências , Masculino , Pessoa de Meia-Idade , Pâncreas/diagnóstico por imagem , Pancreatopatias/diagnóstico por imagem , Assistência Centrada no Paciente , Neoplasias da Próstata/diagnóstico por imagem
13.
Gastroenterology ; 153(5): 1284-1294.e1, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28739282

RESUMO

BACKGROUND & AIMS: Little is known about the development of branch duct intraductal papillary mucinous neoplasms (BD-IPMNs). We evaluated long-term outcomes of a large cohort of patients with BD-IPMNs to determine risk of malignancy and define a subset of low-risk BD-IPMNs. METHODS: We performed a retrospective analysis of data from 577 patients with suspected or presumed BD-IPMN under surveillance at the Massachusetts General Hospital. Patients underwent cross-sectional imaging analysis at 3 months or later after their initial diagnosis. The diagnosis of BD-IPMN was based on the presence of unilocular or multilocular cysts of the pancreas and a non-dilated main pancreatic duct (<5 mm). We collected demographic, clinical, and pathology data. Cysts were characterized at the time of diagnosis and during the follow-up period. Follow-up duration was time between initial cyst diagnosis and date of last visit or death for patients without development of pancreatic cancer, date of surgery for patients with histologically confirmed malignancy, or date of first discovery of malignancy by imaging analysis for patients with unresectable tumors or who underwent neoadjuvant treatment before surgery. The primary outcome was risk of malignancy, with a focus on patients followed for 5 years or more, compared with that of the US population, based on standardized incidence ratio. RESULTS: Of the 577 patients studied, 479 (83%) were asymptomatic at diagnosis and 363 (63%) underwent endoscopic ultrasound at least once. The median follow-up time was 82 months (range, 6-329 months) for the entire study cohort; 363 patients (63%) underwent surveillance for more than 5 years, and 121 (21%) for more than 10 years. Malignancies (high-grade dysplasia or invasive neoplasm) developed after 5 years in 20 of 363 patients (5.5%), and invasive cancer developed in 16 of 363 patients (4.4%). The standardized incidence ratio for patients with BD-IPMNs without worrisome features of malignancy at 5 years was 18.8 (95% confidence interval, 9.7-32.8; P < .001). One hundred and eight patients had cysts ≤1.5 cm for more than 5 years of follow-up; only 1 of these patients (0.9%) developed a distinct ductal adenocarcinoma. By contrast, among the 255 patients with cysts >1.5 cm, 19 (7.5%) developed malignancy (P = .01). CONCLUSIONS: In a retrospective analysis of patients with BD-IPMNs under surveillance, their overall risk of malignancy, almost 8%, lasted for 10 years or more, supporting continued surveillance after 5 years. Cysts that remain ≤1.5 cm for more than 5 years might be considered low-risk for progression to malignancy.


Assuntos
Carcinoma Ductal Pancreático/patologia , Transformação Celular Neoplásica/patologia , Neoplasias Císticas, Mucinosas e Serosas/patologia , Cisto Pancreático/patologia , Ductos Pancreáticos/patologia , Neoplasias Pancreáticas/patologia , Encaminhamento e Consulta , Adulto , Idoso , Idoso de 80 Anos ou mais , Boston/epidemiologia , Carcinoma Ductal Pancreático/diagnóstico por imagem , Carcinoma Ductal Pancreático/epidemiologia , Feminino , Hospitais Gerais , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Neoplasias Císticas, Mucinosas e Serosas/diagnóstico por imagem , Neoplasias Císticas, Mucinosas e Serosas/epidemiologia , Cisto Pancreático/diagnóstico por imagem , Cisto Pancreático/epidemiologia , Ductos Pancreáticos/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/epidemiologia , Prognóstico , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Adulto Jovem
14.
Eur Radiol ; 28(7): 2745-2755, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29404773

RESUMO

OBJECTIVES: Evaluation of imaging performance across dual-energy CT (DECT) platforms, including dual-layer CT (DLCT), rapid-kVp-switching CT (KVSCT) and dual-source CT (DSCT). METHODS: A semi-anthropomorphic abdomen phantom was imaged on these DECT systems. Scans were repeated three times for CTDIvol levels of 10 mGy, 20 mGy, 30 mGy and different fat-simulating extension rings. Over the available range of virtual-monoenergetic images (VMI), noise as well as quantitative accuracy of hounsfield units (HU) and iodine concentrations were evaluated. RESULTS: For all VMI levels, HU values could be determined with high accuracy compared to theoretical values. For KVSCT and DSCT, a noise increase was observed towards lower VMI levels. A patient-size dependent increase in the uncertainty of quantitative iodine concentrations is observed for all platforms. For a medium patient size the iodine concentration root-mean-square deviation at 20 mGy is 0.17 mg/ml (DLCT), 0.30 mg/ml (KVSCT) and 0.77mg/ml (DSCT). CONCLUSION: Noticeable performance differences are observed between investigated DECT systems. Iodine concentrations and VMI HUs are accurately determined across all DECT systems. KVSCT and DLCT deliver slightly more accurate iodine concentration values than DSCT for investigated scenarios. In DLCT, low-noise and high-image contrast at low VMI levels may help to increase diagnostic information in abdominal CT. KEY POINTS: • Current dual-energy CT platforms provide accurate, reliable quantitative information. • Dual-energy CT cross-platform evaluation revealed noticeable performance differences between different systems. • Dual-layer CT offers constant noise levels over the complete energy range.


Assuntos
Imagens de Fantasmas , Radiografia Abdominal/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Abdome/diagnóstico por imagem , Antropometria/métodos , Desenho de Equipamento , Humanos , Iodo
15.
AJR Am J Roentgenol ; 210(3): 657-662, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29323550

RESUMO

OBJECTIVE: This study assessed radiation dose after CT-guided percutaneous radiofrequency ablations (RFAs) of hepatic and renal tumors and the effect of weight-based CT protocol modification for lowering overall dose in these procedures. MATERIALS AND METHODS: CT-guided RFA for renal and hepatic ablations performed from January 1, 2009, through December 31, 2009, were retrospectively reviewed (90 men and 48 women; age, 42-81 years). The radiation dose was recorded during each of the following steps: planning, performing, and postprocedure. Weight-based protocol modification changes in tube voltage and tube current were then applied to renal and hepatic ablations performed subsequently (18 men and 11 women; age, 48-82 years). Image quality, needle localization, lesion detection, ability to detect complications, and overall operator satisfaction were noted for each case (score, 1-5). Dose reduction after modification was then calculated. RESULTS: Retrospective analysis found a mean (± SD) overall CT dose index (CTDI) for CT-guided RFA to be 16.5 ± 2.3 mGy. After protocol modification, the mean CTDI decreased to 6.63 ± 0.67 mGy, a 59.6% reduction overall; for hepatic ablations, the reduction was 65.96% (p < 0.0001) and the reduction for renal ablations was 38.97% (p = 0.0153). Image quality analysis showed high operator satisfaction (3-5), including adequate needle localization (4-5), lesion visibility (3-5), and high performer confidence (4-5). Higher dose reduction was noted for patients weighing more than 180 lb (82 kg) (p < 0.0001). CONCLUSION: Simple weight-based CT protocol modifications can significantly reduce radiation dose during CT-guided percutaneous ablations in the liver and kidneys without significantly sacrificing image quality.


Assuntos
Ablação por Cateter/métodos , Neoplasias Renais/cirurgia , Neoplasias Hepáticas/cirurgia , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos
16.
AJR Am J Roentgenol ; 210(2): 341-346, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29140113

RESUMO

OBJECTIVE: The purposes of this study were to assess whether CT texture analysis and CT features are predictive of pancreatic neuroendocrine tumor (PNET) grade based on the World Health Organization (WHO) classification and to identify features related to disease progression after surgery. MATERIALS AND METHODS: Preoperative contrast-enhanced CT images of 101 patients with PNETs were assessed. The images were evaluated for tumor location, tumor size, tumor pattern, predominantly solid or cystic composition, presence of calcification, presence of heterogeneous enhancement on contrast-enhanced images, presence of pancreatic duct dilatation, presence of pancreatic atrophy, presence of vascular involvement by the tumor, and presence of lymphadenopathy. Texture features were also extracted from CT images. Surgically verified tumors were graded according to the WHO classification, and patients underwent CT or MRI follow-up after surgical resection. Data were analyzed with chi-square tests, kappa statistics, logistic regression analysis, and Kaplan-Meier curves. RESULTS: The CT features predictive of a more aggressive tumor (grades 2 and 3) were size larger than 2.0 cm (odds ratio [OR], 3.3; p = 0.014), presence of vascular involvement (OR, 25.2; p = 0.003), presence of pancreatic ductal dilatation (OR, 6.0; p = 0.002), and presence of lymphadenopathy (OR, 6.8; p = 0.002). The texture parameter entropy (OR, 3.7; p = 0.008) was also predictive of more aggressive tumors. Differences in progression-free survival distribution were found for grade 1 versus grades 2 and 3 tumors (χ2 [df, 1] = 21.6; p < 0.001); for PNETs with vascular involvement (χ2 [df, 1] = 20.8; p < 0.001); and for tumors with entropy (spatial scale filter 2) values greater than 4.65 (χ2 (df, 1) = 4.4; p = 0.037). CONCLUSION: CT texture analysis and CT features are predictive of PNET aggressiveness and can be used to identify patients at risk of early disease progression after surgical resection.


Assuntos
Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/patologia , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Meios de Contraste , Progressão da Doença , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Tumores Neuroendócrinos/cirurgia , Neoplasias Pancreáticas/cirurgia , Complicações Pós-Operatórias/diagnóstico por imagem , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
17.
AJR Am J Roentgenol ; 211(1): 52-66, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29629796

RESUMO

OBJECTIVE: The purpose of this article is to discuss the advances in CT acquisition and image postprocessing as they apply to imaging the pancreas and to conceptualize the role of radiogenomics and machine learning in pancreatic imaging. CONCLUSION: CT is the preferred imaging modality for assessment of pancreatic diseases. Recent advances in CT (dual-energy CT, CT perfusion, CT volumetry, and radiogenomics) and emerging computational algorithms (machine learning) have the potential to further increase the value of CT in pancreatic imaging.


Assuntos
Pancreatopatias/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Aprendizado de Máquina
18.
J Comput Assist Tomogr ; 42(1): 124-132, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28786906

RESUMO

OBJECTIVE: The aim of this study was to investigate the diagnostic performance of abdominopelvic computed tomography (CT) images reconstructed using filtered back projection (FBP) and iterative reconstruction (IR) algorithms in morbidly and super obese patients. MATERIALS AND METHODS: One hundred eighty-seven abdominopelvic CT examinations in portal venous phase were performed between February 2015 and February 2016 in 182 patients (mean age = 52 years, mean body mass index = 45.5). One hundred fourteen of 187 examinations were reconstructed using IR and 73 examinations were processed using FBP. Patients were further stratified based on body mass index. Sixty CT scans were reviewed by a single reader for image quality, image noise, and artifacts. Objective noise and attenuation were also determined. Size-specific dose estimate and CT dose index volume were compared and statistically analyzed. RESULTS: A diagnostic interpretation was rendered for all 187 examinations. A single-reader review of 60 cases showed greater diagnostic acceptability for IR when compared with FBP (image quality = 4.2 and 3.8 [P = 0.035], noise = 1.5 and 1.6 [P = 0.692], artifact = 1.4 and 1.5 [P = 0.759], respectively). For all examinations, the IR group had lower objective image noise (IR = 9.3 and FBP = 14.3; P < 0.001) and higher contrast-to-noise ratio (IR = 17.2 and FBP = 11.7; P < 0.001) without increase in radiation dose (size-specific dose estimate [IR = 15.1, FBP = 16.5 mGy; P = 0.045] and CT dose index volume [IR = 17.6, FBP = 18 mGy; P = 0.62]). CONCLUSIONS: In morbidly and super obese patients, diagnostic quality images could be reliably generated with minimal artifacts and noise using newer generation scanners integrated with IR without increasing radiation dose.


Assuntos
Obesidade Mórbida/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Artefatos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Software
19.
J Comput Assist Tomogr ; 42(6): 932-936, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30407239

RESUMO

PURPOSE: Our objective was to evaluate image quality (IQ) and material decomposition in patients with large body habitus undergoing portal venous phase abdominal computed tomography (CT) scans on dual-source dual-energy CT (dsDECT) scanners. METHODS: This retrospective analysis included 30 scans from consecutive patients (19 males/11 females, mean ± SD age = 55.3 ± 17.5 years, range = 27-87 years) with large body habitus (≥90 kg, mean ± SD weight = 105.4 ± 12.35, range = 91-145 kg) who underwent portal venous phase abdominal DECT examinations on dsDECT scanner between Jan 2015 and Dec 2015. Qualitative and quantitative evaluation of IQ of DECT data sets (blended, iodine, and virtual noncontrast images) was performed. The patients were categorized into 2 groups (group A, ≤104 kg; group B, >104 kg). RESULTS: The mean ± SD patient body weight in group A was 97.2 ± 4.5 kg (range = 91-104 kg) and 114.8 ± 11.7 kg (range = 104.3-145.2 kg) for patients in group B. The diagnostic acceptability of the blended images in patients > 104 kg was lower (3.6 vs 4, <3 in 4/14 vs 0/16, P = 0.03). The extension of visceral anatomy beyond DE field of view (DEFOV) was seen in 60% (28 organs in 18 patients), the most common organs being liver and spleen. The incidence of visceral organs outside DEFOV was significantly higher in patients > 104 kg (18 vs 10, P = 0.03). Outside the DEFOV, blended images demonstrated higher image noise (mean: 14.48, range = 10.09-26.83 vs mean: 9.5, range = 7.3-15.8) P < 0.001) and lower signal-to-noise ratio (mean: 4.15, range = 1.5-7.6 vs mean: 7.5, range = 4.2-9.9) P < 0.001), and material-specific information was not available in this region. Within the DEFOV, the IQ of iodine maps and virtual non-contrast images were diagnostically acceptable with diagnostic acceptability of 3 or greater in nearly all patients. A 40-cm transverse diameter cut-off provided a good predictor of extension of visceral anatomy outside the effective DEFOV. CONCLUSIONS: Dual-source DECT allows diagnostically acceptable IQ and material separation in patients with large body habitus with the major limitation of exclusion of patient anatomy and organs outside the effective dual-energy field of view.


Assuntos
Tamanho Corporal , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Iopamidol , Masculino , Pessoa de Meia-Idade , Veia Porta , Estudos Retrospectivos
20.
Proc Natl Acad Sci U S A ; 112(5): 1547-52, 2015 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-25605928

RESUMO

Addition of anti-VEGF antibody therapy to standard chemotherapies has improved survival and is an accepted standard of care for advanced non-small cell lung cancer (NSCLC). However, the mechanisms by which anti-VEGF therapy increases survival remain unclear. We evaluated dynamic CT-based vascular parameters and plasma cytokines after bevacizumab alone and after bevacizumab plus chemotherapy with carboplatin and nab-paclitaxel in advanced NSCLC patients to explore potential biomarkers of treatment response and resistance to this regimen. Thirty-six patients were enrolled in this study. The primary end point was 6-mo progression-free survival rate, which was 74% (95% CI: 57, 97). This regimen has a promising overall response rate of 36% and median time to progression of 8.5 (6.0, 38.7) mo and overall survival of 12.2 (9.6, 44.1) mo. We found that anti-VEGF therapy led to a sustained increase in plasma PlGF, a potential pharmacodynamic marker. We also found that higher levels of soluble VEGFR1 measured before starting bevacizumab with chemotherapy were associated with worse survival, supporting its potential role as biomarker of treatment resistance. Our imaging biomarker studies indicate that bevacizumab-based treatment-while reducing blood flow, volume, and permeability in the overall population-may be associated with improved survival in patients with improved tumor vasculature and blood perfusion after treatment. This hypothesis-generating study supports the notion that excessively decreasing vascular permeability and pruning/rarefaction after bevacizumab therapy may negatively impact the outcome of combination therapy in NSCLC patients. This hypothesis warrants further dose-titration studies of bevacizumab to examine the dose effect on tumor vasculature and treatment efficacy.


Assuntos
Inibidores da Angiogênese/uso terapêutico , Anticorpos Monoclonais Humanizados/uso terapêutico , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Neoplasias Pulmonares/tratamento farmacológico , Neovascularização Patológica/tratamento farmacológico , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores , Albuminas/administração & dosagem , Bevacizumab , Biomarcadores Tumorais/sangue , Carboplatina/administração & dosagem , Carcinoma Pulmonar de Células não Pequenas/irrigação sanguínea , Feminino , Humanos , Neoplasias Pulmonares/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Paclitaxel/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA