Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Radiology ; 311(2): e231921, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38805732

RESUMO

Background Many clinically relevant fractures are occult on conventional radiographs and therefore challenging to diagnose reliably. X-ray dark-field radiography is a developing method that uses x-ray scattering as an additional signal source. Purpose To investigate whether x-ray dark-field radiography enhances the depiction of radiographically occult fractures in an experimental model compared with attenuation-based radiography alone and whether the directional dependence of dark-field signal impacts observer ratings. Materials and Methods Four porcine loin ribs had nondisplaced fractures experimentally introduced. Microstructural changes were visually verified using high-spatial-resolution three-dimensional micro-CT. X-ray dark-field radiographs were obtained before and after fracture, with the before-fracture scans serving as control images. The presence of a fracture was scored by three observers using a six-point scale (6, surely; 5, very likely; 4, likely; 3, unlikely; 2, very unlikely; and 1, certainly not). Differences between scores based on attenuation radiographs alone (n = 96) and based on combined attenuation and dark-field radiographs (n = 96) were evaluated by using the DeLong method to compare areas under the receiver operating characteristic curve. The impact of the dark-field signal directional sensitivity on observer ratings was evaluated using the Wilcoxon test. The dark-field data were split into four groups (24 images per group) according to their sensitivity orientation and tested against each other. Musculoskeletal dark-field radiography was further demonstrated on human finger and foot specimens. Results The addition of dark-field radiographs was found to increase the area under the receiver operating characteristic curve to 1 compared with an area under the receiver operating characteristic curve of 0.87 (95% CI: 0.80, 0.94) using attenuation-based radiographs alone (P < .001). There were similar observer ratings for the four different dark-field sensitivity orientations (P = .16-.65 between the groups). Conclusion These results suggested that the inclusion of dark-field radiography has the potential to help enhance the detection of nondisplaced fractures compared with attenuation-based radiography alone. © RSNA, 2024 See also the editorial by Rubin in this issue.


Assuntos
Estudos de Viabilidade , Animais , Suínos , Microtomografia por Raio-X/métodos , Fraturas das Costelas/diagnóstico por imagem , Fraturas Fechadas/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos
2.
World J Urol ; 42(1): 290, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702557

RESUMO

PURPOSE: mpMRI is routinely used to stratify the risk of clinically significant prostate cancer (csPCa) in men with elevated PSA values before biopsy. This study aimed to calculate a multivariable risk model incorporating standard risk factors and mpMRI findings for predicting csPCa on subsequent prostate biopsy. METHODS: Data from 677 patients undergoing mpMRI ultrasound fusion biopsy of the prostate at the TUM University Hospital tertiary urological center between 2019 and 2023 were analyzed. Patient age at biopsy (67 (median); 33-88 (range) (years)), PSA (7.2; 0.3-439 (ng/ml)), prostate volume (45; 10-300 (ml)), PSA density (0.15; 0.01-8.4), PI-RADS (V.2.0 protocol) score of index lesion (92.2% ≥3), prior negative biopsy (12.9%), suspicious digital rectal examination (31.2%), biopsy cores taken (12; 2-22), and pathological biopsy outcome were analyzed with multivariable logistic regression for independent associations with the detection of csPCa defined as ISUP ≥ 3 (n = 212 (35.2%)) and ISUP ≥ 2 (n = 459 (67.8%) performed on 603 patients with complete information. RESULTS: Older age (OR: 1.64 for a 10-year increase; p < 0.001), higher PSA density (OR: 1.60 for a doubling; p < 0.001), higher PI-RADS score of the index lesion (OR: 2.35 for an increase of 1; p < 0.001), and a prior negative biopsy (OR: 0.43; p = 0.01) were associated with csPCa. CONCLUSION: mpMRI findings are the dominant predictor for csPCa on follow-up prostate biopsy. However, PSA density, age, and prior negative biopsy history are independent predictors. They must be considered when discussing the individual risk for csPCa following suspicious mpMRI and may help facilitate the further diagnostical approach.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Humanos , Masculino , Neoplasias da Próstata/patologia , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/sangue , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Adulto , Estudos Retrospectivos , Valor Preditivo dos Testes , Hospitais com Alto Volume de Atendimentos , Medição de Risco , Biópsia Guiada por Imagem
3.
J Med Internet Res ; 25: e50865, 2023 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-38133918

RESUMO

Exploring the generative capabilities of the multimodal GPT-4, our study uncovered significant differences between radiological assessments and automatic evaluation metrics for chest x-ray impression generation and revealed radiological bias.


Assuntos
Radiologia , Humanos , Raios X , Radiografia , Benchmarking , Percepção
4.
Eur Radiol Exp ; 8(1): 54, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38698099

RESUMO

BACKGROUND: We aimed to improve the image quality (IQ) of sparse-view computed tomography (CT) images using a U-Net for lung metastasis detection and determine the best tradeoff between number of views, IQ, and diagnostic confidence. METHODS: CT images from 41 subjects aged 62.8 ± 10.6 years (mean ± standard deviation, 23 men), 34 with lung metastasis, 7 healthy, were retrospectively selected (2016-2018) and forward projected onto 2,048-view sinograms. Six corresponding sparse-view CT data subsets at varying levels of undersampling were reconstructed from sinograms using filtered backprojection with 16, 32, 64, 128, 256, and 512 views. A dual-frame U-Net was trained and evaluated for each subsampling level on 8,658 images from 22 diseased subjects. A representative image per scan was selected from 19 subjects (12 diseased, 7 healthy) for a single-blinded multireader study. These slices, for all levels of subsampling, with and without U-Net postprocessing, were presented to three readers. IQ and diagnostic confidence were ranked using predefined scales. Subjective nodule segmentation was evaluated using sensitivity and Dice similarity coefficient (DSC); clustered Wilcoxon signed-rank test was used. RESULTS: The 64-projection sparse-view images resulted in 0.89 sensitivity and 0.81 DSC, while their counterparts, postprocessed with the U-Net, had improved metrics (0.94 sensitivity and 0.85 DSC) (p = 0.400). Fewer views led to insufficient IQ for diagnosis. For increased views, no substantial discrepancies were noted between sparse-view and postprocessed images. CONCLUSIONS: Projection views can be reduced from 2,048 to 64 while maintaining IQ and the confidence of the radiologists on a satisfactory level. RELEVANCE STATEMENT: Our reader study demonstrates the benefit of U-Net postprocessing for regular CT screenings of patients with lung metastasis to increase the IQ and diagnostic confidence while reducing the dose. KEY POINTS: • Sparse-projection-view streak artifacts reduce the quality and usability of sparse-view CT images. • U-Net-based postprocessing removes sparse-view artifacts while maintaining diagnostically accurate IQ. • Postprocessed sparse-view CTs drastically increase radiologists' confidence in diagnosing lung metastasis.


Assuntos
Neoplasias Pulmonares , Tomografia Computadorizada por Raios X , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Feminino , Estudos Retrospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso
5.
J Imaging Inform Med ; 37(2): 892-898, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38343244

RESUMO

Modern photon counting detectors allow the calculation of virtual monoenergetic or material decomposed X-ray images but are not yet used for dental panoramic radiography systems. To assess the diagnostic potential and image quality of photon counting detectors in dental panoramic radiography, ethics approval from the local ethics committee was obtained for this retrospective study. Conventional CT scans of the head and neck region were segmented into bone and soft tissue. The resulting datasets were used to calculate panoramic equivalent thickness bone and soft tissue images by forward projection, using a geometry like that of conventional panoramic radiographic systems. The panoramic equivalent thickness images were utilized to generate synthetic conventional panoramic radiographs and panoramic virtual monoenergetic radiographs at various energies. The conventional, two virtual monoenergetic images at 40 keV and 60 keV, and material-separated bone and soft tissue panoramic equivalent thickness X-ray images simulated from 17 head CTs were evaluated in a reader study involving three experienced radiologists regarding their diagnostic value and image quality. Compared to conventional panoramic radiographs, the material-separated bone panoramic equivalent thickness image exhibits a higher image quality and diagnostic value in assessing the bone structure p < . 001 and details such as teeth or root canals p < . 001 . Panoramic virtual monoenergetic radiographs do not show a significant advantage over conventional panoramic radiographs. The conducted reader study shows the potential of spectral X-ray imaging for dental panoramic imaging to improve the diagnostic value and image quality.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA