Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
J Cardiovasc Electrophysiol ; 31(7): 1793-1800, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32412155

RESUMO

INTRODUCTION: Management of subcutaneous implantable cardioverter defibrillator (S-ICD) patients with newly acquired pacing needs remains problematic. His bundle pacing (HBP) allows for cardiac pacing without significant changes in the QRS morphology. We hypothesized that HBP does not alter S-ICD sensing and functions. METHODS: Twenty consecutive patients were implanted with a HB pacemaker. Among them, 17 demonstrated successful His recruitment and were prospectively screened with the automated screening tool (AST). Results of screenings performed immediately after implant and during follow-up, during intrinsic rhythm and while pacing from all available pacing configurations, were compared using the AST score. Positive-screening tests were defined by greater than or equal to 1 positive vector. RESULTS: Among the 17 patients successfully implanted (male: 41%; mean age: 73), 13 presented an indication of ventricular pacing and four of cardiac resynchronization. Absolute AST scores during both HBP (all configurations) and intrinsic rhythm were similar (p: NS). Due to left bundle branch block correction, HBP resulted in higher number of positive vectors (AST ≥ 100). AST scores were higher during HBP when compared with right ventricular pacing (RVP) (primary vector: 272 [16; 648] vs 4.6 [0.8; 16.2]; P = .003; secondary vector: 569 [183; 1186] vs 1.5 [0.7; 8.3]; P < .0001; alternate vector: 44 [2;125] vs 4.8 [0.9; 9.3]; P = .02) and resulted in a much higher number of positive vectors. Up to 90% of the patients had a positive-screening test during HBP. This passing rate was higher when compared RVP (17%; P < .0001). CONCLUSION: HBP restores normal intrinsic conduction and minimally modifies the surface electrocardiograph and subcutaneous electrograms. When ventricular pacing is needed, HBP might represent an ideal pacing option for patients implanted with a S-ICD.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Idoso , Fascículo Atrioventricular , Estimulação Cardíaca Artificial/efeitos adversos , Eletrocardiografia , Estudos de Viabilidade , Humanos , Masculino , Resultado do Tratamento
2.
J Cardiovasc Electrophysiol ; 31(2): 494-502, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31908084

RESUMO

INTRODUCTION: We investigated whether pacing-induced electrical dyssynchrony at the time of cardiac resynchronization therapy (CRT) device implantation was associated with chronic CRT response. METHODS AND RESULTS: We included a total of 69 consecutive heart failure patients who received a CRT device. Left (LVp-RVs) and right (RVp-LVs) pacing-induced interlead delays were measured intraoperatively and used to determine if there was paced left ventricular (LV) dyssynchrony, defined as present when LVp-RVs is larger than RVp-LVs. CRT response was defined as a reduction in LV end-systolic volume ≥15%, 6 months after implantation. Paced left ventricular dyssynchrony (PLVD) was associated with ischemic cardiomyopathy (ICM) (χ2 : 8; P = .005) but not with QRS morphology nor with pacing lead positions. In a univariate analysis, PLVD (odds ratio [OR], 6.53; 95% confidence interval [CI], 2.2-18.9; P = .001), atypical left bundle branch block (LBBB) (OR, 3.3; 95% CI, 1.2-9.4; P = .022), and ICM (OR, 5.2; 95% CI, 1.6-17; P = .006) were associated with nonresponse. In a multivariate analysis, both PLVD (OR, 9.74; 95% CI, 2.8-33.9; P < .0001) and atypical LBBB (OR, 5.6; 95% CI, 1.5-20.3; P = .009) were independently associated with nonresponse. Adding PLVD to a model based on QRS morphology provided a significant and meaningful incremental value to predict LV reverse remodeling after CRT (χ2 to enter: 8; P < .005). Computer simulations corroborate these findings by showing that, while intrinsic electrical dyssynchrony is a prerequisite, the level of pacing-induced dyssynchrony modulates acute CRT response. CONCLUSION: In addition to the intrinsic electrical substrate, PLVD is strongly associated with less LV reverse remodeling, demonstrating that measuring the electrical substrate during pacing has additional value for prediction of CRT response in an already well-selected patient population.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda , Remodelação Ventricular , Adulto , Idoso , Idoso de 80 Anos ou mais , Simulação por Computador , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Estudos Prospectivos , Recuperação de Função Fisiológica , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia
3.
Cardiol Young ; 30(3): 413-417, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32066520

RESUMO

BACKGROUND AND OBJECTIVES: Young patients suffering from rhythm disorders have a negative impact in their quality of life. In recent years, ablation has become the first-line therapy for supraventricular arrhythmias in children. In the light of the current expertise and advancement in the field, we decided to evaluate the quality of life in young patients with supraventricular arrhythmias before and after a percutaneous ablation procedure. METHODS: The prospective cohort consisted of patients <18 years with structurally normal hearts and non-pre-excited supraventricular arrhythmias, who had an ablation in our centre from 2013 to 2018. The cohort was evaluated with the PedsQL™ 4.0 Generic Core Scales self-questionnaire prior to and post-ablation. RESULTS: The final cohort included 88 patients consisted of 52 males (59%), with a mean age at ablation of 12.5 ± 3.3 years. Forty-two patients (48%) had a retrograde-only accessory pathway mediating the tachycardia, 38 (43%) had atrio-ventricular nodal re-entrant tachycardia, 7 (8%) had ectopic atrial tachycardia, and 1 (1%) had atrial flutter. The main reason for an ablation was the patient's choice in 53%. There were no severe complications. Comparison between the baseline and post-ablation assessments showed that patients reported significant improvement in the scores for physical health, emotional and social functioning, as well as in the total scores. CONCLUSIONS: The present study demonstrates that the successful treatment of supraventricular arrhythmias by means of an ablation results in a significant improvement in the quality of self-reported life scores in young patients.


Assuntos
Ablação por Cateter , Qualidade de Vida , Taquicardia Supraventricular/terapia , Feixe Acessório Atrioventricular/cirurgia , Adolescente , Fibrilação Atrial/terapia , Flutter Atrial/terapia , Nó Atrioventricular/fisiopatologia , Criança , Feminino , Humanos , Masculino , Estudos Prospectivos , Taquicardia por Reentrada no Nó Atrioventricular/terapia , Taquicardia Supraventricular/fisiopatologia
4.
Pacing Clin Electrophysiol ; 40(12): 1440-1445, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28975634

RESUMO

INTRODUCTION: The aim of this study was to determine the rate of recurrent atrial flutter (AFl) after isolated cavotricuspid isthmus (CTI) ablation and to evaluate the impact of a waiting period with the search for early resumption of the CTI block on the long-term outcome. METHOD: Three hundred and nineteen consecutive patients referred for typical AFl ablation were randomly assigned to CTI ablation with continuous reevaluation of the CTI block during 30 minutes and early reablation if needed (waiting time [WT] + group, n  =  155) or to CTI ablation with no waiting period after proven bidirectional CTI block (WT - group, n  =  164). All patients were regularly followed-up. RESULT: In the WT+ group, 10 patients (6%) presented a recovery across the CTI (time to recovery: 17 ± 7') and were reablated at the end of the waiting period. After a median follow-up of 21 months, the rate of recurrent AFl was significantly higher in the WT - group as compared to the WT+ group (11.6% [19/164] vs 2.5% [4/155], respectively; P  =  0.007). However, no significant differences in the subsequent rate of AF were observed between the two groups (29% [WT -] vs 32% [WT+], P  =  0.66). During the follow-up, 28 patients from the WT - group underwent a second ablation procedure (16 AFl redo and 12 AF ablation) versus 10 patients form the WT+ group (three AFl redo and seven AF ablation). CONCLUSION: Waiting 30 minutes after CTI ablation to check for early resumption and early reablation allows for decreasing significantly the rate of recurrent atrial flutter.


Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter , Átrios do Coração/cirurgia , Idoso , Procedimentos Cirúrgicos Cardíacos/métodos , Feminino , Humanos , Masculino , Estudos Prospectivos , Fatores de Tempo , Valva Tricúspide , Veia Cava Inferior
5.
Lancet ; 386(9994): 672-9, 2015 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-26211828

RESUMO

BACKGROUND: Catheter ablation is increasingly used to manage atrial fibrillation, but arrhythmia recurrences are common. Adenosine might identify pulmonary veins at risk of reconnection by unmasking dormant conduction, and thereby guide additional ablation to improve arrhythmia-free survival. We assessed whether adenosine-guided pulmonary vein isolation could prevent arrhythmia recurrence in patients undergoing radiofrequency catheter ablation for paroxysmal atrial fibrillation. METHODS: We did this randomised trial at 18 hospitals in Australia, Europe, and North America. We enrolled patients aged older than 18 years who had had at least three symptomatic atrial fibrillation episodes in the past 6 months, and for whom treatment with an antiarrhythmic drug failed. After pulmonary vein isolation, intravenous adenosine was administered. If dormant conduction was present, patients were randomly assigned (1:1) to additional adenosine-guided ablation to abolish dormant conduction or to no further ablation. If no dormant conduction was revealed, randomly selected patients were included in a registry. Patients were masked to treatment allocation and outcomes were assessed by a masked adjudicating committee. Patients were followed up for 1 year. The primary outcome was time to symptomatic atrial tachyarrhythmia after a single procedure in the intention-to-treat population. The trial is registered with ClinicalTrials.gov, number NCT01058980. FINDINGS: Adenosine unmasked dormant pulmonary vein conduction in 284 (53%) of 534 patients. 102 (69·4%) of 147 patients with additional adenosine-guided ablation were free from symptomatic atrial tachyarrhythmia compared with 58 (42·3%) of 137 patients with no further ablation, corresponding to an absolute risk reduction of 27·1% (95% CI 15·9-38·2; p<0·0001) and a hazard ratio of 0·44 (95% CI 0·31-0·64; p<0·0001). Of 115 patients without dormant pulmonary vein conduction, 64 (55·7%) remained free from symptomatic atrial tachyarrhythmia (p=0·0191 vs dormant conduction with no further ablation). Occurrences of serious adverse events were similar in each group. One death (massive stroke) was deemed probably related to ablation in a patient included in the registry. INTERPRETATION: Adenosine testing to identify and target dormant pulmonary vein conduction during catheter ablation of atrial fibrillation is a safe and highly effective strategy to improve arrhythmia-free survival in patients with paroxysmal atrial fibrillation. This approach should be considered for incorporation into routine clinical practice. FUNDING: Canadian Institutes of Health Research, St Jude Medical, Biosense-Webster, and M Lachapelle (Montreal Heart Institute Foundation).


Assuntos
Adenosina , Antiarrítmicos , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/efeitos dos fármacos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Modelos de Riscos Proporcionais , Veias Pulmonares/cirurgia , Prevenção Secundária , Resultado do Tratamento
6.
Europace ; 18(12): 1779-1786, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27170000

RESUMO

AIMS: Despite the increased prevalence of atrial fibrillation (AF), data for the implementation of nationwide screening programmes are limited. The aim of this national screening study was to increase nationwide awareness about AF and stroke risk, to determine the prevalence of AF in Belgian general population using an ECG handheld machine and its feasibility to identify new AF cases. METHODS AND RESULTS: We analysed data obtained from 5 years of the 'Belgian Heart Rhythm Week' screening programme. All subjects were screened using a one-lead ECG handheld machine. Among 65 747 subjects screened, AF was recorded in 911, with an overall prevalence of 1.4% [95% confidence interval (CI) 1.2-1.6%]. High thrombo-embolic risk, as assessed by CHA2DS2-VASc score ≥2, was recorded in 69% of AF subjects. In subjects with high thrombo-embolic risk, only 5.4% were treated with oral anticoagulant (OAC) and 5.8% were treated with OAC and antiplatelet drugs. Among recorded AF cases, the use of the ECG handheld machine allowed identification of 603 new AF patients (1.1%, 95% CI 0.9-1.3%). Factors associated with incident AF were chronic heart failure (P < 0.001), age (P < 0.001), diabetes mellitus (P < 0.001), previous stroke (P < 0.001), vascular disease (P < 0.001), and male sex (P < 0.001). CONCLUSION: In this Belgian national screening programme, prevalence of AF was 1.4%. The use of an ECG handheld machine is feasible to identify a significant number of new AF cases, most with a high thrombo-embolic risk. Given the low OAC use recorded, greater efforts in AF detection and treatment are urgently needed to reduce the burden of stroke associated with this common arrhythmia.


Assuntos
Fibrilação Atrial/epidemiologia , Eletrocardiografia/instrumentação , Programas de Rastreamento/métodos , Acidente Vascular Cerebral/prevenção & controle , Administração Oral , Idoso , Anticoagulantes/administração & dosagem , Fibrilação Atrial/tratamento farmacológico , Bélgica/epidemiologia , Complicações do Diabetes , Feminino , Insuficiência Cardíaca/complicações , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Medição de Risco , Fatores de Risco
7.
Europace ; 17(6): 877-83, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25618742

RESUMO

AIM: After pulmonary vein isolation (PVI), dormant conduction (DC) is present in at least one vein in a substantial number of patients. The present study seeks to determine whether there is a relationship between poor contact forces (CF) and the presence of DC after PVI. METHODS AND RESULTS: This prospective, operator-blinded, non-randomized dual-centre trial enrolled 34 consecutive patients with paroxysmal atrial fibrillation who were candidates for PVI. Radiofrequency (RF) energy was delivered by using an irrigated-tip force-sensing ablation catheter (Tacticath, St Jude Medical) at pre-defined target power. The operators were blinded to the CF data at all times. A total of 1476 RF applications were delivered in 743 pre-defined PV segments. For each application, the precise location of the catheter was registered and the following data were extracted from the Tacisys unit: application duration, minimum contact force, maximum contact force, average contact force (CF), and force-time integral (FTI). Sixty minutes after PVI, spontaneous early recovery (ER) of the left atrium (LA) to PV conduction was evaluated. In the absence of ER, the presence of a DC was evaluated by using intravenous adenosine (ATP). In the 34 patients recruited (23 males; mean age: 62 ± 9 years), all PVs were successfully isolated. At the end of the 60 min waiting period, 22 patients demonstrated at least one spontaneous ER or DC under ATP. The mean CF and FTI per PV segment differed significantly among the different veins but the sites of ER and DC were evenly distributed. However, both the minimum, the first and the mean CF and FTI per PV segment were significantly lower in the PV segments presenting either ER or DC as compared with those without ER or DC (mean CF: 4.9 ± 4.8 vs. 12.2 ± 1.65 g and mean FTI: 297 ± 291 vs. 860 ± 81 g s, P < 0.001 for both). Using multivariate analysis, both the mean CF and the FTI per lesion remained significantly associated with the risk of ER or DC. Moreover, a CF < 5 g per PV segment predicted ER+ and DC+ with a sensitivity of 71% and specificity of 82%. In contrast, ER and DC were very unlikely if RF application was performed with a mean CF > 10 g (negative predictive value: 98.7%). CONCLUSION: Both a low CF and a low FTI are associated with the ER of the PVI and DC after PVI.


Assuntos
Adenosina , Antiarrítmicos , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Adulto , Idoso , Estudos de Coortes , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Método Simples-Cego , Resultado do Tratamento
8.
Emerg Med J ; 32(6): 481-5, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25082717

RESUMO

AIM: To determine the effect of a new automated external defibrillator (AED) system connected by General Packet Radio Service (GPRS) to an external call centre in assisting novices in a sudden cardiac arrest situation. METHOD: Prospective, interventional study. Layperson volunteers were first asked to complete a survey about their knowledge and ability to give cardiopulmonary resuscitation (CPR) and use an AED. A simulated cardiac arrest scenario using a CPR manikin was then presented to volunteers. A telephone and semi-AED were available in the same room. The AED was linked to a call centre, which provided real-time information to 'bystanders' and emergency services via GPRS/GPS technology. The scene was videotaped to avoid any interaction with examiners. A standardised check list was used to record correct actions. RESULTS: 85 volunteers completed questionnaires and were recorded. Mean age was 44±16, and 49% were male; 38 (45%) had prior CPR training or felt comfortable intervening in a sudden cardiac arrest victim; 40% felt they could deliver a shock using an AED. During the scenarios, 56 (66%) of the participants used the AED and 53 (62%) successfully delivered an electrical shock. Mean time to defibrillation was 2 min 29 s. Only 24 (28%) participants dialled the correct emergency response number (112); the live-assisted GPRS AED allowed alerted emergency services in 38 other cases. CPR was initiated in 63 (74%) cases, 26 (31%) times without prompting and 37 (44%) times after prompting by the AED. CONCLUSIONS: Although knowledge of the general population appears to be inadequate with regard to AED locations and recognition, live-assisted devices with GPS-location may improve emergency care.


Assuntos
Desfibriladores , Sistemas de Comunicação entre Serviços de Emergência , Sistemas de Informação Geográfica , Parada Cardíaca/diagnóstico , Parada Cardíaca/terapia , Gravação em Vídeo , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Tomada de Decisões , Feminino , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Masculino , Manequins , Pessoa de Meia-Idade , Estudos Prospectivos , Autoimagem , Adulto Jovem
9.
Europace ; 16(8): 1125-30, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24599938

RESUMO

AIMS: Atrial fibrillation (AF) patients treated according to a rate-control strategy seem to have excellent outcomes as long as their ventricular response is kept low. However, the stringency of the rate control to adopt with pharmacologic agents is not clearly defined. In particular, the clinical importance of preserving a heart rate (HR) reserve (HRR) during exercise has not yet been investigated. METHODS AND RESULTS: We prospectively analysed the HR response profiles during exercise of 202 patients with permanent AF for whom a strict rate-control strategy was the preferred treatment option. Patients were asked to perform an exercise test on a cycle ergometer until exhaustion. The HRR was defined as the difference between the HR at peak exercise and the resting HR before exercise, divided by the resting HR. Patients were followed-up for at least 24 months or until death or hospitalization for heart failure. The mean resting HR was 80 ± 16 b.p.m. After a median follow-up period of 3 ± 1 years, 31 patients (15.3%) of our initial population (80% male, age 72 ± 12 years) presented either a hospitalization for heart failure (n = 13, 6.4%) or a death (n = 18, 8.9%). Using a univariate analysis, we found that these events correlated with a lower exercise capacity [hazard ratio, HR 0.98, 95% confidence interval, CI (0.96; 0.99), P < 0.001] and a lower HRR [HR 0.30, 95% CI (0.15; 0.60), P < 0.001]. Using a multivariate analysis, both the exercise capacity [HR 0.98, 95% CI (0.97; 0.99), P = 0.008] and the HRR [HR 0.42, 95% CI (0.20-0.87), P = 0.02] remained significantly associated with the outcome. In particular, 4-year survival free from hospitalization for heart failure was better in patients with a preserved HRR (HRR >40%, P < 0.001). No correlation was found between the treatment category (i.e. beta-blockers, calcium channel antagonist, and digoxin) and the HRR. CONCLUSION: An impaired HRR in patients with permanent AF treated according to a strict rate-control strategy is associated with an increased risk of hospitalization for heart failure.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Sistema de Condução Cardíaco/efeitos dos fármacos , Frequência Cardíaca/efeitos dos fármacos , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Fibrilação Atrial/fisiopatologia , Ciclismo , Distribuição de Qui-Quadrado , Intervalo Livre de Doença , Teste de Esforço , Tolerância ao Exercício , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Hospitalização , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
10.
JACC Basic Transl Sci ; 9(4): 459-471, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38680960

RESUMO

The role of atrial metabolism alterations for initiation and atrial fibrillation (AF) persistence remains poorly understood. Therefore, we evaluated left atrial glucose metabolism by nicotinic acid derivative stimulated 18-fluorodeoxyglucose positron emission tomography in 36 patients with persistent AF undergoing catheter ablation before and 3 months after return to sinus rhythm and compared values against healthy controls. Under identical hemodynamics and metabolic conditions, and although left ventricular FDG uptake remained unchanged, patients in persistent AF presented significantly higher total left atrial and left atrial appendage uptake, which decreased significantly after return to sinus rhythm, despite improvement of passive and active atrial contractile function. These findings support a role of altered glucose metabolism and metabolic wasting underlying the pathophysiology of persistent AF.

11.
Acta Cardiol ; 68(2): 139-43, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23705555

RESUMO

BACKGROUND: The number of fitness centres has increased in Western countries, some proposing specific training programmes (cardiac patients, weight loss or seniors).There is a real risk of cardiovascular events for individuals without cardiovascular evaluation. Fitness centres could represent a place at particularly high risk for sudden cardiac arrest (SCA). OBJECTIVE AND METHODS: In this observational study, we evaluated the number of fitness centres with automatic external defibrillators (AEDs) throughout the French-speaking part of Belgium, their geographic localization, the number of attendees, and the number of SCA reported. Details of AED and SCA were obtained by telephone survey. RESUITS: A total of 51 centres were surveyed. Only 5 (9.8%) had an AED and 68.8% (35/51) of centres had > 1 staff members specifically trained in CPR. Since the opening of these facilities, 5 SCA were reported from 3 centres (5.9%). Only 2 fitness centres had an AED present at the time of the SCA.Two SCA were unwitnessed, and for another 2 victims AED was used without success. Well-conducted CPR (no AED available) resulted in the only survivor of SCA. CONCLUSION: The rate of SCA in fitness centres in French-speaking Belgium is comparable to that reported in other countries. AED were available in less than 10% of centres and no CPR trained staff was available in almost one third of the centres.


Assuntos
Desfibriladores/estatística & dados numéricos , Academias de Ginástica/estatística & dados numéricos , Arritmias Cardíacas/prevenção & controle , Bélgica , Morte Súbita Cardíaca/prevenção & controle , Humanos , Estudos Retrospectivos
12.
J Cardiovasc Electrophysiol ; 23(11): 1201-6, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22734452

RESUMO

INTRODUCTION: Early recovery of conduction (ER) after cavotricuspid isthmus (CTI) ablation for typical atrial flutter (AFl) occurs in approximately 10% of the patients. If not recognized, ER might lead to AFl recurrences. In this study, we hypothesized that intravenous adenosine (iADO) can be used to predict ER in the CTI immediately after RF ablation and distinguish functional block from the complete destruction of the CTI myocardium. METHODS: We prospectively included 68 consecutive patients (age: 65 ± 14 years; male: 78%) referred in our centers for AFl ablation. Immediately after bidirectional isthmus block validation, a bolus of iADO was given during continuous pacing from the proximal coronary sinus. Patients with functional block revealed under iADO (iADO+) and those without (iADO-) were subsequently observed for a 30-minute waiting period (ER-) or until sustained recovery of the conduction through the CTI (ER+). RESULTS: Seven patients presented a persistent recovery (ER+, 10.3%, mean time to recovery: 14 ± 9 minutes). None of them presented even a transient resumption of conduction under iADO (iADO+: 0). With univariate analysis, we identified a heavy patient weight (>95 kg) as a predictor of ER (sensitivity: 71%). CONCLUSIONS: Adenosine does not predict early recovery in the CTI after linear ablation for atrial flutter. We found that a patient weight over 95 kg predicted early recovery of conduction through the CTI with a sensitivity of 71%.


Assuntos
Adenosina/administração & dosagem , Flutter Atrial/cirurgia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Valva Tricúspide/cirurgia , Idoso , Flutter Atrial/diagnóstico , Flutter Atrial/fisiopatologia , Peso Corporal , Estimulação Cardíaca Artificial , Ablação por Cateter/efeitos adversos , Distribuição de Qui-Quadrado , Feminino , Humanos , Infusões Intravenosas , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Recidiva , Sensibilidade e Especificidade , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide/fisiopatologia
13.
Europace ; 14(4): 496-501, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22071380

RESUMO

AIMS: This prospective non-randomized single-centre registry compared clinical outcome, pacing parameters, and long-term survival in patients receiving VDD or DDD pacemaker (PMs) for symptomatic atrioventricular (AV) block. METHODS AND RESULTS: Single-lead VDD (n= 166) and DDD (n= 254) PMs were implanted in 420 successive patients with isolated AV block between January 2001 and December 2009. At the end of the follow-up period [median 25 (1-141) months], there was no difference in the incidence of atrial fibrillation [11.2% in the VDD group; 11.4% in the DDD group (P= 0.95)], myocardial infarction [31.1% in the VDD group; 25.2% in the DDD group (P= 0.20)], or dilated cardiomyopathy [9.9% in the VDD group; 8.9% in the DDD group (P= 0.74)]. At last follow-up, 65.9% of the VDD PMs and 89.3% of the DDD PMs were still programmed in their original mode with good atrial sensing. Due to permanent atrial fibrillation, 7.9% patients out of the VDD group had been switched to VVIR mode and 8.7% patients out of the DDD group to VVIR or DDIR mode. The P-wave amplitude was poor (sensed P-wave <0.5 mV) in 19.1% of the VDD PM and 1.6% of the DDD PM (P< 0.001) and 7.1% of the VDD patients and 0.4% of the DDD patients had been switched to VVIR pacing mode due to P-wave undersensing and AV dissociation (P= 0.003). Symptomatic atrial undersensing requiring upgrading was similar in both groups. The overall survival, adjusted for age, was not significantly different in the VDD and the DDD group (log rank: 0.26). Moreover, Cox survival analysis excluded the pacing mode as a significant predictor of mortality [hazard ratio (HR) = 0.79, confidence interval (CI) (0.46-1.35), P= 0.39]. CONCLUSION: Comparing VDD and DDD pacing, a significantly larger number of VDD-paced patients developed poor atrial signal detection without clinical impact. However, atrial under sensing did not influence the incidence of atrial fibrillation, myocardial infarction, dilated cardiomyopathy, or mortality.


Assuntos
Bloqueio Atrioventricular/mortalidade , Bloqueio Atrioventricular/prevenção & controle , Estimulação Cardíaca Artificial/mortalidade , Estimulação Cardíaca Artificial/métodos , Idoso , Bélgica/epidemiologia , Feminino , Seguimentos , Humanos , Masculino , Prevalência , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Análise de Sobrevida , Taxa de Sobrevida , Resultado do Tratamento
15.
Acta Cardiol ; 67(4): 487-9, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22998008

RESUMO

Lead implantation in young adults with congenital heart disease is often problematic due to the reduction in the number of surgical access routes and consequent scar tissue formation related to previous surgery. In such a situation, anatomic and electromagnetic voltage mapping of the heart may be useful to find the optimal implantation site for sensing and pacing activities.


Assuntos
Arritmias Cardíacas/terapia , Mapeamento Potencial de Superfície Corporal , Marca-Passo Artificial , Adulto , Estimulação Cardíaca Artificial , Eletrodos Implantados , Técnicas Eletrofisiológicas Cardíacas , Feminino , Átrios do Coração/fisiopatologia , Cardiopatias Congênitas , Ventrículos do Coração/fisiopatologia , Humanos , Imageamento Tridimensional
16.
Front Cardiovasc Med ; 9: 856796, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35694674

RESUMO

Background: Non-invasive evaluation of left atrial structural and functional remodeling should be considered in all patients with persistent atrial fibrillation (AF) to optimal management. Speckle tracking echocardiography (STE) has been shown to predict AF recurrence after catheter ablation; however in most studies, patients had paroxysmal AF, and STE was performed while patients were in sinus rhythm. Aim: The aim of this study was to evaluate the ability of STE parameters acquired during persistent AF to assess atrial fibrosis measured by low voltage area, and to predict maintenance of sinus rhythm of catheter ablation. Methods: A total of 94 patients (69 men, 65 ± 9 years) with persistent AF prospectively underwent measurement of Global Peak Atrial Longitudinal Strain (GPALS), indexed LA Volume (LAVI), E/e' ratio, and LA stiffness index (the ratio of E/e' to GPALS) by STE prior to catheter ablation, while in AF. Low-voltage area (LVA) was assessed by electro-anatomical mapping and categorized into absent, moderate (>0 to <15%), and high (≥15%) atrial extent. AF recurrence was evaluated after 3 months of blanking. Results: Multivariable regression showed that LAVI, GPALS, and LA stiffness independently predicted LVA extent after correcting for age, glomerular filtration rate, and CHA2DS2-VASc score. Of all the parameters, LA stiffness index had the highest diagnostic accuracy (AUC 0.85), allowing using a cut-off value ≥0.7 to predict moderate or high LVA with 88% sensitivity and 47% specificity, respectively. In multivariable Cox analysis, both GPALS and LA stiffness were able to significantly improve the c statistic to predict AF recurrence (n = 40 over 9 months FU) over CHARGE-AF (p < 0.001 for GPALS and p = 0.01 for LA stiffness) or CHA2DS2-VASc score (p < 0.001 for GPALS and p = 0.02 for LA stiffness). GPALS and LA stiffness also improved the net reclassification index (NRI) over the CHARGE-AF index (NRI 0.67, 95% CI [0.33-1.13] for GPALS and NRI 0.73, 95% CI [0.12-0.91] for LA stiffness, respectively), and over the CHA2DS2-VASc score (NRI 0.43, 95% CI [-0.14 to 0.69] for GPALS and NRI 0.52, 95% CI [0.10-0.84], respectively) for LA stiffness to predict AF recurrence at 9 months. Conclusion: STE parameters acquired during AF allow prediction of LVA extent and AF recurrence in patients with persistent AF undergoing catheter ablation. Therefore, STE could be a valuable approach to select candidates for catheter ablation.

17.
Acta Cardiol ; 66(5): 653-6, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22032063

RESUMO

A 67-year-old woman with paroxysmal atrial fibrillation (AF), not a candidate for anticoagulant therapy, underwent a combined procedure of pulmonary vein isolation (PVI) and occlusion of the left atrial appendage (LAA) with the Amplatzer cardiac plug prosthesis (AGA Medical Corporation, Plymouth, U.S.A.). After PVI, implantation of the Amplatzer cardiac plug was performed under transoesophageal echocardiography guidance after a complete evaluation of the LAA obtained by different imaging techniques. One month later, multidetector computed tomography and transoesophageal echocardiography confirmed proper position of the Amplatzer cardiac plug not interfering with the surrounding structures and the absence of complications resulting from either PVI or LAA closure.


Assuntos
Angioplastia Coronária com Balão , Apêndice Atrial , Fibrilação Atrial/terapia , Implantação de Prótese/instrumentação , Veias Pulmonares , Dispositivo para Oclusão Septal , Idoso , Angioplastia Coronária com Balão/métodos , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Angiografia Coronária , Ecocardiografia Transesofagiana , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Veias Pulmonares/diagnóstico por imagem , Resultado do Tratamento
18.
Can J Cardiol ; 36(12): 1965-1974, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33157186

RESUMO

BACKGROUND: Pulmonary vein (PV) stenosis is a complication of atrial fibrillation (AF) ablation. The incidence of PV stenosis after routine post-ablation imaging remains unclear and is limited to single-centre studies. Our objective was to determine the incidence and predictors of PV stenosis following circumferential radiofrequency ablation in the multicentre Adenosine Following Pulmonary Vein Isolation to Target Dormant Conduction Elimination (ADVICE) trial. METHODS: Patients with symptomatic AF underwent circumferential radiofrequency ablation in one of 13 trial centres. Computed tomographic (CTA) or magnetic resonance (MRA) angiography was performed before ablation and 90 days after ablation. Two blinded reviewers measured PV diameters and areas. PVs with stenosis were classified as severe (> 70%), moderate (50%-70%), or mild (< 50%). Predictors of PV stenosis were identified by means of multivariable logistic regression. RESULTS: A total of 197 patients (median age 59.5 years, 29.4% women) were included in this substudy. PV stenosis was identified in 41 patients (20.8%) and 47 (8.2%) of 573 ablated PVs. PV stenosis was classified as mild in 42 PVs (7.3%) and moderate in 5 PVs (0.9%). No PVs had severe stenosis. Both cross-sectional area and diameter yielded similar classifications for severity of PV stenosis. Diabetes was associated with a statistically significant increased risk of PV stenosis (OR 4.91, 95% CI 1.45-16.66). CONCLUSIONS: In the first systematic multicentre evaluation of post-ablation PV stenosis, no patient acquired severe PV stenosis. Although the results are encouraging for the safety of AF ablation, 20.8% of patients had mild or moderate PV stenosis, in which the long-term effects are unknown.


Assuntos
Fibrilação Atrial , Ablação por Cateter/efeitos adversos , Angiografia por Ressonância Magnética , Complicações Pós-Operatórias , Veias Pulmonares , Estenose de Veia Pulmonar , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Canadá/epidemiologia , Ablação por Cateter/métodos , Angiografia por Tomografia Computadorizada/métodos , Angiografia por Tomografia Computadorizada/estatística & dados numéricos , Feminino , Humanos , Incidência , Angiografia por Ressonância Magnética/métodos , Angiografia por Ressonância Magnética/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Avaliação de Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/fisiopatologia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/patologia , Veias Pulmonares/cirurgia , Fatores de Risco , Índice de Gravidade de Doença , Estenose de Veia Pulmonar/diagnóstico , Estenose de Veia Pulmonar/epidemiologia , Estenose de Veia Pulmonar/etiologia , Estenose de Veia Pulmonar/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA