Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Clin Microbiol ; 58(10)2020 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-32665420

RESUMO

Coronavirus disease (COVID) serological tests are essential to determine the overall seroprevalence of a population and to facilitate exposure estimates within that population. We performed a head-to-head assessment of enzyme immunoassays (EIAs) and point-of-care lateral flow assays (POCTs) to detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies. Demographics, symptoms, comorbidities, treatment, and mortality of patients whose sera were used were also reviewed. Six EIAs (Abbott, Affinity, Bio-Rad, DiaSorin, Euroimmun, and Roche) and six POCTs (BTNX, Biolidics, Deep Blue, Genrui, Getein BioTech, and Innovita) were evaluated for the detection of SARS-CoV-2 antibodies in known COVID-19-infected individuals. Sensitivity of EIAs ranged from 50 to 100%, with only four assays having overall sensitivities of >95% after 21 days after symptom onset. Notably, cross-reactivity with other respiratory viruses (parainfluenza virus [PIV-4] [n = 5], human metapneumovirus [hMPV] [n = 3], rhinovirus/enterovirus [n = 1], CoV-229E [n = 2], CoV-NL63 [n = 2], and CoV-OC43 [n = 2]) was observed; however, overall specificity of EIAs was good (92 to 100%; all but one assay had specificity above 95%). POCTs were 0 to 100% sensitive >21 days after onset, with specificity ranging from 96 to 100%. However, many POCTs had faint banding and were often difficult to interpret. Serology assays can detect SARS-CoV-2 antibodies as early as 10 days after symptom onset. Serology assays vary in their sensitivity based on the marker (IgA/IgM versus IgG versus total) and by manufacturer; however, overall only 4 EIAs and 4 POCTs had sensitivities of >95% >21 days after symptom onset. Cross-reactivity with other seasonal coronaviruses is of concern. Serology assays should not be used for the diagnosis of acute infection but rather in carefully designed serosurveys to facilitate understanding of seroprevalence in a population and to identify previous exposure to SARS-CoV-2.


Assuntos
Anticorpos Antivirais/sangue , Betacoronavirus/isolamento & purificação , Adulto , Idoso , Idoso de 80 Anos ou mais , Betacoronavirus/imunologia , Teste para COVID-19 , Técnicas de Laboratório Clínico , Infecções por Coronavirus/sangue , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/epidemiologia , Reações Cruzadas , Feminino , Humanos , Técnicas Imunoenzimáticas , Masculino , Pessoa de Meia-Idade , Sistemas Automatizados de Assistência Junto ao Leito , SARS-CoV-2 , Sensibilidade e Especificidade , Estudos Soroepidemiológicos , Testes Sorológicos , Fatores de Tempo
2.
Pediatr Blood Cancer ; 63(4): 740-2, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26806811

RESUMO

The classic principles put forth by Wilson and Jungner are often applied to determine the suitability of a condition for universal newborn screening. The three cases described here portray the harmful effects of vitamin B12 deficiency in infancy. The challenges and opportunities of early recognition and treatment are highlighted. Screening newborns would allow early detection and prevention of severe neurological damage in vitamin B12 -deficient infants and enable diagnosis of unrecognized maternal pernicious anemia in asymptomatic mothers. However, lack of standardized methodology and screening cutoffs present challenges to the use of current tandem mass spectrometry technologies for screening.


Assuntos
Triagem Neonatal , Deficiência de Vitamina B 12/diagnóstico , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Deficiência de Vitamina B 12/fisiopatologia
3.
Ther Drug Monit ; 34(3): 306-11, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22569352

RESUMO

BACKGROUND: Paraproteins, immunoglobulins (Igs), which are elevated in various autoimmune disorders, are known to interfere with various laboratory immunoassays, including vancomycin (VANC). Rheumatoid factor (RF), a known immunoassay interferant, may cause falsely elevated results. OBJECTIVES: The aims of this study were to (1) evaluate the effect of 3 paraproteins (IgA, IgG, and IgM) on 4 commercial VANC immunoassays [fluorescence polarization immunoassay; enzyme multiplied immunoassay; 2 particle-enhanced turbidimetric inhibition immunoassays]; (2) determine the concentration at which the effect is obtained, and (3) examine the influence of RF on the VANC methods. METHOD: Serum and plasma pools from patients prescribed VANC and a spiked VANC pool (20 mg/L) were each mixed 1:1 with individual patient specimens containing IgA (6-63 g/L), IgG (6-54 g/L), IgM (3-30 g/L) (n = 4 for each Ig), and a patient RF pool (196 IU/L). The mixtures (n = 39) were split and distributed for VANC analysis. RESULTS: IgA and IgG in serum and plasma did not affect any of the VANC immunoassays. RF added to plasma specimens did not interfere, but in serum, elevated VAN results were observed. IgM did not affect the fluorescence polarization immunoassay and enzyme multiplied immunoassay methods but did attenuate VANC concentrations by both particle-enhanced turbidimetric inhibition immunoassays (Siemens, Beckman Coulter), with a more pronounced effect on the latter, producing concentrations >20% lower than expected in the patient serum and spiked plasma pools. The effect was progressively negative at effective IgM concentrations of 10 and 15 mg/L. CONCLUSIONS: This phenomenon is a major analytical and clinical issue that must be communicated to health care professionals caring for patients receiving VANC, so optimal therapy is achieved.


Assuntos
Antibacterianos/sangue , Pessoal de Laboratório Médico/normas , Paraproteínas/fisiologia , Fator Reumatoide/fisiologia , Vancomicina/sangue , Pessoal de Saúde/normas , Humanos , Imunoensaio/métodos , Imunoensaio/normas , Imunoglobulina A/fisiologia , Imunoglobulina G/fisiologia , Imunoglobulina M/fisiologia , Vancomicina/normas
4.
Artigo em Inglês | MEDLINE | ID: mdl-19423750

RESUMO

Ganglioside GD3 is a glycosphingolipid found in colostrum, developing tissues, and tumors and is known to regulate cell growth, differentiation, apoptosis, and inflammation. Feeding a GD3-enriched diet to rats increases GD3 in intestinal lipid rafts and blood. The mechanism, efficiency, and fate of ganglioside absorption by human enterocytes have not been investigated. A model to study GD3 uptake by human intestinal cells was developed to test the hypothesis that enterocyte GD3 uptake is time and concentration dependent, with uptake efficiency and fate influenced by route of delivery. Caco-2 cells were exposed to GD3 on the apical or basolateral membrane (BLM) side for 6, 24, and 48 h. GD3 uptake, retention, transfer, and metabolism was determined. GD3 uptake across the apical and BLM was time and concentration dependent and reached a plateau. GD3 uptake across the BLM was more efficient than apical delivery. Apical GD3 was metabolized with some cell retention and transfer, whereas basolateral GD3 was mostly metabolized. This study demonstrates efficient GD3 uptake by enterocytes and suggests that the route of delivery influences ganglioside uptake and fate.


Assuntos
Polaridade Celular , Enterócitos/metabolismo , Gangliosídeos/metabolismo , Transporte Biológico , Biotransformação , Células CACO-2 , Sobrevivência Celular/efeitos dos fármacos , Relação Dose-Resposta a Droga , Enterócitos/efeitos dos fármacos , Enterócitos/patologia , Gangliosídeos/toxicidade , Humanos , Cinética , Necrose
5.
Br J Nutr ; 101(5): 694-700, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18713482

RESUMO

Gangliosides are glycosphingolipids found in cell membranes and human milk with important roles in cell proliferation, differentiation, growth, adhesion, migration, signalling and apoptosis. Similar changes in ganglioside composition occur during embryonic development, lactation and cancer cell differentiation. It is not known, however, whether ganglioside compositional changes that occur in differentiating colon cancer cells reflect changes that occur during intestinal development. The Caco-2 cell line is commonly used to study physiological and pathophysiological processes in the small intestine and colon. Therefore, to examine this question, undifferentiated and differentiated Caco-2 cells were grown and total lipid was extracted from cell supernatant fractions using the Folch method. The upper aqueous phase containing gangliosides was collected and purified. Total gangliosides were measured as ganglioside-bound N-acetyl neuraminic acid, while individual ganglioside content was quantified via a colorimetric assay for sialic acid and scanning densitometry. The total ganglioside content of differentiated Caco-2 cells was 2.5 times higher compared with undifferentiated cells. Differentiated Caco-2 cells had significantly more (N-acetylneuraminyl) 2-galactosylglucosyl ceramide (GD3) and polar gangliosides, and a lower N-acetylneuraminylgalactosylglucosylceramide (GM3):GD3 ratio than undifferentiated cells. The present study demonstrates that the total ganglioside content and individual ganglioside composition of differentiated Caco-2 cells are similar to those of human colostrum and neonatal rat intestine. Differentiated Caco-2 cells may therefore be an alternative model for studying physiological and pathological processes in the small intestine and colon, and may help to elucidate possible functions for specific gangliosides in development and differentiation. Further research using more sensitive techniques of ganglioside analysis is needed to confirm these findings.


Assuntos
Células CACO-2/metabolismo , Gangliosídeos/metabolismo , Fosfatase Alcalina , Animais , Animais Recém-Nascidos , Antígenos de Neoplasias/metabolismo , Células CACO-2/patologia , Diferenciação Celular/fisiologia , Polaridade Celular/fisiologia , Colostro/química , Proteínas Ligadas por GPI , Humanos , Mucosa Intestinal/patologia , Mucosa Intestinal/fisiopatologia , Intestinos/química , Modelos Biológicos , Ratos
6.
J Pediatr Gastroenterol Nutr ; 49(4): 382-92, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19745762

RESUMO

OBJECTIVES: Necrotizing enterocolitis (NEC) has high morbidity in premature infants. Hypoxia-ischemia, infection, and enteral feeding are risk factors associated with NEC, whereas feeding human milk is protective. Vasoactive and inflammatory mediators in NEC remain elusive. Gangliosides are found in human milk and enterocyte membranes. An infant bowel model of NEC was developed to test the hypothesis that gangliosides modulate the inflammatory response to infection and hypoxia. PATIENTS AND METHODS: Viable, noninflamed bowel was obtained from 9 infants between 26 and 40 weeks' gestational age. Infant bowel was treated in culture with Escherichia coli lipopolysaccharide (LPS) and hypoxia in the presence or absence of preexposure to gangliosides. Bowel necrosis and production of nitric oxide, endothelin-1, serotonin, eicosanoids, hydrogen peroxide, and proinflammatory cytokines were measured. RESULTS: Ganglioside preexposure reduced bowel necrosis and endothelin-1 production in response to LPS. Gangliosides suppressed infant bowel production of nitric oxide, leukotriene B4, prostaglandin E2, hydrogen peroxide, interleukin-1beta, interleukin-6, and interleukin-8 in response to LPS exposure and hypoxia. CONCLUSIONS: A bowel protective effect of gangliosides is indicated by modulation of vasoactive mediators and proinflammatory signal suppression.


Assuntos
Anti-Inflamatórios/uso terapêutico , Colo/efeitos dos fármacos , Enterocolite Necrosante/tratamento farmacológico , Gangliosídeos/uso terapêutico , Mediadores da Inflamação/metabolismo , Inflamação/prevenção & controle , Animais , Anti-Inflamatórios/farmacologia , Colo/patologia , Endotelina-1/biossíntese , Enterocolite Necrosante/microbiologia , Escherichia coli , Gangliosídeos/farmacologia , Humanos , Hipóxia/tratamento farmacológico , Técnicas In Vitro , Recém-Nascido , Lipopolissacarídeos , Leite/química , Necrose/prevenção & controle
7.
Int J Neonatal Screen ; 5(4): 37, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33072996

RESUMO

Newborn screening (NBS) in Alberta is delivered by a number of government and health service entities who work together to provide newborn screening to infants born in Alberta, the Northwest Territories, and the Kitikmeot region of the Nunavut territory. The Alberta panel screens for 21 disorders (16 metabolic, two endocrine, cystic fibrosis, severe combined immunodeficiency, and sickle cell disease). NBS is a standard of care, but is not mandatory. NBS performance is monitored by the Alberta Newborn Metabolic Screening (NMS) Program and NMS Laboratory, who strive for continuous quality improvement. Performance analysis found that over 99% of registered infants in Alberta received a newborn screen and over 98% of these infants received a screen result within 10 days of age.

8.
World J Gastroenterol ; 14(14): 2142-61, 2008 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-18407587

RESUMO

Necrotizing enterocolitis is an inflammatory bowel disease of neonates with significant morbidity and mortality in preterm infants. Due to the multifactorial nature of the disease and limitations in disease models, early diagnosis remains challenging and the pathogenesis elusive. Although preterm birth, hypoxic-ischemic events, formula feeding, and abnormal bacteria colonization are established risk factors, the role of genetics and vasoactive/inflammatory mediators is unclear. Consequently, treatments do not target the specific underlying disease processes and are symptomatic and surgically invasive. Breast-feeding is the most effective preventative measure. Recent advances in the prevention of necrotizing enterocolitis have focused on bioactive nutrients and trophic factors in human milk. Development of new disease models including the aspect of prematurity that consistently predisposes neonates to the disease with multiple risk factors will improve our understanding of the pathogenesis and lead to discovery of innovative therapeutics.


Assuntos
Enterocolite Necrosante/diagnóstico , Enterocolite Necrosante/terapia , Gastroenterologia/métodos , Eicosanoides/metabolismo , Predisposição Genética para Doença , Humanos , Hipóxia , Recém-Nascido , Inflamação , Intestinos/imunologia , Isquemia/patologia , Leite Humano/metabolismo , Espécies Reativas de Oxigênio , Fatores de Risco , Transdução de Sinais , Resultado do Tratamento
9.
JPEN J Parenter Enteral Nutr ; 41(4): 657-666, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-26673692

RESUMO

BACKGROUND: Preclinical studies reveal associations between intestinal ganglioside content and inflammatory bowel disease (IBD). Since a low level of ganglioside is associated with higher production of proinflammatory signals in the intestine, it is important to determine safety and bioavailability of dietary ganglioside for application as a potential therapeutic agent. MATERIALS AND METHODS: Healthy volunteers (HVs; n = 18) completed an 8-week supplementation study to demonstrate safety and bioavailabity of ganglioside consumption. HVs were randomized to consume a milk fat fraction containing 43 mg/d ganglioside or placebo, and patients with IBD (n = 5) consumed ganglioside supplement in a small pilot study. Plasma gangliosides were characterized using reverse-phase liquid chromatography-QQQ mass spectrometry. Intestinal permeability was assessed by oral lactulose/mannitol, and quality of life was assessed by quality of life in the IBD questionnaire. RESULTS: There were no adverse events associated with dietary ganglioside intake. Ganglioside consumption increased ( P < .05) plasma content of total GD3 by 35% over 8 weeks. HVs consuming ganglioside exhibited a 19% decrease in intestinal permeability ( P = .04). Consumption of ganglioside was associated with a 39% increase ( P < .01) in emotional health and a 36% improvement ( P < .02) in systemic symptoms in patients with IBD. CONCLUSION: Impaired intestinal integrity characteristic of IBD results in increased permeability to bacterial antigens and decreased nutrient absorption. Intestinal integrity may be improved by dietary treatment with specific species of ganglioside. Ganglioside is a safe, bioavailable dietary compound that can be consumed to potentially improve quality of life in patients with IBD and treat other disorders involving altered ganglioside metabolism. This study was registered at clinicaltrials.gov as NCT02139709.


Assuntos
Gangliosídeos/administração & dosagem , Gangliosídeos/sangue , Adulto , Biomarcadores/sangue , Citocinas/sangue , Relação Dose-Resposta a Droga , Método Duplo-Cego , Feminino , Glicolipídeos/administração & dosagem , Glicolipídeos/sangue , Glicoproteínas/administração & dosagem , Glicoproteínas/sangue , Humanos , Doenças Inflamatórias Intestinais/sangue , Doenças Inflamatórias Intestinais/tratamento farmacológico , Mucosa Intestinal/metabolismo , Intestinos/efeitos dos fármacos , Gotículas Lipídicas , Masculino , Permeabilidade , Projetos Piloto , Qualidade de Vida , Inquéritos e Questionários
10.
Clin Biochem ; 49(18): 1387-1389, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26994557

RESUMO

OBJECTIVE: To determine the optimum storage temperature for serum allergen specific IgE antibodies (sIgE) to common food and inhalant allergens. METHODS: Patient sera with sIgE concentrations ≥0.7kIUA/l were pooled accordingly: pool 1-peanut and hazelnut, pool 2-egg white, cow's milk and cod fish, pool 3-soy, wheat and shrimp and pool 4-dust mite Dermatophagoides farinae, dog dander, cat dander, Timothy grass pollen, and silver birch pollen. Aliquots stored frozen, refrigerated and at room temperature were tested in duplicate (Phadia ImmunoCAP® 250) over two weeks. The relative difference was calculated for each sIgE as a percentage of the initial value and compared to the analytical reference change value. RESULTS: Minimal effects on specimen stability were noted for all sIgE analyzed under the three storage conditions tested in this study. All changes observed in sIgE concentrations were related to the assay variability and not to sample deterioration. CONCLUSION: Serum allergen specific IgE concentrations are stable at all temperatures studied for up to 17days.


Assuntos
Alérgenos/imunologia , Hipersensibilidade Alimentar/imunologia , Imunoglobulina E/imunologia , Humanos
11.
World J Gastroenterol ; 21(35): 10080-90, 2015 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-26401073

RESUMO

AIM: To investigate whether accelerated catabolism of ganglioside and decreased ganglioside content contribute to the etiology of pro-inflammatory intestinal disease. METHODS: Intestinal mucosa from terminal ileum or colon was obtained from patients with ulcerative colitis or inflammatory Crohn's disease (n = 11) undergoing bowel resection and compared to control samples of normal intestine from patients with benign colon polyps (n = 6) and colorectal cancer (n = 12) in this observational case-control study. Gangliosides and phospholipids of intestinal mucosa were characterized by class and ceramide or fatty acid composition using liquid chromatography triple-quad mass spectrometry. Content and composition of ganglioside classes GM1, GM3, GD3, GD1a, GT1 and GT3 were compared among subject groups. Content and composition of phospholipid classes phosphatidylcholine (PC) and phosphatidylethanolamine were compared among subject groups. Unsaturation index of individual ganglioside and phospholipid classes was computed and compared among subject groups. Ganglioside catabolism enzymes beta-hexosaminidase A (HEXA) and sialidase-3 (NEU3) were measured in intestinal mucosa using western blot and compared among subject groups. RESULTS: Relative GM3 ganglioside content was 2-fold higher (P < 0.05) in intestine from patients with inflammatory bowel disease (IBD) compared to control intestine. The quantity of GM3 and ratio of GM3/GD3 was also higher in IBD intestine than control tissue (P < 0.05). Control intestine exhibited 3-fold higher (P < 0.01) relative GD1a ganglioside content than IBD intestine. GD3 and GD1a species of ganglioside containing three unsaturated bonds were present in control intestine, but were not detected in IBD intestine. The relative content of PC containing more than two unsaturated bonds was 30% lower in IBD intestine than control intestine (P < 0.05). The relative content of HEXA in IBD intestine was increased 1.7-fold (P < 0.05) and NEU3 was increased 8.3-fold (P < 0.01) compared to normal intestine. Intestinal mucosa in IBD is characterized by increased GM3 content, decreased GD1a, and a reduction in polyunsaturated fatty acid constituents in GD3, GD1a and PC. CONCLUSION: This study suggests a new paradigm by proposing that IBD occurs as a consequence of increased metabolism of specific gangliosides.


Assuntos
Colite Ulcerativa/metabolismo , Colo/química , Doença de Crohn/metabolismo , Ácidos Graxos Insaturados/análise , Gangliosídeos/análise , Íleo/química , Mucosa Intestinal/química , Estudos de Casos e Controles , Colite Ulcerativa/cirurgia , Colo/cirurgia , Doença de Crohn/cirurgia , Gangliosídeo G(M3)/análise , Humanos , Íleo/cirurgia , Mucosa Intestinal/cirurgia , Neuraminidase/análise , Fosfatidilcolinas/análise , Fosfatidiletanolaminas/análise , Cadeia alfa da beta-Hexosaminidase/análise
13.
Cardiovasc Toxicol ; 3(2): 89-99, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14501028

RESUMO

The clinically approved antioxidant cardioprotective agent dexrazoxane (ICRF-187) was examined for its ability to protect neonatal rat cardiac myocytes from doxorubicin-induced damage. Doxorubicin is thought to induce oxidative stress on the heart muscle, both through reductive activation to its semiquinone form, and by the production of hydroxyl radicals mediated by its complex with iron. Hydrolyzed dexrazoxane metabolites prevent site-specific iron-based oxygen radical damage by displacing iron from doxorubicin and chelating free and loosely bound iron. The mitochondrial stain MitoTracker Green FM and doxorubicin were shown by epifluorescence microscopy to accumulate in the myocyte mitochondria. An epifluorescence microscopic image analysis method to measure mitochondrial damage was developed using the mitochondrial membrane potential sensing ratiometric dye JC-1. This method was used to show that dexrazoxane protected against doxorubicin-induced depolarization of the myocyte mitochondrial membrane. Dexrazoxane also attenuated doxorubicin-induced oxidation of intracellular dichlorofluorescin. Annexin V-FITC/propidium iodide staining of myocytes was used to demonstrate that, depending on the concentration, doxorubicin caused both apoptotic and necrotic damage. These results suggest that doxorubicin may be cardiotoxic by damaging the mitochondria and dexrazoxane may be protective by preventing iron-based oxidative damage.


Assuntos
Fármacos Cardiovasculares/farmacologia , Doxorrubicina/toxicidade , Mitocôndrias Cardíacas/efeitos dos fármacos , Miócitos Cardíacos/efeitos dos fármacos , Razoxano/farmacologia , Animais , Animais Recém-Nascidos , Apoptose/efeitos dos fármacos , Células Cultivadas , Relação Dose-Resposta a Droga , Doxorrubicina/metabolismo , Interações Medicamentosas , Ventrículos do Coração/efeitos dos fármacos , Ventrículos do Coração/metabolismo , Ventrículos do Coração/patologia , Processamento de Imagem Assistida por Computador , Indicadores e Reagentes/metabolismo , Membranas Intracelulares/efeitos dos fármacos , Potenciais da Membrana/efeitos dos fármacos , Mitocôndrias Cardíacas/patologia , Miócitos Cardíacos/metabolismo , Miócitos Cardíacos/patologia , Necrose , Ratos , Ratos Sprague-Dawley , Espécies Reativas de Oxigênio/metabolismo
14.
Clin Biochem ; 47(12): 1116-20, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24792455

RESUMO

OBJECTIVE: Adaptation of the Randox Enzymatic Manual UV Ammonia method to be used on the Roche Cobas 6000 (c501) automated analyzer platform. DESIGN AND METHODS: The Randox ammonia reagent was evaluated for precision, linearity, accuracy and interference from hemolysis, icterus and lipemia on the Roche c501 analyzer. Comparison studies were conducted for the Randox reagent between Roche c501, Siemens Vista, Ortho Vitros 250, and Beckman DxC methods. RESULTS: The Randox reagent demonstrates acceptable within-run (L1=65 µmol/L, CV 3.4% L2=168 µmol/L, CV 1.9%) and between-run precision (L1=29 µmol/L, CV 7.3% L2=102 µmol/L, CV 3.0%), Analytical Measurement Range (7-940 µmol/L), and accuracy. The method interference profile is superior for the Randox method (hemolysis index up to 600, icteric index up to 60, lipemic index up to 100) as compared to the Roche method (hemolysis index up to 200, icteric index up to 10, lipemic index up to 50). Comparison was very good between the Randox reagent and two other wet chemistry platforms. CONCLUSIONS: The Randox Enzymatic Manual UV Ammonia reagent is an available alternative to the Roche Cobas c501 reagent. The method is more robust to endogenous interferences and less prone to instrument error flags, thus allowing the majority of clinical specimens to be reported without additional sample handling at our institution.


Assuntos
Amônia/análise , Automação , Humanos
15.
Anticancer Res ; 32(1): 259-63, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22213314

RESUMO

BACKGROUND: A novel method to measure 1,25-dihydroxyvitamin D (1,25(OH)(2)D) in human tissue was developed and validated. The objectives of this study were to determine whether 1,25(OH)(2)D is present in human colon tissue and to characterize the relationship between human colon tissue and serum 1,25(OH)(2)D concentrations. MATERIALS AND METHODS: Normal colon tissue specimens and matched serum samples were obtained from 30 patients who had undergone colectomy. Colon 1,25(OH)(2)D was measured by lipid extraction followed by enzyme immunoassay (EIA). Serum 1,25(OH)(2)D and 25-hydroxyvitamin D (25(OH)D) were measured by EIA. Vitamin D binding protein (DBP) was measured in a subset of serum and tissue samples. RESULTS: Regression analysis indicated a significant positive correlation between serum and colon 1,25(OH)(2)D concentrations (r=0.58, p=0.0008). The corresponding intercept at zero serum 1,25(OH)(2)D was 21.5 pmol/kg (95% CI=16.95-25.98; p<0.001). Colon 1,25(OH)(2)D did not correlate significantly with serum 25(OH)D. DBP levels in tissue samples were negligible. CONCLUSION: The hormone 1,25(OH)(2)D can be successfully detected in human colon at physiologically relevant concentrations, partly determined by serum 1,25(OH)(2)D. The results support the notion of in vivo synthesis of 1,25(OH)(2)D within colon tissues.


Assuntos
Colo/metabolismo , Mucosa/metabolismo , Proteína de Ligação a Vitamina D/metabolismo , Vitamina D/análogos & derivados , Humanos , Técnicas Imunoenzimáticas , Vitamina D/análise , Proteína de Ligação a Vitamina D/sangue
16.
Clin Biochem ; 45(3): 264-6, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22178109

RESUMO

INTRODUCTION: Hemoglobinopathies and thalassemias together form the most common genetic disease in the world. Double heterozygosity, in which there is a hemoglobin variant, in both the α- and non-α globin chains, is very unusual. A novel double heterozygosity of the α chain variant HbQ India with the non-α chain HbD Punjab is described. METHODS AND MATERIALS: The index case is a 39 year old female of Indian origin. HPLC analysis using the Bio Rad ß thalassemia method and electrophoresis at both alkaline and acid pH were performed. RESULTS: HPLC shows four major bands and electrophoresis at alkaline pH shows 3 bands and 2 bands at acid pH. DISCUSSION: Both the HPLC and electrophoresis at alkaline and acid pH are consistent for the double heterozygous hemoglobin variants HbQ India and HbD Punjab. CONCLUSION: This is the first literature report of the double heterozygosity of HbQ India/HbD Punjab.


Assuntos
Hemoglobinopatias/genética , Hemoglobinas Anormais/genética , Heterozigoto , Cromatografia Líquida de Alta Pressão , Eletroforese , Feminino , Humanos , Concentração de Íons de Hidrogênio , Índia
17.
J Nutr Metab ; 2012: 280286, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22506104

RESUMO

Gangliosides are integral to the structure and function of cell membranes. Ganglioside composition of the intestinal brush border and apical surface of the colon influences numerous cell processes including microbial attachment, cell division, differentiation, and signaling. Accelerated catabolism of ganglioside in intestinal disease results in increased proinflammatory signaling. Restoring proper structure and function to the diseased intestine can resolve inflammation, increase resistance to infection, and improve gut integrity to induce remission of conditions like necrotizing enterocolitis (NEC) and Crohn's disease (CD). Maintaining inactive state of disease may be achieved by reducing the rate that gangliosides are degraded or by increasing intake of dietary ganglioside. Collectively, the studies outlined in this paper indicate that the amount of gangliosides GM3 and GD3 in intestinal mucosa is decreased with inflammation, low level of GM3 is associated with higher production of proinflammatory signals, and ganglioside content of intestinal mucosa can be increased by dietary ganglioside.

18.
J Steroid Biochem Mol Biol ; 126(3-5): 72-7, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21605672

RESUMO

24,25-Dihydroxyvitamin D (24,25VD) is a major catabolite of 25-hydroxyvitamin D (25VD) metabolism, and may be physiologically active. Our objectives were to: (1) characterize the response of serum 24,25VD(3) to vitamin D(3) (VD(3)) supplementation; (2) test the hypothesis that a higher 24,25VD(3) to 25VD(3) ratio (24,25:25VD(3)) predicts 25VD(3) response. Serum samples (n=160) from wk 2 and wk 6 of a placebo-controlled, randomized clinical trial of VD(3) (28,000IU/wk) were analyzed for serum 24,25VD(3) and 25VD(3) by mass spectrometry. Serum 24,25VD(3) was highly correlated with 25VD(3) in placebo- and VD(3)-treated subjects at each time point (p<0.0001). At wk 2, the 24,25:25VD(3) ratio was lower with VD(3) than with placebo (p=0.035). From wk 2 to wk 6, the 24,25:25VD(3) ratio increased with the VD(3) supplement (p<0.001) but not with placebo, such that at wk 6 this ratio did not significantly differ between groups. After correcting for potential confounders, we found that 24,25:25VD(3) at wk 2 was inversely correlated to the 25VD(3) increment by wk 6 in the supplemented group (r=-0.32, p=0.02) but not the controls. There is a strong correlation between 24,25VD(3) and 25VD(3) that is only modestly affected by VD(3) supplementation. This indicates that the catabolism of 25VD(3) to 24,25VD(3) rises with increasing 25VD(3). Furthermore, the initial ratio of serum 24,25VD(3) to 25VD(3) predicted the increase in 25VD(3). The 24,25:25VD(3) ratio may therefore have clinical utility as a marker for VD(3) catabolism and a predictor of serum 25VD(3) response to VD(3) supplementation.


Assuntos
24,25-Di-Hidroxivitamina D 3/sangue , Colecalciferol/uso terapêutico , Suplementos Nutricionais , Vitamina D/análogos & derivados , 24,25-Di-Hidroxivitamina D 3/análise , Adulto , Biomarcadores Farmacológicos/análise , Biomarcadores Farmacológicos/sangue , Colecalciferol/administração & dosagem , Cromatografia Líquida , Método Duplo-Cego , Feminino , Humanos , Masculino , Placebos , Espectrometria de Massas em Tandem , Fatores de Tempo , Vitamina D/análise , Vitamina D/sangue , Adulto Jovem
19.
Clin Biochem ; 43(12): 1026-9, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20416292

RESUMO

OBJECTIVE: To evaluate the analytical performance of the Nova StatSensor creatinine meter. DESIGN AND METHODS: Imprecision, linearity, patient correlation and interference studies were completed. RESULTS: Total imprecision was 4.5-9.1%CV and a linear measurement range of 93-863 micromol/L (1.05-9.76 mg/dL) was verified. Whole blood creatinine results correlated well with laboratory plasma measurements (R(2)=0.9328) but exhibited a negative proportional bias. In vitro, high levels of creatine and urea falsely elevated creatinine measurement. CONCLUSIONS: The creatinine meter provides reliable measurement across a clinically relevant range and has potential use in point-of-care testing.


Assuntos
Creatinina/sangue , Fitas Reagentes , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Reprodutibilidade dos Testes
20.
Clin Biochem Rev ; 29(3): 89-96, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19107221

RESUMO

Screening, diagnosis and monitoring of paediatric diseases relies on the measurement of a spectrum of disease biomarkers in clinical laboratories to guide important clinical decisions. Physicians rely on the availability of suitable and reliable reference intervals to accurately interpret laboratory test results with data collected during medical history and physical examination. However, critical gaps currently exist in accurate and up-to-date reference intervals (normal values) for accurate interpretation of laboratory tests performed in children and adolescents. These gaps in the available paediatric laboratory reference intervals have the clear potential of contributing to erroneous diagnosis or misdiagnosis of many diseases of childhood and adolescence. Most of the available reference intervals for laboratory tests were determined over two decades ago on older instruments and technologies, and are no longer relevant considering the current testing technology used by clinical laboratories. It is thus critical and of utmost urgency that a more acceptable and comprehensive database be established. There are however many challenges when attempting to establish paediatric reference intervals. Paediatric specimen collection is a major concern for health care providers as it is frequently difficult to obtain sufficient volumes of blood or urine from paediatric patients. Common reference intervals have not been widely implemented due to lack of harmonisation of methods and differences in patient populations. Consequently, clinical laboratory accreditation organisations and licensing agencies require that each laboratory verify or establish reference intervals for each method. To provide such reference intervals requires selection criteria for suitable reference individuals, defined conditions for specimen collection and analysis, method selection to determine reference limits and validation of the reference interval. The current review will provide a brief introduction to the current approach to establishment of reference intervals, will highlight the current gaps in data available in paediatric populations, and review a recent Canadian initiative, CALIPER (Canadian Laboratory Initiative on Paediatric Reference Intervals), to establish a comprehensive database for both traditional and emerging biomarkers of paediatric disease.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA