Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J ; 43(7): 641-650, 2022 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-34463727

RESUMO

AIMS: Severe mitral regurgitation (MR) following acute myocardial infarction (MI) is associated with high mortality rates and has inconclusive recommendations in clinical guidelines. We aimed to report the international experience of patients with secondary MR following acute MI and compare the outcomes of those treated conservatively, surgically, and percutaneously. METHODS AND RESULTS: Retrospective international registry of consecutive patients with at least moderate-to-severe MR following MI treated in 21 centres in North America, Europe, and the Middle East. The registry included patients treated conservatively and those having surgical mitral valve repair or replacement (SMVR) or percutaneous mitral valve repair (PMVR) using edge-to-edge repair. The primary endpoint was in-hospital mortality. A total of 471 patients were included (43% female, age 73 ± 11 years): 205 underwent interventions, of whom 106 were SMVR and 99 PMVR. Patients who underwent mitral valve intervention were in a worse clinical state (Killip class ≥3 in 60% vs. 43%, P < 0.01), but yet had lower in-hospital and 1-year mortality compared with those treated conservatively [11% vs. 27%, P < 0.01 and 16% vs. 35%, P < 0.01; adjusted hazard ratio (HR) 0.28, 95% confidence interval (CI) 0.18-0.46, P < 0.01]. Surgical mitral valve repair or replacement was performed earlier than PMVR [median of 12 days from MI date (interquartile range 5-19) vs. 19 days (10-40), P < 0.01]. The immediate procedural success did not differ between SMVR and PMVR (92% vs. 93%, P = 0.53). However, in-hospital and 1-year mortality rates were significantly higher in SMVR than in PMVR (16% vs. 6%, P = 0.03 and 31% vs. 17%, P = 0.04; adjusted HR 3.75, 95% CI 1.55-9.07, P < 0.01). CONCLUSIONS: Early intervention may mitigate the poor prognosis associated with conservative therapy in patients with post-MI MR. Percutaneous mitral valve repair can serve as an alternative for surgery in reducing MR for high-risk patients.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Infarto do Miocárdio , Idoso , Idoso de 80 Anos ou mais , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/cirurgia , Infarto do Miocárdio/complicações , Infarto do Miocárdio/terapia , Estudos Retrospectivos , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 97(6): 1259-1267, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33600072

RESUMO

OBJECTIVES: To assess outcomes in patients with acute mitral regurgitation (MR) following acute myocardial infarction (AMI) who received percutaneous mitral valve repair (PMVR) with the MitraClip device and to compare outcomes of patients who developed cardiogenic shock (CS) to those who did not (non-CS). BACKGROUND: Acute MR after AMI may lead to CS and is associated with high mortality. METHODS: This registry analyzed patients with MR after AMI who were treated with MitraClip at 18 centers within eight countries between January 2016 and February 2020. Patients were stratified into CS and non-CS groups. Primary outcomes were mortality and rehospitalization due to heart failure. Secondary outcomes were acute procedural success, functional improvement, and MR reduction. Multivariable Cox regression analysis evaluated association of CS with clinical outcomes. RESULTS: Among 93 patients analyzed (age 70.3 ± 10.2 years), 50 patients (53.8%) experienced CS before PMVR. Mortality at 30 days (10% CS vs. 2.3% non-CS; p = .212) did not differ between groups. After median follow-up of 7 months (IQR 2.5-17 months), the combined event mortality/re-hospitalization was similar (28% CS vs. 25.6% non-CS; p = .793). Likewise, immediate procedural success (90% CS vs. 93% non-CS; p = .793) and need for reintervention (CS 6% vs. non-CS 2.3%, p = .621) or re-admission due to HF (CS 13% vs. NCS 23%, p = .253) at 3 months did not differ. CS was not independently associated with the combined end-point (hazard ratio 1.1; 95% CI, 0.3-4.6; p = .889). CONCLUSIONS: Patients found to have significant MR during their index hospitalization for AMI had similar clinical outcomes with PMVR whether they presented in or out of cardiogenic shock, provided initial hemodynamic stabilization was first achieved before PMVR.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Infarto do Miocárdio , Idoso , Idoso de 80 Anos ou mais , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Infarto do Miocárdio/complicações , Sistema de Registros , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Resultado do Tratamento
3.
Heart Vessels ; 35(4): 487-501, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31642980

RESUMO

Early and long-term outcomes in elderly patients who underwent isolated aortic valve replacement (iAVR) are well defined. Conflicting data exist in elderly patients who underwent AVR plus coronary artery bypass grafting (CABG). We sought to evaluate the early and long-term outcomes of combined AVR + CABG in patients older than 75 years of age. From June 1999 to June 2018, 402 patients ≥ 75 years who underwent iAVR (n = 200; 49.7%) or combined AVR plus CABG (n = 202; 50.3%) were retrospectively analysed. AVR + CABG patients were older than iAVR patients (78.5 ± 2.5 vs 77.6 ± 2.8 years; p < 0.0001), with greater co-morbidities and more urgent/emergency surgery. 30-day mortality was 6.5% in the AVR + CABG and 4.5% in the iAVR group (p = 0.38). Multivariate analysis identified EuroSCORE II [odd ratio (OR) 1.13] postoperative stroke (OR 12.53), postoperative low cardiac output syndrome (OR 8.72) and postoperative mechanical ventilation > 48 h (OR 8.92) as independent predictors of 30-day mortality; preoperative cerebrovascular events (OR 3.43), creatinine (OR 7.27) and extracorporeal circulation time (OR 1.01) were independent predictors of in-hospital major adverse cardiovascular and cerebral events (MACCE). Treatment was not an independent predictor of 30-day mortality and in-hospital MACCE. Survival at 1, 5 and 10 years was 94.7 ± 1.6%, 72.6 ± 3.6% and 31.7 ± 4.8% for iAVR patients and 89.1 ± 2.3%, 73.9 ± 3.5% and 37.2 ± 4.8% for AVR + CABG subjects (p = 0.99). Using adjusted Cox regression model, creatinine [hazard ration (HR) 1.50; p = 0.018], COPD (HR 1.97; p = 0.003) and NYHA class (HR 1.39; p < 0.0001) were independent predictors of late mortality; the combined AVR + CABG was not associated with increased risk of late mortality (HR 0.83; p = 0.30). In patients aged ≥ 75 years, combined AVR + CABG was not associated with increased 30-day mortality, in-hospital MACCE and long-term mortality. Surgical revascularization can be safely undertaken at the time of AVR in elderly patients.


Assuntos
Valva Aórtica/cirurgia , Ponte de Artéria Coronária/estatística & dados numéricos , Doenças das Valvas Cardíacas/cirurgia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Ponte de Artéria Coronária/efeitos adversos , Feminino , Doenças das Valvas Cardíacas/mortalidade , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Modelos Logísticos , Masculino , Análise Multivariada , Complicações Pós-Operatórias/etiologia , Qualidade de Vida , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
J Clin Microbiol ; 56(6)2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29618501

RESUMO

The National Institute of Allergy and Infectious Diseases (NIAID) AIDS Clinical Trials Group (ACTG) stores specimens from its clinical trials in a biorepository and permits the use of these specimens for nonprotocol exploratory studies, once the studies for the original protocol are concluded. We sought to assess the comparability of the data generated from real-time HIV-1 RNA testing during two clinical trials with the data generated from the retesting of different aliquots of the same samples after years of storage at -80°C. Overall, there was 92% agreement in the data generated for 1,570 paired samples (kappa statistic = 0.757; 95% confidence interval [CI], 0.716 to 0.797), where samples were tested in one laboratory using the microwell plate (MWP) version of the Roche HIV-1 Monitor test within 1 to 37 days of collection and retested in another laboratory using the Cobas version of the assay after a median of 6.7 years of storage (range, 5.7 to 8.6 years). Historical external quality control data submitted to the NIAID Virology Quality Assurance program (VQA) by client laboratories using the same two versions of the Monitor assay were used to differentiate between systematic differences in the assays to evaluate the stability of HIV-1 RNA in the stored samples. No significant loss of RNA was noted in samples containing either a low concentration (<50 copies/ml) or a high concentration (≥50 copies/ml) of HIV-1 RNA (P = 0.10 and P = 0.90, respectively) regardless of the time in storage. These data confirm the quality of the plasma samples in the ACTG biorepository following long-term storage.


Assuntos
HIV-1/genética , Laboratórios , Controle de Qualidade , Estabilidade de RNA , RNA Viral/genética , Manejo de Espécimes/normas , Bancos de Espécimes Biológicos , Análise de Dados , Infecções por HIV/sangue , Infecções por HIV/virologia , Humanos , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade , Carga Viral
5.
J Clin Med ; 10(9)2021 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-33921996

RESUMO

Patients with severe mitral regurgitation (MR) after myocardial infarction (MI) have an increased risk of mortality. Transcatheter mitral valve repair may therefore be a suitable therapy. However, data on clinical outcomes of patients in an acute setting are scarce, especially those with reduced left ventricle (LV) dysfunction. We conducted a multinational, collaborative data analysis from 21 centers for patients who were, within 90 days of acute MI, treated with MitraClip due to severe MR. The cohort was divided according to median left ventricle ejection fraction (LVEF)-35%. Included in the study were 105 patients. The mean age was 71 ± 10 years. Patients in the LVEF < 35% group were younger but with comparable Euroscore II, multivessel coronary artery disease, prior MI and coronary artery bypass graft surgery. Procedure time was comparable and acute success rate was high in both groups (94% vs. 90%, p = 0.728). MR grade was significantly reduced in both groups along with an immediate reduction in left atrial V-wave, pulmonary artery pressure and improvement in New York Heart Association (NYHA) class. In-hospital and 1-year mortality rates were not significantly different between the two groups (11% vs. 7%, p = 0.51 and 19% vs. 12%, p = 0.49) and neither was the 3-month re-hospitalization rate. In conclusion, MitraClip intervention in patients with acute severe functional mitral regurgitation (FMR) due to a recent MI in an acute setting is safe and feasible. Even patients with severe LV dysfunction may benefit from transcatheter mitral valve intervention and should not be excluded.

6.
Expert Rev Cardiovasc Ther ; 17(12): 841-856, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31795771

RESUMO

Introduction: Transcatheter tricuspid valve (TV) procedures emerged as an alternative to surgery for symptomatic high-risk patients with severe tricuspid regurgitation.Areas covered: A literature search was performed using PubMed. Authors review clinical evidence in this field, the imaging features and the developments in TV transcatheter technologies. Currently, transcatheter devices for TV procedures can be allocated into four main groups: 1) those ones targeting leaflet malcoaptation, 2) those addressing annular dilatation, 3) those performing heterotopic valve implantation and 4) those onesaccomplishing a complete transcatheter replacement of the valve.Expert opinion: Actually, encouraging results are provided by initial experience in the field of transcatheter TV procedures. However, this field remains full of challenges that faced could lead to better results and prognosis for the patients. The next steps in this emerging field will need to focus on accurate patient selection, an early patient referral and on studies comparable and providing long-term data.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Cateterismo Cardíaco/métodos , Humanos , Seleção de Pacientes , Resultado do Tratamento
7.
J Thorac Cardiovasc Surg ; 158(1): 141-151, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30745048

RESUMO

BACKGROUND: Long-term survival benefits of full arterial revascularization with radial artery (RA) used in addition to bilateral internal mammary arteries (BIMA) compared with saphenous vein (SV) used in addition to BIMA has not been clearly defined. METHODS: We retrospectively analyzed 660 3-vessel coronary artery disease subjects who received BIMA in addition to either RA (n = 206) or SV (n = 454) grafting in a period between June 1999 and November 2017. After propensity score matching, we obtained 190 matched pairs for analysis. RESULTS: In the matched population, in-hospital mortality occurred in 4 patients (1%), with 2 deaths (1.1%) in the BIMA + RA group and 2 deaths (1.1%) in BIMA + SV group (P > .99). The median follow-up time was 9.2 years (interquartile range, 5.6-13 years) with a maximum follow-up time of 18.5 years. There was not a significant difference in long-term survival between the 2 groups over the follow-up period. Survival at 5, 10, and 15 years were 94.8 ± 1.7%, 83.7 ± 3.1%, and 78.6 ± 3.9% in the BIMA + RA group and 96.2 ± 1.4%, 85.1 ± 2.9%, and 80.4 ± 3.6% in the BIMA + SV group (stratified log-rank P = .78). Cox proportional hazard regression model was used to estimate that the use of RA in addition to BIMA did not affect the late mortality (propensity score adjusted hazard ratio, 1.05; 95% confidence interval, 0.62-1.79; P = .83). CONCLUSIONS: In a relatively small population of triple-vessel coronary artery disease, the use of RA as a third arterial conduit with BIMA did not confer a long-term survival benefit.


Assuntos
Ponte de Artéria Coronária/métodos , Artéria Torácica Interna/transplante , Artéria Radial/transplante , Veia Safena/transplante , Ponte de Artéria Coronária/mortalidade , Doença da Artéria Coronariana/cirurgia , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Análise de Sobrevida
8.
J Virol Methods ; 261: 91-97, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30125614

RESUMO

BACKGROUND: Commercially-available kits for HIV-1 detection include instructions for detecting HIV-1 in plasma and DBS, but don't support other specimen types. OBJECTIVES: Show quantitative stability of HIV-1 total nucleic acid (TNA) in blood and improved HIV-1 detection in alternative specimen types. STUDY DESIGN: Whole blood and DBS specimens, tested as part of an external quality assurance program for qualitative HIV-1 detection, were used to evaluated error rates (false negative [FN], false positive [FP] and indeterminant [IND] results) across assays (internally developed [IH], Roche Amplicor [RA], and Roche TaqMan Qual [TQ]) and specimen types (frozen whole blood [BLD], DBS and cell pellets [PEL]). A modified Roche TaqMan HIV-1 assay was used to quantify HIV-1 TNA. RESULTS: Significantly higher error rates were noted in DBS across all of the assays (4% vs. 0% for DBS and PEL, IH, p = 0.005; 4% vs. 0.1% for DBS and PEL, RA, p < 0.001; 10% vs. 1% for DBS and PEL or BLD, TQ, p < 0.001). HIV TNA concentration is stable in BLD (day 1 vs. day 10, p = 0.39) and higher than DBS (p < 0.001). CONCLUSIONS: Transporting refrigerated whole blood for centralized processing into alternative specimen types will improve the sensitivitiy of HIV-1 detection in samples with low virus loads.


Assuntos
Infecções por HIV/diagnóstico , HIV-1/isolamento & purificação , RNA Viral/análise , Manejo de Espécimes/métodos , Erros de Diagnóstico , HIV-1/genética , RNA Viral/genética , Sensibilidade e Especificidade
10.
J Clin Microbiol ; 43(8): 4249-50, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16081991

RESUMO

The Roche Amplicor HIV-1 Test requires that whole blood be processed within four days of collection. However, this requirement may be too limiting for use in international settings. Thus, we demonstrate that blood may be processed up to 10 days after collection if maintained under ambient conditions (2 to 25 degrees C).


Assuntos
Preservação de Sangue , DNA Viral/sangue , HIV-1/genética , Provírus/genética , DNA Viral/química , Humanos , Temperatura
11.
J Clin Microbiol ; 43(12): 5950-6, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16333081

RESUMO

Human immunodeficiency virus (HIV) RNA testing is the gold standard for monitoring antiretroviral therapy in HIV-infected patients. However, equipment and reagent costs preclude widespread use of the assay in resource-limited settings. The Perkin-Elmer Ultrasensitive p24 assay and the Cavidi Exavir Load assay both offer potentially simpler, less costly technologies for monitoring viral load. These assays were compared to the Roche Amplicor HIV-1 Monitor Test, v1.5, using panels of clinical samples (subtype B) from HIV-positive subjects and HIV-spiked samples (subtypes A, C, D, CRF_01AE, CRF_02AG, and F). The Ultrasensitive p24 assay detected 100% of the spiked samples with virus loads of >250,000 copies/ml and 61% of the clinical samples with virus loads of 219 to 288,850 copies/ml. Detection rates were improved substantially if an external lysis buffer was added to the procedure. The Cavidi assay detected 54 to 100% of spiked samples with virus loads >10,000 copies/ml and 68% of the clinical samples. These detection rates were also greatly improved with a newly implemented version of this kit. Coefficients of variation demonstrate good reproducibility for each of these kits. The results from the Cavidi v1.0, Cavidi v2.0, and Perkin-Elmer, and the Perkin-Elmer Plus external buffers all correlated well with the results from the Roche Monitor Test (r = 0.83 to 0.96, r = 0.84 to 0.99, r = 0.58 to 0.67, and r = 0.59 to 0.95, respectively). Thus, the use of these two assays for monitoring patients, together with less-frequent confirmation testing, offers a feasible alternative to frequent HIV RNA testing in resource-limited settings.


Assuntos
Proteína do Núcleo p24 do HIV/sangue , Infecções por HIV/diagnóstico , HIV-1/fisiologia , RNA Viral/sangue , Kit de Reagentes para Diagnóstico , Infecções por HIV/virologia , Transcriptase Reversa do HIV/metabolismo , HIV-1/enzimologia , HIV-1/genética , Humanos , Kit de Reagentes para Diagnóstico/economia , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Carga Viral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA