Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
Echocardiography ; 41(1): e15709, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37922229

RESUMO

Double orifice mitral valve is a rare congenital anomaly that is often associated with other congenital cardiac abnormalities. Patients may present with valvular dysfunction or may be asymptomatic and have an incidental diagnosis of double outlet mitral valve. Whether symptoms due to this pathology are present or not it is important to accurately characterize this lesion. Three-dimensional imaging is a powerful diagnostic modality for diagnosing and characterizing lesions such as this as highlighted in this case image series where we describe how three-dimensional transesophageal echocardiography was utilized to characterize both complete and incomplete bridge type double orifice mitral valve.


Assuntos
Ecocardiografia Tridimensional , Cardiopatias Congênitas , Doenças das Valvas Cardíacas , Humanos , Valva Mitral , Ecocardiografia Transesofagiana , Cardiopatias Congênitas/diagnóstico
2.
J Cardiothorac Vasc Anesth ; 38(7): 1460-1466, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38580474

RESUMO

OBJECTIVES: This study aimed to evaluate the accuracy of identifying the true aortic valve (AV) annulus using 2-dimensional (2D) echocardiography, with the goal of highlighting potential misidentification issues in clinical practice. DESIGN: An observational study employing 3-dimensional (3D) datasets to generate 2D images of the AV annulus for analysis. SETTING: The study was conducted in an academic medical center. PARTICIPANTS: Three-dimensional transesophageal echocardiography datasets were obtained from 11 patients with normal AV and aortic root anatomies undergoing coronary artery bypass surgery. Attending anesthesiologists certified by the National Board of Echocardiography (NBE) were approached subsequently to participate in this study. INTERVENTIONS: Two images per patient were generated from 3D datasets, reflecting the mid-esophageal long-axis view of the AV, a true AV annulus image, and an off-axis image. A survey was distributed to NBE-certified perioperative echocardiographers across 12 academic institutions to identify the true AV annulus from these images. MEASUREMENTS AND MAIN RESULTS: The survey, completed by 45 qualified respondents, revealed a significant misidentification rate of the true AV annulus, with only 36.8% of responses correctly identifying it. The rate of correct identification varied across image sets, with 44.4% of participants unable to correctly identify any true AV annulus image. CONCLUSIONS: The study highlighted the limitations of 2D echocardiography in accurately identifying the true AV annulus in complex 3D structures like the aortic root. The findings suggest a need for greater reliance on advanced imaging modalities, such as 3D echocardiography, to improve accuracy in clinical practice.


Assuntos
Valva Aórtica , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Ecocardiografia Tridimensional/métodos , Ecocardiografia Tridimensional/normas , Ecocardiografia Transesofagiana/métodos , Ecocardiografia Transesofagiana/normas , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Ecocardiografia/métodos , Ecocardiografia/normas
3.
J Cardiothorac Vasc Anesth ; 38(9): 2070-2079, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38918095

RESUMO

The incorporation of 3D imaging into diagnostic and interventional echocardiography has rapidly expanded in recent years. Applications such as multiplanar reconstruction that were once considered research tools and required off-cart analysis can now readily be performed at the point of image acquisition and in real-time during live image acquisition for procedural guidance. While the application and quality of 3D images have significantly improved in recent years, there remains a noticeable lag in the evolution of artificial intelligence that would further simplify the interpretative processes, both during live sessions and offline analyses. Users are still required to mentally reconstruct sliced images during multiplanar reconstruction based on color-coded planes. While this may be an effortless task for the seasoned echocardiographer, it can be a challenging task for echocardiographers who are less familiar with 3D imaging and multiplanar reconstruction. This article describes the utility of using 3D markers to aid in image interpretation.


Assuntos
Ecocardiografia Tridimensional , Humanos , Ecocardiografia Tridimensional/métodos , Ecocardiografia Tridimensional/normas , Processamento de Imagem Assistida por Computador/métodos
4.
J Cardiothorac Vasc Anesth ; 38(3): 755-770, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38220517

RESUMO

OBJECTIVES: To investigate whether implementation of a multidisciplinary protocol for ruptured abdominal aortic aneurysm (rAAA) management reduces rates of adverse complications. DESIGN: A retrospective before-after study. SETTING: A tertiary-care academic hospital. PARTICIPANTS: Adult patients who underwent open or endovascular rAAA repair; data were stratified into before-protocol implementation (group 1: 2015-2018) and after-protocol implementation (group 2: 2019-2022) groups. INTERVENTION: The protocol details the workflow for vascular surgery, anesthesia, emergency department, and operating room staff for a rAAA case; training was accomplished through yearly workshops. MEASUREMENTS AND MAIN RESULTS: The primary outcome was in-hospital mortality. Secondary outcomes included all-cause morbidity and other major complications. Differences in postoperative complication rates between groups were assessed using Pearson's χ2 test. Of the 77 patients included undergoing rAAA repair, 41 (53.2%) patients were in group 1, and 36 (46.8%) patients were in group 2. Patients in group 2 had a significantly shorter median time to incision (1.0 v 0.7 hours, p = 0.022) and total procedure time (180.0 v 160.5 minutes, p = 0.039) for both endovascular and open repair. After protocol implementation, patients undergoing endovascular repair exhibited significantly lower rates of mortality (46.2% v 20.0%, p = 0.048), all-cause morbidity (65.4% v 44.0%, p = 0.050), and renal complications (15.4% v 0.0%, p = 0.036); patients undergoing open repair for a rAAA exhibited significantly lower rates of mortality (53.3% v 27.3%, p = 0.018) and bowel ischemia (26.7% v 0.0%, p = 0.035). CONCLUSIONS: Implementation of a multidisciplinary protocol for the management of a rAAA may reduce rates of adverse complications and improve the quality of care.


Assuntos
Aneurisma da Aorta Abdominal , Ruptura Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Estudos Retrospectivos , Estudos Controlados Antes e Depois , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/métodos , Resultado do Tratamento , Ruptura Aórtica/cirurgia , Complicações Pós-Operatórias/etiologia , Fatores de Risco
5.
J Cardiothorac Vasc Anesth ; 38(5): 1251-1259, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38423884

RESUMO

New artificial intelligence tools have been developed that have implications for medical usage. Large language models (LLMs), such as the widely used ChatGPT developed by OpenAI, have not been explored in the context of anesthesiology education. Understanding the reliability of various publicly available LLMs for medical specialties could offer insight into their understanding of the physiology, pharmacology, and practical applications of anesthesiology. An exploratory prospective review was conducted using 3 commercially available LLMs--OpenAI's ChatGPT GPT-3.5 version (GPT-3.5), OpenAI's ChatGPT GPT-4 (GPT-4), and Google's Bard--on questions from a widely used anesthesia board examination review book. Of the 884 eligible questions, the overall correct answer rates were 47.9% for GPT-3.5, 69.4% for GPT-4, and 45.2% for Bard. GPT-4 exhibited significantly higher performance than both GPT-3.5 and Bard (p = 0.001 and p < 0.001, respectively). None of the LLMs met the criteria required to secure American Board of Anesthesiology certification, according to the 70% passing score approximation. GPT-4 significantly outperformed GPT-3.5 and Bard in terms of overall performance, but lacked consistency in providing explanations that aligned with scientific and medical consensus. Although GPT-4 shows promise, current LLMs are not sufficiently advanced to answer anesthesiology board examination questions with passing success. Further iterations and domain-specific training may enhance their utility in medical education.


Assuntos
Anestesiologia , Humanos , Inteligência Artificial , Estudos Prospectivos , Reprodutibilidade dos Testes , Idioma
6.
J Cardiothorac Vasc Anesth ; 38(10): 2176-2183, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38955619

RESUMO

OBJECTIVE: To describe the development and implementation of a comprehensive in situ simulation-based curriculum for anesthesia residents. DESIGN: This is a prospective study. SETTING: This study was conducted at a university hospital. PARTICIPANTS: This single-center prospective study included all 53 anesthesia residents enrolled in the anesthesia residency program. INTERVENTIONS: Introduction of a routine, high-fidelity, in situ simulation program that incorporates short sessions to train residents in the necessary skill sets and decision-making processes required in the operating room. MEASUREMENTS AND MAIN RESULTS: Our team conducted 182 individual 15-minute simulation sessions over 3 months during regular working hours. All 53 residents in our program actively participated in the simulations. Most residents engaged in at least 3 sessions, with an average participation rate of 3.4 per resident (range, 1-6 sessions). Residents completed an online anonymous survey, with a response rate of 71.7% (38 of 53 residents) over the 3-month period. The survey aimed to assess their overall impression and perceived contribution of this project to their training. CONCLUSIONS: Our proposed teaching method can bridge the gap in resident training and enhance their critical reasoning to manage diverse clinical situations they may not experience during their residency.


Assuntos
Anestesiologia , Competência Clínica , Currículo , Internato e Residência , Internato e Residência/métodos , Humanos , Estudos Prospectivos , Anestesiologia/educação , Treinamento por Simulação/métodos , Tomada de Decisão Clínica/métodos , Tomada de Decisões , Masculino
7.
J Cardiothorac Vasc Anesth ; 38(10): 2187-2197, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39048413

RESUMO

OBJECTIVES: This study assess the feasibility of integrating virtual reality (VR) simulation into the central venous catheter (CVC) placement training curriculum. DESIGN: The study consists of 3 parts: (1) Evaluating current manikin-based training for CVC placement through surveys for senior first-year anesthesia residents and cardiac anesthesia faculty who supervise resident performing the procedure; (2) Interventional study training novice trainees with VR simulator and assessing their reaction satisfaction; and (3) pilot study integrating VR training sessions into CVC training curriculum for first-year anesthesia residents. SETTING: Conducted at a single academic-affiliated medical center from December 2022 to August 2023. PARTICIPANTS: Junior first-year anesthesia residents. INTERVENTIONS: VR training sessions for CVC placements using the Vantari VR system. MEASUREMENTS AND MAIN RESULTS: Primary outcome: novice trainees' satisfaction with VR training for CVC procedure. Satisfaction of resident and faculty with standard manikin-based training was also collected. Faculty expressed concerns about residents' confidence and perceived knowledge in performing CVC placement independently. Novice trainees showed high satisfaction and perceived usefulness with VR training, particularly in understanding procedural steps and developing spatial awareness. Pilot integration of VR training into the curriculum demonstrated comparable training times and emphasized structured stepwise training modules to ensure completion of vital procedural steps. CONCLUSIONS: This study underscores the potential of VR simulation as a complementary training tool for CVC placement rather than a substitution of standard manikin training. VR is offering immersive experiences and addressing limitations of traditional manikin-based training methods. The integration of VR into training curricula warrants further exploration to optimize procedural proficiency and patient safety in clinical practice.


Assuntos
Cateterismo Venoso Central , Competência Clínica , Currículo , Estudos de Viabilidade , Internato e Residência , Realidade Virtual , Humanos , Cateterismo Venoso Central/métodos , Internato e Residência/métodos , Anestesiologia/educação , Projetos Piloto , Cateteres Venosos Centrais , Treinamento por Simulação/métodos , Masculino , Manequins , Feminino , Educação de Pós-Graduação em Medicina/métodos
8.
J Vasc Surg ; 77(5): 1542-1552.e9, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36243265

RESUMO

OBJECTIVE: Postoperative morbidity in patients undergoing lower extremity amputation (LEA) has remained high. Studies investigating the influence of the anesthetic modality on the postoperative outcomes have yielded conflicting results. The aim of our study was to assess the effects of regional anesthesia vs general anesthesia on postoperative complications for patients undergoing LEA. METHODS: We systematically searched PubMed, Embase, MEDLINE, Web of Science, and Google Scholar from 1990 to 2022 for studies investigating the effect of the anesthetic modality on the postoperative outcomes after LEA. Regional anesthesia (RA) included neuraxial anesthesia and peripheral nerve blocks. The outcomes included 30-day mortality, respiratory failure (unplanned postoperative intubation, failure to wean, mechanical ventilation >24 hours), surgical site infection, cardiac complications, urinary tract infection, renal failure, sepsis, venous thrombosis, pneumonia, and myocardial infarction. RESULTS: Of the 25 studies identified, we included 10 retrospective observational studies with 81,736 patients, of whom 69,754 (85.3%) had received general anesthesia (GA) and 11,980 (14.7%) had received RA. In the GA group, 50,468 patients were men (63.8%), and in the RA group, 7813 patients were men (62.3%). The results of the meta-analyses revealed that GA was associated with a higher rate of respiratory failure (odds ratio, 1.38; 95% confidence interval, 1.06-1.80; P = .02) and sepsis (odds ratio, 1.21; 95% confidence interval, 1.11-1.33; P < .0001) compared with RA. No differences were found in postoperative 30-day mortality, surgical site infection, cardiac complications, urinary tract infection, renal failure, venous thrombosis, pneumonia, and myocardial infarction between the GA and RA groups. CONCLUSIONS: The results of our meta-analysis have shown that GA could be associated with a higher rate of respiratory failure and sepsis compared with RA for LEA.


Assuntos
Anestesia por Condução , Infarto do Miocárdio , Pneumonia , Insuficiência Respiratória , Masculino , Humanos , Feminino , Infecção da Ferida Cirúrgica , Estudos Retrospectivos , Resultado do Tratamento , Anestesia por Condução/efeitos adversos , Amputação Cirúrgica/efeitos adversos , Pneumonia/complicações , Anestesia Geral/efeitos adversos , Extremidade Inferior/cirurgia , Insuficiência Respiratória/complicações , Complicações Pós-Operatórias/etiologia
9.
Echocardiography ; 40(8): 750-759, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37002823

RESUMO

OBJECTIVE: Demonstrate that regional geometric differences exist between regurgitant and non-regurgitant mitral valves (MV's) in patients with coronary artery disease and due to the heterogenous and regional nature of ischemic remodeling in patients with coronary artery disease (CAD), that the available anatomical reserve and likelihood of developing mitral regurgitation (MR) is variable in non-regurgitant MV's in patients with CAD. METHODS: In this retrospective, observational study intraoperative three-dimensional transesophageal echocardiographic data was analyzed in patients undergoing coronary revascularization with MR (IMR group) and without MR (NMR group). Regional geometric differences between both groups were assessed and MV reserve which was defined as the increase in antero-posterior (AP) annular diameter from baseline that would lead to coaptation failure was calculated in three zones of the MV from antero-lateral (zone 1), middle (zone 2), and posteromedial (zone 3). MEASUREMENTS AND MAIN RESULTS: There were 31 patients in the IMR group and 93 patients in the NMR group. Multiple regional geometric differences existed between both groups. Most significantly patients in the NMR group had significantly larger coaptation length and MV reserve than the IMR group in zones 1 (p-value = .005, .049) and 2 (p-value = .00, .00), comparable between the two groups in zone 3 (p-value = .436, .513). Depletion of the MV reserve was associated with posterior displacement of the coaptation point in zones 2 and 3. CONCLUSIONS: There are significant regional geometric differences between regurgitant and non-regurgitant MV's in patients with coronary artery disease. Due to regional variations in available anatomical reserve and the risk of coaptation failure in patients with CAD, absence of MR is not synonymous with normal MV function.


Assuntos
Doença da Artéria Coronariana , Insuficiência da Valva Mitral , Isquemia Miocárdica , Humanos , Valva Mitral/cirurgia , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Estudos Retrospectivos
10.
J Cardiothorac Vasc Anesth ; 37(6): 1026-1031, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36878817

RESUMO

Simulation-based training plays an essential role in transesophageal echocardiography (TEE) education. Using 3-dimensional printing technology, the authors invented a novel TEE teaching system consisting of a series of heart models that can be segmented according to actual TEE views, and an ultrasound omniplane simulator to demonstrate how ultrasound beams intersect the heart at different angles and generate images. This novel teaching system is able to provide a more direct way to visualize the mechanics of obtaining TEE images than traditional online or mannequin-based simulators. It can also provide tangible feedback of both an ultrasound scan plane and a TEE view of the heart, which has been proven to improve trainees' spatial awareness and can significantly help in understanding and memorizing complex anatomic structures. This teaching system itself is also portable and inexpensive, making it conducive to teaching TEE in regions of diverse economic status. This teaching system also can be expected to be used for just-in-time training in a variety of clinical scenarios, including operating rooms, intensive care units, etc.


Assuntos
Ecocardiografia Tridimensional , Treinamento por Simulação , Humanos , Ecocardiografia Transesofagiana/métodos , Coração , Manequins , Unidades de Terapia Intensiva
11.
J Cardiothorac Vasc Anesth ; 37(10): 2090-2097, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37422335

RESUMO

Invasive procedures are associated with adverse events that are both hazardous to patients and expensive to treat. A trainee is expected to perform complex sterile invasive procedures in a dynamic environment under time pressure while maintaining patient safety at the highest standard of care. For mastery in performing an invasive procedure, the automatism of the technical aspects is required, as well as the ability to adapt to patient conditions, anatomic variability, and environmental stressors. Virtual reality (VR) simulation training is an immersive technology with immense potential for medical training, potentially enhancing clinical proficiency and improving patient safety. Virtual reality can project near-realistic environments onto a head-mounted display, allowing users to simulate and interact with various scenarios. Virtual reality has been used extensively for task training in various healthcare-related disciplines and other fields, such as the military. These scenarios often incorporate haptic feedback for the simulation of physical touch and audio and visual stimuli. In this manuscript, the authors have presented a historical review, the current status, and the potential application of VR simulation training for invasive procedures. They specifically explore a VR training module for central venous access as a prototype for invasive procedure training to describe the advantages and limitations of this evolving technology.


Assuntos
Treinamento por Simulação , Realidade Virtual , Humanos , Simulação por Computador , Treinamento por Simulação/métodos
12.
J Cardiothorac Vasc Anesth ; 37(6): 988-999, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36870792

RESUMO

Transseptal puncture is an increasingly common procedure undertaken to gain access to the left side of the heart during structural heart disease interventions. Precision guidance during this procedure is paramount to ensure success and patient safety. As such, multimodality imaging, such as echocardiography, fluoroscopy, and fusion imaging, is routinely used to guide safe transseptal puncture. Despite the use of multimodal imaging, there is currently no uniform nomenclature of cardiac anatomy between the various imaging modes and proceduralists, and echocardiographers tend to use imaging modality-specific terminology when communicating among the various imaging modes. This variability in nomenclature among imaging modes stems from differing anatomic descriptions of cardiac anatomy. Given the required level of precision in performing transseptal puncture, a clearer understanding of the basis of cardiac anatomic nomenclature is required by both echocardiographers as well as proceduralists; enhanced understanding can help facilitate communication across specialties and possibly improve communication and safety. In this review, the authors highlight the variation in cardiac anatomy nomenclature among various imaging modes.


Assuntos
Septo Interatrial , Ablação por Cateter , Cardiopatias , Humanos , Cateterismo Cardíaco/métodos , Septo Interatrial/diagnóstico por imagem , Septo Interatrial/cirurgia , Ecocardiografia/métodos , Punções/métodos
13.
J Cardiothorac Vasc Anesth ; 37(7): 1088-1094, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37062664

RESUMO

The clinical utility of transesophageal echocardiography (TEE) is well-established for patients undergoing cardiac surgery. With the increase in percutaneous structural heart disease procedures that rely on TEE for procedural guidance, the use of TEE probes is expanding. Although there are well-established protocols for routine cleaning and decontaminating TEE probes between patient use, there is a lack of awareness and misconceptions about maintaining TEE probes' structural and electrical integrity. The electrical leakage test (ELT) is routinely performed between patient use. From a patient safety standpoint, the ELT is necessary to ensure the longevity of this expensive equipment and prevent disruptions to the workflow in a busy department caused by TEE probes being decommissioned due to probe damage. This technical communication aims to highlight the importance of maintaining TEE probes' structural and electrical integrity. The article also highlights and discusses probe handling techniques between patient use, emphasizing the ELT to ensure patient safety and compliance with national and international standards.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ecocardiografia Transesofagiana , Humanos , Ecocardiografia Transesofagiana/métodos
14.
J Cardiothorac Vasc Anesth ; 37(9): 1813-1818, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37296022

RESUMO

Simulation-based training is an essential component in the education of transthoracic echocardiography (TTE). Nevertheless, current TTE teaching methods may be subject to certain limitations. Hence, the authors in this study aimed to invent a novel TTE training system employing three-dimensional (3D) printing technology to teach the basic principles and psychomotor skills of TTE imaging more intuitively and understandably. This training system comprises a 3D-printed ultrasound probe simulator and a sliceable heart model. The probe simulator incorporates a linear laser generator to enable the visualization of the projection of the ultrasound scan plane in a 3D space. By using the probe simulator in conjunction with the sliceable heart model or other commercially available anatomic models, trainees can attain a more comprehensive understanding of probe motion and related scan planes in TTE. Notably, the 3D-printed models are portable and low-cost, suggesting their potential utility in various clinical scenarios, particularly for just-in-time training.


Assuntos
Ecocardiografia , Coração , Humanos , Ecocardiografia/métodos , Ultrassonografia , Coração/diagnóstico por imagem , Modelos Anatômicos , Impressão Tridimensional
15.
J Cardiothorac Vasc Anesth ; 37(1): 8-15, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36357306

RESUMO

OBJECTIVES: Ischemic remodeling of the left ventricle in patients with coronary artery disease (CAD) results in geometric changes of the mitral valve (MV) apparatus, leading to reduced MV leaflet coaptation. Although the calculation of the coaptation area has value in assessing the effects of left ventricular remodeling on the MV, it is difficult and time-consuming to measure. In this study the authors hypothesized that the tenting volume (TV) would have a greater association with coaptation area than tenting height (TH) or tenting area (TA). DESIGN: A retrospective review. SETTING: A single tertiary-care academic hospital. PARTICIPANTS: There were 145 adult patients who underwent coronary artery bypass graft surgery between April 2018 and July 2020. MEASUREMENTS AND MAIN RESULTS: Intraoperative 2- and 3-dimensional transesophageal echocardiographic studies were obtained in the precardiopulmonary bypass period. Offline analysis was used to obtain TH, TA, TV and coaptation area for each patient. Correlation between the coaptation area and the TH, TA, and TV was conducted using Pearson's correlation. The median age of the population was 68.0 years (61.0-73.3), the body mass index was 29.0 kg/m2 (25.7-33.5), and 17.8% were females. Increases in TV were the most reliable predictor of decreases in coaptation area (R2 = 0.75) followed by TA (R2 = 0.48) and TH (R2 = 0.47). CONCLUSION: As a representative of the complete topography of the MV, the authors' study demonstrated that in patients with CAD, TV has a greater negative correlation with coaptation area as compared to TH or TA.


Assuntos
Doença da Artéria Coronariana , Ecocardiografia Tridimensional , Insuficiência da Valva Mitral , Adulto , Feminino , Humanos , Idoso , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Remodelação Ventricular , Isquemia
16.
J Cardiothorac Vasc Anesth ; 37(3): 382-391, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36517332

RESUMO

OBJECTIVE: Packed red blood cell transfusion during coronary artery bypass graft surgery is known to be associated with adverse outcomes. However, the association of the timing between transfusions in relation to discharge and 30-day postoperative outcomes has not been studied. The study authors investigated the impact of transfusion timing on 30-day surgical outcomes. DESIGN: A retrospective review. SETTING: At a single tertiary-care academic hospital. PARTICIPANTS: A total of 2,481 adult patients underwent primary coronary artery bypass graft surgery between January 2014 and December 2020. MEASUREMENTS AND MAIN RESULTS: The relationship between the timing of packed red blood cell transfusion (intraoperative, postoperative, or both) and 30-day postoperative outcome variables was calculated as an odds ratio. The influence of timing of transfusion on adjusted probability of postoperative complications was plotted against the lowest intraoperative hematocrit. The median age of the population was 67 years (60.0-74.0), body mass index was 28.5 (25.6-32.3) kg/m2, and 497 (20.0%) were female. A total of 1,588 (36%) patients received packed red blood cell transfusions; 182 (7.3%) received intraoperative transfusions, 489 (19.7%) received postoperative transfusions, and 222 (9.0%) received both (intraoperative and postoperative transfusions). Postoperative transfusion was associated with significantly higher odds of readmission (1.83 [1.32-2.54], p = 0.002) and heart failure (1.64 [1.2-2.23], p = 0.008) compared to patients with no transfusions; whereas intraoperative transfusions were not. CONCLUSION: The authors' data suggested that the postoperative timing of transfusion in patients undergoing coronary artery bypass graft surgery may be associated with an increased incidence of 30-day heart failure and readmission. Prospective research is needed to conclusively confirm these findings.


Assuntos
Transfusão de Sangue , Insuficiência Cardíaca , Adulto , Humanos , Feminino , Idoso , Masculino , Estudos Prospectivos , Ponte de Artéria Coronária/efeitos adversos , Transfusão de Eritrócitos/efeitos adversos , Insuficiência Cardíaca/etiologia
17.
J Cardiothorac Vasc Anesth ; 37(11): 2194-2203, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37316432

RESUMO

Transcatheter edge-to-edge repair (TEER) of the mitral valve is a complex procedure requiring continuous image guidance with 2-dimensional and 3-dimensional transesophageal echocardiography. In this context, the role of the echocardiographer is of paramount importance. Training in interventional echocardiography for procedures such as TEER requires comprehending the complicated workflow of the hybrid operating room and advanced imaging skills that go beyond traditional echocardiography training to guide the procedure. Despite TEER being more commonly performed, the training structure for interventional echocardiographers is lagging, with many practitioners not having any formal training in image guidance for this procedure. In this context, novel training strategies must be developed to increase exposure and aid training. In this review, the authors present a step-wise approach to training for image guidance during TEER of the mitral valve. The authors have deconstructed this complex procedure into modular components and have incremental stages of training based on different steps of the procedure. At each step, trainees must demonstrate proficiency before advancing to the next step, thus ensuring a more structured approach to attaining proficiency in this complex procedure.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Cateterismo Cardíaco/métodos , Ecocardiografia , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento
18.
Ann Vasc Surg ; 84: 239-249, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35247532

RESUMO

BACKGROUND: While cross-clamp site is a known risk factor for postoperative acute and chronic renal dysfunction following open abdominal aortic aneurysm surgery (AAA), the additive impact of patient demographic and clinical factors is lacking. In this study, we investigated the impact of body mass index (BMI), surgical duration and aneurysm diameter on the association between proximal cross-clamp location and postoperative renal dysfunction. METHODS: In this study, we conducted a retrospective analysis of 4,197 patients undergoing open AAA surgery between 2011 and 2018 using data housed in the American College of Surgeons National Safety Quality Improvement Program (ACS-NSQIP) database. The primary outcome was renal dysfunction, which was defined as patients requiring dialysis within 30 days or patients with ≥2 mg/dL rise in creatinine from baseline. We assessed the incidence of renal dysfunction with regard to clamp location and subsequently used multivariable logistic regression to assess clinical and demographic factors associated with renal dysfunction. We used a regression model to plot the association of BMI, surgical duration, and aneurysm diameter with an adjusted probability of postoperative acute and chronic renal dysfunction for individual cross-clamp locations. RESULTS: Of the 4,197 patients analyzed, 405 patients (9.6%) developed renal dysfunction within 30 days with 287 patients requiring dialysis. Patients with supraceliac clamp location had the highest incidence of renal dysfunction (20.4%). Our data showed a significant association of renal dysfunction with higher BMI patients [OR 1.04 (1.02, 1.07), P = 0.001], longer operative times [OR1.01 (1.01, 1.02), P < 0.001], clamp location between the superior mesenteric artery (SMA) and renal artery [OR 1.80 (1.17, 2.78), P = 0.007] and supraceliac clamp location [OR 2.47 (1.62, 3.76), P < 0.001]. CONCLUSIONS: The incidence of renal dysfunction increases with suprarenal clamps. Patients with higher BMI, longer operative times, and increasing aneurysm diameter, and a suprarenal clamp have a significantly increased risk of renal dysfunction compared to those who also had a suprarenal clamp but lower BMI, shorter operative times and smaller aneurysm diameter.


Assuntos
Aneurisma da Aorta Abdominal , Nefropatias , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Humanos , Incidência , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
19.
Echocardiography ; 39(8): 1146-1148, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35819102

RESUMO

INTRODUCTION: Subaortic membrane is an uncommon cause of left ventricular outflow tract obstruction. DISCUSSION: Whereas traditionally described of as a membrane, it is in fact a discreet circumferential shelf of raised endocardium in the left ventricular outflow tract, causing a fixed outflow obstruction. The circumferential nature of subaortic membranes is poorly appreciated on 2-dimensional imaging. CONCLUSION: Using a three-dimensional imaging and recently available on-cart rendition techniques of acquired images, we were able to better visualize the true extent of a sub-aortic membrane while also gaining insight into its origin and structure.


Assuntos
Ecocardiografia Tridimensional , Obstrução do Fluxo Ventricular Externo , Aorta , Humanos
20.
J Cardiothorac Vasc Anesth ; 36(7): 2164-2176, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34334319

RESUMO

Intraoperative echocardiography of the mitral valve in the precardiopulmonary bypass period is an integral part of the surgical decision-making process for assessment of suitability for repair. Although there are comprehensive reviews in the literature regarding echocardiographic examination of the mitral valve, the authors present a practical stepwise algorithmic workflow to make objective recommendations. Advances in echocardiography allow for quantitative geometric analyses of the mitral valve, along with precise assessment of the valvular apparatus with three-dimensional echocardiography. In the precardiopulmonary bypass period, echocardiographers are required to diagnose and quantify valvular dysfunction, assess suitability for repair, assist in annuloplasty ring sizing, and determine the success or failure of the surgical procedure. In this manuscript the authors outline an algorithmic approach to intraoperative echocardiography examination using two-dimensional and three-dimensional modalities to objectively analyze mitral valve function and assist in surgical decision-making.


Assuntos
Ecocardiografia Tridimensional , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Ecocardiografia , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA