Stroke ; 55(1): 22-30, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38134268

RESUMO

BACKGROUND: Cerebral cavernous malformation with symptomatic hemorrhage (SH) are targets for novel therapies. A multisite trial-readiness project (https://www.clinicaltrials.gov; Unique identifier: NCT03652181) aimed to identify clinical, imaging, and functional changes in these patients. METHODS: We enrolled adult cerebral cavernous malformation patients from 5 high-volume centers with SH within the prior year and no planned surgery. In addition to clinical and imaging review, we assessed baseline, 1- and 2-year National Institutes of Health Stroke Scale, modified Rankin Scale, European Quality of Life 5D-3 L, and patient-reported outcome-measurement information system, Version 2.0. SH and asymptomatic change rates were adjudicated. Changes in functional scores were assessed as a marker for hemorrhage. RESULTS: One hundred twenty-three, 102, and 69 patients completed baseline, 1- and 2-year clinical assessments, respectively. There were 21 SH during 178.3 patient years of follow-up (11.8% per patient year). At baseline, 62.6% and 95.1% of patients had a modified Rankin Scale score of 1 and National Institutes of Health Stroke Scale score of 0 to 4, respectively, which improved to 75.4% (P=0.03) and 100% (P=0.06) at 2 years. At baseline, 74.8% had at least one abnormal patient-reported outcome-measurement information system, Version 2.0 domain compared with 61.2% at 2 years (P=0.004). The most common abnormal European Quality of Life 5D-3 L domains were pain (48.7%), anxiety (41.5%), and participation in usual activities (41.4%). Patients with prospective SH were more likely than those without SH to display functional decline in sleep, fatigue, and social function patient-reported outcome-measurement information system, Version 2.0 domains at 2 years. Other score changes did not differ significantly between groups at 2 years. The sensitivity of scores as an SH marker remained poor at the time interval assessed. CONCLUSIONS: We report SH rate, functional, and patient-reported outcomes in trial-eligible cerebral cavernous malformation with SH patients. Functional outcomes and patient-reported outcomes generally improved over 2 years. No score change was highly sensitive or specific for SH and could not be used as a primary end point in a trial.


Assuntos
Hemangioma Cavernoso do Sistema Nervoso Central , Acidente Vascular Cerebral , Adulto , Humanos , Hemangioma Cavernoso do Sistema Nervoso Central/complicações , Hemangioma Cavernoso do Sistema Nervoso Central/diagnóstico por imagem , Hemorragia , Estudos Prospectivos , Qualidade de Vida , Acidente Vascular Cerebral/terapia , Resultado do Tratamento
2.
Stroke ; 55(1): 31-39, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38134265

RESUMO

BACKGROUND: Quantitative susceptibility mapping (QSM) and dynamic contrast-enhanced quantitative perfusion (DCEQP) magnetic resonance imaging sequences assessing iron deposition and vascular permeability were previously correlated with new hemorrhage in cerebral cavernous malformations. We assessed their prospective changes in a multisite trial-readiness project. METHODS: Patients with cavernous malformation and symptomatic hemorrhage (SH) in the prior year, without prior or planned lesion resection or irradiation were enrolled. Mean QSM and DCEQP of the SH lesion were acquired at baseline and at 1- and 2-year follow-ups. Sensitivity and specificity of biomarker changes were analyzed in relation to predefined criteria for recurrent SH or asymptomatic change. Sample size calculations for hypothesized therapeutic effects were conducted. RESULTS: We logged 143 QSM and 130 DCEQP paired annual assessments. Annual QSM change was greater in cases with SH than in cases without SH (P=0.019). Annual QSM increase by ≥6% occurred in 7 of 7 cases (100%) with recurrent SH and in 7 of 10 cases (70%) with asymptomatic change during the same epoch and 3.82× more frequently than clinical events. DCEQP change had lower sensitivity for SH and asymptomatic change than QSM change and greater variance. A trial with the smallest sample size would detect a 30% difference in QSM annual change during 2 years of follow-up in 34 or 42 subjects (1 and 2 tailed, respectively); power, 0.8, α=0.05. CONCLUSIONS: Assessment of QSM change is feasible and sensitive to recurrent bleeding in cavernous malformations. Evaluation of an intervention on QSM percent change may be used as a time-averaged difference between 2 arms using a repeated measures analysis. DCEQP change is associated with lesser sensitivity and higher variability than QSM. These results are the basis of an application for certification by the US Food and Drug Administration of QSM as a biomarker of drug effect on bleeding in cavernous malformations. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03652181.


Assuntos
Hemangioma Cavernoso do Sistema Nervoso Central , Hemorragia , Humanos , Estudos Prospectivos , Hemorragia/etiologia , Hemorragia/complicações , Hemangioma Cavernoso do Sistema Nervoso Central/complicações , Hemangioma Cavernoso do Sistema Nervoso Central/diagnóstico por imagem , Hemangioma Cavernoso do Sistema Nervoso Central/patologia , Biomarcadores , Imageamento por Ressonância Magnética/métodos , Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/complicações
3.
Magn Reson Med ; 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38818673

RESUMO

PURPOSE: To study implant lead tip heating because of the RF power deposition by developing mathematical models and comparing them with measurements acquired at 1.5 T and 3 T, especially to predict resonant length. THEORY AND METHODS: A simple exponential model and an adapted transmission line model for the electric field transfer function were developed. A set of wavenumbers, including that calculated from insulated antenna theory (King wavenumber) and that of the embedding medium were considered. Experiments on insulated, capped wires of varying lengths were performed to determine maximum temperature rise under RF exposure. The results are compared with model predictions from analytical expressions derived under the assumption of a constant electric field, and with those numerically calculated from spatially varying, simulated electric fields from body coil transmission. Simple expressions for the resonant length bounded between one-quarter and one-half wavelength are developed based on the roots of transcendental equations. RESULTS: The King wavenumber for both models more closely matched the experimental data with a maximum root mean square error of 9.81°C at 1.5 T and 5.71°C at 3 T compared to other wavenumbers with a maximum root mean square error of 27.52°C at 1.5 T and 22.01°C for 3 T. Resonant length was more accurately predicted compared to values solely based on the embedding medium. CONCLUSION: Analytical expressions were developed for implanted lead heating and resonant lengths under specific assumptions. The value of the wavenumber has a strong effect on the model predictions. Our work could be used to better manage implanted device lead tip heating.

4.
Sensors (Basel) ; 23(9)2023 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-37177534

RESUMO

In blood-oxygen-level-dependent (BOLD)-based resting-state functional (RS-fMRI) studies, usage of multi-echo echo-planar-imaging (ME-EPI) is limited due to unacceptable late echo times when high spatial resolution is used. Equipped with high-performance gradients, the compact 3T MRI system (C3T) enables a three-echo whole-brain ME-EPI protocol with smaller than 2.5 mm isotropic voxel and shorter than 1 s repetition time, as required in landmark fMRI studies. The performance of the ME-EPI was comprehensively evaluated with signal variance reduction and region-of-interest-, seed- and independent-component-analysis-based functional connectivity analyses and compared with a counterpart of single-echo EPI with the shortest TR possible. Through the multi-echo combination, the thermal noise level is reduced. Functional connectivity, as well as signal intensity, are recovered in the medial orbital sulcus and anterior transverse collateral sulcus in ME-EPI. It is demonstrated that ME-EPI provides superior sensitivity and accuracy for detecting functional connectivity and/or brain networks in comparison with single-echo EPI. In conclusion, the high-performance gradient enabled high-spatial-temporal resolution ME-EPI would be the method of choice for RS-fMRI study on the C3T.


Assuntos
Mapeamento Encefálico , Imagem Ecoplanar , Imagem Ecoplanar/métodos , Mapeamento Encefálico/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem
5.
J Magn Reson Imaging ; 55(1): 166-175, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34184362

RESUMO

BACKGROUND: A low-cryogen, compact 3T (C3T) MRI scanner with high-performance gradients capable of simultaneously achieving 80 mT/m gradient amplitude and 700 T/m/second slew rate has been in use to study research patients since March 2016 but has not been implemented in the clinical practice. PURPOSE: To compare head MRI examinations obtained with the C3T system and a conventional whole-body 3T (WB3T) scanner in seven parameters across five commonly used brain imaging sequences. STUDY TYPE: Prospective. SUBJECTS: Thirty patients with a clinically indicated head MRI. SEQUENCE: 3T; T1 FLAIR, T1 MP-RAGE, 3D T2 FLAIR, T2 FSE, and DWI. ASSESSMENT: All patients tolerated the scans well. Three board-certified neuroradiologists scored the comparative quality of C3T and WB3T images in blinded fashion using a five-point Likert scale in terms of: signal-to-noise ratio, lesion conspicuity, motion artifact, gray/white matter contrast, cerebellar folia, susceptibility artifact, and overall quality. STATISTICAL TEST: Left-sided, right-sided, and two-sided Wilcoxon signed rank test; Fisher's method. A P value <0.05 was considered statistically significant. RESULTS: The C3T system performed better than the WB3T in virtually all comparisons, except for motion artifacts for the T1 FLAIR and T1 MP-RAGE sequences, where the WB3T system was deemed better. When combining all sequences together, the C3T system outperformed the WB3T system in all image quality parameters evaluated, except for motion artifact (P = 0.13). DATA CONCLUSION: The C3T scanner provided better overall image quality for all sequences, and performed better in all individual categories, except for motion artifact on the T1 FLAIR and T1 MP-RAGE. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 1.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Artefatos , Encéfalo/diagnóstico por imagem , Substância Cinzenta , Humanos , Estudos Prospectivos
6.
J Magn Reson Imaging ; 56(3): 917-927, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35133061

RESUMO

BACKGROUND: Localized regions of left-right image intensity asymmetry (LRIA) were incidentally observed on T2 -weighted (T2 -w) and T1 -weighted (T1 -w) diagnostic magnetic resonance imaging (MRI) images. Suspicion of herpes encephalitis resulted in unnecessary follow-up imaging. A nonbiological imaging artifact that can lead to diagnostic uncertainty was identified. PURPOSE: To investigate whether systematic LRIA exist for a range of scanner models and to determine if LRIA can introduce diagnostic uncertainty. STUDY TYPE: A retrospective study using the Alzheimer's Disease Neuroimaging Initiative (ADNI) data base. SUBJECTS: One thousand seven hundred fifty-three (median age: 72, males/females: 878/875) unique participants with longitudinal data were included. FIELD STRENGTH: 3T. SEQUENCES: T1 -w three-dimensional inversion-recovery spoiled gradient-echo (IR-SPGR) or magnetization-prepared rapid gradient-echo (MP-RAGE) and T2 -w fluid-attenuated inversion recovery (FLAIR) long tau fast spin echo inversion recovery (LT-FSE-IR). Only General Electric, Philips, and Siemens' product sequences were used. ASSESSMENT: LRIA was calculated as the left-right percent difference with respect to the mean intensity from automated anatomical atlas segmented regions. Three neuroradiologists with 37 (**), 32 (**), and 3 (**) years of experience rated the clinical impact of 30 T2 -w three-dimensional FLAIR exams with LRIA to determine the diagnostic uncertainty. Statistical comparisons between retrospective intensity normalized T1 m and original T1 -w images were made. STATISTICAL TESTS: For each image type, a linear mixed effects model was fit using LRIA scores from all scanners, regions, and participants as the outcome and age and sex as predictors. Statistical significance was defined as having a P-value <0.05. RESULTS: LRIA scores were significantly different from zero on most scanners. All clinicians were uncertain or recommended definite diagnostic follow-up in 62.5% of cases with LRIA >10%. Individuals with acute brain pathology or focal neurologic deficits are not enrolled in ADNI; therefore, focal signal abnormalities were considered false positives. DATA CONCLUSION: LRIA is system specific, systematic, creates diagnostic uncertainty, and impacts IR-SPGR, MP-RAGE, and LT-FSE-IR product sequences. LEVEL OF EVIDENCE: 2 Technical Efficacy Stage: 3.


Assuntos
Doença de Alzheimer , Imageamento por Ressonância Magnética , Idoso , Doença de Alzheimer/diagnóstico por imagem , Feminino , Humanos , Modelos Lineares , Imageamento por Ressonância Magnética/métodos , Masculino , Estudos Retrospectivos
7.
J Acoust Soc Am ; 151(3): 1913, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35364910

RESUMO

Standard clinical protocols require hearing protection during magnetic resonance imaging (MRI) for patient safety. This investigation prospectively evaluated the auditory function impact of acoustic noise exposure during a 3.0T MRI in healthy adults. Twenty-nine participants with normal hearing underwent a comprehensive audiologic assessment before and immediately following a clinically indicated head MRI. Appropriate hearing protection with earplugs (and pads) was used per standard of practice. To characterize noise hazards, current sound monitoring tools were used to measure levels of pulse sequences measured. A third audiologic test was performed if a significant threshold shift (STS) was identified at the second test, within 30 days post MRI. Some sequences produced high levels (up to 114.5 dBA; 129 dB peak SPL) that required hearing protection but did not exceed 100% daily noise dose. One participant exhibited an STS in the frequency region most highly associated with noise-induced hearing loss. No participants experienced OSHA-defined STS in either ear. Overall, OAE measures did not show evidence of changes in cochlear function after MRI. In conclusion, hearing threshold shifts associated with hearing loss or OAE level shifts reflecting underlying cochlear damage were not detected in any of the 3.0T MRI study participants who used the current recommended hearing protection.


Assuntos
Surdez , Perda Auditiva Provocada por Ruído , Dispositivos de Proteção das Orelhas , Audição , Perda Auditiva Provocada por Ruído/etiologia , Perda Auditiva Provocada por Ruído/prevenção & controle , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Adulto Jovem
8.
Radiology ; 298(3): 640-651, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33464181

RESUMO

Background Proton density fat fraction (PDFF) estimated by using chemical shift-encoded (CSE) MRI is an accepted imaging biomarker of hepatic steatosis. This work aims to promote standardized use of CSE MRI to estimate PDFF. Purpose To assess the accuracy of CSE MRI methods for estimating PDFF by determining the linearity and range of bias observed in a phantom. Materials and Methods In this prospective study, a commercial phantom with 12 vials of known PDFF values were shipped across nine U.S. centers. The phantom underwent 160 independent MRI examinations on 27 1.5-T and 3.0-T systems from three vendors. Two three-dimensional CSE MRI protocols with minimal T1 bias were included: vendor and standardized. Each vendor's confounder-corrected complex or hybrid magnitude-complex based reconstruction algorithm was used to generate PDFF maps in both protocols. The Siemens reconstruction required a configuration change to correct for water-fat swaps in the phantom. The MRI PDFF values were compared with the known PDFF values by using linear regression with mixed-effects modeling. The 95% CIs were calculated for the regression slope (ie, proportional bias) and intercept (ie, constant bias) and compared with the null hypothesis (slope = 1, intercept = 0). Results Pooled regression slope for estimated PDFF values versus phantom-derived reference PDFF values was 0.97 (95% CI: 0.96, 0.98) in the biologically relevant 0%-47.5% PDFF range. The corresponding pooled intercept was -0.27% (95% CI: -0.50%, -0.05%). Across vendors, slope ranges were 0.86-1.02 (vendor protocols) and 0.97-1.0 (standardized protocol) at 1.5 T and 0.91-1.01 (vendor protocols) and 0.87-1.01 (standardized protocol) at 3.0 T. The intercept ranges (absolute PDFF percentage) were -0.65% to 0.18% (vendor protocols) and -0.69% to -0.17% (standardized protocol) at 1.5 T and -0.48% to 0.10% (vendor protocols) and -0.78% to -0.21% (standardized protocol) at 3.0 T. Conclusion Proton density fat fraction estimation derived from three-dimensional chemical shift-encoded MRI in a commercial phantom was accurate across vendors, imaging centers, and field strengths, with use of the vendors' product acquisition and reconstruction software. © RSNA, 2021 See also the editorial by Dyke in this issue.


Assuntos
Fígado Gorduroso/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Algoritmos , Biomarcadores , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Estudos Prospectivos , Prótons , Reprodutibilidade dos Testes , Estados Unidos
9.
Magn Reson Med ; 86(1): 69-81, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33565112

RESUMO

PURPOSE: Chemical shift-encoded MRI (CSE-MRI) is well-established to quantify proton density fat fraction (PDFF) as a quantitative biomarker of hepatic steatosis. However, temperature is known to bias PDFF estimation in phantom studies. In this study, strategies were developed and evaluated to correct for the effects of temperature on PDFF estimation through simulations, temperature-controlled experiments, and a multi-center, multi-vendor phantom study. THEORY AND METHODS: A technical solution that assumes and automatically estimates a uniform, global temperature throughout the phantom is proposed. Computer simulations modeled the effect of temperature on PDFF estimation using magnitude-, complex-, and hybrid-based CSE-MRI methods. Phantom experiments were performed to assess the temperature correction on PDFF estimation at controlled phantom temperatures. To assess the temperature correction method on a larger scale, the proposed method was applied to data acquired as part of a nine-site multi-vendor phantom study and compared to temperature-corrected PDFF estimation using an a priori guess for ambient room temperature. RESULTS: Simulations and temperature-controlled experiments show that as temperature deviates further from the assumed temperature, PDFF bias increases. Using the proposed correction method and a reasonable a priori guess for ambient temperature, PDFF bias and variability were reduced using magnitude-based CSE-MRI, across MRI systems, field strengths, protocols, and varying phantom temperature. Complex and hybrid methods showed little PDFF bias and variability both before and after correction. CONCLUSION: Correction for temperature reduces temperature-related PDFF bias and variability in phantoms across MRI vendors, sites, field strengths, and protocols for magnitude-based CSE-MRI, even without a priori information about the temperature.


Assuntos
Fígado , Prótons , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes , Temperatura
10.
Magn Reson Med ; 84(1): 192-205, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31799747

RESUMO

PURPOSE: To demonstrate the feasibility of pseudo-continuous arterial-spin-labeled (pCASL) imaging with 3D fast-spin-echo stack-of-spirals on a compact 3T scanner (C3T), to perform trajectory correction for eddy-current-induced deviations in the spiral readout of pCASL imaging, and to assess the correction effect on perfusion-related images with high-performance gradients (80 mT/m, 700T/m/s) of the C3T. METHODS: To track eddy-current-induced artifacts with Archimedean spiral readout, the spiral readout in pCASL imaging was performed with 5 different peak gradient slew rate (Smax ) values ranging from 70 to 500 T/m/s. The trajectory for each Smax was measured using a dynamic field camera and applied in a density-compensated gridding image reconstruction in addition to the nominal trajectory. The effect of the trajectory correction was assessed with perfusion-weighted (ΔM) images and proton-density-weighted images as well as cerebral blood flow (CBF) maps, obtained from 10 healthy volunteers. RESULTS: Blurring artifact on ΔM images was mitigated by the trajectory correction. CBF values on the left and right calcarine cortices showed no significant difference after correction. Also, the signal-to-noise ratio of ΔM images improved, on average, by 7.6% after correction (P < .001). The greatest improvement of 12.1% on ΔM images was achieved with a spiral readout using Smax of 300~400 T/m/s. CONCLUSION: Eddy currents can cause spiral trajectory deviation, which leads to deformation of the CBF map even in cases of low value Smax . The trajectory correction for spiral-readout-based pCASL produces more reliable results for perfusion imaging. These results suggest that pCASL is feasible on C3T with high-performance gradients.


Assuntos
Imageamento Tridimensional , Angiografia por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Circulação Cerebrovascular , Humanos , Marcadores de Spin
11.
J Magn Reson Imaging ; 51(1): 296-310, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31111581

RESUMO

BACKGROUND: Distortion-free, high-resolution diffusion imaging using DIADEM (Distortion-free Imaging: A Double Encoding Method), proposed recently, has great potential for clinical applications. However, it can suffer from prolonged scan times and its reliability for quantitative diffusion imaging has not been evaluated. PURPOSE: To investigate the clinical feasibility of DIADEM-based high-resolution diffusion imaging on a novel compact 3T (C3T) by evaluating the reliability of quantitative diffusion measurements and utilizing both the high-performance gradients (80 mT/m, 700 T/m/s) and the sequence optimization with the navigator acquisition window reduction and simultaneous multislice (multiband) imaging. STUDY TYPE: Prospective feasibility study. PHANTOM/SUBJECTS: Diffusion quality control phantom scans to evaluate the reliability of quantitative diffusion measurements; 36 normal control scans for B0 -field mapping; six healthy and two patient subject scans with a brain tumor for comparisons of diffusion and anatomical imaging. FIELD STRENGTH/SEQUENCE: 3T; the standard single-shot echo-planar-imaging (EPI), multishot DIADEM diffusion, and anatomical (2D-FSE [fast-spin-echo], 2D-FLAIR [fluid-attenuated-inversion-recovery], and 3D-MPRAGE [magnetization prepared rapid acquisition gradient echo]) imaging. ASSESSMENT: The scan time reduction, the reliability of quantitative diffusion measurements, and the clinical efficacy for high-resolution diffusion imaging in healthy control and brain tumor volunteers. STATISTICAL TEST: Bland-Altman analysis. RESULTS: The scan time for high in-plane (0.86 mm2 ) resolution, distortion-free, and whole brain diffusion imaging were reduced from 10 to 5 minutes with the sequence optimizations. All of the mean apparent diffusion coefficient (ADC) values in phantom were within the 95% confidence interval in the Bland-Altman plot. The proposed acquisition with a total off-resonance coverage of 597.2 Hz wider than the expected bandwidth of 500 Hz in human brain could yield a distortion-free image without foldover artifacts. Compared with EPI, therefore, this approach allowed direct image matching with the anatomical images and enabled improved delineation of the tumor boundaries. DATA CONCLUSION: The proposed high-resolution diffusion imaging approach is clinically feasible on C3T due to a combination of hardware and sequence improvements. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 1 J. Magn. Reson. Imaging 2020;51:296-310.


Assuntos
Encéfalo/anatomia & histologia , Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Imagem Ecoplanar , Estudos de Viabilidade , Humanos , Imagens de Fantasmas , Estudos Prospectivos , Reprodutibilidade dos Testes
12.
J Magn Reson Imaging ; 51(4): 1192-1199, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31515878

RESUMO

BACKGROUND: Quantitative susceptibility mapping (QSM) and dynamic contrast-enhanced quantitative permeability (DCEQP) on magnetic resonance (MR) have been shown to correlate with neurovascular disease progression as markers of vascular leakage and hemosiderin deposition. Applying these techniques as monitoring biomarkers in clinical trials will be necessary; however, their validation across multiple MR platforms and institutions has not been rigorously verified. PURPOSE: To validate quantitative measurement of MR biomarkers on multiple instruments at different institutions. STUDY TYPE: Phantom validation between platforms and institutions. PHANTOM MODEL: T1 /susceptibility phantom, two-compartment dynamic flow phantom. FIELD STRENGTH/SEQUENCE: 3T/QSM, T1 mapping, dynamic 2D SPGR. ASSESSMENT: Philips Ingenia, Siemens Prisma, and Siemens Skyra at three different institutions were assessed. A QSM phantom with concentrations of gadolinium, corresponding to magnetic susceptibilities of 0, 0.1, 0.2, 0.4, and 0.8 ppm was assayed. DCEQP was assessed by measuring a MultiHance bolus as the consistency of the width ratio of the curves at the input and outputs over a range of flow ratios between outputs. STATISTICAL TESTS: Each biomarker was assessed by measures of accuracy (Pearson correlation), precision (paired t-test between repeated measurements), and reproducibility (analysis of covariance [ANCOVA] between instruments). RESULTS: QSM accuracy of r2 > 0.997 on all three platforms was measured. Precision (P = 0.66 Achieva, P = 0.76 Prisma, P = 0.69 Skyra) and reproducibility (P = 0.89) were good. T1 mapping of accuracy was r2 > 0.98. No significant difference between width ratio regression slopes at site 2 (P = 0.669) or site 3 (P = 0.305), and no significant difference between width ratio regression slopes between sites was detected by ANCOVA (P = 0.48). DATA CONCLUSION: The phantom performed as expected and determined that MR measures of QSM and DCEQP are accurate and consistent across repeated measurements and between platforms. LEVEL OF EVIDENCE: 1 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2020;51:1192-1199.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Permeabilidade , Imagens de Fantasmas , Reprodutibilidade dos Testes
13.
Magn Reson Med ; 79(4): 2024-2035, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28833440

RESUMO

PURPOSE: To develop a fully automated trajectory and gradient waveform design for the non-Cartesian shells acquisition, and to develop a magnetization-prepared (MP) shells acquisition to achieve an efficient three-dimensional acquisition with improved gray-to-white brain matter contrast. METHODS: After reviewing the shells k-space trajectory, a novel, fully automated trajectory design is developed that allows for gradient waveforms to be automatically generated for specified acquisition parameters. Designs for two types of shells are introduced, including fully sampled and undersampled/accelerated shells. Using those designs, an MP-Shells acquisition is developed by adjusting the acquisition order of shells interleaves to synchronize the center of k-space sampling with the peak of desired gray-to-white matter contrast. The feasibility of the proposed design and MP-Shells is demonstrated using simulation, phantom, and volunteer subject experiments, and the performance of MP-Shells is compared with a clinical Cartesian magnetization-prepared rapid gradient echo acquisition. RESULTS: Initial experiments show that MP-Shells produces excellent image quality with higher data acquisition efficiency and improved gray-to-white matter contrast-to-noise ratio (by 36%) compared with the conventional Cartesian magnetization-prepared rapid gradient echo acquisition. CONCLUSION: We demonstrated the feasibility of a three-dimensional MP-Shells acquisition and an automated trajectory design to achieve an efficient acquisition with improved gray-to-white matter contrast. Magn Reson Med 79:2024-2035, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Encéfalo/diagnóstico por imagem , Substância Cinzenta/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética , Magnetismo , Substância Branca/diagnóstico por imagem , Algoritmos , Automação , Meios de Contraste , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Software
14.
Magn Reson Med ; 79(6): 2902-2911, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-28971512

RESUMO

PURPOSE: To investigate the feasibility of substantially reducing acoustic noise while performing diffusion tensor imaging (DTI) on a compact 3T (C3T) MRI scanner equipped with a 42-cm inner-diameter asymmetric gradient. METHODS: A-weighted acoustic measurements were made using 10 mT/m-amplitude sinusoidal waveforms, corresponding to echo-planar imaging (EPI) echo spacing of 0.25 to 5.0 ms, on a conventional, whole-body 3T MRI and on the C3T. Acoustic measurements of DTI with trapezoidal EPI waveforms were then made at peak gradient performance on the C3T (80 mT/m amplitude, 700 T/m/s slew rate) and at derated performance (33 mT/m, 10 to 50 T/m/s) for acoustic noise reduction. DTI was acquired in two different phantoms and in seven human subjects, with and without gradient-derating corresponding to multi- and single-shot acquisitions, respectively. RESULTS: Sinusoidal waveforms on the C3T were quieter by 8.5 to 15.6 A-weighted decibels (dBA) on average as compared to the whole-body MRI. The derated multishot DTI acquisition noise level was only 8.7 dBA (at 13 T/m/s slew rate) above ambient, and was quieter than non-derated, single-shot DTI by 22.3 dBA; however, the scan time was almost quadrupled. Although derating resulted in negligible diffusivity differences in the phantoms, small biases in diffusivity measurements were observed in human subjects (apparent diffusion coefficient = +9.3 ± 8.8%, fractional anisotropy = +3.2 ± 11.2%, radial diffusivity = +9.4 ± 16.8%, parallel diffusivity = +10.3 ± 8.4%). CONCLUSION: The feasibility of achieving reduced acoustic noise levels with whole-brain DTI on the C3T MRI was demonstrated. Magn Reson Med 79:2902-2911, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem de Tensor de Difusão , Acústica , Adulto , Anisotropia , Encéfalo/diagnóstico por imagem , Imagem Ecoplanar , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Ruído , Imagens de Fantasmas , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Temperatura , Adulto Jovem
15.
Magn Reson Med ; 79(3): 1538-1544, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28639370

RESUMO

PURPOSE: Imaging gradients result in the generation of concomitant fields, or Maxwell fields, which are of increasing importance at higher gradient amplitudes. These time-varying fields cause additional phase accumulation, which must be compensated for to avoid image artifacts. In the case of gradient systems employing symmetric design, the concomitant fields are well described with second-order spatial variation. Gradient systems employing asymmetric design additionally generate concomitant fields with global (zeroth-order or B0 ) and linear (first-order) spatial dependence. METHODS: This work demonstrates a general solution to eliminate the zeroth-order concomitant field by applying the correct B0 frequency shift in real time to counteract the concomitant fields. Results are demonstrated for phase contrast, spiral, echo-planar imaging (EPI), and fast spin-echo imaging. RESULTS: A global phase offset is reduced in the phase-contrast exam, and blurring is virtually eliminated in spiral images. The bulk image shift in the phase-encode direction is compensated for in EPI, whereas signal loss, ghosting, and blurring are corrected in the fast-spin echo images. CONCLUSION: A user-transparent method to compensate the zeroth-order concomitant field term by center frequency shifting is proposed and implemented. This solution allows all the existing pulse sequences-both product and research-to be retained without any modifications. Magn Reson Med 79:1538-1544, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Humanos , Processamento de Sinais Assistido por Computador , Punho/diagnóstico por imagem
16.
Magn Reson Med ; 79(3): 1354-1364, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28643408

RESUMO

PURPOSE: To investigate the effect of the asymmetric gradient concomitant fields (CF) with zeroth and first-order spatial dependence on fast/turbo spin-echo acquisitions, and to demonstrate the effectiveness of their real-time compensation. METHODS: After briefly reviewing the CF produced by asymmetric gradients, the effects of the additional zeroth and first-order CFs on these systems are investigated using extended-phase graph simulations. Phantom and in vivo experiments are performed to corroborate the simulation. Experiments are performed before and after the real-time compensations using frequency tracking and gradient pre-emphasis to demonstrate their effectiveness in correcting the additional CFs. The interaction between the CFs and prescan-based correction to compensate for eddy currents is also investigated. RESULTS: It is demonstrated that, unlike the second-order CFs on conventional gradients, the additional zeroth/first-order CFs on asymmetric gradients cause substantial signal loss and dark banding in fast spin-echo acquisitions within a typical brain-scan field of view. They can confound the prescan correction for eddy currents and degrade image quality. Performing real-time compensation successfully eliminates the artifacts. CONCLUSIONS: We demonstrate that the zeroth/first-order CFs specific to asymmetric gradients can cause substantial artifacts, including signal loss and dark bands for brain imaging. These effects can be corrected using real-time compensation. Magn Reson Med 79:1354-1364, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Artefatos , Encéfalo/diagnóstico por imagem , Simulação por Computador , Humanos , Imagens de Fantasmas
17.
Magn Reson Med ; 80(5): 2232-2245, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29536587

RESUMO

PURPOSE: To build and evaluate a small-footprint, lightweight, high-performance 3T MRI scanner for advanced brain imaging with image quality that is equal to or better than conventional whole-body clinical 3T MRI scanners, while achieving substantial reductions in installation costs. METHODS: A conduction-cooled magnet was developed that uses less than 12 liters of liquid helium in a gas-charged sealed system, and standard NbTi wire, and weighs approximately 2000 kg. A 42-cm inner-diameter gradient coil with asymmetric transverse axes was developed to provide patient access for head and extremity exams, while minimizing magnet-gradient interactions that adversely affect image quality. The gradient coil was designed to achieve simultaneous operation of 80-mT/m peak gradient amplitude at a slew rate of 700 T/m/s on each gradient axis using readily available 1-MVA gradient drivers. RESULTS: In a comparison of anatomical imaging in 16 patients using T2 -weighted 3D fluid-attenuated inversion recovery (FLAIR) between the compact 3T and whole-body 3T, image quality was assessed as equivalent to or better across several metrics. The ability to fully use a high slew rate of 700 T/m/s simultaneously with 80-mT/m maximum gradient amplitude resulted in improvements in image quality across EPI, DWI, and anatomical imaging of the brain. CONCLUSIONS: The compact 3T MRI system has been in continuous operation at the Mayo Clinic since March 2016. To date, over 200 patient studies have been completed, including 96 comparison studies with a clinical 3T whole-body MRI. The increased gradient performance has reliably resulted in consistently improved image quality.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Imagem Corporal Total/instrumentação , Encéfalo/diagnóstico por imagem , Desenho de Equipamento , Feminino , Humanos , Imageamento Tridimensional , Imãs , Masculino , Imagens de Fantasmas , Razão Sinal-Ruído
18.
J Magn Reson Imaging ; 48(6): 1498-1507, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30255963

RESUMO

BACKGROUND: Gradient nonlinearity (GNL) leads to biased apparent diffusion coefficients (ADCs) in diffusion-weighted imaging. A gradient nonlinearity correction (GNLC) method has been developed for whole body systems, but is yet to be tested for the new compact 3T (C3T) scanner, which exhibits more complex GNL due to its asymmetrical design. PURPOSE: To assess the improvement of ADC quantification with GNLC for the C3T scanner. STUDY TYPE: Phantom measurements and retrospective analysis of patient data. PHANTOM/SUBJECTS: A diffusion quality control phantom with vials containing 0-30% polyvinylpyrrolidone in water was used. For in vivo data, 12 patient exams were analyzed (median age, 33). FIELD STRENGTH/SEQUENCE: Imaging was performed on the C3T and two commercial 3T scanners. A clinical DWI (repetition time [TR] = 10,000 msec, echo time [TE] = minimum, b = 1000 s/mm2 ) sequence was used for phantom imaging and 10 patient cases and a clinical DTI (TR = 6000-10,000 msec, TE = minimum, b = 1000 s/mm2 ) sequence was used for two patient cases. ASSESSMENT: The 0% vial was measured along three orthogonal axes, and at two different temperatures. The ADC for each concentration was compared between the C3T and two whole-body scanners. Cerebrospinal fluid and white matter ADCs were quantified for each patient and compared to values in literature. STATISTICAL TESTS: Paired t-test and two-way analysis of variance (ANOVA). RESULTS: For all PVP concentrations, the corrected ADC was within 2.5% of the reference ADC. On average, the ADC of cerebrospinal fluid and white matter post-GNLC were within 1% and 6%, respectively, of values reported in the literature and were significantly different from the uncorrected data (P < 0.05). DATA CONCLUSION: This study demonstrated that GNL effects were more severe for the C3T due to the asymmetric gradient design, but our implementation of a GNLC compensated for these effects, resulting in ADC values that are in good agreement with values from the literature. LEVEL OF EVIDENCE: 4 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;48:1498-1507.


Assuntos
Imagem de Difusão por Ressonância Magnética , Processamento de Imagem Assistida por Computador/métodos , Adolescente , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Dinâmica não Linear , Imagens de Fantasmas , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
19.
Neuroimage ; 158: 26-36, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28666879

RESUMO

Functional magnetic resonance imaging (fMRI) is an emerging tool for investigating brain activation associated with, or modulated by, deep brain stimulation (DBS). However, DBS-fMRI generally suffers from severe susceptibility to artifacts in regions near the metallic stimulation electrodes, as well as near tissue/air boundaries of the brain. These result in strong intensity and geometric distortions along the phase-encoding (PE) (i.e., blipped) direction in gradient-echo echo-planar imaging (GE-EPI). Distortion presents a major challenge to conducting reliable data analysis and in interpreting the findings. A recent study showed that the point spread function (PSF) mapping-based reverse gradient approach has a potential to correct for distortions not only in spin-echo EPI, but also in GE-EPI acquired in both the forward and reverse PE directions. In this study, we adapted that approach in order to minimize severe metal-induced susceptibility artifacts for DBS-fMRI, and to evaluate the performance of the approach in a phantom study and a large animal DBS-fMRI study. The method combines the distortion-corrected GE-EPI pair with geometrically different intensity distortions due to the opposing encoding directions. The results demonstrate that the approach can minimize susceptibility artifacts that appear around the metallic electrodes, as well as in the regions near the tissue/air boundaries in the brain. We also demonstrated that an accurate geometric correction is important in improving BOLD contrast in the group dataset, especially in regions where strong susceptibility artifacts appear.


Assuntos
Artefatos , Estimulação Encefálica Profunda/métodos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Animais , Encéfalo/fisiologia , Eletrodos Implantados , Humanos , Processamento de Imagem Assistida por Computador , Metais , Suínos
20.
Magn Reson Med ; 77(2): 774-778, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-26888162

RESUMO

PURPOSE: Relaxation time constants are useful as markers of tissue properties. Imaging ex vivo tissue is done for research purposes; however, T1 relaxation time constants are altered by tissue fixation in a time-dependent manner. This study investigates regional changes in T1 relaxation time constants in ex vivo brain tissue over 6 months of fixation. METHODS: Five ex vivo human brain hemispheres in 10% formalin were scanned over 6 months. Mean T1 relaxation time constants were measured in regions of interest (ROIs) representing gray matter (GM) and white matter (WM) regions and analyzed as a function of fixation time. RESULTS: Cortical GM ROIs had longer T1 relaxation time constants than WM ROIs; the thalamus had T1 relaxation time constants similar to those of WM ROIs. T1 relaxation time constants showed rapid shortening within the first 6 weeks after fixation followed by a slower rate of decline. CONCLUSION: Both GM and WM T1 relaxation time constants of fixed brain tissue show rapid decline within the first 6 weeks after autopsy and slow by 6 months. This information is useful for optimizing MR imaging acquisition parameters according to fixation time for ex vivo brain imaging studies. Magn Reson Med 77:774-778, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.


Assuntos
Encéfalo/diagnóstico por imagem , Fixadores , Formaldeído , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Idoso de 80 Anos ou mais , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA