Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Obes Rev ; 21(8): e13041, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32374499

RESUMO

Accurate measurement of body composition is required to improve health outcomes in children and adolescents with overweight or obesity. This systematic review aimed to summarize the reliability and validity of field and laboratory body composition techniques employed in pediatric obesity studies to facilitate technique selection for research and clinical practice implementation. A systematic search in MEDLINE (via PubMed), EMBASE, CINAHL, and SPORTDiscus from inception up to December 2019 was conducted, using a combination of the following concepts: body composition, pediatric overweight/obesity, and reliability/validity. The search strategy resulted in 66 eligible articles reporting reliability (19.7%), agreement between body composition techniques cross sectionally (80.3%), and/or diagnostic test accuracy (10.6%) in children and adolescents with overweight or obesity (mean age range = 7.0-16.5 years). Skinfolds, air-displacement plethysmography (ADP), dual-energy X-ray absorptiometry (DXA), and ultrasound presented as reliable techniques. DXA, ADP, and isotope dilution showed similar and the best agreement with reference standards. Compared with these laboratory techniques, the validity of estimating body composition by anthropometric equations, skinfolds, and BIA was inferior. In conclusion, the assessment of body composition by laboratory techniques cannot be replaced by field techniques due to introduction of measurement errors, which potentially conceal actual changes in body components.


Assuntos
Antropometria/métodos , Composição Corporal/fisiologia , Obesidade Infantil/fisiopatologia , Absorciometria de Fóton , Criança , Humanos , Pletismografia , Reprodutibilidade dos Testes
2.
Obesity (Silver Spring) ; 21(3): 546-52, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23592662

RESUMO

OBJECTIVE: High body fat (BF) is an alarming condition that also affects nondialyzed chronic kidney disease (CKD) patients. Distinct methods are used to evaluate BF; however, in CKD population it remains unclear which one is more reliable showing high accuracy. Dual-energy X-ray absorptiometry (DXA), used as reference method to estimate adiposity, is expensive and time consuming to be applied in clinical settings. Recently, a new body adiposity index (BAI), that estimates BF from easily accessible measures, was validated in the general population. The aim of this study was to evaluate which simple and practical method, routinely used to estimate BF, shows the highest accuracy compared with DXA, in nondialyzed CKD patients. DESIGN AND METHODS: In this cross-sectional study BF was estimated by DXA, bioelectrical impedance analysis (BIA), anthropometry (ANTHRO), and BAI. Serum leptin levels were determined. RESULTS: Studied patients (n = 134) were 55% males, 54% overweight/obese, and 64.9 ± 12.5 years old, with estimated glomerular filtration rate (eGFR) = 29.0 ± 12.7 ml/min. The correlation coefficient was higher between DXA vs. ANTHRO (r = 0.76) and BAI (r = 0.61) than with BIA (r = 0.57), after adjusting for gender, age, and eGFR (P < 0.0001). Therefore, the Lin's concordance correlation coefficient and Bland-Altman plots were performed to measure the accuracy (C_b) between DXA with both ANTHRO and BAI. A higher accuracy (C_b = 0.82) and lower mean difference (-3.4%) was observed for BAI than for ANTHRO (C_b = 0.61; -8.4%). Leptin levels correlated (P < 0.0001) with DXA (r = 0.56) and BAI (r = 0.59). CONCLUSIONS: These findings suggest that BAI estimates BF with high accuracy in nondialyzed CKD patients and may be helpful in the treatment of this population with increased BF.


Assuntos
Tecido Adiposo , Adiposidade , Sobrepeso/fisiopatologia , Insuficiência Renal Crônica/fisiopatologia , Absorciometria de Fóton , Idoso , Antropometria , Biomarcadores/sangue , Índice de Massa Corporal , Estudos Transversais , Impedância Elétrica , Estudos de Avaliação como Assunto , Feminino , Humanos , Leptina/sangue , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Obesidade/fisiopatologia , Sobrepeso/complicações , Insuficiência Renal Crônica/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA